    Introduction Most of the test procedures collected in this manual were specially prepared for the geotechnical laboratory of DGM in Thimphu, Bhutan The test procedures are based on BS standards and some ASTM standards. However, in various cases the test procedure was adapted to the type of equipment available in the laboratory. This means that often a realistic compromise had to be found between strict requirements and practical possibilities. Warning: Whenever tests have to be performed following a prescribed standard, always consult that standard before testing. Version February 2004 W. Verwaal References Head, K.H. (1982): Manual of Soil Laboratory Testing. Vol. 1, Pentech Press, London, Plymouth. Head, K.H. (1982): Manual of Soil Laboratory Testing. Vol. 2, Pentech press. London, Plymouth. Bowels J.E. (1978): Engineering properties of soils and their measure mends, second edition. McGraw-

    Hill books company. Whitlow, R. (1983): Basic soil mechanics, Construction Press, London and New York. Annual Book of ASTM Standards, volume 04.08 : Soil and Rock (I) Published by ASTM in 2000 BS 5930:1999 British Standard Institution BS 1377:1990 British Standard Institution, part 1-8 Some Internet pages. .

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 3

    CONTENTS 1.1 CLASSIFICATION OF SOIL BS 5930:1999 SECTION 6 ........................................................................ 4

    2.1 SIMPLE DRY SIEVING BS 1377: PART 2:1990. .................................................................................. 10

    2.2 WET SIEVING - FINE SOILS BS1377: PART 2:1990. ......................................................................... 14

    2.3 HYDROMETER TEST BS 1377: PART 2:1990 ..................................................................................... 18

    THE ATTERBERG LIMITS ............................................................................................................................ 23

    3.1 LIQUID LIMIT WITH CASAGRANDE CUP. BS 1377: PART 2:1990 AND ASTM, 1995. D4318 ... 24

    3.2 LIQUID LIMIT USING THE CONE PENETROMETER BS 1377: PART 2:1990 .............................. 27

    3.3 PLASTIC LIMIT BS 1377: PART 2:1990................................................................................................ 30

    4.1 DENSITY BS 1377: PART 2:1990 ............................................................................................................ 32

    4.2 NATURAL MOISTURE CONTENT BS 1377:PART 2,1990 ................................................................ 34

    5.1 PARTICLE DENSITY BS 1377: PART 2 1990 ....................................................................................... 35

    5.1 VANE TEST BS 1377: PART 7 1990........................................................................................................ 38

    5.2 TRIAXIAL TEST BS 1377: PART 8 1990 ............................................................................................... 40

    5.3 DIRECT SHEAR TEST BS 1377: PART 7 1990..................................................................................... 46

    6.1 CONSOLIDATION TEST BS 1377: PART 5: 1990................................................................................ 51

    7.1 PROCTOR TEST BS 1377: PART 4: 1990.............................................................................................. 56

    7.2 CALIFORNIAN BEARING RATIO TEST BS 1377: PART 4:1990..................................................... 61

    PERMEABILITY TESTS.................................................................................................................................. 66

    8.1 CONSTANT HEAD TEST BS 1377: PART 5: 1990 ............................................................................... 67

    8.2 FALLING HEAD PERMEABILITY TESTS. ........................................................................................... 73

    9.1 POCKET PENETROMETER, HEAVY DUTY PENETROMETER ..................................................... 75

    9.2 HAND VANE TESTER PILCON............................................................................................................... 76

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 4

    1.1 Laboratory classification of soil BS 5930:1999 section 6 Introduction It is necessary to provide a classification of types of soil for the purpose of describing the various materials encountered in site exploration. The system needs to be comprehensive, while still being reasonable, systematic and concise. There are many different classification systems. The system we will use is the British soil classification with some addings from the ISO 14688. Procedure This classification can be separated in different parts. First there is a preliminary classification to determine whether the soil was laid down by natural processes No MADE GROUND Yes NATURAL SOIL Next: Does the natural soil comprise organic materials, have it organic odour? Yes ORGANIC SOIL. Next: Is the soil of low density? Yes VOLCANIC SOIL Next: Remove all cobbles and boulders (>63mm). Do they weight more than the rest of the soil? Yes: are most particles >200mm? Yes BOULDERS No COBBELS No: Does the soil stick together when wet: No: are most particles >2mm Yes GRAVEL No SAND Yes: Does soil: Display low plasticity, Dilatancy, silky touch, Disintegrate in water and Dry quickly Yes SILT No CLAY Classification in practice The primary classification of natural soil can be done by a wet sieving procedure on a 63 m sieve if more then 35% of the material is passing you are dealing with a fine grained soil if less than 35 % of the sample is passing you are dealing with a course grained soil. During the second part of the classification you have to determine the complete grading curve for coarse-grained soil and the Atterberg limits for fine-grained soils, (determined on the part smaller than 425m). The 35% boundary between fine and course is approximate. Due to engineering behaviour its sometimes necessary to determine de plasticity of soil with a fine-course boundary below 35% fines. Classification of fine grained soils (soils that stick together when wet) Since the plasticity of fine-grained soils has an important effect on such engineering properties as strength and compressibility, plastic consistency is used as a basis for their classification. The consistency of a soil is its physical state characteristic at given moisture content. Four consistency states may be defined for cohesive soils: solid, semi-plastic solid, plastic and liquid. The change in volume of a saturated cohesive soil is approximately proportional to a change in moisture content; the general relationship is shown in fig. 1.1.2

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 5

    Fig 1.1.2 Consistency relationships. The transition from one state to the next in fact is gradual; however, it is convenient to define arbitrary limits corresponding to a change over moisture content: LL = the liquid limit: the moisture content at which the soil ceases to be liquid and becomes plastic. PL = the plastic limit: the moisture content at which the soil ceases to be plastic and becomes a semi-plastic SL = the shrinkage limit: the moisture content at which drying-shrinkage at constant stress ceases. The two most important of these are the liquid and plastic limits, which represent respectively the upper and lower bounds of the plastic state; the range of the plastic state is given by their difference, and is termed the plasticity index (PI). PI = LL-PL This value is reported to the nearest whole number. If it is not possible to perform the plastic limit test, the soil is reported as nonplastic (NP). This also applies if the plastic limit is equal to or greater than the liquid limit. Which can occur in some soils with high mica content. The relationship between the plasticity index and the liquid limit is used in the British Soil Classification System to establish the subgroups of fine-grained soil; fig. 1.1.3 shows the plasticity chart used for this purpose. The A-line provides an arbitrary division between silts and clays, and vertical divisions (of percentage liquid limit) define five degrees of plasticity: C = clay M = Silt for organic soil add O to symbol

    Fig 1.1.3 Plasticity chart for classification of fine soils.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 6

    Low plasticity: LL 90% A given soil may be located in its correct sub-group zone by plotting a point, having co-ordinates given by the soils plasticity index and liquid limit. The sub-group symbols are given in Table 1.1.4 Fine-grained soils F = FINES L = low plasticity (undifferentiated) I = intermediate plasticity M = SILT H = high plasticity C = CLAY V = very high plasticity E = extremely high plasticity Organic soils Pt = peat O = organic Table 1.1.4 sub-group symbols in British Soil Classification system. The liquid limit is determined with the cone penetrometer method (part 3.2 of this handbook).or with the Cassagrande cup (part 3.1 of this handbook). The plastic limit is determined with the "rolling" method (part 3.3 of this handbook). Classification of coarse grained soils For the classification of coarse-grained soils it is necessary to make a particle-size analysis. Figure 1.1.5 shows the British Standard range of particle sizes. Determining the weight percentages falling within bands of size represented carries out the particle size analysis of a soil by these divisions and sub-divisions. It can be done by dry sieving (part 2.1 of this handbook), or by wet sieving (part 2.2 of this handbook). Fine grained Coarse grained Clay Silt Sand Gravel Stone Colloids Fine Medium Coarse Fine Medium Coarse Fine Medium Coarse Cobbles Boulder 1 6 20 200 600 6 20 200 2 60 2 60 m

    mm

    Fig 1.1.5 British Standard range of particle sizes

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 7

    The grading curve is a graphical representation of the particle-size distribution and is therefore useful in itself as a means of describing the soil. From the grading curve we can provide a descriptive term for the type of soil (SOIL NAME). BOULDERS-COBBELS Main name Estimated boulder or cobble

    content of very course fraction BOULDERS Over 50% is of boulder size

    (> 200mm) Over 50% of material is very course (>60mm)

    COBBLES Over 50% is of cobble size (200 mm to 60 mm)

