BOOK OF MEASSUREMENTS

SAGAR

SAGAR LENSESLED

EN

MountingPole-side entry installation (PMT)Light sourceLEDOptical systemLensesWiringElectronic control gear FIX (ECG)External lead-in flexible cableMaterialsHousing: die-cast aluminiumCover: polycarbonateSurface finishHousing: grey RAL 9006 (G06)Service lifetime50,000 hours/L70/B50 (ta 25°C) Ambient temperatureFrom -30 °C to +45 °C

DE

MontageSeitenansatz-Installation (PMT)LichtquelleLEDOptisches SystemLinsenVorschaltgerätElektronisches Vorschaltgerät FIX (ECG)Externes AnschlusskabelMaterialKörper: AluminiumdruckgussAbdeckung: PolykarbonatOberflächenveredelungKörper: grau RAL 9006 (G06)Lebensdauer 50,000 Stunden/L70/B50 (ta 25°C) UmgebungstemperaturVon -30 °C bis +45 °C

FR

MontageInstallation d´entrée latérale (PMT)Source lumineuseLEDSystème optiqueLentillesÉquipement électriqueBallast électronique FIX (ECG)Artére externeMatérielsCorps: aluminium moulé sous pressionCouvercle: polycarbonateFinition de surfaceCorps: gris RAL 9006 (G06)Durée de vie utile50,000 heures/L70/B50 (ta 25°C) Température ambianteDe -30 °C à +45 °C

Sagar

NEW

THE MANUFACTURER CONTINUES TO DEVELOP PRODUCTS THROUGHOUT THEIR LIFETIME. THEREFORE, THE COMPANY RESERVES THE RIGHT TO MODIFY MATERIALS, COMPONENTS, AND TECHNICAL PARAMETERS WITHOUT NOTICE. LUMINOUS OUTPUT AND ELECTRICAL LOAD HAVE AN INITIAL TOLERANCE OF +/- 10 % FROM NOMINAL. FAILURE OF ONE LED LIGHT POINT WITHIN A LUMINAIRE DOES NOT IMPAIR FUNCTIONAL PERFORMANCE AND SO IS NOT CLASSIFIED AS REASON FOR COMPLAINT.

LED

LU

MIN

AIR

ESRU

УстановкаУстановка со стороны входа (PMT)Источник светаLEDOптическая системаЛинзы Электрическое оснащениеЭлектронный пускорегулирующий аппарат FIX (ECG)Внешний свинца в гибком кабелеМатериалКорпус: литой алюминийКрышка: поликарбонатОтделка поверхностиКорпус: серый RAL 9006 (G06)Cрок службы50,000 часов/L70/B50 (ta 25°C) Температура окружающей средыОт -30 °C до +45 °C

SAGAR6200 lm 4000 K

LOR = 100%lower flux fraction 100%upper flux fraction 0%

SK

MontážMontáž zo strany (PMT)Svetelný zdrojLEDOptický systémŠošovkyElektrická výbavaElektronický predradník FIX (ECG)Prívodný napájací kábelMateriálTeleso: hliníkový odliatokKryt: polykarbonátPovrchová úpravaTeleso: šedá RAL 9006 (G06)Servisná životnosť 50,000 hodín/L70/B50 (ta 25°C) Teplota okoliaOd -30 °C do +45 °C

ES

MontajeInstalación de acceso lateral (PMT)Fuente lumínica LEDSistema ópticoLentesCableadoEquipo de control electronico FIX (ECG)Cable alimentador externoMaterialCuerpo: aluminio moldeadoCubierta: policarbonatoTratamiento de la superficieCuerpo: gris RAL 9006 (G06)Vida útil50,000 horas/L70/B50 (ta 25°C) Temperatura ambienteDesde -30 °C a +45 °C

IT

InstallazioneInstallazione ingresso laterale (PMT)Sorgente luminosa LEDSistema otticoLenti CablaggioBallast elettronico FIX (ECG)Cavetto di alimentazione esternoMaterialiCorpo: pressofusione di alluminioCopertura: policarbonatoFinitura Corpo: grigio RAL 9006 (G06)Durata di vita50,000 ore/L70/B50 (ta 25°C) Temperatura d’ambienteDa -30 °C a +45 °C

