building code quiz

27
Create A Quiz Quizzes o Solutions Home Create Quizzes Career Architecture Building PD 1096 NATIONAL BUILDING CODE OF THE PHILIPPINES Pd 1096 National Building Code Of The Philippines 105 Questions I By C2x_op26 + ABOUT NATIONAL BUILDING CODE MINIMUM REQUIREMENTS! Search Q uizzes

Upload: lklkjsd

Post on 15-Jan-2016

44 views

Category:

Documents


0 download

DESCRIPTION

kkj

TRANSCRIPT

Page 1: Building Code Quiz

Create A Quiz Quizzes o Solutions ▼

Home  ›  Create  ›  Quizzes  ›  Career  ›  Architecture  ›  Building  ›  PD 1096 NATIONAL BUILDING CODE OF THE PHILIPPINES

Pd 1096 National Building Code Of The Philippines105 Questions  I  By C2x_op26

+

ABOUT NATIONAL BUILDING CODE MINIMUM REQUIREMENTS!

   

Search Quizzes

Start

Page 2: Building Code Quiz

 Remove Excerpt

Question Excerpt1. –         eaves over required windows not < _____. minimum over from the side & rear

property linesA.

300 MM

B.

600 MM

C.

1000MM

D.

750MM

2.    sum of areas of openings must not exceed _____ % of sum of areas of walls

A.50B.20C.40D.603.    Distance of Exits – w/o sprinkler – ____m from exterior exit door, w/ sprinkler will

be ____mA.

45, 50

B.

30, 60

C.

45, 60

4.   Width and Height of doors will be not < _____mm in width, not < ______m in height, opening will be 90 degrees and exit way clear width not < 700mm

A.

900,2.1

B.

800, 2.0

C.

900, 2.0

5.   If arcaded bldg, no chaflan reqtd notwithstanding the width of public street,  <________m  

A.12B.13C.14D.156.     nonstructural facing brick, concrete, tile, metal, etc. attached at the backing or

structural components for the purpose of ornamentation.A.BrickB.Face

Page 3: Building Code Quiz

C.StoneD.Veneer7.  spacing of rows of seats from back to back – not < ______mm (standard

seating)A.

840

B.

850

C.

860

8.  new construction w/c increases the height or area of an existing bldg./structures.A.

Addition

B.

Renovation

C.

Revision

D.Alteration9.  inner courts shall be connected to a street or yard, or by a passageway – at least

how many  metersA.

1.0

B.

1.1

C.

1.2

D.

1.3

E.

2

10.  if only 2 exits required, shall be placed distance apart not < ____ of the perimeter area.

A.

1/3

B.

1/4

C.

1/5

11.  Foundations – not < _______ mm below the grade, may encroach ______mm into public sidewalk areas

A.600, 500B.600, 400C.500, 300D.600, 60012.  Footings must be at least _______ m below grade along national roads, may project

not >______mm beyond Property line.

Page 4: Building Code Quiz

A.

2.4, 300

B.

2.4, 400

C.

2.5, 300

D.

2.3, 400

13.  a permanent roofed structure above a door attached to and supported by the building and projecting over a wall or sidewalk

A.BalconiesB.AwningsC.

Canopies

14. 

A.

400

B.

200

C.

300

D.

500

15. Work done on any damaged/deteriorated portion of bldg.A.AlterationB.

Renovation

C.

Repair

16. Window openings for room must have at least _____% of the floor area with a minimum area of _____ sq.m.

A.20, 1B.10, 2C.10,1D.20,217. Window openings for baths and toilets must have at least ____ of the floor area with

a minimum area of _____ sq.mmA.1/20 , 250B.1/10, 240C.1/20, 240D.1/10, 24018. WHICH IS NOT INCLUDED IN THE EXCEPTION OF BUILDING PERMIT?A.

