Accurate functional diagnostics - easy to use

CARDIOVIT AT-104 PC

Fast, accurate and easy to use – providing added value for patient and physician

The SCHILLER AT-104 PC diagnostic system is much more than just a software program. It is a data acquisition and management solution that can be installed on our AT-104 PC Touch, on your laptop/PC or in your network.

You can perform, analyse, save and transmit the following measurements:• 12-channelrestingECG• 12-channelexerciseECG• Restingrhythm• 24hor48hABPM(ambulatorybloodpressuremeasure-

ment)• 24hlong-termECG• Spirometry• Ergospirometry

The AT-104 PC offers:• seamless connection to electronic patient records forfasterdigitalworkflowsandinvoicing

• worklistsfordirectaccessviaSEMAtothepatientmasterdata in the Hospital Information System. Therefore, the time-consuming entry of patient data is accelerated and delays in invoicing are reduced.

• diagnosticsafetythankstotheprovenECGanalysissoft-ware.

Unique worldwideIn an emergency, when there is a pro-blem with your computer or in case of a power cut, a 3-channel real-time printout on thermal paper is possible thanks to the integrated rechargeab-le battery.The AT-104 PC can be used as a stand-alone device and is equipped with an integrated rechargeable battery.Thanks to its low weight and handy size,itfitsinanydoctor›sbag.

FlexibleadaptationNo matter how large your practice, clinic or hospital is, when it comes to diagnostic data quality, there can be no compromise.The AT-104 PC offers connectivity to the entire range of cardiological dia-gnostic units that provide you with the clear and reliable data that ensure an accurate diagnosis.There are more options than ever to make use of all your data and to con-siderably simplify your workflows. Dis-play all reports simultaneously to get a complete overview on the diagnostic information.

Export your data to the electronicpatient record, to PACS or to the car-diology informationsystemSEMA® for faster diagnosis and invoicing.This is to make sure that your patient is in the centre of attention, and not paperwork.

CARDIOVIT AT-104 PC

Resting rhythm

Exercise ECGErgospirometryResting ECG

Holter ECG

Spirometry

24 h ABPM

CARDIOVIT AT-104 PC

The Art of Connectivity

Areyoucontemplating investing inanECGmanagementsystem?Noproblemwith theCARDIOVITAT-104 PCdiag-nostic system.

The Art of Connectivity is the key to an advanced ECGtechnology.YouneedaportableECGsystemtoexamineyour patients wherever you are, but you also need to be abletotransfertheECGdata.

Access and safety - both is essential. The AT-104 PC offers a scaleableITplatformtoconfigureadiagnosticsystemthatisdesigned to grow along with your requirements.

Open system structureSCHILLER uses standard communication protocols such as:• Digital imaging and communications in medicine(DICOM)*

• HL7• XML• TCP/IP

The AT-104 PC is compatible with the following operating systems: Windows®XP/Pro,Windows7®Business.

Stand-alone unit or use in a network The system can be used as a stand-alone unit or it can be integrated in a network (LAN) comprising severalwork stations for data acquisition and processing.

Access and compliance with direc-tivesThe AT-104 PC protects your data, sys-tem and investment on multiple levels.• Automatic log-off function and

user management optimises data acquisition, enhances the system availability and increases the safe-ty for your server.

Easy access to informationThe raw data is easily accessible for verificationand reanalysis.Olderpa-tient data can be compared directly on the screen in order to evaluate the patient›s medical condition and toallow clearer clinical decisions.• Thankstothedirectconnectionto

electronic patient records, several cardiacandpulmonaryexamina-tions can be saved in a database, allowing a much quicker review and evaluation.

• The average values that are dis-played offline after the exami-nation increase the accuracy of the evaluation of QRS changes and allow the medical staff to see changesthroughouttheexamina-tion at minute intervals.

* Export of 12-channel resting ECG recordings instandard DICOM waveform object format toPACS systems is available as part of the SCHILLER CommunicationServer(SCS).

CARDIOVIT AT-104 PC

More efficient workflows increase the quality of treatment.

Today›shealthcaresystemrequiresstreamlinedwork-flows.TheAT-104PChelpsyoutreatingmorepatientsmoreefficientlybysimplifyingallstepsoftheprocess.

High patient throughput The direct connection to electronic patient records and diagnostic units allows remote access to patient andexaminationdataforafasterdiagnosis.

• Data canbe exportedas PDF, inCSV format forExcel®, or in XML format. PDF file names can begenerated automatically according to demo-graphic patient data, ensuring consistency with the electronic patient record or with data from the hospital information system.

• DICOM option* for long-term archiving of restingECGdatainPACSsystemsandforthereanalysisinDICOMviewers.

Easy data management and invoicingImproved workflows in the AT-104PC help accelerating administrative processes and preventing errors in the dataacquisition.Moreover,theAT-104PCensuresmoreefficientinvoicing.• Direct connection to electronic

patient records helps reducing errors in the data acquisition, ac-celerates administration tasks and consolidates patient data.

• Integrated data managementallows paperless work environ-ments. The data can be archived on any commercially available PC storage medium or on a server. Searching and archiving record-ings becomes as easy as ABC.Printouts can be obtained on a la-ser or inkjet printer at a later stage at any time.

Improved interconnection between administration and clinical examina-tionThe AT-104 PC can easily be connec-ted to the SEMAcardiology informa-tion system of your hospital for even moreefficientprocesses.

PACS

SEMA/SCS

EPA

Clinic / practice

DICOM*

HL7 / PDF

GDT

CARDIOVIT AT-104 PC

Algorithms that simplify your workflows

The AT-104 PC diagnostic system supports your clinical deci-sions and allows you to stay in touch with your practice and patients much more easily.

