Bookstack Lighting at McHenry Library 2016 Best Practices Award Lighting Retrofit Category

Upload: others

Post on 23-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Bookstack Lighting at McHenry Library 2016 Best Practices Award

Lighting Retrofit Category

Page 2: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Project Description

● Specifically address bookstack lighting

● Pre-existing controls = ON/OFF (no dimming)

● Projects completed in other areas of the building left stacks mostly untouched

● Scope: LED Fixture conversion; add occupancy & dimming capability

Page 3: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

● Lots of light required when occupied

● Largely UN-occupied during open hours (datalogging showed ~6%-9% occupancy)

● Lights were scheduled ON for many hours before & after library’s open hours, for custodial & staff (~3 hrs/day or 1000 hrs/year)

● On/off occupancy control not an option - a large section of unlit book stacks is not a viable solution to the library staff – it looks creepy

Library Bookstacks – a unique space

Page 4: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Best Practices Demonstrated • Schedule optimization • Demand-based

Illumination • Deep Green: Fixtures &

Controls

• Strategic sensor placement for cost savings

• Collaboration

Page 5: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Design & Planning

● Used software simulation to aid in fixture choice

○ Lumen levels considered at work plane as well as on the faces of bookstacks

● Created a lighting fixture & control capability “wish list”

○ non-OFF, but dimmed, vacant setting

○ ability to schedule changes in control settings in advance

○ sweep on* function

○ high CRI

○ visibility of books on all shelves Dialux lighting model simulation from occupant POV

Page 6: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Optimized Lighting Schedule:

Demand-based Illumination

● Sweep on to

low/unoccupied level only

during open hours

● During closed hours, low

level = OFF

● Different profiles & light

levels for different areas’

needs/use patterns

Page 7: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Deep Green: Fixtures & Controls

● Financial implications ● Design concerns - responsibility ● Constructability and scheduling

impact consideration ● Occupant happiness (before, during

& after project) ● …

Longer payback project now would lead to lowest overall cost of ownership for the lifetime of the project.

Page 8: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Collaboration with Occupants

• Early-on establishment of communication flow process

• Key occupant: facility coordinator

• Point of contact in general, but emphasis on reaching out to wider occupant/stakeholder group regularly

Page 9: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Project Results

Total project cost: $698,449.90

Estimated annual energy savings: 407,548 kWh

Estimated GHG Emissions reduction: 79.06 MTCO2e / year

Page 10: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Lessons Learned • Getting the ball rolling is

important

• Collaboration with occupants – before and AFTER is important

• Clarity with contractor

Page 11: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Before & After

Page 12: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Before & After

Page 13: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;

Before & After

Page 14: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;
Page 15: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;
Page 16: Bookstack Lighting at McHenry Library › wp-content › uploads › CHESC2016... · 2019-11-13 · Lighting Retrofit Category . Project ... untouched Scope: LED Fixture conversion;