canadian mobile products mobile products ... *results based on engine manufacturer and field test...
TRANSCRIPT
Canadian MobileProducts
MOBILE LIGHT, POWER, WATER AND HEAT SOLUTIONS
Durable & reliable mobile equipment • Light Towers
• Diesel Generators
• Gaseous Generators
• Trash Pumps
• Water Trailers
• Combo Units
• Heaters
• Portable Equipment
• Commercial Construction
• Road and Infrastructure
• Oil, Gas and Mining
• Disaster Relief
• Security, Government and Military
• Entertainment and Events
• Airline Ground Support
KEY MARKETS
At Generac Mobile Products, we take pride in delivering mobile equipment that meets the needs of our customers. That’s why we offer a wide range of options on most of our products, including programmable controllers for ease of use, as well as diesel fired block heaters and cold weather packages for reliable performance in extreme cold conditions. For our customers in Canada, we offer configured generators and light towers for use in the unique conditions of the Canadian market. From construction sites to oil fields to music festivals, our customers depend on us to keep them up and running.
• Programmable controls allow for extended runtimes and automated operation, including dusk-to-dawn sensors on our light towers
• Advanced engineering and fuel efficient designs allow for extended runtimes and service intervals so you can stay on the job longer, with less refueling and maintenance
• Safety and operational decals, illuminated controls and nighttime running lights enhance safety on the job
• Telemetry interfacing enables remote monitoring of equipment• Should a problem occur, our knowledgeable technical support team will
keep you up and running, 24/7/365
Generac Mobile Products provides ultimate value, low total cost of ownership and a fast return on your investment.
Built Canada Tough
MLT3060HORIZONTAL MAST
Light Towers
MLT5060VERTICAL MAST
MLT3060VERTICAL MAST
WIDE 4-POINT OUTRIGGERS for maximum stability in extreme weather
conditions; withstands sustained wind speeds up to 65 mph (105 kph)
3000 / 4000 / 5000 SeriesVertical and Horizontal MastAvailable in vertical and horizontal mast Generac Magnum 3000, 4000 and 5000 series light towers are built to withstand the rigors of the Canadian climate. Each series of towers provides an additional level of performance characteristics. 3000 series towers offer a small body chassis, while 5000 series towers offer the widest body and stance in the line, designed for stable towing over rugged terrain and to withstand wind speeds up to 65 mph (105 kph). CAN models include packaged cold weather components for optimum performance in Canada’s extreme-cold temperatures. Our innovative Power Zone Autolight controller is ideal for Canadian locations, offering full programmability including a dusk-to-dawn sensor and automatic start and stop settings for autonomous operation.
LARGE FUEL TANK
for extended run times
TUBULAR STEEL MAST & FRAME
for maximum durability in windy conditions
STEEL ENCLOSURE WITH POWDER
COAT PAINT resists rust, corrosion and UV rays
METAL HALIDE LIGHTS
with tempered glass lenses
provide bright, clean lighting
Light Towers
Power Zone
CONTROLLER with automatic dusk-to-dawn or timer operation
ENGINE TEMPERATURE
MANAGEMENT SYSTEM provides
consistent engine temperatures
regardless of ambient conditions
FOUR 240W GENERAC
LED FIXTURES provide
bright, instant light
ENGINE CONTAINMENT doubles as fluid drain
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
WIDE WHEEL BASE for stability in
towing over rugged terrain
MLT4060MVD The newest member of the 4000 series family, the MLT4060MVD, offers maximum durability and efficiency. Low power consuming LED lights, ECOSpeed engine and large fuel tank allow for an extreme extended runtime of up to 533* on a single tank – for fewer fill-ups and more up-time. An engine temperature management system maintains proper engine conditions for reliable performance in extreme ambient temperatures. Rated to withstand winds up to 65 mph (105 kph).
MLT4060MVD
Power Zone Autolight Controller
LINKTower / PLT240
FULLY ROTATIONAL MAST is safely adjusted from the ground
ECOSpeed ENGINE
for ultimate fuel efficiency
ADJUSTABLE
GALVANIZED MAST
can be raised up to
16 feet (4.9 m)
LOCKABLE
STORAGE
CABINET
for cords and
small tools
LINK TOGETHER two
LINKTowers for precise
and versatile illumination
(1) LINK on a 15A circuit
(2) LINKs on a 20A circuit
ZERO LOCALIZED
EMISSIONS powered
by standard 120V utility
shore power
TRANSPORTABLE Fork
pockets, caster wheel, folding
handles and lift eye
MLT6 SeriesVertical Mast – LED and Metal HalideGenerac Magnum MLT6 series mobile light towers are designed to provide maximum lighting and power with a minimal footprint. MLT6 series towers set up in just one minute, and the rear flip hood provides unobstructed service access. Externally illuminated controls and rear LED trailer / running lights improve visibility and operator safety.
LINKTower Portable LED Light Tower (left page)
LINKTower is a unique portable lighting solution for a wide range of jobs, events and projects - indoors and out. LINKTower provides the same powerful illumination as our full-size LED light towers, but its compact design allows for ultimate versatility and ease of use. Use one, or LINK two towers together. The linking capability allows for flexibility and versatility in lighting events and jobsites. And, because it’s powered by a standard 120V outlet, there are no localized fuel emissions.
CORROSION-PROOF POLY SHELL withstands tough applications and looks better longer
FULLY ROTATIONAL MAST is safely adjusted from the ground
ERGONOMIC 2-handled manual winch standard; electric winch option
LED trailer lights enhance jobsite visibility and safety
COMPACT STORAGE AND TRANSPORT SIZE: 17 towers on a 48’ foot flatbed; 19 on a 53’ flatbed
VERTICAL MAST for quicker, easier deployment and more compact storage
MLT6SM/K
FLIP HOOD for easy access
ECOSpeedENGINE for ultimate fuel efficiency
LARGE FUEL TANK for fewer fill-ups and longer runtimes
Mobile GeneratorsIn addition to EPA final tier 4 compliant engines, Generac Mobile Products offers a selection of diesel generators with Interim Tier 4 and Tier 3 engines. Lower tier engines offer excellent performance without the maintenance required for Final Tier 4 engines. Additionally, these models are often available at a better price. Interim Tier 4 and Tier 3 equipment will be available for a limited time and quantities are limited. Contact your Generac Mobile Products sales representative for current availability.
Like our light towers, our generators are available in special configurations designed for Canadian environments. CAN models include cold weather options for optimum performance in Canada’s extreme cold temperatures.
Canadian VFLEXFlexible Voltage
Unique for our Canadian customers is our VFLEX technology. VFLEX diesel (CAN6) generator models offer an extra 600-volt selection for maximum versatility.