PRIVATE BUILDING

B.PUBLIC BUILDINGC.INSTITUTIONAL BUILDING

Page 5: Building Code Quiz

19. WHICH ARE NOT INCLUDED FOR THE REQUIREMENTS FOR BUILDING PERMIT

A.

The use or occupancy of proposed work

B.A description of work to be covered by the permit

C.

Description and ownership of the lot – TCT

D.Estimated cost of proposed workE.TAX DOCUMENTS20. WHAT TYPE OF CONSTRUCTION IS FOR WOOD CONSTRUCTION WITH FIRE

RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATINGA.TYPE IIB.

TYPE III

C.

TYPE IV

D.TYPE I21. WHAT TYPE OF CONSTRUCTION IS FOR WOOD CONSTRUCTIONA.TYPE IIB.

TYPE III

C.TYPE ID.

TYPE IV

22. WHAT TYPE OF CONSTRUCTION IS FOR WOOD AND MASONRY CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATING

A.TYPE IIB.

TYPE IV

C.

TYPE III

D.TYPE I23. WHAT TYPE OF CONSTRUCTION IS FOR STEEL, IRON CONCRETE

CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATING

A.TYPE VB.TYPE IIC.

TYPE IV

D.

TYPE III

24. Vertical Clearance of awning (undermost surface of the awning or GL) – not < ______m

A 3

Page 6: Building Code Quiz

.B.

2.7

C.

2.4

D.

2.8

25. Ventilation or vent shafts – horizontal cross-sectional area not <_____ sq.m per meter height of shaft 

A.0.15B.0.10C.0.20D.0.1226. This is where all on site work doneA.

Office

B.ConstructionC.

Plants

27. The width of a stair way if the occupant load of more than 50 shall not be < ____ mA.

1.2

B.

1.1

C.

1

D.

1.5

28. The width of a stair way if the occupant load of less than 50 shall not be < ____ mA.0.90B.

1

C.0.8029. The slope of an exit passage way will have a maximum slope ofA.

1/8

B.1/10C.1/1530. The slope of an exit courts will have a maximum slope ofA.1/10B.

1/8

C.1/1231. The size of room for kitchen must be at leastA.

1.5X2m

Page 7: Building Code Quiz

B.1.5x3mC.

2x3m

D.1.5x2.1m32. The size of room for human habitation must be at least an area of _____ sq.m. and

______M minimum distanceA.

6,2

B.

7,3

C.

6,3

D.

7,2

33. The size of bathrooms or toilets must be at least an area of _____ sq.m. and ______M minimum distance

A.

1.2, 1.0

B.

1.5, 0.9

C.

1.2, 0.9

34. The RATING IN  which a material can withstand fireA.FIRE RESPECTIVE RATINGB.FIRE RESISTIVE RATINGC.

FIRE PROTECTIVE RATING

35. The number of exits for Mezzanin with 185 sq.m area or more than 18m in dimension will be exits

A.

1

B.

2

C.

3

36. The number of exits for Above 1st storey with 10 occupant ____ exitsA.

1

B.

2

C.

3

37. The minimum row space with backrest  will be

A.

700

Page 8: Building Code Quiz

B.

750

C.

850

38. The maximum rise and run of the stairs will beA.200, 200B.200, 250C.200, 300D.250, 25039. The headroom clearance for stair will

beA.2.1mB.2.0mC.2.5m40. THE GENERAL PROVISION OF PD 1096 OR THE NATIONAL BUILDING CODE

OF THE PHILIPPINES ARE!A.Safe constructionB.Adequate environmental

safeguardsC.Maintain building in safe, sanitary and good working

conditionsD.ALL OF THE ABOVE41. THE ENFORCEMENT OF PD1096 ON THEIR RESPECTIVE JURISDICTION IS

THEA.MAYORB.ARCHITECTC.

BUILDING OFFICIAL

D.

CITY ENGINEER

42. The door that will be required if the exit door shall swing to exit travel in hazardous areas w/ 50 or more occupant load

A.SwingB.

