calibration - abacus instrumentsabacusinstruments.com/images/abacus_brochure_print_final.pdf ·...

36
Catalogue Measurement • Data Logging • Calibration • Control • Alarms Measurement • Data Logging • Calibration • Control • Alarms

Upload: tranmien

Post on 12-Feb-2018

265 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Cat

alog

ue

Measurement • Data Logging • Calibration • Control • Alarms

Measurement • Data Logging • Calibration • Control • Alarms

Page 2: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

CalibrationCalibration Certificates to traceable standards

can be supplied with all temperature instruments and on site calibration services can

be offered where required.

Telephone

01462 638200for more details cont

entsAbacus Instruments specialise in the manufacture and supply of

temperature and humidity monitoring equipment. We can supply low cost solutions to help you and your customer meet the ever changing legislations.

The systems Abacus Instruments offer range from low cost Wireless (RF) Dataloggers supplied with software up to multi channel logging systems capable of using GPRS, Ethernet, GSM (mobile phone) or radio connections which eliminates the need of expensive cable runs, thus lowering your installation costs.

Abacus Instruments Limited also supply the latest alarm systems for Pharmaceutical, Blood, Plasma and Cryogenic Storage. Helping your customer meet the stringent MHRA Regulations.

We constantly update the product range, to keep up with the latest developments and regulations. You can view the complete range of products at www.abacusinstruments.com.

If you need any advice then please phone 01462 638200

Page 3: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

cont

ents Circular Chart Recorders

Models for temperature, humidity, pressure, voltage and current.

Temperature AlarmsRefrigeration and general purpose Alarms. Blood Storage Alarms.

Large LED DisplaysTwo and three digit displays for temperature, humidity and process variables.

Miniature LoggersSingle and multi-channel.

Logging SystemsWireless or wired probes, GPRS, SMS text options.

Temperature Controlled TransportersMedibox.

Calibration ServicesOn Site.In House.

Controllers Refrigeration and Process Control.

Hand Held ThermometersPortable battery operated.

page 2

page 4

page 9

page 10

page 13

page 18

page 22

page 28

page 30

Page 4: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ2

Mini-Chart Temperature Recorders

• Flexible Bulb & Capillary Sensor

• Chart Rotation 12 / 24 Hour,

7 / 31 Day

• 4 year Battery Life (typical)

• Door Lock (2 Keys)

• Simple Installation (no wiring)

• Panel or Wall Mount

Mini-Chart temperature recorders are a popular choice for monitoring and recording storage temperatures in a wide range of applications.

They provide a clear, permanent temperature record, which is easy to read.

The paper disks are convenient to store and provide a continuous record of temperature history.

Low cost consumables make the Mini-chart an attractive solution to meeting “Due Diligence” requirements.

Technical Specification

Dimensions 144 x 144 x 67 mm

Panel Cut-out 138 x 138 mm

Capillary Length 2.5m or 5.0m (2.5 Standard)

Sensor dimensions 76 long x 9mm Diameter

Pen life 6 months (typical)

Accuracy + / - 1.5%

Chart Motor Battery 3V Lithium AA (typical life 3-4 years)

Chart Rotation (Factory Set) 12 Hour, 24 Hour, 7 Day, 31 Day

Chart Diameter 125mm

For further information contact:-

Abacus Sales Office

01462 638200Telephone

Pen (shown above in upright postion) lifts for ease of nib removal

Page 5: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 3

Mini-Chart MR Temperature Recorders

• User Selectable Temperature Ranges °C;

• Battery Operated or 12Vdc*

• PT1000 Sensor• User Selectable Rotation Speed

12 Hour, 24 Hour, 7 Day, 31 Day• Door Lock (2 Keys)• Simple Installation (no wiring)• Panel or Wall Mount

The Mini-chart MR chart recorder gives the consumer greater flexibility, as all the parameters are user selectable. You can now select the temperature range and rotation speed, so you can get the best range for your application.

The unit can also include Hi & Lo Alarms† using one common relay output and an audible

alarm. The Mini-chart MR can be connected to a BMS (Building Management System) or to an optional GSM Unit autodialler. In the event of an alarm this would send text alerts to mobile phones or pre-recorded messages to mobile phones or land lines.

Technical Specification

Dimensions 144 x 144 x 67 mm

Panel Cut-out 138 x 138 mm

Sensor Length 3m

Sensor Type PT1000 or Voltage Input

Pen life 6 months (typical)

Accuracy + / - 1.5%

Chart Motor Battery 2 x 3.6V Lithium

Chart Rotation 12 Hour, 24 Hour, 7 Day, 31 Day

Temperature Range User Selectable

Chart Diameter 125mm

1 -35 to +15 2 -25 to +25 3 -10 to +20 4 -5 to +25 5 0 to -50 6 -50 to -100 7 0 to +50 8 +50 to +100 9 0 to 5 Volts dc

* Alarm model only† Must be specified at time of order

Pen (shown above in upright postion) lifts for ease of nib removal

Page 6: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ4

MPA-2A - Temperature Critical Storage Alarm

• High & Low Temperature Alarm

• Mains Failure Alarm

• Door Alarm

• Defrost Input

• Full Battery Back Up

• Door Lock (2 Keys)

• Panel or Wall Mount

The MPA-2A has been specifically designed for temperature critical storage applications. It has simple to use menus, a clear LCD display, alarm sounder and volt free changeover alarm contacts. The alarm output can be connected to building management systems, a GSM telemetry unit to send text alerts to mobile phones or to an autodialler to send pre-recorded messages to mobile phones or landlines.

The MPA-2a provides clear audible and high visibility alarms. Connections are via vibration proof sprung terminal strip with clear permanent terminal labelling. The internal backup battery provides audible and high visibility alarms even if the power has failed.

The door is lockable to prevent unauthorised tampering.

The MPA-2A is the perfect companion to our Mini-Chart range providing a comprehensive solution for temperature recording and alarming applications.

Technical Specification

Dimensions 144 x 144 x 67 mm

Panel Cut-out 138 x 138 mm

Sensor PT1000

Resolution 0.1°C

Accuracy 0.5°C

Temperature Range -99 to +99°C

Door Contact Input Internally powered for volt free contacts

Defrost Contact Input Internally powered for volt free contacts

Alarm / Defrost Delays / Mute 2 to 90 minutes

Audible Alarm Sounder

Visual Alarm High Intensity LED Array

Outputs (Relay Contacts) Volt Free NO / C / NC (fail safe to NC) 1.25A / 240 Vac

Power Supply 240 Vac / 12, 24 Vdc

Page 7: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 5

BSA - Blood Storage Alarm

• Alert & Action

• Alarms Mains Failure

• Door Alarm

• Full Battery Back Up

• Door Lock

• Panel Mount

The BSA has been specifically designed to be M.H.R.A compliant for Blood Storage Refrigerators.

