cable glands rev and revd series
DESCRIPTION
Cable Glands REV and REVD SeriesTRANSCRIPT
-
5/19/2018 Cable Glands REV and REVD Series
1/20
1 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
...Your Best Solution
for three methods of protection: Ex d/Ex e/Ex tb
TECHNICAL DATA SHEETNEW PRODUCTRev. 3 05/2014
New Cable Glands REV and REVD series
for ATEX and IECEx world
-
5/19/2018 Cable Glands REV and REVD Series
2/20
2 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
1. The symbol CE means "Conformit Europenne" and it shows that the item is complying the essentialrequirements of the Directives on safety, public health, consumer protection, ecc
2. N of the registered body (CESI) responsible for production monitoring in accordance with Directive94/9/CE ATEX
3. Denotes the equipment with explosion protection
4. Group II (surface devices)5. Category 2 (suitable for zone 1 and 2 for gas and zone 21 and 22 for dust)6. Gas and Dust (this material can be installed both in presence of gas and dust)7. ATEX Certification number8. Protection method (Ex d: flame-proof, Ex e: increased safety, IIC: GAS group, Gb: Epl Equipment
protection level, Ex tb: dusts protection, IIIC: dusts group)9. IP protection10. IECEx Certification number
MARKING REVAND REVDSERIES CABLE GLANDS
ZONES 1 - 21 - 2 - 22
AMBIENT TEMPERATURE -40C +110C
IP PROTECTION IP66/67
ATEX CERTIFICATION CESI 13 ATEX019X (ELFIT)CESI 13 ATEX 032X (CORTEM)
IECEx CERTIFICATION IECEx CES 13.0005X (ELFIT)IECEx CES 13.0011X (CORTEM)
CONFORMITY TO STANDARDS
ATEX 94/9/CEEN 60079-0:2012; EN60079-1:2007;EN 60079-7:2007; EN 60079-31:2009;EN 60529:1991IEC 60079-0:2011; IEC 60079-1:2007;IEC 60079-7:2006; IEC 60079-31:2008;IEC 60529:2001RoHS standard 2002/95/CE
OTHER CERTIFICATIONS Russian certification GOST TR CU
CERTIFICATE DATA AND CONFORMITY TO STANDARDS
PRODUCT DESCRIPTION REVAND REVDCABLE GLANDS
The new cable glands of REV and REVDseries are suitable for use in hazardous areas with danger of e-
xplosion to enable direct insertion of non-armoured cables, REV series cable glands, and of armored ca-
bles, REVD series cable glands, into explosion-proof junction boxes and/or lighting fixtures, plugs and so-ckets,etc...
-
5/19/2018 Cable Glands REV and REVD Series
3/20
3 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
The new cable glands series has optimally exceeded all the tests currently requi-
red for the certification of this product. The result is a cable gland of highest per-
formance in terms of reliability and safety, able to cover a wide range of the main cables on the marked
such as plaited armoured cables, flat or wire cables with armour thickness from 0 to 2,5 mm.
REVand REVDseries is more competitive and, at the same time, more powerful than the cable glands of
the previous series.
The most important innovation is the use of one sealing ring on the inner and outer sheath of the cable
and no longer a kit of sealing rings of different diameters. REVseries is constituted by a single sealing ring
which tightens the incoming cable ensuring the 'Ex d' way of protection. REVDseries has a second sealing
ring that tightens on the outer sheath of the cable to ensure the IP66/67 degree of protection avoiding the
ingress of water, moisture, rain and dust. The cable range available for each cable gland is described in
the following tables.
A further advantage is the lighter weight and the smaller dimensions, an important detail when theres the
need to install a large number of cable glands on explosion-proof enclosures.
The new cable glands REV and REVD series have been designed to replace FL/FG e FAL/FGA series
cable glands. They are realized in NICKEL-PLATED BRASS, STAINLESS STEEL and GALVANIZED
STEELfrom 3/8" up to 2 and in NICKEL-PLATED BRASS andSTAINLESS STEELfrom 2 1/2 up to 4".
This new series includes also REVL, REVDL series special version which can accommodate smaller cable
diameters than the standard required for each measure. In this way, the use of reductions is avoids.
The new cable glands of REVFand REVNseries are designed to replace the FGF series (female threaded
entry) and the FGN series cable glands (male threaded entry) available from 3/8" to 2" sizes and made of
NICKEL-PLATED BRASS, STAINLESS STEEL and GALVANIZED STEEL. Its also available a water-
proof series: TEV series for non-armoured cables and TEVDfor armoured cables.
They are provided with high-tech and high mechanical performance compression rings and gaskets
with high-temperature resistance.
