Contact us for technical advice, free designs or detailed quotationBN Thermic Ltd34 Stephenson WayThree BridgesCrawleyWest SussexRH10 1TN

Tel 01293 547361Fax 01293 531432Email [email protected] www.bnthermic.co.uk

2013- 2014

Air Curtains

Fan Convector Heater

Terrace Heater

Touch-Screen Thermostat range

Underfloor Heating Foil Mats

Product GuideValid from 1st October 2013

Wireless Controls

new

new

new

specialists in

commercial and industrial heating

underfloor heating

and heating cables

new

new

new

Catalogue2013_Cover_unpriced.indd 1 30/08/2013 11:42

Page 2: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432

Catalogue Valid from 1st October 2013

Commercial and Industrial, Electric Heating and Controls

SCH Suspended Ceiling Heaters 26CHS SuspendedCeilingMulti-HeaterSystem28800 Series Over door/High Level Heaters 30HCA Air Curtains 32EFC Fan Convector 33 RH Recessed Ceiling Heaters 34OUH Industrial Unit Heaters 36DSU DestratificationUnits39 WHE CompactHeavyDutyWallHeaters40

Fan Assisted Heaters

26-40

HWP PatioHeaters46ETH Terrace Heaters 48HB HalogenWorkshopHeater49HN Halogen Heaters 50RL ReplacementHalogenLamps 53CH CeramicHeaters54RP Radiant Ceiling Panels 56 ESP RadiantCassettes58

Radiant Heaters

46-61

GP SelfRegulatingCableforGutters&Downpipes18ERC SnowandIceMeltingHeatingMats20CRJ SelfRegulatingCable22PW Pre-terminatedCables24

Pipe Freeze

& Gutter Protection 18-24

MD MirrorDemisterPads17

Mirror Demisters

17

CONTROLS HardCaseTamperproofThermostats 62 Timers64 Contactors 64 Thermostats 65 ShortwaveHeaterControls 68

Controls

62-69

M Series UnderfloorHeatingMats4EHC UnderfloorHeatingCables6F Series UnderfloorFoilMats8LH UnderfloorHeatingFilms10LH-K UnderfloorHeatingFilms12Accs UnderfloorHeatingAccessories13

Underfloor Heating

3-16

BLC PewHeaters41BLS 110V Convector Heaters 42SWD IndustrialTubularHeaters44

Convection Heaters

41-45

Und

erflo

or H

eatin

g an

d

Free

ze P

rote

ction

Pro

duct

sCo

mm

erci

al a

nd In

dust

rial

Heat

ers a

nd C

ontr

ols

Page 3: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432

Underfloor Heating and

Freeze Protection Products

Underfloor Heating and Freeze Protection Products

Page 4: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 5314324

UNDE

RFLO

OR H

EATI

NGM Series Heating Mats• An economic method of heating a room and providing a

luxurious warm floor• Manufactured to highest quality for complete peace of

mind and backed by a 10 year warranty

Application• Suitableforanyroomincludingconservatories,bathrooms

andwetrooms• Idealforusewithawidevarietyoffloorsurfacesincluding

ceramictiles,porcelaintiles,marble,slate,stone,carpet,vinyl,engineeredwoodandlaminateflooring.

Features• Twincoreheatingcablepre-assembledontoanylonweb

ensuringuniformspacingandeaseofinstallation• Pre-wired3mpowerlead• Continuousearthfoil• Continuousdoublesidedtapeofundersideofheatingmat

allowssecureplacingonanycleansurface

Cable Specification• ApprovedtoEN60335-2-96asrequiredbythe17thEditionWiringRegulations(BS7671.2008)• EMCcompliant• 230Vsupply• Twincorecablediameter3mmto4mm• EarthscreenprotectionbymeansofAL/PETFoil

Installation

Tiled FloorTheMSeriesheatingmatshouldbeinstalledinaflexibleself-levelingcompoundordirectlyintothetileadhesive.Itisimportantthattheheatingcableiscompletelycovered.

Other Floor Surfaces (carpet, vinyl, engineered wood and laminate floor)TheMSeriesmatshouldbecompletelycoveredinaflexibleself-levelingcompoundwiththerequiredfloorsurfaceappliedoncethecompoundiscompletelydry.Greatcaremustbetakentoensurethatfixingdevicesarenotdriventhroughtheheatingcable.Whereunderlayisrequired,thelowesttogoptionisrecommended.Ifthereisanydoubtaboutthesuitabilityofanygivenfloorsurfaceforusewithunderfloorheating,confirmationshouldbesoughtfromtheflooringsupplier.