MOUNTING

TYPE NET LUMENOUTPUT

(at Ta = 25°)

POWERCONSUMPTION

SYSTEMEFFICACY

COLOUR RENDERING

INDEX

CORRELATEDCOLOUR

TEMPERATURE

WINDAGE AREA

SIDE / TOP

WEIGHT RECOMENDEDMOUNTING

HEIGHT

REPLACEMENTOF

STANDARD(lm) (W) (lm/W) CRI (Ra) CCT (K) (m2) (kg) (m)

SAGAR 3700 30 123 70+ 4000 0.036/0.012 2.3 5-8 HPS 70 W

SAGAR 6200 50 124 70+ 4000 0.036/0.012 2.5 7-10 HPS 100 W

Luminous flux tolerance +/- 10%

90

75

60

45

C0.0-C180.0 C90.0-C270.030 15 0 15 30

90

45

60

75

cd/klm

400

500

166 478

ø 61

81

Evaluation_SAGAR

Page 1 / 5 of measurement report F-RAD-26, Rev 1

Photometric report

Measurement no.: 1642 Date of measurement: 12.04.2018

Request ID: 3645 Šalík Number of pages: 5

Tested luminaire: SAGAR 50W 6200lm 740 sample 2

Producer of luminaire:

Light source: LED

Driver specification: Model: SS-50U-54

Luminaire description: Lens together cover of LED, external sample_2

Testing laboratory: LIC, OMS, a.s., Dojč 419, 906 02, Slovakia

Tested by: Jaroslav Rýzek

Testing equipment: goniophotometer Technoteam RiGO801, S/N: 801-20, calibration 2014-11

power analyzer NORMA 3000

AC/DC power supply STATRON AG, SXIH-1P-X20SA

Measurement according to EN 13032, method near field goniophotometer.

Total uncertainties of measurement (as estimated at the 95% confidence interval):

luminous intensity 4 %, angle ±0.1°, voltage ±0.5%, current ±0.5%

Ambient temperature: 25°C Humidity: 45%

Stabilization criterion: ± 0.5% of Φ per 30 minutes Total operating time: 40 minutes

Distance between C planes: 2.5° Step: 2.5° Range: 90°- 270°

Tilt during measurement: 0° Camera used: yes

Measurement description: luminaire was measured in the normal operating position

luminous flux: (6152±799*) lm LOR: 100%

system efficiency: 124 lm/W beam angle: 151° Imax: 867 cd/klm γmax: 65° luminous flux up: 0 % luminous flux down: 100 % axis symmetry in: C0-C90 power factor: 0.96 system power: 50 W voltage, current: 230.1V, 0.22A colour temperature: 4000K CRI: 75

* This result includes expanded measurement uncertainty with the coverage factor k = 2 which corresponds to the interval having level of confidence of 95% for assumed normal

distribution. The measured uncertainty is expressed according to GUM (Guide to the expression of uncertainty in measurements, BIPM/ISO, 1993, 1995).

Measurement uncertainties of luminous flux 2%

Stability of the light source 0.5%

Stability of the power supply 0.5%

Uncertainty of realisation of V(λ) response 1%

Variation of luminous flux of LED based light sources 8%

Variation of luminous flux of fluorescent/discharge based light sources 5%

The value of the relative expanded uncertainty, Ur, is estimated to be 16%, i.e. UUr

Evaluation_SAGAR

Page 2 / 5 of measurement report F-RAD-26, Rev 1

Light intensity distribution curve (polar):

In charge of test: Report reviewed by:

Jaroslav Rýzek Denis Pavlík

Laboratory technician Laboratory technician

Evaluation_SAGAR

Page 3 / 5 of measurement report F-RAD-26, Rev 1

Light intensity distribution curve (Cartesian):

Cone diagram:

