VersaPOD® Data Center Cabinets
WWW.SIEMON.COM
-
8/18/2019 brc_versapod
2/20
1
IT IS ALL ABOUT USING
YOUR SPACE WISELY
Physical space is one of the most important con-
siderations in the data center infrastructure.
How will you fit everything you need today?
What happens when you have more to add
tomorrow?
As equipment density grows, so does the volume
of data and power cables in your cabinets.
You need a way to accomodate this growth anddo it in a way you can efficiently manage.
-
8/18/2019 brc_versapod
3/20
2
You can’t fully populate a cabinet with equipment if you can’t realistically
fit and manage the necessary cabling.
In traditional cabinet designs, space and cable management is often a
limiting factor.
Short of expanding your data center and adding more partially utilized
cabinets, what is the solution?
MAKING SPACE. . .
BY CONVERTING “WASTED” VERTICAL SPACE
Siemon's VersaPOD cabinet system enables a completely new and
efficient approach to your physical data center infrastructure.
By leveraging the vertical space between bayed cabinets and at the end of
row for Zero-U patching, cable management and power distribution,
VersaPOD frees critical horizontal equipment mounting space for equipment
and provides a dedicated, high capacity and easily managed cabling zone.
-
8/18/2019 brc_versapod
4/20
3
Zero-U Cable
Management
VERTICAL C ABLE MA NA GEMENT TRAYS
Installed between bayed cabinets, these
vertical managers help secure and route high
cable-counts, converting internal vertical space
into a large-volume cable management zone.
Trays also contain airflow within each bayed
cabinet.
CABLE MANAGEMENT FINGERS
Vertical 6-inch cable management fingers can
be mounted alongside each Zero-Uvertical space to facilitate routing of cords
between equipment and patching fields as
well as cabinet to cabinet connections.
Optional hinged covers snap onto the cable
management fingers to conceal and protect
cable pathway for improved aesthetics.
CABLE ACCESS POINTS
Multiple openings in the lid allow efficient cable
routing access. An open floor design enables
a high-capacity pathway for under-floor
conveyance configurations.
DEDICATED CABLING PATHWAYS
Creating nearly 178mm (7 in.) of width between
bayed cabinets and 150mm (6 in.) between
equipment mounting rails and doors at the
front and rear, the VersaPOD recessed cornerpost design creates accessible, high-capacity
vertical and horizontal cabling pathways –
eliminating cable routing constraints associ-
ated with standard cabinet designs.
-
8/18/2019 brc_versapod
5/20
4
Zero-U Cable Management Benefits
Getting cable out of the cabinet’s heavily congested
equipment mounting space and into high-capacity vertical
cabling zones drives benefits across your data center
infrastructure.
DENSITY - VersaPOD’s extra vertical space gives you the
room to deploy ultra high-density data center infrastruc-
tures without sacrificing proper cable management and
the overall neatness and aesthetics of the facility.
SCALABILITY - The high capacity of VersaPOD’s
Zero-U cable management zones not only leave significant
space to add cabling channels as your needs grow, it frees
space needed to mount future networking equipment with-
out the need to add more cabinets and consume valuable
data center floor space.
FLEXIBILITY - VersaPOD’s wide variety of cable routing
options enable it to support nearly any data center config-
uration, giving you the flexibility to design an infrastructure
to fit your needs instead of working around the space lim-
itations of traditional cabinets.
ACCESSIBILITY - With your cabling channels in their owndedicated space between the cabinets, you can perform
ongoing moves adds and changes and gain unobstructed
access to your equipment - less time in the cabinets and
more on your strategic goals.
ZERO-U VERTICAL CABLE
MANAGEMENT CHANNELS
Feature an array of integrated cable management
options to offer a high capacity, easily
accessible and concealable pathway for cable
routing and slack management, without consum-
ing or obstructing access to critical equipment
space. Eliminates the need for obstructive, diffi-
cult to maintain cable management add-ons such
as equipment-mounted swing-arms.