Thanks to their structure, they are particularly suitable both in harsh application, such as marine one, and
places subjected to stress and mechanical shock as often happens in all those places of the heavy in-
dustry where safety is a top priority.
The new series has three types of protection 'Ex d', 'Ex e' and 'Ex tb'. It can be also used in Ex i intrinsic
safety circuits. In this case, the cable glands have a part painted light blue.
The evolution of the marking has allowed us to create a transparent polyester label which has stood very
well the various tests of salt corrosion, durability in harsh environments and high temperatures, impact resi-
stance.
In order to ensure a greater security and reliability of its cable glands, Elfit, in addition to mandatory certifi-
cation tests, submits its products to further harsher tests. It evaluates the resistance of its cable glands to a
traction test without fixing the cable armour and with much higher load values (up
to an extra 50%) than required by the standard.
-
5/19/2018 Cable Glands REV and REVD Series
4/20
4 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
DETAILS OF REV SERIES CABLE GLANDSFOR UNARMOURED CABLES FROM 3/8 TO2
CABLE GLAND PARTS
1. Body2. Sealing ring3. Compression ring in plastic material4. Nut
1
23
4
ASSEMBLING INSTRUCTIONS
Step 1 Insert on the cable the nut 4and the compression ring 3
Step 2 Assembly the body 1 and the sealing ring 2 with the equipment
Step 3 After inserting the cable into the sealing ring 2 close by tightening the nut 4
Cable gland properlyassembled
-
5/19/2018 Cable Glands REV and REVD Series
5/20
5 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONSREV SERIES CABLE GLANDS FOR UNARMOURED CABLES FROM3/8 TO2
Code
REV
Nickel-platedbrass
Code
REV
StainlessSteel
Code
REV
GalvanizedSteel
Dimensions mm Cable Range mm
AC M C d min-max
REV01B REV01S REV01G 3/8" ISO7/1 24 28 44 5 10
REV1B REV1S REV1G 1/2" ISO7/1 24 28 47 7 12
REV2B REV2S REV2G 3/4" ISO7/1 32 37 48,5 12 18
REV3B REV3S REV3G 1" ISO7/1 40 47 59,5 18 24
REV4B REV4S REV4G 1 1/4 ISO7/1 48 56 60 24 30
REV5B REV5S REV5G 1 1/2 ISO7/1 53 62 64 30 35
REV6B REV6S REV6G 2" ISO7/1 63 73 64 35 45REV01NB REV01NS REV01NG 3/8" NPT 24 28 45 5 10
REV1NB REV1NS REV1NG 1/2" NPT 24 28 49 7 12
REV2NB REV2NS REV2NG 3/4" NPT 32 37 50,5 12 18
REV3NB REV3NS REV3NG 1" NPT 40 47 63,5 18 24
REV4NB REV4NS REV4NG 1 1/4 NPT 48 56 64 24 30
REV5NB REV5NS REV5NG 1 1/2 NPT 53 62 66 30 35
REV6NB REV6NS REV6NG 2" NPT 63 73 67 35 45
REV01IB REV01IS REV01IG *M16X1,5 24 28 45 5 10
REV1IB REV1IS REV1IG *M20X1,5 24 28 45 7 12
REV2IB REV2IS REV2IG *M25X1,5 32 37 46,5 12 18
REV3IB REV3IS REV3IG *M32X1,5 40 47 53,5 18 24REV4IB REV4IS REV4IG *M40X1,5 48 56 54 24 30
REV5IB REV5IS REV5IG *M50X1,5 53 62 56 30 35
REV6IB REV6IS REV6IG *M63X1,5 63/65 73 58 35 45
Thread*
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
-
5/19/2018 Cable Glands REV and REVD Series
6/20
6 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONS REVL CABLE GLANDSSPECIAL VERSION FOR UNARMOURED CABLES FROM1/2 TO2
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
Code
