bs en 14351-1:2006 - vbhgb. · pdf filethis report in issued in accordance with our terms and...

18
This report in issued in accordance with our terms and conditions, a copy of which is available on request. Exova Warringtonfire Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : [email protected] W: www.exova.com Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429 BS EN 14351-1:2006 Test of: Restrictors- 5701-211/212 5701-220/221 5701-235/236 5701-240/241 5701-242/243 5701-244/245 5970-713/714 Windows and doors – Product standard, performance characteristics A Report To: Yale Door and Window Solutions Document Reference: WIL 326594 Date: 22/03/2013 Copy: 1 Issue No.: 1 Page 1

Upload: phungkhuong

Post on 08-Mar-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

This report in issued in accordance with our terms and conditions, a copy of which is available on request.

Exova Warringtonfire Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA

T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : [email protected] W: www.exova.com

Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429

BS EN 14351-1:2006

Test of: Restrictors- 5701-211/212 5701-220/221 5701-235/236 5701-240/241 5701-242/243 5701-244/245 5970-713/714

Windows and doors – Product standard, performance characteristics A Report To: Yale Door and Window Solutions Document Reference: WIL 326594

Date: 22/03/2013

Copy: 1

Issue No.: 1 Page 1

Document No.: WIL 326594 Page No.: 2 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.2 of 18

BS EN 14351-1:2006

TEST CONCLUSIONS

Samples of: Manufacturer Yale Door and Windows Solutions Product Side hung window with fixed light fitted with various restrictors Models 5701-211/212

5701-220/221 5701-235/236 5701-240/241 5701-242/243 5701-244/245 5970-713/714

have been tested in accordance with: BS EN 14351-1:2006 By Exova Warringtonfire Willenhall, a UKAS accredited Testing Laboratory (No. 0621) and EC Notified Body number (No. 1104) At Key Industrial Park, Fernside Rd, Willenhall, West Midlands, WV13 3YA. Results and comments as detailed below:

Clause No. Description Compliance

4.8 Load bearing capacity of safety devices – 350N Yes No inferences can be made regarding performance against other requirements of this standard

Tests marked “ N/A” are not applicable to the sample under test. Tests marked “N/T” were not applied to the sample under test

Document No.: WIL 326594 Page No.: 3 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.3 of 18

BS EN 14351-1:2006

AUTHORISATION Tests performed by: Chris Bryan, Test Engineer

Report issued by: Chris Bryan, Test Engineer

Signed Date 22nd March 2013 For and on behalf of Exova Warringtonfire

Report authorised by: Mark West, Assistant Operations Manager

Signed Date 22nd March 2013 For and on behalf of Exova Warringtonfire

Report issued: 22 March 2013

NOTE. Tests marked “Not UKAS Accredited” are not covered by the Laboratory UKAS accreditation schedule. Tests marked NT were not tested Tests marked NA are not applicable to the product on test. The laboratory has tested the product supplied by the client as sampled in accordance with their own requirements

Exova Warringtonfire is an EC Notified Body Number 1104

This report shall not be reproduced except in full, (and then only as permitted by copyright laws), without written approval from Exova Warringtonfire

Document No.: WIL 326594 Page No.: 4 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.4 of 18

BS EN 14351-1:2006

CONTENTS PAGE NO.

TEST CONCLUSIONS ................................................................................................................ 2

AUTHORISATION ...................................................................................................................... 3

TEST DETAILS .......................................................................................................................... 5

TEST PROCEDURE ................................................................................................................... 6

SCHEDULE OF COMPONENTS ................................................................................................. 7

PERFORMANCE CRITERIA & TEST RESULTS ......................................................................... 10

CONCLUSIONS ....................................................................................................................... 17

LIMITATIONS .......................................................................................................................... 17

REVISION HISTORY ................................................................................................................ 18

Document No.: WIL 326594 Page No.: 5 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.5 of 18

BS EN 14351-1:2006

TEST DETAILS CLIENT DETAILS Company name Yale Door and Window Solutions Address School Street

Willenhall West Midlands

Postcode WV13 3Pw Contact Paul Jelley ORDER DETAILS Order number 784066 Dated 28/02/2013 SAMPLE DETAILS Product Side hung window with restrictors Restrictor Models 5701-211/212

