burning zone ref failue

Upload: kidcat

Post on 04-Jun-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/13/2019 Burning Zone Ref Failue

    1/27

    Burning zone refractory failure

    K.P.PRADEEP KUMAR

  • 8/13/2019 Burning Zone Ref Failue

    2/27

    The coating is thin and

    washed away from the brick

    Surface. Around 9 meter area.High variation in chemistry when

    OPC clinker is switched over to

    Oil well cement or sulfate resistant

    Cement. The second reason isFormation of distorted flame which

    Eroded the coating and brick. With

    Petcoke firing the liquid becomes mor

    Viscous and destruct the bricks.

    SDCCL

  • 8/13/2019 Burning Zone Ref Failue

    3/27

    The mag chrome got eroded due to high thermo-chemical load.

    Some how alumina bricks retain the coating and prolonged condition of

    this condition would have damaged the alumina bricks too.

    Perilex-83

    Lofal -70

    9 m area

    SDCCL

  • 8/13/2019 Burning Zone Ref Failue

    4/27

    Perilex bricks at 11.5 m.

    Bricks undergone severe thermal andThermo chemical srtesses due to

    variation in clinker Chemistry.Petcoke

    under reduced conditions furtheraggravate the situation.

    SDCCL

  • 8/13/2019 Burning Zone Ref Failue

    5/27

    groove formation due to shell deformation

    Or wrong installation of key bricks. Key bricks must be just

    fit in .Too much hammering can cause damage. Not more thatwo Shims must be inserted in a ring with a gap of 3

    to 4 bricks.

    SDCCL

  • 8/13/2019 Burning Zone Ref Failue

    6/27

    Severe thermo-chemical ( high liquid %

    attack on the brick( lava formation)

  • 8/13/2019 Burning Zone Ref Failue

    7/27

    Crack on the cold face shows that

    the brick was under severe mechanical stress too

    Shell distortion at 9 M causes mechanical

    stresses on the brick.

  • 8/13/2019 Burning Zone Ref Failue

    8/27

    Grooves on the shell

    At 9 M length

    SDCCL

  • 8/13/2019 Burning Zone Ref Failue

    9/27

    Bulged portion of

    the shell at 9.0 m

  • 8/13/2019 Burning Zone Ref Failue

    10/27

    Mortar application

    to correct the

    lining at 9.0 m

  • 8/13/2019 Burning Zone Ref Failue

    11/27

    About 30 mm it has bulged

    inwards which is well

    beyond the toleralance limits.

    9.0 m area. Maximum tolrence

    Limit is +/- 10 mm.

    SDCCL

  • 8/13/2019 Burning Zone Ref Failue

    12/27

    Causes Very high variation in clinker chemistry when converted OPC clinker to

    oil well cement and sulfate resistant cement. Petcoke firing reduces the

    Viscosity of the liquid and further damage the bricks .

    Reduced conditions when petcoke is fired is extremely harmful tomagchrome bricks.

    Oil spillage on the refractory bricks and damaged the magchrome bricks.

    Coal particles was also falling on the bricks while heating.

    Kiln was rotated in the cold conditions for maintenance purpose Shell was bulged in the burning zone area.

    Refractory failure in burning zone SDCCL

    Remedies

    Frequency of change over from OPC clinker to SRC and OWC can be

    reduced by properly planning.

    The burner needs replacement. Burner tip was damaged. Oxidised

    conditions must prevail esp. when petcoke is fired.

    Kiln shell need replacement at 9 M area No job must be done after the lining is over for kiln rotation.

  • 8/13/2019 Burning Zone Ref Failue

    13/27

    Melting pit

    This happended during start-up , high percentage of

    liquid forms. The hot aggressive liquid (Lava)

    attacked the bricks , and washed the brick surface.GCW

  • 8/13/2019 Burning Zone Ref Failue

    14/27

    Bricks got soften and eroded

    due to high liquid formation

    during kiln start-up( lava)

    GCW

  • 8/13/2019 Burning Zone Ref Failue

    15/27

    Bricks got softenedand eroded. Very high

    Percentage of melt

    Formation( lava)

    GCW

  • 8/13/2019 Burning Zone Ref Failue

    16/27

    Thermo chemically attacked magchrome bricks. Sulfur penetrated the bricks.

