builders metalwork
DESCRIPTION
Builders MetalworkTRANSCRIPT
-
BUILDERSMETALWORKAPR 10
CI/SfB 21.9 Xt6
-
Page Illustration Key
SPH Joist Hangers 4 - 5 1
Maxi Speedy Joist Hanger 6 - 7 2
Speedy Joist Hangers 8 - 9 3
Straps 10 4
Herringbone Joist Struts 11 5
Truss Clip 11 6
Wall Ties 12 7
Movement, Screw-in Starter and Cavity Ties 13
Safe Edge Frame Cramp 14 8
Screw-in Frame Ties 14
Security Mesh 14 9
Flat Wire Reinforcement 15
Exmet 15
Framing Anchors 16 10
Angle Plate 17 11
Angle Brackets 18 - 20 12
Timber Connectors 21 13
BAT-U-Nailplate 21
Splice Plates 22 14
Frame Cramp 23
Sole Plate Angles 23
Junction Clip 24
BAT Safeplate 24
Multi-purpose Fixing Band 24
Soffit Vent Mesh 25 15
Scrolled Hip Irons 26
Nails 26
Gallows Brackets 26
Wall Starter/UniStarter/Multi-Starter 27 - 29
These products meet the requirements of the BM TRADACertification Scheme for Timber Engineering Hardware
Safe working loads are based upon the use of C16 drygraded timber in Service Class 1 or 2 (Eurocode 5).
Timber EngineeringHardware
Certificate Number 0004
BUILDERS METALWORKProduct Brochure
CONTENTS
8
10
-
15
911
12
13
14
2
3
4
5 6
7
1
-
EXPAMETSPH JOIST HANGERS
Design Features Single-piece, non- welded construction.
Wider masonry flange to increase loadings on masonry of
compressive strength 2.8N/mm2 and greater.
Manufactured from 2mm thick pre-galvanised mild steel to
BS EN 10327 : 2004, DX51D + Z600.
75mm load bearing surfaces.
All hangers 150mm deep and over are manufactured 10mm less to
allow for notching and regularisation of timber joists.
Gusset nail holes are non coaxial.
Standard available widths 38, 44, 47, 50, 63, 75, 100, 125, 150mm.
Installation RequirementsThe back face of hanger must be flush against the wall.
The timber joist should be square cut and butting to the back face of
the hanger (maximum permitted gap 6mm).
A minimum height of 675mm of set masonry must be in position
above the supporting flange before any load is applied.
Fixing: Nail to the joist through the nail holes in each side gusset with
BAT 3.75 x 30mm long square twisted sherardised nails.
It is recommended that joists are notched for the base of the hanger
to achieve a level surface for plasterboarding.
Type R and ST provide additional location and alignment during
construction.
HD Restraint Straps must be used with all types of SPH joist hangers
to provide lateral restraint.
How to Order/Specify BAT SPH Joist HangersTYPE S
Please state dimensions of joist
(a) depth
(b) width
e.g. SPHS22550
Minimum box quantity dependent on hanger size.
TYPES R & ST (made to order)
Please state dimensions of joist
(a) depth
(b) width
(c) top flange (to suit wall width)
e.g. SPH22550R100
Quantity made to order
4
The BAT S.P.H. Joist Hanger is a single piece timber to
masonry hanger for building into the inner leaf of external
cavity walls and internal walls.
Straddle Type ST
(ST Type is two Standard Joist Hangers joined together with Jointing Plate).
Return Type R
(R Type is a Standard type S with Return Plate added).
75mm
Standard Type S
Both the R and ST Type enables the hangers to be positioned accuratelywhilst the masonry is built above.
-
538 to 50 63 to 75 89 to 150Joist Widths (mm)Nominal Joist S.P.H. Hanger
Depth (mm) Depth (mm)
100 100 3.08 2.86 *125 125 3.21 2.98 *150 140 3.28 3.05 *175 165 3.40 3.07 *200 190 3.52 3.29 *225 215 3.65 3.43 *250 240 3.65 3.43 *275 265 3.65 3.43 *
* not availableMasonr y Strength 2 .8 N/mm2
38 to 50 63 to 75 89 to 150Joist Widths (mm)Nominal Joist S.P.H. Hanger
Depth (mm) Depth (mm)
100 100 3.13 4.29 4.47125 125 3.55 4.65 4.47150 140 3.80 4.87 4.42175 165 4.22 5.22 4.36200 190 4.63 5.58 4.31225 215 5.05 5.94 4.25250 240 5.05 5.94 4.25275 265 5.05 5.94 4.25
Masonr y Strength 7 .0 N/mm2
38 to 50 63 to 75 89 to 150Joist Widths (mm)Nominal Joist S.P.H. Hanger
Depth (mm) Depth (mm)
100 100 2.67 2.77 *125 125 2.86 2.98 *150 140 3.05 3.19 *175 165 3.25 3.40 *200 190 3.44 3.61 *225 215 3.63 3.82 *250 240 3.63 3.82 *275 265 3.63 3.82 *
Masonr y Strength 3 .5 N/mm2
38 to 50 63 to 75 89 to 150Joist Widths (mm)Nominal Joist S.P.H. Hanger
Depth (mm) Depth (mm)
100 100 2.84 2.93 4.17125 125 3.06 3.18 4.17150 140 3.19 3.33 4.08175 165 3.41 3.57 3.99200 190 3.64 3.83 3.90225 215 3.87 3.87 3.81250 240 3.87 3.87 3.81275 265 3.87 3.87 3.81
Masonr y Strength 4 .0 N/mm2
EXPAMETSPH JOIST HANGERS
Safe Working Loads of the S.P.H. Joist Hanger used with various types of masonry
-
EXPAMETMAXI SPEEDY
6
4.5
20
5560
6015
38 to 150mm 75
Type
500
*
Type
440
*
Type
560
*
Type
620
*
23
14
3540
23
38
44
14 .5
20
38 to 100mm
75
4.5
4035
Type
240
*
T ype
335
*
T ype
380
*
* For lengths see calculations in How to Order.
Bend Lines
Joist Width W
Type = Blank Length mm 240/335/380/440/500/560/620
38mm
225mm
201mmLeg Length
w
d
The Maxi Speedy is a heavy duty hanger for the support of
Timber to Timber or Timber to Masonry, Concrete, etc with
provision for Nailing or Bolting.
Design Features Manufactured from 1.5mm thick pre-galvanised mild steel to
BS EN 10327 : 2004, DX51D + Z275.
Available in 7 types: MS240; MS335; MS380; MS440; MS500;
MS560 & MS620.
Nail hole diameter: 4.5mm Bolt hole diameter: 14mm
Available widths: 38, 47, 50, 63, 75, 100mm (122 + 150 for MS500,
560 + 620 only
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sherardised nails.