5701-220/221 5701-235/236 5701-240/241 5701-242/243 5701-244/245 5970-713/714

Manufacturer Yale Door and Window Solutions Frame Dimensions 1200 x 1200 mm Sash Dimensions 560 x 1170 mm Material PVC-u Details of Hardware Hinges Lock

Securitsyle Defender Egress Yale DWS Encloser

Markings None Date of Manufacture Unknown Other information None TEST DETAILS Test specification BS EN 14351 :2006 Full test No Test to clauses 4.8 Test Method BS EN 14609:2004 strength of safety devices Sample received 28/02/2013 Test started 28/02/2013 Test completed 28/02/2013 Special Test requirements

None

Other reports to be used in conjunction with this report

None

Document No.: WIL 326594 Page No.: 6 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.6 of 18

BS EN 14351-1:2006

TEST PROCEDURE Introduction This test report should be read in conjunction with the Standard BS EN 14351-

1:2006: Windows and doors – Product standard, performance characteristics – Part 1: Windows and external pedestrian door set’s with out resistance to fire and/or smoke leakage characteristics.

The specimens were judged on their ability to comply with the performance criteria as required in BS EN 14351-1:2006, with test methods BS EN 14609.

Instruction To Test

The test was conducted on the 28th February 2013 on behalf of Yale DWS.

Mr Paul Jelley, a representative of Yale DWS witnessed the test.

Initial requirement was as defined in BS6375-2, requiring a performance of a threshold value of 350N for load-bearing capacity of safety devices.

Test Specimen Construction

A description of the test construction is given in the Schedule of Components. The description is based on a detailed survey of the specimens and information supplied by the sponsor of the test.

Sampling The samples were not independently witnessed or selected and were provided direct from the test sponsor.

Installation The sample was supplied mounted within a timber sub-frame of nominal section 75mm x 100mm fitted flush with the exterior face, in accordance with the clients fitting instructions.

Test Climate The sample was conditioned in the laboratory in the range 10-30 °C and 25-75% humidity.

The temperature and humidity in the lab was maintained in the range 15.3-19.4°C and 28.8-46.7% humidity for the duration of the test.

Document No.: WIL 326594 Page No.: 7 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.7 of 18

BS EN 14351-1:2006

SCHEDULE OF COMPONENTS (Refer to Figures 1 to 3) (All values are nominal unless stated otherwise) (All other details are as stated by the sponsor)

Variants None

Item

Description

1. Window frame head

Supplier : Eurocell

Profile code : EWS 7021

Material : PVC

Density : kg/m3 (stated)

Overall section size : 1200 x 1200

Rebate : 20mm

Fixing jamb to head joints : Fusion Welded

2. Window frame jamb

Supplier : Eurocell

Profile code : EWS 7002

Material : PVC

Density : kg/m3 (stated)

Overall section size : 1200 x 1200

Rebate : 20mm

Fixing jamb to sill joints Fusion Welded

3. Window frame mullion

Supplier : Eurocell

Profile code : EWS 7002

Material : PVC

Density : kg/m3 (stated)

Overall section size :

Rebate : 20mm

Fixing mullion to head & sill joints : Fusion Welded

4. Window frame weather seals

Supplier : Eurocell – Co-Extruded

Document No.: WIL 326594 Page No.: 8 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.8 of 18

BS EN 14351-1:2006

Item

Description

5. Window casement (s) Overall Size

i. side hung sash : Yes

ii. fixed sash : Yes Supplier : Eurocell

Profile codes

i. stile profile code : EWS 7004 ii. rail profile code : EWS 7004

iii. mid rail profile code : N/A

Material : PVC

Density : kg/m3 (stated)

Sash framing section sizes 1200 x 1200 overall

i. rail :

ii. stile : Corner fixing method : Fusion Welded

6. Window casement glass

Supplier : Eurocell

Thickness : 4/20/4 (28mm)