Selection

Standard or High DensityOtherthaninexceptionalcircumstancesstandarddensityheatingmatswillprovideenoughoutputtoserveasasolesourceofheatinaroom.Highdensitymatsmaybepreferredwhenoneofthefollowingapplies.• Aroomhasexceptionallyhighheatlosses(thismayapplytosomeconservatories)• Averyrapidheatupisrequiredperhapsbecausearoomisrarelyused• Itisonlypossibletoheatasmallpercentageofthetotalfloorarea

10

Typical M Series Installation

Electrical connection + thermostat

Mat cut here

Mat cut here

Mat cut here

Cold lead

KitchenLarder

Page 5: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 5

UNDERFLOOR HEATINGSize of MatTheobjectiveisgenerallytocoverashighapercentageofthefreefloorareaaspossible.Thefreefloorareaisdefinedasthefloorareanotoccupiedbypermanentfixturessuchaskitchencabinetsandshowertrays.Asaruleofthumb,wesuggestselectingamatwithtotalareaapproximately10%lessthanthetotalfreefloorarea.Thiswillallowforperimeterspacingandensureeasyinstallation

Large RoomsForlargeroomsitiscommonpracticetousemorethanoneheatingmat.Inthesecircumstancesthereisachoiceofsubdividingtheroomintoseparatezoneseachcontrolledbyitsownthermostatorconnectingtheheatingmatstogetherelectricallyinparallelandusingasinglethermostat.Whencontrollingmorethanoneheatingmatfromasinglethermostatitmaybenecessarytoincorporateacontactorintothecontrolcircuit.Alternatively,BNThermic'sWirelessControlSystemallowsseveralheatingmatstobecontrolledwithoutacontactor(seepage14)

M Series Standard Density Mats (150W/m²) - SpecificationsModel Heated Area (m²) Mat Size (m) kW Weight (kg)M150-005 0.5 1.0x0.5 0.07 0.7M150-010 1.0 2.0x0.5 0.15 1.4M150-015 1.5 3.0x0.5 0.22 2.1M150-020 2.0 4.0x0.5 0.30 2.8M150-025 2.5 5.0x0.5 0.37 3.5M150-030 3.0 6.0x0.5 0.45 4.2M150-035 3.5 7.0x0.5 0.52 4.9M150-040 4.0 8.0x0.5 0.60 5.6M150-050 5.0 10x0.5 0.75 7.0M150-060 6.0 12x0.5 0.90 8.4M150-070 7.0 14x0.5 1.05 9.8M150-080 8.0 16x0.5 1.20 11.2M150-090 9.0 18x0.5 1.35 12.6M150-100 10 20x0.5 1.50 14.0M150-110 11 22x0.5 1.65 15.4M150-120 12 24x0.5 1.80 16.8

High Density Mats (200W/m²) - SpecificationsRecommendedforConservatories

Model Heated Area (m²) Mat Size (m) kW Weight (kg)M200-010 1.0 2.0x0.5 0.20 1.4M200-020 2.0 4.0x0.5 0.40 2.8M200-030 3.0 6.0x0.5 0.60 4.2M200-040 4.0 8.0x0.5 0.80 5.6M200-050 5.0 10x0.5 1.00 7.0M200-060 6.0 12x0.5 1.20 8.4M200-070 7.0 14x0.5 1.40 9.8M200-080 8.0 16x0.5 1.60 11.2M200-090 9.0 18x0.5 1.80 12.6M200-100 10 20x0.5 2.00 14.0

FOR THERMOSTATS, INSULATION AND OTHER ACCESSORIES - See PAGES 13-16

Page 6: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel +44 (0)1293 547361 fax +44 (0)1293 5314326

UNDE

RFLO

OR H

EATI

NGEHC Heating Cables• An economic method of heating a room and providing a

luxurious warm floor• Manufactured to highest quality for complete peace of

mind and backed by a 10 year warranty• Ideally suited to small and irregularly shaped rooms

Application• Suitableforanyroomincludingconservatories,

bathroomsandwetrooms• Idealforusewithawidevarietyoffloorsurfaces

includingceramictiles,porcelaintiles,marble,slate,stone,carpet,vinyl,engineeredwoodandlaminateflooring.

