cable tray selection 2

7
C S Cable Tray

Upload: mwp-madushanka

Post on 10-Apr-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 1/7

C SCable Tray

Page 2: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 2/7

Haner BracketHorizontal PivotConnector (w/Run)

Flow ThruCross Tee

Blind End

Field Cross

Field Tee

Wall TrayMountin Bracket

Wall TrayDouble TierWall Tray

 Tray to BoxConnector

Radius RunAdapters

 Tray to Wall Connector

Cable Dropout

Center SpineCable Tray

Double Tier CenterSpine Cable Tray

Vertical PivotConnector

C SCb Tray

Fs andBfs

Center Spine Cable Tray is an easily installed cable support

system designed with many unique eatures to provide saety,

reliability and exibility or uture expansion. Field modifablefttings combine to allow installers to easily maneuver around

unoreseen obstructions and sudden changes in elevation. In order to reduce installation time, each tray

also comes with preassembled couplings. Never beore has hanging cable tray been so easy! Center Spine

Cable Tray can be used to construct a complete FiberReady® cable tray system with controlled 2” [51mm]

nominal bend radius that meets the specifcations or fber optic and UTP/STP cabling and exceeds TIA

569 requirements or communications pathways. Designed or use in retroft, new or existing applications.

Speciy Center Spine Cable Tray and FiberReady fttings, available only rom Cablofl.

• Cable bend radius control ttings. Bend radius adapt er and

cable drop out fttings can be added to any installation to

meet bend radius compliance standards. These parts meet

the specifcations or Fiber Optic and UTP/STP cabling and

exceed TIA569 requirements.

• Preassembled splice connector. A splice connector is

provided to acilitate installation.

• Center lines are provided as drilling guides. All spines and

fttings are designed with center alignment marks to make

adding screw holes easy in the feld.

• Tray, rungs and ttings are available factory painted

in a wide variety o colors. Can be used to enhance

the aesthetics o any installation or allow or visual

dierentiation between cable runs.

• 3" center spine serves as a barrier between services.

The 3" spine serves as a barrier separating one channel of

the tray from the other when used with 3" rungs.

• Center Spine Cable Tray: 

• Installs in half the t ime of conventional ladder tray. 

• Can be loaded from sides of tray in most cases. 

• Uses half the hanging and j oining material of

conventional ladder tray.• Allows for full cable visibility and requires less space for 

access. Can be hung as close to ceiling as code allows.

SpeCMate a SerieS Center Spine CaBle tray SySteM layout with FiBerready FittingS

Cable Drop Out Fitting on 12" CS Sshown to the let, mainta

even under h

CS Series Center Spine Cable Tray providesan excellent solution or overhead wire

and cable management

Page 3: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 3/7

pc Selection Guide: CSdt

pc Selection Guide: CS

* When ordering a tray 18" in width or larger the use of a stiffener bar (CSSB) should be considered to stabilize eccentric loading.* When ordering a tray 18" in width or larger the use of a stiffener bar (CSSB) should be considered to stabilize eccentric loading.

To order one 12’ length of standard Wall Spine Cable Tray, 3” deep Top Tier, 4” deep Second Tier, 12” rungspacing, 12” wide Top Tier, and 24” wide Second Tier with 5/8” rungs, use catalog number:

To order one 12' length of standard Center Spine Cable Tray, 3" deep, 12" rung spacing and 24" wide with 5/8" rungs, use catalog number:

5/8" 16mm

5/8"16mm

5/8" 16mm

5/8"16mm

Run Spacin

Side View (SeCtion)

RunSpacin

Side View (SeCtion)

CS Catalog nuMBering exaMple:

C S – 1 2 – 0 3 – 1 2 – 2 4pc n.

Ss

03 - 3" 76mm04 - 4" 102mm06 - 6" 152mm

10 - 10' 3.0m12 - 12' 3.6m

06 - 6" 152mm09 - 9" 229mm12 - 12" 305mm

06 - 6" 152mm09 - 9" 229mm12 - 12" 305mm18 - 18" 457mm24- 24" 610mm

l t d r Sc ov t w*

note: Measured at inside o rungs as shown above.

