board facility important connect · simultaneously press and release the 2 transmitter buttons...

2
NOTE: If is a Digital limit switch System, after programming the “Default Settings” topic, it is necessary to memorize the route. Otherwise, the board will operate with a minimum of 100 pulses. IMPORTANT Once the board has been installed in the operator system, it is necessary to memorize the path for correct operation. In case of limit switch, whenever the power is switched on (first command after power failure), the motor will be activated (pulsing torque mode) until the mechanical closing stop is found. If this is done, the operation will be normal. In case of limit switch, whenever it is necessary to reverse the motor rotation (black and red wires), the boardmust be switched off. After the first command after reconnecting it, the operating procedure will be identical to the previous topic. It is not necessary to reverse the position of the encoder because the board corrects the position automatically. Reversing the direction of rotation of the motor is necessary to adjust the operation of the board to the position of the gate. Failure to observe this item may result in improper operation of the operator by reversing the logic operating for controls and photocell. In case of limit switch, when storing the course or near the limit switch, the engine will be running in pulsating torque mode, ie the engine will be on and off continuously. The maximum pause time is 4 minutes. In case of limit switch, in equipment with little force to learn the course, we must abort the process and enter the programming to increase the pulsating torque force in the memorization (simultaneously press the 2 buttons of the transmitter for 8 Times). To perform any of the programming steps on the board, there is no need to record the 2 buttons on the transmitter. With just one of the recorded keys, we can access all the functions of the electronics. When the PROG jumper is open, the GRV button functions as the gate open / close command. 3. TRANSMITTER RECORD The board can record up to 160 different and independent buttons. For transmitter record: 1. The gate must be stopped and not be timed for for automatic closing. 1. Close the jumper PROG. The green SN led must be dim. 2. Press and hold the transmitter button. The green SN led should flash. 3. Press and release the GRV button, and check the SN led: - If the SN led flashes 1 time: Recorded the transmitter button. - If the SN led flashes 2 times: The transmitter button is already recorded. - If the SN led flashes 3 times: The memory is full. 4. Release transmitter button. 5. To record other transmitter buttons, continue from step 3. 6. To end the operation, open the jumper PROG. NOTE: In User Mode (open PROG jumper), the transmitter commands are only for gate opening / closing operation. In this mode, the control panel will not accept a command when the 2 transmitter buttons are pressed simultaneously. 4. SELECTING DIGITAL OR ANALOGUE COURSE SYSTEM 1. The gate must be stopped and not timed for automatic closing. 2. Manage the PROG jumper open. 3. Select the limit switch option via the FC jumper: FC Open: Limit switch Analog. FC Closed: Limit switch Digital. 4. After selecting the limit switch system, it will be necessary to memorize the automatic route. Otherwise, if Digital limit switchis selected, the board will operate with a minimum of 100 pulses or, if Analog limit switch is selected, the opening / closing time will be 120 sec. 5. AUTOMATIC BOARD PROGRAMMING (COMPLETE CYCLE) 1. The gate must be open. 2. Close the PROG jumper. The green SN led must be on. 3. Simultaneously press and release the 2 transmitter buttons (recorded) once. The SN led will flash when the buttons are released. After 5 seconds, the board will enter the automatic programming mode. 4. The gate will close until the mechanical stop FCF (Closing limit switch) or the two buttons of the transmitter are pressed simultaneously. After 1 second, the gate will open by memorizing the route until you find the mechanical stop FCA (Opening limit switch) or if the two buttons on the transmitter are pressed simultaneously. NOTE: In the case of Digital limit switch, in the course of Memorizing the engine will operate in Pulsating Torque mode. 5. The SN led will begin to flash as a clock every 1 second and wait for the programming of the Automatic or Semi-Automatic Mode. NOTE: If both buttons of the transmitter are pressed simultaneously, the Pause setting will be canceled and you will go to the next step, leaving the last setting recorded. Automatic Mode: In this mode, after it is opened, the gate will close automatically after a programmed pause time. When the SN led: Slow flashing 1 time (2 sec.): Force minimum. Fast flashing: Strength adjustment between the minimum and maximum. Slow flashing 1 time (2 sec.): Maximum force. To go back and select new setting (step 6): Simultaneously press and release the 2 buttons on the transmitter. To end programming: Simultaneously press and release the 2 transmitter buttons or open the PROG jumper. 9.ADJUSTING THE OPENING/ CLOSING POSITION OF THE LIMIT SWITCH This type of adjustment allows you to gradually advance or rewind the limit switch, independent of the opening and closing stop. 1. The gate must be stopped and not timed for automatic closing. 2. Selected Digital limit switch (FC jumper closed). 3. The gate path must be memorized. Otherwise, the function will be canceled. 