Features• Twincoreheatingcablesuppliedwithhighadhesiontape• Pre-wired3mpowerlead• Continuousearthfoil

Cable Specification• ApprovedtoEN60335-2-96asrequiredbythe17thEditionWiringRegulations(BS7671.2008)• EMCcompliant• 230Vsupply• Twincorecablediameter3mmto4mm• EarthscreenprotectionbymeansofAL/PETFoil

Installation

Tiled FloorTheEHCheatingcableshouldbeinstalledinaflexibleself-levelingcompoundordirectlyintothetileadhesive.Itisimportantthattheheatingcableiscompletelycovered.

Other Floor Surfaces (carpet, vinyl, engineered wood and laminate floor)TheEHCheatingcableshouldbecompletelycoveredinaflexibleself-levelingcompoundwiththerequiredfloorsurfaceappliedoncethecompoundiscompletelydry.Greatcaremustbetakentoensurethatfixingdevicesarenotdriventhroughtheheatingcable.

Typical EHC Installation

10

EHC Heating cable

Tiles

Tile adhesive

Fixing tape

SubfloorF-Board Insulation

(optional)

Page 7: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 7

UNDERFLOOR HEATINGWhereunderlayisrequired,thelowesttogoptionisrecommended.Ifthereisanydoubtaboutthesuitabilityofanygivenfloorsurfaceforusewithunderfloorheating,confirmationshouldbesoughtfromtheflooringsupplier.

SelectionTheobjectiveisgenerallytocoverashighapercentageofthefreefloorareaaspossible.Thefreefloorareaisdefinedasthefloorareanotoccupiedbypermanentfixturessuchaskitchencabinetsandshowertrays.Usethetableprovidedtoselectthecorrectcable.

Large RoomsForlargeroomsitiscommonpracticetousemorethanoneheatingcable.Inthesecircumstancesthereisachoiceofsubdividingtheroomintoseparatezoneseachcontrolledbyitsownthermostatorconnectingtheheatingcablestogetherelectricallyinparallelandusingasinglethermostat.Whencontrollingmorethanoneheatingcablefromasinglethermostatitmaybenecessarytoincorporateacontactorintothecontrolcircuit.Alternatively,BNThermic'sWirelessControlSystemallowsseveralheatingcablestobecontrolledwithoutacontactor(seepage14)

EHC Heating Cables - SpecificationsModel Volts kW Heated Area (m²) Cable Length (m) Weight (kg)EHC-012 230 0.12 0.7–1.0 11 1.1EHC-020 230 0.20 1.1–1.5 19 1.2EHC-025 230 0.25 1.6–2.0 24 1.4EHC-032 230 0.32 2.1–2.5 32 1.6EHC-040 230 0.40 2.6–2.9 37 1.7EHC-045 230 0.45 3.0–3.3 46 2.0EHC-052 230 0.52 3.4–3.8 50 2.4EHC-060 230 0.60 3.9–4.5 64 2.7EHC-075 230 0.75 4.6–6.0 76 2.9EHC-095 230 0.95 6.1–7.5 87 3.2EHC-110 230 1.10 7.6–8.5 115 4.0EHC-130 230 1.30 8.6–10.0 131 4.8EHC-170 230 1.70 10.1–13.0 159 6.3EHC-200 230 2.00 13.1–15.5 194 8.4

Electrical connections+ thermostat

Cold lead

FOR THERMOSTATS, INSULATION AND OTHER ACCESSORIES - See PAGES 13-16

An EHC heating cable installed in a bathroom

Page 8: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 5314328

UNDE

RFLO

OR H

EATI

NGF Series Foil Heating Mats for laminate and engineered wood floors• Providingeconomicheatingandluxuriouswarmfloorsinanyroomincludingbathrooms• Easytoinstallwithoutrequiringadhesiveorcompounds• Manufactured to the highestqualityforcompletepeaceofmindandbackedbya10yearwarranty

Applications• Suitableforanyroomincludingbathrooms

• Specificallydesignedforusewithlaminateorengineeredwoodfloors

Features• AnFSeriesFoilHeatingMatcanbemanipulatedtofillaspaceinthesamewayasaconventionalunderfloorheatingmat

• Lowprofiledesign(approximately2mmthick)keepstheincreaseinfloorheighttoaminimum• Theheatingcablearesandwichedbetweentwolayersofaluminiumfoilforexcellentheatdistribution

• Pre-wired3mpowerlead

Specification• ApprovedtoEN60335-1:2012,EN60335-2-96:2003,EN55014-1:2006,EN55014-2:1997

• HeatingCable:CuNi,CuZnalloywithETFEdoubleinsulation• 230VSupply

InstallationFSeriesFoilHeatingMatsareinstalleddirectlybelowthefinalfloorsurface(laminateorengineeredwood).Thematshouldbeinstalledontopofalayerofextrudedpolystyrenesheetwhichwillactasanunderlay.Thislayerwillalsoimprovethefloorinsulationlevels,limitingdownwardheatlossandimprovingeconomy.BNThermic’sDEP-6isidealforthisapplication(seepage16).