It has two temperature alarm functions, one ALERT and one ACTION.

It uses PT1000 probes which monitor ambient air temperature in the refrigerator and the second probe can be placed in a glycol solution which simulates the product (Blood).

The BSA provides clear audible and high visibility alarms. Connections are via vibration

proof sprung terminal strip with clear permanent terminal labelling. The internal backup battery provides audible and high visibility alarms even if the power has failed.

The door is lockable to prevent unauthorised alarm acceptance and the Action Alarm is latching with acceptance via a “Supervisors” key switch.

The BSA is the perfect companion to our Mini-Chart range providing a comprehensive M.H.R.A Compliant solution for Blood Storage temperature recording and alarming.

Technical Specification

Dimensions 144 x 144 x 67 mmSensor 1 – Air Probe PT1000Sensor 2 – Product Probe PT1000

Resolution 0.1 ºCAccuracy 0.5 ºCTemperature Range -5°C to 25°CAlert Alarm (Air Probe) Factory Set to 2°C and 8°CAlert Alarm Delay Adjustable 2 to 20 mins (Key Locked)Action Alarm (Product) Factory Set to 2°C and 6°CAction Alert Delay No DelayDoor Contact Input Volt Free ContactsAudible Alarm Sounder – Piezo BuzzerVisual Alarm High Intensity LED ArrayOutputs ( Relay Contacts) Volt Free 1.25A/240VacPower Supply 240Vac / 12 / 24 Vdc

Page 8: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ6

Protector A - Temperature Critical Alarm Unit

• High & Low Temperature Alarm

• Mains Failure Alarm

• Alarm Contact Input

• Alarm Override Contact Input

• Full Battery Back Up

• Wall Mount

The Protector has been specifically designed for temperature critical storage applications. It has simple to use menus, a clear LCD display, alarm sounder and volt free changeover alarm contacts. The alarm output can be connected to building management systems, a GSM telemetry unit to send text alerts to mobile phones or to an autodialler to send pre-recorded messages to mobile phones or landlines.

It is housed in a robust wall mounted enclosure which, if required can be sealed to IP65. Connection is by vibration proof sprung terminals mounted inside a protected terminal compartment. Knockouts are provided for up to 4 compression glands.

The internal backup battery provides audible and high visibility alarms even if the power has failed.

Technical Specification

Dimensions 165 x 160 x 85mm

Sensor PT1000

Resolution 0.1°C

Accuracy 0.5°C

Temperature Range -99 to +99°C

Alarm Contact Input Internally powered for volt free contacts

Alarm Override Contact Input Internally powered for volt free contacts

Alarm / Alarm Override / Mute Delays 2 to 90 minutes

Audible Alarm Sounder

Visual Alarm High Intensity LED Array

Outputs (Relay Contacts) Volt Free NO / C / NC (fail safe to NC) 1.25A / 240 Vac

Power Supply 240 Vac / 12, 24 Vdc

Page 9: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 7

Protector 6 - Six Channel Temperature Alarm Unit

• 6 x High & Low Temperature Alarms

• Mains Failure Alarm

• Alarm Contact Input

• Alarm Override Contact Input

• Full Battery Back Up

• Wall Mount

The Protector 6 has the same technical specification as the Protector A but it can have up to 6 temperature inputs. Each of the 6 channels has independent high and low alarm set points and alarm delays. (Note, the alarm contact is common to all 6 channels).

It has simple to use menus, a clear LCD display, alarm sounder and volt free changeover alarm contacts. The alarm output can be connected to building management systems, a GSM telemetry unit to send text alerts to mobile phones or to an autodialler to send pre-recorded messages to mobile phones or landlines.

The Protector 6 is housed in a robust wall mounted enclosure which, if required can be sealed to IP65. Connection is by vibration proof sprung terminals mounted inside a protected terminal compartment. Knockouts are provided for up to 4 compression glands.

The internal re-chargeable backup battery provides audible and high visibility alarms even if the power has failed.

Technical Specification

Dimensions 165 x 160 x 85mm

Sensors Up to 6 x PT1000

Resolution 0.1°C

Accuracy 0.5°C

Temperature Range -99 to +99°C

Alarm Contact Input Internally powered for volt free contacts

Alarm Override Contact Input Internally powered for volt free contacts

Alarm / Alarm Override / Mute Delays 2 to 90 minutes

Audible Alarm Sounder

Visual Alarm High Intensity LED Array

Outputs (Relay Contact) Volt Free NO / C / NC (fail safe to NC) 1.25A / 240 Vac

Power Supply 240 Vac / 12, 24 Vdc

Page 10: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ8

GSM Telemetry System

SD1+ Autodialler

• Remote Control from a mobile phone

• Easy to install and configure using SMS commands (no PC required).

• 2 digital inputs (volt free)

• 2 relay outputs rated at 240V 6A

• User can set input and output names

• Up to 5 mobiles per input

• Outputs controlled by SMS text message

• Request status via SMS

• Standalone Dual Band GSM/GPRS Engine

• Accepts all major SIM Cards

• Waterproof enclosure rated IP68

• Automatically sends SMS message when input activated

• 12/24Vdc Power Supply Inputs

The Abacus GSM Telemetry system is the ideal partner for the Abacus MPA-2a and Protector Series of alarm units, as it can be used to send text alerts to 5 mobile phones when the storage unit goes into

alarm. This means that you can now have your cold rooms, fridges and freezer giving 24 hour alarms. So even when your building is unattended you can feel safe in the knowledge that your business is covered.

The Abacus SD1+ can be used with any of the Abacus range of Alarms. The SD1+ is connected into a phone landline system and it will send out a pre-recorded message to 4

preprogramed phone numbers alerting to an alarm situation. It continues to alert people of the alarm, until it is acknowledged by the message recipient.

• The user can re-record the messages as often as required

• The messages recorded notifies up to 4 programmed numbers

• Up to 40 seconds of recording time per message

• Call acknowledgement facility

• The SD1+ is simple for the end user with clear on-screen instructions to guide them through recording the messages

• New eight-character Starburst LCD display

• BABT approved.