4. Close the PROG jumper. The green SN led must be dim. 5. Simultaneously press and release the 2 buttons on the transmitter (recorded) 6 times. The SN led will flash each time the buttons are released. Waint 5 seconds. 6. Next, the SN led will go off and the board will wait for the limit switch position programmed. 7. To adjust the position of the closing limit switch, press and release the GVR button. The SN ledwill flash once. NOTE: If the REC button is not pressed, the adjustment of the limit switch position will be opening. 8. Adjusting the position of the limit switch (setting up to 10 pulses) 1 pulse back off of the limit switch position: Press the left button of the transmitter until find the desired setting. Advance 1 pulse of the limit switch position: Pulse the right button on the transmitter until find the desired setting. To go back and select new setting (step 6): Simultaneously press and release the 2 buttons on the transmitter. End programming: Simultaneously press and release the 2 transmitter buttons or open the PROG jumper. 10.ADJUSTING THE OPENING/ CLOSING INDEPENDENT LIMIT SWITCH The limit switch is the distance that is missing to reach the mechanical stop. The board will continuosly monitor the position of the gate and when it reaches this limit, the pulsating torque mode is turned on to slow down and to smoothly stop. . 1. The gate must be stopped and not timed for automatic closing. 2. Selected Digital limit switch (FC jumper closed). 3. The gate path must be memorized. Otherwise, the function will be canceled. 4. Close the PROG jumper. The green SN led must be dim. 5. Simultaneously press and release the 2 buttons on the transmitter (recorded) 7 times. The SN led will flash each time the buttons are released. Wait 5 seconds. 6. Next, the SN led will turn off and the board will wait for the limit switch programmed. 7. Adjusting the limit and check the SN led. The function has up to 5 adjustment levels: 8. To adjust the position of the closing limit switch, press and release the GRV button. The SN led wil flash once. NOTE: If the GRV button is not pressed, the li mit switch setting will be adjusted for the opening. Decrease limit switch distance: Press the left button of the transmitter until the desired setting is reached. Increasing the limit switch distance: Press the right button of the transmitter until you find the desired setting. End programming: Simultaneously press and release the 2 transmitter buttons or open PROG jumper. When the LED SN: • SN led slow flashing 1 time (2 sec): minimum limit. SN led flashes fast: between minimum and maximum limit. SN ledflashes slow 1 time (2 sec): maximum limit. Divider adjustment index (5 levels): 04, 08, 16, 32 and 64 Exemplo: Memorized course by the board = 1000 pulses. Limit switch selected = Divider 04. Calculation: 1000 pulses / 04 = 250 pulses remaining. Then, when 250 pulses are missing to reach the mechanical stop, the board will reduce the speed in pulsating torque so that the gate gently touches the stop. NOTE: The higher the divider, the lower the speed reduction distance, the gate will be closer to the mechanical stop of the limit switch. 11. AJUSTING OF THE TORQUE FORCE PULSING INDEPENDENT FOR OPENING AND CLOSING MEMORIZED OF THE COURSE. To set the pause time, press and hold the right button of the transmitter and count the seconds through the clock or SN led. After counting the pause time, the transmitter button must be released. Semi-Automatic Mode: In this mode, after opening the gate, a new command is required for closing. To program, press and release the left button of the transmitter. 6. The gate will start to cycle in a continuous close and open and wait for the programming of the Motor Force (Electronic Clutch). This force must be checked by trying to hold the gate. To reduce or increase the force exerted by the motor, proceed as follows: Decrease Strength: Press and release the left button of the transmitter and check the force again. If necessary, you can press and release the left button slowly until you find the desired setting. Increase Strength: Press and release the right button of the transmitter and check the force again. If necessary, you can press and release the right button momentarily until you find the desired setting. NOTE: At this stage, the gate will not reach the mechanical stop (opening / closing), but until the point of the course where there will be the change from high speed to low. This transition point is programmable (see “Limit switch Adjustment”). 7. When the desired force is chosen, the 2 transmitter buttons must be pressed and released simultaneously, and then the motor will be turned off and the selected force will be recorded in the memory. NOTE: At this stage, if the PROG jumper is opened, the motor will shut down and will not record the force setting, keeping the previous record. 8. To complete the Automatic Programming (Full Cycle), open the PROG jumper. NOTE: Automatic Programming (Full Cycle) can be terminated at any time in the plant configuration cycle, just by opening the PROG jumper. During the programming process, only the transmitter recorded in memory and started programming can interfere with or change the configuration parameters. To change the programming of the control panel with another recorded transmitter, you must restart the entire programming process. 