carolinas chapter/american association of clinical endocrinologists 2016 … · 2016-09-01 ·...

53
CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION September 9-11, 2016 ~ Sonesta Resort ~ Hilton Head Island, SC This continuing medical education activity is jointly provided by the Carolinas Chapter, AACE and Southern Regional Area Health Education Center 8.25 CME Credits!

Upload: others

Post on 18-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS

2016 Annual MeetingHILTON HEAD ISLAND

FRIDAY PRESENTATIONSeptember 9-11, 2016 ~ Sonesta Resort ~ Hilton Head Island, SC

This continuing medical education activity is jointly provided by theCarolinas Chapter, AACE and Southern Regional Area Health Education Center

8.25 CME Credits!

Page 2: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

Bruce W. Bode, MD, FACEAtlanta Diabetes AssociatesAssociate Professor of Medicine, Emory UniversityAtlanta, Georgia

Artificial Pancreas Systems

Page 3: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

DISCLOSURE STATEMENT

Research and Grant Support to Employer: Abbott, Animas, Biodel,DexCom, GSK, Janssen, JDRF, Lexicon, Lilly/BI, MannKind,Medtronic, NIH, Novo Nordisk, Pfizer, Sanofi, Sensonics Consultant: Abbott, Janssen, Medtronic, Novo Nordisk, Sanofi,

Thermalin, Valeritas Speaker’s Bureau: Astra Zeneca, Janssen, Insulet, Mannkind,

Medtronic, Merck, Novo Nordisk, Sanofi

Page 4: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

STATUS OF TYPE 1 DIABETES CARE IN USA: THERAPY ADVANCES NEEDED

The Type 1 Exchange, n=25,000 subjects, 67 sites2

Not at Goal Excess Hypoglycemia

The average type-1 patient has:• Two symptomatic hypoglycemic events per week1

• One or more episodes of severe, temporally disabling hypoglycemia per year• Nocturnal hypoglycemia occurs ~ 8.5% of nights2

Page 5: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

INSULIN PUMP USE - CURRENT

61% 62% 66%60% 56%

65% 62% 58%

0%

20%

40%

60%

80%

100%

Overall <6 6-12 13-17 18-25 26-49 50-64 ≥65

Age (years)

Page 6: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

58%50%

58% 57% 56%61% 60% 56%

61% 62% 66% 60%56%

65%62% 58%

0%

20%

40%

60%

80%

100%

Overall <6 6-12 13-17 18-25 26-49 50-64 ≥65Age (years)

Enrolled 9/1/2010 - 8/1/2012Current 4/1/2014 - 4/1/2015

INSULIN PUMP USE IS INCREASING

Page 7: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

PUMP MANUFACTURER

Animas 23%

Medtronic 61%

Insulet 11%

Tandem 3%Roche 1%Other 1%

Page 8: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CONTINUOUS GLUCOSE MONITOR USE

12%17%

10%6% 8%

25%21%

14%

0%

10%

20%

30%

40%

50%

Overall <6 6-12 13-17 18-25 26-49 50-64 ≥65Age (years)

Page 9: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CGM USE IS INCREASING BUT STILL LOW

4% 4% 3% 5%

17% 18%

10%

17%

10%6% 8%

25%21%

14%

0%

10%

20%

30%

40%

50%

<6 6-12 13-17 18-25 26-49 50-64 ≥ 65Age (years)

Enrolled 2010-2012 (8% use CGM overall)

Current 2014-2015 (12% use CGM overall)

Page 10: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CGM USE BY INSULIN DELIVERY METHOD

23%

14%9%

12%

32%28%

18%

6%2% 1% 3%

11%10% 9%

0%

10%

20%

30%

40%

50%

<6 6-12 13-17 18-25 26-49 50-64 ≥65

Age (years)

