bts commissioning alcatel lucent

Upload: nguyen-huu-luong

Post on 31-Oct-2015

412 views

Category:

Documents


73 download

DESCRIPTION

Commissioning BTS Alcatel A9100 Offline, Online and TrubleShooting

TRANSCRIPT

  • Switch OFF the

    BTS cabinet and

    disconnect Abis

    connectors from

    DDF before offline

    start

  • Disconnect

    the Abis

    connector

    from The DDF

  • Switch ON the

    BTS cabinet

    breakers and

    connect the

    Laptop with

    BTS

  • User Name COMMTE

    Password COMMTE

  • Communication Port setting

  • OR

  • After connecting this window

    will be appear

  • Go to

    Configuration->

    BTS-SW

    Download->

    to download

    BTS software

  • After BTS-SW

    download this window will appear

  • Go to offline Files and select

    First File of Master File.

  • Go to offline Files and select

    First File of DDL file.

  • Click ok to start

    downloading SW

  • BTS software starts to

    download.

  • All these Files are

    downloaded

  • Go to Configuration

    BTS commissioning

  • Click start commissioning

  • Edit Qmux Address

  • Edit sector Mapping

  • Check All Twin TREs.

  • Click End Commissioning

    Click

  • All modules Shifted to

    update modules.

  • Click No to end

  • Reconnect the

    Abis connector at

    DDF by verifying

    the TX/RX cables

    properly

  • Give Hard Reset to

    BTS cabinet as the

    OML has established

    to put the site on

    Downloading.

  • OFF Line Commissioning

    Completed

    Successfully.

  • BTS ON-Line commissioning Procedure using B10

    Go to configuration>>

    Hardware setting>>Begin

    HW modification

  • Go to configuration>

    BTS commissioning

    Go to start commissioning> Edit Q1 Address,

    Edit Sector Mapping and Twin TRA

    setting as in offline.

  • Go to configuration>

    Hardware setting>End

    Modification to end online

    commissioning

  • Online commissioning steps

    Connect the Abis connector at DDF by verifying Tx/Rx cable properly.

    OML will be established after primary Abis has connected to DDF.

    Give hard reset to BTS after OML has established.

    Put site on Downloading from OMC.

    O&M will be established as downloading completes.

    Connect Laptop to BTS MMI port.

    Go to configuration>Hardware setting>Begin Hardware modification.

  • Online commissioning steps Go to configuration>BTS commissioning>start

    commissioning. Edit Qmux Address Edit sector mapping Check all Twin TRA setting. Click end commissioning and shift all modules from selected

    modules to available modules. Go to configuration>Hardware setting>End Hardware

    modification. Click yes when an automatically hardware modification

    window appears. Hw Audit will be run and all Hardware will be shown after

    sometime.

  • ON Line Commissioning

    Completed

    Successfully.

  • Software components combiner Fan Unit

    Tres

    clock

    Alarm card

    Hardware Shown in software window

  • Alarms window

  • Transceivers Shown in window

  • Transceivers Types Four type of Transceivers in Alcatel Equipment

    TRAGE>Gsm Single TRE

    TRADE>Dcs single TRE

    TGT09>Gsm Twin TRE

    TGT18>DCS Twin TRE

    TAGHE>High power TRE

  • VSWR Shown in window

  • Sectors Shown

    In window

  • Station units

  • BSC SBLs (security block levels) BTS OM & Sectors.Sec

    RSLs can be unlock from local Terminal.

  • Troubleshooting If a TRE or combiner is in Not Operational or FOS state then

    disable it then initialize it by using init command. If TRE or combiner can not operational by doing above command

    then remove it by using the following method. Go to configuration>>Hardware setting>>Begin HW modification. Go to Configuration>>Hardware setting>>Remove. Remove the Hardware from BTS. Window will be appear of Hardware removal, select the module to

    remove. Go to Configuration>>Hardware setting>>End Modification. Click yes when configuration changes window appears.

  • Hardware Removal Method Step:1

  • Hardware Removal

    Step:2

  • Hardware Removal

    Step:3

  • Troubleshooting cont.. When a module goes in FOS state then it must be disable by

    using disable command before initializing it by using init command otherwise it will not goes to operational state.