SelectionTheobjectiveisgenerallytocoverashighapercentageofthefreefloorareaaspossible.Thefreefloorareaisdefinedasthefloorareanotoccupiedbypermanentfixturessuchaskitchencabinetsandshowertrays.Asaruleofthumb,wesuggestselectingamatwithanareaapproximately10%lessthanthefreefloorarea.ThiswillallowforperimeterspacingandensureeasyinstallationForlargeroomsitiscommonpracticetousemorethanonefoilmat.Inthesecircumstancesthematsareusuallyconnectedinparallelandcontrolledbyasinglethermostat.Whenthecombinedloadexceedstheswitchingcapacityofthethermostat,therewillbenecessarytoincorporateacontactorintothecontrolcircuit.Alternatively, BNThermic'sWirelessControlSystemallowsseveralheatingmatstobecontrolledwithoutacontactor(seepage14)

10

F Series foil heating mat specifically designed for laminate and engineered

wood floors

Page 9: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 9

UNDERFLOOR HEATINGF Series Foil Heating Mats – SpecificationsModel kW Heated Area (m²) Mat Size (m)F140-010 0.14 1.0 2.0x0.5F140-015 0.21 1.5 3.0x0.5F140-020 0.28 2.0 4.0x0.5F140-040 0.56 4.0 8.0x0.5F140-060 0.84 6.0 12x0.5F140-080 1.12 8.0 16x0.5F140-100 1.40 10 20x0.5

FOR THERMOSTATS, INSULATION AND OTHER ACCESSORIES - See PAGES 13-16

A low profile F Series Installation

Subfloor

DEP6 Insulation/underlay

F Series Foil Heating Mat

Laminate or engineered wood flooring

Externally mounted thermostat

Cold Lead

Cut mat here

Cut mat here

Cut mat here

Cut mat here

Cut mat here

BATH

SHOWER TRAY

Typical F Series Installationin a bathroom

Page 10: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143210

UNDE

RFLO

OR H

EATI

NGLH Heating films for laminate and engineered wood floors• Providing an economic method of heating a room and providing a

luxurious warm floor• Easily and quickly installed under laminate and engineered wood

floors without the need for adhesives or compounds• Manufactured to highest quality for complete peace of mind and

backed by a 10 year warranty

Application• Suitableforanyroomexceptbathroomsandwetrooms• Specificallydesignedforusewithlaminateorengineeredwoodfloors

Features• Lowprofilesystem,combinedthicknessofinsulation/underlay,heating

andvapourbarrierisapproximately7mm• Twowidthsofheatingfilmandawiderangeoflengthsforgoodfloor

coverageinanysizeofroom• Pre-wired4mpowerleads• LHheatingfilmscanbeeasilyreducedinlengthduringtheinstallationprocess

Film Specification• ApprovedtoEN60335-2-96asrequiredbythe17thEditionWiringRegulations(BS7671.2008)• EMCcompliant• 230Vsupply• Polyesterfilmlessthan1mmthick

InstallationThreelayersarerequired:

1st Layer DEP6 Insulation/UnderlayTheentirefloorareamustbecoveredbya6mmthicklayerofDEP6. Thislayerperformsfourfunctions.• Thermalinsulationlimitingdownwardheatloss• Amoistureproofbarrierbetweentheheating

filmandthesub-floor• Sound deadening• Anon-abrasivesurfaceontowhichtheheating

filmcanbeinstalled

2nd Layer LH FilmAnumberofLHheatingfilmsareinstalledsidebysidetofillthefloorareaTheheatingfilmsareelectricallyconnectedinparallelandcontrolledbyasinglethermostat

3rd Layer VB Vapour Barrier TheentirefloormustbecoveredinalayerofVBvapourbarrier.Thislayerperformsthreefunctions• Secondaryelectricalinsulation• Protectionfrommajorliquidspills• AmechanicalbarrierbetweentheheatingfilmandthefloorsurfacepreventingabrasionDEP6,LHFilmandVBshouldallbesecuredusingLHTHighAdhesiveTape.One50mrollisrequiredforeach10m²offloorarea.