    C

  • 8/13/2019 Burning Zone Ref Failue

    17/27

    Even the spinel brick is

    Penetrated by liquid ,in

    burning Zone, 8 15 M.Calculated liquid % is 33 .

    APCWAPCW

  • 8/13/2019 Burning Zone Ref Failue

    18/27

    Burning zone refractory failure at GCW

    Causes

    Excessive liquid formation, Lava during startup Thick coating formation due to high liquid % in clinker

    High thermal loading , >5.8 Gcal/sq M/hr

    Petcoke was tried for some time. Magchrome bricks with petcoke firing gives

    less life due to formation of low viscous liquid.Remedies

    Care must be at the time of start-up. Flame intensity can be reduced in

    the beginning to avoid over-heating.

    When thermal load is high the kiln is very sensitive to chemistry variation Hence variation in chemistry esp quartz must be controlled.

    If Pet coke is used spinel bricks are better choice.

    Note:If kiln runs stable with minimum variation in chemistry thermal load does not matter

    as coating on the bricks protects the bricks. But if the thermal loading is high and

    coating dislodges due to variation in chemistry or operational instability the

    consequent thermo-chemical load is more detrimental than the thermal load.

    .

  • 8/13/2019 Burning Zone Ref Failue

    19/27

    Refractory failure at 12 m

    After 4 months of operation. The spinel bricksunderwent severe aggressive liquid attack.( 33 % liquid)

    Li id d h i l b i k

  • 8/13/2019 Burning Zone Ref Failue

    20/27

    Liquid penetrated the spinel brick

    Slice of the spinel brick

    At 60 mm from the surface.

    APCW

    Hercynite based bricks are senstive to redox conditions

  • 8/13/2019 Burning Zone Ref Failue

    21/27

    Hercynite based bricks are senstive to redox conditions.

    The white coloration is due to redox conditions prevailing

    In the kiln. Flame needs attention. Picture taken at 7 M area

    Avoid reduced conditions. Shape the flame to get convergent and hot flameOptimize the momentum . Momentum with low % primary and high velocity

    is always better than Momentum with % primary air and low velocity.

    APCW

  • 8/13/2019 Burning Zone Ref Failue

    22/27

    Burning zone refractory failure at APCW

    Excessive liquid , > 33% causes liquid penetration deep into the bricks an

    destroy the texture of the brick , even the conventional spinel bricks.

    Reduced conditions make the coating very unstable. During coatingdislodgement it took away part of the brick.

    Remedies Optimise the liquid at around 30 -31 %.

    Use fused spinel bricks Like Almag AF and Ankral R2

    Shape the flame to avoid reduced condition

    Dislodge the rhino horn by installing proper shock blasters.

  • 8/13/2019 Burning Zone Ref Failue

    23/27

    Installation Errors

    I t ll ti

  • 8/13/2019 Burning Zone Ref Failue

    24/27

    The brick rings are

    not straight.

    Though We use

    pnemato-o-ring this

    error can occur.

    Human skill is

    also needed. Thisspinel bricks

    can undergo

    mechanical stressesand reduce the

    refractory life.

    The lining was opened

    and was corrected.

    Installation errorAPCW

  • 8/13/2019 Burning Zone Ref Failue

    25/27

    After correcting the liningAPCW

  • 8/13/2019 Burning Zone Ref Failue

    26/27

    At 11 M

    After starting the kiln within two days hot spot appeared.

    This V-gap formed due errors in installation. The brick ring must be

    perpendicular to the axis.

    HCW

    HCW

  • 8/13/2019 Burning Zone Ref Failue

    27/27

    Thanks for your kind attention

    K.P.Pradeep Kumar