Evaluation_SAGAR

Page 4 / 5 of measurement report F-RAD-26, Rev 1

Isolux diagram:

UGR table:

Evaluation_SAGAR

Page 5 / 5 of measurement report F-RAD-26, Rev 1

Table of sizes:

Luminaire`s dimensions:

Luminous area length/Diameter 410 mm

length/diameter 170 mm

width 165 mm

width: 120 mm

height 75 mm

Pictures of measured luminaire, driver and 3D :

D

Evaluation_SAGAR

Page 1 / 3 of measurement report F-RAD-26, Rev 1

Colorimetric Measurement (sphere-spectroradiometer)

Date of measurement: 27.03.2018

Request ID: Number of pages: 3

Tested luminaire:

Light source:

Driver specification:

3637 Šalík

SAGAR 50W 6200lm 4000K Ra75

LED

Model: SS-50U-54

Testing equipment: 2m integration sphere LFC-200 S/N: 18114734L

Spectroradiometer CDS-610 S/N: U01822 DC Power Supply Maynuo M8811 S/N: 008010960130328017 4π spectral radiant flux calibration lamp SCL-600 (calibrated against NIST-RF0816)

S/N: SCL-600-E120 Auxiliary lamp Aux-50 S/N: n.a.

Correction applied: self-absorption of both the reference standard and the tested unit.

Ambient temperature: (25±1)°C Operation time before the measurement: 0 hour

Stabilisation time: 15 min Total operating time: 20 minutes

Sphere coating: BaSO4 Spectroradiometer bandwidth: 2 nm

Burning position: the device under test was oriented upwards during the measurement.

CCT: 3998 K CRI: 75.89

x: 0.3806 y: 0.3774

In charge of test:

Laboratory technician

Evaluation_SAGAR

Page 2 / 3 of measurement report F-RAD-26, Rev 1

Evaluation_SAGAR

Page 3 / 3 of measurement report F-RAD-26, Rev 1

Pictures of measured luminaire and driver:

Thermal report

Results from thermal measurement is only for object of testing. This thermal measurement should be interpreted only the entire contents,otherwise only with written agreement of thermal laboratory from iLumtech

EVALUATION

Tested luminaire / sample Sagar 50W FIX 4000K IP66 Ta45

Measurement date 13:32 28. 3. 2018Report number 2322ID Request 3637Conducted by Norbert MestanekApplicant Radoslav SalikDescription of sample ProductLED / LAMP model LED Nichia NF2L757DRName of PCB 1xST19-050-0302(A) 7S9P MC

Control gear specificationSosen SS-50U-54, ClassI, IP67, SELV, Uout=32-54V,Iout=1050mA, Iout=50W, Ta=+60°C, Tcmax=85°C; set driving current = 1050mA

Active cooling Not usedPassive cooling Heatsink is part of bodyThermal interface material Not usedMounting position / Box dimension Streetlight luminaire

Test specification

European Standard(s):STN EN 60598-1 Luminaires.Part 1: Generalrequirements and testsSTN EN 60598-2-3 Luminaires. Part 2-3: Particularrequirements. Luminaires for road and street lightingThermal test: Normal conditions with 230V AC.

Testing equipment used

Thermal chamber: TK2M with upgrade, 230V AC/10A,1600W,LxWxH=2000x900x2200mm, max. 75 °CThermocouples: Easytherm K-type (from -40 to +400 °C)DAQ system: NI cDAQ-9178 with modules (see table ofCalibrated devices)Wattmeter EMOSFHT 9999Infrared Thermal Imaging Camera Fluke Ti32Digital Multimeter VOLTCRAFT MT-52

Test Description Look at work instruction for thermal measuremetPI-RAD-TL02

Page 1 of 6iLumTech by OMS, a.s.

