CARRIER HVACPRODUCT GUIDE

PD 2/4/2014 | v 1.3Pricing shown is in U.S. DollarsPricing subject to change without notice

1HVAC Distribution Product Guide

Table of Contents

Mated ERVs ...........................................................................................2OA Hood Economizer Systems ...........................................................3Hood and Duct Part Numbering ..........................................................3Hood and Duct Packages/Options ......................................................4Economizer Systems ........................................................................5-6Sensors .................................................................................................7Accessories .......................................................................................8-9Notes....................................................................................................10RTU Reference Guide.........................................................................11

iAIRE, LLC6805 Hillsdale Court

Indianapolis, IN 46250

www.act-solutions.com | 800-886-2281

2HVAC Distribution Product Guide

MATED ERVs

MATED ERV PART NUMBERING SCHEME

PLEASE NOTE: It is assumed that the RTU fan is running at 400 CFM/Ton (i.e. If the RTU is a 6 ton unit, the RTU fan is running at 2,400 CFM).

Min OA ERV is sized for 33% of the total fan capacity of the RTU (i.e. If the ERV is mated to a 6 ton unit, the ERV would be sized for 800 CFM).

The IAQ ERV is sized to handle the same amount of outside air as the Min OA ERV, but uses the iAIRE patent pending technol-ogy to reduce the size of the ERV wheel.

Both the Min OA ERV and the IAQ ERV come standard with the following accessories: Built in economizer damper, Controller that controls both the ERV and economizer, VOC sensor, CO2 sensor, two (2) temperature probes (outside air and supply air), variable quantity of ionization devices sized to handle the airflow of the RTU.

EMsize

A - IAQ LOWB - IAQ STDC - IAQ HIGHD - MIN OA LOWE - MIN OA STDF - MIN OA HIGH

unit/tonCHAS1 - Chassis 1CHAS2 - Chassis 2CHAS3 - Chassis 3CHAS4 - Chassis 4CHAS5 - Chassis 5CHAS67 - Chassis 6/7CHAS89 - Chassis 8/9

voltage control0 - ELECTRO MECHA - IAQ

options0 - NO OPTIONSC - BUILDING PRESSD - FROST PROTECTE - HUMIDITY SENSF - BACNETK - HORZ RA RTU

maintenanceindicator

0 - NO INDICATORSA - DIRT FILT INDIC

disconnect0 - NO DISCONNECTA - 240 V NON FUSEDB - 240 V FUSEDC - 600 V NON FUSEDD - 600 V FUSED

wheelA - TOTL ENTHLPYB - SENSIBLE ONLYC - PURGE

3HVAC Distribution Product Guide

HD * * - * - * *

package0 - NO PACKAGEA - IAQB - DCVC - ECOND - CO2 DIRECT CNTRL

accessory0 - NONEC - MODULAT DMPER

unit/ton

CHAS1CHAS2CHAS3CHAS4CHAS5CHAS67CHAS891010 - 10x10 DUCT2020 - 20x20 DUCT

options0 - NO OPTIONSA - HUM / ENTHB - BACNETC - AIRFLOW MON.D - LL DAMPER

sizeA - RTU OA HDB - RTU ECON HDC - DUCTD - ERV IAQ OA HDE - ERV IAQ EX HDF - ERV MINOA OA HDG - ERV MINOA EX HD

OA HOOD ECONOMIZER SYSTEMS

OA HOOD WITH ECONOMIZER PACKAGE PART NUMBER

OUTSIDE AIR HOOD ECONOMIZER PACKAGEFor units that have a modulating damper, the unit is equipped with a damper and modulating actuator on it. You need to have a modulating damper to pick any of the package options in digit 4.

*Contact factory for additional duct sizes

21 3 4 5

AIRFLOW HOODS AND DUCTS All flow hood and duct units have airflow sensing technology built into the package so units read accurately once installed.

All units also have the ability to change standard economizer controllers to CFM based control systems and can bring CFM points out to BACnet.

All units eligible for LEED credit with CFM output and a low CFM alarm point.

ERV HOODS All ERV hoods must be ordered when ordering the ERV. Hoods for the ERV can only add the airflow option as the ERV will include package and accessory components based on ERV ordered.