M12 Bolts or Coach screws as specified by fixing manufacturer.
How to Order/Specify Maxi Speedy Joist Hangers
Steps to specify requirements:
1. Joist dimensions:
Double joist depth and add joist width, ie for joist 225 deep x 38mm
wide then:
225 (d) + 225 (d) + 38 (w) = 488mm.
2. The Maxi Speedy blank
length must be less than
total calculated in step 1,
therefore select MS44038
(not MS500 as the joist
hanger would stand
proud).
-
7EXPAMETMAXI SPEEDY
Maxi Speedy Permissible Safe Working Loads (kN)
NAILS ONLY
3.75 x 30mm long square twisted sherardised
Type No. of Nails SWLInto Face kN.
240 12 3.9
335 18 5.9
380 20 6.5
500 32 10.5
560 38 11.2
620 44 13.0
BOLTS ONLY
M12 Bolts
Type No. of Bolts SWLInto Face kN.
240 2 3.6
335 4 6.9
380 6 10.1
500 6 10.1
560 6 10.1
620 8 13.0
COACH SCREWS
12mm x 63mm long (min). USING STARTER HOLES
Type No. of Coach SWLScrews Into Face kN.
240 2 3.0
335 4 5.9
380 6 8.6
500 6 8.6
560 6 8.6
620 8 11.1
MASONRY ANCHORS
Indicative loads: refer to fixings supplier for recommended loads
Bolt No. of Bolts SWLs for Masonry Strengths ofSize Into Face
20N 15N 7N 3.5N 2.8N
12mm 2 7.2kN 5.4kN 2.5kN 1.2kN 1kN
12mm 4 14.4kN 10.5kN 5kN 2.5kN 2kN
12mm 6 21.0kN 15.5kN 7.5kN 3.7kN 3kN
-
EXPAMET SPEEDY JOIST HANGERS
8
3.8mm
L
36mm
34mm
W
0.9m
m
W = 38 : L = 70 W = 47 : L = 65 W = 50 : L = 64
Depth 100
W = 38 : L = 191 : X = 76
Depth 175
W = 44 : L = 188 : X = 73W = 47 : L = 186 : X = 71W = 50 : L = 185 : X = 70
X
Strap
22 Holes3.8mm
25mm
ShoeW
50mm
0.9mm
Side Gusset
44mm
L
Speedy Joist Hangers provide a quick and safe method of joist
trimming for light and medium duty joints.
Speedy Minor (SM)
Light duty applications. 100mm maximum joist depth to be
supported.
Short Leg (SL)
Medium duty applications. 175mm maximum joist depth to be
supported.
Standard Leg (ST) & Long Leg (LLS)
Medium duty applications. 225mm maximum joist depth to be
supported.
Speedy Girder Truss Shoe (SGTS)
Designed to offer a safe and economical method of connecting
trusses to girder units. It incorporates a specially extended bearing
surface of 85mm.
Long Leg Speedy (LLS)
Medium duty 225mm maximum joist depth. Suitable for
underslung joists (maximum 100mm drop).
Girder/Girder Speedy
For connection of girder trusses.
Design Features Speedy Hangers
Manufactured from 0.9mm thick pre-galvanised mild steel to BS EN
10327 : 2004, DX51D + Z275.
Hole diameter: 3.8mm. LLS manufactured from 1.5mm thick
material
Girder/Girder Speedy
Manufactured from 3mm thick galvanised mild steel to BS EN 1461.
Hole diameter: 22mm.
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sherardised nails
through all available nail holes.
For ease of use the legs are adjustable by hand to suit all
varying depths of supporting timber.
The depth of the supporting timber must not be less than the
hanger side gusset height.
SHORT-LEG/STANDARD-LEG SPEEDY SPEEDY MINOR
SPEEDY MINOR
Speedy Minor SM 38, 47, 50 1.6
Speedy Short Leg SL 38, 44, 47, 50 3.4
Standard Leg ST 38, 44, 47, 50, 63, 75, 100 4.3
Girder Truss Shoe SGTS 38, 44, 47, 50, 75 7.1
Long Leg LLS 38, 47, 50, 63, 75, 100 6.7
Girder/Girder Speedy GGTS 80, 105, 120, 155 See BS 5268 : Pt2
Type Joist Width Safe Working(mm) Load (kN)
How to Order/SpecifyPlease quote type reference and joist width to be carried.
SHORT LEG SPEEDY
-
W = 38 L = 281 X = 116W = 44 L = 278 X = 113W = 47 L = 276 X = 111W = 50 L = 275 X = 110W = 63 L = 268 X = 103W = 75 L = 262 X = 97W = 100 L = 250 X = 85
Strap
29 Holes3.8mm
34.5mm
Shoe
25mm
Side Gusset
W
0.9mm
50mm
L
X
Depth 225
9
EXPAMET SPEEDY JOIST HANGERS
GIRDER SPEEDY
STANDARD LEG SPEEDY (W = 38, 44, 47, 50, 63, 75, 100)
35mm
50mm
113mm107mm
W = 38 L = 396 X = 137W = 47 L = 392 X = 134W = 50 L = 390 X = 131W = 63 L = 383 X = 124W = 75 L = 377 X = 118W = 100 L = 365 X = 106
W
L
X
Depth 225
LONG LEG SPEEDY (W = 38, 47, 50, 63, 75, 100)
34 Holes3.8m m
25m m
Shoe85m m
1.2m m
Side Gusset20m m
25m
m
W = 38 L = 271 X = 115 W = 44 L = 268 X = 112W = 47 L = 267 X = 110W = 50 L = 265 X = 109W = 75 L = 252 X = 96
44m m
Strap
W
L
X
SPEEDY GIRDER TRUSS SHOE (W = 38, 44, 47, 50, 75)
3 Holes22mm
120mm
W = 80 L = 550 X = 490W = 105 L = 550 X = 490W = 120 L = 550 X = 490W = 155 L = 550 X = 490
W
X
6 Holes4mm
L
GIRDER/GIRDER SPEEDY (W = 80, 105, 120, 155)
36 nail holes
Nails:3.75 x 30mmlong squaretwistedsherardised
-
EXPAMET STRAPS
50
27.5
33
25
12.5 12.5
100
250
400
BAT straps are manufactured in two types. The Heavy Duty to
provide horizontal restraint and Standard to provide vertical
restraint against wind pressure and uplift forces.
Design Features The straps are manufactured from pre-galvanised steel strips
with zinc coated edges to BS EN 10327 : 2004, DX51D + Z275
or stainless steel to BS EN 10088-1 : 1995 : 1.4301.