Pump Injection

Page 11: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

LOWER A1C IN INSULIN PUMP USERS

8.7%

9.2%

7.8%

8.2%

8.6%

7.5%

7.0%

7.5%

8.0%

8.5%

9.0%

9.5%

<13 13-25 ≥26

Mea

n H

bA1c

%

Age (years)

Injection Insulin Pump

Page 12: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

LOWER A1C IN CGM USERS

8.4%

8.9%

7.7%7.8%

8.1%

7.3%

7.0%

7.5%

8.0%

8.5%

9.0%

<13 13-25 ≥26

Mea

n H

bA1c

%

Age (years)

Non CGM Users CGM Users

Page 13: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

LOWER A1C IN CGM USERS REGARDLESS OF INSULIN DELIVERY METHOD

8.7

9.3

7.8

8.38.6

7.67.9 8.0

7.2

7.88.1

7.2

7.0%

7.5%

8.0%

8.5%

9.0%

9.5%

<13N=3050

13-<26N=6855

≥26N=4077

Mea

n H

bA1c

%

Age (years)

Injection only Pump only

Injection + CGM Pump + CGM

Page 14: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

LOWER A1C WITH INCREASED SMBG (EXCLUDES CURRENT CGM USERS)

6.5%

7.0%

7.5%

8.0%

8.5%

9.0%

9.5%

10.0%

0-3 4-6 6-9 ≥10

SMBG # Per Day

Pump Injection

Age <18

0-3 4-6 6-9 ≥10SMBG # Per Day

Age ≥18

Page 15: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CURRENT PUMPS ON THE USA MARKET

Page 16: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CONTINUOUS MONITORING SYSTEMS IN USA

Paradigm or Guardian REAL-Time DexCom G5 Platinum

CGMS® iPro™ Recorder

Page 17: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

pump + sensor uploader mobile device any Internet-enabled device

MINIMED CONNECT

For care partners:online access to diabetes information

For healthcare providers: automatic CareLink uploads

For people with diabetes: discreet display of pump and CGM information

A better connection to diabetes care

Page 18: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

Dexcom G5 Mobile

Dexcom Share/Follow

G5 App

Page 19: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CGM Use

0%

20%

40%

60%

80%

Age ≥25 Age 15-24 Age 8-14

Perc

enta

ge o

f sub

ject

s

<4.0 days/week

4.0-<6.0 days/week

≥6.0 days/week

Change in glycated hemoglobin-0.8

-0.6

-0.4

-0.2

0.0

0.2

Cha

nge

in g

lyca

ted

hem

oglo

bin

JDRF CGM Study Group. N Engl J Med 2008; 359:1464-76.

Page 20: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

8.3%

7.3%7.5% 7.5% 7.5%

8.0% 8.0%8.1% 8.1%

7.0%

7.5%

8.0%

8.5%

0 3 6 9 12

Months

A1C

MDT STAR 3 SENSOR-AUGMENTED PUMP TRIAL

Values are means ± SE. Comparisons between SAP group and MDI group are significant for each time period (P<0.001).

The SAP group achieved a greater A1C reduction vs. MDI at 3 months and sustained it over 12 months

A1C Reduction for SAP and MDI Groups

= MDI= SAPn = 244 n = 241

- 0.6P<0.001

∆ -0.2

∆ -0.8

- 0.6P<0.001

Page 21: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

A1C Reduction Correlates to Increased Sensor Use

Values are the difference between the means ± SE. p=0.003 for association between sensor wear and A1C reduction at 1 year. Only 7 participants had sensor use of 20% or less, with a change in A1C of -0.43 at 1 year vs. baseline.