Diagnostic supportTheAT-104PCoffersSCHILLER›s industry-leadingdiagnostictools that support you in the decision-making process and therefore lead to quicker diagnoses and improved results.• Expandable: the AT-104 PC can be expanded at any

time to become a pulmonary function test device.• Recognised throughout the world: the SCHILLER mea-

surement and interpretation software for children and adults (optional): The high-quality and dependableautomatic ECG analysis of 12 leads saves you a vastamount of time and offers you a reliable second opinion.

• SerialECGcomparison:expansionoftheSCHILLERmea-surement and interpretation software, allowing the ana-lysis of short- and long-term changes in patient ECGs.SerialECGsprovedtobemostefficientinthedetectionof myocardial infarctions, both for new, asymptomatic myocardial infarctions as well as for acute myocardial infarctions in symptomatic patients. Serial electrocardio-graphy is indispensable when assessing unstable angina pectoris.

• QT dispersion: indicates inhomo-geneity in the ventricular repolari-sation. The greater the QT dispersi-on, the more inhomogeneous the ventricular repolarisation and the greater the risk for sudden cardiac death. QT dispersion analysis can be used as an additional non-inva-sive method.

• Rhythm ECG recording: 12-leadfulldisclosureECGrecording,coll-ectingupto120minutesofdiag-nostic data.

• SCHILLER EXEC exercise ECG.• SCHILLER EXEC plus to record beat-to-beatexerciseECGs.

• Expandable: the AT-104 PC can be expandedatanytimetobecomean ergospirometry measurement device.

• ECG signal quality: the AT-104 PC ensures high data quality with algorithms such as SBS SCHILLERBaseline Filter and SSF SCHILLERSmoothing Filter.

CARDIOVIT AT-104 PC – communicates with other SCHILLER systems

BLOOD PRESSURE

BP-200 plus

CARDIOVIT AT-104 PC – communicates with other SCHILLER systems

HOLTER ECG AMBULATORY BP SPIROMETRY

ERGOSPIROMETRY

DATA MANAGEMENT

MT-100/200 BR-102 plus/MT-300 SP-250/260

AT-104 PC

AT-104 PC Ergo-Spiro

SEMA-200/SEMA light

DESIGN

ED

AN

D M

AN U F A C T U R E D

I N S

WIT

ZE

RLA

ND

DESIGN

ED

AN

D M

A N U F A C T U R E D I N

SW

ITZ

ER

LAND

LT Book für inhouse-Druck

Extra Light für Offset-Druck

Headquarters:SCHILLERAG,Altgasse68,CH-6341Baar,Switzerland,Phone+41417664242,Fax+41417610880,[email protected],www.schiller.ch

AsiaSCHILLER Asia-Pacific / Malaysia52200 Kuala Lumpur, MalaysiaPhone +603 6272 3033Fax +603 6272 [email protected]

AustriaSCHILLER Handelsgesellschaft m.b.H.A-4040 LinzPhone +43 732 709 90 Fax +43 732 757 [email protected]

ChinaAlfred Schiller Medical Equipment Co. Ltd.100015 Beijing, ChinaPhone [email protected]

FranceSCHILLER Médical S.A.S.F-67162 Wissembourg/CedexPhone +33 3 88 63 36 00Fax +33 3 88 94 12 [email protected]

France (distribution France)SCHILLER France S.A.S.F-77600 Bussy St GeorgesPhone +33 1 64 66 50 00Fax +33 1 64 66 50 [email protected]

GermanySCHILLER Medizintechnik GmbHD-85622 Feldkirchen b. MünchenPhone +49 89 62 99 81-0Fax +49 89 62 99 [email protected]

HungarySCHILLER Diamed Ltd.H-1141 BudapestPhone +36 (1) 383-4780 / 460-9491Fax +36 (1) [email protected]

IndiaSCHILLER Healthcare India Pvt. Ltd.Mumbai - 400 001, IndiaPhone +91 22 6152 3333/ 2920 9141Fax +91 22 2920 [email protected]

JapanSCHILLER Japan, Ltd.Hiroshima 734-8551Phone +81 82 250 2055Fax +81 82 253 [email protected]

Croatia Schiller medicinski instrumenti d.o.o.10000 ZagrebPhone +385 1 309 66 59Fax +385 1 309 66 [email protected]

Latin AmericaSCHILLER Latin America, Inc.Doral, Florida 33172Phone +1 954 673 0358Fax +1 786 845 06 [email protected]

PolandSCHILLER Poland Sp. z o.o.PL-02-729 WarszawaPhone +48 22 8432089Fax +48 22 [email protected]

Russia & C.I.S.SCHILLER AG Rep. office125124 Moscow, RussiaPhone +7 (495) 970 11 33Fax +7 (495) 970 11 [email protected]

Serbia SCHILLER d.o.o.11010 BeogradPhone +381 11 39 79 508Fax +381 11 39 79 [email protected]

Slovenia SCHILLER d.o.o.2310 Slovenska BistricaPhone +386 2 843 00 56Fax +386 2 843 00 [email protected]

SpainSCHILLER ESPAÑA, S.A.E-28230-Las Rozas/MadridPhone +34 91 713 01 76Fax +34 91 355 79 [email protected]

SwitzerlandSCHILLER-Reomed AGCH-8953 DietikonPhone +41 44 744 30 00Fax +41 44 740 37 [email protected]

TurkeySCHILLER TÜRKIYEOkmeydani-Sisli – IstanbulPhone +90 212 210 8681 (pbx)Fax +90 212 210 [email protected]

USASCHILLER America Inc.Doral, Florida 33172Phone +1 786 845 0620Fax +1 786 845 06 [email protected]

081/11

Part

no

.: 2.500241*2.500241*