10LH Heating Films

Easy to install under laminate or engineered wood without adhesive

Laminate floor

VB Vapourbarrier

LH Film

DEP6Insulation/underlay

Subfloor

The components of an LH heating system: no adhesives or compounds are required

Page 11: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 11

UNDERFLOOR HEATINGSelectionStep One Drawaplanoftheroomidentifyingareasoccupied

bypermanentfixturessuchaskitchencabinetsStep Two Drawtheheatingfilmssidebysideontotheplan

keepingallelectricalconnectionsalongonewallwhereverpossible.Foreaseofinstallationwesuggestusingasmallnumberofwiderfilmsratherthanalargernumberofnarrowerfilms.Frequentlyacombinationofwiderandnarrowerfilmswillberequired.Shouldyouselectafilmslightlytoolongfortheroom,itisasimpleprocesstoreducethelengthofthefilmduringinstallation.

Step Three SelectthecorrectnumberofDEP6insulation/underlayboardsandVBvapourbarrierstocovertheentirefloorarea.BothDEP6andVBmustbeusedintheinstallation.AllowonerollofLHTtapeforevery10m²offloorarea

LH Heating for Laminate & Engineered Wood Floors - SpecificationsModel Volts kW Dimensions (m)

W LLH4-010 230 0.04 0.4 1.0LH4-015 230 0.06 0.4 1.5LH4-020 230 0.09 0.4 2.0LH4-025 230 0.11 0.4 2.5LH4-030 230 0.13 0.4 3.0LH4-035 230 0.15 0.4 3.5LH4-040 230 0.17 0.4 4.0LH4-045 230 0.19 0.4 4.5LH4-050 230 0.21 0.4 5.0LH4-060 230 0.26 0.4 6.0LH4-070 230 0.30 0.4 7.0LH4-080 230 0.34 0.4 8.0LH4-090 230 0.39 0.4 9.0LH4-100 230 0.43 0.4 10LH10-010 230 0.13 1.03 1.0LH10-015 230 0.19 1.03 1.5LH10-020 230 0.26 1.03 2.0LH10-025 230 0.32 1.03 2.5LH10-030 230 0.39 1.03 3.0LH10-035 230 0.45 1.03 3.5LH10-040 230 0.52 1.03 4.0LH10-045 230 0.58 1.03 4.5LH10-050 230 0.65 1.03 5.0LH10-060 230 0.78 1.03 6.0LH10-070 230 0.91 1.03 7.0LH10-080 230 1.04 1.03 8.0LH10-090 230 1.17 1.03 9.0LH10-100 230 1.30 1.03 10

Live + NeutralCables

Typical LH Installation

Electrical connections+ thermostat

Coldlead

Built-in

Wardrobe

FOR THERMOSTATS, INSULATION AND OTHER ACCESSORIES - See PAGES 13-16

Page 12: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143212

UNDE

RFLO

OR H

EATI

NGLH-K Heating film kits for laminate and engineered wood floor

FOR THERMOSTATS, INSULATION AND OTHER ACCESSORIES - See PAGES 13-16

• AnalternativetoourLHpre-terminatedfilms• Allowstheprofessionalinstallertotailoraheatingsystempreciselytoaspecificspace• Provides130W/m²poweroutput• ManufacturedtohighestqualityforcompletepeaceofmindandbackedbyatenyearwarrantySeeLHpage10forapplications,specificationandfloorbuild-up.

Features AsLHexcept• 500mmwidefilmcanbecutandterminatedatanypoint• Kitincludessufficientcomponents(including

crimpsandcables)formoststandardshapedrooms.

Kit Contents• Rollof500mmwide130W/m²

heatingfilm• 15minsulatedcoldlead(brown)• 15minsulatedcoldlead(blue)• 20connectioncrimps• 20insulatingdiscs• 1mmastictape• Crimpingtool• Installationinstructions.

The following items must be ordered separately (see ACCS)• DEP6insulation/underlay–sufficienttocovertheentirefloorarea• VBvapourbarrier–sufficienttocovertheentirefloorarea• LHTfixingtape–onerollofLHTtapeforevery10m²offloorarea• Thermostat.

