Galvanizing production line on Metallurgy _ CANopen Solution21st Feb, 2013John ZuoIABG EMEA

Page 2: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

TABLE OF CONTENT

Galvanizing Introduction

CANopen Introduction

CANopen Solution based on C2000

Reference Case

FAQ

Appendix

Page 3: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

Galvanizing Introduction

• Galvanization is the process of applying a protective zinc coating to steel or iron, in order to

prevent rusting. The most common method in current use is hot-dip galvanization, in which

steel parts are submerged in a bath of molten zinc.

Page 4: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

CANopen Introduction

• CANopen is the internationally standardized (EN 50325-4) CAN-based higher-layer protocol

for embedded control system. It is used in a very board range of application fields such as

Packaging, Machine Tool, Pharmacy, metallurgy and etc..

CANopen is one popular fieldbus for Industrial Automation.

Page 5: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

• Current CANopen Solution

CANopen SolutionCANopen Solutionwith fieldbus converterwith fieldbus converter

CANopen SolutionCANopen Solutionin Generallyin Generally

CANopen SolutionCANopen Solutionfor Motionfor Motion

A. CME-COP01 for transforming CANopen to Modbus. For E series only.

E-C

A. E-C series has CANopen Built-in.

B. A2 servo can have CANopen Built-in Type

C. C2000 can have EMC-COP01 which realize CANopen communication directly.

More Expensive

More Advanced

CANopen Introduction

CME-COP01

EMC-COP01

A2

DVP-10MC

A. 10MC can support 16 axes maximum based on CANopen. 8 axes for Interpolation Position linkage Control.

Page 6: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

CANopen Solution based on C2000

• EMC-COP01

• Support CANopen communication directly.

• Two parallel port for by-pass connection.

• Can support velocity mode, profile Torque mode, profile position

and Homing mode.

• Can support C2000 CANopen Master.

Page 7: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

CANopen Solution based on C2000

• CANopen Master (support velocity, profile torque, profile position and Homing mode)

Terminal Resistor Terminal Resistor

Page 8: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

Reference Case

• One successful application for Galvanizing Production Line in Turkey.

Control Network 1

Control Network 2

Page 9: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

Reference Case

Page 10: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

FAQ

1. Why did they use 2 COPM-SL modules there ?

For COPM-SL, the limitation is 390 bytes for TXPDO, 390 bytes for RXPDO. So in this

case, every C2000 will have 8 bytes data in TXPDO, so if only one COPM-SL, it must

cover 8*64=512 bytes which is impossible. So 2 COPM-SL, and 32 notes for each one,

only 32*8=256 bytes for each COPM-SL which is possible.

2. Any suggestion for CANopen Master ?

For Delta Solution now, 28SV + COPM-SL is one old and common master before, but

considering 28SV processing speed, when we add many notes, 28SV is hard to cover all

of them and maybe the delay error there. Hence, in this case, our customer used SA2

which is 5 ~ 6 times faster and cheaper than 28SV since new hardware design. Hence,

please choose Slim 2 series + COPM-SL in the future like SA2, SX2….

Page 11: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

FAQ

3. Any requirement for the CANopen Cable ?

CANopen has a better physical layer requirement. So CANopen has higher anti-disturbance

ability with the required cable. 120ohm characteristic impedance and shielding net absolutely

there. Delta CANopen cables are :

Resistor Resistor

Joint Joint Joint Joint Joint

JointDevice

Device DeviceDevice

Device

Device

Main Line: 1M b/s 40m; 800k b/s 50m; 500k b/s 100m; 250k b/s 250m; 125k b/s 500m; 50K b/s 1000m; 20k b/s 2500m; 10k b/s 5000m

Joint Joint Joint

Y Connection

T Branch

Branch branchBranch Length is 6m maximum

CANopen requires RJ45 crystal head usually, 26AWG cables can be for RJ45, some cables are

thicker than 26AWG which can’t satisfy RJ45 size. Hence TAP-CB01 CB02 can’t satisfy if

sometimes customer want long length with RJ45, and please choose other cables.Wire AWG

CANopen Cables from Delta

Page 12: CanOpen_ Galvanizing Production Line on Metal Industry

Delta Confidential

Appendix

1. Please go to DEN Public Folder to download C2000 application notes,

< C2000 CanOpen Slave in the remote IO>

< C2000 CanOpen Slave in the Speed Mode>

< C2000 CanOpen Slave in the Torque Mode>

< CanOpen Master Speed Function for C2000>

< CanOpen Master Torque Function for C2000>

< C2000 CanOpen Slave in the Position Mode>

< CanOpen Master Position Function for C2000>