campus signage manual
TRANSCRIPT
C A M P U S S I G N A G E M A N U A LPrepared by the Facilities Management Unit
1
Contents
Introduction pg 3
Section 1
Purpose pg 4
Using the campus signage manual pg 5
Signage Design pg 6
Signage rules pg 7
Campus Signage Statement pg 8
Glossary of terms pg 9
Procedures pg 10
Section 2
Signage Request Procedure pg 11
Requesting Commercial Signage Procedure pg 15
Permanent Standard Campus Signage Technical Specification pg 22
Section 3
Campus Map Signs pg 23
Campus Street Signs pg 26
Directory Board Signs pg 29
Building identification Signs pg 36
Corporate Identification Signs pg 40
Functional Area identification Signs pg 45
Blade Amenity Signs pg 48
Door Signs pg 98
Fire and Safety Signs pg 112
Car Park Entry Signs pg 114
Other Signs of Interest pg 116
Section 4
2
I N T R O D U C T I O N
33
Introduction
BackgroundThe Facilities Management Unit is responsible for ensuring that corporate standards are maintained in the development and implementation of all signage across the University. The Campus Signage Manual was developed in 2001 using a collaborative approach with key stakeholders across the University. Since then, there has been considerable effort in ensuring consistency in corporate standards is maintained for directional signage whilst ensuring opportunities to promote the University and its stakeholders are achieved. The manual provides clearly defined signage instructions for the design, development and installation of standardised signage on all campuses of the University. This manual will continue to be used as a basis in the development and implementation of improved signage across the University. PurposeThe purpose of the Campus Signage Manual is to provide tools and processes for the development and implementation of all University signage. This has ensured that the delivery of services to our stakeholders is enhanced through the appropriate use of directional and way-finding signage across all campuses. The University has also seen a progressive roll-out of corporate signage across all campuses since the implementation of these standards. Reference to relevant Australian and International Standards, Occupational Health, Safety and Welfare Regulations, and relevant Government and University Acts, guidelines and regulations are used to ensure compliance levels are maintained. Developing signage specificationsThe following way-finding principles are used in the development of new signage specifications: Signage designs shall be developed to complement existing signage and be
sympathetic with and contribute to the promotion of the University’s corporate image and market positioning.
Australian and International Standards shall guide the technical and physical aspects of all signage including compliance to regulatory signage.
Signage design shall overcome language and communication barriers where appropriate and instil the principals of way-finding.
Identification and location of buildings, facilities and services shall be quick and easy for internal and external customers of the University.
44
About The ManualThe manual is presented in 5 sections Section 1Introduction Campus Signage Statement Glossary of Terms Section 2Standard Operating Procedures and Forms Section 3Signage Design Specifications Section 4Other Signs of Interest Using the Campus Signage ManualStakeholders (including external contractors and consultants) are able to use the information contained in the Campus Signage Manual to assist in determining their specific signage requirements:
Section 2 includes standard operating procedures and request forms that provide information on how to order your signage requirements.
Section 3 includes technical specifications for all corporate signage designs currently available. The technical specifications are sorted by relevant signage type to assist in identification of signage designs.
Section 4 provides a visual display of additional signage that has been
developed using elements of existing corporate standards and modified to suit the needs of stakeholders and or building design.
In all cases, modification has occurred with due consideration given to approved use of University logo and co-branding logo’s and is subject to change depending on the needs of individual stakeholder groups.
Distribution of the ManualThe Campus Signage Manual is available online at the following address: http://www.unisa.edu.au/facilities/contractors/signage.asp Copies of the manual are also available on request by contacting the Facilities Management Unit.
55
Quality ManagementThe Campus Signage Manual is a quality document and as such shall be evaluated and updated at regular intervals. This includes formal auditing processes for all new and existing signage on campus to ensure:
Integrity of UniSA logo and style guide is maintained Compliance to legislative and corporate signage standards Maintenance of existing signage; and Implementation of new signage as required.
Signage DesignA coordinated and consistent approach in the format, construction, and use of text, graphics, materials, and colour has been used in the design of corporate signage documented in the Campus Signage Manual. To facilitate global understanding, the design of campus signage draws on three different forms of communication; written word, graphics and colour. Consultation regarding signage also occurred with staff, students and the RSB throughout the design phase in 2001 and again with signage consultants, internal stakeholders and the Royal Society for the Blind as part of the review phase in 2008/2009. There is an emphasis on ease of identification, which has been promoted through the placement of signage, use of colour and easily identified graphics. The use of colour also enables the grouping of particular amenities for easy identification. Classification, Types and Styles of Signage The Campus Signage Manual documents classification, types and styles of corporate signage. Signage across the University is sorted in the following manner: Classification of Signage Types of Signage Styles of Signage
Images are also provided of other signs of interest including major signage for new building programs that may be suitable for further use or adaption depending on the needs of the stakeholder group. Types of SignageEleven main types of signage are identified in the Campus Signage Manual: Campus Signature Campus Maps Directory Boards Building Identification Functional Area Identification Corporate Identification Blade Amenity Identification Door / Pigeon Hole Plates Evacuation Parking
66
Manufacturing and InstallationTo assist with standardisation, cost effectiveness and quality of work, the manufacture and installation of signage is undertaken by the Facilities Management Unit with the use of appropriate external contractors and suppliers nominated on the relevant Contractors Register(s). Signage RulesA number of rules apply to the design and implementation of corporate signage to ensure consistency in placement, content and format of information: Examples of such rules include:
Standard font and size applied to all text using frutiger. Standard text used on door plates may include professional titles ie Dr,
Prof, and Associate Professor but do not include personal titles such as Ms, Mr, Miss.
Two metre clear space to be applied in surrounding area for directory boards
Staff names shall not be included on building and floor directory boards and information shall be alphabetised for consistency and ease of use
Use of University and co-branding logo’s shall comply with University style guide
Implementation of legislative signage standards in areas such Evacuation Plans, Fire & Safety and Hazardous Signage shall be consistent in size and placement:
o External - 250mm metal plate with vinyl attached or vinyl on glass if appropriate
o Internal - 150 mm using vinyl Approvals and Timelines Requests for new signage designs that do not form part of existing corporate signage standards must be approved by Facilities Management Unit to ensure design and intended use meet corporate guidelines relating to University logo, content and placement of signage design. Installation of all signage occurs on a rotational basis across all campuses and it is intended that any door signage is installed within 10 working days from placement of your initial signage request. Approvals and timelines for all other standard corporate signage will be negotiated with the customer, with consideration given to the urgency and type of signage required.
77
Campus Signage Statement The University of South Australia is committed to providing suitable directional signage that meets the needs of our staff, students and general public. This statement reflects the processes documented in the Campus Signage Manual which have been established to ensure a standardised approach to the development and implementations of all signage across the University. The design and implementation of all signage shall reflect the standard technical specifications for individual signs documented in the Campus Signage Manual in terms of visual display, quality of work, and use of materials. Signage requirements that are extraordinary in nature and are not specified in the Campus Signage Manual shall be reviewed by the Business & Administration Coordinator, Facilities Management Unit for development and approval to ensure consistency in signage design and placement. All signage shall conform to the Campus Signage Manual and the University Branding and Style Guide which shall be developed in conjunction with rules, regulations and guidelines stipulated in appropriate legislation and standards. Standard operating procedures also provide step-by-step instructions relating to requests for corporate signage requirements. These procedures provide clearly defined actions and responsibilities for the development, implementation and review of signage across the University. The campus Signage Manual is a quality document and shall be subject to regular reviews as part of this University’s commitment to continuous improvement.