Nominal Dimensions
Heavy Duty - 27.5 x 5.0mm
Standard - 27.5 x 2.5mm
Hole diameters are 6mm and they are holed at 12.5mm
grouped in threes, diagonally across the width of the strap.
STANDARD STRAP HEAVY DUTY STRAP
Dimensions
Anchorage of gable end to roofstructure.
Fixing to wall plate and wall with onebend.
Floor level straps notched into paralleljoists. Note: Gaps between masonryand adjacent joists must be packed.
Floor level straps. 150 x 650mm longonce bent and once twisted fixed toperpendicular joists.
Note: Turn down of the strap mustbe in contact with the masonry.
Installation RequirementsThe installation of restraint straps must comply with the current
Building Regulations, British Standards BS 5628 : Part 1 and Part 3
and BS 8103 : Part 1, as well as NHBC recommendations.
When straps are being fixed across joists or trussed rafters which are
parallel with the wall, and where there is a gap between the wall and
the first joist or truss, the gap must be packed. Noggins must be
provided between each joist or truss.
Fixing for Heavy Duty and Standard Straps: use either No 12 x 50mm
wood screws or 4.00 dia x 75mm corrosion resistant nails.
For stainless steel straps, stainless steel fixings must be used.
OrderingWhen ordering quote the overall length and distance of bend/twist from
END of strap. eg. overall length, bent at 100mm, bent at 250mm, twisted at
400mm. E.g. HD1000B100, ST1000T400
If in doubt, provide sketch.
10
Illustration shows the standardclockwise rotation to strap.
Anticlockwise is also possible.
-
The Bat Truss Clip eliminates the disadvantages of skew
nailing trussed rafters to timber wall plates; damaged
connector plates; split rafters or wall plates.
Design Features Manufactured from 0.9mm thick pre-galvanised mild steel to BS EN
10327 : 2004, DX51D + Z275.
Hole diameter: 4mm Height: 117mm
Available in 2 sizes:
Other thicknesses of trussed rafters may be fixed using pairs of
BAT Framing Anchors, type MFAAL and MFAAR.
Ref. Width Qty/Box Safe Working Load Uplift (kN)
TC38 38mm thick truss 200 1.3
TC50 50mm thick truss 200 0.7
EXPAMET HERRINGBONEJOIST STRUTS
TRUSS CLIP
Herringbone Joist Struts provide stability to floor joists.
Expamet Herringbone Joist Struts significantly reduce labour
content in fixing strutting on site.
Design Features Manufactured from 1mm thick pre-galvanised mild steel to BS EN
10327:2004 : DX51D + Z275.
Suitable for joist widths between 38mm and 63mm, and joist
depths between 150mm and 225mm.
Available in 3 sizes:
Installation RequirementsJoist Span 2.5m to 4.5m 1 Row at mid span
greater than 4.5m 2 Rows at 1/3 span positions
Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails.
Ref. Joist Centres Length Qty/Box
HJS400 400mm 480mm 50
HJS450 450mm 523mm 50
HJS600 600mm 660mm 50
Fixing Detail
Single 3.75 x 30mm Sheradised Square Twisted Nail
When fixing the second strut a 6mm (approx) gap should be kept between the struts.
4 Holes (both ends)
57mm
30mm
Length
12 Holes @ 4mm
38 to 50
117.5
25.5 to 31
0.9
114.3
28.5
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sherardised nails.
All nail holes must be filled.
The timber wall plate must be securely held down onto the supporting
masonry.
11
-
STAINLESS STEELWALL TIES
12
PT200#50PT200PT225#50PT225
MPT200#50MPT200MPT225#50MPT225MPT250
PT1-200PT1-225PT1-250PT1-275PT1-300
7575100100
7575100100125
75100125150150
5 x 502505 x 50250
5 x 502505 x 50250250
250250250250250
Type 4Type 4Type 4Type 4
Type 2Type 2Type 2Type 2Type 2
Type 1Type 1Type 1Type 1Type 1
200mm Housing Wall Tie200mm Housing Wall Tie225mm Housing Wall Tie225mm Housing Wall Tie
200mm General Purpose Wall Tie200mm General Purpose Wall Tie225mm General Purpose Wall Tie225mm General Purpose Wall Tie250mm General Purpose Wall Tie
200mm Heavy Duty Wall Tie225mm Heavy Duty Wall Tie250mm Heavy Duty Wall Tie275mm Heavy Duty Wall Tie300mm Heavy Duty Wall Tie
DT200DT225DT250DT300
SSCD
PTJ4115PTJ4135PTJ4165
SSFSSSFS75SSFS100
75100125150
5075100
5075100
250250250250
250
250250250
250250250
Type 2Type 2Type 3Type 3
Type 4Type 4Type 4
Type 6Type 6Type 6
200mm Double Triangle Wall Tie225mm Double Triangle Wall Tie250mm Double Triangle Wall Tie300mm Double Triangle Wall Tie
Insulation Retaining Disc. Fits all Ties.
Thin Joint Masonry TieThin Joint Masonry TieThin Joint Masonry Tie
Timber Frame Tie including nailTimber Frame Tie including nailTimber Frame Tie including nail
Type Reference NominalCavityWidth (mm)
Quantity Classification Description
Domestic up to 2 storey, 10m high. Part E (Separating Walls). Type A compliant.
PART EParty Walls
TYPE
A
PART EExternal Walls
TYPE
B
Domestic up to2 storey, 10m high. Maximum block density 550 kg/m3.
Allow for maximum heightdisplacement of 24mm.
Domestic and smallcommercial up to 15m high.
PART EExternal Walls
TYPE
B
Most masonry cavity walls.
BS EN 845-1 Wall Ties
Thin Joint Masonry Ties
Timber Frame Tie
Power-Tie Wall Ties are manufactured to comply with BS EN 845 1 thespecification for ancillary components for masonry, Part 1: ties, tensionstraps, hangers and brackets.
DD140 and EN845-1 requires specific design characteristics allowing thedesigner to specify the correct type of Wall Tie for each situation.
Wall Ties should be installed in accordance with BS 5628-3, the code ofpractise for the use of masonry, Part 3: materials and components, designand workmanship.
Stainless steel type 1.4301 to BS EN 10088-1.
For our full range of cavity wall ties and ancillary fixings please seewww.expamet.co.uk/expamet-powertie
PART EExternal Walls
TYPE
B
-
STAINLESS STEELMOVEMENT TIES
13
STAINLESS STEELSCREW-IN STARTERAND CAVITY TIES
Movement joints are necessary in masonry wall panels to cater for the naturalmovement of buildings. Tensile and compressive forces can develop that lead to cracking and bowing of walls.
BS5628-3 details the provision of movement joints in clay, calcium silicate, concrete and stone masonry.
