    1/14Page 1

    PRPOSED OFFICE FOR THANGAMAIL JEWELLERS-MADURAI

    DESCRIPTION QTY UNIT

    1 Meter Panel

    1 No 32000 4,000

    2 MAIN PANEL

    Incomer:

    125A TP MCCB (25ka) -1 NO

    125/5A, Tape Wound Type Metering CT-3NOS

    Busbar-200A (Copper):

    Outgoings

    63A TP MCCB -8 NOS 1 No 110000 10,000

    3 AMF PANEL

    1 No 2,000

    4 LIGTHING DB

    SL.NO.

    SUPPLYRATE

    LABORERATE

    Supply, Erection, Testing and commissioning of front

    operated floor mounting Three comportment cubical Meter board for 100A. E.B meter. Suitable for 415V 3 Phase50Hz supply comprising of the followings 3 Nos 200A,500V porcelain cut outs for rewirable fuses with 1 No100A neutral link and 125A cubical switch as a out going(necessary sealing arrangement etc should be provided asper the local EB norms )

    Supply,Erection,Testing and Commissioning of cubicle,Floor Mounting Type, Panel made out of 2 mm thickCRCA Sheet duly applied with Siemens Grey TexturePowder Coating comprises of the following:

    1No (0 125)A, 96Sqmm. Digital Ammeter withAmmeter Selector Switch

    1No (0 500V), 96Sqmm. Digital Voltmeter with

    Voltmeter Selector Switch

    Erection,Testing and Commissioning of cubicle, FloorMounting Type, DG AMF PANEL made out of

    14/16SWG CRCA Sheet duly applied with Siemens GreyTexture Powder Coating

  • 8/9/2019 boq tm off (1)

    2/14

    Page 2

    Incomer:

    40A FP MCB - 1 NosOutgoings

    32A DP RCBO (30mA) - 3 Nos

    6A SP MCB - 12 Nos 1 No 18000 2,000

    5 POWER DB

    Incomer:

    63A FP RCBO (30mA) - 1 NosOutgoings

    25A SP MCB - 3 Nos

    16A SP MCB - 9 Nos 1 No 10700 700

    6 INVERTER DB

    Incomer:

    32A DP MCB - 1 Nos

    Outgoings

    6A SP MCB - 10 Nos 2 Nos 4000 500

    7 UPS Way Box

    2 Nos 1150 500

    8 CABLES

    a 3.5C x 50 SQ.MM CU.AR.CABLE 15 Mtrs 1350 150

    b 4C x 16 SQ.MM CU.AR.CABLE 15 Mtrs 250 50

    Supply, Erection,Testing and Commissioning of DoubleDoor IP42 3 phase 4 WAY 7COMPARTMENT DBComprising of the following

    Supply, Erection,Testing and Commissioning of DoubleDoor IP43 4 WAY VTPN DB Comprising of thefollowing

    Supply, Erection,Testing and Commissioning of DoubleDoor IP43 12 WAY SPN DB Comprising of thefollowing

    Supply, Erection and fixing of 40DP Mcb with suitableMetal Enclosure for controling the UPS incomer

    Supply and Laying of following 1100 volt grade XLPEinsulated armoured cable as per specification in trenches,cable trays ducts over bed of sand, clamped to wall withsuitable clamps, including fixing bolts, connecting testingand commissioning.

  • 8/9/2019 boq tm off (1)