Page 11: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 9

Large Super Bright LED Displays

Technical Specification

Inputs LD

Dimensions (Case) 250 x 160 x 65mm DeepLD Display Height 60mmXLD Display Height 100mm

Number of Digits (LD) 3 Number of Digits (XLD) 2 Range (LD) -99.9 to +99.9Range (XLD) -99 to +99Accuracy +/- 0.5%Power Supply 240 / 110Vac (Internal Mains Supply) or 12 / 24Vdc

Temperature -99.9 to +99.9°C -99 to +99°C0 to 1 volt dc Scalable to any value between -99.9 to +99.9 -99 to +990 to 5 volts dc Scalable to any value between -99.9 to +99.9 -99 to +99°

0 to 10 volts dc Scalable to any value between -99.9 to +99.9 -99 to +990-20 mA Scalable to any value between -99.9 to +99.9 -99 to +994-20 mA Scalable to any value between -99.9 to +99.9 -99 to +99

• 100 or 60 mm 7 Segment Displays

• 2 or 3 Digit

• High Visibility

• Remote Sensor (Class A PT1000)

• Temperature, Humidity, or Process inputs

• Scalable Display

• High and Low Alarms

The Abacus Range of displays are capable of using a host of process inputs and displaying the values. Which make them ideal not only for temperature displays but process industries where clear indications of parameters are essential.

This range of displays has been designed to give maximum visibility in areas of high ambient light. The large LED digits (100mm xLD / 60mm LD) make for easy reading at a distance.

They can be supplied with or without Alarms. The alarm option gives both High and Low alarms with separate volt free contacts. When in alarm the display will flash alternatively between the value and either HI or LO giving a clear indication of a fault.

The enclosure is tough and durable and if required can be supplied sealed to IP65.

XLD

Page 12: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ10

Mini-Print – 2 Channel Logger with printer

• 2 Channel Logging

• Thermal Printer

• Intelligent Sensors

• Alarm Output

• PC Connectivity

Mini-print is a 2 Channel printer logger which is a popular choice for monitoring and recording storage temperatures in a wide range of applications. Including the food, pharmaceutical, laboratory and refrigerated transportation industries.

It can be used as a standalone logging and printing unit with alarms or connected to a PC via RS232 and the Mini-print software,

which allows you to view, save and print the stored data via the PC.

The alarm output can be connected to building management systems or using an optional GSM unit can send text alerts to mobile phones or an auto dialler which can send pre-recorded messages to mobile phones or land lines.

Technical Specification

Dimensions 144 x 144 x 83 mm

Panel Cut-out 132 x 132 mm

Temperature Range -40°C to 125°C

Sensor DS18B20

Display LCD

Resolution 0.1

Storage Capacity 16128 Samples

Interface RS232

Printer Thermal Printing

Power Supply 12-24 Vdc / 3A

Page 13: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 11

Therma Data Loggers

• Waterproof to IP66/67

• Meets EN 12830, S & T, C & D ,1

• Range -40°C to 85°C or 125°C

• Rugged Construction

• Alarm Indication (Max or Min)

• LCD Display (not TB)

• Internal* and / or External Probes*

This range of waterproof rugged Temperature Loggers offers a low cost solution for monitoring temperature applications such as Pharmacy and Food Storage Fridges and Cold Rooms etc. They can be supplied with (TD) or without (TB) a LCD Display giving real time readings.

They are impervious to condensation and will withstand hose down cleaning. Being

fully portable they can be packed amongst product on pallets or in shipping containers to provide an accurate temperature profile of any journey.

They have either internal or external probes (see product code spec)*. The external probes can be fixed or detachable with a water proof connector.

Technical Specification

Range -30°C to 85°C /125°C

Resolution 0.1°C

Accuracy +/- 0.5°C

Memory 4000 Readings

Sample Rate 0.1 to 255 minutes

Battery 3.6 volt ½ AA lithium

Battery Life 18 months @ 20°C

ThermaData Software

The ThermaData Software is a comprehensive but easy to use suite, which combines logger set-up with data display. The Logger is placed into the cradle and all data can be uploaded to the PC for display and archive.

*model specific (see our website for further details www.abacusinstruments.com)

Page 14: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ12

This range of waterproof loggers offers professional specification solutions for monitoring temperature, humidity, and process signals.

They come with a range of channel and input options, are impervious to condensation and will withstand hose down cleaning (not RH models).

Being fully portable they can be packed amongst product or in shipping containers

to provide an accurate temperature profile of any journey. They have a locking eyelet for security.

They have either internal or external probes (see product code spec).

For additional input combinations including voltage, current and pulse please phone our sales office for details.

MODEL ATX/ATV-01 ATX/ATV-02 ATX/ATV-03 ATX/ATV-04

• Waterproof to IP67 (Not RH)

• Rugged Construction

• Alarm Indication (Max or Min)

• LCD Display (ATV)

• IR Software Link

• Magnet Start Option

• 3 Year Battery Life

Professional Series Logger

Channels 1 x Temperature 1 x Temperature 2 x Temperature 2 x Temperature

Int Sensor ATX ATV

-40 to +80°C -30 to +70°C

N/A N/A -40 to +80°C -30 to +70°C

Range Ext Sensor N/A -90 to +260°C -90 to +260°C -90 to +260°C

Resolution 0.1°C 0.1°C 0.1°C 0.1°C

Accuracy + / - 0.4°C + / - 0.4°C + / - 0.4°C + / - 0.4°C

Memory 32,000 32,000 32,000 32,000

Sample Rate 10 sec to 24 Hours 10 sec to 24 Hours 10 sec to 24 Hours 10 sec to 24 Hours

Battery Life 3 years 3 years 3 years 3 years

Display 2 x LED / LCD 2 x LED / LCD 2 x LED / LCD 2 x LED / LCD

Dimensions ATX ATV

93x64x26 93x64x29

93x64x26 93x64x29

93x64x26 93x64x29

93x64x29 93x64x29

Page 15: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 13

The T4 GSM Text Logger and Alarm unit allows the user the ultimate in accessibility to their data no matter where they are located. Using GSM technology the operator can retrieve the stored data from any PC* installed with the Abacus T4 software.

The T4 allows you to centralise your companies’ data storage to the head office enabling you to keep all your records in one location.

Its intelligent features allow maximum protection for temperature sensitive product.

The T4 alarm functions can be set to send “alarm texts” to up to 6 mobile phones. Warnings of refrigeration plant failure, mains failure, doors open as well as temperature alarms can, if required, all be sent as text messages.

If computers are not your thing, then we can do it all for you. From our Bedfordshire Office we dial up your T4, upload the data, print it and then post it to you for your records.