Power-Tie Movement Ties allow expansion and contraction at movement jointswhilst providing shear resistance between adjacent panels and supports.
Placing the sleeve on the plain end of the movement tie with 10mm clearance,debonds the tie from the mortar joint, permitting longitudinal movement.
SMT200SMT225SMT250
BMT 100BMT 150BMT 200
L:200L:225L:250
L:100 / H:50L:150 / H:50L:200 / H:50
100100100
100100100
Straight Movement Tiesare built into the corresponding bed jointsof adjacent panels.
Bent Movement Ties aremechanically fixed toadjacent supports.Slotted end providesvertical adjustment.
L
L
H
Type Reference Size (mm) Quantity Description
Straight Movement Tie with debonding sleeve.
Bent Movement Tie with debonding sleeve.
SST130#10SST130
SCT 150SCT 180SCT 200SCT 225
130130
150180200225
10100
100100100100
Screw-in Starter TieScrew-in Starter Tie
Screw-in Cavity Tie with V DripScrew-in Cavity Tie with V DripScrew-in Cavity Tie with V DripScrew-in Cavity Tie with V Drip
Type Reference Length (mm) Quantity Description
SST SCT
Quick and easymethod to tie newwalls to existingwalls.
Screw-in Starter andCavity Ties are madefrom austeniticstainless steel to BS EN 10088-3.
Supplied withmasonry plug.
Nominal cavity widthfor SCT: 50 - 100mm.
-
EXPAMET SAFE EDGEFRAME CRAMPS ANDSCREW-IN FRAME TIES
14
BAT Safe Edge Frame Cramps provide positive location of
window and door frames to inner leaf of masonry.
Manufactured from pre-galvanised steel strip with zinc
coated edges to BS EN 10327:2004 : DX51D + Z275.
Fixing: use 2 No 4.5mm nails or No. 8 screws, galvanised or
sherardised.
A cost effective way of securing buildings or internal spaces by
sandwiching a layer of steel mesh into the walls and ceilings
during construction.
Available in a range of gauges this high quality security mesh
is suitable for internal walls, ceilings, partitions and external
brickwork. It can also be provided in galvanised steel, where
damp conditions are expected.
See our full range of Expanded metal and lath at
www.expamet.co.uk
2
6 Dia Holes
502610
8
19
100 / 150 / 200
50Ref. Width Length Upstand Qty/Box
SEFC150 19mm 100mm 50mm 125
SEFC200 19mm 150mm 50mm 125
SEFC250 19mm 200mm 50mm 125
Ref. Size (mm) Qty per boxMaterial
SIFT130RT
SIFT130#10
130
130
100
10 bags of 10
Stainless Steel
Stainless Steel
Screw-in Frame Ties secure timber window and door frames
to inner leaf of masonry.
SIFT 150 100Bright Zinc Plated Steel
SIFTSIFT130
50-73HFG50-73HF
50-89HRG50-89HR
50-76MFG50-76MF
(Above shown at approx 50% actual size)
EXPAMET SECURITY MESH
Description
Security Mesh - FlattenedSecurity Mesh - RaisedSecurity Mesh - Flattened
Security Mesh - FlattenedSecurity Mesh - RaisedSecurity Mesh - Flattened
MeshLW
42.950.8*43.4
42.950.8*43.4
MeshSW
14.222.6*18.0
14.222.6*18.0
StrandThickness
2.73.01.1
2.73.01.1
StrandWidth
4.63.12.3
4.63.12.3
WeightKg/m2
8.596.521.85
8.596.521.85
Sheet Size
2440 x 12202440 x 12201250 x 2500
2440 x 12202440 x 12201250 x 2500
Material
Galvanised Steel to BS EN ISO 1461Galvanised Steel to BS EN ISO 1461Galvanised Steel to BS EN ISO 1461
Hot Rolled Mild SteelHot Rolled Mild SteelCold Rolled Mild Steel
Ref.
50-73HFG50-89HRG50-76MFG
50-73HF50-89HR50-76MF
* Mesh pitch size
-
FLAT WIREREINFORCEMENTFor structural applications
EXMET REINFORCEMENTFor non-structural applications
15
Ref Material Coil Size Wall Quantity Thickness Width Width(mm) (mm) (mm)
76820 0.3 65 100 5
76920 0.3 115 140 5
77020 0.3 175 225 1
77120 0.3 225 265 1
Stainless steel Exmet is manufactured from austenitic
stainless steel 1.4301 to BS EN 10088-1. Coil length 20m.
Expanded steel mesh with no joints or interweaving to fail
under stress.
Overlap ends 75mm.
Power-Tie Flat Wire LadderReinforcement is made fromaustenitic stainless steel to 1.4301 :BS EN 10088-3.
Ladder length 2700mm.
Conforms to BS 5628-2.500N/mm2 minimum tensile strength.
Special designs are available on request for corners and T-shapes.
Reference Type Main Wire Equivalent Ladder Wall Width QtyHeight (mm) Round Wire Width (mm) (mm)
Diameter (mm)
SBSF3060 Single Leaf 2.8 3 60 100 20SBSF30100 Single Leaf 2.8 3 100 140/150 20SBSF30150 Single Leaf 2.8 3 150 190/200 20SBSF30175 Single Leaf 2.8 3 175 215 20
SBSF3560 Single Leaf 2.9 3.5 60 100 20SBSF35100 Single Leaf 2.9 3.5 100 140/150 20SBSF35150 Single Leaf 2.9 3.5 150 190/200 20SBSF35175 Single Leaf 2.9 3.5 175 215 20
SBSF4060 Single Leaf 3 4 60 100 20SBSF40100 Single Leaf 3 4 100 140/150 20SBSF40150 Single Leaf 3 4 150 190/200 20SBSF40175 Single Leaf 3 4 175 215 20
SBSF4560 Single Leaf 3 4.5 60 100 20SBSF45100 Single Leaf 3 4.5 100 140/150 20SBSF45150 Single Leaf 3 4.5 150 190/200 20SBSF45175 Single Leaf 3 4.5 175 215 20
SBSF5060 Single Leaf 3 5.0 60 100 20SBSF50100 Single Leaf 3 5.0 100 140/150 20SBSF50150 Single Leaf 3 5.0 150 190/200 20SBSF50175 Single Leaf 3 5.0 175 215 20
Overlap ends 225mm.
-
8127
60
40
15
2632
33.5
43
60
40
15
EXPAMETFRAMING ANCHORS
BAT Multi-Grip Framing Anchors offer the most effective and
economical method of providing strong, mechanical joints for
framing of timbers
Five types available: AL, AR, BL, BR and C.
MFAAL & MFAAR: for anchoring rafters and trusses to wall plate.
MFABL & MFABR: for anchoring headers to studs, beams to posts and
studs to plates.