    Mixtures of boulders or cobbles and finer material Term Composition BOULDERS (or COBBLES) with a little finer material up to 5% finer material BOULDERS (or COBBLES) with some finer material 5% to 20% finer material BOULDERS (or COBBLES) with much finer material 20% to 50% finer material FINER MATERIAL with many boulders (or cobbles) 50% to 20% boulders (or cobbles) FINER MATERIAL with some boulders (or cobbles) 20% to 5% boulders (or cobbles) FINER MATERIAL with occasional boulders (or cobbles) up to 5% boulders (or cobbles) The description of the finer material (FINER MATERIAL) is made accordance the standard SAND and GRAVEL Term Principal soil type Approximate proportion of

    secondary constitution SAND Or GRAVEL

    Slightly sandy or gravelly Sandy or gravely Very sandy or gravelly

    SAND and GRAVEL

    up to 5% 5% to 20% over 20% about equal proportions

    Mixtures of sand and/or gravel with silt or clay

    Approximate proportion of secondary constitution Term Principal soil type Coarse soil Coarse and/or fine soil

    Slightly clayey or silty and/or sandy or gravelly Clayey or silty and/or sandy or gravelly Very clayey or silty and/or sandy or gravelly

    SAND And/or GRAVEL

    >5% 5% to 20%A >20% A

    Very sandy or gravelly Sandy and/or gravelly Slightly sandy and/or gravelly

    >65%B 35% to 65%

  • 14/06/2005 Soil mechanics laboratory manual 8

    A further quantitative analysis of grading curves may be carried out using certain geometric values known as grading characteristics. First of all, three points are located on the grading curve to give the following characteristic sizes (fig. 1.1.7):

    Fig 1.1.7 Grading characteristic. D1 0 = maximum size of the smallest 10% of the sample D30 = maximum size of the smallest 30% of the sample D60 = maximum size of the smallest 60% of the sample From these characteristic sizes, the following grading characteristics are defined: Effective size, d10

    Uniformity coefficient, Cu = 10

    60

    DD

    Coefficient of gradation (curvature) Cc = ( )

    D10*D60D 230

    Cu < 3 indicate a uniform soil. Cu > 5 indicate a well-graded soil. Most well graded soils will have grading curves that are mainly flat or slightly concave, giving values of Cc between 0.5 and 2.0. Cc

  • 14/06/2005 Soil mechanics laboratory manual 9

    Fig 1.1.6 typical particle size distribution curves BS description system A recommended protocol for describing a soil deposit uses nine characteristics; these should be written in the following order: compactness e.g. loose, dense, slightly cemented bedding structure e.g. homogeneous or stratified; dip, orientation discontinuities spacing of beds, joints, fissures weathered state degree of weathering colour main body colour, mottling grading or consistency e.g. well-graded, poorly-graded; soft, firm, hard SOIL NAME e.g. GRAVEL, SAND, SILT, CLAY; (upper case letters) plus silty-, gravelly-, with-fines, etc. as appropriate soil class (BSCS) designation (for roads & airfields) e.g. SW = well-graded sand geological stratigraphic name (when known) e.g. London clay Not all characteristics are necessarily applicable in every case. Example: (i) Loose homogeneous reddish-yellow poorly-graded medium SAND (SP), Flood plain alluvium (ii) Dense fissured unweathered greyish-blue firm CLAY. Oxford clay.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 10

    2.1 Simple dry sieving BS 1377: Part 2:1990. Scope of the test Dry sieving is the simplest of all methods of particle size analysis. According to the British Standard dry sieving may be carried out only on materials for which this procedure gives the same results as the wet sieving procedure. This means that it is applicable only to clean granular materials, which usually implies clean sandy or gravely soils that is, soils containing negligible amounts of particles of silt or clay size. If in doubt about the validity of the dry-sieving method, the wet-sieving procedure should be followed instead. If particles of medium gravel size or larger are present in significant amounts, the initial size of the sample required may be such that riffling is necessary at some stage to reduce the sample to a manageable size for fine sieving. The procedure is then referred to as "composite sieving". Sample preparation The specimen to be used for the test is obtained from the original sample by riffling, or by subdivision using the cone-and-quarter method. The appropriate minimum quantity of material depends upon the maximum size of particles present, and is indicated in Table 2.2-1 - The specimen is placed on a tray and is allowed to dry, preferably overnight, in an oven maintained

    at 105-110 C. - After drying to constant weight, the whole specimen is allowed to cool, and is weighted to an

    accuracy within 0.1% or less of its total mass (M1).

    Maximum size of material present in substantial proportion

    retained on BS sieve (mm)

    Minimum mass of sample to be taken for sieving

    Pass 2 mm or smaller 100g

    6.3 200g

    10 500g

    14 1kg

    20 2kg

    28 6kg

    37.5 15kg

    50 35kg

    63 50kg

    75 70kg

    100 150kg

    150 500kg

    200 1000kg

    Table 2.1-1 Minimum quantities for particle size test.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 11

    Execution of the test Selection of sieves. The complete range of sieves specified by the British Standard is given in Table 2.1-2 It is not necessary to use all sieves for every test, but the sieves used should adequately cover the range of aperture sizes for each particular soil. For classification purposes we can use a short set. The sieves to be used are selected to suit the size of sample and type of material. Sieve frames must not be out of true, and should fit snugly one inside the other, to prevent escape of dust. Sieves are nested together with the largest aperture sieve at the top, and a receiving pan under the smallest aperture sieve at the bottom. Aperture size Standard Short full set set set Suitable sieve diameters Construction A B C 450mm 300mm 200mm Perforated 75 mm + + Steel plated 63 + + + (Square holes) 50 + 37.5 + + + 28 + + 20 + + + + 14 + 10 + + 6.3 + + + 5 + Woven wire 3.35 + + + 2 + + (+) + + 1.18 + + 600 m + + (+) + + 425 + 300 + + 212 + + 150 + + 63 + + (+) + + Lid and receiver + + +

    19 sieves 13 sieves 7 sieves Table 2.1-2 metric sieves Test procedure - The dried soil sample is placed in the topmost sieve and is shaken long enough that all particles

    smaller than each aperture size can pass through. This can be achieved most conveniently by using a mechanical sieve shaker.

    - The whole nest of sieves with receiving pan is placed in the shaker, the dried soil is placed in the top sieve, which is then fitted with the lid, and the sieves are securely fastened down in the machine.

    - Agitation in the shaker should be for a minimum period of 10 min. Some shakers have a built-in timing device which can be pre-set to switch off the motor automatically after the desired period.

    - The maximum mass of sample, which can be sieved in one cycle, is depending on the used sieves and the particle size of the sample. See table 2.1-3.

    - Weighing, The material retained on each sieve is transferred to a weighed container. Any particles lodged in the apertures of the sieve should be carefully removed with a sieve brush, the sieve being first placed upside-down on a tray or a clean sheet of paper. These particles are added to those retained on the sieve. Weighing of each size fraction should be to an accuracy of at least 0.1% of the total initial test sample mass. The masses retained (Ms1, Ms2, etc.) are recorded against the sieve

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 12

    aperture size on the particle size test work sheet. The mass (Mp) passing the 63mm sieve is also measured and recorded.

    Sieve Aperture

    450mm

    diameter sieves (kg)

    Maximum mass 300 mm

    diameter sieves (kg)

    200 mm

    diameter sieves (g)

    50 mm 10 4.5 37.5 8 3.5 28 6 2.5 20 4 2.0 14 3 1.5 10 2 1.0 6.3 1.5 0.75 5 1.0 0.5 3.35 300 2 200 1.18 100 600m 75 425 75 300 50 212 50 150 40 63 25 Table 2.1-3 maximum mass to be retained on each test sieve at the completion of sieving. Calculations The mass retained on the first sieve is denoted as Ms1. The mass passing the first sieve = M1- Ms1. The percentage passing the first sieve is given by

    1 111

    M MsP 100 %M=

    The mass passing the second sieve = M1 Ms1 Ms2. The percentage passing the second sieve is given by

    ( )

    % 100 M

    MsMsMP1

    2112 +=

    And so on. The percentage passing any subsequent sieve can be written as

    % 100M

    MM P1

    1 = Where M denotes the sum of the masses retained on all sieves down to and including the one in question: M = Ms1+Ms2+Ms3+ etc. The calculated mass passing the last sieve should be equal, or very nearly equal, to the mass collected in the receiving pan. If this is denoted by Mp, the percentage of fines, Pp passing the last sieve is

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 13

    Pp = 1M

    Mp * 100 %

    Reporting In addition to the particle size curve and the usual sample identification data, the sheet should include the visual description of the sample. This should be the description of the sample before testing, and modified as necessary as a result of the additional information revealed by the test result. Any material removed before sieving, such as vegetation or an isolated cobble, should be reported. Tabulated data showing the percentage each sieve are sometimes required instead of, or in addition to, the grading curve. The method of test is reported as dry sieving in accordance with BS 1377:1975, Test 7(B).

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 14

    2.2 Wet sieving - fine soils BS1377: Part 2:1990. Scope of the test If a soil contains silt or clay, or both, even in small quantities, it is necessary to carry out a wet sieving procedure in order to measure the proportion of fine material present. Even when dry, fine particles of silt and clay can adhere to sand-size particles and cannot be separated by dry sieving, even if prolonged. Washing is the only practicable means of ensuring complete separation of fines for a reliable assessment of their percentage. If clay is present, or if there is evidence of particles sticking together, the material should be immersed in a dispersant solution before washing. The dried representative sample is spread out on a tray and covered with water containing 2g/litre of sodium hexametaphosphate. The soil is allowed to stand for at least an hour, and is stirred frequently. This disperses the clay fraction, so that clay and silt will not adhere to larger particles. The procedure is described in detail below for non-cohesive soils containing little or no gravel. Sample Preparation - The specimen to be used for the test is obtained from the original sample by rifling, or by

    subdivision using the cone-and-quarter method. The appropriate minimum quantity of material depends upon the maximum size of particles present, and is indicated in Table 2.2.1 Page.