Key Features• No transformer required• All standard voltages plus 600v three phase power• Easy-to-switch voltage selection
Available and easily switchable for use at any time• 120/240V single phase• 208V three phase• 480V three phase• 600V three phase
Key Benefits• Integrated transformer• Lower acquisition cost, faster return on investment• Less weight; easier towing• Fewer components; less parts for maintenance
VFLEX is available in Canada only, indicated by model numbers with the “CAN6”.
Gaseous GeneratorsTraditionally used in oil and gas drilling, our gaseous generators are extremely flexible and easily switch between liquid propane, natural gas or wellhead gas fuel - and can even automatically switch to the designated secondary fuel source if primary fuel is interrupted. With natural gas as an extremely reliable and plentiful source of fuel, new applications are constantly evolving.
Fuel that Makes SenseSwitchable Tri-fuel - LP, NG or Wellhead Gas
Wellhead gas is a byproduct of the oil drilling process. Traditionally flared-off, Generac developed a way to harness wellhead gas to generate power. All Generac Magnum gaseous generators feature a tri-fuel design, easily switching between natural gas (NG), liquid propane (LP) and wellhead gas fuels. Wellhead gas essentially provides a free fuel source for power generation.
Mobile Trash PumpsGenerac Magnum trash pumps are designed for ultimate performance - allowing for fast and efficient high volume dewatering projects. A choice of wet prime and dry prime models allow you to specify the perfect pump for your needs. All models handle water and solids up to 3 inches (76.2 mm) in diameter, and operate for extended run times to ensure that your worksite is clean and ready for the next phase. The LOFA controller with back-lit LCD display makes operation hassle-free.
FINAL TIER 4 engine
LARGE, BACK-LIT
4.3" LCD display
AUTOMATIC start/stop
control for use with
float switch inputs
HIGH EFFICIENCY pump end with
best-in-class suction/discharge height
RUN-DRY SYSTEM for
continuous operations
without need for external
flush water or venting
DURABLE STEEL ROLL-CAGE protects pump
radiator and other components from damage
HIGH PERFORMANCE priming system
options - wet prime, diaphragm or Venturi dry prime
EASY CONVERSION
to optional sound
attenuated flip hood cabinet
(dry prime models only)
VARIETY of hose
connections available
BUILT-IN CONTAINMENT
for all engine fluids
MTP6DZVWITH OPTIONAL ENCLOSURE
MTT15
Water and Combo TrailersOur water and combination utility trailers provide the water, power and light needed to meet the ever-changing needs of worksites and remote project locations. Generac Magnum combo units include powerful metal halide lights, 500 gallons (1895 L) of water and up to 20kW of auxiliary power.
LARGE STEEL FUEL TANK250 gal. (946 L) built into skid
POWERFUL LIGHTINGFour metal halide light fixtures
POWER OPTIONS15kW and 20kW
RUNTIME127 hour maximum
MWT500
TANK 500 gal. (1893 L) water tank (non-potable)
TANK 500 gal. (1893 L) water tank (non-potable)
HOSE STORAGEFour-sided, fender-mounted storage hose bin and secure hose adapter storage
INTEGRATED TRAILER BRAKES with hydraulic or electric surge brakes available
HONDA® PUMP ENGINE
MAC750FFlameless Heater
Mobile Heaters
Flameless Air, Indirect Air and Hydronic Surface
Available in a wide range of BTU outputs, Generac MAC mobile heaters offer a safe and efficient way to heat worksites and surfaces to keep your operations running and workers comfortable and safe in the coldest of temperatures. Flameless heaters provide safe heat for applications in which combustible fumes are present. Indirect heaters offer efficient and reliable heat for a wide range of applications. Hydronic surface heaters warm cold ground and other surfaces to keep projects moving along in the coldest temperatures.
85% BURNER
EFFICIENCY for
reduced fuel costs
DIRECT COUPLED
FANS for simpler use
and less maintenance
needs
EXTENDED DUCT RUNS for greater
reach and placement flexibility
DIESEL FUEL FIRED HEATER
common fuel source for engine/
generator and heater for simplified
fueling and lower operational costs
FULLY
CONTAINED UNIT
for better sound
abatement, reducing
job site noise
INTERNAL
DUCTING STORAGE
to prevent freezing,
damage and theft
NON-TOXIC,
ENVIRONMENTALLY
FRIENDLY heat transfer fluid
110% CONTAINMENT
of system fluids
6-ZONE CAPABILITY
provides for greater
use flexibility; with leak-
proof connections
RETRACTABLE HOSES
Easily deploy and
retract hoses
MAC800GIndirect Heater
DIESEL POWERED
GENERATOR
MAC6000Hydronic Heater
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com20
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com21
Portable Equipment
Generac Mobile Products is proud to offer Generac® and DeWALT® brand portable equipment. These commercial-grade generators, pumps and pressure washers are designed to withstand the rigors of the rental yard and construction site, providing you with the power to take on jobs of all sizes.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com22
Specifications and designs are subject to change.