MFAC: for right or left handed use for anchoring joists to
beams, stringers to headers and hip joints.
Design Features Manufactured from 1mm thick pre-galvanised mild steel
to BS EN 10327 : 2004, DX51D + Z275.
Overall height: 127mm
Width: 34mm
Hole dimension: 4mm
200 no. per box
Installation RequirementsFraming anchors must always be used in pairs to minimise
eccentric loading.
Recommended fixing: BAT 3.75 x 30mm long square twisted
sherardised nails.
Note: Use all available timber facing holes.
16
Safe Working Loads:
Types A & B:longitudinal capacity1.3kN/pair
lateral capacity 1.1kN/pair
Type C:longitudinal capacity3.7kN/pair
Longitudinal Loads
Lateral L
oads
108
127
60
40
15
2632
2028
55
35
10
112632
10
2820
8
127
60
40
15
2632
33.5
55
35
10
43
2926
18
292618
TYPE MFAAL
TYPE MFABL
TYPE MFAC
MFAAL(left handed)
MFABL(left handed)
MFAAR(right handed)
MFABR(right handed)
MFAC
-
EXPAMETANGLE PLATE
BAT Angle Plates are used as a safe and economical method of
connecting joists to purlins.
Design Features Manufactured from 2mm thick hot dipped pre-galvanised
mild steel to BS EN 10327 : 2004, DX51D + Z275.
Safe Working Loads: 1 pair = 3.5kN
2 pairs = 7.5kN
Ref: AP30030 300mm x 30mm x 30mm 50 per bag
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sherardised nails.
Use all timber facing nail holes.
Minimum timber depth of 150mm.
Ensure the timbers project a minimum of 50mm beyond the Angle
Plates.
17
Steel Beam
Timber packer in beam (bolted) .
150mmminimum
-
60
38
AB
18.5
5.5 12 25 5.512
12
14
14
11x30
5.5 12 5.51225
14 14
11
9
6
16
2
7 7
11
EXPAMETANGLE BRACKETS
18
BAT Angle Brackets are designed for
multi-purpose fixing applications and can be
used as replacement cleats, nailed or bolted.
Design Features Manufactured from hot dipped pre-galvanised
mild steel to BS EN 10327 : 2004, DX51D + Z275.
Light Duty: AB604060
2mm thick
Heavy Duty: HD9090; HD15090; HD150150
2mm thick, ribbed
Installation RequirementsAngle Brackets may be used for timber/timber,
timber/steel and timber/masonry connections.
May be fixed with nails, bolts or coach screws.
Must be used in pairs.
Nailed Safe Working Loads kN (per pair)
Type Uplift Shear
AB604060 1.2 1.8
HD9090 1.6 3.6
HD15090 1.4 4.6HD150150
BS 5268 Pt 2 Long term loads
Nails 3.75 x 30mm long square twisted sherardised
LIGHT DUTYRef: AB60406060mm x 40mm x 60mm 12 holes @ 4.5mm 100 no. per box
VIEW ON B
VIEW ON A
87 2
87A
B
13
42
17
27
59
59
10
7
10
17. 5 17. 5 35 10
22. 5 32 17
11x3059
Stiffening Rib
9
9
9
9
11
HEAVY DUTYRef: HD909087mm x 87mm x 59mm 16 holes @ 4mm 50 no. per box
VIEW ON B
VIEW ON A
Uplift
Shear
-
D27
63
2222.5
C
290
150
90 (TYP)
11x30
51
42
17
63
1030
3017.5
17.535
10
10 7
63
32 17
Stiffening Rib
11x30
10 17.5 17.5 35 10
7
10
9
11
9
9
9
EXPAMETANGLE BRACKETS
19
F
11x30
31
63
24
53
30
9
63
11 25 25 30 30 29
6
10
11x30
23 54 30
2
150
150
E
Stiffening Rib
26
10
10
9
9
9
9
9
HEAVY DUTYRef: HD1509090mm x 150mm x 63mm 20 holes @ 4mm 50 no. per box
HEAVY DUTYRef: HD150150150mm x 150mm x 63mm 20 holes @ 4mm 40 no. per box
VIEW ON C
VIEW ON D
VIEW ON E
VIEW ON F
-
EXPAMETANGLE BRACKETS
20
Light Duty Angle Brackets
Ref Size (mm) A x B x C Qty
AB303015 30 x 30 x 15 100
AB404040 40 x 40 x 40 100
AB505035 50 x 50 x 35 100
AB604060 60 x 40 x 60 100
AB804042 80 x 40 x 42 50
AB808018 80 x 80 x 18 50
AB906059 90 x 60 x 59 50
AB909060 90 x 90 x 60 50
AB1006060 100 x 60 x 60 50
AB12512542 125 x 125 x 42 50
AB1509059 150 x 90 x 59 50
AB15015063 150 x 150 x 63 50
Adjustable Angle Brackets
Ref Size (mm) A x B x C Qty
AAB1403540 140 x 35 x 40 50
AAB806520 80 x 65 x 20 20
Nail Plate Brackets
Ref Size (mm) A x B x C Qty
NPA767676 76 x 76 x 76 50
NPA575751 57 x 57 x 51 50
Angle Plates
Ref Size (mm) A x B x C Qty
AP2103030 30 x 30 x 210 50
AP3003030 30 x 30 x 300 50
T & L Jointing Plate
Ref Size (mm) A1 x A2 x B Qty
T1408030 140 x 80 x 30 20
L12012020 120 x 120 x 20 20
Flat Jointing Plate
Ref Size (mm) A x B Qty
JP17559 175 x 59 50
JP46250 250 x 46 50
JP63300 300 x 63 50
C
A
B
C
A
B
CA
B
C
A
B
B
A1
A2B
B
A1
BA
A2
B
-
EXPAMETTIMBER CONNECTORS
21
SHEAR PLATE 102 SHEAR PLATE 67
Shear PlateManufactured in 2 sizes: SPT67 (B2) x 150 per box and SPT102 (B3) x
50 per box
Designed for use with M20 bolt.
Material Specification:
67mm Manufactured from galvanised hot rolled steel to
BS EN 10025.
100mm Galvanised cast iron to BS EN 1562.
Square Plate WashersManufactured in 1 size: SPW50 (50mm square). To suit 12mm bolt.
250 per box.
Bolts are not supplied with timber connectors.
Tooth Plate (Round)Manufactured in 3 sizes:
50, 63 and 75 diameter. 200, 150
and 100 per box respectively.
Available in both single and
double sided, eg. ref. TCSS (C6);
TCDS (C7) etc.
Suitable for M12 bolt.
Material Specification:
Manufactured from pre-galvanised
steel to BS EN 10327 : 2004
DX51D + Z275.