    3/14

    Page 3

    c 4C x 10 SQ.MM CU.AR.CABLE 30 Mtrs 400 50

    d 4C x 6 SQ.MM CU.AR.CABLE 30 Mtrs 280 45

    e 3C x 6 SQ.MM CU.AR.CABLE 30 Mtrs 210 40

    f3.5C x 50 SQ.MM AL.AR.CABLE 75 Mtrs 300 60

    g 3.5C x 35 SQ.MM AL.AR.CABLE 20 Mtrs 275 40

    h 1C 6 Sq.mm CU cable flexible cable 50 Mtrs 45 15

    9 TERMINATION

    a 3.5C x 50 SQ.MM 4 Nos 250 100

    b 3.5C x 50 SQ.MM 4 Nos 250 100c 4C x 16 SQ.MM 2 Nos 220 30

    d 4C x 10 SQ.MM 4 Nos 150 50

    e 4C x 6 SQ.MM 4 Nos 150 50

    f3C x 6 SQ.MM 4 Nos 125 50

    POINT WIRING

    10

    20 Pts 690 125

    11

    18 Pts 1065 150

    Supply and End termination of the following XLPEinsulated sheathed aluminium/copper conductor armouredcables of 1.1kv grade including supplying and fixing ofbimettalic crimping Lugs, Single compression glands withearthing.

    Supply,Laying and Termination of One Light pointcontroll by one switch, 3 runs 1.5 sqmm copper conductor1.1kv grade stranded flexible FRLS wire for phase neutraland earthing run through a medium duty ISI PVC conduit

    with all accessories as per the controls given in theDrawings. ( average point length 8 Mtrs )

    Supply,Laying and Termination of Two Light pointcontroll by one switch, 3 runs 1.5 sqmm copper conductor1.1kv grade stranded flexible FRLS wire for phase neutraland earthing run through a medium duty ISI PVC conduitwith all accessories as per the controls given in theDrawings. ( average point length 12 Mtrs )

  • 8/9/2019 boq tm off (1)

    4/14

    Page 4

    12

    17 Pts 920 150

    Supply,Laying and Termination of One Fan point controllby one switch with Step type electronice fan regulatore, 3runs 1.5 sqmm copper conductor 1.1kv grade strandedflexible FRLS wire for phase neutral and earthing runthrough a medium duty ISI PVC conduit with allaccessories as per the controls given in the Drawings.

    ( average point length 8 Mtr )

  • 8/9/2019 boq tm off (1)

    5/14

    Page 5

    CIRCUIT MAIN

    13

    200 Mtrs 110 30

    14

    300 Mtrs 110 30

    15

    100 Mtrs 130 40

    16

    35 Nos 750 100

    17

    5 Nos 675 75

    18

    35 Nos 1525 250

    EARTHING

    19

    2 Nos 6450 750

    Supply,Laying and Termination of 3 Runs 2.5 sq mmcopper conductor 1.1kv grade stranded flexible FRLS wirefor phase neutral and earthing run through a medium dutyISI PVC conduit with all accessories forLighting Circuits

    Supply,Laying and Termination of 3 Runs 2.5 sq mmcopper conductor 1.1kv grade stranded flexible FRLS wirefor phase neutral and earthing run through a medium dutyISI PVC conduit with all accessories forUPS Circuits

    Supply,Laying and Termination of 2 Runs 4 sq mm and 1Runs 2.5 sq mm copper conductor 1.1kv grade strandedflexible FRLS wire for phase neutral and earthing runthrough a medium duty ISI PVC conduit with allaccessories forPower Circuits

    Supply and Fixing of 2 nos 6A 5pin socket and 1 no 6Aswitch, molded front plate G1 enclosure with allaccessories

    Supply and Fixing of 1 nos 15/6A socket and 1 no 16Aswitch, molded front plate G1 enclosure with allaccessories

    Supply and Fixing of 5 nos 6A 5pin socket and 1 no 16Aswitch with indicator, molded front plate G1 enclosure withall accessories forComputer point

    Supply and Installation of 300 X 300 X 1.5 mm thickcopper plate earth electrode fitted on 40mm dia, 3 mtrlength GI pipe with hole for watering as per IE3043 rulefor generator neutral and UPS neutral earthingcomplete with providing salt and charcoal (except civilwork)

  • 8/9/2019 boq tm off (1)