SpecificationsPLT240 MLT6SMD MLT6SM MLT6SK
Lights PORTABLE MLT6 SERIES
Luminaire Type LED LED Metal Halide Metal Halide
Fixtures 4 - 240W 4 - 240W 4 - 1050W 4 - 1050W
Lumens Per Fixture 22,000 22,000 115,000 115,000
Total Lumens 88,000 88,000 462,000 462,000
Engine
EPA Tier N/A Final Tier 4 Final Tier 4 Final Tier 4
Engine Make N/A Mitsubishi Mitsubishi Kubota
Capacities
Fuel Type Utility Diesel Diesel Diesel
Fuel Capacity Gal (L) N/A 39.9 (151.04) 39.9 (151.04) 39.9 (151.04)
Est. Fuel Consumption @ Full Load: gph (Lph)*
N/A 0.549 (2.078) 0.47 (1.78) 0.50 (1.89)
Est. Fuel Consumption (Lights Only) gph (Lph)*
Unlimited 0.195 (0.738) 0.31 (1.17) 0.33 (1.25)
Approx. Max Runtime Hrs (Lights Only)* Unlimited 205 128 119
Output
Total Rated Power N/A 6kW 6kW 6kW
Weight & Dimensions
Mast Type Vertical Vertical Vertical Vertical
Max Mast Height Ft (M) 16 (4.9) 23 (7.01) 23 (7.01) 23 (7.01)
Mast Stowed (L x W x H) In (M) 54 x 31.5 x 77.5 (1.37 x 0.80 x 1.96) 118 x 57 x 101 (3 x 1.45 x 2.6) 118 x 57 x 101 (3 x 1.45 x 2.6) 118 x 57 x 101 (3 x 1.45 x 2.6)
Dry Weight Lb (Kg) 558 (253) 1332 (604) 1290 ( 585) 1330 (603)
Operating Weight Lb (Kg) 558 (253) 1602 (727) 1560 (708) 1600 (726)
Certifications
CSA Listed Yes Yes Yes Yes
Additional Information
Electric Winch N/A Optional Optional Optional
Cold Climate Package N/A Optional - No Containment Optional - No Containment Optional
Enclosure Material Powder-Coated Steel Impact-Resistent Polymer Impact-Resistent Polymer Impact-Resistent Polymer
Body Type X-Small Small Small Small
Service Interval Hrs N/A 750 750 750
Light Towers
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
Light Tower Cold Climate Package includes:
• 60/40 coolant
• Radiator hose heater
• Heated fuel filter
• 775CCA AGM sealed battery
• Liquid containment
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com23
MLT3060K MLT3060KV MLT3060M MLT3060MV
Lights 3000 SERIES
Luminaire Type Metal Halide Metal Halide Metal Halide Metal Halide
Fixtures 4 - 1050W 4 - 1050W 4 - 1050W 4 - 1050W
Lumens Per Fixture 115,000 115,000 115,000 115,000
Total Lumens 462,000 462,000 462,000 462,000
Engine
EPA Tier Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4
Engine Make Kubota Kubota Mitsubishi Mitsubishi
Capacities
Fuel Type Diesel Diesel Diesel Diesel
Fuel Capacity Gal (L) 33.6 (127.19) 33.6 (127.19) 33.6 (127.19) 33.6 (127.19)
Est. Fuel Consumption @ Full Load: gph (Lph)*
0.50 (1.89) 0.50 (1.89) 0.47 (1.78) 0.47 (1.78)
Est. Fuel Consumption (Lights Only) gph (Lph)*
0.25 (0.95) 0.25 (0.95) 0.24 (0.91) 0.24 (0.91)
Approx. Max Runtime Hrs (Lights Only)* 134 134 140 140
Output
Total Rated Power 6kW 6kW 6kW 6kW
Weight & Dimensions
Mast Type Horizontal Vertical Horizontal Vertical
Max Mast Height Ft (M) 30 (9.14) 25 (7.62) 30 (9.14) 25 (7.62)
Mast Stowed (L x W x H) In (M) 170 x 49 x 68 (4.32 x 1.25 x 1.73) 117 x 58 x 111 (3 x 1.5 x 2.8) 170 x 49 x 68 (4.32 x 1.25 x 1.73) 117 x 58 x 111 (3 x 1.5 x 2.8)
Dry Weight Lb (Kg) 1657 (752) 1707 (774) 1640 (744) 1694 (768)
Operating Weight Lb (Kg) 1873 (850) 1923 (872) 1856 (842) 1910 (866)
Certifications
CSA Listed Yes Yes Yes Yes
Additional Information
Electric Winch N/A Standard N/A Standard
Cold Climate Package Optional Optional Optional Optional
Enclosure Material Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Body Type Narrow Narrow Narrow Narrow
Service Interval Hrs 750 750 750 750
Light Towers
Specifications and designs are subject to change.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
Light Tower Cold Climate Package includes:
• 60/40 coolant
• Radiator hose heater
• Heated fuel filter
• 775CCA AGM sealed battery
• Liquid containment
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com24
SpecificationsMLT4060MVD MLT4060MCAN MLT4060MVCAN MLT4060KCAN MLT4060KVCAN
Lights 4000 SERIES
Luminaire Type LED Metal Halide Metal Halide Metal Halide Metal Halide
Fixtures 4 - 240W 4 - 1050W 4 - 1050W 4 - 1050W 4 - 1050W
Lumens Per Fixture 22,000 115,000 115,000 115,000 115,000
Total Lumens 88,000 462,000 462,000 462,000 462,000
Engine
EPA Tier Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4
Engine Make Mitsubishi Mitsubishi Mitsubishi Kubota Kubota
Capacities
Fuel Type Diesel Diesel Diesel Diesel Diesel
Fuel Capacity Gal (L) 110.1 (416.7) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5)
Est. Fuel Consumption @ Full Load: gph (Lph)*
0.549 (2.078) 0.47 (1.78) 0.47 (1.78) 0.50 (1.89) 0.50 (1.89)
Est. Fuel Consumption (Lights Only) gph (Lph)*
0.195 (0.738) 0.24 (0.91) 0.24 (0.91) 0.25 (0.95) 0.25 (0.95)
Approx. Max Runtime Hrs (Lights Only)* 533 235 235 225 225
Output
Total Rated Power 6kW 6kW 6kW 6kW 6kW
Weight & Dimensions
Mast Type Vertical Horizontal Vertical Horizontal Vertical
Max Mast Height Ft (M) 23 (7.01) 30 (9.14) 25 (7.62) 30 (9.14) 25 (7.62)
Mast Stowed (L x W x H) In (M) 124.5 x 68.2 x 101.2 (3.2 x 1.7 x 2.6)
170 x 68 x 70 (4.32 x 1.73 x 1.78)
115 x 68 x 107 (2.92 x 1.73 x 2.71)
170 x 68 x 70 (4.32 x 1.73 x 1.78)
115 x 68 x 107 (2.92 x 1.73 x 2.71)
Dry Weight Lb (Kg) 1694 (768) 1675 (760) 1759 (798) 1695 (770) 1779 (807)
Operating Weight Lb (Kg) 2770 (1256) 1888 (856) 2162 (981) 1908 (866) 2182 (990)
Certifications
CSA Listed Yes Yes Yes Yes Yes
Additional Information
Electric Winch Optional N/A Standard N/A Standard