END-OF-ROW CABLE MANA GERS
Mount vertically between the cabinet’s
corner posts and side panels to provide
additional Zero-U cable management
zones at each end-of-row or stand-alone
cabinets.
-
8/18/2019 brc_versapod
6/20
5
Zero-U Patching
DUAL-HINGED SPLIT DOORS
Rear split doors can be hinged open in both
directions or removed, providing direct and
unimpeded access to either the vertical
patching zones or equipment areas.
RECESSED CORNER POSTS
150mm (6 in.) of space between equipment
ports and cabinet doors enables cables to be
routed directly from Zero-U patch panels,
cable managers or PDUs to equipment mount-
ing areas. Also facilitates horizontal cabinet-
to-cabinet cable routing and patching.
ZERO-U VERTICAL PATCH PANELS
Vertical copper and fiber patch panels pro-
vide up to 24U of Zero-U vertical patching
space between every two cabinets
(12U front, 12U rear) - up to 1152 copper
and 1728 fiber ports.
These panels conveniently slide forward
providing access to the connections at the
rear of the panel.
-
8/18/2019 brc_versapod
7/20
6
HIGH-CAPACITY HORIZONTAL
CABLE MANAGERS
2U and 4U horizontal managersare available with 100mm (4 in.) or
150mm (6 in.) depths to effec-
tively create horizontal cable
management pathways across a
row of cabinets for cabinet-to-
cabinet cable routing and patch-
ing while hinged covers conceal
and protect the cable pathway.
END-OF-ROW VERTICAL PATCH PANELS
Mount up to 8U of (4U front, 4U rear) patch
panels in the Zero-U vertical space at both
ends of each row.
Zero-U Patching Benefits
SHORTER CORDS AND JUMPERS - Zero-U patch
panels put patching ports right beside equipment ports
- reducing the need for more expensive, longer cords.
Shorter cords with less cable slack improves air flow,
aesthetics and simplifies channel tracing.
MORE DESIGN OPTIONS - With your patching fields
maintained in VersaPOD’s Zero-U vertical space, you
can decrease or even eliminate the use of patch panels
in traditional 19” horizontal mounting space freeing this
space for additional networking and storage equipment
options.
SCALABILITY - Supporting up to 1152 copper and
1728 fiber patching ports between every 2 cabinets
and at both ends of each row, VersaPOD provides
ample patching capacity for future expansion - without
labor-intensive re-design or additional cabinets.
-
8/18/2019 brc_versapod
8/20
7
With energy costs continuing to rise, Siemon’s
VersaPOD system has been designed to control
air flow to maximize thermal management and
efficiency without sacrificing equipment and
cabling density.
EFFICIENCY & THERMAL MANAGEMENT
VERTICAL EXHAUST DUCT (Chimney)
Passively directs the hot exhaust heat from ac-
tive equipment vertically into the return air
space to increase HVAC efficiency. Can be
field extended to a range of ceiling heights.
PROPER CABLE MANAGEMENT
By moving cables out of the horizontal
equipment mounting areas and awayfrom equipment cooling fans,
VersaPOD improves overall airflow
and cooling efficiency.
VERTICAL CABLE MANAGEMENT TRAYS
Up to 8 trays can be installed between each
set of bayed cabinets to isolate air flow from
cabinet to cabinet while facilitating routing and
slack management of cabling.
HIGH-FLOW DOORS
Front and rear doors enable over 71% air-
flow to ensure proper hot aisle/cold aisle cir-
culation. Split rear doors require smaller
opening clearance, maximizing user access
in shallow hot aisles.
OPEN FLOOR ACCESS
Each VersaPOD unit has a
completely open base, enabling
maximum air flow and routing ofcabling into or out of raised floor
pathway systems.
OPTIONAL ACCESSORIES
Each VersaPOD unit includes provisions for roof
mounted cooling fans and additional accessories
such as brush guards, blanking panels and grommets
to promote proper air flow and temperature control.