6. AUTOMATIC PROGRAMMING OF BOARD (FROM PAUSE ADJUSTMENT) 1. Close the PROG jumper. The green led SN should be dim. 2. Simultaneously press and release the 2 buttons on the transmitter (recorded) 2 times. The LED SN flashes each time the buttons are released. After 5 seconds, the board will enter the automatic programming mode (see from step 5 of the previous topic - Automatic plant programming [full cycle]). 7. DELETE ALL THE TRANSMITTER MEMORY. 1. The gate must be stopped and not timed for automatic closing. 2. Close the PROG jumper. The green led SN should be dim. 3. Simultaneously press and release the two buttons on the transmitter (recorded) 3 times. The SN led will blink every time the buttons are released. Wait 5 seconds. 4. Next, the SN led will be on awaiting confirmation for the exclusion of the transmitters or the cancellation of the operation. To cancel operation: Press and release the left button of the transmitter. The SN led will be weak again. Deleting all transmitters: Press and release the right button on the transmitter. The SN led will flash 3 times indicating that you have cleared all transmitters. 5. Open the PROG jumper. 8. SETTING TORQUE FORCE PULSATING INDEPENDENT FOR OPENING AND CLOSING The board will be pulsing the motor, ie it will be turned off and turned on quickly so that it has low speed force. Depending on the weight of the gate, the torquemust be adjusted to move it. 1. The gate must be stopped and not timed for automatic closing. 2. Selected Digital limit switch (FC jumper closed). 3. The gate path must be memorized. Otherwise, the function will be canceled. 4. Close the PROG jumper. The green SN led must be dim. 5. Simultaneously press and release the 2 buttons on the transmitter (recorded) 5 times. The SN led will flash each time the buttons are released. Wait 5 second. 6. Next, the SN led will turn off and the board will wait for the setting of the pulsating torque force setting. 7. To adjust the pulsing torque fosse in the clsingcycle, must press GRV.The SN led will flash 1 time. NOTE: If the GRV button is not pressed, the force setting of the pulsating torque will be for the opening cycle. 8. Adjust the force and check the SN led. The function has up to 32 adjustment levels: Decrease the force of the pulsating torque: Press the left button of the transmitter until the desired setting is reached. Increase the force of the pulsating torque: Press the right button of the transmitter until you find the desired setting. IMPORTANT Please read this manual carefully for proper use and to ensure proper installation of the automation. All data referenced in this manual is for information only. Any technical changes to the product are reserved without prior notice. QUICK REFERENCE GUIDE TO PROGRAMMING INDEXES Simultaneously press the 2 buttons on the transmitter (the number of times indicated below). At least one of the buttons must be recorded: 1 time: Automatic board Programming (full cycle). 2 times: Automatic programming of the board starting with the Pause setting. 3 times: Deleting all transmitters from memory. 4 times: Factory default settings (Reset). 5 times: Adjusting the pulsating torque (opening / closing). 6 times: Adjustment of the limit position (opening / closing). 7 times: Limit switch setting (opening / closing). 8 times: Setting the pulsating torque in the memory (opening / closing). 9 times: Setting the brake operating time. 10 times: Select transmitter code type (fixed / moving). 11 times: Select relay module type (latch, garage or signal light). 1. MAIN CHARACTERISTICS • Digital / Analog End-of-Course System. RF receiver module 433.92 MHz. • Rolling Code up to 160 different and independent or fixed code transmitters button rolling. • Automatic memory of the course. Selecting the automatic or semiautomatic mode via the transmitter. Setting the pause time for automatic closing via the transmitter (maximum = 4.0 min). • Adjusting the electronic clutch (force) through the transmitter. Command to delete all transmitters through the transmitter. • Command to configure the board (factory default) via the transmitter. Output for relay module, Garage Light, Signal or Lock. Input for external device selector as programmer or bluetooth for access and also programmer. Photocell input. RF receiver socket. Pushbutton input. Input for external device selector as programmer or bluetooth for access and also programmer. 2. DEFAULT SETTINGS (FACTORY DEFAULT) Strength = Maximum. Closing = Semiautomatic. • Pulse torque (aperture) = Level 8. • Pulsing torque (closing) = Level 5. Pulse force in the memorization (opening)= Level 11. • Pulse torque in memory (closing) = Level 7. Limiter system = Depends on the FC jumper setting: - If jumper FC open = Analog limit switch, then: * Brake time (opening / closing) = 200 msec. * Time A / F = 120sec. - If jumper FC closed End of digital course, then: *Brake time (open / close) = Off. *Track = 0. Limit switch = Course / 16 • Retraction FCA = 2 pulses. Recall FCF = 0 pulses. Relay module output = Latch. To return to the factory default settings: 1. The gate must be stopped and not be timed for automatic closing. 2. In the FC jumper, select the limit switch: Analog (FC open) or Digital (FC closed). 3. Close the PROG jumper. The green led SN should be dimly lit. 4. Press and release, simultaneously the 2 transmitter button (recorded) 4 times. The LED SN flashes each time the buttons are released. Wait 5 seconds. 5. The LED SNflashes 4 timesconfirming the reset of the board. 6. Open the jumper PROG. BOARD FACILITY CONNECT TECHNICAL MANUAL WARNING Do not operate the equipment without first reading the instructions manual. P04640 - Rev. 0