88
Glossary of Terms
PurposeThe purpose of this section is to provide a list of descriptions and/or definitions of some of the terms used throughout the Campus Signage Manual. Commercial signage:Signage which is not documented in the Campus Signage Manual and which is associated with an external commercial provider or tenant located on University campuses. Directional signage:All types of signage that provides way-finding information to a specific location, building or service. External signage:Signage that is placed in an external environment on a University campus or building. Internal signage:Signage that is placed internally within buildings on a University campus. Major project signage:Signage that forms part of a major refurbishment or building program that may, or may not be documented in the Campus Signage Manual. New campus signage:Any signage proposal that is not documented in the Campus Signage Manual. Permanent standard campus signage:All signage documented in the campus Signage Manual. Temporary campus signage:Temporary campus signage are those signs which have been developed by internal and external customers on an ad-hoc basis for temporary purposes and are not defined as corporate standard signage.
99
P R O C E D U R E S
1010
STANDARD OPERATING PROCEDURE: Signage Request Procedure
1. Introduction This procedure has been developed to provide University stakeholders with appropriate information for ordering UniSA corporate standard signage including door signage and other signage designs.
2. Purpose
The purpose of this procedure is to outline the process for ordering, approvals and installation of corporate standard signage across all UniSA campuses.
3. Definitions
Corporate signage standards – refers to all signage designs approved for installation on University campuses.
4. Procedure
4.1 Requesting a Door Plate
Requests for all door signage shall use the Standard Door Plate Job Sheet (Form No: FMU-064). This form provides information on the type of signage required i.e. door plate style, vinyl text as well as the door type i.e. solid door, glass door.
4.2 Requesting Corporate Standard Signage
Requests for all other types of corporate standard signage shall use the Signage Request Form (Form No: FMU-065) where a detailed description of the signage requirements can be provided.
4.3 Approval of signage
It is the responsibility of the customer to provide a relevant cost centre and sign for approval prior to commencement of work.
4.4 Errors and Omissions
Any costs associated with errors and/or omissions to signage requests by the customer shall be charged to the respective cost centre.
11
4.5 Signage Design and installation
Disability Access and Occupational Health, Safety and Welfare issues shall be identified prior to the design and placement of all campus signage to ensure appropriate placement of all internal and external signs in line with the relevant Act. These issues may include but are not restricted to: • Placement height of sign • Size of text • Use of colour and materials
4.6 Use of UniSA logo
The University of South Australia logo is a Registered Trade Mark and its use is controlled and managed by UniSA. The logo can be downloaded from the Marketing and Development Unit website for use in signage and other promotional and corporate material however strict use of the logo is maintained at all times.
Co-brand logos can also be used in signage designs which identify entities within UniSA like research centres, divisions and schools, and on occasion programs. Co-brands can also link UniSA with other organisations with which it has a partnership or relationship. The UniSA Logo Co-brand Framework provides the rationale and protocols for the branding format for the full range of collaborative alliances.
4.7 How to order signage
4.7.1 Customer forwards completed Signage request (FMU-065) or Door Plate Job Sheet (FMU-064) to Signage Officer which includes the relevant Cost Centre number and Authorisation Signature for expenditure
4.7.2 Signage Officer processes request form(s) and determines needs of
customer. 4.7.3 If signage request does not conform to corporate signage standards,
then Signage Officer will contact the customer to review the request and provide recommendations for appropriate signage.
4.7.4 Signage Officer may also visit site if appropriate to determine signage
requirements and discuss options for corporate standard signage or new signage design.
4.7.5 Signage Officer develops proof of signage design(s) ensuring integrity of
UniSA logo is maintained and forwards to customer for approval. 4.7.6 Customer provides email confirmation for approval of signage design
based on proof. 4.7.7 Signage Officer negotiates timeframe for signage to be manufactured
and installed and confirms location for installation. 4.7.8 Signage Officer proceeds with manufacture of signage request.
12
4.7.9 If signage product is a new design then Signage Officer shall update the
Campus Signage Manual accordingly.
5. References
• Standard Door Plate Job Sheet FMU-064
• Signage Request Form FMU-065
• UniSA Branding and Style Guide
• UniSA Logo Co-brand Framework
• OHS Purchasing Procedure
• Building Code of Australia
• Disability Discrimination Act
• How to order signage flowchart
13
No
No
Customer completesrelevant signage request form
and provides cost centre number and authorisation
for expenditure.
Signage O�cer processes request to determine needs of
customer.
Contacts customer todiscuss signage
options and provide recommendations.
Visit site if appropriate to review design and location
reqirements and provide recommendations if
appropriate.
Does signage request conform to corporate
standards?
Yes
Is customer happy with signage
design and cost?
Discuss issues with
customer and todetermine a
solution as required.
Signage O�cernegotiates timeframe for
manufacture and installation, con�rming
location for sign.
Signage O�cerproceeds with
manufacture and install of signage request.
Campus Signage Manual is updated with any new
signage design .
Signage Request Procedure Flow Chart
Signage O�cer develops proof ensuring integrity of
logo and forwards to customer for approval.
Yes
14
SOP-FM-107
STANDARD OPERATING PROCEDURE: Requesting Commercial
Signage 1. Introduction
This procedure has been developed to provide University stakeholders and Commercial service providers with appropriate information for placing commercial on University campuses.
2. Purpose The purpose of this procedure is to provide efficient and effective processes for requesting commercial signage on University campuses by commercial service providers. This procedure applies to all internal and external customers of the University of South Australia.
3. Definitions
Commercial signage is signage which is not documented in the Campus Signage Manual and which is associated with a commercial group. Commercial provider(s) are any entity associated with the University of South Australia that has a commercial focus, and/or any entity which has a commercial presence on a University campus.
4. Procedure
4.1. Types of Commercial Signage
Examples of commercial signage may include but are not limited to: • Identification and/or image signage for the commercial group. • Amenity signage which is associated with a commercial group. • Advertising signage.
UniSA is committed to adhering to the Disability Access and Occupational Health, Safety and Welfare guidelines regarding the design and placement of all campus signage. 4.2 Approval process
• The Director of Facilities Management or their representative shall advise the
commercial service provider of approval or otherwise once application for requested signage is received.
• All requests for commercial signage shall be referred to the Facilities Management Unit’s Commercial Services for recommendation to the Director: Facilities Management Unit.
15
• The Facilities Management Unit shall advise the commercial services provider of associated charges once application for commercial signage request is approved.
• Signage requirements that identify and/or are specific to a commercial customer shall be the responsibility of the respective commercial group and shall be funded by that group.
• Current market rates shall apply to all commercial signage unless otherwise directed in the formal contract negotiations.
4.3 Errors and Omissions Any costs associated with errors and/or omissions to signage requests by the commercial service provider shall be charged to the respective commercial customer’s group.
4.4 Commercial Signage Documentation
• Commercial service providers requiring a signage presence on University
campuses should make an application to the Facilities Management Unit: Commercial Services.
