c shape rc wall design aci-318
DESCRIPTION
RC Wall Design as per ACI-318TRANSCRIPT
-
Concrete Section S-CONCRETE Version 11.00.32 Job #A123.45 Copyright 1995-2013 by S-FRAME Software Inc.
S-CONCRETE 11.00.32 (c) S-FRAME Software Inc.
File Name: SummaryStatus Acceptable
Section Name Consultant Maximum 1.000Concrete Section Hewlett-Packard Company V & T Util 0.359
N vs M Util 0.285American Building StandardsACI 318-08, "Building Code Requirements for Structural Concrete"ACI 318R-08, "Commentary for ACI 318-08"
Design Aids, Manuals, and HandbooksNotes on ACI 318-08, Portland Cement Association 2008"ACI Detailing Manual - 1994", ACI Committee 315, American Concrete Institute, 1994"Manual of Standard Practice", Concrete Reinforcing Steel Institute, 2003
Section Dimensions Material Properties Gross Properties Effective PropertiesC-Shape fc' = 5000 psi Zbar = 0.0 in Ae = 5920.0 sq.in.L1 = 240.0 in fy (panel vert) = 60.0 ksi Ybar = 70.9 in Ie (y-y) = 55750xE3 in4T1 = 10.0 in fy (panel horz) = 60.0 ksi Ag = 5920.0 sq.in. Ie (z-z) = 5921.9xE3 in4L2 = 120.0 in fy (zone vert) = 60.0 ksi Ig (y-y) = 55750xE3 in4 Ase (Y) = 3840.0 sq.in.T2 = 16.0 in fy (zone horz) = 60.0 ksi Ig (z-z) = 5921.9xE3 in4 Ase (Z) = 2400.0 sq.in.Offset = 24.0 in Wc = 150 pcf Ashear (Y) = 3840.0 sq.in. Je = 367379 in4
Ws = 500 pcf Ashear (Z) = 2400.0 sq.in.Poisson's Ratio = 0.2 Jg = 367379 in4
Quantities (approx.) hagg = 0.75 inConcrete = 6112 lb/ft Es = 29000 ksiSteel = 250.7 lb/ft Ec = 4287 ksiPrimary = 182.7 lb/ft Gc = 1786 ksiSecondary = 68.0 lb/ft fr = 530 psi
Panel 1 Zone A Zone B Zone C11-#5 @ 18.0" Vert 10-#8 Vert 8-#8 Vert 10-#8 Vert#5 @ 14.0" Horz #3 Ties @ 14.0 in #3 Ties @ 14.0 in #3 Ties @ 14.0 in
Tangential Splice Tangential Splice Tangential SpliceAs = 7.9 sq.in. As = 6.32 sq.in. As = 7.9 sq.in.
Panel 2 & Panel 3 Y: [email protected]" Y: [email protected]" Y: [email protected]"8-#5 @ 14.0" V.E.F Z: [email protected]" Z: [email protected]" Z: [email protected]"#5 @ 14.0" H.E.F.
Factored Design Sectional LoadsLoad N T Vz My Vy Mz Mres Theta
Case/Combo (kips) (k*ft) (kips) (k*ft) (kips) (k*ft) (k*ft)1 (W) -150.0 0.0 18.8 100.0 6.3 -300.0 316.2 2522 (W) -125.0 0.0 31.3 -450.0 8.8 125.0 467.0 163 (W) -75.0 0.0 25.0 -110.0 6.8 400.0 414.8 754 (W) -350.0 0.0 22.0 100.0 5.5 350.0 364.0 1065 (W) -150.0 0.0 12.5 400.0 25.0 200.0 447.2 1536 (W) -75.0 0.0 12.5 400.0 25.0 -200.0 447.2 2077 (W) -125.0 0.0 18.8 -125.0 7.8 -300.0 325.0 2938 (W) -375.0 0.0 4.8 -450.0 28.0 -75.0 456.2 351
Factored Panel Loads - Panel 1Load N1 V1 M1 Load Comment
Case/Combo (kips) (kips) (k*ft) Type1 -1000.0 200.0 2000.0 Wind
Factored Panel Loads - Panel 2
Hewlett-Packard Company Page 1User March 26, 2015
4:02 PM
-
Concrete Section S-CONCRETE Version 11.00.32 Job #A123.45 Copyright 1995-2013 by S-FRAME Software Inc.