ICEPACK™ REAR COOLING DOORS
VersaPOD cabinets can be ordered without rear
doors to accept mounting of Siemon’s IcePack
rear cooling doors providing up to 31kW of
cooling capacity.
INTEGRATED ISOLATION PANELS
At the base and top of the cabinet prevents
internal recirculation of air within cabinet to
optimize thermal efficiency
-
8/18/2019 brc_versapod
9/20
8
VersaPOD THERMAL CAPACITIES
Analysis Overview: This analysis is based on a third-party thermal capacity study of the VersaPOD cabinet using CFD modeling
and uses the following parameters:
- A single 45U VersaPOD was fully populated with 1U/500W servers
- A perforated floor tile placed in front of the cabinet provides an air output of 13°C (55°F), 600CFM
- Servers were evenly removed until equipment intake temperatures met manufacturer requirements
ANALYSIS #1: STANDARD VersaPOD CABINET
- 1000mm (40 in.) VersaPOD cabinet- Perforated front and rear doors- No fans or vertical blanking panels installed
- Blanking panels are used in horizontal locations whereequipment is not present
(14) servers installed within limits of intake temperatures(14) x 500W = 7kW capacity
ANALYSIS #2: VersaPOD WITH VERTICAL EXHAUST DUCT & FANS
- 1200mm (48 in.) VersaPOD cabinet- Perforated front doors- Solid rear doors
- Vertical exhaust duct- 3 fan trays installed in top of cabinet (9 fans total)- Blanking panels are used in horizontal locations where equipment is not present
(26) servers installed within limits of intake temperatures(26) x 500W = 13kW capacity
Temperature
140˚F /60˚C
122˚F /50˚C
104˚F /40˚C
86˚F /30˚C
68˚F /20˚C
50˚F /10˚C
-
8/18/2019 brc_versapod
10/20
9
MORE USABLE SPACE = MORE DESIGN OPTIONS
While the VersaPOD’s innovative design offers unique features to improve the efficiency and manageability of all common data center environments and
configurations, its greatest benefit may be its versatility.
By making use of space wasted by traditional cabinets, VersaPOD opens the cabinet to design options not possible before. Whether you take advantage of
its extra capacity to save floor space, plan for future scalability or leverage it’s Zero-U cable management and patching capabilities to get your physical
layer under control- with VersaPOD you have the ability to design the infrastructure you really need.
Sample VersaPOD Design Options
For high density switching applica-
tions, VersaPOD’s optional Zero-U
cable managers, in conjunction with
2U and 4U cable managers, can
readily support high volume patchcord routing between switches and
patch panels. All while providing a
professional appearance.
VersaPOD’s optional Zero-U patch
panels can be mounted on the rear of
the cabinets to provide connection
points in close proximity to servers.
This allows for the use of shorterpatch cords which can be better
managed.
Note that optional management fin-
gers and associated hinging covers
can be used to optimize the
finished appearance. Alternate Zero-
U channels can be used to mount
PDU’s for power connections.
NETWORK CABINETS SERVER/STORAGE
Patch Cords
Power Cables
-
8/18/2019 brc_versapod
11/20
10
2 VersaPOD cabinets
2 Fiber switches installed in each cabinet
All fiber connectivity and management requirements con-
tained in the Zero-U space between bayed cabinets
4 Standard 600mm cabinets
1 Fiber switch installed in each cabinet
Fiber enclosures and cable management required to support
switches consumes the full equipment mounting space
VersaPOD SPACE SAVINGS EXAMPLE
The diagrams below indicate a real-world example of how VersaPOD cut a customer’s cabinet needs in half.
STANDARD CABINETS VERSAPOD
-
8/18/2019 brc_versapod
12/20
11
Siemon's 42U SidePOD and Baffle solution is designed to support side-to-side ventilated active equipment such as the Cisco Nexus®
7018 Series Switches.
The SidePOD is an option for use with Siemon’s VP2A 1200mm (48 in.) deep VersaPOD cabinets and creates the necessary clearance
for proper airflow to the switch. The baffles are used to properly route cold air from the front of the cabinet to the input side of the
switch as well as route exhaust from the output side of the switch to be vented in the hot aisle. Cisco Nexus® 7018 Operational
Compliance has been validated via Computational Fluid Dynamics (CFD) modeling under maximum operating conditions
In addition to providing a cooling platform, the SidePOD also allows full size Zero-U panels to be used in End of Row applications.