• A formal written agreement shall be established for commercial signage on University campuses in all instances.
• A commercial signage agreement pro-forma shall be developed by the Facilities Management Unit and utilised to ensure both parties adhere to agreement guidelines.
• Information contained in the agreement shall include but not restricted to: • Payment for signage design, construction and installation. • Cleaning and maintenance. • Replacement due to vandalism and/or general wear and tear. • Scope of sign i.e. Material, height, text etc. • Placement / location of sign(s) • Time frames for which action should be taken.
4.5 Requesting Permanent Commercial Signage 4.5.1 Commercial service provider contacts the Facilities Management Unit to discuss
signage requirements and forwards request in writing to the Commercial Services Manager, FMU.
4.5.2 Commercial Services reviews signage specifications and design and providers
recommendation to Director of Facilities Management for final approval. 4.5.3 If the Facilities Management Unit does not approve signage, feedback is provided
to the commercial service provider and the customer is required to submit a revised plan incorporating recommendations from the Facilities Management Unit.
4.5.4 Ongoing maintenance and cost implications for the signage shall be considered as
part of the Licence and Lease Agreement with UniSA.
16
4.5.5 Commercial services provider arranges manufacture and installation of signage and advises Facilities Management Unit of contractor details, timing and installation requirements for approval.
4.5.6 Facilities Management Unit follows Contractor Management procedure and
advises Commercial Services Provider and Facilities Coordinator of impending work.
5 References • Contractor Management Procedure • Contractor Permit to Work
17
Commercial Service Provider complets form PRO-004 commer-
cial Signage Request, gains required signatures and forwards
it to Commercial Services Manager, FMU.
Signage is recommended to the Director of FMU for
�nal approval.
Commercial Service Provider arranges for the construction of
signage and advises FMU of contractor details, timing and installation requirements for
approval.
Commercial Services approves contractor who will provide and install signage.
Commercial Signage Request Procedure Flow Chart
Commercial Services reviews signage
speci�cations
Is signage approved?
Yes
Is signage approved of Director
FMU?
Feedback isprovided and customer
requested to submit revised plan.
No
Contact customer to discuss signage options and provide
recommendations.No
FMU follows Contractor Mangement Procedure and advises Commercial Service
Provider and Facilities Coordinator of impending work.
18
S I G N A G E R E Q U E S T F O R M S
1919
OFFICE USE
ONLY
OFFICE USE
ONLY
Signage Request Form FMU085 Updated June 09
CAMPUS
City East City West Magill Mawson Lakes
Whyalla/Mt Gambier External
CONTACT DETAILS
Name .....................................................................
Contact Number ................................................
Area ........................................................................
Date Requested ..................................................
Due Date ...............................................................
Cost Centre ..........................................................
Authorisation Signature of Cost Centre
Manager ...............................................................(NB requests will not be processed without a cost centre)
LOCATION Building ............................................................................
Level ..................................................................................
Wall/Area ......................................................................... (Please attach map when possible)
BILLING
Manufacture $ .....................................
Installation $ .....................................
Total $ .....................................
Install Billed to: SS / Prop / Customer
External Invoice Y / N
Book Out Date ..........................................
Signature .........................................................................
Signage Description………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………….……………………………
………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………
…
………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………
Signage Details
OFFICE USE
ONLY
JOB NUMBER ...................................................
File Name ..........................................................
GENERAL SIGNAGE. - JOB SHEET(Please �ll ALL unshaded area)
20
Room number Text on plate Door type Cost Cost Property School
Name .................................................................................. Ext’n ........................
Area / School ..........................................................................................................
Cost Centre Code ..................................................................................................
Order date .............................................. Due date .............................................
STANDARD DOOR PLATE JOB SHEET
* Old : 2 or 3 seperate plates joined to make one sign with blue or black text
* New : single plate with metallic charcoal text
Door Plate Request Form FMU 064
TOTAL
OFFICE USE
ONLY
OFFICE USE
ONLY
Job number .....................................................................
Location .............................................................................
Booked Out ..........................
Signed ..................................................................................
$ ............................................... (School)
$ ............................................... (Property
line1: ....................................................................................................................................................
line2: ....................................................................................................................................................
other: ....................................new or old
glass door door with window
solid door sliding door
............ ..............
OFFICE USE
ONLY
OFFICE USE
ONLY
current plate type*
line1: ....................................................................................................................................................
line2: ....................................................................................................................................................
other: ....................................new or old
glass door door with window
solid door sliding door
............ ..............
OFFICE USE
ONLY
OFFICE USE
ONLY
current plate type*
line1: ....................................................................................................................................................
line2: ....................................................................................................................................................
other: ....................................new or old
glass door door with window
solid door sliding door
............ ..............
OFFICE USE
ONLY
OFFICE USE
ONLY
current plate type*
line1: ....................................................................................................................................................
line2: ....................................................................................................................................................
other: ....................................new or old
glass door door with window
solid door sliding door
............ ..............
OFFICE USE
ONLY
OFFICE USE
ONLY
current plate type*
line1: ....................................................................................................................................................
line2: ....................................................................................................................................................
other: ....................................new or old
glass door door with window
solid door sliding door
............ ..............
OFFICE USE
ONLY
OFFICE USE
ONLY
current plate type*
21
P e r m a n e n t S t a n d a r d C a m p u s S i g n a g e
T e c h n i c a l S p e c i fi c a t i o n
2222
2323
Technical Specifications
P-CM-01
Permanent Standard Campus Signage
Campus Map Type A
Wall Mounted
Frutiger
Prominent external location to be negotiated with andapproved by Property Unit
Fixed to A-Frame or wall using appropriate hidden fittings bynegotiation with Property Unit
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
Campus Map Type A
2424
Technical Specifications
P-CM-05
Permanent Standard Campus Signage
Campus Map Type B
Bollard
Frutiger
At key/prominent campus entry points, exact location to benegotiated with and approved by Property Unit
Transfer facing. City West: Dulux RMA Gold UniSAspecial colour used for backing of Bollard sign.All other campuses use Reflex blue for backing of sign.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
3mm mild steel plates seam welded atedges and paint finished Reflex Blue
3mm naturalanodised aluminiumface panels,pin fixed proud
150mm diam.Nominalbore CHS weldedto internal cleats
Logo-Cast ColourDeep Blue (050)to match reflex blue
Anodised Aluminium
Campus Map Type B
2525
2626
Technical Specifications
P-SS-05
Permanent Standard Campus Signage
Campus Street Sign Type A
Long Flag
Frutiger. Size shall be dependant upon number of text lines on flag,i.e 1 line-70mm, 2 & 3 lines-40mm. Upper/lower in all instances.
At key directional locations
Destination: The street signs used to show the distance betweenAustralia and other countries is to be similar to the Oslo sign.The countries shape in silver and a red dot for the capital.The country name in reflex blue frutiger medium and the distancein reflex blue frutiger small all centered.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
900mm
180mm
60mm 840mm
40mm
40mm
70mm
40mm
Campus CentralSecurity
70mm
Campus CentralCafeteria40mm
40mm BuildingA
40mm
70mmLibrary40mm Building
C40mm
City West, City East, MawsonLakes, Magill and Whyallastreet signs:Galvanised poles and alloy signclamps.The plates have a white vinylbackground with reflex bluelettering.