Upload: others

Post on 12-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BOARD FACILITY IMPORTANT CONNECT · Simultaneously press and release the 2 transmitter buttons (recorded) once. The SN led will flash when the buttons are released. After 5 seconds,

NOTE: If is a Digital limit switch System, after programming the “Default Settings” topic, it is necessary to memorize the route. Otherwise, the board will operate with a minimum of 100 pulses.

IMPORTANT• Once the board has been installed in the operator

system, it is necessary to memorize the path for correct operation.

• In case of limit switch, whenever the power is switched on (first command after power failure), the motor will be activated (pulsing torque mode) until the mechanical closing stop is found. If this is done, the operation will be normal.

• In case of limit switch, whenever it is necessary to reverse the motor rotation (black and red wires), the boardmust be switched off. After the first command after reconnecting it, the operating procedure will be identical to the previous topic. It is not necessary to reverse the position of the encoder because the board corrects the position automatically. Reversing the direction of rotation of the motor is necessary to adjust the operation of the board to the position of the gate. Failure to observe this item may result in improper operation of the operator by reversing the logic operating for controls and photocell.

• In case of limit switch, when storing the course or near the limit switch, the engine will be running in pulsating torque mode, ie the engine will be on and off continuously.

• The maximum pause time is 4 minutes.• In case of limit switch, in equipment with little

force to learn the course, we must abort the process and enter the programming to increase the pulsating torque force in the memorization (simultaneously press the 2 buttons of the transmitter for 8 Times).

• To perform any of the programming steps on the board, there is no need to record the 2 buttons on the transmitter. With just one of the recorded keys, we can access all the functions of the electronics.

• When the PROG jumper is open, the GRV button functions as the gate open / close command.

3. TRANSMITTER RECORDThe board can record up to 160 different and independent buttons.For transmitter record:1. The gate must be stopped and not be timed for for

automatic closing.1. Close the jumper PROG. The green SN led must be

dim.2. Press and hold the transmitter button. The green SN

led should flash.3. Press and release the GRV button, and check the

SN led:- If the SN led flashes 1 time: Recorded the transmitter button.- If the SN led flashes 2 times: The transmitter button is already recorded.- If the SN led flashes 3 times: The memory is full.

4. Release transmitter button.5. To record other transmitter buttons, continue from

step 3.6. To end the operation, open the jumper PROG.

NOTE: In User Mode (open PROG jumper), the transmitter commands are only for gate opening / closing operation. In this mode, the control panel will not accept a command when the 2 transmitter buttons are pressed simultaneously.

4. SELECTING DIGITAL OR ANALOGUE COURSE SYSTEM1. The gate must be stopped and not timed for

automatic closing.2. Manage the PROG jumper open.3. Select the limit switch option via the FC jumper:

FC Open: Limit switch Analog.FC Closed: Limit switch Digital.

4. After selecting the limit switch system, it will be necessary to memorize the automatic route. Otherwise, if Digital limit switchis selected, the board will operate with a minimum of 100 pulses or, if Analog limit switch is selected, the opening / closing time will be 120 sec.

5. AUTOMATIC BOARD PROGRAMMING (COMPLETE CYCLE)1. The gate must be open.2. Close the PROG jumper. The green SN led must be on.3. Simultaneously press and release the 2 transmitter

buttons (recorded) once. The SN led will flash when the buttons are released. After 5 seconds, the board will enter the automatic programming mode.