*PC must be fitted with modem (can be supplied with unit)

• 1 to 4 Channels• Temperature Fault Text Message Alarm• Mains Fail Text Message Alarm• Remote Interrogation Via Text• Remote Upload Via Modem• Battery Back up• Digital Display

T4 GSM Text Logger & Alarm

Technical Specification

Sensors DS18B20

Temperature Range - 40 to + 99°C

Resolution 0.25°C

Accuracy +/- 0.5°C

Temperature Logging Frequency Every 2 to 60 minutes

Storage Capacity 1600 readings, 42 Days storage (4 sensors every 15 minutes)

Switch Inputs 2 x Volt Free Contact

Alarms Temp Hi / Lo 2 x Switch Open 2 x Switch Tamper Power Fail

Local Alarms Red LED, Yellow Status Internal Sounder

Battery Backup 1 Hour (Text “Power Failure”) Sent after 10 seconds

Digital Display 2 Rows 16 Character LCD

Power Supply 12 / 24 Vdc (Mains Adapter Supplied)

Page 16: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ14

Total Wireless & Internet Logging Solutions

COLD CHAIN LOGISTICS

PHARMACEUTICAL

EFFLUENT

FACTORY PROCESSES

HEALTHCARE

TRANSPORT

ENVIRONMENTAL

UTILITY MONITORING

FOOD DISTRIBUTION

MACHINE MONITORING

ENERGY USAGE

REMOTE SITES

ABACUS GUARDIAN™

To achieve a complete monitoring and alarm system one or more Guardian Units are installed in the field either as a fixed, or mobile system. Each GU has up to 14 analogue inputs and 10 digital inputs which can be wired to any industrial sensor. Each of these sensor inputs can have alarm values set. There are also relays incorporated to provide local control or alarm actions. The relays can be associated with any input or controlled remotely by internet or mobile phone. There are also GU’s for use with radio sensors and pulse counter inputs.

The GU’s communicate to the web server using their onboard GPRS modem so that hard wired connection to a network is not required. They have on board battery

backup to operate up to 24 hours without external power. These can be kept charged by DC or AC power, or by solar cells.

Data and configuration are accessed by logging onto the web site using password and logon ID. The web site also provides facilities to set local control or alarm parameters, manage passwords and access permissions, input telephone numbers and email addresses for alarm notification and calibration of the inputs. Alarm messages can be sent to selected mobile phones by SMS text message or email.

Instantaneous data and alarms may also be obtained from the GU’s automatically or on request from authorized mobile phones.

Page 17: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 15

Total Wireless & Internet Logging Solutions

Data collection and measurement

3 Collect data from fixed, remote or mobile sites

3 Monitor multiple points and parameters using any industrial probes and sensors

3 All standard industry analogue signals supported (4-20mA, 0-5V, PT100 etc)

3 Data logging units can be mains, DC or solar powered with battery backup

3 Housed in robust waterproof enclosures for the most demanding applications

3 Calibrate and configure sensors, data collection and alarms over the internet

Data storage and analysis

3 Units download all data to server via mobile phone system or via satellite

3 Access data on server using any computer or mobile phone with an internet connection

3 Data available for analysis, reports and archiving on a central web site

3 View data collected from multiple sites and vehicles at any time

3 User authorises access by central managers, site supervisors, customers, regulatory bodies

3 Information can be accessed from anywhere in the world by anyone with authorisation

3 User name and password protected with user set security levels

Alarms and control

3 Local control relays and alarms to alert staff on site

3 Immediate alarm messages by email or via SMS to mobile phones

3 Instantaneous data can be retrieved by SMS

3 Log and view alarm responses so remedial actions are confirmed

Future Compatibility

3 No software to buy or maintain

3 No compatibility issues with future Windows or Mac computer operating systems

3 No on-site security issues as it is not necessary to connect units to local networks

3 No ‘multiple user’ software licensing issues

Abacus Instruments manufacture and supply many configurations of Guardian Systems to suit all applications, Please call our applications specialists for a FREE CONSULTATION to advise the most suitable and cost effective solution for your application.

For more information and for a demonstration of the user software

please go to www.measure-online.com

Page 18: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ16

T120 Wireless Data Centre

Possible Uses;* Temperature* Humidity* Co2* Oxygen* Nitrogen* Smoke

* Electricity Usage * Water Usage* Gas Usage* Power Indication* Light Levels* Airflow

* Door Opening Indicators* Air Pressure* Water Levels* Liquid Flow Measurements* Plant Failure Notification* Wireless Gas & Gas Leak Detection

The T120 DATA centre is a wireless tempera-ture & environmental monitoring system with a vast array of capabilities in a format that is easily understood and easy to use.

With the added benefits; of being easy to install, that alarms at your defined set points; that is accessible for information and that can

cover a broad range of monitoring applications with a high degree of precision.

When connected to a PC via the internal Ethernet port the Wireless DATA centre starts to show its flexibility and capacity. The in built web server allows the system to be viewed from any PC without dedicated software.

• Completely Stand Alone operation• On board Ethernet with HTTP server• Receives input from upto 120 Wireless Sensors• HACCP compliant Recorders• 1 minute recording intervals• Up to 10 years on board data storage• Vast array of environmental factors can be monitored

Technical Specification

Dimensions 200mm (W) x 140mm (H) 55mm (D)

Power Supply 5V dc via external Power Supply

Operating Temperature 0°C to +40°C

Operating System Embedded

Alarm Internal Sounder / Volt free contract / Email / Real time status via display

Frequency 433 Mhz (UK/Europe) Licence free band

Radio Module Power 10mW maximum

Communications Bi-directional

Protocol Proprietary

Sensor Up to 8 hardwired temp and/or volt free digital inputs. Up to 20, 8 channel modules providing temp and volt free digital input. Up to 120 devices providing temperature, Humidity, 4-20mA, pulse count and volt free digital inputs.

Display High Contrast 128 x 64 graphics display

Storage 2gb providing 1 yrs archived data at 1m interval

Page 19: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 17

• Up to 50 points • LAN Receiver for Multilog System• Temperature & Humidity• Email Alerts for alarm conditions• Stores Temperature even when

the PC is turned off.• Easy to use software.

The Abacus radio datalogging system uses wireless base station dataloggers to receive and store radio transmitted values from up to 50 temperature, humidity and carbon dioxide sensors.

With the AB500 or AB1000 base stations powered by a battery backed DC power adapter it is possible to log readings without a computer connected. Each sensor refreshes it’s value every 45 Seconds (approx). With one sensor the maximum PC independent recording length is about 110 days. With 10 Sensors it is still 11 days.

Data can be retrieved from the base stations via USB using the software provided. Alternatively, the AB1000 can be connected to a private network and accessed via its onboard web server.