The sign itself can be purchasedfrom Heatpac, and they alsosupply all the clamps and boltsto fit.
Campus Street Sign Type A
2727
Technical Specifications
P-SS-01
Permanent Standard Campus Signage
Campus Street Sign Type B
Short Flag
Frutiger. Size shall be dependant upon number of text lines on flag,i.e 1 line-70mm, 2 & 3 lines-40mm.
At key directional locations
Destination: The street signs used to show the distance betweenAustralia and other countries is to be similar to the Oslo sign.The countries shape in Reflex blue and a red dot for the capital.The country name in reflex blue frutiger medium and the distancein reflex blue frutiger small all centered. On long flag.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
750mm
City West, City East, MawsonLakes, Magill and Whyallastreet signs:Galvanised poles and alloy signclamps.The plates have a white vinylbackground with reflex bluelettering.
The sign itself can be purchasedfrom Heatpac, and they alsosupply all the clamps and boltsto fit.
60mm 690mm
70mm
70mm
70mm180mm
180mm 40mm
40mm
40mm 40mm
40mm
180mm50mm
40mm
Campus Street Sign Type B
2828
2929
Technical Specifications
P-DB-01
Permanent Standard Campus Signage
Directory Board Type A
Building Directory Board
Frutiger / charcoal
Prominent location in main ground floor entries of each building
Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
Radius = 1600mmHeight of panel = 1300mm
550mm
20mm20mm
C
D
E
F
A
B
C
D
E
F
A
G
H
B
I
18 mm thick HMR, MDF panel 1800mm H x 700mmW finished in satin, automotive acrylic lacquer tomatch PMS 285.
2mm thick, satin natural anodised aluminium panel1400mm H x 650mm W rolled to specified radius andadhesive fixed with V.H.B. double sided tape andsilicon adhesive.
1.2mm thick zinc anneal panel, finished in metallicsilver automotive acrylic lacquer, with radius to faceand double edge returns to both vertical sides.Size 1300mm H x 550mm W. Key hole fix to faceof panel A.
16mm thick MDF split batton, screw & glue fixed torear of panel A.
16mm thick MDF split batton, mechanically fixed towall with suitable fixings, to suit wall type.
16mm thick MDF spacer strip fixed to rear of panel A
90mm high, UniSA logo cut in 1.6mm thick, No. 4,
satin finish stainless steel and adhesive fixed topanel A, where shown.
Lettering in corporate Frutiger font as shownFrutiger font as shown Building Name 40mm
high lettering. 1.6mm thick, No. 4,
Metallic Charcoal lettering in corporate Frutiger font.Size and justification as per 1:1 layout herewith.
G
H
I
D
A
CB
UniSA
Directory Board Type A
satin finish stainless steel and adhesive fixed topanel A, where shown.
3030
Technical Specifications
P-DB-02
Permanent Standard Campus Signage
Directory Board Type A - Free Standing
Directory Board
Frutiger 65 / Metalic Charcoal
Prominent location
Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
Catherine Helen Spence(CS) Building
LibraryDIRECTORY
Bolted to ground
660mm
460mmBehind Panal
1750mm(1745mm Skin)1645mm x 575mm
1545mm Backing(1645mm Enclosed)
75mm
Double Sided
Directory Board Type A - Free Standing
3131
Technical Specifications
P-DB-05
Permanent Standard Campus Signage
Directory Board Type B
Floor Directory Board 1
Frutiger
Prominent location
Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
A
D
B
1100mm
20mm
20mm
Radius = 3200mm Height of panel= 450mm
C
C
A
B
C
D
E
F
ROOM
R2 - 01-R2 - 12
2Academics' Offices
Administrative Suite
Computer Pool
CRC for WaterQuality & Treatment
Head of School
Microelectronics Centre
Reception
Research Laboratory: Analysis & Sensors & Electrochemistry
Teaching Laboratories: Analytical Chemistry Physical Chemistry Transfer Operations
Tutorial Room
School of Chemical Technology
R2 - 50-R2 - 62
R2 - 41
R2 - 42
R2 - 41B
R2 - 41C
R2 - 47
R2 - 43
R2 - 45
R2 - 31R2 - 29R2 - 38
R2 - 36
ROOM
Exit - Link to Building Q
Lifts to Level 2
Postgraduate Students Room
Stairs to Level 2
Teaching Laboratories: Inorganic Chemistry Organic Chemistry
R2 - 48
R2 - 55R2 - 55
ROOM
Teaching Laboratories: First Year Chemistry
A
K
BJ
G
I
H Bonython Jubilee Building
D
E
F
G
H
K
18 mm thick HMR, MDF panel 875mm H x1550mm W finished in satin,automotive acrylic lacquer to match PMS 285.2mm thick, satin natural anodised aluminiumpanel 550mm H x 1200mm Wrolled to specified radius and adhesive fixedwith V.H.B. double sided tape and siliconadhesive.1.2mm thick zinc anneal panel, finished inmetallic silver automotive acrylic lacquer,with radius to face and double edge returnsto both vertical sides.Size 450mm H x 1100mm W.Key hole fix to face of panel A.16mm thick MDF split batton, screw & gluefixed to rear of panel A.16mm thick MDF split batton, mechanicallyfixed to wall with suitable fixings,to suit wall type.16mm thick MDF spacer strip fixed to rear ofpanel A125mm high, UniSA logo cut in 1.6mm thick,No. 4, satin finishstainless steel and adhesive fixed topanel A, where shown.60mm high ‘Building name‘ cut in 1.6mmthick No. 4 stainless steel adhesive fixed topanel A, where shown, upper and lower case.207mm high 'Floor No.’ cut in 1.6mm thickNo. 4 stainless steel, adhesive fixed to panelA, where shown.Metallic Charcoal lettering incorporate Fruitiger font.Size and justification as per 1:1 layoutherewith.1.6mm thick satin, natural anodisedaluminium panel 420mm H x 300mm Wadhesive fixed 6mm proud of panel A,where shown.
I
J
Directory Board Type B
3232
Technical Specifications
P-DB-10
Permanent Standard Campus Signage
Directory Board Type C
Floor Directory Board 1
Frutiger
Prominent location
Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
A
B
C
D
E
F
G
H
18 mm thick HMR, MDF panel 875mm H x1550mm W finished in satin,automotive acrylic lacquer to match PMS 285.2mm thick, satin natural anodised aluminiumpanel 550mm H x 1200mm Wrolled to specified radius and adhesive fixedwith V.H.B. double sided tape and siliconadhesive.1.2mm thick zinc anneal panel, finished inmetallic silver automotive acrylic lacquer,with radius to face and double edge returnsto both vertical sides.Size 450mm H x 1100mm W.Key hole fix to face of panel A.16mm thick MDF split batton, screw & gluefixed to rear of panel A.16mm thick MDF split batton, mechanicallyfixed to wall with suitable fixings,to suit wall type.16mm thick MDF spacer strip fixed to rear ofpanel A125mm high, UniSA logo cut in 1.6mm thick,No. 4, satin finishstainless steel and adhesive fixed topanel A, where shown.60mm high ‘Building name‘ cut in 1.6mmthick No. 4 stainless steel adhesive fixed topanel A, where shown, upper and lower case.207mm high 'Floor No. cut in 1.6mm thickNo. 4 stainless steel, adhesive fixed to panelA, where shown.Metallic Charcoal lettering incorporate Fruitiger font.Size and justification as per 1:1 layoutherewith.