4. The gate will close until the mechanical stop FCF (Closing limit switch) or the two buttons of the transmitter are pressed simultaneously. After 1 second, the gate will open by memorizing the route until you find the mechanical stop FCA (Opening limit switch) or if the two buttons on the transmitter are pressed simultaneously.

NOTE: In the case of Digital limit switch, in the course of Memorizing the engine will operate in Pulsating Torque mode.

5. The SN led will begin to flash as a clock every 1 second and wait for the programming of the Automatic or Semi-Automatic Mode.

NOTE: If both buttons of the transmitter are pressed simultaneously, the Pause setting will be canceled and you will go to the next step, leaving the last setting recorded.

Automatic Mode: In this mode, after it is opened, the gate will close automatically after a programmed pause time.

When the SN led:• Slow flashing 1 time (2 sec.): Force minimum.• Fast flashing: Strength adjustment between the

minimum and maximum.• Slow flashing 1 time (2 sec.): Maximum force.

To go back and select new setting (step 6): Simultaneously press and release the 2 buttons on the transmitter.To end programming: Simultaneously press and release the 2 transmitter buttons or open the PROG jumper.

9.ADJUSTING THE OPENING/ CLOSING POSITION OF THE LIMIT SWITCH

This type of adjustment allows you to gradually advance or rewind the limit switch, independent of the opening and closing stop.

1. The gate must be stopped and not timed for automatic closing.

2. Selected Digital limit switch (FC jumper closed). 3. The gate path must be memorized. Otherwise, the

function will be canceled. 4. Close the PROG jumper. The green SN led must

be dim. 5. Simultaneously press and release the 2 buttons

on the transmitter (recorded) 6 times. The SN led will flash each time the buttons are released. Waint 5 seconds.

6. Next, the SN led will go off and the board will wait for the limit switch position programmed.

7. To adjust the position of the closing limit switch, press and release the GVR button. The SN ledwill flash once.

NOTE: If the REC button is not pressed, the adjustment of the limit switch position will be opening.

8. Adjusting the position of the limit switch (setting up to 10 pulses)

1 pulse back off of the limit switch position: Press the left button of the transmitter until find the desired setting.

Advance 1 pulse of the limit switch position: Pulse the right button on the transmitter until find the desired setting.

To go back and select new setting (step 6): Simultaneously press and release the 2 buttons on the transmitter.

End programming: Simultaneously press and release the 2 transmitter buttons or open the PROG jumper.

10.ADJUSTING THE OPENING/ CLOSING INDEPENDENT LIMIT SWITCHThe limit switch is the distance that is missing to reach the mechanical stop. The board will continuosly monitor the position of the gate and when it reaches this limit, the pulsating torque mode is turned on to slow down and to smoothly stop. .1. The gate must be stopped and not timed for

automatic closing. 2. Selected Digital limit switch (FC jumper closed).3. The gate path must be memorized. Otherwise, the

function will be canceled.4. Close the PROG jumper. The green SN led must be

dim. 5. Simultaneously press and release the 2 buttons on

the transmitter (recorded) 7 times. The SN led will flash each time the buttons are released. Wait 5 seconds.

6. Next, the SN led will turn off and the board will wait for the limit switch programmed.

7. Adjusting the limit and check the SN led. The function has up to 5 adjustment levels:

8. To adjust the position of the closing limit switch, press and release the GRV button. The SN led wil flash once.

NOTE: If the GRV button is not pressed, the li mit switch setting will be adjusted for the opening.

Decrease limit switch distance: Press the left button of the transmitter until the desired setting is reached.

Increasing the limit switch distance: Press the right button of the transmitter until you find the desired setting.

End programming: Simultaneously press and release the 2 transmitter buttons or open PROG jumper.

When the LED SN:• SN led slow flashing 1 time (2 sec): minimum

limit.• SN led flashes fast: between minimum and

maximum limit.• SN ledflashes slow 1 time (2 sec): maximum limit.

Divider adjustment index (5 levels): 04, 08, 16, 32 and 64Exemplo:• Memorized course by the board = 1000 pulses.• Limit switch selected = Divider 04.• Calculation: 1000 pulses / 04 = 250 pulses remaining.• Then, when 250 pulses are missing to reach the

mechanical stop, the board will reduce the speed in pulsating torque so that the gate gently touches the stop.

NOTE: The higher the divider, the lower the speed reduction distance, the gate will be closer to the mechanical stop of the limit switch.