Load N2 V2 M2 Load CommentCase/Combo (kips) (kips) (k*ft) Type
1 -1000.0 200.0 -2400.0 Wind
Factored Panel Loads - Panel 3Load N3 V3 M3 Load Comment
Case/Combo (kips) (kips) (k*ft) Type1 -1000.0 200.0 -2400.0 Wind
N vs M Results Axial Utilization Moment UtilizationGLC 1 (Panel Loading) Nu = -1000.0 kips Mu = -2400.0 k*ft Mn = -9009.0 k*ftStatus Acceptable Nn (max) = -4910.6 kips Mn = -8424.8 k*ft Mp = -10070.1 k*fUtilization 0.285 Utilization = 0.204 Utilization = 0.285Maximum 1.000Panel 2
Shear Utilization Shear in Panel 1 Shear in Panel 2 Shear in Panel 3GLC 1 (Panel Loading) Nu = -1000.0 kips Nu = -1000.0 kips Nu = -1000.0 kipsStatus Acceptable Mu = 2000.0 k*ft Mu = -2400.0 k*ft Mu = -2400.0 k*ftUtilization 0.359 Vu = 200.0 kips Vu = 200.0 kips Vu = 200.0 kipsMaximum 1.000 bw = 10.0 in bw = 16.0 in bw = 16.0 inPanel 3 d = 200.34 in d = 96.0 in d = 96.0 in
As (Tens) = 9.2 sq.in. As (Tens) = 11.09 sq.in. As (Tens) = 11.09 sq.in.Av = 0.31 sq.in. Av = 0.62 sq.in. Av = 0.62 sq.in.Lambda = 1.00 Lambda = 1.00 Lambda = 1.00Vs = 199.6 kips Vs = 191.3 kips Vs = 191.3 kipsVc = 507.1 kips Vc = 365.8 kips Vc = 365.8 kipsVn = 706.8 kips Vn = 557.1 kips Vn = 557.1 kipsUtil = 0.283 Util = 0.359 Util = 0.359
Panel 1 Reinforcing
#5 @ 18.0" Vert Vert Steel Ratio Vert Bar Spacing Number of CurtainsRho = 0.00172 S = 18.00 in Curtains Specified = 1Rho (min) = 0.00120 S (min) = 2.75 in Curtains Required = 1Rho (max) = 0.01000 S (max) = 18.00 in AcceptableAcceptable Acceptable
#5 @ 14.0" Horz Horz Steel Ratio Horz Bar SpacingRho = 0.00221 S = 14.00 inRho (min) = 0.00200 S (min) = 2.13 inAcceptable S (max) = 18.00 in
Acceptable
Panel 2 Reinforcing
#5 @ 14.0" V.E.F Vert Steel Ratio Vert Bar Spacing Number of CurtainsRho = 0.00277 S = 14.00 in Curtains Specified = 2Rho (min) = 0.00250 S (min) = 2.75 in Curtains Required = 2Rho (max) = 0.01000 S (max) = 18.00 in AcceptableAcceptable Acceptable
#5 @ 14.0" H.E.F Horz Steel Ratio Horz Bar Spacing Clear CoverRho = 0.00277 S = 14.00 in Cover Specified = 1.50 inRho (min) = 0.00250 S (min) = 2.13 in Max Cover = 5 inAcceptable S (max) = 18.00 in Acceptable
Acceptable
Panel 3 Reinforcing
Hewlett-Packard Company Page 2User March 26, 2015
4:02 PM
-
Concrete Section S-CONCRETE Version 11.00.32 Job #A123.45 Copyright 1995-2013 by S-FRAME Software Inc.