REVL
Nickel-platedbrass
Code
REVL
StainlessSteel
Code
REVL
GalvanizedSteel
Dimensions mm Cable Range mm
AC1 AC2 M1
C d min-max
REVL1B REVL1S REVL1G 1/2" ISO7/1
24
24
28
47 5 10
REVL2B REVL2S REVL2G 3/4" ISO7/1 32 24 37 47 7 12
REVL3B REVL3S REVL3G 1" ISO7/1 40 32 47 52,5 12 18
REVL4B REVL4S REVL4G 1 1/4 ISO7/1
48
40
56
59,5 18 24
REVL5B REVL5S REVL5G 1 1/2 ISO7/1 53 48 62 62 24 30
REVL6B
REVL6S
REVL6G
2" ISO7/1
63
53
73
64 30 35
REVL1NB
REVL1NS
REVL1NG
1/2 NPT
24
24
28
49 5 10
REVL2NB REVL2NS REVL2NG 3/4 NPT 32 24 37 49 7 12
REVL3NB
REVL3NS
REVL3NG 1 NPT 40 32 47 56,5 12 18
REVL4NB REVL4NS REVL4NG 1 1/4 NPT
48
40
56
63,5 18 24
REVL5NB REVL5NS REVL5NG 1 1/2 NPT
53
48
62
64 24 30
REVL6NB REVL6NS REVL6NG 2 NPT 63 53 73 67 30 35
REVL1IB REVL1IS REVL1IG *M20X1,5 24 24 28 45 5 10
REVL2IB
REVL2IS
REVL2IG *M25X1,5 32 24 37 45 7 12
REVL3IB REVL3IS REVL3IG *M32X1,5 40
32
47
46,5 12 18
REVL4IB REVL4IS REVL4IG *M40X1,5 48 40 56 53,5 18 24
REVL5IB
REVL5IS
REVL5IG *M50X1,5 53 48 62 54 24 30
REVL6IB
REVL6IS
REVL6IG
*M63X1,5
63/65
53
73
58 30 35
Thread*
-
5/19/2018 Cable Glands REV and REVD Series
7/20
7 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONS REVF CABLE GLANDS VERSIONFOR UNARMOURED CABLES FROM3/8 TO 2 WITH A FEMALETHREADED ENTRY
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
CodeREVF(female)
Nickel-plated brass
CodeREVF(female)
StainlessSteel
CodeREVF(female)
GalvanizedSteel
Dimensions mm Cable Range mm
AC M C d min-max
REVF01B REVF01S REVF01G 3/8" ISO7/1 24 28 69,5 5 10
REVF1B REVF1S REVF1G 1/2" ISO7/1 24 28 75,5 7 12
REVF2B REVF2S REVF2G 3/4" ISO7/1 32 37 77 12 18
REVF3B REVF3S REVF3G 1" ISO7/1 40 47 92 18 24
REVF4B REVF4S REVF4G 1 1/4 ISO7/1 48 56 92,5 24 30
REVF5B REVF5S REVF5G 1 1/2 ISO7/1 53 62 98,5 30 35REVF6B REVF6S REVF6G 2" ISO7/1 63 73 98,5 35 45
REVF01NB REVF01NS REVF01NG 3/8" NPT 24 28 68,5 5 10
REVF1NB REVF1NS REVF1NG 1/2" NPT 24 28 76,5 7 12
REVF2NB REVF2NS REVF2NG 3/4" NPT 32 37 78 12 18
REVF3NB REVF3NS REVF3NG 1" NPT 40 47 94 18 24
REVF4NB REVF4NS REVF4NG 1 1/4 NPT 48 56 95,5 24 30
REVF5NB REVF5NS REVF5NG 1 1/2 NPT 53 62 97,5 30 35
REVF6NB REVF6NS REVF6NG 2" NPT 63 73 98,5 35 45
REVF01IB REVF01IS REVF01IG *M16X1,5 24 28 70,5 5 10
REVF1IB REVF1IS REVF1IG *M20X1,5 24 28 70,5 7 12
REVF2IB REVF2IS REVF2IG *M25X1,5 32 37 72 12 18
REVF3IB REVF3IS REVF3IG *M32X1,5 40 47 79 18 24
REVF4IB REVF4IS REVF4IG *M40X1,5 48 56 79,5 24 30
REVF5IB REVF5IS REVF5IG *M50X1,5 53 62 82,5 30 35
REVF6IB REVF6IS REVF6IG *M63X1,5 63/65 73 84,5 35 45
Thread*
-
5/19/2018 Cable Glands REV and REVD Series
8/20
8 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONS REVN CABLE GLANDS VERSIONFOR ARMOURED CABLES FROM3/8 TO2WITH A MALETHREADED ENTRY
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
CodeREVN(male)
Nickel-platedbrass
CodeREVN(male)
StainlessSteel
CodeREVN(male)
GalvanizedSteel
Dimensions mm Cable Range mm
AC M C d min-max
REVN01B REVN01S REVN01G 3/8" ISO7/1 24 28 69,5 5 10
REVN1B REVN1S REVN1G 1/2" ISO7/1 24 28 75,5 7 12
REVN2B REVN2S REVN2G 3/4" ISO7/1 32 37 77 12 18
REVN3B REVN3S REVN3G 1" ISO7/1 40 47 92 18 24
REVN4B REVN4S REVN4G 1 1/4 ISO7/1 48 56 92,5 24 30