This includes up to 12U of vertical patching and high capacity vertical cable management with hinged covers.
END OF ROW CAPACITY
Increases with SidePOD so
full size Zero-U patch panels
and cable managers can be
used
CABLE ACCESS OPENINGS
Multiple openings in the lid
accept optional brush guards
to provide cable access to the
Zero-U space from overhead
distribution systems
SHARED USE OF SIDE PANELS
The SidePOD is compatible
with VP2 side panels allowing
VersaPOD panels to be
transitioned to the SidePOD when
added to end of row installations
REVERSIBLE BAFFLE DESIGN
Baffles can be installed in either
orientation to properly route either
cold air input or hot air exhaust.
Two angled baffles may be nested
180º to each other in the same
Zero-U space allowing two side-
vented switches to be mounted
next to each other
SIDEPOD™ AND BAFFLE
SidePOD – with two vented doors
adds 140mm (5.5 in.) width to
the end of row
ZERO U MODULARITY
Ensures that with a baffle installed,
the balance of Zero-U space can be
fully utilized for patching or cable
management
-
8/18/2019 brc_versapod
13/20
-
8/18/2019 brc_versapod
14/20
-
8/18/2019 brc_versapod
15/20
14
ZERO-U SLIDING PATCH PANELS ORDERING INFORMATION
VP-VPP-TMRIC VP-VPP-TMVP-VPP-6U
45U DUPLEX ZERO-U SLIDING VERTICAL PATCH PANELS
Part# Description
VP-VPP-TMRIC......................Sliding Vertical Copper/Fiber Combo Patch Panel
96 Ports, supports all category 5e and category 6 UTP MAX and Z-MAX, category 6A shielded Z-MAX outlets, TERA ®
outlets an MAX fiber adapters. (Not for use w/Z-MAX 6A UTP) 6 fiber RIC adaptor mounting spaces for mounting RIC
adapter plates or fiber plug and play modules
VP-VPP-TM...........................Sliding Vertical Copper Patch Panel96 Ports, supports all category 5e category 6, category 6A UTP MAX and Z-MAX outlets, category 6A shielded Z-MAX,
TERA outlets and MAX fiber adapters (Port spacing compatible with Z-MAX 6A UTP)
VP-VPP-6U............................Sliding Vertical Bracket for any Standard 19” Rack Mount Products
Mounts up to (6) 1U panels in Zero-U vertical
orientation
42U TRIPLEX ZERO-U SLIDING VERTICAL PATCH PANELS
Part# Description
VP-VP3U-1-42......................Standard 19” Vertical Panel, 3U
Mounts up to 3U of standard 19” panels or PDUs in vertical orientation
VP-VPTM-1-42 .....................TERA-MAX Vertical Patch Panel
48 ports, supports all category 5e and category 6 MAX and Z-MAX, category 6A UTP and shielded Z-MAX, TERA outlets
and MAX fiber adapters (port spacing compatible for Z-MAX 6A UTP
VP-VPR-1-42........................RIC Vertical Patch Panel
12 RIC adapter mounting spaces for mounting RIC fiber adapter plates or fiber plug and play modules
VP-VPTMR-1-42 ...................TERA-MAX-RIC Vertical Patch Panel
48 Ports, supports all category 5e and category 6 MAX and Z-MAX, category 6A shielded Z-MAX outlets TERA ® outlets
and MAX fiber adapters (port spacing not compatible for Z-MAX 6A UTP) - 4 fiber RIC adapter mounting spaces for