    - The specimen is placed on a tray and is allowed to dry, preferably overnight, in an oven maintained at 105-110 C After drying to constant weight, the whole specimen is allowed to cool, and is weighted to an accuracy within 0.1% or less of its total mass (M1).

    Execution of the test - Selection of sieves. The complete range of sieves specified by the British Standard is given in Table 2.2.2 It is not necessary to use all sieves for every test, but the sieves used should adequately cover the range of aperture sizes for each particular soil. For classification purposes we can use a short set.

    Maximum size of material present in substantial proportion

    retained on BS sieve (mm)

    Minimum mass of sample to be taken for sieving

    Pass 2 mm or smaller 100g 6.3 200g 10 500g 14 1kg 20 2kg 28 6kg

    37.5 15kg 50 35kg 63 50kg 75 70kg

    100 150kg 150 500kg 200 1000kg

    Table 2.2-1 Minimum quantities for particle size test.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 15

    Aperture size Standard Short full set set set Suitable sieve diameters Construction A B C 450mm 300mm 200mm Perforated 75 mm + + Steel plated 63 + + + (square holes) 50 + 37.5 + + + 28 + + 20 + + + + 14 + 10 + + 6.3 + + + 5 + Woven wire 3.35 + + + 2 + + (+) + + 1.18 + + 600 m + + (+) + + 425 + 300 + + 212 + + 150 + + 63 + + (+) + + lid and receiver + + + + +

    19 sieves 13 sieves 7 sieves Table 2.2-2 metrics sieves - Sieving coarse material The sample is sieved on a large-diameter 20 mm sieve, with a portion being taken at a time, so as not to overload the sieve (see Table 2.2-3 ). Particles retained are brushed to remove finer material which may be adhering to them, but individual particles must not be broken down. The material retained on the 20 mm sieve, after drying, if necessary, is then sieved on appropriate larger aperture sieves and the amount retained on each is weighed. The fraction passing the 20 mm sieve, including "brushings" from larger particles, is then oven dried and weighed (M2). If M2 is much more then 2 kg the sample is subdivided to give a convenient mass M3 for the remainder of the sieving operation. - Wash. The 2 mm sieve is nested in the 63mm sieve, but the lid and receiver are not used. An additional intermediate sieve may be included to protect the 2mm and 63mm sieve from overloading if the soil contains a high proportion of coarse or medium sand. The soil is placed a little at a time on the 2 mm sieve, and washed over a sink with a jet or spray of clean water. The silt and clay passing the 63 mm sieve is allowed to run to waste. When the material on the 2 mm sieve has been washed free of fines, washing on the 63mm sieve is continued until the wastewater is seen to run clear. During this operation the sieve must not be allowed to become overloaded with soil or to overflow with water. The mass of soil retained on the 63mm should not exceed 150 g at any one time. Table 2.2-3 gives the recommended maximum quantities that may be retained on each sieve. If this is likely to be exceeded, the material should be sieved in two or more portions. Warning: The sink used for this operation should be fitted with a silt trap.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 16

    Sieve Aperture

    450mm diameter

    sieves (kg)

    Maximum mass 300 mm diameter

    sieves (kg)

    200 mm diameter

    sieves (g)

    50 mm 10 4.5 37.5 8 3.5 28 6 2.5 20 4 2.0 14 3 1.5 10 2 1.0 6.3 1.5 0.75 5 1.0 0.5 3.35 300 2 200 1.18 100 600m 75 425 75 300 50 212 50 150 40 63 25 Table 2.2-3 maximum mass to be retained on each test sieve at the completion of sieving. - Drying

    The whole of the material retained on each sieve is allowed to drain, and is carefully transferred to trays or evaporating dishes. These are placed in an oven to dry at 105-110 C, preferably overnight.

    - Weighing After cooling, the whole of the dried material is put together and weighed to an accuracy of 0.1% (M4).

    - Sieving The dry soil is passed through a nest of the complete range of sieves to cover the sizes of particles present, down to the 6.3 mm sieve. This operation may be carried out by hand or preferably on a sieve shaker, exactly as in the dry sieving procedure. Weigh the amount retained on each sieve to 0.1 % of its total mass. If the fraction passing the 6.3 mm sieve is small, i.e. not more than 150 g, the sample may be sieved by dry sieving on the appropriate sieves down to and including the 63 m test sieve. Weigh the amounts retained on each sieve, and any fines passing the 63 m test sieve (Mf), to 0.1 % of its total mass. If the fraction passing the 6.3 mm sieve is large i.e. substantially greater than 150 g, it should be accurately weighed (M5 ) and then subdivided to give a sample of 100-150 g. Weigh this fraction (M6 ) and then sieve on the appropriate sieves down to and including the 63 m test sieve. Weigh the amounts retained on each sieve, and any fines passing the 63 m test sieve, (Me) If riffling is not necessary, (M6 ) is the same as (M5 ).

    - Weighing The portion retained on each sieve is weighed, each to an accuracy of 0.1%.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 17

    Calculations - Calculation for the particles larger than 20mm in size, calculate the proportion by mass of material

    retained on each of the coarse series of sieves as a percentage of M1 For example:

    Percentage retained on 28 mm sieve = 100M

    mm)28( M

    1

    - Calculate the corrected mass of material retained on each of the sieves between 20 mm and 6.3 mm

    by multiplying by 3

    2

    MM

    , then calculate this mass as a percentage of M1

    For example:

    Percentage retained on 10 mm sieve = M(10 mm)

    13

    2

    M100

    MM

    - Calculate the corrected mass of material retained on each of the sieves finer than the 6.3 mm sieve

    by multiplying by

    3

    2

    6

    5

    MM

    MM

    , then calculate this mass as a percentage of M1

    For example:

    Percentage retained on 300 m sieve = M(300 m)

    13

    2

    6

    5 100MM

    MMM

    - Calculate the cumulatieve percentage by mass of the sample passing each of the sieves from the

    general relationship: (% passing this sieve) = (% passing previous sieve)-(% retained on this sieve) Calculate the fraction passing the 63 m test sieve by difference. The mass of fines lost by washing is equal to (M3-M4). To this is added the mass of any fine material (Mf) passing the 63 m test sieve when dry sieved.

    Percentage passing 63 m sieve = ( ) 100 1

    2

    3

    43

    +MM

    MMMM f

    Reporting In addition to the particle size curve and the usual sample identification data, the sheet should include the visual description of the sample. This should be the description of the sample before testing, and modified as necessary as a result of the additional information revealed by the test result. Any material removed before sieving, such as vegetation or an isolated cobble, should be reported. Tabulated data showing the percentage each sieve are sometimes required instead of, or in addition to, the grading curve.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 18

    2.3 Hydrometer test BS 1377: part 2:1990 Scope of the test The hydrometer analysis is a widely used method to obtain the distribution of particle sizes in the silt range (63-2 m), and the percentage of clay minerals < 2m. The test is usually not performed if less than 10% of the material passes the 63 m sieve. The hydrometer analysis utilises the relationship among the velocity of fall of spheres in a fluid, the diameter of the sphere, the specific weights of the sphere and of the fluid, and of the viscosity of the fluid as expressed by the Stokes law. NOTE: The hydrometer is a very fragile device; it should be handled with care. Never hold it horizontal while holding it on one side, the bulb is very heavy and the glass could break. Hold it on the bulb when moving it horizontal. When moving it in and out of a cylinder, keep it as straight as possible; a small angle could break it. Apparatus used soil hydrometer two 1000 ml glass measuring cylinders, with rubber stops thermometer high speed stirrer sieves 200 mm diameter; 63 m, 212 m, 600 m, 2 mm and a receiver balance readable to 0.01 g drying oven, 105-110 C stopwatch readable to 1 s. steel rule four evaporating dishes 1000 ml beaker two measuring cylinder, 100 ml and 50 ml wash bottle and distilled water constant-temperature bath glass rod: 12 mm diameter, 400 mm long standard dispersant solution: that is 33 g sodium hexametaphosphate and 7 g of sodium carbonate in

    distilled water to make 1 litre solution Calibrations and corrections of hydrometer readings Each density reading taken on the hydrometer must first be expressed as a hydrometer reading, Rh, corresponding to the level of the upper rim of the meniscus. This is done by subtracting 1 from the density and moving the decimal point three places to the right. For example, a density of 1.028 would be a hydrometer reading of Rh = 28. Meniscus correction Insert the hydrometer is a 1 L cylinder containing about 800 ml water. By placing the eye slightly below the plane of surface of the liquid and then raising it slowly until

    the surface seen as an ellipse becomes a straight line, determine the point where the plane intersects the hydrometer scale.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 19

    By placing the eye slightly above the plane of surface of the liquid, determine the point where the plane intersects the hydrometer scale.