11. AJUSTING OF THE TORQUE FORCE PULSING INDEPENDENT FOR OPENING AND CLOSING MEMORIZED OF THE COURSE.

To set the pause time, press and hold the right button of the transmitter and count the seconds through the clock or SN led. After counting the pause time, the transmitter button must be released.Semi-Automatic Mode: In this mode, after opening the gate, a new command is required for closing.To program, press and release the left button of the transmitter.

6. The gate will start to cycle in a continuous close and open and wait for the programming of the Motor Force (Electronic Clutch). This force must be checked by trying to hold the gate. To reduce or increase the force exerted by the motor, proceed as follows:

Decrease Strength: Press and release the left button of the transmitter and check the force again. If necessary, you can press and release the left button slowly until you find the desired setting.Increase Strength: Press and release the right button of the transmitter and check the force again. If necessary, you can press and release the right button momentarily until you find the desired setting.

NOTE: At this stage, the gate will not reach the mechanical stop (opening / closing), but until the point of the course where there will be the change from high speed to low. This transition point is programmable (see “Limit switch Adjustment”).

7. When the desired force is chosen, the 2 transmitter buttons must be pressed and released simultaneously, and then the motor will be turned off and the selected force will be recorded in the memory.

NOTE: At this stage, if the PROG jumper is opened, the motor will shut down and will not record the force setting, keeping the previous record.

8. To complete the Automatic Programming (Full Cycle), open the PROG jumper.

NOTE: Automatic Programming (Full Cycle) can be terminated at any time in the plant configuration cycle, just by opening the PROG jumper.During the programming process, only the transmitter recorded in memory and started programming can interfere with or change the configuration parameters. To change the programming of the control panel with another recorded transmitter, you must restart the entire programming process.

6. AUTOMATIC PROGRAMMING OF BOARD (FROM PAUSE ADJUSTMENT)1. Close the PROG jumper. The green led SN should

be dim.2. Simultaneously press and release the 2 buttons

on the transmitter (recorded) 2 times. The LED SN flashes each time the buttons are released. After 5 seconds, the board will enter the automatic programming mode (see from step 5 of the previous topic - Automatic plant programming [full cycle]).

7. DELETE ALL THE TRANSMITTER MEMORY.1. The gate must be stopped and not timed for

automatic closing. 2. Close the PROG jumper. The green led SN should

be dim.3. Simultaneously press and release the two buttons

on the transmitter (recorded) 3 times. The SN led will blink every time the buttons are released. Wait 5 seconds.

4. Next, the SN led will be on awaiting confirmation for the exclusion of the transmitters or the cancellation of the operation.

To cancel operation: Press and release the left button of the transmitter. The SN led will be weak again.Deleting all transmitters: Press and release the right button on the transmitter. The SN led will flash 3 times indicating that you have cleared all transmitters.

5. Open the PROG jumper.

8. SETTING TORQUE FORCE PULSATING INDEPENDENT FOR OPENING AND CLOSINGThe board will be pulsing the motor, ie it will be turned off and turned on quickly so that it has low speed force.Depending on the weight of the gate, the torquemust be adjusted to move it.1. The gate must be stopped and not timed for

automatic closing.2. Selected Digital limit switch (FC jumper closed).3. The gate path must be memorized. Otherwise, the

function will be canceled.4. Close the PROG jumper. The green SN led must

be dim.5. Simultaneously press and release the 2 buttons

on the transmitter (recorded) 5 times. The SN led will flash each time the buttons are released. Wait 5 second.

6. Next, the SN led will turn off and the board will wait for the setting of the pulsating torque force setting.

7. To adjust the pulsing torque fosse in the clsingcycle, must press GRV.The SN led will flash 1 time.

NOTE: If the GRV button is not pressed, the force setting of the pulsating torque will be for the opening cycle.

8. Adjust the force and check the SN led. The function has up to 32 adjustment levels:

Decrease the force of the pulsating torque: Press the left button of the transmitter until the desired setting is reached.Increase the force of the pulsating torque: Press the right button of the transmitter until you find the desired setting.

IMPORTANT

Please read this manual carefully for proper use and to ensure proper installation of the automation. All data referenced in this manual is for information only. Any technical changes to the product are reserved without prior notice.