4HVAC Distribution Product Guide

HOOD AND DUCT PACKAGES/OPTIONSThe base airflow monitoring hood or duct (selected in the 4th and 8th digit of the part number) has airflow sensing technology built into the package so units read accurately once installed. They have the ability to change standard economizer controllers to CFM based control systems and can bring CFM points out to BACnet.

When you add a modulating damper (selected in the 4th digit of the part number), a modulating damper will be added to the hood. A controls package should be selected (8th digit of the part number) to control the damper. The packages are as follows:

IAQ (A) - Supplied with controller, VOC sensor, CO2 sensor, temperature probes (2) and ionization devices. This will allow you to monitor CFM through the hood and will reduce our OA with the iAIRE patent pending process. DCV (B) - Supplied with controller, CO2 sensor and temperature probes (2). This will allow you to monitor CFM through the hood while controlling the damper based on CFM.

ECON (C) - Supplied with controller and temperature probes (2). This will allow you to monitor CFM through the hood while controlling the damper to a set CFM position.

CO2 DIRECT CONTROL (D) - Supplied with CO2 sensor. This will allow for output from the CO2 sensor directly to the modulating damper to control the damper.

Options that come with the airflow hoods and ducts are as follows:

HUM / ENTH (A) - For use when converting any of the packages from dry bulb to wet bulb or enthalpy control of the damper.

BACNET (B) - For use when translating values from the system and sending them out to BACnet.

5HVAC Distribution Product Guide

ECONOMIZER SYSTEMSIAQ CONTROLS PACKAGEThe iAIRE IAQ controls packages come with the items and quantity outlined below. These packages will allow you to reduce the amount of outside air needed by up to 2/3 and will improve your indoor air quality. This system is set up to go directly on an existing economizer or OA hood that has a modulating damper. The packages are a lower cost alternative to buying each part individually.

Ionizationair cleaner

mod. # ION-0A*00

6HVAC Distribution Product Guide

ECONOMIZER SYSTEMSCONTROLLERThe iAIRE economizer controller is used to control the economizer actuator and all sensors to achieve outdoor air savings and clean air unlike any other system before.

PART NUMBERSIAIRE-1000

BACnet TRANSLATORThe iAIRE BACNet translator provides reliable protocol translation for your system.

PART NUMBERSTRANS-AE-001 (Econ & ERV board)TRANS-AH-001 (Hood)

7HVAC Distribution Product Guide

SENSORS

TEMPERATURE PROBEiAIRE’s 10K, type 2, NTC temperature transmitters are a cost effective solution for all of your temperature measurement needs. The transmitters are accurate, durable, and reliable.

PART NUMBERSTP-B-0-J-02-72-A

HUMIDITY SENSORiAIRE’s humidity sensors are great for high end HVAC, clean rooms, green houses and other locations needing to measure temperature and humidity. It also offers the ability to determine enthalpy in HVAC systems. 0-10V or 4-20mA output.

PART NUMBERSSEN-HUM-A-02-02-0

VOC SENSORThe iAIRE VOC sensor is a versatile product and can be mounted to any standard wall. It is designed for VOC detection and should not be used as a safety detector (for example, a gas alert detector). 0-10V or 4-20mA output.

PART NUMBERSSEN-VOC-A-01-01-0

CO2 SENSORThe iAIRE CO2 detector provides real-time CO2 levels and is designed for basic application in HVAC and ventilation systems applications. 0-10V or 4-20mA output.

PART NUMBERSSEN-CO2-B-01-01-0

BUILDING PRESSURE SENSORThe iAIRE building pressure sensor offers low-pressure measurement for building energy management and comfort control. 0 - 0.25” w.c.

PART NUMBERSSEN-DP-C-01-03-0

8HVAC Distribution Product Guide

ACCESSORIES20 IN-LB ACTUATORiAIRE’s low torque actuator works on small dampers, economizer units, residential zoning equipment as well as terminal units.

PART NUMBERSMTR-0002

62 IN-LB ACTUATORiAIRE’s medium torque actuator works on outside air dampers, mixing boxes, small rooftop units, return air dampers, zone isolation dampers and economizer units.

PART NUMBERSMTR-0003

160 IN-LB ACTUATORiAIRE’s high torque actuator works on outside air dampers, mixing boxes, rooftop units, return air dampers, zone isolation dampers and vortex dampers.