    Record the difference between the two readings as the meniscus correction, Cm.

    Rh = Rh + Cm Scale calibration of hydrometer Calculate the effective depth, HR (mm), corresponding to each of the major calibration marks, Rh from the equation:

    += L900VhHH h21R

    where: H = length from the neck of the bulb to graduation Rh h = length of the bulb = 159 mm for B.S. hydrometer Vh = volume of hydrometer bulb = 70 ml for B.S. hydrometer L = distance between the 100 ml and the 1000 ml scale markings of the sedimentation cylinder

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 20

    Example:

    Rh length H Hr mm mm mm h 159 mm N= 16 Vh 72 ml

    25 d1= 19 35 101.78 L 318 mm 20 d2= 38.5 54.5 121.28 15 d3= 58 74 140.78 10 d4= 77 93 159.78 5 d5= 97 113 179.78 0 d6= 117 133 199.78 -5 d7= 137 153 219.78

    Plot the relation between Hr and Rh as a smooth curve, and determine the relation. With this relation, we can calculate for each reading Rh the corresponding Hr.

    scale calibration hydrometer

    y = -3.9286x + 199.71R2 = 0.9999

    0

    50

    100

    150

    200

    250

    -10 0 10 20 30

    Rh

    Hr calibration

    Linear (calibration)

    Sample preparation Dry the sample in an oven at 60-65C. Amount of dry sample

    for sandy soil 100 gram for clayey soil 50 gram

    Weigh the soil to 0.01 gram Place the soil in a 1000 ml beaker If the sample contains organic matter (>0.5%) we have to remove this as follows: Add 150 ml of hydrogen peroxide and stir gently for a few minutes with a glass rod Cover with a cover glass and allow to stand overnight Next morning heat the flask and stir gently, either on a low-heat hot plate or on a low gas flame.

    Agitate frequently by stirring or by shaking with a rotary motion. Frothing over must be avoided. If necessary, add more hydrogen peroxide in increments of about 100 ml until the oxidation process is complete. Very organic soils may require several additions of hydrogen peroxide, and the oxidation process may take 2 or 3 days.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 21

    As soon as frothing has stopped, the volume of liquid is reduced to about 50 ml by boiling which decomposes any excess hydrogen peroxide

    Transfer the contents of the conical flask to a funnel with a Whatman No 50 filter paper, and wash thoroughly with distilled water

    Transfer the residue from the filter paper to container using a fine jet of distilled water from a wash bottle and dry the sample at 60-65C.

    Take the weight mp, weight after pre-treatment. Executing the test Dispersion Add 100 ml of the standard dispersing solution to the soil. Shake the mixture thoroughly until all the soil is in suspension. Transfer the soil with some distilled water to the cup of the high-speed stirrer and stir for about 1

    hour. Transfer the suspension to the 63 m sieve placed on a receiver. Wash the soil in the sieve with a maximum of 500 ml distilled water. Transfer the suspension in the receiver into a 1000 ml sedimentation cylinder, this will be the

    sedimentation cylinder. Transfer the material retained on the 63 m sieve to an evaporating dish and dry it in the oven at

    105 to 110 C. When cooled, sieve this material on the 2mm, 600 m, 212 m and 63 m. Dry and weigh the material retained on each sieve to 0.01 g. Add any material passing the 63 m sieve to the sedimentation cylinder. Sedimentation Fill the sedimentation cylinder to the 1 L graduation mark with distilled water. Place the sedimentation cylinder in the constant-temperature bath, set on 25 C. Place a second cylinder containing 100 ml of the dispersant solution and distilled water to exactly 1

    L. in the constant-temperature bath: this is for calibration readings of the dispersant solution and for storage of the hydrometer between the readings.

    Allow the cylinders to stand in the bath until they have reached the bath temperature (about 1 hour). Insert a rubber stop in the sedimentation cylinder or close it off by hand and shake the cylinder

    vigorously to obtain a uniform suspension. Stir if necessary with a glass rod so that all material goes into suspension. The cylinder is inverted for a few seconds, and is then stood in the constant temperature bath. Without delay as soon as it is in the upright position, the stop-watch is started (zero time).

    Remove the rubber bung and insert the hydrometer steadily and allow it to float freely. It must not be allowed to bulb up and down, or to rotate. However a quick rotational twist with the fingers on the top of the hydrometer will dislodge any air bubbles which may adhere to the side.

    Readings of the hydrometer are taken at the top of the meniscus level at the following times from zero: 0.5 , 1 , 2 , 4 minutes.

    The hydrometer is removed slowly, rinsed in distilled water, and placed in the separate cylinder of distilled water in the constant temperature bath.

    Observe and record the top of the meniscus reading, Ro. Insert the hydrometer for further readings at the following times from zero: 8 , 30 min; 2 ,8, 24

    hours and twice during the following day. It is not essential to keep rigidly these times, provided that the actual time of each reading is recorded. Insert the hydrometer slowly about 15s before a reading is due.

    Insert and withdraw the hydrometer very carefully to avoid disturbing the suspension unnecessarily. Observe and record the temperature of the bath after every recording. If the temperature varies

    more than 1 C another reading to determine Ro should be taken. Use a suitable form to record your observations.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 22

    Calculation Dispersion Calculate the mass percentages according to the wet sieving procedure in paragraph 2.2 Sedimentation Calculate the effective depth Hr Calculate the equivalent particle diameter D (mm), from the equation

    ( ) tHD

    s

    r

    1*005531.0 =

    Where: = dynamic viscosity of water at the test temperature (mPa.s), table 2.3.1 Hr = effective depth (mm) s = particle density (Mg/m3) t = elapsed time (min)

    Calculate the modified hydrometer reading, Rd, from the equation Rd = Rh' - Ro'

    Where: Ro' = hydrometer reading at the upper rim of the meniscus in the dispersant solution

    Calculate the percentage by mass, K, of particles smaller than the corresponding equivalent particle

    diameter , D (mm), from the equation:

    ( ) dss R1m

    100K

    = , where m = mass of dry soil used (g) or mp = mass of soil after pre-treatment.

    s = particle density (Mg/m3)

    Reporting The report shall affirm that the test was carried out in accordance with BS 1377: Part 2: 1990 and shall include the following information: 1. the method of test used 2. the results of the sedimentation analysis 3. the results of the sieve analysis 4. the method of pre-treatment 5. the sieve curve Temperature

    (C) Dynamic viscosity,

    (mPas) 0 1.7865 5 1.5138

    10 1.3037 15 1.1369 20 1.0019 25 0.8909 30 0.7982 40 0.6540

    Table 2.3.1 viscosity of water

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 23

    The Atterberg limits The Atterberg limits are the so-called consistency limits. Determining the Atterberg limits is a very useful method to classify cohesive soils. The concept is based on the fact that the consistency depends largely on its water content. The Atterberg limits comprise the liquid limit (WL), the plastic limit (Wp) and the shrinkage limit (Ws). They define the boundaries between four stages of a soil. Most of the Soil Classification Systems for engineering purpose is, among other parameters, based on the consistency limits (See chapter 1-1). The classification of soils is not the only application of the Atterberg limits. There is also a good correlation with the strength of cohesive soils, expressed in Cu , the undrained shear strength. The consistency limits have been used all over the world for many years and a lot of empirical relationships have been developed. There are four test devices for determination of the liquid limit. These devices are: Casagrande cup, according to the American standard: ASTM, 1995. D 4318 Casagrande cup, according to the British standard: BS 1377: Part 2:1990 Fall cone, according to the British standard: BS 1377: Part 2:1990

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 24

    3.1 Liquid limit with Casagrande cup. BS 1377: Part 2:1990 (ASTM D4318) Scope of the test The liquid limit of soil is the water content, expressed as a percentage of the weight of the oven dried soil, at the boundary between the liquid and the plastic state. The water content at this boundary is arbitrarily defined as the water content at which two halves of a soil cake will flow together for a distance of 12-mm along the bottom of the groove separating the two halves, when the cup is dropped 25 times for a distance of 1 cm at the rate of 2 drops/s. Note: The difference between the American and British Standard, is the difference in base plate of the

    Casagrande cup. The British standard defines a relative soft rubber base, the American standard a harder ebonite one. Because of this difference, the results of the British method are generally higher.