Created On 29. 3. 2018 11:10:38

Calibrated devices:

EVALUATION

Device Certificate number Manufacturer Date of calibration Cycle ofcalibration

Serial & Partnumber

Module NI 9211 4580043.1 NationalInstruments 13-May-2016 24 months 18C5E88 &

198864C-01LModule NI 9211 4579963.1 National

Instruments 13-May-2016 24 months 15A5BAF &198864C-01L

Module NI 9211 4536574.1 NationalInstruments 18-Apr-2016 24 months 15A5B95 &

198864C-01LModule NI 9211 4239151.1 National

Instruments 13-Aug-2015 24 months 1A746CE &198864C-01L

Module NI 9225 4580077.1 NationalInstruments 13-May-2016 24 months 158F221 &

198862A-01LModule NI 9225 4533847.1 National

Instruments 14-Apr-2016 24 months 172107F &198862A-01L

Module NI 9227 124011-02 NationalInstruments 10-May-2016 24 months 15B02A9 &

198919A-01LModule NI 9227 122016-01 National

Instruments 07-Apr-2016 24 months 175D6D4 &198919A-01L

ETI Therma 1Thermometer 3952P/17 ETI Ldt. 04-July-2017 24 months D13450496

IR Camera 3950P/17 Fluke 04-July-2017 24 months Ti32 10060234Energy Metter

FHT 9999 6254/2017 Voltcraft 14-July-2017 24 months MP/0067

Page 2 of 6iLumTech by OMS, a.s.

Created On 29. 3. 2018 11:10:38

Measurement setup:

Fig. 1: Mounting position of luminaire in the thermal chamber (left) and front view of luminaire (right)

Fig. 2:Back view (left) and position of sensors inside luminaire (right)

Fig. 3: Detail of used PCB with LEDs (left) and driver (right)

EVALUATION

Page 3 of 6iLumTech by OMS, a.s.

Created On 29. 3. 2018 11:10:38

Fig. 4: IR picture of luminaire - back side (left) and front side (right)

Fig. 5: System current, measured (left) and system voltage, measured (right)

Fig. 6: Driving current, measured (left) and driving voltage, measured (right)

EVALUATION

Page 4 of 6iLumTech by OMS, a.s.

Created On 29. 3. 2018 11:10:38

Fig. 8: Thermal plot, measured at critical points

EVALUATION

Page 5 of 6iLumTech by OMS, a.s.

Created On 29. 3. 2018 11:10:38

Fig. 7: Module power, calculated (left) and system power, calculated (right)

Result summary:

Conclusion / Comment of thermal test report:

Tested luminare Sagar 50W 4000K IP66 Ta45 passed succesfully the thermal test (normal condition) in ambient temperature Ta = 44,8°C.No temperatures, measured in critical points were exceeded.1) Maximum allowed LED case temperature, valid for forward current 1050mA / 9 strings of LEDs = 116mA perLED is based on datasheet value of LED producer - L80 for lifetime 60,000 hours.2) Value is defined by manufacturer, for lifetime 55,000 hours.3) According Standart STN EN 60598-1.4) According Standard STN EN 60598-2-3 section 3.12.1 luminairy PASSED the thermal test because is defined10°C reduction which can use only for oudoor with thermal chamber defined in standard.Note: IR camera measurement can be useful to get a quick visual representation of the heat spreading through anLED system to see any potential hot spots and for other relative comparisons. However, using an IR camera forabsolute temperature measurement can be very complex and lead to inaccurate results.

EVALUATION

Current [A] - measured Voltage [V] - measured Power [W] - calculatedSystem 0,214 233,15 48,82Channel 1 1,050 40,71 42,76

According STN EN Clause 12.4Temperatures Test A [230V] Test B [230V] Maximum allowable UnitIn test room 25 25 -- °CIn thermal chamber 44,8 4) 44,8 75 °CTc LED 1 78,2 68,2 1) 85 °CTc LED 2 77 67 1) 85 °CTc LED 3 79,1 69,1 1) 85 °CTc driver 72,5 62,5 2) 75 °CTop of lum 67,9 57,9 3) 90 °CWire 59,3 49,3 3) 125 °C

Page 6 of 6iLumTech by OMS, a.s.