PART NUMBERSMTR-0004

ACTUATOR FLOOR MOUNTMounting kit allows for foot mounting of the actuator. Mounting should be used for in-the-air stream applications or other acceptable location for foot mounting.

PART NUMBERSMTR-0006

ACTUATOR FRAME MOUNTMounting kit allows for direct mounting of actuator to the damper frame. Should be used with louvers and vents as well as when floor mounting is not permitted.

PART NUMBERSMTR-0007

9HVAC Distribution Product Guide

ACCESSORIESACTUATOR WALL MOUNTMounting kit allows for economical mounting of the actuator to a variety of surfaces. Mount should be used where the actuator can be rigidly mounted and a linear stroke output is required.

PART NUMBERSMTR-0008

MOUNTING PLATEThe iAIRE mounting plate offers easy mounting when you have multiple ion air cleaners for your system. It is located near the inlet to the HVAC supply blower so ion air cleaners can mount easily and provide optimized ion coverage.

PART NUMBERSUNV0016

24V TRANSFORMERThe iAIRE transformer is to be used when additional power is needed on your rooftop unit to support the ionization air cleaner system. 75KV with built in circuit breaker.

PART NUMBERSTRN-0002

10HVAC Distribution Product Guide

NOTES

11Carrier Branded Units

CARRIER BRYANT ICPCHASSIS

CLASSIFICATION UNIT PART NUMBER UNIT PART NUMBER UNIT PART NUMBER

CHASSIS 1

48/50TC 04-06; 50TCQ 04-05; 48/50HC,LC 04; 50HCQ 04;48/50 TF,TM 004-007; 48TJ 004-007; 48HJ 004-006; 50TJ 004-006;50HJ,HJQ 004-006

580J,558J 04-06; 548J 04-05; 581,551J 04; 549J 04

PAH,PGH,RAS,RGS 036-060;RHS 036-048; RAH,RGH,RHH 036;PAE 036-072; PAS,PGE,PGS,PHS 072

CHASSIS 2

48/50TC 07; 50TCQ 06-07; 48/50HC,LC 05-06;50HCQ 05-06; 48HJ 007;50TJ 007

580J, 558J 07; 548J 06-07;581J, 551J 05-06; 549J 05-06

PAH,PGH,RAS,RGS 072; RAH,RGH,RHH 048-060;RHS 060-072

CHASSIS 3

48/50TC 08; 48/50HC 07; 50HCQ 07;48/50 TJ,TF,TM 008-009;48/50 HJ 008

580J,558J 08; 581J,551J 07; 549J 07 PAH,RAS,PGS,PHS 090;RAS,RGS 090-091;RAH,RGH,RHH 072;PGE,PAE 090-102

CHASSIS 4

48/50LC 07; 48/50HC 08-12; 48/50HCQ 08-09;48/50TC 09-14; 50TCQ 08-12;48/50 TJ,TF,TM 012-014;48/50 HJ 009-014

580J,548J 09-14; 548J 08-12; 581J,551J 08-12; 549J 08-09

PAH, PGH 102-120;RAS, RGS 102-150;RHS,RAH,RGH 090-120; RHH 090-102;PAE,PAS,PGE,PGS 120-150; PHS 120

CHASSIS 5

48/50TC 16; 50TCQ 14;48/50HC 14; 50HCQ 12;48/50LC 08-12

580J,558J 16; 548J 14;581J,551J 14; 549J 12

RAS,RGS 180; RHS,RGH 150;RHH 120

CHASSIS 6

48/50LC 14; 48/50HC 17;48/50TC 17-20; 48/50TCQ 17

580J, 558J 17-20; 548J 17 RAS,RGS 210/213;RHS,RAH,RGH 181/183

CHASSIS 7

48/50HC 20; 48/50TC 24;48/50TCQ 24

580J, 558J, 548J 24 RAS,RHS,RGSS 240/243;RAH,RGH 210/213

CHASSIS 8

48/50LC 17-20; 48/50HC 24; 48/50TC 28

580J, 558J 28 RAS,RGS 300/303;RAH,RGH 240/243

CHASSIS 9

48/50LC 24-26; 48/50HC 28; 48/50TC 30

580J, 558J 30 RAS,RGS 336/333;RAH,RGH 300/303

CARRIER CHASSIS REFERENCE GUIDEAll units listed below reference units manufactured after the year 2000 Carrier design change. Please contact the factory for units manufactured before 2000.