    Apparatus used - Casagrande cup, according the ASTM or BS standard. - Flat glass plate about 500mm square. - Mass balance accurate to 0.01g - Drying oven - Glass cup or tin dishes - Spatulas

    Fig. 3.1.1 Casagrande apparatus Sample preparation Place the soil sample, weighing about 250 g, from the thoroughly mixed portion of the material passing the No.40 (425-m) sieve obtained in accordance with the used standard in a porcelain evaporating dish (about 114-mm in diameter) and thoroughly mix with 15 to 20 ml of distilled water by alternately and repeatedly stirring, kneading, and chopping with a spatula. Mixing can also be done on a glass plate in the case care shut be taken to keep the hole sample at the same moister content. Make further additions of water in increments of 1 to 3 ml. Thoroughly mixes each increment of water with the soil as previously described, before adding another increment of water. Test procedure When sufficient water has been thoroughly mixed with the soil to produce a consistency that will require 30 to 35 lift and drops of the Casagrande cup to cause closure of the groove Place a portion of the mixture in the cup above the spot where the cup Pests on the base. Squeeze it

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 25

    down and spread it in the position shown in fig. 3.1-2. with as few strokes of the spatula as possible, care being taken to prevent the entrapment of air bubbles within the Mass. With the spatula (having a blade about 76-mm in length and 19mm in width) level the soil and at the same time trim it to a depth of 1 cm at the point of maximum thickness. Return the excess soil to the evaporating dish. Divide the soil by firm strokes of the grooving tool along the diameter through the centreline of the cam follower so that a sharp, clean groove of the proper dimensions will be formed. To avoid tearing of the sides of the groove or slipping of the soil cake on the cup, up to six strokes, from front to back or from back to front counting as one stroke, shall be permitted. Each stroke should penetrate a little deeper until the last stroke from the back to front scrapes the bottom of the cup clean. Make the strokes with as few strikes as possible.

    Fig. 3.1.2 Casagrande cup Lift and drop the cup by turning the crank at the rate of 2 revolutions per second, until the two halves of the soil cake come in contact at the bottom of the groove along a distance of about 12 mm. Record the numbers of drops required to close the groove along a distance of about 12-mm. Remove a slice of soil approximately the width of the spatula, extending from edge to edge of the soil cake in right angles to the groove and including that portion of the groove in which the soil flowed together, and place it in a suitable container (for example a matched watch glass). Weigh and record the mass. Oven-dry the soil in the container to constant mass at 110 C and reweigh as soon as it has cooled but before hydroscopic moisture can be absorbed. Record this mass. Record the loss in mass due to drying as the mass of water. Transfer the soil remaining in the cup to the evaporating dish. Wash and dry the cup and grooving tool, and reattach the cup to the carriage in preparation for the next trial. Repeat the foregoing operations for at least two additional trials with the soil collected in the evaporating dish, to which sufficient water has been added to bring the soil to a more fluid condition. Preserve after completion of the test the test sample if the plastic limit and plasticity index test has to be determined from the soil sample. The object of this procedure is to obtain samples of such consistency that the number of drops required closing the groove Will be above and below 25. The number of drops should be less than 35 and exceed 15. The test should always proceed from the dryer to the wetter condition of the soil. Calculation Calculate the water content Wn of the soil, expressed as a percentage of the weight of the oven-dried soil, as follows:

    100soil ovendriedof mass

    waterof mass =Wn

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 26

    Preparation of the flow curve. Plot a "flow curve" representing the relationship between water content and corresponding number of drops of the cup on a semilogarithmic graph with the water content as abscissa on the arithmetical scale, and the numbers of drops as ordinate on the logarithmic scale. The "flow curve" is a straight line drawn as nearly as possible through the three or more plotted points. See fig. 3.1.3

    Fig. 3.1.3

    Reporting -Report the liquid limit as the water content corresponding to the intersection of the flow curve with the 25-drop ordinate as the liquid limit of the soil. Round off this number to the nearest whole value.

    -Treatment of the soil. -The percentage material passes the 425 m sieve, if it was sieved.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 27

    3.2 Liquid limit using the cone penetrometer BS 1377: Part 2:1990 Scope of the test With this test, one can obtain the liquid limit. This value is often used in classification systems, together with particle size analysis. It is based on the measurement of penetration into the soil of a standardised cone of specified mass. At the liquid limit the cone penetration is 20 mm. Note: The results obtained with the cone penetrometer may be differ slightly from those with the Casagrande apparatus, but in most cases up to a liquid limit of 100 these differences will not be significant. Apparatus used - Cone penetrometer with standard cone of mass 80 gr. sees fig 3.2.1 - sample cup of diameter 55 mm and 40 mm deep - Flat glass plate about 500mm square. - 2 spatulas - wash bottle - drying oven - mass balance accurate to 0.01 g -

    Fig.3.2.1 cone penetrometer Sample preparation Wherever possible the test shall be carried out on soil in its natural state. With many clay soils it is practicable and shall be permissible to remove by hand any coarse particles present, i.e. particles retained on a 425m test sieve. Otherwise these particles shall removed by wet sieving.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 28

    Sieve procedure -Take a sample of the soil of sufficient size to give a test specimen weighing at least 300 g. which passes the 425 m test sieve.

    -Take a representative sample and determine its moisture content, Wn (in %) -Weight the remainder of the sample to an accuracy of within 0.01 g (M6) -Place the sample in a container under just enough distilled water to submerge it. -Stir the mixture until it forms a slurry. -Sieve the slurry through the 425 m sieve with the minimum amount of distilled water until the water passing is virtually clear.

    -Collect the material retained on the 425 m sieve, dry it at 105 C and weigh it to an accuracy of within 0.01 g (M7).

    -Collect the fines in a receiver or large container if necessary, and let the fine particles settle. -After a suitable interval pour off any clear water above the suspension, and let it dry (warm air) until it forms a stiff paste.

    Calculation: From the sieved soil calculate the dry mass, Md (in g), of the initial sample from the equation:

    6100

    100 MW

    Mn

    d

    += Where Wn is the moisture content (in %) M6 is the mass of particles retained on 425 m sieve (in g).

    %100P 7a

    =d

    d

    MMM

    Where M7 is the dry mass of particles passing the 425 m sieve (in g) Execution of the test - Thoroughly mix the sample on the glass plate using two spatulas, and if necessary add distilled

    water, to form a plastic material - Place the paste into an airtight container, and leave it standing for a curing period of 24 hour, or

    overnight, to allow water to permeate through the soil mass. For soil of low clay content, such as very silty soils, the curing period may be omitted.

    - Remove the soil from the container and remix with the spatulas for at least 10 min. Some soils (heavy clays) up to 40 min.

    - fill the sample cup with the soil and trim off excess material with the spatula to form a smooth even surface being careful not to trap any air bubbles

    - bring the point of the cone to the surface of the sample lower the dial gauge pointer to the top of the cone and set the gauge on zero

    - release the cone pressing the release button for 5 seconds - lower the pointer to the new position of the cone - Take a reading to the nearest 0.1 mm, it should be approximately 15 mm for the first test. - Lift out the cone and clear it carefully. Add a little more wet soil to the cup and take a second

    reading. If the second cone penetration differs from the first by less than o.5 mm, the - Average value is recorded, and the moister content is measured. If the second penetration is

    between 0.5 and 1 mm different from the first, a third test is carried out, and provided the overall

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 29

    range does not exceed 1mm, the average of the three penetrations is recorded and the moisture content is measured. If the overall range exceed 1mm, the soil is removed from the cup and remixed, and the test is repeated.

    - take a sample of approximately 10 gram from the cup and determine its moisture content - To the remainder of the material add some distilled water and repeat the above procedure. This is

    done at least three more times to get a range (min. 4) of penetration values from about 15mm to 25 mm.

    - N.B. One must be careful not to add too much water at one time. Calculation The moisture contents determined are plotted against the respective penetration depth, both on a linear scale. The liquid limit is defined as that moisture content where the cone penetrates 20 mm into the sample. This value is interpolated from a graph. See fig. 3.2.2. Reporting -The liquid limit is expressed to the nearest whole number. -Treatment of the soil. -The percentage material passes the 425 m sieve, if it was sieved.

    Fig 3.2.2

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 30

    3.3 Plastic limit BS 1377: Part 2:1990 Scope of the test The plastic limit is often used together with the liquid limit to determine the plasticity index which when plotted against the liquid limit on the plasticity chart provides a means of classifying cohesive soils. It is the empirical established moisture content at which soil becomes to dry to be plastic. Apparatus - glass plate - 3 mm diameter metal rod - spatulas - drying oven - mass balance accurate to 0,01 gram. Sample preparation ca. 20 gram of material is needed. The sample may be a disturbed sample. We only use material passing the 425 m sieve. Execution of the test. - Thoroughly knead the sample and if necessary mix with the distilled water for 10 min. to form a

    plastic ball. - Mould the ball between the fingers and roll between the palms of the hands so that the warmth of

    the hands slowly dries it. When slight cracks begin to appear on the surface, divide the ball into two portions each of about 10 g. Further divide each into four equal parts, but keep each set of four parts together.

    - One of the parts if formed into a thread about 6 mm diameter, using the finger and thumb of each hand. The thread must be intact and homogeneous. Using a steady pressure, roll the thread between the fingers of one hand and the surface of the glass plate. The pressure should reduce the diameter of the thread from 6 mm to about 3 mm after between five and ten back-and-forth movements of the hand. Some heavy clay may need more than this because this type of soil tends to become harder near the plastic limit. It is important to maintain a uniform rolling pressure throughout; do not reduce pressure as the thread diameter approaches 3 mm.

