br-bss timers mapping v2
TRANSCRIPT
-
7/30/2019 BR-BSS Timers Mapping V2
1/4
BSS parameter Protocol
T1
BSSMAP timers
T13 BSSMAP timers
T17 BSSMAP timers
T18 BSSMAP timers
T19 BSSMAP timers
T20 BSSMAP timers
N/A
T3121
T4 BSSMAP timers
T7 BSSMAP timers
T10 BSSMAP timers
T3107
T3103
T8 BSSMAP timers
T3122
T3101
T3109
T3111
T3168
T3192
TLC
BSSMAP
N/A
TLWBSSMAP
N/A
TLHBSSMAP
TLWHBSSMAP
.
-
7/30/2019 BR-BSS Timers Mapping V2
2/4
Signification BSS Obj Range
Timer T1 specifies the time limit in which the remote end of the connection must acknowledge
the receipt of the frame. If this timer expires, the frame is transmitted again.BSC 10s
RESET guard period BSC 5..30s
Overload procedure (The timer T17 supervises the overload procedure in MSC overload.) BSC 1..120s
Overload procedure(The timer T18 supervises the overload procedure. For a detailed
description see 3GPP TS 08.08, MSC-BSS Interface, Layer 3 Specification.)BSC 3..180s
BSC 10s
BSC 10s
N/A N/A
GSM to WCDMA RAN handover procedure supervision in the source BSC BSC 8..15s
Supervision of sending the RESET to the MSC BSC 10..120s
Frequency of the HANDOVER_REQUIRED message BSC 5..30s
Supervision of the assignment procedure BSC 4..14s
Supervision of the assignment procedure BSC 3.5..28s
Supervision of the internal handover procedure BSC 3.5..28s
Handover procedure supervision in the source BSC BSC 8..15s
Delay of sending another channel request message BSC 2255s
Supervision of the immediate assignment procedure BSC 1..5s
Supervision of the channel release procedure BSC 8..15s
Delay of channel deactivation BSC 0.5s
Wait for Packet Uplink Assignment message BSC 0..7
Wait for release of the TBF after reception of the final block BSC 0..2
With this parameter you define the maximum queueing time for call attempts(incoming or outgoing) in the BTS in seconds. Value 0 deactivates call attempt
queueing.
BTS 0...15s
With this parameter you define the maximum queuing time in seconds for WPS call
setup attempts.BTS 0...30s
With this parameter you define the maximum queueing time for handover attempts
(both urgent and non-urgent) in the BTS in seconds.BTS 0...10s
With this parameter you define the maximum queuing time in seconds for WPS
handover attemptsBTS 0...30s
Flexi BSC
-
7/30/2019 BR-BSS Timers Mapping V2
3/4
BSS Default
ValueBR Obj BR Parameter BR Value
Mapped Value
To BR's
what is applied
now in
siemens
10s BSC BSCT1 HLFSEC-12 10s
15s BSC BSCT13 HLFSEC-50
4s BSC BSCT17 HLFSEC-20
12s BSC BSCT18 HLFSEC-60
10s BSC BSCT19 HLFSEC-12 10s
10s BSC BSCT20 HLFSEC-12 10s
N/A BSC BSCT3 HLFSEC-50 N/A
12s BSC BSCT3121 HLFSEC-10
60s BSC BSCT4 HLFSEC-60
20s BSC BSCT7 HLFSEC-12
8s BSC
6s BSC
6s BSC
12s BSC
6s BSC T3122 5 5s T3122=5
3s BTS T3101 HLFSEC-6 3s HLFSEC-6
4s BTS T3109 HLFSEC-8 4s HLFSEC-8
0.5s BTS T3111 HLFSEC-3 0.5s
2 BTS T3168 2 2 T3168=2
0 BTS T3192 0 0 T3192=0
10s BSC BSCT11PUB HLFSEC-12 6 HLFSEC-20
BSC BSCT14PUB HLFSEC-16
28 s BSC BSCT11WPS HLFSEC-16 0
BSC BSCT14WPS HLFSEC-16
5s BSC BSCTQHOPUB HLFSEC-6 3 HLFSEC-6
5s BSC BSCTQHOWPS HLFSEC-20 0
Siemens BSC
BSCT8 HLFSEC-10
BSCT10 HLFSEC-10
-
7/30/2019 BR-BSS Timers Mapping V2
4/4
Comment
Fixed value
Since the used value in BR is the default value then the default value of BSS is
recommended
Since the used value in BR is the default value then the default value of BSS is
recommended
Since the used value in BR is the default value then the default value of BSS is
recommended
Fixed value
Fixed value
N/A
Since the used value in BR is the default value then the default value of BSS is
recommended
Since the used value in BR is the default value then the default value of BSS is
recommended
BSS default value is recommended
Mapped
Mapped
Mapped
Fixed value
Mapped
Mapped
Mapped
WPS is not used
Mapped