REVN5B REVN5S REVN5G 1 1/2 ISO7/1 53 62 98,5 30 35REVN6B REVN6S REVN6G 2" ISO7/1 63 73 98,5 35 45
REVN01NB REVN01NS REVN01NG 3/8" NPT 24 28 71,5 5 10
REVN1NB REVN1NS REVN1NG 1/2" NPT 24 28 79,5 7 12
REVN2NB REVN2NS REVN2NG 3/4" NPT 32 37 81 12 18
REVN3NB REVN3NS REVN3NG 1" NPT 40 47 100 18 24
REVN4NB REVN4NS REVN4NG 1 1/4 NPT 48 56 100,5 24 30
REVN5NB REVN5NS REVN5NG 1 1/2 NPT 53 62 102,5 30 35
REVN6NB REVN6NS REVN6NG 2" NPT 63 73 104,5 35 45
REVN01IB REVN01IS REVN01IG *M16X1,5 24 28 72,5 5 10
REVN1IB REVN1IS REVN1IG *M20X1,5 24 28 66,5 7 12
REVN2IB REVN2IS REVN2IG *M25X1,5 32 37 74 12 18
REVN3IB REVN3IS REVN3IG *M32X1,5 40 47 82 18 24
REVN4IB REVN4IS REVN4IG *M40X1,5 48 56 75,5 24 30
REVN5IB REVN5IS REVN5IG *M50X1,5 53 62 77,5 30 35
REVN6IB REVN6IS REVN6IG *M63X1,5 63/65 73 81,5 35 45
Thread*
-
5/19/2018 Cable Glands REV and REVD Series
9/20
9 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
DETAILS OF REV/REVS SERIES CABLE GLANDSFOR UNARMOURED CABLES FROM2 1/2 TO4
CABLE GLAND PARTS
1. Body2. Compression gasket3. Anti-friction ring4. Nut
ASSEMBLING INSTRUCTIONS
Step 1 Insert on the cable the nut 4and the ring 3
Step 2 Assembly the body 1 and the compression gasket 2 on the electrical equipment
Step 3 After having slipped the cable into the compression gasket 2 close by tightening the nut 4
Cable gland properly assembled
-
5/19/2018 Cable Glands REV and REVD Series
10/20
10 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONSREV/REVS SERIES CABLE GLANDS FOR UNARMOURED CABLES FROM2 1/2 TO4
Code
REV/REVS
Nickel-platedbrass
Code
REV/REVS
StainlessSteel
Thread* Dimensions mm Cable Range mm
AC1 d min-max
REV7B REV7S 2 1/2 ISO7/1 84 73 100 46 55
REVS7B REVS7S 2 1/2 ISO7/1 90 84 100 55 62
REV8B REV8S 3" ISO7/1 100 94 100 62 70
REVS8B REVS8S 3" ISO7/1 105 98 100 70 78
REV9B REV9S 3 1/2 ISO7/1 115 105 101 76 84REVS9B REVS9S 3 1/2 ISO7/1 120 112 101 84 92REV10B REV10S 4" ISO7/1 115 105 101,5 76 84
REVS10B REVS10S 4 ISO7/1 120 112 101,5 84 92
REV7NB REV7NS 2 1/2 NPT 84 73 110 46 55
REVS7NB REVS7NS 2 1/2 NPT 90 84 110 55 62
REV8NB REV8NS 3" NPT 100 94 112 62 70
REVS8NB REVS8NS 3" NPT 105 98 112 70 78
REV9NB REV9NS 3 1/2 NPT 115 105 114 76 84
REVS9NB REVS9NS 3 1/2 NPT 120 112 114 84 92
REV10NB REV10NS 4" NPT 115 105 115,5 76 84
REVS10NB REVS10NS 4 NPT 120 112 115,5 84 92
REV7IB REV7IS *M75X1,5 84 73 88 46 55
REVS7IB REVS7IS *M75X1,5 90 84 88 55 62
REV8IB REV8IS *M90X1,5 100 94 88 62 70REVS8IB REVS8IS *M90X1,5 105 98 88 70 78
REV10IB REV10IS *M100X1,5 115 105 89,5 76 84
REVS10IB REVS10IS *M100X1,5 120 112 89,5 84 92
AC2 C
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
-
5/19/2018 Cable Glands REV and REVD Series
11/20
11 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
DETAILS OF REVD SERIES CABLE GLANDSFOR ARMOURED CABLES FROM3/8 TO2
CABLE GLAND PARTS
1. Body2. Sealing ring3. Conical metallic compression
ring4. Metallic compression ring5. Intermediate Body6. IP sealing ring on the outer
sheath of the cable7. Teflon washer8. Nut
ASSEMBLING INSTRUCTIONS
Step 1 Assembly the body 1complete with the sealing ring 2on the equipment.