Panel

C.Leaf43. The distance between 2 landings in stairs will be a maximum of A.3.0mB.3.6mC.3.5m44. THE BUILDING PERMIT WILL BE NULL OR VOID IF THE

CONSTRUCTION DIDN'T COMMENCE D THE WORK IN A PERIOD OF A.6 MONTHSB.12 MONTHSC.2 YEARSD.3 MONTHS

Page 9: Building Code Quiz

45. THE BUILDING PERMIT WILL BE NULL OR VOID IF THE CONSTRUCTION HAS BEEN ABANDONED FOR HOW MANY DAYS

A.30B.60C.

120

D.8046. Systematic dismantling of a bldg in whole or

part.A.ReinstallationB.DemolitionC.

Dismantle

47. Stair with a straight run, the landing will be a maximum of _______ m vertical distance

A.

1.5

B.

1.2

C.

1.4

48. Spacing of rows of seats from back to back  : rows of 46 seats or more (continental)

A.

450mm

B.

500mm

C.

520mm

D.

550mm

49. Spacing of rows of seats from back to back  : rows of 45 seats or less (continental)

A.

450mm

B.

500mm

C.

520mm

D.

550mm

50. Spacing of rows of seats from back to back  : rows of 35 seats or less (continental)

A.

450mm

B 500mm

Page 10: Building Code Quiz

.C.

520mm

D.

500mm

51. Spacing of rows of seats from back to back  : rows of 18 seats (continental)A.

500mm

B.

450mm

C.

520mm

D.

550mm

52. Side aisle width will be a minimum ofA.1.0mB.1.1mC.1.2mD.1.3m53. Reviewing Stands, Grandstands, and Bleachers the minimum row spacing of seats

without backrest in open air standA.

600

B.

650

C.

700

54. Public Street or alley <______m in width shall be truncated at the corner “Chaflan”

A.

3.4

B.

3.6

C.

3.5

D.

3.7

55. Private stairways that serve <10 occupants will be a minimum of _____m

A.0.60B.0.80C.0.75D.0.7056. PD 1096 WILL BE ENFORCED BY THE SECRETARY OFA.UAPB.PRC

Page 11: Building Code Quiz

C.

MUNICIPALITY

D.

PUBLIC WORKS

57. Minimum aisle width if serving only two sideA.

1m

B.1.2mC.1.5mD.

0.90m

58. Minimum aisle width if serving only one sideA.

800

B.

900

C.

700

59. Min height of mezzanine floor in metersA.1.80B.

2.0

C.1.75D.1.8560. Means "installation of components of a

building/structure"A.SecureB.ErectionC.Site work61. Maintenance and Removal of Protective Devices   protective fence or canopy shall be removed

____days after protection no longer required.  A.30B.15C.2062. Located partly in one (1) fire zone and partly in

another A.HIGH RESTRICTIVE FIRE ZONESB.

MODERATE RESTRICTIVE FIRE ZONES

C.

HIGH RESTRICTIVE FIRE HAZARDS

D.

MODERATE RESTRICTIVE FIRE HAZARDS

63. In winding stairsways, the narrower side of the tread will be __________A.150-250mmB.200-300 mm

Page 12: Building Code Quiz

C.150-300mm64. IN QUALIFICATION FOR BEING AN BUILDING OFFICIAL, YOU MUST HAVE A

DIVERSIFIED WORKING EXPERIENCE OF AN ARCHITECT OR ENGINEER FOR HOW MANY YEARS?

A.

6

B.

4

C.

5

D.

7

65. IN QUALIFICATION FOR BEING AN BUILDING OFFICIAL, YOU MUST BE A REGISTERED ?

A.ARCHITECTB.

ENGINEER

C.