Cold Climate Package Optional Standard Standard Standard Standard
Enclosure Material Powder-Coated Aluminum Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Body Type Wide Wide Wide Wide Wide
Service Interval Hrs 750 750 750 750 750
Light Towers
Specifications and designs are subject to change.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
Light Tower Cold Climate Package includes:
• 60/40 coolant
• Radiator hose heater
• Heated fuel filter
• 775CCA AGM sealed battery
• Liquid containment
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com25
MLT4080KCAN MLT4080KVCAN MLT4200ICAN MLT4200IVCAN
Lights 4000 SERIES
Luminaire Type Metal Halide Metal Halide Metal Halide Metal Halide
Fixtures 4 - 1050W 4 - 1050W 4 - 1050W 4 - 1050W
Lumens Per Fixture 115,000 115,000 115,000 115,000
Total Lumens 462,000 462,000 462,000 462,000
Engine
EPA Tier Final Tier 4 Final Tier 4 Interim Tier 4 Interim Tier 4
Engine Make Kubota Kubota Isuzu Isuzu
Capacities
Fuel Type Diesel Diesel Diesel Diesel
Fuel Capacity Gal (L) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5)
Est. Fuel Consumption @ Full Load: gph (Lph)*
0.70 (2.65) 0.70 (2.65) 1.80 (6.81) 1.80 (6.81)
Est. Fuel Consumption (Lights Only) gph (Lph)*
0.35 (1.32) 0.35 (1.32) 0.90 (3.41) 0.90 (3.41)
Approx. Max Runtime Hrs (Lights Only)* 161 161 62 62
Output
Total Rated Power 8kW 8kW 20kW 20kW
Weight & Dimensions
Mast Type Horizontal Vertical Horizontal Vertical
Max Mast Height Ft (M) 30 (9.14) 25 (7.62) 30 (9.14) 25 (7.62)
Mast Stowed (L x W x H) In (M) 170 x 68 x 70 (4.32 x 1.73 x 1.78)
115 x 63 x 111 (2.92 x 1.6 x 2.82)
170 x 68 x 70 (4.32 x 1.73 x 1.78)
115 x 68 x 107 (2.92 x 1.73 x 2.71)
Dry Weight Lb (Kg) 1712 (777) 1785 (810) 2122 (963) 2084 (945)
Operating Weight Lb (Kg) 1925 (874) 2188 (992) 2520 2487 (1128)
Certifications
CSA Listed Yes Yes Yes Yes
Additional Information
Electric Winch N/A Standard N/A Standard
Cold Climate Package Standard Standard Standard Standard
Enclosure Material Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Body Type Wide Wide Wide Wide
Service Interval Hrs 750 750 250 250
Light Towers
Specifications and designs are subject to change.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
Light Tower Cold Climate Package includes:
• 60/40 coolant
• Radiator hose heater
• Heated fuel filter
• 775CCA AGM sealed battery
• Liquid containment
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com26
SpecificationsMLT5060MCAN MLT5060MVCAN MLT5060KCAN MLT5060KVCAN
Lights 5000 SERIES
Luminaire Type Metal Halide Metal Halide Metal Halide Metal Halide
Fixtures 4 - 1050W 4 - 1050W 4 - 1050W 4 - 1050W
Lumens Per Fixture 115,000 115,000 115,000 115,000
Total Lumens 462,000 462,000 462,000 462,000
Engine
EPA Tier Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4
Engine Make Mitsubishi Mitsubishi Kubota Kubota
Capacities
Fuel Type Diesel Diesel Diesel Diesel
Fuel Capacity Gal (L) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5)
Est. Fuel Consumption @ Full Load: gph (Lph)*
0.47 (1.78) 0.47 (1.78) 0.50 (1.89) 0.50 (1.89)
Est. Fuel Consumption (Lights Only) gph (Lph)*
0.24 (0.91) 0.24 (0.91) 0.25 (0.95) 0.25 (0.95)
Approx. Max Runtime Hrs (Lights Only)* 235 235 225 225
Output
Total Rated Power 6kW 6kW 6kW 6kW
Weight & Dimensions
Mast Type Horizontal Vertical Horizontal Vertical
Max Mast Height Ft (M) 30 (9.14) 25 (7.62) 30 (9.14) 25 (7.62)
Mast Stowed (L x W x H) In (M) 170 x 79 x 72 (4.32 x 2 x 1.83)
120 x 79 x 111 (3.05 x 2 x 2.82)
170 x 79 x 72 (4.32 x 2 x 1.83)
120 x 79 x 111 (3.05 x 2 x 2.82)
Dry Weight Lb (Kg) 2104 (954) 2005 (909) 2104 (954) 2018 (915)
Operating Weight Lb (Kg) 2317 (1051) 2408 (1092) 2317 (1051) 2421 (1098)
Certifications
CSA Listed Yes Yes Yes Yes
Additional Information
Electric Winch N/A Standard N/A Standard
Cold Climate Package Standard Standard Standard Standard
Enclosure Material Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Body Type Extra Wide Extra Wide Extra Wide Extra Wide
Service Interval Hrs 750 750 750 750
Light Towers
Specifications and designs are subject to change.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
Light Tower Cold Climate Package includes:
• 60/40 coolant
• Radiator hose heater
• Heated fuel filter
• 775CCA AGM sealed battery
• Liquid containment
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com27
MLT5080KCAN MLT5080KVCAN MLT5200ICAN MLT5200IVCAN
Lights 5000 SERIES
Luminaire Type Metal Halide Metal Halide Metal Halide Metal Halide
Fixtures 4 - 1050W 4 - 1050W 4 - 1050W 4 - 1050W
Lumens Per Fixture 115,000 115,000 115,000 115,000
Total Lumens 462,000 462,000 462,000 462,000
Engine
EPA Tier Final Tier 4 Final Tier 4 Interim Tier 4 Interim Tier 4
Engine Make Kubota Kubota Isuzu Isuzu
Capacities
Fuel Type Diesel Diesel Diesel Diesel
Fuel Capacity Gal (L) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5) 56.4 (213.5)
Est. Fuel Consumption @ Full Load: gph (Lph)*
0.70 (2.65) 0.70 (2.65) 1.80 (6.81) 1.80 (6.81)
Est. Fuel Consumption (Lights Only) gph (Lph)*
0.35 (1.32) 0.35 (1.32) 0.90 (3.41) 0.90 (3.41)
Approx. Max Runtime Hrs (Lights Only)* 161 161 62 62
Output
Total Rated Power 8kW 8kW 20kW 20kW
Weight & Dimensions
Mast Type Horizontal Vertical Horizontal Vertical
Max Mast Height Ft (M) 30 (9.14) 25 (7.62) 30 (9.14) 25 (7.62)
Mast Stowed (L x W x H) In (M) 170 x 79 x 72 (4.32 x 2 x 1.83)