• The majority of patients used sensors ≥61% of the time • Patients who used sensors ≥81% of the time reduced their mean A1C by

1.2% at 1 year vs. baseline

-0.19

-0.64-0.79

-1.21-1.5

-1

-0.5

021-40% 41-60% 61-80% 81-100%

Frequency of Sensor Use (% of Time)

Cha

nge

in A

1C a

t 1 Y

ear v

s B

asel

ine

n =27 n =46 n =108 n =56

Page 22: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

DCCT (Adolescents & Adults)Severe Hypo Rate: 62.0 per 100 pt-yrs,

A1C: 9.0% → 7.2%

STAR 3 SAP (Pediatrics & Adults)Severe Hypo Rate: 13.3 per 100 pt-yrs,

A1C: 8.3% → 7.5%

JDRF CGM (Adults, 1 Subject excluded)Severe Hypo Rate: 20.0 per 100 pt-yrs,

A1C: 7.6% → 7.1%

Nathan et al. The New Engl J Med. 1993; 329(14); Tamborlane et al. The New Engl J Med. 2008;359:1464-1476.:Bergenstal et al. N Engl J Med. doi:10.1056/NEJMoa1002853: Battelino et al. Diabetologia DOI 10.1007/s00125‐012‐2708‐9

SENSOR-AUGMENTED PUMPS IMPROVE A1C WITHOUT INCREASING HYPOGLYCEMIA

Page 23: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

FUNDAMENTALS OF CLOSED-LOOP SYSTEMS

HCL FCLTS PLGM

Subject Burden Automation

Regulatory Ease System Complexity

Page 24: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

FIRST COMMERCIAL STEP IN THE ARTIFICIAL PANCREAS

Threshold Suspend

Page 25: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

EXAMPLE OF THRESHOLD SUSPEND CYCLE

Suspend time maximum = 2 hrs

Insulin infusion stops

Basal insulin infusion will resume even if glucose is below Thresh Suspend limit

Basal Insulin Basal Insulin2 Hour Suspend

Insulin Suspends for 2 hours / Resumes for 4 hours

Automatically suspends insulin delivery if sensor glucose reaches the user-set limit

Page 26: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

Threshold Suspend Manual Suspend(Not represented in above report)

Daily Detail Report

Threshold Suspend in CareLink® Professional

Page 27: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

THRESHOLD SUSPEND: ASPIRE IN-HOME STUDY

nducted with Veo pump that is not FDA approved and not commercially available in the US. Study data and final report have not been submitted to FDA.al RM, Klonoff DC, Garg SK, et al. Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med. 2013;369(3):224-232.

The severity and/or duration of nocturnal hypoglycemic events was lower in the Threshold Suspend Group.

1547 980 1406 1568

37.5% reduction (p<0.001)

Page 28: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

THRESHOLD SUSPEND: ASPIRE IN-HOME STUDY

Hypoglycemic events were less frequent in the Threshold Suspend Group.

nducted with Veo pump that is not FDA approved and not commercially available in the US. Study data and final report have not been submitted to FDA.al RM, Klonoff DC, Garg SK, et al. Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med. 2013;369(3):224-232.

30% reduction (p<0.001)

32% reduction (p<0.001)

Page 29: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

ASPIRE IN-HOME STUDY: RESULTS

∆A1C was similar in the two groups. The 95% CI of the difference in ∆A1C (-0.05, 0.15) did not include the non-inferiority limit of 0.4%.

nducted with Veo pump that is not FDA approved and not commercially available in the US. Study data and final report have not been submitted to FDA.al RM, Klonoff DC, Garg SK, et al. Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med. 2013;369(3):224-232.