    6/14

    Page 6

    20

    4 Nos 2750 750

    21 25X 1.5mm copper flat 100 Mtrs 230 30

    22 No 10 SWG copper 80 Mtrs 53 12

    23 FIXING OF LIGHT FITTING

    a Fixing of 1x18w CFL Down type fitting 15 Nos 65

    b

    Fixing of 2x36w TL Recess mounted type fitting

    14 Nos 50

    cFixing of 2x18w CFL Recess mounted type fitting

    20 Nos 55

    d Fixing of Celling Fan fitting 17 Nos 80

    L.V SYSTEM

    24

    700 Mtrs 40 10

    25

    700 Mtrs 65 15

    26

    35 Nos 235 25

    2735 Nos 535 25

    28 Supply and Fixing of CCTV Cable in a suitable PVC Conduits.

    500 Mtrs 63 12

    29

    100 Mtrs 75 15

    30

    100 Mtrs 75 15

    31

    50 Mtrs 60 10

    Supply and Installation of 40mm dia, 2 mtr length GI pipeearth electrode as per IE 3043 rule forbody and dedicateearthing complete with providing salt and charcoal(except civil work)

    Supply and laying of following sizes of copper wire /flatlaying on cable trench /wall/ground etc with suitable fixingarrangements

    Supply and Laying of 2 Pair Telephone run through amedium duty ISI PVC conduit with all accessories for

    Supply and Laying of CAT6 Data cable run through amedium duty ISI PVC conduit with all accessories for

    Supply and Fixing of Telephone Jack with molded frontplate G1 enclosure with all accessories

    Supply and Fixing of Data Jack with molded front plate G1enclosure with all accessories

    Supply and Laying ofPIR- Wiring with 4 Runs of 1 Sq.mm wire insuitable PVC Conduit.

    Supply and Laying ofSD - Wiring with 4 Runs of 1 Sq.mm wire insuitable PVC Conduit.

    Supply and Laying ofSiren - Wiring with 2 Runs of 1 Sq.mm wire insuitable PVC Conduit.

  • 8/9/2019 boq tm off (1)

    7/14

    Page 7

    32

    100 Mtrs 60 10

    Total

    ( RUPEES SEVEN LAKHS EIGHTY NINE THOUSAND SEVEN HUNDRED SEVENTY ONLY )

    Note:

    1. The quantities are approximate. The bills for actual quantity used.

    2. Works other than mentioned are under separate quotation.

    3.This excludes transport

    4. This Includes VAT.

    5. Labour bill payment may be released in parts for each section of work.

    6. Payment: 30% advance. 70% for materials after delivery.

    Supply and Laying ofMagnetic Sensor - Wiring with 2 Runs of 1Sq.mm wire in suitable PVC Conduit.

  • 8/9/2019 boq tm off (1)

    8/14

    Page 8

    TOTAL

    36,000 36,000

    120,000 120,000

    2,000 2,000

    TOTALAMOUND

  • 8/9/2019 boq tm off (1)

    9/14

    Page 9

    20,000 20,000

    11,400 11,400

    4,500 9,000

    1,650 3,300

    1,500 22,500

    300 4,500

  • 8/9/2019 boq tm off (1)

    10/14

    Page 10

    450 13,500

    325 9,750

    250 7,500

    360 27,000

    315 6,300

    60 3,000

    350 1,400

    350 1,400250 500

    200 800

    200 800

    175 700

    815 16,300

    1,215 21,870

  • 8/9/2019 boq tm off (1)

    11/14

    Page 11

    1,070 18,190

  • 8/9/2019 boq tm off (1)

    12/14

    Page 12

    140 28,000

    140 42,000

    170 17,000

    850 29,750

    750 3,750

    1,775 62,125

    7,200 14,400

  • 8/9/2019 boq tm off (1)

    13/14

    Page 13

    3,500 14,000

    260 26,000

    65 5,200

    65 975

    50 700

    55 1,100

    80 1,360

    50 35,000

    80 56,000

    260 9,100

    560 19,600

    75 37,500

    90 9,000

    90 9,000

    70 3,500

  • 8/9/2019 boq tm off (1)

    14/14

    70 7,000

    789,770