120 x 79 x 111 (3.05 x 2 x 2.82)
170 x 79 x 72 (4.32 x 2 x 1.83)
120 x 79 x 111 (3.05 x 2 x 2.8)
Dry Weight Lb (Kg) 2121 (963) 2035 (923) 2230 (1012) 2313 (1049)
Operating Weight Lb (Kg) 2524 (1145) 2438 (1106) 2633 (1194) 2716 (1232)
Certifications
CSA Listed Yes Yes Yes Yes
Additional Information
Electric Winch N/A Standard Standard N/A
Cold Climate Package Standard Standard Standard Standard
Enclosure Material Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Body Type Extra Wide Extra Wide Extra Wide Extra Wide
Service Interval Hrs 750 750 250 250
Light Towers
Specifications and designs are subject to change.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
Light Tower Cold Climate Package includes:
• 60/40 coolant
• Radiator hose heater
• Heated fuel filter
• 775CCA AGM sealed battery
• Liquid containment
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com28
SpecificationsMLG8K MLG15 MLG20ICAN
Engine MLG SERIES - SINGLE PHASE
EPA Tier Final Tier 4 Final Tier 4 Interim Tier 4
Engine Make Kubota Mitsubishi Isuzu
Hp (kW) Prime @ 1800RPM 13.5 (10.1) 22.3 (16.6) 32.1 (23.9)
Capacities
Fuel Tank Gal (L) 56 (212) 56 (212) 56 (212)
Approx. Max Runtime @ Prime Hrs* 43 43 31
Output
AC Voltage 3-Phase N/A N/A N/A
3 Phase - Prime (kW/kVA) N/A N/A N/A
Amps 3-Phase Prime: 480V (208V) [600V]
N/A N/A N/A
3 Phase - Standby (kW/kVA) N/A N/A N/A
Amps 3-Phase Standby: 480V (208V) [600V]
N/A N/A N/A
AC Voltage 1-Phase N/A N/A N/A
1 Phase - Prime (kW/kVA) 8.1 / 8.1 13 / 13 19 / 19
Amps - 1-Phase Prime: 240V 33 54 79
1 Phase - Standby (kW/kVA) 9 / 9 14 / 14 20 / 20
Amps 1-Phase Standby: 240V 37 58 83
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 105 x 68 x 56 (2.67 x 1.73 x 1.42)
105 x 68 x 56 (2.67 x 1.73 x 1.42)
105 x 68 x 56 (2.67 x 1.73 x 1.42)
Trailered Dry Weight Lb (Kg) 1030 (467) 1425 (646) 1455 (660)
Trailered Operating Weight Lb (Kg) 1250 (567) 1823 (827) 1853 (841)
Certifications
CSA Listed Yes Yes Yes
Transport Canada Tank N/A N/A N/A
Additional Information
Cold Climate Package Optional Optional Standard
VFLEX 600V No No No
Cabinet Type Standard Standard Standard
Diesel Generators
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com29
MMG25FHICAN MMG45FHKCAN MMG55FHDCAN**
Engine 1/3 PHASE SWITCHABLE
EPA Tier Interim Tier 4 Interim Tier 4 Tier 3
Engine Make Isuzu Kubota Deere
Hp (kW) Prime @ 1800RPM 32.1 (23.9) 53 74
Capacities
Fuel Tank Gal (L) 106 (401) 106 (401) 106 (401)
Approx. Max Runtime @ Prime Hrs* 45.4 31 28.5
Output
AC Voltage 3-Phase
3 Phase - Prime (kW/kVA) 18 / 23 33 / 41 44 / 55
Amps 3-Phase Prime: 480V (208V) [600V]
28 (64) 49 (114) 71 (164)
3 Phase - Standby (kW/kVA) 20 / 25 35 / 44 48 / 60
Amps 3-Phase Standby: 480V (208V) [600V]
30 (69) 53 (122) 78 (180)
AC Voltage 1-Phase
1 Phase - Prime (kW/kVA) 15 / 15 30 / 30 42 / 42
Amps - 1-Phase Prime: 240V 63 125 188
1 Phase - Standby (kW/kVA) 16 / 16 33 / 33 46 / 46
Amps 1-Phase Standby: 240V 67 138 204
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 150 x 57 x 67 (3.81 x 1.45 x 1.70)
150 x 57 x 67 (3.81 x 1.45 x 1.70)
150 x 57 x 67 (3.81 x 1.45 x 1.70)
Trailered Dry Weight Lb (Kg) 2289 (1038) 2853 (1294) 3050 (1384)
Trailered Operating Weight Lb (Kg) 2758 (1251) 3606 (1636) 3770 (1710)
Certifications
CSA Listed Yes Yes Yes
Transport Canada Tank N/A N/A N/A
Additional Information
Cold Climate Package Standard Standard Standard
VFLEX 600V No No No
Cabinet Type Flip Hood Flip Hood Flip Hood
Diesel Generators
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change. **Limited quantities.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com30
SpecificationsMMG25FHICAN6 MMG45FHKCAN6 MMG55FHDCAN6** MMG75CAN**
Engine VFLEX 1/3 PHASE SWITCHABLE
EPA Tier Interim Tier 4 Interim Tier 4 Tier 3 Tier 3
Engine Make Isuzu Kubota Deere Deere
Hp (kW) Prime @ 1800RPM 32.1 (23.9) 53 (39) 74 (55) 91
Capacities
Fuel Tank Gal (L) 106 (401) 106 (401) 106 (401) 147 (556.5)
Approx. Max Runtime @ Prime Hrs* 45.4 31 28.5 24
Output
AC Voltage 3-Phase
3 Phase - Prime (kW/kVA) 19 / 24 34 / 42 45 / 56 58 / 72
Amps 3-Phase Prime: 480V (208V) [600V]
29 (56) [23] 48 (84) [40] 62 (121) [54] 87 (200)
3 Phase - Standby (kW/kVA) 21 / 26 37 / 46 50 / 63 63 / 79
Amps 3-Phase Standby: 480V (208V) [600V]
30 (59) [25] 55 (111) [44] 65 (128) [60] 95 (219)
AC Voltage 1-Phase
1 Phase - Prime (kW/kVA) 9 / 9 15 / 15 19 / 19 52 / 52
Amps - 1-Phase Prime: 240V 38 63 79 217
1 Phase - Standby (kW/kVA) 10 / 10 17 / 17 20 / 20 56 / 56
Amps 1-Phase Standby: 240V 40 71 83 233
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 150 x 57 x 67 (3.81 x 1.45 x 1.70)
150 x 57 x 67 (3.81 x 1.45 x 1.70)
152 x 58 x 83 (3.81 x 1.45 x 2.11)
158 x 60 x 84 (4.01 x 1.52 x 2.13)
Trailered Dry Weight Lb (Kg) 2289 (1038) 2853 (1294) 3050 (1384) 3913 (1775)
Trailered Operating Weight Lb (Kg) 2758 (1251) 3606 (1636) 3770 (1710) 4957 (2248)
Certifications
CSA Listed Yes Yes Yes Yes
Transport Canada Tank N/A N/A N/A Yes
Additional Information
Cold Climate Package Standard Standard Standard Standard
VFLEX 600V Yes Yes Yes No
Cabinet Type Flip Hood Flip Hood Flip Hood Standard
Diesel Generators
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change. **Limited quantities.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com31
MMG100CAN** MMG120CAN** MMG150CAN** MMG185CAN** MMG235CAN**