Step 2 Insert on the cable in sequence the details 8-7-6-5 and pre-assemble the wholeloosely.
Step 3 Insert the compression ring 4on the cable armour.
Step 4 Open the armour to connect the compression ring 3 withthe compression ring 4.
Step 5 Once connected, no sticking out filaments of the armour should remain becausethey could interfere with the thread of the body 1. If you experience this problem,the filaments must be cut to avoid to compromise the final assembly between thebody 1 and the intermediate body 5.
Step 6 Insert the internal sheath into the sealing ring 2 and the two compression ringspreviously assembled into the body 1, pulling the cable towards the interior of theequipment, so that the armour does not spill out by the two compression rings 3-4.
Step 7 Complete the assembly by tightening the pre-assembled parts (Step 2) on thebody 1 and close the whole system.
1
234
5
6
7
8
Cable gland properly assembled
-
5/19/2018 Cable Glands REV and REVD Series
12/20
12 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONSREVD SERIES CABLE GLANDS FOR ARMOURED CABLES FROM 3/8 TO2
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
Code
REVD
Nickel-plated brass
Code
REVD
StainlessSteel
Code
REVD
GalvanizedSteel
Thread* Cable Range mm
d min-max D min-max
AC M C
Internalsheath
Outersheath of the
cableREVD01B REVD01S REVD01G 3/8" ISO7/1 24 28 69 5 10 8 15
REVD1B REVD1S REVD1G 1/2" ISO7/1 24 28 72 7 12 11 16
REVD2B REVD2S REVD2G 3/4" ISO7/1 32 37 73,5 12 18 16 24
REVD3B REVD3S REVD3G 1" ISO7/1 40 47 86,5 18 24 24 31
REVD4B REVD4S REVD4G 1 1/4 ISO7/1 48 56 89 24 30 31 37
REVD5B REVD5S REVD5G 1 1/2 ISO7/1 53 62 94 30 35 37 43
REVD6B REVD6S REVD6G 2" ISO7/1 63 73 94 35 45 43 53REVD01NB REVD01NS REVD01NG 3/8" NPT 24 28 70 5 10 8 15
REVD1NB REVD1NS REVD1NG 1/2" NPT 24 28 74 7 12 11 16
REVD2NB REVD2NS REVD2NG 3/4" NPT 32 37 75,5 12 18 16 24
REVD3NB REVD3NS REVD3NG 1" NPT 40 47 90,5 18 24 24 31REVD4NB REVD4NS REVD4NG 1 1/4 NPT 48 56 93 24 30 31 37
REVD5NB REVD5NS REVD5NG 1 1/2 NPT 53 62 96 30 35 37 43
REVD6NB REVD6NS REVD6NG 2" NPT 63 73 97 35 45 43 53
REVD01IB REVD01IS REVD01IG *M16X1,5 24 28 70 5 10 8 15
REVD1IB REVD1IS REVD1IG *M20X1,5 24 28 70 7 12 11 16
REVD2IB REVD2IS REVD2IG *M25X1,5 32 37 71,5 12 18 16 24
REVD3IB REVD3IS REVD3IG *M32X1,5 40 47 80,5 18 24 24 31
REVD4IB REVD4IS REVD4IG *M40X1,5 48 56 83 24 30 31 37
REVD5IB REVD5IS REVD5IG *M50X1,5 53 62 86 30 35 37 43
REVD6IB REVD6IS REVD6IG *M63X1,5 63/65 73 88 35 45 43 53
Dimensions mm
-
5/19/2018 Cable Glands REV and REVD Series
13/20
13 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONS REVDL CABLE GLANDSSPECIAL VERSION FOR ARMOURED CABLES FROM1/2 TO2
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
Code
REVDL
Nickel-platedbrass
Code
REVDL
StainlessSteel
Code
REVDL
GalvanizedSteel
Dimensions mm Cable Range mm
d min-max D min-max
AC1 AC2
M1 C
Internalsheath
Outersheath ofthe cable
REVDL1B