The easy to use software presents the temperature measurements with time and date graphically. The Software keeps track of the data over several years and will log data (in the background) as long as your computer is running. The logged measurements can be exported in several formats for further processing.

Sensors and receiver use a wireless communication system, working at 433MHz. Depending on surrounding building construction, a transmission range of up to 50 metres is possible for the standard sensors. Extended range sensors with up to 90m range are also available. Repeater stations are available to ensure complete coverage on large sites by re-transmitting sensor readings.

Wireless Transmitting Sensors

PC Connection Power Memory

AB-500 USB 5VDC 2MB (approx 200,000 readings)

AB-1000 USB and Ethernet 5VDC 2MB (approx 200,000 readings)

Sensor Type RangeT1 Ambient Temperature Sensor -30 to +80°C

T1-WP Waterproof Temperature Sensor -30 to +80°C

T1-50E Extended Range Ambient Temperature Sensor -30 to +80°C

T1-RH Temperature & Humidity Sensor -30 to +80°C, 10 to 90% RH

T1-EXT Temperature Transmitter with External Probe -30 to +80°C

T1-CO2 Carbon Dioxide Sensor 400ppm to 900,000ppm

REP01 Repeater Station

Datalogging Receiver Base Stations

Abacus Wireless Data Logging System

Page 20: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ18

Hand Held Thermometers

The low cost digital Multi-function thermometer is ideal for use in restaurants, bars and cafes. With an easy to read LCD display that shows both temperature and alarm set points.

The thermometer incorporates a display hold facility and a max/min memory

Function with an adjustable audible high/low temperature alarm.

Technical Specification

Technical Specification

Specification ThermaLite 1 Range -39.9°C to 149.9°C

Resolution 0.1°C / F

Accuracy +/- 0.5°C (-39.9 to 124.9°C)

Battery 3 Volt CR2032 Lithium coin cell

Battery Life 3000 hours

Sensor Type Thermistor

Display 10mm LCD

Dimensions Ø29mm x 246mm

Weight 45 gramsFREE traceable certificate of

calibration included

Specification ThermaLite 1 Range -49.9°C to 149.9°C

Resolution 0.1°C / F

Accuracy +/- 1°C (-20°C to 150°C)

Battery 1.5 volt AAA

Battery Life 5000 hours

Sensor Type Thermistor

Display Custom LCD

Dimensions 32mm x 86mm x 116mm

Weight 98 grams

ThermaLite Thermometer Multi-function ThermometerThe ThermaLite digital thermometer displays temperature over the range of -39.9°C to 149.9°C with 0.1°C resolution and an accuracy of +/- 0.5°C.

The ThermaLite is ideal for use within the catering industry as the case is a high impact ABS plastic which includes the Biomaster additive that reduces bacterial growth. The pointed Ø3.3 x 130mm stainless steel penetration probe is ideal for measuring the temperature of food and semi-solid materials.

Page 21: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 19

The differential digital thermometer allows the user to use two type K thermocouple probes simultaneously. The display can show probe T1 or T2 or the difference between probes. The thermometer features a custom CD display with °C, T1, T2, diff, hold, open circuit and low battery indication.

Each Kit Contains1 x Thermometer1 x Penetration Probe1 x Pipe Clamp Probe1 x ABS Carrying Case

Technical SpecificationSpecification 2202 Thermamite 5Range -49.9°C to 199.9°C -50°C to 550°CResolution 0.1°C 1°CAccuracy +/- 0.5°C +/- 1 % +/-1°C +/- 1 %Battery 9 volt PP3Battery Life 150 hoursSensor Type K ThermocouplesDisplay 12.7mm LCDDimensions 35mm x 73mm x 141mmWeight 300 grams

FREE traceable certificate of calibration included

HVAC Thermometer Kits

Hand Held Thermometers

Technical Specification

Specification Thermamite 1 Thermamite 5Range -49.9°C to 199.9°C -30°C to 300°CResolution 0.1°C 1°CAccuracy +/- 0.5°C +/- 1 digit +/-1°C +/- 1 digitSensor Type PT100 K ThermocoupleBattery 9 volt PP3Battery Life 500 hoursDisplay 12.7mm LCDDimensions 25mm x 68mm x 121mmWeight 410 grams

FREE traceable certificate of calibration included

Thermamite Thermometer 1 & 5The Thermamite digital thermometer displays temperature over the range of -49.9°C to 199.9°C (Thermamite 1) or -30°C to 300°C (Thermamite 5) with 0.1°C or 1°C resolution and an accuracy of +/- 0.5°C +/- 1°C respectively.

The Thermamite 1 & 5 incorporate a clear LCD display and come supplied with a permanently attached rigid pointed, stainless

steel food penetration probe (Ø3.3 x 108mm) and a 500mm connecting lead.

Page 22: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ20

Hand Held Thermometers

This low cost max/min and alarm fridge or freezer thermometer indicates temperature over the range of -49.9°C to 69.9°C. It features a large backlit LCD display, max/min memory function and an audible alarm.

It incorporates two temperature sensors, a remote water resistant probe with a one meter PVC lead and an internal sensor to monitor ambient temperature.

Technical Specification

Technical Specification

Specification CaterTempRange -49.9°C to 299.9°C

Resolution 0.1°C

Accuracy +/- 0.4°C (-50 to 199°C) +/- 1°C (200°C to 300°C)

Battery 3 x 1.5 volt AAA

Battery Life Minimum 5 years (10000 hours)

Sensor Type K thermocouple

Display 12mm LCD

Dimensions 25mm x 56mm x 128mm

Weight 130 gramsFREE traceable certificate of

calibration included

Specification Multi-functionRange -49.9°C to 69.9°C

Resolution 0.1°C / F

Accuracy +/- 1°C

Battery 1.5 volt AAA

Battery Life 5000 hours

Sensor Type Thermistor

Display Custom LCD

Dimensions 15mm x 52mm x 73mm

Weight 48 grams

CaterTemp Thermometer Fridge or Freezer Thermometer – With alarm & max/min functions The CaterTemp professional digital

thermometer is designed for the catering and food processing industry. The CaterTemp thermometer is housed in a robust ABS case that contains ‘Biomaster’ additive to reduce bacterial growth.

The thermometer is supplied with a permanently attached food penetration probe with a 130 mm pointed, stainless steel, stem and one meter coiled PU lead.