I
J
Directory Board Type C
D
B
470mm
20mm
20mmHeight of panel= 450mm
C
C
A
University of South Australia
School of Chemical Technology
R2 - 48
R2 - 55R2 - 55
ROOM
BJ
GD
E
F
H BUILDING R
Academics' Offices
Administrative Suite
Computer Pool
CRC for WaterQuality & Treatment
Head of School
Microelectronics Centre
Reception
Research Laboratory: Analysis & Sensors & Electrochemistry
Teaching Laboratories: Analytical Chemistry Physical Chemistry Transfer Operations
Tutorial Room
Exit - Link to Building Q
Lifts to Level 2
Postgraduate Students Room
Stairs to Level 2
Teaching Laboratories: Inorganic Chemistry Organic Chemistry
R2 - 50-R2 - 62
R2 - 41
R2 - 42
R2 - 41B
R2 - 41C
R2 - 47
R2 - 43
R2 - 45
R2 - 31R2 - 29R2 - 38
R2 - 36
ROOM
3333
20mm
The space between the extrusion on the twosides and the bottom will need to be far enoughapart to fit 3xA4 transparencies.
Clear plastic covering to hold the transparenciesin place, needs to fit tight to the curve.
20mm20mm 100mm
H channel plastic extrusion,clear acrylic slides into grooves
70x85mmsilver logo
30mm Frutiger
800mm
Clear Plastic Extrusion withsilver vinyl on the top, fixedwith double sided tape
natural anodisedaluminium backing
Space Blue backing board
180mm300mm
100mm 700mm
Technical Specifications
P-DB-15
Permanent Standard Campus Signage
Directory Board Type D
Staff Directory Board
Frutiger
Adjacent to Directory Boards Types A-C (note 2m clear zone),otherwise to be approved by Property Unit
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
UniSA40mm Frutiger
(H202 Section 1.5mm)
Font for the Staff transparencies to be frutiger or the closest font to that. Approximately 13-14 names should be included on each A4 transparency.
Directory Board Type D
3434
Technical Specifications
P-DB-17
Permanent Standard Campus Signage
Directory Board Type F
Floor Directory Board
Frutiger / charcoal
Prominent location in main ground floor entries of each building
(Up-side down large FA sign)
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
500mm
1.0mm Natural Ancodised Facefixed with double sided tape
Backing board is powder coated to matchReflex Blue using courtaulds Colour space Blue Gloss MJ008A
UniSA
80ish mm20 mm
450mm
50mm50mm
Level 1
20mm gap from backingboard on each side
Back plate is a double sidedcurved Galvanisedenvelope 20mm depth atends, 80ish depth at centre
Cathine Helen SpenceBuilding
Concealed Fittings to be used that suit surface application
Directory Board Type F
3535
D I R E C T O R Y I D E N T I F I C A T I O N S I G N S
3636
Technical Specifications
P-BI-01
Permanent Standard Campus Signage
Building Identification Type A
Alpha Sign
Frutiger. metallic colour Charcoal vinyl (027)
Prominent external location on main facade of building exactlocation to be negotiated with and approved by Property UnitSign to be 600x600x20mm natural anodised
Concealed fixings to be used that suit surface application.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
600mm
320mm
600mm
90mm
40mm
120mm
40mm
Building Identification Type A
3737
Technical Specifications
3mm thickStainless Steel satin finish
P-BI-05
Permanent Standard Campus Signage
Building Identification Type B
Name on Building
Frutiger 75. Font size shall be determined through consultationwith customer and Property/Services Units. Usually 110mm
Prominent external location on main facade of building exactlocation to be negotiated with and approved by Property Unit
Background of lettering should provide suitable contrast forease of reading. Direction should be sought from Property Unitif contrast is unsuitable.
Concealed Fixings to be used that suit surface application.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
CENTENARY BUILDING
Building Identification Type B
3838
Technical Specifications
3100mm
2000mm
100mm
200mm
800mm
Logo- to match reflex blue
Anodised Aluminium
Text-charcoal
70mm
150mm diameternominal boreCHS 3mm thick
500mm diameterconcrete pier
P-BI-10
Permanent Standard Campus Signage
Building Identification Type C
Stand Alone Bollard Sign
Frutiger. Charcoal. Font size shall be determinedon application
Prominent external location adjacent main entrance/forecourtto building, exact location to be approved by Property Unit
UniSA logo shall match Reflex Blue Standard.Integrity of logo and text shall adhere to standardsspecified in Your Guide to our Visual Identity-UniSA Design Standards.Text information and layout shall be determined in consultation withcustomer and Property Services Units upon application.
Refer diagram above
3mm mild steel plates seam welded atedges and paint finished Reflex Blue
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
3mm natural anodisedaluminium face panels,pin fixed proud 150mm diam.
Nominal bore CHSwelded to internal cleats160 Kilos weight
Building Identification Type C
3939
4040
Technical Specifications
P-CI-01
Permanent Standard Campus Signage
Corporate Identification Sign Type A
Wall Mounted
Frutiger
Prominent wall location adjacent toCorporate Area key entry point
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
1800
mm
Text-colour - Metallic Charcoal
650mm50mm
63mm
25mm from main frame
236.5mm50mm
50mm
265mm
80mm
Anodised Aluminium (1.0)
Logo Colourto match reflex blue
C A M RCentre
for AdvancedManufacturing
Research
40mm 40mm
Curved panel fixedproud of back panel
297mm
325mm 325mm
Centred
Corporate Identification Sign Type A
4141
Technical Specifications
P-CI-05
Permanent Standard Campus Signage
Corporate Identification Sign Type B
Stand Alone Bollard Sign
Frutiger
At key entry point to Corporate Area
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
Technical Drawing not currently available for this sign type
Corporate Identification Sign Type B
4242
������������� ��������
�������
������������������������������
������������������������������!���
"������#$����%��������
��������*+;<��� ��;�������>���
��������?�������@�Q�������"�������;X��������$����%����Z
���������������� �����
������������������
���������
����������
���������������������
���������
������������
��!����"����#
��Q���[��������������������
\���������#��@���
������������������������������!���
������������� ���������������� ���University of
South Australia������������� ���
������������ ���University of
South Australia
43
������������� ��������
������*
������������������������������
���������������������������������������
]Z*��������������
��������*+;<��� ��;������������
^�����������%���������������������%�����������
���������������� �����
������������������
���������
����������
���������������������
���������
������������
��!����"����#
��Q���[��������������������
\��[�����������_��������%������`�����
���������������������������������������
������������� ��� ������������� ���University of
South Australia
44
4545
Schoolof Nursing &Midwifery
Technical Specifications
400mm
700mm
120mm
500mm
50mm 50mm
50mm
50mm
350mm
50mm
20mm gap from backingboard on each side
Back plate is a double sidedcurved Galvanisedenvelope. 20mm depth atends, 80ish mm depth at centre
Type cap height to be aminimum of 18mm in Charcoalmetallic upper and lower case
Face printed on removable adhesive clear vinyl (502mm x 352mm)
1.0mm Natural Anodised Facefixed with double sided tape
Backing board is powder coated to matchReflex Blue using courtaulds Colour SpaceBlue Gloss MJ008A
Logo Colourto match Reflex Blue
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-FA-01
Permanent Standard Campus Signage
Functional Area ID Sign Type A
Small
Frutiger.18mm min.Metallic Charcoal
Prominent wall location at key entry point to division/school/centre/institute/unit.