Created On 29. 3. 2018 11:10:38

Pre-certification EMC Report

Measurement devices with/without certifications:

EVALUATION

Report number 0883ID request / Request name 3637 / Radoslav SalikName of Equipment Under the Test (EUT) Sagar 50W 4000K IP 66

Tested by Norbert MestanekTest specifications STN EN 55015:2013 + A1:2015 + A2:2009Used limits 55015 Qp, 55015 Av, 55015 A1 - Annex B CDNDate of measurement 13:44 28. marca 2018Description of electronic components Sosen SS-50U-54, ClassI, IP67, SELV, Uout=32-54V,

Iout=1050mA, Iout=50W, Ta=+60°C, Tcmax=85°CDescription of light source LED Nichia NF2L757DR

NotesStandart verification EMC (RF conducted andindependent method of emissions) test of equipmentunder the test .Class I EUT.

Testing equipment used

PMM LISN L2-16B,PMM EMI Receiver 9010/30P,Wooden table 2000x800x900 mm,Wall metal plate 2000x2000x1mm,Groung metal plate 2000x1000x1mm,Wattmeter EMOS FHT9999,Digital multimeter VOLTCRAFT MT-52.Table metal plate 1800x1000x1mm,Attenuator: BIRD CE Model 75-A-MFN-06,CDN: TESEQ CDN M316B,

Description of equipment under test StreetlightEnviromental conditions Temperature : 25°C +- 5°C

Relative humidity: 40%...60%

Test procedures

a) Radio-frequency conducted emissions:The equipment under test (EUT) is placed on a

wooden table 0,8 m high and powered through LISN withmetal plates on the wall and under the table which aregrounded. The EUT is operated under a normaloperating conditions. Measurement of conducteddisturbances is performed in the frequency range from0,009 MHz to 30 MHzb) Radio-frequency (independent method) of radiatedemissions: This independent method of measurement radiatedemissions are passed - described in the annex of normSTN EN 55015/A1, in the frequency range from 30 MHzto 300MHz, defined in this norm path 4.4.2.

Device name Serialnumber Range Manufacturer Date of

calibrationCycle of

calibrationCertificatenumber

PMM EMIRECIEVER9010/30P

011WX10610

50ohm 10Hz - 30MHz,30MHz - 3GHz

NARDA PMM(Teste CZ) 27/09/2017 24 month 10610-C709

PMM LISN L2-16B

000WX10607

Umax = 250V~ ,Imax = 16A~

NARDA PMM(Teste CZ) 18/09/2017 24 month 10607-C709

TESEQ CDNM316B 32611 0,15MHz - 300MHz TESEQ GmbH 01/09/2017 24 month A025965-

P961Attenuator 75-A-

MFN-06 1235142 0,15MHz - 300MHz BIRD CE(Teste CZ) 04/11/2017 24 month 710AT3740

Page 1 of 5iLumTech by OMS, a.s.

Created On 28. 3. 2018 13:44:38

EMC measurement setup:

Fig. 1: EUT during evaluation of EMC test - Cond. emiss. (left) and Independent Radiated emissions (right)

Fig. 2: Front view of EUT (left) and schematic of EUT - front view (right)

Fig. 3: Detail of surge protection (left) and label from EUT (right)

EVALUATION

Page 2 of 5iLumTech by OMS, a.s.

Created On 28. 3. 2018 13:44:38

Fig. 4: Detail of used driver (left) and detail of used light souce (right)

Fig. 5: Graph of Peak and Average detec. of Cond.emiss.

EVALUATION

Page 3 of 5iLumTech by OMS, a.s.

Created On 28. 3. 2018 13:44:38

Fig. 7: Graph of Qpeak detector for Independent method of Rad. emiss.

EVALUATION

Page 4 of 5iLumTech by OMS, a.s.

Created On 28. 3. 2018 13:44:38

Fig. 6: Graph of QPeak and C-Average detec. of Cond.emiss.

Results from measurement Qpeak and C-Average data with 9dB margin for Cond.emiss.