#5 @ 14.0" V.E.F Vert Steel Ratio Vert Bar Spacing Number of CurtainsRho = 0.00277 S = 14.00 in Curtains Specified = 2Rho (min) = 0.00250 S (min) = 2.75 in Curtains Required = 2Rho (max) = 0.01000 S (max) = 18.00 in AcceptableAcceptable Acceptable
#5 @ 14.0" H.E.F Horz Steel Ratio Horz Bar Spacing Clear CoverRho = 0.00277 S = 14.00 in Cover Specified = 1.50 inRho (min) = 0.00250 S (min) = 2.13 in Max Cover = 5 inAcceptable S (max) = 18.00 in Acceptable
Acceptable
Zone A Reinforcing 10-#8 Vert #3 Ties @ 14.0 in
Vertical Bar Spacing Vertical Bar Spacing Tie Spacing Splice TypeC-to-C low (y) = 5.0 in C-to-C low (z) = 5.38 in S = 14.0 in TangentialC-to-C high (y) = 5.0 in C-to-C high (z) = 5.38 in S (min) = 2.25 in AcceptableMinimum (y) = 3.5 in Minimum (z) = 3.5 in S (max) = 14.0 inMaximum (y) = 18.0 in Maximum (z) = N/A AcceptableAcceptable Acceptable
Area of Zone Steel Tie Diameter Misc InformationAs = 7.9 sq.in. d (tie) = 0.38 in Scl (limit) = 6.0 inAs (min) = N/A d (min) = 0.38 inAs (max) = 12.64 sq.in. AcceptableAg (zone) = 316.0 sq.in.Acceptable
Zone B Reinforcing 8-#8 Vert #3 Ties @ 14.0 in
Vertical Bar Spacing Vertical Bar Spacing Tie Spacing Splice TypeC-to-C low (y) = 5.25 in C-to-C low (z) = 5.0 in S = 14.0 in TangentialC-to-C high (y) = 5.25 in C-to-C high (z) = 5.0 in S (min) = 2.25 in AcceptableMinimum (y) = 3.5 in Minimum (z) = 3.5 in S (max) = 14.0 inMaximum (y) = N/A Maximum (z) = 18.0 in AcceptableAcceptable Acceptable
Area of Zone Steel Tie Diameter Misc InformationAs = 6.32 sq.in. d (tie) = 0.38 in Scl (limit) = 6.0 inAs (min) = N/A d (min) = 0.38 inAs (max) = 7.9 sq.in. AcceptableAg (zone) = 197.5 sq.in.Acceptable
Zone C Reinforcing 10-#8 Vert #3 Ties @ 14.0 in
Vertical Bar Spacing Vertical Bar Spacing Tie Spacing Splice TypeC-to-C low (y) = 5.0 in C-to-C low (z) = 5.38 in S = 14.0 in TangentialC-to-C high (y) = 5.0 in C-to-C high (z) = 5.38 in S (min) = 2.25 in AcceptableMinimum (y) = 3.5 in Minimum (z) = 3.5 in S (max) = 14.0 inMaximum (y) = 18.0 in Maximum (z) = N/A AcceptableAcceptable Acceptable
Area of Zone Steel Tie Diameter Misc InformationAs = 7.9 sq.in. d (tie) = 0.38 in Scl (limit) = 6.0 inAs (min) = N/A d (min) = 0.38 inAs (max) = 12.64 sq.in. AcceptableAg (zone) = 316.0 sq.in.Acceptable
Panel Vertical Reinf. Panel Horizontal Reinf. Zone Vertical Reinf.
Hewlett-Packard Company Page 3User March 26, 2015
4:02 PM
-
Concrete Section S-CONCRETE Version 11.00.32 Job #A123.45 Copyright 1995-2013 by S-FRAME Software Inc.
fy (min) 40.0 ksi fy (min) 40.0 ksi fy (min) 40.0 ksify (vert) 60.0 ksi fy (horz) 60.0 ksi fy (vert) 60.0 ksify (max) 80.0 ksi fy (max) 60.0 ksi fy (max) 80.0 ksiStatus Acceptable Status Acceptable Status Acceptable
Concrete Strength Concrete Density Zone Horizontal Reinf.fc' (min) 2500.0 psi Wc (min) 90.0 pcf fy (min) 40.0 ksifc' 5000.0 psi Wc 150.0 pcf fy (horz) 60.0 ksifc' (max) 10000.0 psi Wc (max) 160.0 pcf fy (max) 100.0 ksiStatus Acceptable Status Acceptable Status Acceptable
American Reinforcing Bars
Index Bar Diameter AreaDesignation (in) (sq.in.)
1 #2 0.25 0.05 2 #3 0.375 0.11 3 #4 0.50 0.20 4 #5 0.625 0.31 5 #6 0.75 0.44 6 #7 0.875 0.60 7 #8 1.00 0.79 8 #9 1.128 1.00 9 #10 1.27 1.27 10 #11 1.41 1.56 11 #14 1.693 2.25 12 #18 2.257 4.00
Wall Dimensions Lu (y-y) = 120.0 in, Lu (z-z) = 120.0 in, hw = 1200.0 in
Panel 1 Thickness Panels 2 & 3 ThicknessesT = 10.0 in T = 16.0 inT (min) = 4.8 in T (min) = 4.8 inAcceptable Acceptable
List of Messages
No Messages...
Hewlett-Packard Company Page 4User March 26, 2015
4:02 PM