    - Mould the soil between the fingers again to dry it further. Form it into a thread and roll out again as before. Repeat this procedure until the thread crumbles when it has been rolled to 3-mm diameter. The metal rod serves as a reference for gauging this diameter. By "crumbling" is meant shearing both longitudinally and transversally as it is rolled. Crumbling must be the result of the decreasing moisture content only, and not due to mechanical breakdown caused by excessive pressure, or oblique rolling or detachment of an excessive length beyond the width of the hand.

    - The first crumbling point is the plastic limit. It may be possible to gather the pieces together after crumbling, to reform a thread and to continue rolling under pressure, but this should not be done.

    - As soon as the crumbling stage is reached, gather the crumbled threads and place them into a weighed moisture content container.

    - Repeat for the other three pieces of soil, and place in the same container. Weigh the container and soil as soon as possible, dry in the oven overnight, cool and weigh dry, as in the standard moisture content procedure.

    - Repeat stages on the other set of four portions of the soil, using a second moisture content container.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 31

    Calculations Calculate the moisture content of the soil in each of the two containers. Take the average of the two results. If they differ by more than 0,5% moisture content, the test should be repeated. Reporting -The average moisture content referred to above is expressed to the nearest whole numbers and reported as the plastic limit.

    -The treatment of the soil. -The percentage of material passes the 425m sieve if it was sieved. Remarks From some soils the plastic limit cannot be determined. Crumbling occurs before you reach 3mm. or rolling of the soil is not possible. Reference Head K.H. (1982): Manual of Soil Laboratory Testing, Vol 1,Pentach Press, London Plymouth.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 32

    4.1 Density BS 1377: Part 2:1990 Scope of the test The bulk density of a soil, , is the mass per unit volume of the soil deposit including any water it contains. The dry density, d, is the mass of dry soil contained in a unit volume. Both are expressed in Mg/m3, which is numerically the same as g/cm3. Three methods are specified. The first applies to soils that can be formed into a regular geometric shape, the volume of which can be calculated from linear measurements. In the second the volume of the specimen is determined by weighing it submerged in water. In the third the volume is measured by displacement of water. Apparatus used: - calliper with accuracy of 0.1mm - balance with accuracy of 0.01g - cutting and trimming tools - Paraffin Linear measurement method This method is suitable for the determination of the density of a sample of cohesive soil of regular shape. The sample is mostly extruded from a sample tube but can also be shaped in a cube or rectangular block from a undisturbed soil sample - The specimen volume is calculated from the average value of several calliper readings (3 at least)

    for each dimension of the sample - Weight the trimmed specimen to an accuracy of 0.1 % (m) - Calculate the volume, V of the specimen. Calculations The bulk density can be calculated:

    = Vm

    If the moisture content, W (in %), of the soil is known, calculate the dry density of the specimen, d (in Mg/m3), from the equation:

    d = W100

    100+

    Express the density and dry density of the soil specimen to the nearest 0.01 Mg/m3 Remark: In practice we often use a (density) cutting ring to prepare a cylindrical sample with a fixed volume Immersion in water method This method determine the bulk density and dry density of samples of natural or compacted soil by measuring its mass in air and its apparent mass when suspended in water.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 33

    - Trim the soil sample, until a specimen is produced measuring at least 100 mm in each dimension. - Weigh the specimen to the nearest 1 g (Ms) - Fill al l the surface air voids of the specimen with a material that is insoluble in water, e.g.

    plasticine or putty and weigh to the nearest 1 g (Mf) - Coat the specimens completely by dipping in molten paraffin wax. Allow the waxed specimen to

    cool and weigh to the nearest 1 g (Mw) - Measure the apparent mass of the specimen while suspended in water to the nearest 1 g (Mg) Calculations Calculate the volume of the specimen, Vs (in cm3), from the equation:

    =

    f-wg-w

    sM

    waterMMV M

    Where, Mw is the mass of specimen and wax coating (in g); Mg is the apparent mass of specimen and wax coating when suspended in water (in g) Mf is the mass of specimen after making up surface voids with filler (in g); is the density of paraffin wax (in g/cm3) Calculate the bulk density of the specimen, (in Mg/m3), from the equation:

    s

    s

    VM=

    Where, Ms is the mass of the soil specimen (in g) Water displacement method This method used the water displacement and mass of a specimen, to calculate the bulk density and dry density. The sample is prepared like the water immersion method and put in a water container with siphon outlet. By taking the weight of the water coming out, the volume can be calculated. Reporting The report shall include the following information: Data on the sample Project name, location, and date of sampling, sample number, depth below terrain (in case of a borehole) Type of sample (core, block or other), sample dimensions The sample transport and storage conditions The density should be reported to the nearest 0.01 Mg/m3 The report should specify the type of test.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 34

    4.2 Natural Moisture Content BS 1377:part 2,1990 Scope of the test The objective of the test is to determine the water content of a soil sample as it was sampled in the field or at the moment of testing for the accurate determination of in-situ water content, the sampling, storage, transporting and handling precautions should be such that the water content remains within 1% of the in-situ value. Apparatus used - balance accurate to 0.01 gr. - sample container (watch glasses or tins) - oven (24 hr at 105C 5C) - dessicator Sample preparation The quantity of the soil sample required for an accurate measurement of the natural water content is dependent upon the particle size of the sample. - fine grained material use 30 g - medium grained material use 300 g - coarse grained material use 3000 g - Execution of the test - weigh the sample container to 0,01 gr. accuracy M1 - add the material to be tested and weigh again M2 - place container with sample in the oven for 24 hours at a controlled temperature of 105 C - cool the sample in the dessicator - weigh the oven dry and cooled sample M3 Calculations

    Moisture content W = %100M1-M3M3-M2

    sample of massdry waterof mass =

    With help of the moisture content W, we can calculate the dry density, with the following calculation:

    Dry density = 100 W100

    insitu mass + Reporting - Data on the sample - Project name, location, date of sampling, sample number, depth below terrain (in case of bore hole) - Type of sample (core, block, disturbed, or other), sample dimensions. - lithology, particle size, density, natural moister content - The sample transport and storage conditions - The water content should be reported to the nearest 0.1%.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 35

    4.3a: Particle density small pyknometer method BS 1377:part 2,1990 Scope of the test The objective of the test is to determine the density of the soil particles finer than 2mm. Apparatus used - Two 50mL density bottles (pyknometers) with stoppers - A rod small enough to go through the neck of the density bottle. - A constant temperature water bath in the range from 20-300C 0.2 0C - A vacuum desiccator - A desiccator containing anhydrous silica gel. - Balance accurate to 0.001 gr. - Oven (24 hr at 105C 5C) - Vacuum system - A wash bottle containing air-free distilled water - A small riffle-box Sample preparation At least two specimens, each between 5g and 10g shall be obtained by riffling. The specimens shall be oven dried at 105C to 110C and stored in an airtight container. Execution of the test - Wash the density bottles, dry, cool and weigh to the nearest 0.001g (m1). - Transfer the soil specimen to the density bottle. Weigh the bottle, with stopper to the nearest 0.001g

    (m2) - Add enough air-free distilled water to cover the soil in the bottle. Place the bottle, without stopper

    in the vacuum desiccator. Reduce the pressure gradually to about 25kPa. Leave the bottle for at least 1 hour under vacuum until no further loss of air is apparent

    - Release the vacuum and remove the desiccator lid. Stir the soil in the bottle. Before removing the stirring rod wash off any soil particles with a few drops of air-free water. Replace the lid of the desiccator and repeat the vacuum procedure as specified before

    - This procedure is repeated until no more air is evolved from the soil. - Remove the density bottle from the desiccator and add more air-free water until full. Insert the

    stopper and immerse the bottle up to the neck in the constant-temperature bath. Leave the bottle in the bath for at least 1 hour so that the bottle attains the temperature of the bath.

    - If there is an apparent decrease in the volume of the liquid, remove the stopper, add more liquid to fill the bottle and replace the stopper. Return the bottle to the bath and again allow the contents to attain the constant temperature..

    - Remove the bottle from the bath and wipe it dry. Weigh the bottle with stopper, soil and water to 0.001g (m3)

    - Clean out each bottle, fill it completely withy de-aerated water, insert the stopper and immerse in the constant temperature bath as before. If necessary fill the bottle as specified before.