Page 23: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 21

Hand Held Thermometers

Technical Specification

Specification Mini water bathRange - Cool 0°C (20°C below ambient)

Range - Heat 56°C

Accuracy +/- 0.5°C (in stable 20°C ambient temperature)

Power 12 volt DC or 100 to 240 volt AC with adaptor

Power Consumption

20 watts cooling – 18 watts heating

Bath / cup capacity

300 millilitres

Dimensions 110mm x 130mm x 150mm

Weight 600 grams

Mini Calibration Bath

The mini temperature calibration bath is a safe compact, no frills, tabletop device that can cool liquid to 0°C (+/- 0.5°C) or heat water to 56°C (+/- 0.5°C). It can be used to check the accuracy of a thermometer and probe when used in conjunction a with a Reference Thermometer with current UKAS certificate of calibration. This provides a cost effective method to verify the calibration of your thermometers and probes.

High accuracy PT100 thermometer that is supplied with a 5-point UKAS Certificate of Calibration. The reference thermometer is ideal for comparison checking the calibration and accuracy of other thermometers and probes. It measures temperatures over the range of -199.9 to 199.9°C with a resolution of 0.01°C and an accuracy of +/-0.05°C.

Each calibration certificate indicates deviations from standards at -18, 0, 40, 70 and 100. However other ranges can be certified by arrangement with Abacus.

Technical SpecificationSpecificationRange -199.9°C to 199.9°CResolution 0.1°C Accuracy +/- 0.05°C (-30 to 150°C) otherwise +/- 0.1°CBattery 3 x 1.5 volt AAABattery Life 2000 hoursSensor Type PT100 1/10th DINDisplay 10mm LCDDimensions 25mm x 56mm x 128mmWeight 210 grams

A UKAS Certificate of Calibration is included

Reference Thermometer

Page 24: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ22

Technical Specification

Specification IC901 IC901ARange –50°C to 99°C –50°C to 99°C

Measurement Range -50°C to 99°C -50°C to 99°C

Display No decimal point * 2 digits + sign No decimal point * 2 digits + sign

Resolution 0.1°C or 1°C 0.1°C or 1°C

Accuracy better than 0.5% of end scale + 1digit

better than 0.5% of end scale + 1digit

Power • 12 V ~ , 12/24 V~ ±10% 50/60 Hz • 230V a ±10% 50/60 Hz

• 12 V ~ ±10% 50/60 Hz • 230V a ±10% 50/60 Hz

Analogue Inputs 1 PTC or NTC input (selectable through parameter)

1 PTC or NTC input (selectable through parameter)

Digital Outputs 1 SPDT 8(3)A 250V~ or SPDT 16A 250V ~

1 SPDT 8(3)A 250V~ or SPDT 15A 1HP 250V~

Dimensions 74x32 mm, depth 60 mm 74x32 mm, depth 60 mm

Serial Ports TTL for connection to Copy Card TTL for connection to Copy Card

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel) IP65 (Front Panel)

Alarm Not Available Present

Refrigeration Controllers

Elliwell IC 901& IC 901A - Heat/Cool Controller

IC901 & IC901A controllers are one-step devices capable of working for both hot and cold applications.

Eliwell EWTL 300

Technical Specification

Specification EWTL 300Display 2 and half digit LCD

Power Battery 1 x 1.5V LR44

Dimensions 48 x 28.6 mm, depth 13.5 mm

Accuracy +/- 1°C from 0°C to +40°C

Probe Connected to instrument, cable length 1.5m

Display Refresh 10 Seconds

Page 25: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 23

Refrigeration Controllers

IC915LX Controllers are electronic two-step devices, either dependent or independent or with neutral zone, used for the control of temperature, relative humidity and pressure.

IC 915 LX (NTC-PTC) Heat/Cool Controller

Eliwell ID400

Technical Specification

Specification IC915LX NTC/PTCRange NTC probe -50.0°C to 110.0°C

PTC probe -55.0°C to 140.0°C

Measurement Range -50°C to 140°C

Display No decimal point * 3 and a half digits + sign

Resolution 0.1°C or 1°C

Accuracy better than 0.5% of end scale + 1digit

Power • 12 V ~ , 12/24 V~ /24 V~ ±10% 50/60 Hz

• 110-115V~ / 220-230V~ ±10% 50/60 Hz

Analogue Inputs 1 PTC or NTC input (selectable through parameter)

Digital Inputs 1 clean contact at safety extra low voltage

Digital Outputs 2 x SPDT 8(3)A 250V~

Dimensions 74x32 mm, depth 60 mm

Serial Ports TTL for connection to Copy Card, TelevisSystem (Modbus Protocol)

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel)

Technical Specification

Specification Multi-functionRange -5°C to 55°C

Resolution 1°C

Accuracy +/- 1°C

Battery 230 VAC

Sensor Type NTC

Display Custom LCD

Dimensions 15mm x 32mm x 74mm

Weight 48 grams

Page 26: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ24

Refrigeration Controllers

Eliwell IC961

Eliwell IC974(LX)

IC 961 controllers are electronic two-step devices with defrosting functions.

IC974(LX) are designed for the management of cold rooms cooling functions, defrosting functions and evaporator fan control functions.

Technical Specification

Technical Specification

Specification IC961Range NTC probe -50.0°C to 110.0°C

PTC probe -55.0°C to 140.0°CMeasurement Range -55°C to 140°CDisplay No decimal point * 3 and a half digits + signResolution 0.1°C or 1°CAccuracy better than 0.5% of end scale + 1digitPower 12 V ~ / - , 12/24 V~ /24 V~ / - 12-36V - ±10% 50/60 HzAnalogue Inputs 1 PTC or NTC input (selectable through parameter)

Digital Inputs 1 voltage-free input (selectable through parameter)

Digital Outputs 1 SPDT 8(3)A 1/2HP 250V~ + 1 SPST 8(3)A 1/2HP 250V~

Dimensions 74x32 mm, depth 60 mm

Serial Ports TTL for connection to Copy Card

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel)

Specification IC974(LX)Display Range NTC probe -50.0°C to 110.0°C

PTC probe -55.0°C to 140.0°CMeasurement Range -55°C to 140°CDisplay No decimal point * 3 and a half digits + signResolution 0.1°C Accuracy better than 0.5% of end scale + 1digitPower 12 V ~ / - 10% 50/60 Hz

Analogue Inputs 1 PTC or NTC input (selectable through parameter)

Digital Inputs 1 voltage-free input (selectable through parameter)

Digital Outputs 1 SPDT 8(3)A 1/2HP 250V~ + 2 SPST 8(3)A 1/2HP 250V~ + 1 SPDT 5(3)A 1/4HP 250V~

Dimensions 74x32 mm, depth 60 mm

Serial Ports TTL for connection to Copy Card

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel)

Page 27: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 25

Refrigeration Controllers

ID 961 controllers are suitable for any application on refrigeration units at normal temperature.