CSdt Catalog nuMBering exaMple:

C S d t – 1 2 – 0 3 – 0 4 – 1 2 - 1 2 – 2 4pc n.

Ss

03 - 3" 76mm04 - 4" 102mm06 - 6" 152mm

03 - 3" 76mm04 - 4" 102mm06 - 6" 152mm

10 - 10' 3.0m12 - 12' 3.6m 06 - 6" 152mm

09 - 9" 229mm12 - 12" 305mm

06 - 6" 152mm09 - 9" 229mm12 - 12" 305mm18 - 18" 457mm24- 24" 610mm

06 - 6" 152m09 - 9" 229m12 - 12" 305m18 - 18" 457m24- 24" 610m

lt t d 2 t d r Sc

t t w* 2 t w

note: Measured at inside o rungs as shown above.

1/2 TrayWidth

1/2 TrayWidth

1 1/2"38mm

 TrayDepth

end View

 Top Tier Tray Width

 Top Tier TrDepth

Bottom Tier Tray Width

1 1/2"38mm

Bottom Tier

Depth

end View

Page 4: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 4/7

pc Selection Guide: wSdt

pc Selection Guide: wS

To order one 12' length of standard Wall Spine Cable Tray, 3” deep Top Tier, 4” deep Second Tier, 12" rungspacing, 9" wide Top Tier, and 12” wide Second Tier with 5/8" rungs, use catalog number:

To order one 12' length of standard Wall Spine Cable Tray, 3" deep, 12" rung spacing and 12" wide with  5/8" rungs, use catalog number:

5/8" 16mm

5/8"16mm

5/8" 16mm

5/8"16mm

Run Spacin

Side View (SeCtion)

RunSpacin

Side View (SeCtion)

wS Catalog nuMBering exaMple:

wS – 1 2 – 0 3 – 1 2 – 1 2pc n.

Ss

03 - 3" 76mm04 - 4" 102mm06 - 6" 152mm

10 - 10' 3.0m12 - 12' 3.6m

06 - 6" 152mm09 - 9" 229mm12 - 12" 305mm

03 - 3” 76mm06 - 6” 152mm09 - 9” 229mm12 - 12” 305mm

l t d r Sc ov t w

note: Measured at inside o rungs as shown above.

wSdt Catalog nuMBering exaMple:

w S d t – 1 2 – 0 3 – 0 4 – 1 2 - 0 9 – 1 2pc n.

Ss

03 - 3" 76mm04 - 4" 102mm06 - 6" 152mm

03 - 3" 76mm04 - 4" 102mm06 - 6" 152mm

10 - 10' 3.0m12 - 12' 3.6m 06 - 6" 152mm

09 - 9" 229mm12 - 12" 305mm

03 - 3” 76mm06 - 6” 152mm09 - 9" 229mm12 - 12" 305mm

03 - 3” 76mm06 - 6” 152m09 - 9” 229m12 - 12” 305m

lt t d 2 t d r Sc

t t w 2 t w

note: Measured at inside o rungs as shown above.

1/2 TrayWidth

1 1/2"38mm

 TrayDepth

end View

 Top Tier Tray Width

 Top Tier TraDepth

Bottom Tier Tray Width

1 1/2"38mm

Bottom Tier T

Depth

end View

Page 5: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 5/7

tcc Datal TablesCenter Spine CaBle tray wire Fill CapaCity – 3” [76mm] tall rung

CaBle/wire type

CaBle/wire Size

o.d. nuMBer oF wireS (height x width)

inches mm 3 x6 3 x9 3 x12 3 x18 3 x24

UNSHIELDEDWISTED PAIR

2-pair, 24 AWG4-pair, 24 AWG, Cat 34-pair, 24 AWG, Cat 5e4-pair, 24 AWG, Cat 64-pair, 24 AWG, Cat 6a25-pair, 24 AWG