Conclusion:

Tested EUT - Sagar 50W 4000K IP 66, pre-certification EMC test:

Used detector: Peak, Qpeak, Average, C-AverageVerdict: PASSED

Note: For Conducted emissions was used original power cord with 1 meter long.

EVALUATION

Frequency[MHz]

QPeak[dBµV]

Limit 55015Qp-..[dBµV]

Delta[dB]

C-Avg[dBµV]

Limit 55015Avg..[dBµV]

Delta[dB]

1 0.155 56.89 65.73 -8.84 36.68 55.73 --- 2 0.16 56.80 65.46 -8.66 32.46 55.46 ---

Page 5 of 5iLumTech by OMS, a.s.

Created On 28. 3. 2018 13:44:38

Page 1 / 7 of measurement report

Evaluation_ Sagar 50W 4000K

Electrical safety report

Measurement no.: 368 Date of measurement: 5.4.2018

Request ID: 3637 / R. Šalík Number of pages: 7

Tested luminaire: Sagar 50W

Product code:

Light source: 1xST19-050-0302(A) 7S9P MC

Driver specification: Sosen SS-50U-54, ClassI, IP67, SELV, Uout=32-54V, Iout=1050mA, Iout=50W,

LED driving current: 1050mA

Luminaire description: sample Power system: 50W

Testing laboratory: LIC, OMS s.r.o., Dojč 419, 906 02, Slovakia

Tested by: Pavol Pánik

Testing equipment: SPS ELECTRONIC - TESTER LG 1800B

Device Certificate number Manufacturer Date of calibration Cycle of calibration Serial & Part number

LG 1800B 17SU623 SPS electronic GmbH 12.9.2017 12 months 12022904

Measurement according to: STN EN 60598-1: 2014/Cor.2:2015

EN 60598-2-3:2002/AMD:2011

Realised measurements: INSULATION RESISTANCE

ELECTRIC STRENGTH

FUNCTIONALITY TEST

CONTINUITY OF PE WIRE

LEAKAGE CURRENT TEST

INSULATION RESISTANCE - Testing parameters: U =500 VDC, t=05,0 s, Rmin= 05,00 MΩ

CONTINUITY OF PE WIRE - Testing parameters: Umax=12 VAC, I=10 AAC, Rmax=500mΩ

FUNCTIONALITY TEST - Testing parameters:t=60,0 s, tg=10 s, Imin=00,0 AAC, Imax=1,0 AAC

ELECTRIC STRENGHT – t=05,0 s, U= 1,5kVAC (for SELV=500VAC)/ (2U +1000) x √2 = 2064V DC, Imax=3 mA

LEAKAGE CURRENT TEST - Testing parameters: Imax=3,5mA

Ambient temperature: 25°C Humidity: 45%

Measurement description: luminaire was measured in normal position

Page 2 / 7 of measurement report

Fig.1,2: Sagar 50W

Fig.3: used LED driver Fig.4: used overvoltage protection

Fig.5: marking of PCB Fig.6: used LED module

Page 3 / 7 of measurement report

Fig.5: label of Luminaire Fig.6: connection of luminaire

Test results: Sagar 50W - HV test only LED module

----------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------------------------

Program : EN 60598

Started on : 5. 4. 2018 10:20:31

Ended on : 5. 4. 2018 10:20:49

Tester : SPS

Total result : PASSED

Serial nr. : 343

# 1 H5 - High Voltage Test (AC/DC) - secondary side

Result : PASSED

Test time : 10 s

Ramp time : 2 s

Ramp down : not used

Ustart : 0 V

Unom : 500 V

Imin : 0 A

Imax : 2.99 mA

U type : AC

Safety ctrl. : start impulse

Ureal : 504.4 V

Ireal : 1.31 mA

Page 4 / 7 of measurement report

Test results: Sagar 50W - Electrical safety test

----------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------------------------