Split RingManufactured in 2 sizes:
SRTC64 (A3) x 100 per box and
SRTC102 (A3) x 100 per box
Designed for use with M12
and M20 bolts respectively.
Double bevelled.
Material Specification:
Manufactured from galvanised
hot rolled steel to BSEN10025.
BAT Timber Connectors are made in accordance with the
requirements of BS EN 912 : 2000 specification for connectors
for timber. Safe working loads, end distances and spacing are
all set out in BS 5268 Part 2.
Application Tools For use with timber connectors.Available to special order.
REF TYPE SIZE mm
SRGT/64 Split Ring Grooving &Dapping Tool 64mm split ring
SRGT/102 Split Ring Grooving &Dapping Tool 102mm split ring
DT/67 Shear Plate Grooving &Dapping Tool 67mm shear plate
DT/102 Shear Plate Grooving &Dapping Tool 102mm plates
BAT-U-NAIL PLATE
3. 5
50 .8
12.7
DIRECTION OF STIFTENING RIBS
19 4.75
1.5
76
114
152
51100
152203
254
305
354
BAT-U-Nail is a plate system which enables timber structures
to be made on site or in the builders workshop, since it is
nailed by hand.
Design Features Manufactured from 0.9mm pre-galvanised mild steel to
BS EN 10327: 2004 : DX51D + Z275.
Widths: 76, 114 and 152mm
Lengths: 51, 100, 152, 203, 254, 305 and 354mm.
Various quantities per box. Ref. eg. BP7651.
Installation RequirementsBAT-U-Nail plates are to be fixed on both sides of the timber.
Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails
Loading in the direction of the plate stiffening ribs.
345 N/nail (parallel to timber grain).
145 N/nail (perpendicular to timber grain).
Plate compression value 40 N/mm width of plate. To calculate
capacity of connections, the lesser of anchorage, plate compression
and tension should be taken.
Fix in accordance with BS 5268 : Part 2.
-
EXPAMETSPLICE PLATES
22
Suitable for butt jointing timbers of similar cross section.
Design Features Manufactured from 1.2mm thick pre-galvanised mild steel to
BS EN 10326 : 2004 S280GD + Z275.
Available in 3 types:
L61 61 x 400mm long up to 150mm deep joist
L80 80 x 560mm long up to 200mm deep joist
L98 98 x 560mm long up to 250mm deep joist
8 sets of 4 per box (32 pieces) including nails.
Installation RequirementsJoint consists of 4 pieces.
All nail holes must be used.
Minimum timber thickness 50mm.
Can be used for:
Replacement of rotten and decayed floor joist ends.
Replacement of fire damaged structural timbers.
Making good localised damage or decay in structural timber work.
61mm
18mm
L61
400mm
80mm
18mm
L80560mm
98mm
18mm
L98
560mm
Timber Joist
Existing Joist
Joist Splice Plate Splice Plate Resistance Shear Approx. NailsDepth Code Size (mm) Moment (kNm) Capacity (kN) per plate
125 L61 18 x 61 x 400 1.5 13 27150
175 L80 18 x 80 x 560 1.5 13 52200
225 L98 18 x 98 x 560 1.5 13 65250
-
EXPAMETFRAME CRAMP
23
SOLE PLATE ANGLES
BAT Sole Plate Angles positively locate timber sole plates to
concrete floor slabs using masonry fixings as required, without
penetrating the dpc.
Design Features Manufactured from 0.9mm thick hot dipped galvanised
mild steel to BS EN 10327 : 2004 DX51D + Z275.
Available in 2 sizes:
Installation RequirementsBAT Sole Plate Angles may be fixed on the inside of the sole plate or
alternatively fixed under the sole plate with the upstand on the
outside of the sole plate.
Fixing: use 3.75 x 50mm minimum length nails/masonry nails.
To provide positive location and support of window from
timber framing to resist wind and incidental loadings.
Design Features Manufactured from 0.9mm thick hot dipped galvanised
mild steel to BS EN 10327 : 2004 DX51D + Z275.
Available in 2 sizes:
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sheradised nails.
Ref. Width Length Upstand Qty/Box
FC1 76mm 202mm - 100
FC2 76mm 212mm 40mm 100
PLAN VIEW
SECTION VIEW
Ref. Width Length Upstand Qty/Box
SPA112 76mm 112mm 40mm 100
SPA162 76mm 162mm 40mm 100
-
EXPAMETJUNCTION CLIP
24
MULTI-PURPOSEFIXING BAND
Can be used instead of noggins, at wall junctions and atcontact points between ceiling and walls when fitted at300mm centres.
Design Features Manufactured from 1mm hot dipped galvanised mild
steel to BS EN 10327 : 2004 : DX51D + Z275.
Ref: JC1 250 per box.
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sherardised nails or
ordinary plasterboard nails.
For protection of plumbing and electrical wiring againstrandom nailing into studs.
Design Features Manufactured from 1mm hot dipped galvanised
mild steel to BS EN 10327 : 2004 : DX51D + Z275.
Ref: SAF1 90 x 54mm 200 per box
Installation RequirementsUse wherever services occur within 75mm of face of plasterboard or
100mm of surface of floor deck. Fixing: Tap in with hammer.
Expamet Fixing Band is an easy-to-use coil strip designed forall types of light fixing applications.
Design Features Manufactured from hot dipped galvanised mild steel to
BS EN 10327 : 2004 DX51D + Z275.
Available in 3 sizes
Installation RequirementsFixing: use BAT 3.75 x 30mm long square twisted sherardised nails,
screws or bolts. Not to be used below ground.
BAT SAFEPLATE
Pipe fixing, Generalsupport & Duct work
58Pitch
17
29
12
413.8 Dia6.25 Dia
4
Clamping, Bracing &Restraining
Timber repair...Fencing, Garden Sheds etc
Ref. Width Thickness Length
MFBA 20mm 0.9mm 10 metre coil
MFBB 20mm 0.7mm 10 metre coil
MFBA/20 20mm 0.9mm 20 metre coil
-
EXPAMETSOFFIT VENT MESH
25
The provision of eaves vents to limit condensation risk is arequirement of the Building Regulations.
Expamet expanded stainless steel is used over the vents toexclude birds and insects. This mesh is an economical materialfor the purpose. It is readily adaptable to various eavesdetails, is light in weight and easy to handle on site. Coils of mesh in convenient dispensers make site work easier andavoid wastage.
Design Features Manufactured from stainless steel to
BS EN 10088-1 : 2005 : 1.4404.
Approx. weight 0.370kg/m2.Ref: SVM1 30m x 75mm.
Installation RequirementsStainless steel nails or staples should be used for fixing the eaves vent mesh.