Engine
EPA Tier Tier 3 Tier 3 Tier 3 Tier 3 Tier 3
Engine Make Deere Deere Deere Deere Deere
Hp (kW) Prime @ 1800RPM 122 144 179 258 286
Capacities
Fuel Tank Gal (L) 147 (556.5) 342 (1295) 342 (1295) 342 (1295) 342 (1295)
Approx. Max Runtime @ Prime Hrs* 22 44 36 25 21
Output
AC Voltage 3-Phase
3 Phase - Prime (kW/kVA) 78 / 98 93 / 116 116 / 145 162 / 202 187 / 234
Amps 3-Phase Prime: 480V (208V) [600V]
118 (272) 140 (322) 174 (402) 243 (561) 307 (708)
3 Phase - Standby (kW/kVA) 86 / 107 102 / 127 127 / 159 177 / 221 204 / 255
Amps 3-Phase Standby: 480V (208V) [600V]
129 (297) 153 (353) 191 (441) 266 (613) 280 (647)
AC Voltage 1-Phase
1 Phase - Prime (kW/kVA) 71 / 71 85 / 85 106 /106 137 / 137 N/A
Amps - 1-Phase Prime: 240V 296 354 442 571 N/A
1 Phase - Standby (kW/kVA) 75 / 75 91 / 91 114 / 114 151 / 151 N/A
Amps 1-Phase Standby: 240V 313 379 475 629 N/A
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 158 x 60 x 84 (4.01 x 1.52 x 2.13)
210 x 86 x 93 (5.33 x 2.18 x 2.36)
210 x 86 x 93 (5.33 x 2.18 x 2.36)
210 x 86 x 93 (5.33 x 2.18 x 2.36)
210 x 86 x 93 (5.33 x 2.18 x 2.36)
Trailered Dry Weight Lb (Kg) 4104 (1860) 6825 (3096) 7340 (3329) 8450 (3833) 8450 (3833)
Trailered Operating Weight Lb (Kg) 5062 (2296) 9310 (4223) 9896 (4489) 11040 (5008) 11040 (5008)
Certifications
CSA Listed Yes Yes Yes Yes Yes
Transport Canada Tank Yes Yes Yes Yes Yes
Additional Information
Cold Climate Package Standard Standard Standard Standard Standard
VFLEX 600V No No No No No
Cabinet Type Standard Standard Standard Standard Standard
Diesel Generators
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change. **Limited quantities.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com32
SpecificationsMMG75CAN6** MMG100CAN6** MMG120CAN6** MMG150CAN6** MMG185CAN6**
Engine VFLEX
EPA Tier Tier 3 Tier 3 Tier 3 Tier 3 Tier 3
Engine Make Deere Deere Deere Deere Deere
Hp (kW) Prime @ 1800RPM 91 (68) 122 (91) 144 (107) 179 (134) 258 (193)
Capacities
Fuel Tank Gal (L) 147 (556) 147 (556) 342 (1295) 342 (1295) 342 (1295)
Approx. Max Runtime @ Prime Hrs* 24 22 44 36 25
Output
AC Voltage 3-Phase
3 Phase - Prime (kW/kVA) 58 / 72 78 / 97 94 / 117 119 / 149 172 / 215
Amps 3-Phase Prime: 480V (208V) [600V]
87 (180 [69] 108 (215) [93] 135 (271) [113] 173 (347) [143] 256 (577) [207]
3 Phase - Standby (kW/kVA) 63 / 79 85 / 106 102 / 128 130 / 163 188 / 235
Amps 3-Phase Standby: 480V (208V) [600V]
93 (184) [76] 116 (229) [102] 143 (285) [123] 188 (375) [157] 279 (630) [226]
AC Voltage 1-Phase
1 Phase - Prime (kW/kVA) 29 / 29 35 / 35 40 / 40 50 / 50 90 / 90
Amps - 1-Phase Prime: 240V 121 146 167 208 375
1 Phase - Standby (kW/kVA) 31 / 31 37 / 37 44 / 44 54 / 54 94 / 94
Amps 1-Phase Standby: 240V 129 154 183 225 392
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 158 x 60 x 84 (4.01 x 1.52 x 2.13)
158 x 60 x 84 (4.01 x 1.52 x 2.13)
210 x 86 x 93 (5.33 x 2.18 x 2.29)
210 x 86 x 93 (5.33 x 2.18 x 2.29)
210 x 86 x 93 (5.33 x 2.18 x 2.36)
Trailered Dry Weight Lb (Kg) 3913 (1775) 4104 (1860) 6825 (3096) 7340 (3329) 8450 (3833)
Trailered Operating Weight Lb (Kg) 4957 (2248) 5062 (2296) 9310 (4223) 8500 (3855) 11040 (5008)
Certifications
CSA Listed Yes Yes Yes Yes Yes
Transport Canada Tank Yes Yes Yes Yes Yes
Additional Information
Cold Climate Package Standard Standard Standard Standard Standard
VFLEX 600V Yes Yes Yes Yes Yes
Cabinet Type Standard Standard Standard Standard Standard
Diesel Generators
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change. **Limited quantities.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com33
MMG235CAN6** MMG320CAN** MMG320CAN6** MMG625VT2**
Engine VFLEX 1/3 PHASE SWITCHABLE VFLEX 1/3 Phase Switchable
EPA Tier Tier 3 Tier 3 Tier 3 Tier 2 Flex
Engine Make Deere Deere Deere Volvo
Hp (kW) Prime @ 1800RPM 286 (213) 384 384 724
Capacities
Fuel Tank Gal (L) 342 (1295) 459 (1737.5) 459 (1737.5) 653 (2472)
Approx. Max Runtime @ Prime Hrs* 21 24 24 18
Output
AC Voltage 3-Phase
3 Phase - Prime (kW/kVA) 190 / 237 254 / 218 258 / 322 503 / 629
Amps 3-Phase Prime: 480V (208V) [600V]
281 (611) [228] 419 (966) 382 (767) [310] 480
3 Phase - Standby (kW/kVA) 208 / 260 275 / 344 281 / 351 550 / 688
Amps 3-Phase Standby: 480V (208V) [600V]
307 (638) [250] 385 (888) 413 (826) [338] 828 (1910)
AC Voltage 1-Phase
1 Phase - Prime (kW/kVA) N/A N/A N/A N/A
Amps - 1-Phase Prime: 240V N/A N/A N/A N/A
1 Phase - Standby (kW/kVA) N/A N/A N/A N/A
Amps 1-Phase Standby: 240V N/A N/A N/A N/A
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 210 x 86 x 93 (5.33 x 2.18 x 2.36)
230 x 102 x 110 (5.84 x 2.59 x 2.79)
230 x 102 x 110 (5.84 x 2.59 x 2.79)
264 x 102 x 129 (6.71 x 2.59 x 3.28)
Trailered Dry Weight Lb (Kg) 8450 (3833) 10912 (4950) 10912 (4950) 17,240 (7,820)
Trailered Operating Weight Lb (Kg) 11040 (5008) 14372 (6519) 14372 (6519) 22,000 (9,979)
Certifications
CSA Listed Yes Yes Yes Yes
Transport Canada Tank Yes Yes Yes N/A
Additional Information
Cold Climate Package Standard Standard Standard Optional
VFLEX 600V Yes No Yes No
Cabinet Type Standard Standard Standard Standard
Diesel Generators
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change. **Limited quantities.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com34
Specifications and designs are subject to change. **Limited quantities.