Eliwell ID961(LX) – ID961/A – ID961/D

Technical Specification

Specification ID961(LX) IC961/A ID961/DDisplay Range –50°C to 99°C –50°C to 99°C NTC Probe –50°C to 110°C

PTC Probe -55°C to 140°C Measurement Range -50°C to 99°C -55°C to 99°C -55°C to 140°CDisplay No decimal point

* 2 digits + signNo decimal point * 2 digits + sign

No decimal point * 31/2 digits + sign

Resolution 0.1°C or 1°C 0.1°C or 1°C 0.1°C or 1°CAccuracy better than 0.5% of end

scale + 1digitbetter than 0.5% of end scale + 1digit

better than 0.5% of end scale + 1digit

Power • 12 V ~ , 12/24 V~ ±10% 50/60 Hz • 230V a ±10% 50/60 Hz

• 12 V ~ , 12/24 V~ ±10% 50/60 Hz • 230V a ±10% 50/60 Hz

• 12 V ~ , 12/24 V~ ±10% 50/60 Hz • 230V a ±10% 50/60 Hz

Analogue Inputs 1 PTC or NTC input (selectable through parameter)

1 PTC or NTC input (selectable through parameter)

1 PTC or NTC input (selectable through parameter) (defrost input)

Digital Outputs 1 SPDT 8(3)A 250V~ or SPDT 15A 250V ~ or SPDT 2HP

1 SPDT 8(3)A 250V~ or SPST 8(3)A or SPST 15A 1HP 250V~

1 SPDT 8(3)A 250V~ or SPDT 15A 1HP 250V~

Dimensions 74x32 mm, depth 59 mm

74x32 mm, depth 59 mm 74x32 mm, depth 59 mm

Serial Ports TTL for connection to Copy Card

TTL for connection to Copy Card

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel) IP65 (Front Panel) IP65 (Front Panel)

Serial Port LX Model Only

TTL for connection to Copy Card And TelevisSystem1 clean contact at safety extra low voltage3 and half digits + SIGN

Page 28: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ26

Refrigeration Controllers

Eliwell ID974 (LX)The ID974 controller range has been extended with the introduction of two new models. The ID974(LX) ‘switching’ can be powered from 95Vac to 240Vac. The ID974(LX) DCC (deep cooling cycle) combines blast chilling control with temperature control.

Technical Specification

Specification ID974(LX) Switching ID974(LX) DCC

Display Range NTC probe -50.0°C to 110.0°C PTC probe -55.0°C to 140.0°C

NTC probe -50.0°C to 110.0°C PTC probe -55.0°C to 140.0°C

NTC probe -50.0°C to 110.0°C -55°C to 140°C

Measurement Range -55°C to 140°C -55°C to 140°C

Display No decimal point * 3 and a half digits + sign

No decimal point * 3 and a half digits + sign

Resolution 0.1°C or 1°C 0.1°C or 1°C

Accuracy better than 0.5% of end scale + 1digit better than 0.5% of end scale + 1digit

Power 95 to 240V ~ 50/60 Hz 230V ~ +/- 10% 50/60 Hz

Analogue Inputs 2 PTC or NTC input (selectable through parameter)

2 PTC or NTC input (selectable through parameter)

Digital Outputs 1 SPDT 11A 2HP 250V~ + 1 SPST 8(3)A 250V~ + 1 SPST 8(3)A 250V~ or 1 SPST 5(2)A 250V

1 SPDT 8(3)A 250V~ + 1 SPST 8(3)A 250V~ + 1 SPST 5(2)A 250V~

Dimensions 74x32 mm, depth 60 mm 74x32 mm, depth 60 mm

Serial Ports TTL for connection to Copy Card or Modbus Protcol

TTL for connection to Copy Card or Modbus Protcol

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel) IP65 (Front Panel)

LX Models

Serial Ports TTL for connection to Copy Card And TelevisSystem

TTL for connection to Copy Card And TelevisSystem

Digital inputs 1 clean contact at safety extra low voltage

1 clean contact at safety extra low voltage

Page 29: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 27

Refrigeration Controllers

Eliwell thermoregulators in the Universal Controller series are ideal for all industrial applications requiring high precision temperature control, including the moulding of plastic materials, packaging and process control in the transformation of raw materials.

Eliwell EW4820 – EW4821 – EW4822

Technical Specification

Specification EW 4820 EW 4821 EW 4822

Measurement Range

According to probe used According to probe used According to probe used

Display No decimal point * 2 x 4 digits + sign

No decimal point * 2 x 4 digits + sign

No decimal point * 2 x 4 digits + sign

Resolution According to probe used According to probe used According to probe used

Accuracy According to probe used According to probe used According to probe used

Power 12/24 V ~ , 12/36 V~ ±10% 50/60 Hz or 95 - 240V a ±10% 50/60 Hz

12/24 V ~ , 12/36 V~ ±10% 50/60 Hz or 95 - 240V a ±10% 50/60 Hz

12/24 V ~ , 12/36 V~ ±10% 50/60 Hz or 95 - 240V a ±10% 50/60 Hz

Analogue Inputs 1 input (phone for options)

1 input (phone for options)

1 input (phone for options)

Digital Outputs 1 SPDT 3A 250V~ + or 1 SPST 2A 250V ~

1 SPDT 3A 250V~ + or 1 SPST 2A 250V ~

1 SPDT 3A 250V~ + or 1 SPST 2A 250V ~

Digital inputs Not available 1 clean contact at safety extra low voltage

1 clean contact at safety extra low voltage

Dimensions 48 x 48 mm, depth 113 mm

48 x 48 mm, depth 113 mm

48 x 48 mm, depth 113 mm

Serial Ports TTL for connection to Copy Card

TTL for connection to Copy Card

TTL for connection to Copy Card + RS-485 connection

Casing plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin

IP Rating IP65 (Front Panel) IP65 (Front Panel) IP65 (Front Panel)

Page 30: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ28

• Controlled Temperature Above or Below Ambient

• Internal Temperature –10 to + 40 ºC

• Internal Temperature Logging (optional)

• Digital Temperature Set Point

• Password Protected Set Point Lock

• High and Low Temperature Alarms

• Operates from 12 / 24 Volts dc or 240 Vac

• Automatic Voltage Switching

The MEDIBOX range of Portable Transporters has been specifically designed to meet the rigorous legislation governing the storage and transportation of Blood and other temperature sensitive products.