0.1500.1900.2100.2500.3540.360

3.84.85.36.49.09.0

5083172601839188

763475390275137133

1017634520367183177

1525951

780550274265

20341268

1039733366354

COAXIAL RG6/U 0.270 7.0 157 236 314 471 628

FIBER OPTIC 2-Strand (Zip Cord)Round 4 Strand FiberRound 6 Strand Fiber

0.118x0.2360.1870.256

3 x 64.76.5

323328175

485492262

646655350

970983525

12931311699

Center Spine CaBle tray wire Fill CapaCity – 6” [152mm] tall rung

CaBle/wire type

CaBle/wire Size

o.d. nuMBer oF wireS (height x width)

inches mm 6X6 6X9 6X12 6X18 6X24

UNSHIELDEDWISTED PAIR

2-pair, 24 AWG4-pair, 24 AWG, Cat 3

4-pair, 24 AWG, Cat 5e4-pair, 24 AWG, Cat 64-pair, 24 AWG, Cat 6a25-pair, 24 AWG

0.1500.190

0.2100.2500.3540.360

3.84.8

5.36.49.09.0

10172353

20791467732707

1525951

780550274265

20341268

1039733366354

30511901

15591100549530

40682535

20791467732707

COAXIAL RG6/U 0.270 7.0 1257 471 628 942 1257

FIBER OPTIC 2-Strand (Zip Cord)Round 4 Strand FiberRound 6 Strand Fiber

0.118x0.2360.1870.256

3 x 64.76.5

258526221399

970983525

12931311699

193919661049

258526221399

Center Spine CaBle tray wire Fill CapaCity – 4” [102mm] tall rung

CaBle/wire type

CaBle/wire Size

o.d. nuMBer oF wireS (height x width)

inches mm 4X6 4X9 4X12 4X18 4X19 4X24

UNSHIELDEDWISTED PAIR

2-pair, 24 AWG4-pair, 24 AWG, Cat 34-pair, 24 AWG, Cat 5e4-pair, 24 AWG, Cat 64-pair, 24 AWG, Cat 6a25-pair, 24 AWG

0.1500.1900.2100.2500.3540.360

3.84.85.36.49.09.0

678423346244122118

1017634520367183177

1356845693489244236

20341268

1039733366354

20341268

1039733366354

271216901386978488472

COAXIAL RG6/U 0.270 7.0 209 314 419 628 628 838

FIBER OPTIC 2-Strand (Zip Cord)Round 4 Strand FiberRound 6 Strand Fiber

0.118x0.2360.1870.256

3 x 64.76.5

431437233

646655350

862874466

12931311699

12931311699

17241748933

ote: Values are based on fll capacity only – cable weights must also be checked to ensure that load capacity o the tray is notceeded. Fill values are based on NEC ll requirement stating a maximum allowable ll of 50% of tray cross sectional area.reality, this is a ully loaded tray due to spaces between cables.

neMa load/Span deSignationS

neMa ClaSS Support Span working load*

12A 12 t. 50 lb./ft.

12B 12 t. 75 lb./ft.

12C 12 t. 100 lb./ft.

CSa load ClaSS CapaCitieS at Varying Support SpaCingS

CSa ClaSS

Support SpaCing

1.5m 2.0m 2.5m 3.0m

working load*

a 99kg/m 62kg/m 45kg/m 37kg/m

C1 259kg/m 164kg/m 119kg/m 97kg/m

d1 N/A N/A N/A 179kg/m

e N/A N/A N/A 299kg/m

* The working load is the total weight o all cablesand tubing to be placed in the tray.

When designing, specifying or installing a cable tray system, please consider the following (from the Canadian Electrical Cod

Appendix B 12-2202): 

a. Some ttings (particularly horizontal elbows) may require additional support depending on the loading.

Per NEMA Standard Publication VE-1, Cable Tray is designed as a support or power or control cables, or both, and is not

intended or designed to be a walkway or personnel. The user is urged to display appropriate warnings against the use o th

support as a walkway. Each section o tray has a warning label.

Page 6: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 6/7

C SFs

CSSC Sc Cc – Allows theconnection o any two pieces oCS/WS Series Tray. Hole in centeraccepts 1/2" threaded rod forhanging.

