BREAST CANCER | CLINICAL ADVANTAGES
BREAST CANCER | CLINICAL ADVANTAGES
Dose (GY)Vo
lum
e (%
)
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 5055
Lung L
Heart
Homeros
Breast R
Spinal Cord
Lung Tot
Body
Dose (GY)
Volu
me
(%)
100
90
80
70
60
50
40
30
20
10
0 5 10 15 2520 30 35
PTV Partial Breast
Rt Lung
Lt Lung
Heart
Rt Breast
Conformal, Homogeneous
CoverageBreast conserving
approach to whole right
breast radiotherapy
TomoDirect™
2 angles, 3DCRTTomoEDGE™
5 cm Dynamic JawsTreatment Planning Time
10 min.Beam-on-time
1.6 min.
TomoDirect™
4 angles, IMRTTomoEDGE™
5 cm Dynamic JawsTreatment Planning Time
20 min.Beam-on-time
2.6 min.
Improved Patient
ConvenienceAccelerated
partial breast
irradiation of the
left breast,
prone position
60.40
54.00
47.26
45.36
40.32
30.24
25.20
15.12
40.50
38.00
36.10
30.40
22.80
19.00
11.40
25 FRACTIONS, 50 Gy
10 FRACTIONS, 38 Gy
Treatment planning examples for a range of different breast radiotherapy indications. Treatment plans developed by Accuray
|
Reduced Margins and Accurate Patient Set-UpThe Radixact and TomoTherapy Treatment Delivery Systems provide the option of efficiently acquiring a CT image before each treatment. A very low dose (typically 1-2 cGy) is delivered per image. With practical daily imaging, planners gain the confidence necessary to reduce margins and therapists can assure accurate patient set-up throughout the course of treatment.
The Radixact™ and TomoTherapy® Treatment Delivery
Systems provide the flexibility to adapt radiation therapy
to any breast cancer patient’s anatomy, delivering
optimal coverage to the target volumes with minimized
cardiac dose and organ-at-risk exposure.
Treatment planning examples for a range of different breast radiotherapy indications. Treatment plans developed by Accuray
|
Dose (GY)
Volu
me
(%)
100
90
80
70
60
50
40
30
20
10
0 10 20 30 5040 6063
PTV 44
Boost
Mediatinum
CTV 44
Lung R
Lung L
Heart
Homeros
Breast R
Spinal Cord
Lung Tot
Dose (GY)
Volu
me
(%)
100
90
80
70
60
50
40
30
20
10
0 10 20 30 5040 6062
PTV_Chestwall
PTV_ScarBoost
PTV_Nodes
Right Lung
Left Lung
Heart
Spinal Cord
Esophagus
LD_Lungs
PostLat Avoid
Liver
Upper Mediast
Throat Avoid
TomoHelical™ IMRT
TomoEDGE™
5 cm Dynamic JawsTreatment Planning Time
40 min.Beam-on-Time
3.4 min.
TomoHelical™
IMRTTomoEDGE™
5 cm Dynamic JawsTreatment Planning Time
45 min. Beam-on time:
5 min.
Simultaneous Integrated Boost
Left breast treatment
with low cardiac dose
and simultaneous
integrated boost
64.00
60.00
55.00
50.00
47.50
40.00
25.00
25 FRACTIONS, 50 Gy
WHOLE BREAST, 60 Gy
(BOOST)
28 FRACTIONS, 50.4 Gy (CHEST WALL),
50.4 Gy (SUPRACLAVICULAR
NODES)
Complex and Long Volumes in One Delivery
Post-mastectomy irradiation of bilateral
chest wall and nodes with a single plan
BREAST CANCER | CLINICAL ADVANTAGES
© 2017 Accuray Incorporated. All Rights Reserved.
Important Safety Information Most side effects of radiotherapy, including radiotherapy delivered with Accuray systems, are mild and temporary, often involving fatigue, nausea, and skin irritation. Side effects can be severe, however, leading to pain, alterations in normal body functions (for example, urinary or salivary function), deterioration of quality of life, permanent injury, and even death. Side effects can occur during or shortly after radiation treatment or in the months and years following radiation. The nature and severity of side effects depend on many factors, including the size and location of the treated tumor, the treatment technique (for example, the radiation dose), and the patient’s general medical condition, to name a few. For more details about the side effects of your radiation therapy, and to see if treatment with an Accuray product is right for you, ask your doctor.
UNITED STATES
Accuray Corporate Headquarters 1310 Chesapeake TerraceSunnyvale, CA 94089 USATel: +1.408.716.4600Toll Free: 1.888.522.3740Fax: +1.408.716.4601Email: [email protected]
Accuray Incorporated1240 Deming WayMadison, WI 53717 USATel: +1 608.824.2800Fax: +1 608.824.2996
ASIA
Accuray Japan K.K.Shin Otemachi Building 7F2-2-1 Otemachi, Chiyoda-kuTokyo 100-0004JapanTel: +81.3.6265.1526Fax: +81.3.3272.6166
Accuray Asia Ltd.Suites 1702 - 1704, Tower 6The Gateway, Harbour City9 Canton Road, T.S.T. Hong KongTel: +852.2247.8688Fax: +852.2175.5799
Accuray Accelerator Technology #39 Huatai Road, Longtan Industrial Zone,Section 2 East, 3rd Ring Road, Chengdu, Sichuan 610051People's Republic of China
EUROPE
Accuray International SarlRoute de la Longeraie 9 (3rd floor)CH – 1110 MorgesSwitzerlandTel: +41.21.545.9500Fax: +41.21.545.9501
| BREAST CANCER | CLINICAL ADVANTAGES