Its rugged build quality and high operating specifications mean it can operate in the aggressive environment of vehicles where the ambient temperature can vary widely during a journey and throughout the seasons.

Its efficient compressor refrigeration plant and integral heaters combine to give excellent temperature stability, whilst its internal data logger* provides a detailed record of the product temperature history.

*Optional

MB 80

Vehicle mounting brackets available

Technical Specification

Internal Temperature Range -10 to + 40°C

Ambient Operating Range -20 to + 40°C

Temperature Stability + / - 1.5°C

Chill Down Time Set point 5 OC Ambient 21°C

20 minutes

Power Supply 240 / 110Vac or 12 / 24Vdc Auto Switching

Power Consumption (Max) 65 Watts

Dimensions MB 50 630 x 360 x 480 High (Not Inc Handles)

Dimensions MB 80 790 x 500 x 455 High (Not Inc Handles)

Weight MB 50 / 80 18 / 31 Kg

Capacity MB 50 / 80 49 / 80 litres

- Portable Blood Banks & Pharmaceutical Transporters

MB 50

Page 31: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 29

• Controlled Temperature Above or Below Ambient

• Internal Temperature + 4 to + 40 ºC (+4 at 21 ºC Ambient)

• Internal Temperature Logging (Optional)

• Digital Temperature Set Point

• Password Protected Set Point Lock

• High and Low Temperature Alarms (Optional)

• Operates from 12 / 24 Volts dc or 240 Vac

• Automatic Voltage Switching

The MEDIBOX Lite has been designed to provide a reliable temperature controlled environment for the transportation of temperature sensitive products.

It is light, can easily be carried by hand and operates from either the mains or the Cigar Lighter Socket of a car or van. Its many uses include the transportation of blood samples, cultures and AI (Artificial Insemination) Products.

The MEDIBOX Lite provides a cost effective alternative to the MEDIBOX 50/80 range where the ambient conditions are not as harsh.

Its Peltier cooler and integral heaters combine to give excellent temperature stability.

Technical Specification

Internal Temperature Range Cooling 2°C to 15°C ( 30°C below ambient) Heating 15°C to 40°C

Temperature Stability + / - 1.5°C

Chill Down Time Set point 5°C Ambient 21°C 40 minutes

Power Supply 240 / 110Vac or 12 / 24Vdc Auto Switching

Power Consumption (Max) 60 Watts @ 12 Vdc, 70 watts at 230 volts

Dimensions 450 x 303 x 420 High

Weight 6.0 Kg

Capacity 20 Litres

LITE - Portable Blood Banks & Pharmaceutical Transporters

Page 32: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ30

On Site Temperature Calibration

Abacus can provide a complete on site calibration service to provide cer tification with full U.K.A.S. traceability. This service is available to all food, pharmaceutical and blood storage facilities.

Service to assist Hospital MHRA obligations.

Abacus Instruments offer Temperature Mapping and Calibration services to help with your annual responsibility. Below are some of the regulations as published at www.transfusionguidelines.org.uk

Blood Safety and Quality Regulations 2005The Cold Chain & Calibration of Monitoring / Recording Equipment

• The cold chain for the hospital transfusion laboratory starts from the receipt of the blood from the blood centre to the time the unit is transfused or otherwise disposed of.

• GDP (Good Distribution Practice) requires us to – “ensure that storage conditions are observed at all times, including during transportation”

• Cold storage

o Temperatures should be measured continually

o Continuous 24 hour, 365 day monitoring for temperature alarm conditions

o Defined procedure for responding to alarms, and contingency arrangements for dealing with stock in prolonged alarm situations

o Maximum and minimum recorded daily

o Accuracy of ± 0.5°C

o Consider the location of the equipment

o Red cell components must be stored within the temperature range

• 2 - 6°C core temperature

o Chart recorder, digital readout, max/min thermometer, central monitoring system, BUT whichever you choose will need to be calibrated annually and you will need an in date cer tificate for the calibration equipment, traceable to National Standards.

o Paperwork/electronic storage records kept for 15 years

Page 33: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 31

Temperature Mapping

• All equipment controlling temperature must be temperature mapped once a year.

• The test must have a duration of at least 24 hours and should, for the smallest of storage equipment, include a minimum of 3 points which will normally be at least the centre chamber, top and bottom. The number of probes must be sufficient to comprehensively cover the area being mapped, therefore for equipment such as larger fridges, dual chamber fridges and walk-in cold rooms the number of probes should be increased based on a documented scientific justification. In the case of larger equipment, it is expected that mapping locations will normally be at least the centre chamber, and the 4 corners top and bottom of the parts

of the cabinet used for storage. Mapping exercises should include correlation between the routine probe readings and the mapping probes to demonstrate that any condition shown by the routine probes will be representative of any extremes seen i.e. the routine probes must be demonstrated as being in the hot and cold spots of the bank.

• The cabinet can be used during the test. The amount and type of product in the cabinet during the test must be recorded with the test results.

• The minimum mapping probe calibration tolerance is ± 0.5°C and the frequency of temperature logging to be no longer than 5 minutes.

For any fur ther information on the services we provide then please contact us on

or email [email protected]

01462 638200

Current Requirements

Page 34: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

13a Old Bridge Way, Shefford, Beds SG17 5HQ32

In House UKAS Calibration

Abacus Instruments provide a return to factory calibration service for all temperature chart recorders and portable temperature equipment. This includes all make of thermometers, temperature recorders and data loggers from any manufacturer.

Each UKAS Certificate indicates the deviations from standards at various check points, the standard being -18,0,40,70 and 100°C with a guaranteed uncertainty, dependant on the probe type.

Data Loggers

Each UKAS certificate indicates the deviations from standards at three check points (-18, 0, 40°C) to an uncertainty of +/- 0.04°C

Page 35: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Tel: 01462 638200 Fax: 01462 638201

Email: [email protected] 33

Charts and Consumables

Charts and Consumables

Abacus Instruments also stock a large range of char ts, pens and consumables for all makes of recorders including:-

Abacus InstrumentsJules RichardABB InstrumentationRotothermChessellDicksonHoneywellNegrettiLeeds & NorthrupKentPartlowAnd many more.

Please Phone

to discuss any chart type that you require.

01462 638200

Page 36: Calibration - Abacus Instrumentsabacusinstruments.com/images/Abacus_Brochure_print_Final.pdf · Measurement • Data Logging • Calibration • Control • Alarms Measurement •

Abacus Instruments Ltd13a Old Bridge Way

SheffordBedfordshire

T: 01462 638200F: 01462 638201

[email protected]

ww

w.ab

acusin

strum

en

ts.com