URBAN PLANNER

D.LANDSCAPE ARCHITECTE.A AND B66. IN QUALIFICATION FOR BEING AN BUILDING OFFICIAL, YOU MUST BE A

MEMBER OF A ACCREDITED ORGANIZATION OF NOT LESS THAN HOW MANY YEARS

A.2 YEARSB.1.5 YEARSC.3 YEARSD.5 YEARS67. HOW MANY SETS OF PLANS AND SPECIFICATION ARE NEEDED FOR THE

REQUIREMENTS OF BUILDING PERMIT?A.

5

B.

4

C.

6

D.

7

68. HOW MANY DAYS IT WILL TAKE FOR THE ISSUANCE OF BUILDING PERMIT?A.12 DAYS UPON PAYMENTB.15 DAYS UPON PAYMENTC.14 DAYS UPON PAYMENTD.30 DAYS UPON PAYMENT69. Handrails in stairs will be _________

MMA.800-900

Page 13: Building Code Quiz

B.700-900C.

900-1200

70. Groups H, I occupancies w/o seats, line of travel to exit door by an aisle is not > ______ m

A.45B.30C.6071. For Protective Nets/Screen the G.I wire gauge must be ________mm mesh _____

net; canvasA.

16.38 MM / nylon

B.16.37 mm/ steelC.

16.39 mm/ nylon

D.16.38mm/ steel72. for Protection of Pedestrians during Construction or Demolition    Fences must

be not < _____m above gradeA.

2.3

B.

2.2

C.

2.4

D.

2.5

73. for Protection of Pedestrians during Construction or Demolition Canopies must _______m above the railway, live load 600 kg per sq.m.

A.

2.5

B.

2.6

C.

2.4

D.

2.3

74. for Protection of Pedestrians during Construction or Demolition the Temporary walkway will be at least _____m wide (during construction

A.

1.2

B.

1.3

C.

1.4

D.

1.5

Page 14: Building Code Quiz

75. for Protection of Pedestrians during Construction or Demolition the Capable of supporting a uniform live load of ____ kg per sq.m for temporary walk way

A.

600

B.

650

C.

620

D.

630

76. For Pedestrian Protection Railings in street side of the sidewalk must be at least_____m in height

A.

1

B.

2

C.

1.2

D.0.9077. For exit sign illumination the minimum lux equivalent will beA.10.7B.10.6C.10.878. For circular stair that will be used as an exit the minimum width of run will be <

______ mmA.

200

B.

250

C.

300

79. For attics the Access will be not < _____mm sq. or in diameter, min clear headroom of ____mm

A.600, 800B.800, 600C.600, 700D.700, 80080. For 599-999 occupants how many exit

neededA.

1

B.

2

C.

3

81. FIRE PUMPS WILL BE CONNECTED TO STREET MAIN W/ NOT LESS THAN 

Page 15: Building Code Quiz

A.120 MM DIAMETERB.150 MM DIAMETERC.100 MM DIAMETER82. FIRE PUMPS CAPACITY WILL BE NOTE LESS THAN A.

1000 LITERES PER MINUTE

B.

2000 LITERES PER MINUTE

C.

3000 LITERES PER MINUTE

83. FIRE PUMP PRESSURE WILL BE NOT LESS THANA.1.5 KG/ SQ CMB.2 KG/SQ.CMC.1 KG/SQ.CM84. FIRE EXTINGUISHING SYSTEM WILL BE PROVIDED FOR EVERY STOREY ,

BASEMENT OR CELLAR WHICH WILL BE USED ASA.OFFICEB.HABITATIONC.

STORAGE

85. FIRE EXTINGUISHING SYSTEM WILL BE PROVIDED FOR EVERY STOREY , BASEMENT OR CELLAR WITH AN AREA OF  

A.

300 SQ.M.

B.

250 SQ.M.

C.

200 SQ.M.

D.