SpecificationsMTP4DZD MTP4DZV MTP6DZD MTP6DZV MTP6000D3**
Engine DRY PRIME
EPA Tier Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4 Tier 3
Engine Make Deutz Deutz Deutz Deutz Deere
Hp (Prime @ 2600RPM) 49 49 74.2 74.2 75
Fuel Type Diesel Diesel Diesel Diesel Diesel
Fuel Tank Gal (L) 113 (428) 113 (428) 113 (428) 113 (428) 110 (416)
Pump & Performance
Pump Make Cornell Cornell Cornell Cornell Pioneer
Size In (mm) 4 (101.6) 4 (101.6) 6 (152.4) 6 (152.4) 6 (152.4)
Priming Type Diaphragm Venturi Diaphragm Venturi Diaphragm
Gpm (Lpm) 1450 (5489) 1450 (5489) 2750 (10409) 2750 (10409) 3050 (11546)
Total Dynamic Head Ft (M) 165 (50.29) 165 (50.29) 150 (45.7) 150 (45.7) 145 (44)
Max Lift Suction Ft (M) 28 (8.5) 28 (8.5) 28 (8.5) 28 (8.5) 28 (8.5)
Max Solids In (mm) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3.0 (76.2)
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 150.12 x 75 x 73.88 (3.813 x 1.905 x 1.977)
150.12 x 75 x 73.88 (3.813 x 1.905 x 1.977)
150.12 x 75 x 73.88 (3.813 x 1.905 x 1.977)
150.12 x 75 x 73.88 (3.813 x 1.905 x 1.977)
138 x 57 x 78 (3.51 x 1.45 x 1.98)
Trailered Dry Weight Lb (Kg) 3586 (1627) / Enclosed 3836 (1740)
3554 (1612) / Enclosed 3804 (1725)
3873 (1756) / Enclosed 4123 (1870)
3841 (1742) / Enclosed 4090 (1855) 3060 (1388)
Trailered Operating Weight Lb (Kg) 4400 (1996) / Enclosed 4650 (2109)
4368 (1981) / Enclosed 4618 (2094)
4687 (2126) / Enclosed 4937 (2239)
4655 (2111) / Enclosed 4904 (2224) 3852 (1747)
Certifications
CSA Listed Yes Yes Yes Yes Yes
Additional Information
Sound Attenuated Enclosure Optional Optional Optional Optional Not Available
MTP4SZ MTP6SZ MTP6000S3**
Engine WET PRIME
EPA Tier Final Tier 4 Final Tier 4 Tier 3
Engine Make Deutz Deutz Deere
Hp (Prime @ 2600RPM) 49 74.2 82
Fuel Type Diesel Diesel Diesel
Fuel Tank Gal (L) 113 (428) 113 (428) 110 (416)
Pump & Performance
Pump Make Cornell Cornell Pioneer
Size In (mm) 4 (101.6) 6 (152.4) 6 (152.4)
Priming Type Wet Wet Wet
Gpm (Lpm) 900 (3407) 1680 (6359) 3050 (11546)
Total Dynamic Head Ft (M) 150 (45.7) 170 (52) 165 (50.3)
Max Lift Suction Ft (M) 28 (8.5) 28 (8.5) 28 (8.5)
Max Solids In (mm) 3 (76.2) 3 (76.2) 3 (76.2)
Weight & Dimenions
Trailer Mounted ( L X W X H ) In (M) 150.12 x 75 x 73.88 (3.813 x 1.906 x 1.877)
150.12 x 75 x 73.88 (3.813 x 1.906 x 1.877)
138 x 57 x 78 (3.51 x 1.45 x 1.98)
Trailered Dry Weight Lb (Kg) 3714 (1685) 3914 (1775) 3334 (1512)
Trailered Operating Weight Lb (Kg) 4528 (2054) 4728 (2144) 4126 (1871)
Certifications
CSA Listed Yes Yes Yes
Additional Information
Sound Attenuated Enclosure Not Available Not Available Not Available
Pumps
Pumps
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com35
MTT15 MTT20
Engine
EPA Tier Interim Tier 4 Interim Tier 4
Engine Make Mitsubishi Isuzu
Hp (Prime @ 1800RPM) (kW) 23.5 (17.5) 36.2
Capacities
Fuel Type Diesel Diesel
Fuel Tank Gal (L) 246 (931) 246 (931)
Approx. Max Runtime Hrs (@ Prime)* 176 109
Water Tank (Gal (L) 500 (1895) 500 (1895)
Output
1 Phase - Prime (kW/kVA) 13 / 13 19 / 19
Amps - 1-Phase Prime: 240V 54 79
1 Phase - Standby (kW/kVA) 14.0 (14.0) 20 (20)
Amps 1-Phase Standby: 240V 58 83
Lights
Luminaire Type Metal Halide Metal Halide
Fixtures 4 - 1050W 4 - 1050W
Lumens Per Fixture 115,000 115,000
Total Lumens 462,000 462,000
Weight & Dimensions
Mast Type Vertical Vertical
Max Mast Height Ft (M) 31.5 (9.6) 31.5 (9.6)
Mast Stowed ( L X W X H ) In (M) 210 x 86 x 83 (5.3 x 2.18 x 2.1) 210 x 86 x 83 (5.3 x 2.18 x 2.1)
Dry Weight Lb (Kg) 4702 (2133) 5181 (2350)
Operating Weight Lb (Kg) 10442 (4736) 10921 (4954)
Certifications
CSA Listed Yes Yes
Additional Information
Enclosure Material Powder-Coated Steel Powder-Coated Steel
Cold Climate Package Optional Optional
Combo Units MWT500
Engine
EPA Tier Final Tier 4
Engine Make Honda
Hp (Kw) Prime @ 3600RPM 3.5 (2.6)
Fuel Type Diesel
Fuel Tank Gal (L) 0.66 (2.5)
Approx. Fuel Consumption @ Prime Gph (Lph)
0.18 (0.68)
Capacities
Water Tank Gal (L) 500 (1895)
Fill Rate @ Full Throttle With Full Tank 3 - 4 min
Pump Make Tsurumi
Pump Type Centrifugal
Gpm (Lpm) 137 (517)
Weight & Dimenions
Trailer Mounted ( L X W X H ) In (M) 160 x 77 x 64 (4.06 x 1.96 x 1.63)
Trailered Dry Weight Lb (Kg) 1747 (792)
Trailered Operating Weight Lb (Kg) 5747 (2607)
Certifications
CSA Listed Yes
Water Trailer
Generator Cold Climate Package includes:
• 60/40 coolant
• Heated fuel filter
• Block heater
• Liquid containment
• Clutch fan
• Transport Canada tank
Specifications and designs are subject to change. **Limited quantities.