    - Take the bottle out of the bath, wipe it dry and weigh it to the nearest 0.001g (m4)

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 36

    Calculations

    Particle density = s 2 14 1 3 2

    m -m(m -m )-(m -m )

    = Where M1 = mass of density bottle M2 = mass of bottle and dry soil M3 = mass of bottle and soil and liquid M4 = mass of bottle and liquid If the result of the two samples differs more than 0.03Mg/m3 the test shall be repeated. Reporting The method of test used The average value of the particle density of the soil specimen to the nearest 0.01 Mg/m3

    4.3b Particle density large pyknometer method BS 1377:part 2,1990 Scope of the test The objective of the test is to determine the density of non-cohesive soil containing particles finer than 20mm. Coarse particles should be broken down. Apparatus used - A pyknometer, a glass vessel of nominal 1L capacity designed for a screw-top lid, fitted the

    following a corrosion-resistant screw ring a conical cap of corrosion-resistant metal with a cone-angle of 75 o to 78o and with a hole 6 0.5mm diameter at its apex

    - A glass about 300mm long and 6mm diameter. - A thermometer range 0C to 50C readable to 1C - Balance accurate to 0.5 gr. - Oven (24 hr at 105C 5C) Sample preparation Take a sample of about 1.5kg. Coarse particles should be broken down. At least two specimens, each of about 400g shall be obtained by riffling. The specimens shall be oven dried at 105C to 110C and stored in an airtight container. Execution of the test - Clean and dry the pyknometer and weigh to the nearest 0.5g (m1). - With the screw top removed transfer the soil specimen into the bottle. Weigh the bottle, with screw-

    top assemble to the nearest 0.5g (m2) - Add water at a temperature of within 2C of the average room temperature to about half fill the

    pyknometer. Stir the mixture thoroughly with the glass rod to remove air trapped in the soil. - Fit the screw cap assembly and tighten so that the reverence marks coincide. Fill the pyknometer

    with water. - Agitate by shaking the pyknometer, or by rolling it on the bench, while holding one finger over the

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 37

    hole in the conical top. Allow air to escape froth to disperse. Leave the pyknometer standing for at least 24h at room temperature constant to within 2C.

    - Top up the pyknometer with water so that the water surface is flush with the hole in the conical cap. - Dry the pyknometer on the outside and weigh the whole to the nearest 0.5g (m3) - Empty the pyknometer, wash it thoroughly and fill it completely with water at room temperature. - Dry the pyknometer on the outside and weigh to the nearest 0.5g (m4) - Repeat the test using the second sample. If the results differ more than 0.05 Mg/m3 repeat the test. Calculations

    Particle density = s 2 14 1 3 2

    m -m(m -m )-(m -m )

    = Where M1 = mass of pyknometer M2 = mass of pyknometer and dry soil M3 = mass of pyknometer and soil and liquid M4 = mass of pyknometer and liquid If the result of the two samples differs more than 0.5Mg/m3 the test shall be repeated. Reporting The method of test used The average value of the particle density of the soil specimen to the nearest 0.5Mg/m3

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 38

    5.1 Vane test BS 1377: Part 7 1990 Scope of the test The vane test is a test, which can be carried out both in the field and in the laboratory. The undrained shear strength of soft to firm cohesive soils can be determined without the sample being disturbed by preparation. This method may be used when the sample is too sensitive or soft to enable a compression test. Apparatus used -Laboratory vane test apparatus see fig 5.1-1 Sample preparation An undisturbed sample should be cut and trimmed to a diameter of 37.5mm with a length of about 75mm. Place the trimmed sample centrally into the sample container belonging to the equipment. Fill the annular space between the wall of the container and the sample with molten wax. Alternatively we can clamp a sample container with an undisturbed sample on the base plate of the vane equipment the sample shut be of sufficient dimensions such that the shearing force applied by the vane is not hampered or influenced by forces originating from the extremities of the sample. Three tests on one sample material should be sufficient if the results are reasonably constant. Execution of the test (for numbers see fig. 5.1-1) Peek value - a choice of spring is made dependent upon the stiffness of the ground : weak ground: spring 2kg.cm firm ground: spring 8kg.cm - measure the dimensions of the vane - clamp the sample container in the clamping attachment or in a other way vertically below the vane

    shaft - Lower the vane gradually without disturbing the soil sample so that the top of the vane is at least

    10mm below the surface of the sample. - bring the maximum pointer in contact with the (strain)angle indicator - note the reading on the circular graduated scale - operate the torque applicator handle with a rate of 1 revolution per second or used the motorized

    drive unit until the maximum shear resistance of the soil is reached. At this point failure occurs and the torque decrease but the maximum pointer remains in the position indicated the maximum angular deflection of the spring. Warning: If the (strain)angle indicator rotate for more then 180 degrees stop the test and repeat with a stiffer spring.

    - record the reading of the maximum pointer as the peek value. Remoulded value - after reading of the (strain)angle indicator rotate the vane rapidly two complete revolutions, to

    remould the soil. - After stopping rotation wait for a few seconds and slowly apply torque as been done for the peek

    strength . - Record the reading of the maximum pointer as the remoulded value Repeat the test at least twice.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 39

    Calculation Calculate the difference between the initial reading and the reading at the peek and remoulded value This difference gives the angle of torque of the spring. Multiply the outcome by the spring factor (is indicated on the spring) and dived the outcome by 180 this give the torque in kgf.cm recalculate this value in N.mm. Average the values obtaining for the different test. If one result differs appreciably from the others (more then 20%) it should be discarded. Calculate the vane shear strength of the soil, v in kPa

    1000*KM

    v = M= measured torque in N.mm K = constant which depends on the dimensions of the vane.

    +=62

    2 DHDK D = vane diameter (mm) H = vane height (mm) Reporting -The average undisturbed and remoulded shear strengths in KPa -The highest and lowest measured values -Type of testing machine -Size of the vane -Indicate the horizon at with the test was executed

    Fig. 5.1.1 Laboratory vane apparatus used at DGM

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 40

    5.2 Shear strength with Triaxial test BS 1377: part 8 1990 Scope of the test: The measurement of the effective shear strength parameters for cylindrical specimens of saturated soil which have been subjected to isotropic consolidation and then sheared in compression, under a constant confining pressure, by increasing the axial strain. The test maybe performed consolidated or unconsolidated under drained or undrained conditions, with the possibility of measuring pore pressure and volume change.

    Overview test set-up The triaxial test set up maintenance the following apparatus (fig 5.2.1) 1- Triaxial test frame controls. 2- Pressure controller air regulator 3- Control panel controls. 4- Triaxial cell controls 5- Load ring controls. 6- Strain transducer Strain transducer max. 25 mm 0.01mm. 7- Pressure transducer Pore pressure transmitter. 8- Volume change apparatus controls 9- Bladders controls air-water cylinder.

    Fig. 5.2.1

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 41

    Description of test The sample is enclosed in a thin rubber membrane, which is sealed against the pedestal and the top cap on the sample by rubber O-rings. The sample is placed on the base plate of a triaxial cell. The removable cap of the cell is placed over the sample and the total triaxial cell is placed in the triaxial frame. The cell can be filled with (de-aired) water, and with the air regulator we can established the desired cell pressure (3). A piston, movable with little friction through a bush in the top cap of the triaxial cell, rest on the top cap of the sample. The upper end of the piston touches a dynamometer, consisting of a metal ring and a dial gauge, which measures the decrease in vertical diameter when a force is applied to the ring. The force is found by multiplying the dial gauge reading by a calibration constant. (See calibration chart) The triaxial frame has a stepper motor and screw jack assembly, which can provide a constant platen speed. This causes a compression of both dynamometer and sample. The rate at which the sample is compressed is depending on the kind test (CU, UU, or CD), and type of material to be tested. A dial gauge just below the dynamometer measures the settlement of the sample. With a pressure transducer, the pore pressure can be measured. And with the automatic volume change apparatus, we can measure the amount of water going in or out the sample. During the practical we will execute an unconsolidated undrained test (UU), this is a normally not much performed test. (No effective stresses are measured) Sample preparation Specimens shall have a height equal to about twice the diameter, with plane ends normal to the axis. The diameter is normally between 35 and 100 mm. Undisturbed specimens shall be prepared with the minimum change of the soil structure and moisture content. The method of preparation shall depend on whether the sample received in the laboratory is contained in a tube of the same internal diameter as the specimen to be tested, or in a tube of larger diameter, or as a block sample. Preparing the sample from a block sample. Cut out an approximately rectangular prism of soil slightly larger than the final dimensions of the specimen. Make the ends of the prism plane and parallel. Put the prism in a soil lathe (fig 5.2.2) and cut off the excess soil in thin layers. Rotate the specimen between each cut until a cylindrical specimen is produced. Take care to avoid disturbance due to torsion effects. Remove the sample from the soil lathe. Cut to the required length and make the ends plane and normal to the specimen axis to within . A handy way to establish this is by putting the sample in a catch tube, and cutting away the surplus. With the aid of the levelling ring (fig.5.2.4), smooth the ends of the sample by placing the ring on the end of the catch tube and giving the ring a few turns. Do this to both ends of the sample and make sure that the sample does not slide up and down in the catch tube.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 42

    Fig. 5.2.2, Soil lathe Preparing the sample from sample tube. (See fig. 5.2.3)

    - Push the sample tube into the block sample; be sure the sample is long enough. - Place the sample tube in the extruder - Put on the inner side off catch tube mineral oil or silicone crease -

