brochure - ica12-50jpl

2
RADIO FREQUENCY SYSTEMS The Clear Choice ® WIRELESS | MOBILE RADIO | MICROWAVE | IN-TUNNEL | IN-BUILDING | TV & RADIO | HF & DEFENSE RFS Plenum-Rated Cables RFS ClearFill ® Line plenum-rated wideband cable with outstanding electrical performance supports all wireless in-building applications RFS delivers a cost-effective, in-building solution with its plenum-rated air-dielectric coaxial cable, the backbone of the ClearFill® Line of products. CATVP-rated, with low flame- spread and low-smoke characteristics, it is ideal for use within the building plenum defined as the "environmental air handling space." This permits use of the cable as part of an in-building Distributed Antenna System (DAS). Plenum-rated cables, tested in accordance with the National Fire Protection Agency (NFPA) testing method 262, have the most stringent flame-retardant and smoke-suppressant characteristics. Due to their low attenuation, outstanding heat transfer properties, and temperature-stabilized dielectric materials, RFS plenum- rated cables provide a safe, long-term operating life at high- transmit power levels. Supports Multiple RF Signals Complete Shielding The solid outer conductor of ClearFill ® Line coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. Outstanding Intermodulation Performance RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory. Wide Range of Applications Typical areas of application are: feedlines for plenum-space installations within occupied buildings or structures. Exclusive Features In-Building Cable Solutions Supporting Technologies LMR (Land Mobile Radio): 450-512MHz Public Safety: 764-776MHz, 806-824/851-869MHz, 4400-5000MHz 700MHz LTE: 698-896 MHz Cellular: 824-896MHz Paging: 929-932MHz PCS/AWS (Advanced Wireless Services): 1710-2155MHz WiFi (Wireless Fidelity): 2300-2500MHz WiMax (Worldwide Interoperability for Microwave Access): 5100-5900MHz WMTS (Wireless Medical Telemetry): 608-614MHz, 1395-1400MHz, 1429-1432MHz Outstanding electrical performance virtually eliminates intermods ICA12-50JPL - 1/2” Diameter - Wideband - UV & CATVP Rated

Upload: cciproducts

Post on 28-Apr-2015

54 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Brochure - ICA12-50JPL

RADIO FREQUENCY SYSTEMST h e C l e a r C h o i c e ®

W I R E L E S S | MOB I L E R AD I O | M I C ROWAV E | I N - T UNN E L | I N - B U I L D I NG | T V & R AD I O | H F & D E F E N S E

RFS Plenum-Rated CablesRFS ClearFill®Line plenum-rated wideband cable with outstandingelectrical performance supports all wireless in-building applications

RFS delivers a cost-effective, in-building solution with itsplenum-rated air-dielectric coaxial cable, the backbone of theClearFill® Line of products. CATVP-rated, with low flame-spread and low-smoke characteristics, it is ideal for use withinthe building plenum defined as the "environmental airhandling space." This permits use of the cable as part of anin-building Distributed Antenna System (DAS). Plenum-ratedcables, tested in accordance with the National Fire ProtectionAgency (NFPA) testing method 262, have the most stringentflame-retardant and smoke-suppressant characteristics. Due totheir low attenuation, outstanding heat transfer properties,and temperature-stabilized dielectric materials, RFS plenum-rated cables provide a safe, long-term operating life at high-transmit power levels.

• Supports Multiple RF Signals

• Complete ShieldingThe solid outer conductor of ClearFill®Line coaxial cable creates a continuous RFI/EMI shieldthat minimizes system interference.

• Outstanding Intermodulation PerformanceRFS coaxial cable's solid inner and outerconductors virtually eliminate intermods.Intermodulation performance is also confirmedwith state-of-the-art equipment at the RFS factory.

• Wide Range of ApplicationsTypical areas of application are: feedlines forplenum-space installations within occupiedbuildings or structures.

Exclusive Features

In-Building Cable SolutionsSupporting Technologies

LMR (Land Mobile Radio): 450-512MHz

Public Safety: 764-776MHz, 806-824/851-869MHz, 4400-5000MHz

700MHz LTE: 698-896 MHz

Cellular: 824-896MHz

Paging:929-932MHz

PCS/AWS (Advanced Wireless Services):1710-2155MHz

WiFi (Wireless Fidelity):2300-2500MHz

WiMax (Worldwide Interoperability for MicrowaveAccess):5100-5900MHz

WMTS (Wireless Medical Telemetry): 608-614MHz, 1395-1400MHz, 1429-1432MHz

Outstanding electrical performancevirtually eliminates intermods

ICA12-50JPL - 1/2” Diameter - Wideband - UV & CATVP Rated

Page 2: Brochure - ICA12-50JPL

RFS Plenum-Rated CablesRFS ClearFill®Line plenum-rated wideband cable with outstandingelectrical performance supports all wireless in-building applications

Product Specifications Model Number ICA12-50JPL

Size 1/2"

Jacket Plenum

Maximum Return Loss, dB (VSWR) 18 (1.228:1) - in the specified bands

Impedance, Ohm 50 +/- 1

Maximum Frequency, GHz 6

Velocity, percent 91

Peak Power Rating, kW 21.4

Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft) 1.48 (0.45)

Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft) 1.90 (0.58)

RF Peak Voltage, Volts 1500

Jacket Spark, Volt RMS 8000

Capacitance, pF/m (pF/ft) 76 (23.2)

Inductance, µH/m (µH/ft) 0.191 (0.058)

Outer Conductor Material Annularly Corrugated Copper

Inner Conductor Material Copper-Clad Aluminum Wire

Diameter over Jacket Nominal, mm (in) 15.93 (0.627)

Diameter Outer Conductor, mm (in) 13.8 (0.54)

Diameter Inner Conductor, mm (in) 4.8 (0.19)

Minimum Bending Radius, Single Bend, mm (in) 120 (4.8)

Minimum Bending Radius, Repeated Bends, mm (in) 254 (10)

Cable Weight, kg/m (lb/ft) 0.4 (0.27)

Tensile Strength, N (lb) 1112 (250)

Recommended / Maximum Clamp Spacing, m (ft) 0.5 / 0.9 ( 1.8 / 3.0 )

Installation Temperature, °C(°F) -15 to +60 (+5 to +140)

Storage Temperature, °C (°F) -15 to +85 (+5 to +185)

Operation Temperature, °C(°F) -15 to +85 (+5 to +185)

Flame Retardant Jacket Specifications Meets/Exceeds Steiner Tunnel Test Method UL 910,

NEC 820-53 (a) CATVP, NFPA-262.

Model Cable Sealing Conductor Attachment Trim Tool Number Type, Size Description Code Inner Outer Series

NF-LCF12-B32 ICA/LCF/HCA/RHCA, 1/2” N Female O-Ring Basket Spring Finger TRIM-Series-ANM-LCF12-B32 ICA/LCF/HCA/RHCA, 1/2” N Male O-Ring Basket Spring Finger TRIM-Series-A

Connectors