QUICK REFERENCE GUIDE TO PROGRAMMING INDEXESSimultaneously press the 2 buttons on the transmitter (the number of times indicated below). At least one of the buttons must be recorded:1 time: Automatic board Programming (full cycle).2 times: Automatic programming of the board starting with the Pause setting.3 times: Deleting all transmitters from memory.4 times: Factory default settings (Reset).5 times: Adjusting the pulsating torque (opening / closing).6 times: Adjustment of the limit position (opening / closing).7 times: Limit switch setting (opening / closing).8 times: Setting the pulsating torque in the memory (opening / closing).9 times: Setting the brake operating time.10 times: Select transmitter code type (fixed / moving).11 times: Select relay module type (latch, garage or signal light).

1. MAIN CHARACTERISTICS• Digital / Analog End-of-Course System.• RF receiver module 433.92 MHz.• Rolling Code up to 160 different and independent or

fixed code transmitters button rolling.• Automatic memory of the course.• Selecting the automatic or semiautomatic mode via

the transmitter.• Setting the pause time for automatic closing via the

transmitter (maximum = 4.0 min).• Adjusting the electronic clutch (force) through the

transmitter.• Command to delete all transmitters through the

transmitter.• Command to configure the board (factory default)

via the transmitter.• Output for relay module, Garage Light, Signal or Lock. • Input for external device selector as programmer or

bluetooth for access and also programmer.• Photocell input.• RF receiver socket.• Pushbutton input.• Input for external device selector as programmer or

bluetooth for access and also programmer.

2. DEFAULT SETTINGS (FACTORY DEFAULT)• Strength = Maximum.• Closing = Semiautomatic.• Pulse torque (aperture) = Level 8.• Pulsing torque (closing) = Level 5.• Pulse force in the memorization (opening)= Level 11.• Pulse torque in memory (closing) = Level 7.• Limiter system = Depends on the FC jumper setting:

- If jumper FC open = Analog limit switch, then:* Brake time (opening / closing) = 200 msec.* Time A / F = 120sec.

- If jumper FC closed End of digital course, then:*Brake time (open / close) = Off.*Track = 0.

• Limit switch = Course / 16• Retraction FCA = 2 pulses.• Recall FCF = 0 pulses.• Relay module output = Latch.

To return to the factory default settings:1. The gate must be stopped and not be timed for

automatic closing.2. In the FC jumper, select the limit switch: Analog (FC

open) or Digital (FC closed).3. Close the PROG jumper. The green led SN should

be dimly lit.4. Press and release, simultaneously the 2 transmitter

button (recorded) 4 times. The LED SN flashes each time the buttons are released. Wait 5 seconds.

5. The LED SNflashes 4 timesconfirming the reset of the board.

6. Open the jumper PROG.

BOARD

FACILITYCONNECT

TECHNICAL MANUAL

WARNINGDo not operate the equipment without first reading the instructions manual.

P04640 - Rev. 0

Page 2: BOARD FACILITY IMPORTANT CONNECT · Simultaneously press and release the 2 transmitter buttons (recorded) once. The SN led will flash when the buttons are released. After 5 seconds,

of flash on the led. Each flash represents 10 seconds for the garage light.

5. Open jumper PROG.

15. PROGRAMMER

It has the purpose of executing the programming of internal functions independently and faster.

Button Function:

= Advance function; = Back in function;

= Increase the value of the function.= Decrementar o valor da função.

= Both buttons pressed simultaneously to start motor.

Board to be connected, the programmer displays the messages of Figures 1, 2 and 3 in sequence.

ADVANCE FUNCTION

BACK FUNCTION

INCREASE THE VALUE OF THE FUNCTION

DECREASE VALUE OF THE FUNCTION

COMMAND TO OPEN OR CLOSE THE GATE

Press and release both buttons simultaneously and slowly to start the engine and observe the status of the gate.

SCREEN INFORMATION

Displays the gate status information, sensors, and transmitter position that released gate access.

TRANSMITTER

NOTE: : In attempt to program the type of transmitter with the gate in moviment, the function will be canceled and an audible alarm will be activated.

RECORD TRANSMITTER

1. It is not necessary to close the panel’s PROG jumper.

2. Press and hold the transmitter button.3. The indicator s on the screen will signal the

presence of the transmitter.

This type of adjustment is identical to “Independent Piston Torque Adjustment for Opening and Closing”, but it is valid only in the event of course.For this setting, you must simultaneously press and release the 2 buttons on the transmitter (recorded) 8 times.

12.TRIGGER TIME OF THE BRAKE INDEPENDENT FOR OPENING AND CLOSING

This type of adjustment allows the electronic brake to be turned off.