    1 = Extruder 2 = Sample tube 3 = Catch tube Fig. 5.2.3

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 43

    - Fasten the catch tube with the fastening fork to the outside of the extruder - By turning the screw of the extruder, press the sample out of the sample tube into the catch tube. - Separate the sample in the catch tube from the remainder in the sample tube with help of a thread

    saw - With the aid of the levelling ring (fig.5.2.4), smooth the ends of the sample. - Placing the ring on the end of the catch tube and giving the ring a few turns - Do this to both ends of the sample and make sure that the sample does not slide up and down in the

    catch tube. -

    1= Catch tube 2= Sample trimmer 3= Porous discs 4= Specimen

    Fig 5.2.4, Catch tube and sample trimmer. - Take the weight from sample with catch tube, by subtracting the weight of the catch tube we can

    calculate the bulk density (fill in your test form). - Place footcap and topcap on the ends of the sample. - Remove the sample carefully out the catch tube - Measure the height and diameter of the sample. (Fill in your test form). Test Procedure The procedure describes the test set up for an unconsolidated undrained test In order to obtain a reasonable assessment of the C and values, three experiments should be done on three different undisturbed samples of the same soil at three different cell pressures. - Place the sample with the foot piece and cap on the base of the pressure cell - Place a membrane inside the membrane application tube and fold the ends over the outside of the

    tube, to fit the membrane snugly against the inside wall of the tube wall suck on the hose to create a vacuum between tube and membrane

    - Slide the membrane application carefully over the sample (see fig. 5.2-4)

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 44

    1 = Membrane application 2 = Sucking tube 3 = Membrane 4 = Base pedestal of the pressure cell 5 = Pressure cap

    Fig.5.2-4 - Remove the suction (vacuum) between the tube and membrane - Roll the membrane ends off of the application tube onto the footpiece and cap - Seal the membrane to the base pedestal using two rubber O-rings - Remove air pockets from between the membrane and the specimen by light stroking upwards - Seal the membrane to the pressure cap with two rubber O rings - Roll the extra membrane back over the rubber ring - Place the cap of the pressure cell over the sample and onto the base plate and fasten it securely with

    the tie rods - Press the piston carefully onto the cap making sure that the piston falls into the circular hole in the

    sample cap - Bring the load plate from the triaxial frame up (see the operation instructions from the triaxial

    Apparatus), until the piston is into contact with the dynamometer (no vertical pressure is exerted on the sample)

    - Open the air vent on the cap off the cell and fill the cell with de-aired water - Close the vent tightly - Build up the desired pressure in the cell with the air regulator cell pressure and control panel (see

    the operation instruction of these apparatus) - Bring the strain gauge in contact with the datum bar on the top of the cell and adjust to read zero - Adjust the dynamometer to read zero - Select the machine speed. - Start the test and note values of the dial gauge from the dynamometer at certain strain intervals see

    test form - Continue the test until a constant reading is obtained on the dynamometer or at 20% strain - Stop the test and remove the pressure from the cell, with help from the air regulator cell pressure. - Bring down the base plate from the triaxial machine - Open the air vent and drain the water out the cell

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 45

    - Remove the sample from the cell and sketch the failure pattern - Determine water content Reporting After executed at least 3 test with different cell pressure (3), we can calculated the deviator stress (1-3)m (in kPa), given by

    P/As 1000 in kPa

    P = is the axial force in N, dial gauge reading times calibration factor (note: the dial gauge reading is already corrected for the applied cell pressure (3) and friction from the piston). As = area cross section of the specimen, this area will change during the compression stage so we need to make a correction: The corrected area is given for each strain reading on the test form.

    Graphically plot the values of deviator stress against the displacement (in percentage) Calculated the major principal stress 1 (in kPa), given by

    1=(1-3) + 3 where

    3 is the cell pressure (kPa) Graphically plot the values 1 and 3 on the horizontal axis. Draw the Mohrs circles and measures the values for the internal angle off friction () and cohesion (c). Calibration chart for load measuring ring 2.0 kN compression. Temperature at calibration 20 C ring serial number 00010105

    Gauge reading 0.001 mm Load kN 245 0.2 481 0.4 725 0.6 965 0.8

    1214 1.0 1459 1.2 1705 1.4 1955 1.6 2201 1.8 2449 2.0

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 46

    5.3 Direct shear test BS 1377: part 7 1990 Scope of the test The direct shear test is used to measure shear strength, friction angle and cohesion of soils for stability analysis of foundation, slopes, and retaining walls. The test may take place under drained, undrained or consolidated-undrained conditions.

    Fig 5.3-1 1-Frame EL 28-007 2-Thyristor controlled drive unit 3-Gear box 4-Load ring 5-Weight hanger 6-Lever arm (beam) with counter balance 7-Displacement transducer 8-Loading yoke During the practical we will execute the unconsolidated undrained test! Description of test The direct shear test is used to determine the shear strength of soils on predetermined failure surfaces. The principle of the direct shear test is illustrated in Fig, 5.3.2. The soil sample confined inside the upper and lower rigid boxes is subjected to the normal load N. This load is applied by the yoke which is placed on the loading cap and by putting weight on the hanger the specimen is loaded axially. Because of the length of the beam the applied weight has to multiply with a factor 11.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 47

    Fig 5.3.2 The shear force T shears the sample; this force is applied by the motorised drive unit and measured with help of the load ring. If A is the area of surface CD, the shear stress acting on surface CD is equal to T/A, and the normal stress is equal to N/A. The soil shear strength is the shear stress that causes the soil to slip on surface CD. It can be defined by Mohr-Coulomb theory: = C + tan Where c is the cohesion and is the friction angle. During the test, the stress state is not completely defined: and are only measured on the horizontal surface, but are undetermined on other surfaces. Therefore, the stress path during direct shear cannot be represented. However, the Mohr circle can be drawn at failure, assuming that the failure plane is horizontal and the stress state is uniform. Sample preparation Specimens of either cohesive or non-cohesive soil may be tested in the shear box. Preparation procedures depend on the type of soil. The size of the largest particle shall not exceed one-tenth of the height of the specimen. Loss or gain of moisture by the sample shall be avoided at all stages of preparation. Normally three similar specimens are prepared, for testing under three different normal pressures Preparation of specimen of undisturbed cohesive soil, 10102 cm (other sizes are possible). - Place the bottom plate. - Place the lower porous plate. - Determine the weight of the sample cutter - Push the sample cutter in the soil sample; trim it with the wire saw and spatula. - Weight the specimen in the cutter to 0.1 g, and calculate the initial mass (Mo ) of the specimen. - Push the specimen out of the cutter and into the shear box keeping its upper face horizontal, until it

    is bedded on to the lower porous plate. Preparation of specimen of cohesion less soil. The procedure depends on whether the soil is dry and can be poured, or damp and needs to be tamped, or saturated. The sample shall not contain a significant amount of material passing a 63 m test sieve, to avoid segregation of fine particles, and is therefore referred to as sand.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 48

    Dry sand: - Determine the depth from the top surface of the upper half to the top of the base plate (h1). - Determine the combined thickness of plates to be used for the test (tp). - Prepare a quantity of soil somewhat larger than required and determined its mass to 0.1 g. - Place the bottom plate. - Place the lower grooved plate. - Place or pour the sand directly into the assembled shear box until the appropriate thickness. - Level the surface - Place the upper grooved plate firmly on the specimen. - Measure the distance from the top of the shearbox to the surface of the grooved plate. (h2). - Weight the total of the unused soil, and determined the initial mass of the specimen (mo). Saturated sand: - Determine the depth from the top surface of the upper half to the top of the base plate (h1). - Determine the combined thickness of plates to be used for the test (tp). - Place the bottom plate. - Place the lower porous plate. - Place the grooved plate. - Prepare a quantity of soil somewhat larger than required and determined its mass to 0.1 g. - Boil the sand in water for 10 minutes - Place the saturated sand into the shearbox and compact it by vibration to achieve the desired

    density. - Place the upper grooved plate firmly on the specimen. - Place the upper porous plate. - Measure the distance from the top of the shearbox to the surface of the porous plate (h2). - Collect all surplus sand, dry and weight it, and determine the dry mass of the specimen (mo) by difference. - Execution of the test Place the shear box in the sleigh. - Fill the shear box from the bottom up with: (see fig 5.3.3) - Bottom plate - Porous drainage plate - Grooved plate (grooves up, at right angles to shear motion) - Sample, (with help of the wooden push block) - Grooved plate (grooves down, at right angles to shear motion) - Porous drainage plate - Top plate with ball bearing N.B. In the case of drained experiments use the grooved plates with the holes.

    Geotechnical Laboratory of DGM, Thimphu Bhutan

  • 14/06/2005 Soil mechanics laboratory manual 49

    Fig 5.3.3 - Apply the normal force by placing the load hanger on the ball bearing. The force is applied by

    placing the slotted weights on the bottom of the hanger. For greater normal forces the slotted weights can put on the hanger from the lever arm. (see fig 5.3-1)

    - Select the shearing speed, for sand a rate of 1 mm/min, for sand the effect of the displacement rate on the friction angle is generally negligible within the range 3 to 0.1 mm/min.