REVDL1S
REVDL1G 1/2" ISO7/1
24
24
28 72 5 10 8 15
REVDL2B
REVDL2S
REVDL2G 3/4" ISO7/1
32
24
37 72 7 12 11 16
REVDL3B REVDL3S REVDL3G 1" ISO7/1 40 32 47 77,5 12 18 16 24
REVDL4B
REVDL4S
REVDL4G 1 1/4 ISO7/1
48
40
56 86,5 18 24 24 31
REVDL5B
REVDL5S
REVDL5G 1 1/2 ISO7/1
53
48
62
9124 30
31 37
REVDL6B
REVDL6S
REVDL6G
2" ISO7/1
63
53
73
94 30 35
37 43
REVDL1NB REVDL1NS REVDL1NG 1/2" NPT 24 24 28 74 5 10 8 15REVDL2NB
REVDL2NS
REVDL2NG 3/4" NPT
32
24
37 74 7 12 11 16
REVDL3NB REVDL3NS REVDL3NG 1" NPT 40 32 47 81,5 12 18 16 24
REVDL4NB
REVDL4NS
REVDL4NG 1 1/4 NPT 48 40 56 90,5 18 24 24 31
REVDL5NB
REVDL5NS
REVDL5NG 1 1/2 NPT
53
48
62 93 24 30 31 37
REVDL6NB REVDL6NS REVDL6NG 2" NPT
63
53
73 97 30 35 37 43
REVDL1IB
REVDL1IS
REVDL1IG *M20X1,5
24
24
28 70 5 10 8 15
REVDL2IB
REVDL2IS
REVDL2IG *M25X1,5
32
24
37 70 7 12 11 16
REVDL3IB REVDL3IS REVDL3IG *M32X1,5 40 32 47 71,5 12 18 16 24
REVDL4IB
REVDL4IS
REVDL4IG *M40X1,5
48
40
56 80,5 18 24 24 31
REVDL5IB
REVDL5IS
REVDL5IG *M50X1,5
53
48
62 83 24 30 31 37
REVDL6IB REVDL6IS REVDL6IG *M63X1,5
63/65
53
73 88 30 35 37 43
Thread*
-
5/19/2018 Cable Glands REV and REVD Series
14/20
14 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
DETAILS OF REVD/REVDS SERIES CABLE GLANDSFOR ARMOURED CABLES FROM 2 1/2 TO4
CABLE GLAND PARTS
1. Body2. Compression gasket3. Anti-friction ring4. Armour clamping body5. Ring nut6. Intermediate body7. IP gasket on the outer sheath of
the cable8. Nut
NOTE: REVDS series cable glandshas a special body (1) to accomo-date a wider cable range
ASSEMBLING INSTRUCTIONS
Step 1 Insert on the cable in sequence the details 8-7-6-5-4 and pre-assemble the whole loosely.
Step 2 Fit the body 1complete with the compression gasket 2 and the anti-friction ring 3 on the equipment.
Step 3 After having slipped the under armour sheath of the cable into compression gasket 2, tighten theassembly with the armour clamping body 4. Keep the cable pushed towards the inside of the equi-pment, so that the armour is always in contact with the conical part of the armour tightening section.
Step 4 Push the ring nut 5on the armour and to the cone (armour clamping body 4). The over armour she-ath of the cable must have a maximum distance equal to 2mm from the ring nut 5. Once connected,no sticking out filaments of the armour should remain because they could interfere with the thread. Ifyou experience this problem, the filaments must be cut to avoid to compromise the final assemblybetween the armour clamping body 4 and the intermediate body 6.
Step 5 Assemble the intermediate body 6 with the armour clamping body 4and the ring nut 5, while alwayskeeping the cable pusched towards the inside of the apparatus and ensuring that the armour doesnot move away from the locking system.
Step 6 Complete the installation by tightening the upper gasket 7, which was previously inserted into theintermediate body 6and locked with nut 8.