Closed area 34%. The vent gap should be increased to 15mm or 38mm to compensate.
Mesh fixed to rear of fascia board
Mesh bent to shape required
Mesh held in position by soffit board
Soffit mesh fixed along the back of fascia board
Predrilled ventilation hole
Mesh fixed to rearof fascia priorto fixing fasci
Mesh bent to shape required and compressed to fill gap on fixing of fascia board
Mesh is fixed to rafter ends, bent and returned to underside
Fascia and soffit boards are then fixed
75 x 50mm fixing block
Soffit board rebated to fascia board
Mesh fixed to soffit board prior to fixing of soffit board
Mesh bent to shape required
Examples of Applications
-
EXPAMETSCROLLED HIP IRONS
26
NAILS
GALLOWS BRACKETS
Designed to provide decorative restraint when bedding hip tiles.
Ref Material Length x Width x Thick Height
HIP2003 Galvanised 200mm x 25mm x 3mm 100mm
HIP2503 Galvanised 250mm x 25mm x 3mm 150mm
HIP3003 Galvanised 300mm x 25mm x 3mm 150mm
HIP3004 Galvanised 300mm x 25mm x 4mm 150mm
Stainless Steel Annular Ring NailsSSRN 3.35 x 50mm 1000 per box
Sherardised NailsSN32 BAT 3.75 x 30mm twisted 1000 per box
SN321 BAT 3.75 x 30mm twisted 10000 per box
The Gallows Bracket provides a method of supporting
otherwise unsupported brickwork.
Manufactured from 50 x 50 x 5 angle, red oxide finish.
Three sizes are available (supplied in pairs).
To suit M12 Masonry Anchors - not supplied.
Red Oxide:
MH375375 375mm high x 375mm deep (projection from wall)
MH490375 490mm high x 375mm deep (projection from wall)
Height
Height
Depth
LengthWidth
Thick
-
EXPAMET WALL STARTERS, UNISTARTERS AND MULTI-STARTERS
27
The quick, easy-to-fix way to tie-in new walls to existing walls
without cutting out brickwork. Suitable for walls of up to three
storeys high, ie up to 8m maximum.
Wall Starters
Ref Description Type Wall Thickness
WS060 Stainless Steel Single Flange Integral Tie 60 - 75mm
WS090 Stainless Steel Single Flange Integral Tie 100 - 115mm
WS120 Stainless Steel Single Flange Integral Tie 125 - 180mm
WS185 Stainless Steel Single Flange Integral Tie 190 - 260mm
WGC060 Plastisol Coated Galv Single Flange Integral Tie 60 - 75mm
WGC090 Plastisol Coated Galv Single Flange Integral Tie 100 - 115mm
WGC120 Plastisol Coated Galv Single Flange Integral Tie 125 - 180mm
WGC 185 Plastisol Coated Galv Single Flange Integral Tie 190 - 260mm
UniStarters
UWSS Stainless Steel No Flange Integral Tie Up to 250mm
UWGC Plastisol Coated Galv No Flange Integral Tie Up to 250mm
Multi-Starters
MSSS Stainless Steel No Flange Turn-n-slide Ties Up to 250mm
MSGC Plastisol Coated Galv No Flange Turn-n-slide Ties Up to 250mm
MSGFIX Plastisol Coated Galv Extra Fixing Pack
MSGFIX Stainless Steel Extra Fixing Pack
Contains 10 ties, 5 screws, plugs & washers
Stainless SteelRef. WS060
Plastisol CoatedGalvanised SteelRef. WGC060
For lightweightblock walls 60to 75mm thick.
Stainless SteelRef. WS090
Plastisol CoatedGalvanised SteelRef. WGC090
For brick or blockwalls 100to 115mm thick.
Stainless SteelRef. WS120
Plastisol CoatedGalvanised SteelRef. WGC120
For brick or blockwalls 125to 180mm thick.
Stainless SteelRef. WS185
Plastisol CoatedGalvanised SteelRef. WGC185
For brick or blockwalls 190to 260mm thick.
Wall StartersIndividual products designed for specific widths of
new walls
There are four flanged products in the Expamet Wall Starter range,
each designed for a specific wall widths, from 60mm to 260mm thick.
UniStartersThe universal wallstarter for any wall
The flat flange-free design of Expamet UniStarters means they can
be used to construct any wall between 75mm and 250mm thick
one product, multiple applications.
Stainless SteelRef. UWSS
Plastisol CoatedGalvanised Steel Ref. UWGCAll Wall Starters, Unistarters and Multistarters are supplied with the necessary fixings.
-
28
EXPAMET WALLSTARTERS & UNISTARTERSFIXING INSTRUCTIONS
675
fixingpoints
drill, plug and fixusing fixingssupplied
The distance between the flangessets the cavity width.
Tie-line
Tie-line
Tie-line
Tie-line
Dimension to suit centralisingof UniStarters in leaves of new wall.
25
eitherholemay beused
eitherholemay beused
slot flat slot
joining adjacent Wall Starters, and UniStarters
450
675
450
WALL STARTERSCAVITY WALLS Brick & Block
The left hand Wall Starter is fixed with its ties extending upwards ready
for bending down into the mortar courses. The right hand Wall Starter is
inverted and fixed with the ties extending downwards.
They must then be bent upwards ready for setting into the mortar course
as the wall is built.
UNISTARTERSCAVITY WALLS Brick & Block
UniStarters are fixed with their ties extending upwards ready for bending
down into the mortar courses. The right hand UniStarter is higher to allow
the tie to bed into the first blockwork mortar course.
Wall Starter & UniStarter Installation
Suitable for both metric and imperial brick/block sizes.
Integral ties are designed to tie into every (225mm deep) block
course or every third course of (75mm deep) bricks.
Each pack contains two 1175mm lengths. Slotted holes at each end
allow easy connection of one length to the next.
Full fixing instructions and all necessary coach screws, washers
and plugs are provided. Only 5 fixings are needed for the two
lengths (Type 120 and 185 Wall Starters are supplied with
10 fixings). The only tools you need are: spirit level, drill (with
10mm masonry bit) and 10mm spanner.
Miscoursing of up to 50mm can be solved by simply bending
integral ties to suit. This will reduce the length of built-in tie, but
it still meets relevant test criteria.
All products are designed to allow up to 10mm vertical movement.
If the upper end of the product extends past the top line of your
wall, use tin-snips or a hacksaw to cut off the excess and attach
using the remaining top fixing hole.
Align the centreline of the UniStarter with the centre of the new
wall. Align the flanged edge of the Wall Starter to the front or back
of the new wall.
For cavity walls, each leaf will require a separate starter.
All external walls require a 10mm wide weather seal to be fitted
between the product and the existing wall or applied to the
raked-out vertical joint.