Integrity of logo and text shall adhere to standards specified inYour Guide to our Visual Identity-UniSA Design Standards.
Concealed Fittings to be used that suit surface application
50mm
20mm
80mm
Functional Area ID Sign Type A
4646
Schoolof Nursing &Midwifery
Technical Specifications
500mm
900mm
180mm
700mm
80mm 50mm
50mm
80mm
450mm
50mm
20mm gap from backingboard on each side
Back plate is a double sidedcurved Galvanisedenvelope. 20mm depth atends, 80ish mm depth at centre
Type cap height to be aminimum of 18mm in Charcoalmetallic upper and lower case
Face printed on removable adhesive clear vinyl (702mm x 452mm)
1.0mm Natural Anodised Facefixed with double sided tape
Backing board is powder coated to matchReflex Blue using courtaulds Colour SpaceBlue Gloss MJ008A
Logo Colourto match Reflex Blue
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-FA-01
Permanent Standard Campus Signage
Functional Area ID Sign Type B
Large
Frutiger.30mm min.Metallic Charcoal
Prominent wall location at key entry point to division/school/centre/institute/unit.
Integrity of logo and text shall adhere to standards specified inYour Guide to our Visual Identity-UniSA Design Standards.
Concealed Fittings to be used that suit surface application
50mm
20mm
80mm
Functional Area ID Sign Type B
4747
4848
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-22
Permanent Standard Campus Signage
Blade Amenity
Priority Access (Computer)
Frutiger / 22mm / Reflex Blue 754
Priority Access Computer. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
50mm
28mm
140mm
200mm
Priority Access (Computer)
4949
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-81
Permanent Standard Campus Signage
Blade Amenity
Access / Female Toilet
Frutiger / 16mm / Reflex Blue 754
Above Entrance door to Access Female Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Access Female Toilets
5050
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-89
Permanent Standard Campus Signage
Blade Amenity
Access / Male Toilet
Frutiger / 16mm / Reflex Blue 754
Above Entrance door to Access Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Access / male Toilet
5151
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-83
Permanent Standard Campus Signage
Blade Amenity
Access Toilet / Baby Change Room
Frutiger / 15mm / Reflex Blue 754
Above Entrance door to Change Room Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Access Toilet / Baby Change Room
5252
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-85
Permanent Standard Campus Signage
Blade Amenity
AccessToilets
Frutiger / 16mm / Reflex Blue 754
Above Entrance door to Access Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Access Toilets
5353
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-96
Permanent Standard Campus Signage
Blade Amenity
Access / Toilet
Frutiger / 16mm / Reflex Blue 754
Above Entrance door to Access Female / Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Access / Toilet
5454
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-84
Permanent Standard Campus Signage
Blade Amenity
Access / Toilet / Shower
Frutiger / 16mm / Reflex Blue 754
Above Entrance door to Access Toilet / Shower Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Access / Toilet / Shower
5555
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-50
Permanent Standard Campus Signage
Blade Amenity
Security
Frutiger / 22mm / blue (006) Calplus in vinyl
Above entrance door to Security Office. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Security
5656
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-55
Permanent Standard Campus Signage
Blade Amenity
Security Phone
Frutiger / 22mm / blue (006) Calplus in vinyl
Above Security phone. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Security Phone
5757
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-91
Permanent Standard Campus Signage
Blade Amenity
Study Room
Frutiger 30mm / 702 Burgundy Red
Above entrance door to Study RoomBottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Study Room
5858
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-34
Permanent Standard Campus Signage
Blade Amenity
Staff Room
Frutiger 65 / 20mm / 702 Burgundy Red
Above entrance door to Staff Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Staff Room
5959
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-90
Permanent Standard Campus Signage
Blade Amenity
Seminar Room
Frutiger 65 / 20mm / 702 Burgundy Red
Above entrance door to Seminar Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Seminar Room
6060
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-92
Permanent Standard Campus Signage
Blade Amenity
Quiet Study Area
Frutiger 30mm / 702 Burgundy Red
Above Quiet Study AreaBottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Quiet Study Area
6161
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-94
Permanent Standard Campus Signage
Blade Amenity
Books 000-###
Frutiger 30mm / 702 Burgundy Red
In appropriate location.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Books 000-###
######
6262
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-93
Permanent Standard Campus Signage
Blade Amenity
Journals
Frutiger 30mm / 702 Burgundy Red
Above entrance door to JournalsBottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Journals
6363
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-95
Permanent Standard Campus Signage
Blade Amenity
New Books & Journals
Frutiger 30mm / 702 Burgundy Red
Above entrance door to New Books & Journals.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
New Books & Journals
6464
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-33
Permanent Standard Campus Signage
Blade Amenity
Meeting Room
Frutiger 65 / 17mm / 702 Burgundy Red
Above entrance door to Meeting RoomBottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Meeting Room
6565
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-30
Permanent Standard Campus Signage
Blade Amenity
Lecture Theatre
Frutiger / 20mm / 702 PF Burgundy Red (Awery)
Above entrance door to Lecture Theatre.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
Lecture Theatre
6666
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-15
Permanent Standard Campus Signage
Blade Amenity
Computer Room
Frutiger / 20mm / 702 PF Burgundy Vinyl (Avery)
Above entrance door to computer room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
Computer Room
6767
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-16
Permanent Standard Campus Signage
Blade Amenity
Printer Pool
Frutiger / 25mm / Burgundy 702 (Avery)
Above entrance door to above Printer Pool. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Printer Pool
6868
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-13
Permanent Standard Campus Signage
Blade Amenity
Computer Pool
Frutiger / 20mm /Burgundy 702
Above entrance door to computer room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
Computer Pool
6969
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-14
Permanent Standard Campus Signage
Blade Amenity
Computer Barn
Frutiger / 20mm / Burgundy 702
Above entrance door to computer barn.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Computer Barn
7070
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-32
Permanent Standard Campus Signage
Blade Amenity
Augmented Hearing Lecture Theatre
Frutiger 65 / 20mm & 12mm / 702 PF Burgundy Red & Reflex Blue 754
Above entrance door to Lecture Theatre.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Augmented Hearing Lecture Theatre
7171
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-18
Permanent Standard Campus Signage
Blade Amenity
Adaptive Technology Suit
Frutiger / 17mm / Burgundy 702
Above entrance door. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
108mm
210mm
50mm
28mm
65mm 155mm
112mm
52mm
Adaptive Technology
7272
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-30
Permanent Standard Campus Signage
Blade Amenity
Tutorial Room
Frutiger / 20mm / 702 PF Burgundy Red (Awery)
Above entrance door to Tutorial Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
Tutorial Room
7373
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-70
Permanent Standard Campus Signage
Blade Amenity
Phone
Frutiger / 30mm / cast colour Royal Blue (006) in vinyl
Above Public Telephone. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Phone
7474
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-86
Permanent Standard Campus Signage
Blade Amenity
Toilets
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Toilets
7575
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-75