Page 30: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

*Measured as sensor glucose values

SmartGuard™ Technology

Protection from lows*

Takes action when patients need it most

√√

630G640G670G

Systems530G

System

MDT PATHWAY TO HYBRID CLOSE LOOP

Page 31: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

PIVOTAL TRIALOF A HYBRIDCLOSED-LOOP SYSTEM (MDT 670G) IN TYPE 1 DIABETES

Page 32: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

INVESTIGATORSName Affiliation and Location

Richard M. Bergenstal, MD International Diabetes CenterMinneapolis, MN

Bruce A. Buckinham, MD Stanford UniversityStanford, CA

Satish Garg, MD Barbara Davis Center for Childhood DiabetesAurora, CO

Stuart A. Weinzimer, MD Yale UniversityNew Haven, CT

Ronald Brazg, MD Rainier Clinical ResearchRenton, WA

Jacob Ilany, MD Sheba Medical CenterTel-Hashomer, Israel

Bruce Bode, MD, FACE Atlanta Diabetes AssociatesAtlanta, GA

Timothy Bailey, MD, FACE AMCR InstituteEscondido, CA

Stacey M. Anderson, MD University of VirginiaCharlottesville, VA

Robert Slover, MD Barbara Davis Center for Childhood DiabetesAurora, CO

John Shin, PhD, MBAScott W. Lee, MDFrancine R. Kaufman, MD

Medtronic plcNorthridge, CA

Page 33: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

BACKGROUND

Pump systems that automatically suspend insulin deliverycan reduce hypoglycemia, but no commercially-availablesystems can increase the insulin delivery rate to prevent ormitigate hyperglycemia.Hybrid closed-loop (HCL) systems can automatically

increase or decrease basal insulin, but boluses require userinput and confirmation.The 670G system was evaluated in a pivotal clinical trial of

adults and adolescents with type 1 diabetes that includedsupervised hotel and 3-month unsupervised home use of thesystem 24 hours per day.

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 34: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

SYSTEM COMPONENTS

The MDT 670G system includedthe new pump platform, closed-loop algorithm, and CGM displayfor the investigational 4th-generation subcutaneous glucosesensor and transmitter. Sensors were calibrated with

readings from theCONTOUR®NEXTLINK bloodglucose meter (not shown).

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 35: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

METHODS

The study was conducted at 10 sites in the US and IsraelPatients had type 1 diabetes for ≥2 yearsA1C <10%, were age 14-21 years old (adolescents) or 22-

75 years old (adults)Using pump therapy for ≥6 months, with or without CGMThe pump was used in open-loop mode during a 2-week

run-in phaseThen the pump was used in closed-loop mode in a 3-month

study phase that included a 6-day, 5-night hotel stay forsupervised activity and frequent venous BG measurements(during one 24 hour period) with a reference instrument (i-STAT)

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 36: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

PARTICIPANTS

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 37: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

STUDY FLOW

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 38: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

COMPARING OPEN LOOP TO HYBRID CLOSED LOOP BETTER GLUCOSE CONTROL AS AUTOMATION ADVANCES

Patient with Diabetes – Open Loop Insulin Delivery System

Patient with Diabetes-Closed Loop Insulin Delivery System

Investigative device not approved for sale or use

Page 39: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

HIGHLIGHTS OF THE 670G SYSTEM

Auto Mode- target set at 120 mg/dl; option to

raise to 150 mg/dl for exercise, etc

- Patients must put carbs in pump to deliver meal insulin

- If sensor glucose is above 300 mg/dl or not working, system is placed into manual mode

- Must troubleshoot the system to get back into Auto Mode

HCP- Can only adjust Insulin to Carb

ratio and Active Insulin Time- During trial, patients upload daily

for 2 weeks then weekly thereafter

Page 40: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

RESULTSMODAL DAY SENSOR (SG) GLUCOSE TRACINGS

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 41: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

RESULTSA1C VALUES ANDPROPORTIONS OF NOCTURNAL VALUES ≤ 50 MG/DL

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 42: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

RESULTSDISTRIBUTION OF A1C VALUES

0%

20%

40%

60%

80%

100%

5 6 7 8 9 10

Cum

ulat

ive P

erce

ntag

e

A1C (%)

Run-InEnd of Study

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 43: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

RESULTSKEY ENDPOINTS

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 44: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

RESULTSNUMBER OF SUBJECTS, ∆ A1C AND ∆ SD AS FUNCTIONS OF STARTING A1C

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 45: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

RESULTSSENSOR ACCURACY AND DISTRIBUTION OF i-STAT AND SG VALUES DURING HOTEL PHASE

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 46: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

DEVICE RELATED ADVERSE EVENTS

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 47: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

