c400 d6
DESCRIPTION
Grupo Gerador 500KVA CumminsTRANSCRIPT
-
C400 D660Diesel
Our energy working for you.
1/4 1/2 3/4 Full 1/4 1/2 3/4 Full7.9 13.2 18.5 24.2 8.8 12.6 17.1 21.8
36 60 84 110 40 58 78 99
Standby rating
Combustion air, m3/min
PrimeKw (kVA)365 (456.3)
StandbyKw (kVA)400 (500)
2147
406
14:1
152
1800
Overspeed limit, rpm
Regenerative power, kW
Cummins
Prime rating
140
NTA855 G5
4 Cycle; In-line; 6 Cylinder Diesel
Turbocharged and Aftercooled
1911
451
Configuration
BMEP at set rated load, kPa
Aspiration
Bore, mm
Gross engine power output, kWm
Governor type
Starting voltage
Maximum fuel inlet temperature (C)
Maximum fuel inlet restriction, mm Hg
Maximum air cleaner restriction, kPa
213
Engine manufacturer
Engine model
Piston speed, m/s
Compression ratio
Fuel consumption
9.1
Ratings
Stroke, mm
Rated speed, rpm
Load
US gph
L/hr
Engine
37.7Air
Fuel flow
70
203
34.1
Electronic
24 Volts DC
2100 50
22
Lube oil capacity, L
Maximum fuel flow, L/hr
34
2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
6.2
Model:Frequency:Fuel Type:
500 kVA Standby Generator set data sheet
Transient data sheet: TD50-550DD50-OS550 / DD50-CS550
Spec sheet:Noise data sheet (Open/enclosed):Airflow data sheet:Derate data sheet (Open/enclosed):
SS9-CPGKND50-OS550 / ND50-CS550AF50-550
-
Standby
Prime
Open Enclosed
Dimensions
Enclosed set
10.2
Genset outline
107.1Exhaust gas flow at set rated load, m3/min
Fan load, KWm
Coolant capacity (with radiator), L
Cooling system air flow, m3/min @ 12.7mmH2O
19
Exhaust
50
425.5 (340.4)
45C
Maximum exhaust back pressure, kPa
19.1
468.1 (374.5)480.1 (384.1)
508Exhaust gas temperature, C
40C
Ambient design, C
Standard set-mounted radiator cooling
Maximum cooling air flow static restriction mmH2O
27C
Note: Standard open genset options running at 400V, 150m above sea level. For enclosed product derates, please refer to datasheet - DD50-CS550.
5110
5041
Width
* Weights represent a set with standard features. See outline drawing for weights of other configurations
Unit wet weight kgsUnit dry weight kgs
535
HeightLength
3493
500 (400) 492.1 (393.7)
15125
Open set derating factors kVA (kW)
500 (400)
Total heat rejection, BTU/min
50C 55C
Prime rating
13613
99
45
7.2
Standby rating
454.5 (363.6)
5818
Weights*
436.5 (349.2)447.4 (357.9)454.5 (363.6)
3683
Open set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Enclosed set standard dimensions
Standard open set dimensions 21151100
1563 2447
3549
-
Feature codeB252
Formulas for calculating full load currents:
Single phase outputThree phase output
Alternator data
Web: www.cumminspower.comE-Mail: [email protected]: +44 (0) 1843 255902Telephone: +44 (0) 1843 255000
Manston Park, Columbus AvenueManston, Ramsgate
See your distributor for more information.
Kent CT12 5BF, UK
Cummins Power Generation
2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Duty2
Ratings definitions
VoltageAlternator
Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
Emergency Standby Power (ESP) Limited-Time running Power Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528.
Base Load (Continuous) Power Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514.
Prime Power (PRP):Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
HC5C
Temp rise degrees C
416-480VS/P
Connection1
125/105Wye, 3 Phase
73x0.8Voltagex1.kWx1000
Voltagex1000haseFactorkWxSingleP