Permanent Standard Campus Signage
Blade Amenity
Male Toilet
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Male Toilet
7676
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-80
Permanent Standard Campus Signage
Blade Amenity
Female Toilet
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Female Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Female Toilet
7777
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-87
Permanent Standard Campus Signage
Blade Amenity
Female / Male Toilet
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Female / Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Female / Male Toilet
7878
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-60
Permanent Standard Campus Signage
Blade Amenity
Shower
Frutiger / 25mm / cast colour Copenhagen blue (756) in vinyl
Above entrance door to Shower. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
50mm
28mm
98mm112mm
98mm112mm
173mm
69mm
Shower
7979
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-88
Permanent Standard Campus Signage
Blade Amenity
Female / Male Toilets and Showers
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Female / Male Toilets and Showers. Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Female / Male Toilets and Showers
8080
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-76
Permanent Standard Campus Signage
Blade Amenity
Male Toilet / Showers
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Male Toilet / Showers. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Male Toilets / Shower
8181
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-77
Permanent Standard Campus Signage
Blade Amenity
Female Toilet / Showers
Frutiger / 22mm / cast colour Copenhagen blue
Above Entrance to Female Toilet / Showers. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Female Toilets / Shower
8282
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-81
Permanent Standard Campus Signage
Blade Amenity
Change Room
Frutiger / 20mm / Copenhagen Blue 91587
Above Entrance door to Change Room Facilities. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Change Room
8383
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-40
Permanent Standard Campus Signage
Blade Amenity
Mail Room
Frutiger / 22mm / copenhagen blue (756) Cast colour in vinyl
Above entrance door to Mail Room. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Mail Room
8484
Technical Specifications
Signage Reference Number
Sign çlassification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-35
Permanent Standard Campus Signage
Blade Amenity
Lift
Frutiger / 30mm / copenhagen blue (756) Cast colour in vinyl
Above Lift Car entrance. Bottom edge of sign of approximately2200mm above floor level
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape. The graphic for this blade sign shall conform toAS2899.1 Public Information Symbol Signs Part 1-GeneralInformation Signs, Standard Symbol Sign:120
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
145mm145mm
Lift
8585
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-65
Permanent Standard Campus Signage
Blade Amenity
Stairs
Frutiger / 30mm / cast colour Copenhagen blue (756) in vinyl
Above entrance to Stairs. Bottom edge ofsign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
50mm
28mm
98mm112mm
98mm112mm
173mm
69mm
Stairs
8686
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-20
Permanent Standard Campus Signage
Blade Amenity
First Aid
Frutiger / 22mm / green (005) Calplus in vinyl
Above entrance door to First Aid. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
100mm
100mm
First Aid
8787
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-10
Permanent Standard Campus Signage
Blade Amenity
Cafeteria
Frutiger / 40mm / Turquoise (731HP) Avery
Above entrance door to cafeteria. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
8888
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-05
Permanent Standard Campus Signage
Blade Amenity
Bar
Frutiger / 40mm / Turquoise (731 HP) Avery
Above entrance door to bar. Bottom edge of sign of approximately2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Bar
8989
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-19
Permanent Standard Campus Signage
Blade Amenity
Book Returns
Frutiger 65 / 15mm / Turquoise 731
In appropriate location. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
108mm
210mm
50mm
28mm
65mm 155mm
112mm
52mm
Book Returns
9090
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-21
Permanent Standard Campus Signage
Blade Amenity
Multi Access Suite
Frutiger / 18mm / Turquoise 731
Above entrance door to Multi Access Suite. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
140mm
200mm
50mm
28mm
Multi Access Suite
9191
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-17
Permanent Standard Campus Signage
Blade Amenity
Student Common Room
Frutiger 65 / 15mm / Turquoise 731 (Avery)
Above entrance door to Student Common Room. Bottom edge of sign ofapproximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Student Common Room
9292
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-25
Permanent Standard Campus Signage
Blade Amenity
International Students Room
Frutiger / 18mm / Turquoise (731 HP) Avery
Above entrance door to International Students Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
International Students Room
9393
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-45
Permanent Standard Campus Signage
Blade Amenity
Prayer Room
Frutiger / 22mm / Turquoise (731) Avery
Above entrance door to Prayer Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
98mm112mm
98mm112mm
173mm
69mm
50mm
28mm
Prayer Room
9494
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-46
Permanent Standard Campus Signage
Blade Amenity
Male Prayer Room
Frutiger / 13mm / Turquoise (731)
Above entrance door to Prayer Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Male Prayer Room
9595
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-47
Permanent Standard Campus Signage
Blade Amenity
Female Prayer Room
Frutiger 65 / 13mm / Turquoise (731)
Above entrance door to Prayer Room.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Female Prayer Room
9696
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-BA-48
Permanent Standard Campus Signage
Blade Amenity
Chaplain
Frutiger 65 / 20mm / Turquoise (731)
Above entrance door.Bottom edge of sign of approximately 2200mm above floor level.
The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.
The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.
145mm
292.5mm
65mm
7.5mm
70mm15mm 60mm
32.50mm
7.5mm 130mm 7.5mm
32.50mm10mm
112mm108mm
155mm65mm
210mm
52mm
50mm
28mm
Chaplain
9797
D O O R S I G N S
9898
City West, City East and Whyalla Campus-Natural Anodised plateswith black helvetica lettering cast colour Black (008) withblack components.
Magill-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.
Mawson Lakes-White powder coated plates with Palatinoblue lettering cast colour Reflex Blue and whitecomponents.
Underdale-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-01
Permanent Standard Campus Signage
Door Sign Type A
Two Part Door Sign
Refer Details above 25mm text
On door leafBottom edge of sign of approximately 1500mm above floor level.
Concealed fixings.
merlin
450mmx40mm
A1-03A Lecture Theatre
joiner
25mm text 25mm text
Door Sign Type A
150 x 140mm
9999
Dr Anna Ciccarelli300mm
Technical Specifications
P-DS-25
Permanent Standard Campus Signage
Staff Pigeon Hole Names Sign
Staff Pigeon Hole Name
Helvetica Extended Medium (009) and compressed to 79%.Cast Colour Black (008)
On pigeon hole unit under each person’s pigeon hole
Natural Anodised plate with black end clips.Signs mainly used at City West
Siliconed/double sided tape
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
20mm
Staff Pigeon Hole Names Sign
100100
Dr Anna Ciccarelli300mm
Technical Specifications
P-DS-26
Permanent Standard Campus Signage
Staff Pigeon Hole Names Sign Type B
New Style Door Palte - DOuble Line
Frutiger 65 / 12mm / Metallic Charcoal
Centred on pigeon hole door
Natural anodized aluminium plate
Concealed fixings, attached to pigeon hole with 3M double-sided
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
30mm
Staff Pigeon Hole Names Sign Type B
101101
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-07
Permanent Standard Campus Signage
Door Sign Type D
New Style Door Plate - Double Line
Frutiger 65 / 12mm / Metallic Charcoal
On door leafBottom edge of sign of approximately 1500mm above floor level.
Concealed fixings.