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age and maintenance of equipment, environmental conditions and fuel density. Consult the Owner’s Manual for fuel and maintenance recommendations.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com36
Specifications and designs are subject to change.
SpecificationsMAC6000
Engine HYDRONIC
EPA Tier Final Tier 4 Weight & Dimensions
Engine Make IsuzuTrailer Mounted ( L X W X H ) In (M) 180 x 95 x 103
(4.57 x 2.41 x 2.62)Capacities
Fuel Type Diesel Trailered Dry Weight Lb (Kg) 7640 (3465)
Fuel Tank Gal (L) 225 (852) Trailered Operating Weight Lb (Kg) 10440 (4736)
Approx. Max Runtime Hrs (@ Prime)
49.6 Certifications
Heater Fluid Gal (L) 135 (511) CSA Listed Yes
Heater Additional Information
Burner Make Riello Enclosure Material Powder-Coated Steel
Heat Output BTUs 630,000 Cold Climate Package Optional
Max Output Temperature 185°F (85°C)
Fluid Temperature Range 65-185°F (18-85°C)
Number of Zones (Hoses) 6
Hose Size In (mm) 0.75 (19.05)
Individual Hose Length Ft (M) 500 (152.4)
Total Hose Length Ft (M) 3000 (914.4)
Estimated Heater Efficiency 85%
MAC400FHC MAC550F MAC750F MAC950F
Engine FLAMELESS
EPA Tier Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4
Engine Make Isuzu Isuzu Isuzu Deere
Capacities
Fuel Type Diesel Diesel Diesel Diesel
Fuel Tank Gal (L) 55 (208.2) 111 (420.18) 160 (605.67) 160 (605.67)
Approx. Max Runtime Hrs (@ Prime)
18.8 37.6 47.8 35.8
Heat Transfer Fluid Gal (L) 24 (90.85) 24 (90.85) 25 (94.64) 28 (105.99)
Heater
Heat Output BTUs*** 432,000 432,000 472,500 958,000
Max Output Temperature 180°F (82°C) 180°F (82°C) 180°F (82°C) 180°F (82°C)
Duct Diameter In (mm) 1 x 12 (304.8) 2 x 12 (304.8) 2 x 12 (304.8 1 x 20 (508)
Duct Length Ft (M) 25 (7.62) 25 (7.62) 25 (7.62) 25 (7.62)
Estimated Heater Efficiency 85% 85% 85% 85%
Air Flow CFM 1400 - 3600 1400-3500 2650 - 5500 3000-6000
Pressure In/H2O 9 5 5 6
Weight & Dimensions
Trailer Mounted ( L X W X H ) In (M) 120 x 54 x 82 (3.05 x 1.37 x2.08)
171 x 72 x 81 (4.34 x 1.83 x 2.06)
191 x 72 x 88 (4.85 x 1.83 x 2.24)
191 x 72 x 88 (4.85 x 1.83 x 2.24)
Trailered Dry Weight Lb (Kg) 4360 (1978) 4480 (2032) 5540 (2513) 6330 (2871)
Trailered Operating Weight Lb (Kg) 4700 (2132) 5180 (2350) 6400 (2903) 7900 (3583)
Certifications
CSA Listed Yes Yes Yes Yes
Additional Information
Enclosure Material Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Containment 110% 110% 110% 110%
Heaters
Heaters
***Calculated using maximum fuel consumption at full rated horsepower as provided by the engine manufacturer.
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com37
Specifications and designs are subject to change.
Heaters MIH400HC MAC400G MAC800G MAC1.2G MAC2.5ES MIH4.2ES
Engine INDIRECT
EPA Tier Final Tier 4 Final Tier 4 Final Tier 4 Final Tier 4 N/A N/A
Engine Make Isuzu Isuzu Isuzu Isuzu Shore Power Shore Power
Capacities
Fuel Type Diesel Diesel Diesel Diesel Utility Utility
Fuel Tank Gal (L) 52 (196.84) 118 (446.5) 189 (715.44) 270 (1022) N/A N/A
Approx. Max Runtime Hrs (@ Prime) 18 41 32.8 33.8 N/A N/A
Heater
Burner Make Riello Riello Riello Riello Riello Riello
Burner Type Single Stage Single Stage Two Stage Two Stage Two Stage Two Stage
Heat Output BTUs 400,000 400,000 800,000 1,200,000 2,500,000 4,200,000
Max Output Temperature 180 F (82 C) 180 F (82 C) 180 F (82 C) 180 F (82 C) 180 F (82 C) 180 F (82 C)
Duct Diameter In (mm) 1 x 12 (304.8) 1 x 12 (304.8) 2 x 12 (304.8) 1 x 12 (304.8) 1 x 30 (762) 1 x 36 (914.4)
Duct Length Ft (M) 25 (7.62) N/A N/A N/A N/A N/A
Estimated Heater Efficiency 85% 85% 85% 85% 85% 85%
Air Flow CFM 3600 1700 3900 6500 12000 21000
Pressure In/H2O 9 3 3 3 3 3
Weight & Dimenions
Trailer Mounted ( L X W X H ) In (M) 168 x 50 x 72 (4.28 x 1.27 x 1.83)
178 x 72 x 76.3 (4.52 x 1.83 x 1.94)
186 x 72 x 87.5 (4.72 x 1.83 x 2.22)
255 x 96 x 102 (6.47 x 2.44 x 2.59)
Trailered Dry Weight Lb (Kg) 4000 (1814) 3700 (1678) 4900 (2223) 8265 (3749)
Trailered Operating Weight Lb (Kg) 4500 (2041) 4415 (2003) 6080 (2758) 10280 (4663)
Skid Mounted ( L X W X H ) In (M) 240 x 102 x 105 (6.1 x 2.59 x 2.67)
289 x 102 x 118 (7.34 x 2.59 x 3.0)
Skidded Dry Weight Lb (Kg) 10470 (4749) 13200 (5987)
Skidded Operating Weight Lb (Kg) 11028 (5002) 14260 (6468)
Certifications
CSA Listed Yes Yes Yes Yes Yes Yes
Additional Information
Enclosure Material Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel
Containment Not Available Not Available Not Available Not Available N/A N/A
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com38
Notes
800-926-9768 | 920-361-4442 www.generacmobi leproducts .com39
For more information,visit us online at
www.generacmobileproducts.com
Part No. 0204330 REV 08/2017©2017 Generac Power Systems, Inc. All Rights Reserved.Specifications are subject to change without notice.
Generac Mobile Products215 Power Drive, Berlin, WI 54923
GeneracMobileProducts.com | 800-926-9768 | 920-361-4442