    When a module is in Not Operational state with color white then it means it has not got its RSL number still. Reload BTS data by going to configuration>Reload Bts data or using a method of Begin Hardware then End Hardware as discussed earlier. It will take some time to become operational.

    When a module is in MSD or MSA state then it will not get any command because its maintenance has seized for a while.

    When TRE RSL has locked then then its RSL will not be stable, so unlock the TRE from OMC.

  • Troubleshooting cont.. Sometime there is some faulty hardware in Bts thats why other

    sectors or TREs can effect and can not work properly. Due to these faulty hardware other sectors or TREs can be down so simply remove this hardware. By this method other hardware become in operational state.

    Some time SUMA can not work properly thats why whole Bts effects so change the slot of SUMA and give hard reset to Bts.

    If modules in a shelf can not powers up then check its power cable at the back ports of Bts or check it RI cable. Also check the power switch for the concern shelf.

    If a EACB card is Not operational or FIT state then initialize it from software. If it again goes in FIT state then Alarm card is faulty.

  • Troubleshooting cont.. Some time Primary Abis is stable by showing LED on Suma card

    but OML can not become stable, It means that Abis LED is fake. So check the Tx/Rx cable from both Bts end and microwave end and make sure that it is correctly connected. Also check Tx/Rx patching on DDF by using LED. Make sure that LED blinks on every pair on DDF. Also check the BNC and Abis connectors. Abis cable which is connected from Suma card to Bts board can be faulty so also verify it.

    If a TRE or combiner can not operational than change its slot then verify it.

    Vswr issues can be resolved by checking connectors from Bts end and feeder end.

    The last option for Alcatel equipment to become operational is the Hard reset of Bts.

  • External Alarms of MBO2

  • ALCATEL GLOSSARY A AN Antenna Network B BCB BTS Control Bus BSII Base Station Controller BSS Base Station Subsystem BTS Base Station Transceiver BTSW BTS-Terminal for Windows C CCF Cabinet Cooling Fan CDM Configuration Data Message CLEI Common Language Equipment CLLK Clock Link CPF Configuration Parameter File CRC Cyclic Redundancy Check CU Carrier Unit

  • ALCATEL GLOSSARY D DC Direct Current DMA Deferred Maintenance Alarm E EQU Equipped F FIA Format Identifier for Application part of RI FIM Format Identifier Manufacturing FIT Faulty In Traffic FLT Faulty FOS Faulty Out of Service ICS Item Change Status IT In Traffic L LDA Local Defence Action LRA Local Recovery Action M MI Maintenance Information MSA MSD Auto MSD Maintenance Seized

  • ALCATEL GLOSSARY N

    NEQ Not Equipped

    NOP Not Operational

    O

    O&M Operation and Maintenance

    OMU Operation and Maintenance Unit

    OMUA OMU A RIT

    OMUB OMU B RIT

    OP Operational

    OPR Operator

    P

    PADD Physical Address

    PMA Prompt Maintenance

  • ALCATEL GLOSSARY R

    RA Radio Access

    RF Radio Frequency

    RFH Radio Frequency Hopping ( also known as : Synthesizer Hopping )

    RI Remote Inventory

    RIT Replaceable Item

    RX Receiver or receive .....

    RTC Remote Tunable Combiner

    S

    SBL Security Block Level

    SCFE Station Unit Control Function Entity RIT

    SOS System Out of Service

    SUM Station Unit Module

    SUMP SUM PCM RIT

    SW Software

  • ALCATEL GLOSSARY S SBL Security Block Level SCFE Station Unit Control Function Entity RIT SOS System Out of Service SUM Station Unit Module SUMP SUM PCM RIT SW Software T TLV Tag, Length, Value TRE Transceiver Module (combined Transmitter / Receiver

    functionality for base band and RF signals) TS Timeslot TX Transmitter or transmit . V VPMA Very Prompt Maintenance Alarm VSWR Voltage Standing Wave Ratio

  • ALCATEL GLOSSARY W

    WBC Wide Band Combiner

    WTC Wait Traffic Clear

    X

    XBCB External BCB

    XCLK External Clock

    XIOB External Input Output Board