A1 -03A
Text Height: 12mm; Font: Frutiger 65; Colour: Matallic Charcoal
600mm
30mm 30mm
50mm
1 Part Door Plates, 2 lines of text
Natural anadized aluminium plate
Mr Joe BloggsLecturer
(Text to be centered top to bottom)
Door Sign Type D
102102
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-06
Permanent Standard Campus Signage
Door Sign Type C
New Style Door Plate - Single Line
Refer Details above 25mm text
On door leafBottom edge of sign of approximately 1500mm above floor level.
Concealed fixings.
A1 -03A Lecture Theatre
Text Height: 25mm; Font: Frutiger 65; Colour: Matallic Charcoal
600mm
30mm 30mm
50mm
1 Part Door Plates, Single line of text
Natural anadized aluminium plate
Door Sign Type C
103103
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-05
Permanent Standard Campus Signage
Door Sign Type B
Three Part Door Sign
Refer Detail above 12mm text
On door leafBottom edge of sign of approximately 1500mm above floor level.
Concealed fixings.
merlin twin
450mmx20mm
joiner
150mmx40mm
City West, City East and Whyalla Campus-Natural Anodised plateswith black helvetica lettering cast colour Black (008) withblack components.
Magill-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.
Mawson Lakes-White powder coated plates with Palatinoblue lettering cast colour Reflex Blue and whitecomponents.
Underdale-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.
25mm text 12mm text
Door Sign Type B
104104
Technical Specifications
P-DS-23
Permanent Standard Campus Signage
Name Plate
Reception/Counter Name Plate
Frutiger, 15mm upper/lower case. Metallic CharcoalLogo silver vinyl
Front counter, reception desk or office desk
Integrity of logo and text shall adhere to standards specified inYour Guide To Our Visual Identity-UniSA Design Standards.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
Materials: Natural AnodisedAluminiumReflex Blue PerspexPieces placed together usingdouble sided tape
200mm
230mm
Name here
20mm
25mm
45mm
50mm 36mm
50mm
10mm
30mm
40mm
18mm
15mm
18mm
35mm
5mm
10m
m
50m
m50
mm
45
5mm
105105
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-10
Permanent Standard Campus Signage
Door Sign Type C
Access Toilet
Reflex Blue / White
On door leaf (centred)l.
Natural anodised plate
Siliconed/double sided tape
150mm
150mm
130mm
Door Sign Type C
106106
Technical Specifications
P-DS-15
Permanent Standard Campus Signage
Door Sign Type D
Female Toilet
Copenhagen Blue
On door leaf (Centred)
Natural Anodised plate
Siliconed/double sided tape
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
120mm150mm
150mm
Door Sign Type D
107107
Technical Specifications
P-DS-20
Permanent Standard Campus Signage
Door Sign Type E
Male Toilet
Copenhagen Blue
On door leaf (Centred)
Natural Anodised plate
Siliconed/double sided tape
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
120mm150mm
150mm
Door Sign Type E
108108
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-30
Permanent Standard Campus Signage
Frosted Vinyl Logos to Glazed Doors
OHS Uni-Logo Frosting
Standard University Logo
As per diagram
Frosted Vinyl direct-stick to door
Shield & Text Height 150mm
Type AGlazed Doors Between630mm & 830mm
Type BGlazed Doors Between830mm & 1010mm
Type CGlazed Doors Between
1010mm & 1280mm
Shield & Text Height 200mm Shield & Text Height 250mm
OHS Uni Logo Frosting for Glass Doors
Frosted Vinyl Logos to Glazed Doors
109109
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-09
Permanent Standard Campus Signage
Vinyl Door Text in Hawke Building
Hawke Building sign Type ID 7
Frutiger 45 / 38mm / Matt Black (Avery 721)
As per diagram
Vinyl direct-stick to door
A1 -03A
Text Height: 38mm; Font: Frutiger 45; Compression 90%; Character Spacing 4; Colour: Matt Black (Avery 721)
1750mm
Dr Anna CirrarelliPVC & Vice President: International and Development
The CrowleyReseach Room
20mm
87mm
Hawke Building sign Type ID 7
110110
Technical Specifications
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
P-DS-08
Permanent Standard Campus Signage
Door Sign Type E
Hawke Building new Style Door Plate - Double Line
Frutiger 55 & 45 / 10 & 8mm / White
On door leafBottom edge of sign of approximately 1500mm above floor level.
Concealed fixings, attached to door with 3M double-side tape
A1 -03A
Text Height: 8 & 10mm; Font: Frutiger 55 & 45; Colour: White
600mm
Frutiger 55
50mm
Hawke Building 1 Part Door Plates, 2 lines of text
Door Plate is painted to match Dulux Luck
Dr Anna CirrarelliPVC & Vice President: International and Development
Frutiger 45
10mm text8mm numerals
Door Sign Type E
111111
F I R E A N D S A F E T Y S I G N S
112112
Technical Specifications
P-FS-01
Permanent Standard Campus Signage
Fire and Safety Sign Type A
Evacuation Sign
Frutiger
On Floor Directory Boards Type B-C on allocated panel
Orientation of evacuation map to suit location ofdirectory board so that north is in the correct direction
Film shall suit material surface to allow for easy replacementas required
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
Technical details not currently available for this sign type
Fire and Safety Sign Type A
113113
C A R P A R K E N T R Y S I G N S
114114
Top panel to be fixed using double sided tapeor anodised riveted
natural anodisedaluminium backing
Space Blue Powder coatedbacking board
Technical Specifications
P-CP-01
Permanent Standard Campus Signage
Car Park Entry Sign Type A
Stand Alone Bollard Type
Frutiger
At key carpark entry points
Only include those items/codes on the sign from the legend ofAllocated Parking For, which are applicable to the actual carpark
Hidden fittings for placement of two sheets. Poles are 2 metresin length with 1 metre enveloped between sheets.
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
100mm
20mm
1100mm
120mm
150mm
1100mm
1100mm150mm70mm
150mm
20
00
mm
17
00
mm
280mm
70mm
80mm type
55mm type
Cast Colour Ochre/Red (289)
CalpusGreen (005)Brown (010)Purple (075)Blue (006)Cherry (029)Fire Red (504)Orange (003)
Car Park Entry Sign Type A
115115
O T H E R S I G N S O F I N T E R E S T
116116
Technical Specifications
P-AC-01
Permanent Standard Campus Signage
Acrylic Sign Type A
Frosted acrylic
Frutiger 65 / best fit / Metallic Charcoal
Mounted to the wall in location as discussed with customer
Size can be altered if required
Fixed using brushed aluminium CAB fixings, or double-sided tape
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
800mm
180mm
Wall Mounted Acrylic Sign Single Sided
Borrow Here
Aluminium Fixings
117117
Technical Specifications
P-AC-02
Permanent Standard Campus Signage
Acrylic Sign Type B
Frosted acrylic
Frutiger 65 / best fit / Metallic Charcoal
Mounted to the wall in location as discussed with customer
Size can be altered if required
Fixed using brushed aluminium CAB fixings, or double-sided tape
Signage Reference Number
Sign Classification
Sign Type
Sign Style
Font Type/size/colour
Placement
Other Remarks
Fixing Method
800mm
180mm
Hanging Acrylic Sign Double Sided
Borrow Here
Aluminium Fixings
118118