In exposed locations (or to meet Local Authority specifications),
a vertical DPC should be cut into the existing wall prior to fixing
the product.
-
EXPAMET MULTI-STARTERS
29
Multi-StartersFeaturing a turn-n-slide tie to accommodate all sizes of
brick/block.
The Multi-Starter is suitable for all wall widths from 60mm-250mm.
Installation The turn-n-slide ties enable the starter to be tied into any course
the builder wishes, ideally every (225mm deep) block course or
every third course of (75mm deep) bricks.
Each pack contains two 1165mm lengths. Slots at each end allow
easy connection of one length to the next.
For more information see Wall Starter & UniStarter installation
details on previous page.Stainless SteelRef. MSSS
Plastisol Coated Galvanised Steel Ref. MSGC
Fixing Details
Joining adjacentMulti-Starters
Fixing points
675
450
675
450
Drill, plug and fix using fixingssupplied
Insert Turn (anti-clockwise)
Slide
For Masonry MovementJoint applications use Expamet MovementTies.
PLUMBEnsure existing wall is sound and clean.Locate the starter above the DPC.Plumb the section and mark positionsof the fixing holes.
DRILLDrill and plug the existing wall, takingcare to avoid mortar joints.
FIXLightly screw the first length to theexisting wall over weatherseal if required,then plumb, mark and drill out the nextstarter. Make sure that the slot at the endof one length always lies on top of theslot of the adjacent length. Tighten allscrews when all required lengths arein position.
BUILDLay bricks or blocks, be sure to bed themwith mortar against the starter.Multi-Starter: Turn-n-slide ties into themortar as you build.Wall Starters and UniStarters: Bend tiesinto the mortar as you build.Seal vertical joint with proprietary flexiblesealant.
-
30
1. IDENTIFICATION
Expamet Construction Fixings
Expamet Building Products Limited
Greatham Street
Longhill Industrial Estate (North)
Hartlepool TS25 1PR
Tel: +44 (0)1429 866688
Fax: +44 (0)1429 866633
2. HAZARDS IDENTIFICATION
Possible cuts from steel edges.
Toxic and irritant fumes from high temperatures.
3. COMPOSITION
Galvanised steel
DX51D+Z275 to BS EN 10327: 2004
DX51D+Z600 to BS EN 10327: 2004
S280GD+Z275 to BS EN 10326: 2004
Stainless steel
1.4301 to BS EN 10088-1: 2005
4. FIRST AID MEASURES
Skin and eye contact: treat cuts from steel edges as required.
Ingestion: not applicable.
Inhalation: remove from source of fumes and dust.
5. FIRE FIGHTING MEASURES
Non-flammable material.
6. ACCIDENTAL RELEASE MEASURES
Not applicable.
7. HANDLING AND STORAGE
Bands and straps must not be used for lifting.
Use suitable PPE when handling the Construction Fixings.
Assess manual handling risks before lifting.
Construction Fixings should be stacked on firm level ground
in dry conditions.
8. EXPOSURE CONTROLS
Wear personal protection such as gloves and safety goggles
when handling products.
Some products may have a film of soluble cutting fluid after
manufacture; therefore carry out personal hygiene, including
proper washing of hands, after contact.
9. PHYSICAL AND CHEMICAL PROPERTIES
Construction Fixings are supplied in various lengths,
widths and gauges.
Metallic grey appearance.
10. STABILITY AND REACTIVITY
Construction Fixings are stable under normal conditions but
if subjected to high temperatures, fumes are produced.
11. TOXICOLOGICAL INFORMATION
High temperatures can produce fumes.
12. ECOLOGICAL INFORMATION
No known hazard.
13. DISPOSAL CONSIDERATIONS
Recycle or dispose of in accordance with Waste Management
Licensing Regulations.
14. TRANSPORT INFORMATION
Not classified as hazardous for transport.
15. REGULATORY INFORMATION
Construction Fixings are articles and have no obligations
under REACH.
16. OTHER INFORMATION
All products must be installed in accordance with Expamet
Building Products published instructions.
Where structural products are to be removed from an
existing installation, care must be taken to ensure that the
procedure does not compromise the loading/installation
restrictions applicable to the products.
The Construction Fixings Health and Safety Data Sheet is not
a product specification guide.
CONSTRUCTION FIXINGSHEALTH AND SAFETYDATA SHEET
Any arrangement of construction fixings shown in this brochure is indicative only. Actual fixing installations must comply with current Health and Safety requirements.
-
QUALITY YOU CAN TRUSTExpamet are not only industry leaders in the UK, but we also operate in continental Europe and the Middle East, giving
us a strong continental presence. You can be assured that wherever you are you can source a range of Expamet
building products.
EXTENSIVE PRODUCT RANGEExpamet Building Products Limited is the parent company of a number of great brands with each brand committed to
quality in its particular product field.
Expamet Construction - One stop shop for metalwork for the construction industry
BAT Builders metalwork products
Expamet Plasterers accessories
Hy-Rib Permanent formwork for concrete
Power-Tie Wall ties and ancillary fixings
Expamet Express Our new next-day delivery service
TECHNICAL AND SALES SUPPORTExpamet provide a comprehensive pre and post-sales support service. From product advice and training through
to design and implementation. Our sales and technical support teams have a wealth of construction and engineering
experience and are available for both on and off-site support.
For more information call us on +44 (0)1429 866655.
Order before 1pm and we will despatch your order for next working day delivery,
direct to branch or site.
See www.expamet.co.uk for full details
-
Quality Assurance BS EN ISO 9001:2008 and ISO 14001 2004 Registered Firms Certificate No. FM36694, EMS 45225
EXPAMET BUILDING PRODUCTS LIMITED
UK SALES AND DISTRIBUTION CENTRE
Greatham Street, Longhill Industrial Estate (North),
Hartlepool TS25 1PR England
Tel: Sales: +44 (0)1429 866611 Sales Fax: +44 (0)1429 866622
E-mail: [email protected]
General: +44 (0)1429 866688 Fax: +44 (0)1429 866633
Technical: +44 (0)1429 866655
Tech E-mail: [email protected]
Website: www.expamet.co.uk
IRISH SALES OFFICE
DUBLIN: Unit 7, Swords Business Park, Swords, Co. Dublin
Tel: +353 (0) 1890 2392 Fax: +353 (0) 1890 2220
E-mail: [email protected]
Expamet operate a continuous development programme and we reserve the right to amend specification without prior notification.
Please note, some products are not manufactured by Expamet and are therefore excluded from registration to BS EN 9001: 2008.
Please contact the technical department for further information.
All copyright, trade marks and unregistered design rights for the products detailed in this brochure are the property of Expamet Building Products Ltd.