Program : EN 60598

Started on : 5. 4. 2018 10:26:09

Ended on : 5. 4. 2018 10:27:28

Tester : SPS

Total result : PASSED

Serial nr. : 345

# 1 CT - Continuity Test

Result : PASSED

Imin : 0 mA

Imax : 500 mA

Ireal : 0 A

# 2 PW - Protective Wire Test

Result : PASSED

Test time : 1 s

Imin : 10 A

Method : Resistance

Umax : 12 V

Rmin : 0 Ω

Rmax : 400 mΩ

Start mode : Start button

Ireal : 10.26 A

Rreal : 123 mΩ

Udrop real : 1.23 V

# 3 PW - Protective Wire Test

Result : PASSED

Page 5 / 7 of measurement report

Test time : 1 s

Imin : 10 A

Method : Resistance

Umax : 12 V

Rmin : 0 Ω

Rmax : 400 mΩ

Start mode : Start button

Ireal : 10.27 A

Rreal : 121 mΩ

Udrop real : 1.21 V

# 4 I5 - Insulation Test

Result : PASSED

Test time : 5 s

Ramp time : 0 s

Ramp down : not used

Ustart : 0 V

Unom : 500 V

Umin : NaN V

Umin : NaN V

Rmin : 4 MΩ

Safety ctrl. : start impulse

Ureal : 505.2 V

Rreal : 10 GΩ

# 5 L1 - Leakage Current Test

Result : PASSED

Test time : 1 s

Unom : 253 V

Imax : 1 mA

Ureal : 253.2 V

Ireal : 334 µA

# 6 H5 - High Voltage Test (AC/DC) - primary side ( L-PE)

Result : PASSED

Test time : 10 s

Ramp time : 2 s

Ramp down : not used

Ustart : 0 V

Unom : 1.5 kV

Imin : 0 A

Imax : 2.99 mA

U type : AC

Safety ctrl. : start impulse

Ureal : 1.504 kV

Ireal : 1.91 mA

Page 6 / 7 of measurement report

# 7 H5 - High Voltage Test (AC/DC) - primary side ( N-PE)

Result : PASSED

Test time : 10 s

Ramp time : 2 s

Ramp down : not used

Ustart : 0 V

Unom : 2.2 kV

Imin : 0 A

Imax : 2.99 mA

U type : AC

Safety ctrl. : start impulse

Ureal : 1.504 kV

Ireal : 1,91 mA

# 8 F1 - Function Test

Result : PASSED

Test time : 20 s

Good time : 19 s

Good time Ok : OK

Unom : 230 V

Fnom : 50 Hz

Imin : 0 A

Imax : 1 A

Page 7 / 7 of measurement report

Ireal : 228.6 mA

Ureal : 230 V

Conclusion:

Luminaire Sagar 50W - PASSED Electrical safety test.

In the future I recommend that the wires was be clamped by the spring terminals.

SAGAR 50W Streetlight

Created 10.04.2018

IP report

Tested luminaire/sample SAGAR Measurement date April 10, 2018 Report number 70 ID Request 3637 IP Request X6 Conducted by Miroslav Mihok Applicant Radoslav Šalík

Test specification European Standard: EN 60598-1 IP test: Normal conditions

Testing equipment used JET NOZZLE TESTER – MODEL 6990

Test Description

IP test (normal condition) a) The water for the tests shall be ata temperature of 15°C ± 10°C.b) Ambient temperature inside the testingroom is in range 10-30°C.After completion of the tests inspectionshall show:- no trace of water on current-carryingparts or SELV parts or on insulationwhere it could become a hazard for theuser or surroundings,- no trace of water entered in any part ofa watertight or pressure watertightluminaire.

Measurement setup:

SAGAR 50W Streetlight

Created 10.04.2018

SAGAR 50W Streetlight

Created 10.04.2018

Result summary:

SAGAR 50W Streetlight

Created 10.04.2018

Conclusion/Comment of IP test report:

Tested luminaire SAGAR passed successfully the IP test (normal condition).

OMS, a.s.Dojč 419, 906 02 Dojč, [email protected].: +421 34 694 0811Fax: +421 34 694 0888

www.omslighting.com

BOOK OF MEASSUREMENTS 04/2018