1. The gate must be stopped and not timed for automatic closing.

2. Close the PROG jumper. The green SN led must be dim.

3. Press and release simultaneously the 2 buttons on the transmitter (recorded) 9 times. The SN led will flash each time the buttons are released. Wait 5 seconds.

4. Then the SN led will turn off and wait for the limit switch position to be programmed.

5. To select the brake adjustment at closing, press and release the GRV button. The SN led will flash once.

NOTE: In Case of the GRV button not pressed, the adjustment of the brake will be open.

6. Adjusting the brake. The function has up to 11 adjustment levels.

Decrease the brake time (SN LED flashes quickly) or off (SN LED flashes slow): Press the left button of the transmitter until you find the desired setting.Increase the brake time (SN LED flashes quickly): Press the right of the transmitter until find the desired setting.

End of programmer: Open PROG jumper.

13. SELECT THE TYPE OF TRANSMITTER FIXE CODE OR ROLING

1. The gate must be stopped and not timed por automatic closing.

2. Close the PROG jumper. The green SN led must be dim.

3. Simultaneously press and release the two buttons on the transmitter (recorded) 10 times. The SN led will flash each time the buttons are released. Wait 5 seconds.

4. Next, the led SN will be on waiting for the configuration of the type of transmitter.

To transmitter fixed code: Press and release the left button of the transmitter.For rolling code transmitter: Press and release the right button of the transmitter.

5. Open the PROG jumper.

End programming: Simultaneously press and release the 2 transmitter buttons or open the PROG jumper. After the transmitter type is selected, the memory will be deleted.

14. SELECTING THE RELAY MODULE FUNCTION

1. The gate must be stopped and not timed for automatic closing.Fechar o jumper PROG.

2. Close the PROG jumper. The green led SN should be dim.

3. Simultaneously press and release the two buttons on the transmitter (recorded) 11 times. The SN led will flash each time the buttons are released. Wait 5 seconds.

4. Next, the SN LED will flash in the clock mode and wait for the configuration of the relay module function.

To lock: Press and release the right and left buttons of the transmitter simultaneously.For signalman: Press and release the left button of the transmitter.For garage light: Press and hold the right button on the transmitter and count the number

4. Press and release the + button, and the g indicator on the screen will indicate that you have recorded.

5. The transmitter counter recorded n: on the screen will be updated.

6. Remove transmitter button, and the s indicator on the screen will be erased.To record other buttons, repeat from item 2.

MEMORY COURSE

The board will enter the closing cycle until the limit switch is found, and after 1 sec., Initializes the opening cycle, storing the encoder time or pulses until the limit switch is opened.

CLOSING RAMP

NOTE: : In attempt to program the closing ramp with the gate in moviment, the function will be canceled and an audible alarm will be activated.

OPENING RAMP

NOTE: In attempt to program the opening ramp with the gate in moviment, the function will be canceled and an audible alarm will be activated.

CLOSING RAMP TORQUE

OPENING RAMP TORQUE

CLOSING MEMORIZED TORQUE

OPENING MEMORIZED TORQUE

FORCE

Adjust the electronic clutch with the gate moving or stopped, up to 14 levels.

PAUSE

Time adjustment for automatic closing when the gate find the FCA opening limit switch.

LOCK

At the opening cycle command, if the lock is enabled [S] and the module connected, it will be activated and after 1 sec. The board will start the engine and after 2 sec. The lock will be turned off.

GARAGE LIGHT / TRAFFIC LIGHT

• For garage light, set time in xxx seconds, and when the board finds the limit switch sensor FCF, it will timer for shutdown.

• For traffic light, set the time to 000 seconds, and when theboard finds the limit switch sensor FCF, it will shut down.

• To activate the garage light or traffic light functions, disable the lock module [N].

OPENING BRAKE TIME

CLOSING BRAKE TIME

OPENING ADJUST LIMIT SWITCH POSITION

CLOSING ADJUST LIMIT SWITCH POSITION

RESTORE FACTORY DEFAULT

DELETE TRANSMITTER

NOTE: In attempt to program the type of transmitter with the gate in movimente, the function will be canceled and an audible alarm will be activated.

127 or 220V(50 / 60 Hz)

FCA

FCF

Capacitorstarting motor

Separated Receiver

Buttonhole

Optional Module

Light, Signal, Lock

Analog Limit

Switch

Dig

ital L

imit

Switc

h

RF Receiver 433,92 MHz

Button for TX recording and ajusting some

functions

Photocell

Limit switch selection jumper

Programming Jumper

Motor

Yellow

Red/Black

Black/Red