350 SQ.M.

86. FIRE EXTINGUISHING SYSTEM WILL BE PROVIDED FOR EVERY STOREY , BASEMENT OR CELLAR WHICH WILL BE USED AS HABITATION WITH AN OCCUPANT LOAD OF MORE THAN 

A.30B.40C.20D.5087. Excavation made on public property - restored immediately to its former conditions

w/in _____ hrsA.48B.

120

C.12D.3688. Door leaf width will be a maximum of

______

Page 16: Building Code Quiz

A.

2.5

B.

1.2

C.

1.5

D.

1

89. Distance bet sprinklers will be max of _____ center to center

A.1.30B.1.40C.1.20D.1.8090. Construction for canopies for incombustible materials not < ____ hrs fire-

resistiveA.

1

B.

3

C.

2

D.

4

91. Ceiling heights for habitable rooms without artificial ventilation from finish floor to ceiling is

A.2.70B.2.40C.2.1092. Ceiling heights for habitable rooms with artificial ventilation from finish floor to ceiling

1st storey and onwards respectively (1st storey, 2nd storey, 3rd storey onwards) in meters

A.2.7, 2.5, 2.0B.2.7, 2.4, 2.0C.2.7, 2.4,2.193. Areas within which only certain types of buildings are permitted to be constructed

based on their use or occupancy, type of constructionA.

FIRE HAZARDS

B.FIRE ZONESC.FIRE AREAS94. Air space requirements for workshop, factories, and officesA.

3.00 cu.m w/ 1.00 sq.m of floor area per person

B.14.00 cu.m of air space per person

Page 17: Building Code Quiz

C.12.00 cu.m of air space per person

95. Air space requirements for school rooms will be

A.

3.00 cu.m w/ 1.00 sq.m of floor area per person

B.12.00 cu.m of air space per person

C.14.00 cu.m of air space per person

96. Air Ducts – ______ sq.m w/ at least dimension of 300mm

A.0.25B.0.30C.0.35D.0.4097. a written authorization granted by the BO to an applicant allowing the applicant to

proceed w/ the construction w/ specific project after plans, specs and other pertinent doc….

A.No objection certificateB.

Notice to proceed

C.Building permit98. A movable shelter supported from an exterior wall of a bldg. w/c can be retracted,

folded, collapsed against the face of a supporting bldg.A.

Canopies

B.BalconiesC.Awnings99. .  Size & Dimensions of Courts -          min. horizontal dimension – not <

________A.1.5 MB.2.5 MC.1.2 MD.2.0 M100. the clearance of Awning to curb line – not <_____mmA.

400

B.

500

C.

200

D.

300

101. secondary bldg. located w/in the same premises the use of incidental to that main bldg.

Page 18: Building Code Quiz

A.Ancillary buildingB.Extra buildingC.Expanded structure102. physical change made to increase its value & improve its aesthetic quality.A.AlterationB.

Renovation

C.

Addition

103. changes in materials, utilities, partitioning, etc but doesn’t increase the overall area thereof.

A.

Addition

B.

Renovation

C.Alteration104. change in use or occupancyA.AlterationB.

Addition

C.Conversion

105. Area Separation – enclosed attic space of combustible construction shall be divided into horizontal area max of _____ sq.m. area, _____ sq.m. in area for attic with Fire-extinguishing system. 

A.250, 750B.750, 250C.300, 750

Back to topRemove Ad  

Related QuizzesPass Taxi With Shahzoor- Office Buildings

Building Construction Quiz 1

Building Construction Part 2

Are You Building A Freak Factory?

Is IT A Condo, Plat Or Pud

Building Construction Quiz (Plumbing - Toilet Fixtures)

Related TopicsConstruction

Modernism

Home

House

Featured QuizzesWhich Lord Of The Rings Character Are You?

Page 19: Building Code Quiz

How Many Babies Will I Have?

What Is Your Personality Type On The Basis Of Your Handwriting?

The Gods And Their Spouses - Norse Mythology Couples Quiz

Am I In Love?