Cable gland properly assembled
-
5/19/2018 Cable Glands REV and REVD Series
15/20
15 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
MODELS, FEATURES AND DIMENSIONSREVD/REVDS SERIES CABLE GLANDS FOR ARMOURED CABLES FROM 2 1/2 TO4
* The o-ring for IP protection is provided assembled to the cable gland for parallel threads (ISO metric)
Code
REVD/REVDS
Nickel-platedBrass
Code
REVD/REVDS
StainlessSteel
Thread* Cable Range mm
d min-max D min-max
AC1 AC2 AC3 AC4Internalsheath
Outersheath of the
cableREVD7B REVD7S 2 1/2 ISO7/1 84 105 118 127 185 46 55 54 78
REVDS7B REVDS7S 2 1/2 ISO7/1 90 105 118 127 185 55 62 54 78
REVD8B REVD8S 3" ISO7/1 100 113 130 140 185 62 70 64 90
REVDS8B REVDS8S 3" ISO7/1 105 113 130 140 185 70 78 64 90
REVD9B REVD9S 3 1/2 ISO7/1 115 135 144 153 187 76 84 88 104
REVDS9B REVDS9S 3 1/2 ISO7/1 120 135 144 153 187 84 92 88 104REVD10B REVD10S 4" ISO7/1 115 135 144 153 187,5 76 84 88 104
REVDS10B REVDS10S 4 ISO7/1 120 135 144 153 187,5 84 92 88 104
REVD7NB REVD7NS 2 1/2 NPT 84 105 118 127 195 46 55 54 78
REVDS7NB REVDS7NS 2 1/2 NPT 90 105 118 127 195 55 62 54 78
REVD8NB REVD8NS 3" NPT NPT 100 113 130 140 197 62 70 64 90
REVDS8NB REVDS8NS 3" NPT 105 113 130 140 197 70 78 64 90
REVD9NB REVD9NS 3 1/2 NPT 115 135 144 153 200 76 84 88 104
REVDS9NB REVDS9NS 3 1/2 NPT 120 135 144 153 200 84 92 88 104
REVD10NB REVD10NS 4" NPT 115 135 144 153 201,5 76 84 88 104
REVDS10NB REVDS10NS 4 NPT 120 135 144 153 201,5 84 92 88 104
REVD7IB REVD7IS *M75X1,5 84 105 118 127 173 46 55 54 78REVDS7IB REVDS7IS *M75X1,5 90 105 118 127 173 55 62 54 78REVD8IB REVD8IS *M90X1,5 100 113 130 140 173 62 70 64 90
REVDS8IB REVDS8IS *M90X1,5 105 113 130 140 173 70 78 64 90
REVD10IB REVD10IS *M100X1,5 115 135 144 153 175,5 76 84 88 104
REVDS10IB REVDS10IS *M100X1,5 120 135 144 153 175,5 84 92 88 104
Dimensions mm
C
-
5/19/2018 Cable Glands REV and REVD Series
16/20
16 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
TIGHTENING TORQUES TO ENSURE THE CLAMPING OF THE CABLE
Size
Tightening (Nm)
01 20
1 20
2 45
3 50
4 60
5 65
6 65
7 70
8 80
9 90
10 90
STANDARD ACCESSORIES UPON REQUEST
Reducers and adaptorsRE series
They allow the connectionbetween different threads ordifferent sizes.
Plugs PLG... series
They can be used to tem-porarly close not neces-sary entries.
Lock nutsDL series
They assure the fixing ofcable glands with parallelthread (isometric).
Earthing ringsA series
They are used to guaranteethe earthing of the cablegland and the installed e-quipment.
PVC protectorsPGA... series
PGA series protectors aremade in PVC and are usedto offer a further protectionto the cable glands fromthe entry of dusts and li-quids.
Auto-binder tape
Tape for the mechanicalprotection adaptable to allsizes of the cable glands.
Serrated internal washer
Serrated or shake-proof washers act as an anti-vibration device toprevent the cable gland from loosening. It can be also used as anearth enhancing devise on painted enclosures.
-
5/19/2018 Cable Glands REV and REVD Series
17/20
17 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
TABLE OF ACCESSORIES UPON REQUEST
MORE ACCESSORIES UPON REQUEST
CABLEGLANDS
SERIES
CABLE GLAND CODEACCESSORIES
CODE
ACCESSORIES
CODE
ACCESSORIES
CODEPROTECTORS BLACK PVC
01 REV REVD REVL REVDL 01 PGA1F
1 REV REVD REVL REVDL 1 PGA1F
2 REV REVD 2 PGA2R
L2 REVL REVDL 2 PGA1F
3 REV REVD 3 PGA3
L3 REVL REVDL 3 PGA2R
4 REV REVD 4 PGA4
L4 REVL REVDL 4 PGA3
5 REV REVD 5 PGA5
L5 REVL REVDL 5 PGA46 REV REVD 6 PGA6R
L6 REVL REVDL 6 PGA5
LOCK NUTS FOR METRIC CABLE GLANDS
Nickel-plated
brass Galvanized Steel Stainless steel
01 REV REVD REVL REVDL REVF REVN 01I DL01IB DL01IG DL01IS
1 REV REVD REVL REVDL REVF REVN 1I DL1IB DL1IG DL1IS
2 REV REVD REVL REVDL REVF REVN 2I DL2IB DL2IG DL2IS
3 REV REVD REVL REVDL REVF REVN 3I DL3IB DL3IG DL3IS
4 REV REVD REVL REVDL REVF REVN 4I DL4IB DL4IG DL4IS
5 REV REVD REVL REVDL REVF REVN 5I DL5IB DL5IG DL5IS
6 REV REVD REVL REVDL REVF REVN 6I DL6IB DL6IG DL6IS