mounting RIC adapter plates or fiber plug and play modules
VP-VP3U-1-42 VP-VPTM-1-42
VP-VPR-1-42 VP-VPTMR-1-42
NOTES:
(3) VPP’s/VPCs can be mounted vertically at the front and/or rear of 2 bayed cabinets or between a VersaPOD cabinet and SidePOD
(3) VPPs/VPCs are required to fully populate 42U Zero-U space
NOTES:
(2) VPP’s/VPCs can be mounted vertically at the front and/or rear of 2 bayed cabinets or between a VersaPOD cabinet and SidePOD
(2) VPP’s/VPCs are required to fully populate 45U Zero-U space
-
8/18/2019 brc_versapod
16/20
-
8/18/2019 brc_versapod
17/20
16
Part # Description
VP-VP1U-1-42 . . . . . . . . . . . . .Vertical 19” Panel, 1U
Mounts 1U of standard 19” rack mount products
VP-VWM-1-42 . . . . . . . . . . . . .Vertical Wire Manager PanelIncludes cable management lances as well as features to allow use of Siemon’s ¼-turn cable management accessories
VP-BLNK1-1-42 . . . . . . . . . . . .Vertical Blanking Panel
Used to block off unused spaces to prevent re-circulation of air
42U TRIPLEX END OF ROW ZERO-U PANELS
VP- VP1U -1 -4 2 VP- VW M- 1- 42 VP-BLNK1-1-42
END-OF-ROW ORDERING INFORMATION
VP-VWMVP-VPP-2U VP-BLNK1
Part # Description
VP-VPP-2U . . . . . . . . . . . . . . . .Vertical 19” Panel, 2UMounts up to 2U of standard 19” rack mount products
VP-VWM . . . . . . . . . . . . . . . . . .Vertical Wire Manager Panel, end-of-row
Includes cable management lances as well as features to allow use of Siemon’s ¼-turn cable management accessories
VP-BLNK1 . . . . . . . . . . . . . . . . .Vertical Blanking Panel, end-of-rowUsed to block off unused spaces to prevent re-circulation of air
Note: 2 Vertical Panels can be mounted vertically at the front and/or rear on each side of a single cabinet or at each end of multiple bayed cabinets.
45U DUPLEX END-OF-ROW ZERO-U PANELS
NOTES:
(3) VPP’s/VPCs can be mounted vertically at the front and/or rear of 2 bayed cabinets or between a VersaPOD cabinet and SidePOD
(3) VPPs/VPCs are required to fully populate 42U Zero-U space
NOTES:
(2) VPP’s/VPCs can be mounted vertically at the front and/or rear of 2 bayed cabinets or between a VersaPOD cabinet and SidePOD
(2) VPPs/VPCs are required to fully populate 45U Zero-U space
-
8/18/2019 brc_versapod
18/20
17
ZERO-U ACCESSORIES ORDERING INFORMATION
VP-SPAN-1
VP-BLNK-1-42
Part # Description
VPA-PDU-F1-1 . . . . . . . . . . . . .Front-facing, Single PDU Mounting Bracket
Supports mounting of (1) front-facing PDU for end of row applications
VPA-PDU-F2-1 . . . . . . . . . . . . .Front-facing, Dual PDU Mounting Bracket
Supports mounting of (2) front-facing PDU’s in full size Zero-U spaces between bayed cabinets
VPA-PDU-S2-1 . . . . . . . . . . . . .Side-facing, Dual PDU Mounting Bracket. Supports mounting of (2) side-facing PDU’s. Can be used in either end of rowor full Zero-U applications between bayed cabinet
ZERO-U CABLE THROUGH
Part # Description
VPA-SPAN-1 . . . . . . . . . . . . . . .Adjustable Depth Cable Through
Used to route cables between the front and rear of cabinets.