7. Glazing setting blocks

Supplier : Eurocell

8. Glazing gasket Supplier : Eurocell

Fixing method : Co-extruded

9. Hinges Supplier : Securistyle

Description : Defender Egress

Reference : EDSE12 Quantity : 2 Fixing hinge to sash iii. type : Gimlet point iv. size : 25mm v. quantity : 3 Fixing hinge to frame i. type : Gimlet Point ii. size : 25mm iii. quantity : 3

10. Lock

Supplier : Yale DWS

Description : Encloser

Reference : YWBL6-2209R-19 Fixings

i. type : Gimlet Point

ii. size : 25mm

iii. quantity : 10

Document No.: WIL 326594 Page No.: 9 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.9 of 18

BS EN 14351-1:2006

Item

Description

11. Lock Keeps

Supplier : Yale DWS

Description : Mushroom Keep

Reference : YWK218-19

Quantity : 3

Fixing keeps to frame i. type : Gimlet Point ii. size : 25mm

iii. quantity : 2 (per keep)

12. Lever handles Supplier : Yale DWS

Description : In-line lever handle Reference : AMA3024WA Material : Zinc Die Cast

Fixings

i. type : M5

ii. size : 40mm

iii. quantity : 2

13. Restrictor Supplier : Yale DWS

Description : Window Restrictor

Reference : As listed Fixing restrictor to sash i. type : Gimlet Point ii. size : 25mm iii. quantity : 2 Fixing restrictor to frame i. type : Gimlet Point ii. size : 25mm iii. quantity : 2

Document No.: WIL 326594 Page No.: 10 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.10 of 18

BS EN 14351-1:2006

PERFORMANCE CRITERIA & TEST RESULTS Clause Result Pass/Fail

Restrictor

5701-211/212

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 11 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.11 of 18

BS EN 14351-1:2006

Clause Result Pass/Fail

Restrictor

5701-220/221

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 12 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.12 of 18

BS EN 14351-1:2006

Clause Result Pass/Fail

Restrictor

5701-235/236

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 13 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.13 of 18

BS EN 14351-1:2006

Clause Result Pass/Fail

Restrictor

5701-240/241

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 14 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.14 of 18

BS EN 14351-1:2006

Clause Result Pass/Fail

Restrictor

5701-242/243

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 15 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.15 of 18

BS EN 14351-1:2006

Clause Result Pass/Fail

Restrictor

5701-244/245

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 16 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.16 of 18

BS EN 14351-1:2006

Clause Result Pass/Fail

Restrictor

5970-713/714

4.8 Load-bearing capacity of safety devices

The restrictor latch was engaged and a load was applied at the restricted leading edge of the window. The load applied was 350N and was held for 60 seconds.

The restrictor continued to operate after the test.

PASS

Document No.: WIL 326594 Page No.: 17 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.17 of 18

BS EN 14351-1:2006

CONCLUSIONS Evaluation against objective

The sample as provided by the client was subjected to operational & strength testing in accordance with BS EN 14351-1:2006 and achieved the requirements of clause 4.8 Load-bearing capacity of safety devices.

Observations & comments

LIMITATIONS

Limitations The results relate only to the behaviour of the specimens of the element of construction under the particular conditions of test. They are not intended to be the sole criteria for assessing the potential performance of the element in use, nor do they reflect the actual behaviour in use.

Range of window assemblies covered by this report

It is our opinion that the range of window assemblies covered by this report are limited to the following

� Assemblies with identical hardware fitted no further apart than in the tested assembly

� Assemblies of the same or smaller overall dimensions to the tested assembly

Uncertainty of Measurement

The uncertainties of measurements calculated for a confidence level of 95% throughout these tests are within the limits of these tolerances.

The standard specifies the following tolerances

� Forces: ±2%

� Distances: ±1mm for tape measures ± 0.01mm for dial gauges

� Times: ±5s

Document No.: WIL 326594 Page No.: 18 of 18

Author: C Bryan Issue Date: 22/03/2013

Client: Yale DWS Issue No.: 01

Document No.RS91 Issue No.1 Sheet No.18 of 18

BS EN 14351-1:2006

REVISION HISTORY Issue No : Re - Issue Date :

Revised By: Approved By:

Reason for Revision:

Issue No : Re - Issue Date :

Revised By: Approved By:

Reason for Revision:

END OF REPORT