STRENGTHS

Multicenter design to evaluate safety Large number of subjects, both adults and adolescents,

using the system for 24 hours/day Three months of unsupervised home use of system Time in target confirmed by reference BG measurements

during hotel stay

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 48: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

LIMITATIONS

Single-arm, nonrandomized design with no pre-specifiedefficacy endpoints

Data quantity imbalance between run-in (2 weeks) andstudy phase (3 months)

Exclusion of subjects with A1C >10%, recent episodes ofsevere hypoglycemia or recent DKA

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 49: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

SUMMARY

Three months of unsupervised at-home use of the HCL system (670G) was safe, with no severe hypoglycemia or DKA.

The 4th-generation sensors were accurate. Compared to the run-in phase, HCL control was associated

with less glycemic variability, more time in the target range, less exposure to hypo- and hyperglycemia, and reductions in A1C.

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 50: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CONCLUSIONS

Hybrid closed-loop insulin delivery can help patients reducehypo- and hyperglycemia and safely achieve ADA-recommended A1C goals.

This study suggests that the 67G HCL system should beconsidered for non-investigational use in adults andadolescents with type 1 diabetes in the home setting.

FDA has approved subjects to remain on the Hybrid ClosedLoop system till approved

FDA approval is under review If approved, hopeful launch in 1st to 2nd quarter 2017

Investigational device, not approved for sale or use.Bergenstal R, et al. Poster presented at the 76th Scientific Sessions of the American Diabetes Association, June 10-14, 2016, New Orleans. LA. P-99.

Page 51: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

MDT ALGORITHMS FOR CLOSED LOOPTHE PATH TO REDUCING PATIENT BURDEN

Path

to C

lose

d Lo

op

Threshold/ Low GlucoseSuspendMiniMed® 530G System and MiniMed 630G System

Predictive Suspend*

Hybrid Closed Loop**

Towards PersonalizedClosed Loop***

Automatically doses insulin with minimal mealtime and exercise inputs from the patient

Suspends delivery when the system predicts a low is approaching

Suspends delivery when a low occurs

Improving interface & meal announcement: small, medium, large meal bolus settings and set meal insulin delivery buttonsPattern recognitionAdditional sensor inputs: Activity, food, heart rate, sleep, free fatty acids Detecting sensor or infusion set failure

Advanced HybridClosed Loop***

Addition of meal detection algorithm, allows for more front-loading of meal insulin and earlier delivery of correction post meal

PID for insulin delivery & MPC for safety

Suspension protocol based on actual values

Suspension protocol w/ predictive algorithm 

PID for delivery MPC for safety, FL for meals

PID, MPC & Fuzzy logic + cognitive computing

Partners / Collaborators:

Current USA

Standard

Next Advancemen

t

*Investigative device not approved for sale in the U.S.** Investigational device, not approved for sale or use***Conceptual device

Page 52: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

THE RACE TO THE CLOSED LOOPHOW THE COMPANIES LINE UP

Group ControllerType

Hormone Time InteractionRequired

Medtronic Next Generation with DreaMed

PID Fuzzy Logic Insulin 24 hour Meals, Exercise

Bigfoot Biomedical Proprietary Algorithm

Insulin 24 hour Meals, Exercise

University of Cambridge

MPC Insulin 24 hour Meals, Exercise

University of Virginia Type ZERO

MPC Insulin 24 hour Meals, Exercise

Boston University MPC Insulin + Glucagon 24 hour Meals, Exercise

Animas MPC:Treat-to-RangeHypo-Hyper Minimizer

Insulin 24 hour Meals, Exercise

Page 53: CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 … · 2016-09-01 · CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting

CONCLUSIONS Closed Loop Technology is evolving quickly HCL technology is a game changer for both both patients and HCPs Studies on cost effectiveness are under development and will start later

this year Progression from Hybrid Closed Loop to fully Closed Loop is undergoing

investigation currently but approval will be in the future