CSgh g r – A single rung, bent in t heshape of a "G". Supports cables onwalls and ceilings.

CShp h pv Cc – Allowsany angle horizontal connection forall CS/WS Series Tray. For 90° orwider angles, the use of a HorizontalPivot Connector with Rung isrecommended.

CSdo () Fb r Cb d –Extruded aluminum ftting providesa 2" cable bend radius for cablesdropping out o all CS/WS Seriestrays.

CShpr* h pv Cc r – Provides additional cablesupport on horizontal connections forall CS/WS Series Tray. Can be usedfor any angle horizontal connection.

CShB h Bc – Provides supportor the tray at any point other than atthe splice connector without drilling.May also be used to develop seismicrestraint – consult actory. Hole ispre-punched to accept 1/2" threadedrod.

CSVp Vc pv Cc – Allows orvertical bends or all CS/WS Seriestrays.

CSeB () () B e – Closes o the end othe tray.

CSra () Fbr 2" rs r a –Slips onto any CS/WS Series rungand provides a 2" radius on eitherside or cable dropout protection ortee or cross transition.

CStB () () t B Cc – Providesa rame or cables entering the trayrom or through a wall.

CStw t w Cc e C –Connects tray to wall.

CSFt () F t – Used to make atee (or "Y" turn) in the eld fortrays with any rung spacing.Speciy tray width.

CSFC () F Css – Used to make across in the fled. For nay rungspacing. Speciy tray width.

CSFS () F S BcProvides support or trused in raised oorapplications. Speciy hfrom oor (to bottom orequired.

CSFlt () F-t Css t – Tee,cross or "Y" turn with nobarrier between channels.

CSSBS B – Provideadditional support to oeccentric loading.

CSCp ( sc) C Cc – Connectsconduit to tray. 1/2", 3/4",1 1/4", and 2" trade sizeknockouts provided.

CSdS3" dv S – Provbarrier for 3" high tray

4" dv S – Provbarrier for 4" high tray

6" dv S – Provbarrier for 6" high tray

All divider strips come12’ sections.

CSJh* J r – A single rung, bentin the shape of a "J". Supportscables on walls.

SpMgl g l – For uwith FieldMate™ orSpecMate™ Cable Traysprovide ground continuElectroplated aluminuDual rated or copper aaluminum conductorsNo. 2 to 14 gage cable

C S J h – 3 – 6 – 8

exaMple: CSJh368

pc n.

produCt nuMBering exaMple*:

SERIES RUNg DEPTH RUNg WIDTH RUNg LENgT

note: See pages 4-5 for standard heights, widths, and rung

       d     e     p      t       h

w

l   en  gt    h  

       d     e     p      t       h

w

l   en  gt    h  

       d     e     p      t       h

w

       l     e     n     g      t       h

r w

4 6 9 12 18 24 in

r d

3 4 6 in

r w

4 6 9 12 in

r d

3 4 6 in

r l

6 8 in

r w

4 6 9 12 in

r d

3 4 6 in

r l6 8 in

Page 7: Cable Tray Selection 2

8/8/2019 Cable Tray Selection 2

http://slidepdf.com/reader/full/cable-tray-selection-2 7/7

.cb.cmPhone 800-658-4641

618-566-3230Fax 618-566-3250

8319 State Route 4Mascoutah, IL 62258 USA

05/09P R O D U C T I V I T Y T H A T W O R K S .

o pcs romCbf/l®

Cablofl/Legrand® is leading the industry with new products and installation methods that help contractors

nish projects faster, while supporting cables better. Review our expanded line of products and see why

many electrical industry proessionals are turning to Cablofl/Legrand as their key to the uture.

Cbf w MsCb tThe world’s standard or

high quality, wire meshcable tray.

pw t r l, t &S Bm SsmsLook to PW cable tray to support heavycable loads and long spans up to 40’.

FaS p p-Fbc w SsmsPre-wired electrical assemblies that

reduce install costs by 50%.