Mounts between Vertical Patching channels mounted to front and rear of cabinets
ZERO-U BLANKING P ANELS
VP-BLNK-1-42 . . . . . . . . . . . . .Vertical Blanking PanelUsed to isolate airflow in unused Zero-U spaces within 42U cabinets
VP-BLNK . . . . . . . . . . . . . . . . .Vertical Blanking PanelUsed to isolate airflow in unused Zero-U spaces within 45U cabinets
ZERO-U PDU MOUNTING BRACKETS
VPA-PDU-F1-1 VPA-PDU-F2-1 VPA-PDU-S2-1
VP-BLNK
-
8/18/2019 brc_versapod
19/20
18
Part # Description
VPA-R-1-(XX) . . . . . . . . . . . . . .VersaPOD Equipment Mounting Rails (set of 2), Black
Use (XX) to specify height. 42 = 42U, 45 = 45U
VP-FAN . . . . . . . . . . . . . . . . . .Top-Mount Cooling Fan Panel - 3 Fans x 110CFM, 120VAC w/NEMA 5-15P plug
VP-FAN-220 . . . . . . . . . . . . . . .Top-Mount Cooling Fan Panel - 3 Fans x 110CFM, 220VAC w/C13 plug
VP-T3 . . . . . . . . . . . . . . . . . . .Brush Guard, Large - For large center top panel cable openings
VP-BRUSH . . . . . . . . . . . . . . . .Brush Guard, Small - For small perimeter top panel cable openings
VP-BAY2 . . . . . . . . . . . . . . . . .VersaPOD Baying Kit - Secures (2) VersaPOD cabinets together
VA-VPA-BAY-1 . . . . . . . . . . . . . .VersaPOD-to-V600 Baying Kit - Secures (1) VersaPOD cabinet to (1) V600 cabinet
VP-GRD . . . . . . . . . . . . . . . . . .Grounding Kit - Includes ground bar, ground wire, mounting hardware and accessories
(capacity to support all required grounding connections for a single cabinet)
RS-VCM . . . . . . . . . . . . . . . . . .¼-turn Hook and Loop Cable Managers (box of 10)
Can be installed in Vertical Cable Management Tray, Vertical Patching Channeland End of Row Vertical Wire Manager
VP-SPL . . . . . . . . . . . . . . . . . . .¼-Turn Fiber Management Spool (bag of 5)
Can be installed in Vertical Patching Channel and End of Row Vertical Wire Manager
VP-143 . . . . . . . . . . . . . . . . . . .¼-Turn D-Ring Cable Manager (box of 10) 88.9x44.5mm (3.50x1.75 in.) Can be installed
in Vertical Cable Management Trays only
VP-145 . . . . . . . . . . . . . . . . . . . ¼-Turn D-Ring Cable Manager (box of 10), 127.0x88.9mm (5.00x3.50 in.),
Can be installed in Vertical Management Trays only
HCM-4-(X)U . . . . . . . . . . . . . . .RouteIT™ 19” Horizontal Cable Manager w/4” FingersUse (X) to specify height: 1 = 1U, 2 = 2U, 4 = 4U
HCM-6-(X)U . . . . . . . . . . . . . . .RouteIT 19” Horizontal Cable Manager w/6” Fingers
Use (X) to specify height: 1 = 1U, 2 = 2U, 4 = 4U
PNL-TBLNK010-1S . . . . . . . . . .19” Toolless Blank Filler Panel, 1U (package of 10)
PNL-BRSH-1 . . . . . . . . . . . . . . .19” Brush Guard Panel, 1U
ACCESSORIES
CABINET ACCESSORIES ORDERING INFORMATION
VP-GRD
VP-FAN VP-T3
VP-143 PNL-TBLNK010-1S
RS-VCM
HCM-4-(X)U HCM-6-(X)U
VP-SPL
PNL-BRSH-1
-
8/18/2019 brc_versapod
20/20
WWW.SIEMON.COM
Worldwide HeadquartersNorth AmericaWatertown, CT USAPhone (1) 860 945 4200 USPhone (1) 888 425 6165
Regional HeadquartersEMEAEurope/Middle East/AfricaSurrey, EnglandPhone (44 ) 0 1932 571771
Regional HeadquartersAsia/PacificShanghai, P.R. ChinaPhone (86) 21 5385 0303
Regional HeadquartersLatin AmericaBogota, ColombiaPhone (571) 657 1950