EARTHING RINGS Thread ISO 261
Nickel-plated
brass Stainless steel
01 REV REVD REVL REVDL REVF REVN 01I A0131B A0131S
1 REV REVD REVL REVDL REVF REVN 1I A1311IB A1311IS
2 REV REVD REVL REVDL REVF REVN 2I A2312IB A2312IS
3 REV REVD REVL REVDL REVF REVN 3I A3313IB A3313IS
4 REV REVD REVL REVDL REVF REVN 4I A4314IB A4314IS
5 REV REVD REVL REVDL REVF REVN 5I A5315IB A5315IS
6 REV REVD REVL REVDL REVF REVN 6I A6316IB A6316IS
SERRATED INTERNAL WASHER Thread ISO 261 Stainless steel
01 REV REVD REVL REVDL REVF REVN 01I RDI01IS/A4
1 REV REVD REVL REVDL REVF REVN 1I RDI1IS/A4
2 REV REVD REVL REVDL REVF REVN 2I RDI2IS/A4
3 REV REVD REVL REVDL REVF REVN 3I RDI3IS/A4
4 REV REVD REVL REVDL REVF REVN 4I RDI4IS/A4
5 REV REVD REVL REVDL REVF REVN 5I RDI5IS/A4
6 REV REVD REVL REVDL REVF REVN 6I RDI6IS/A4
-
5/19/2018 Cable Glands REV and REVD Series
18/20
18 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
APPLICATION EXAMPLES
Cortem aluminium junction box EJB-4 series complete with:
Lighting fixtures FLFE-258 complete with:
n2 REV5NB n 1 REVD6NB
n. 4 PLG2NB
n 7 REVD2NB
n2 REV2IB
Sealant for threads
The Loctite 577 (or a product of equal orsuperior characteristics) must be used onthe threaded entry of NPT and ISO 7/1 ca-ble gland to ensure a better IP seal. Itshould be applied, covering at least 2 fullthreads, only on the tapered thread.
OTHER ACCESSORIES RECOMMENDED
-
5/19/2018 Cable Glands REV and REVD Series
19/20
19 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
APPLICATION
Manufacturing plants and process facilities:chemical, petrochemical, refineries, pharma-ceutical, Gas treatment and transport
Areas with risk of explosion and fire due to
abnormal, unusual or accidental presence ofignitable concentration of gases/vapours anddusts, even simultaneously
On-shore, off-shore, naval and harbour instal-lations
Waste and or sewage treatment facilities
Thermal plants
Area with presence of combustible dusts suchas joineries, sugarhouses, food industries withtreatment and storage of wheat and deriva-tives
Painting plants
MARKET
Industry Mechanical and electrical engineering
Agribusiness
Distillery
Oil & Gas industries Pharmaceutical industries
Energy
Engineering and Contractors Project Design companies
Electrical contractors
Construction companies
Electrical equipment distributors Shipyards / harbours
Off-shore rig constructors
On-shore treatment and refining plants
ATEX REFERENCE STANDARDS
EN 60079-0:2012 Electrical apparatus for explosive gas atmospheresPart 0: General Requiremets
EN60079-1:2007 Electrical apparatus for explosive gas atmospheresPart 1: Flameproof enclosures d
EN 60079-7:2007 Electrical apparatus for explosive gas atmospheresPart 7: Incresed safety e
EN 60079-31:2009 Explosive atmospheresPart 31: Equipment dust ignition protection by enclosure "t"
EN 60529:1991 Degrees of protection provided by enclosures (IP Code)
ATEX 94/9/CE Equipment for explosive atmospheres
IEC 60079-0:2011 Electrical apparatus for explosive gas atmospheresPart 0: General Requiremets
IEC 60079-1:2007 Electrical apparatus for explosive gas atmospheresPart 1: Flameproof enclosures d
IEC 60079-7:2006 Electrical apparatus for explosive gas atmospheresPart 7: Incresed safety e
IEC 60079-31:2008
Explosive atmospheres
Part 31: Equipment dust ignition protection by enclosure "t"
IEC 60529:2001 Degrees of protection provided by enclosures (IP Code)
IECEX REFERENCE STANDARDS
-
5/19/2018 Cable Glands REV and REVD Series
20/20
20 - New Product Technical Data Sheet - REV, REVD series cable glands Rev. 3 - 05/2014
ELFIT S.P.A.
HEADQUARTERS AND FACTORYVia Aquileia 12, 34070 Villesse (GO), ITALY
Tel +39 0481 964911
Fax +39 0481 964999
www.cortemgroup.com
CORTEM S.P.A.
HEADQUARTERS AND FACTORYVia Aquileia 10, 34070 Villesse (GO), ITALY
Tel +39 0481 964911
Fax +39 0481 964999
SALES OFFICESP.le Dateo 2, 20129 Milano ITALIA
Tel +39 02 761100501
Fax +39 02 70005471
www.cortemgroup.com