LH-K Kit - SpecificationsModel Square Area CoveredLH-K05 Upto5m²LH-K10 5to10m²LH-K15 10to15m²LH-K20 15to20m²

LHK- Kit ‘top ups’Model DescriptionLHTU-05 Rolloffilm5m²LHTU-10 Rolloffilm10m²LHTU-15 Rolloffilm15m²LHTU-20 Rolloffilm20m²LHTU-BR 15mcoldleadbrownLHTU-BL 15mcoldleadblueLHTU-CR 20CrimpsLHTU-MA 1mmastictapeLHTU-ID 20insulatingdiscsLHTU-CT CrimpingTool

LH-K 'Top Ups'

Roll of film

Cold Leads

Pack of 20 crimps

Mastic tape

Pack of 20 insulating discs

Crimp tool

Page 13: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 13

UNDERFLOOR HEATING ACCESSORIESACCS Underfloor Heating AccessoriesStandard Control

ThermostatsThermostaticcontrolmustbeusedwithallBNThermicUnderfloorHeatingSystems.BNThermicoffersarangeofthermostatsallofwhicharesuppliedwithafloorprobe.Thethermostatscanbeconfiguredforprimarycontrolviathebuilt-inairsensororviathefloorsensor.Forlargerinstallations,checkthatthetotalloadiswithintheswitchingcapacityoftheselectedthermostat.Whenthecombinedloadisgreaterthantheswitchingcapacityoftheselectedthermostatanappropriatelyratedcontactormustbeselected.Alternatively,BNThermic'sWirelessControlSystemallowslargerloadstobecontrolledwithoutacontactor(seepage14).

A16CSimplicityisthekey.TheA16Chasasmartunclutteredappearancewithadialfortemperatureadjustmentandanon/offswitch.Capableofswitchingloadsupto3.4kW,theA16Cisconfigurablefor‘airandfloorsensor’or‘floorsensoronly’.

U16CTheU16Cofferssimple7-dayprogrammingwithprogrammingbuttonshiddenbehindhingeddoorsonthethermostatface.Capableofswitchingloadsupto3.4kW,theU16Cisconfigurablefor‘airandfloorsensor’or‘floorsensoronly’.Featuresincludeabacklitscreenandasummerswitchallowingtheheatingtobeswitchedoffwithoutlosingtheprogramme.

T16COurlatestfullcolourtouchscreenthermostatscanswitchloadsofupto3.6kWandprovideultra-simple7-dayprogramming.Availablewithachoiceofwhite,silverorblacksurrounds,theT16Ccanbeconfiguredfor‘airandfloor’or‘flooronly’control.Whenrequired,theairtemperaturecanbecontrolledviaanIP65ratedremotemountedwall-sensor(T16R).Thisarrangementisparticularlywellsuitedforbathroomapplications.TheT16Calsoallowstheusertomonitorenergyusageandrunningcosts.

U16C Fully programmable

control

A16C Simple stylish

control

T16ROptional remote wall sensor for use with T16C

thermostat

Floor probe and conduit provided

with every BN Thermic thermostat

T16CW T16CS

Stylish ‘ state of the art’ touch screen control

T16CB

ThermostatsModel Load Operation SensorA16C 15A ManualThermostat AirandfloororflooronlyU16C 15A ProgrammableThermostat AirandfloororflooronlyT16CW 16A ProgrammableTouchScreen(White) AirandfloororflooronlyT16CS 16A ProgrammableTouchScreen(Silver) AirandfloororflooronlyT16CB 16A ProgrammableTouchScreen(Black) AirandfloororflooronlyT16R OptionalIP65remotesensorforusewiththeT16Ctouchscreenthermostat

Page 14: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143214

UNDE

RFLO

OR H

EATI

NG A

CCES

SORI

ESACCS Continued

Wireless ControlDifferentcombinationsofthreestandardcomponentsprovideanumberofconvenient,wirelesscontrolsystemsforunderfloorheating.

WSB-1 Relay BoxGenerallymountedatlowlevel,theWSB-1RelayBoxwillswitchanunderfloorheatingloadofupto16A(3.6kW).Eachrelayboxissuppliedwithafloorprobeformonitoringfloortemperature.TheWSB-1willcontroltheheatingaccordingtowirelesssignalsreceivedfromaWST-1thermostatand/oraWSP-1centralprogrammer.TheWSB-1canbeinstalledinanyroom,includingbathrooms.

WST-1 Wireless ThermostatTheWST-1thermostatisbatterypoweredandcanbewall-mountedorsimplyplacedinaconvenientlocationusingthesmallstandprovided.AnWST-1cansendawirelesssignaltoone,two,threeorfourrelayboxes.ThecombinationofanWST-1thermostatandtherequirednumberofWSB-1relayboxesallowslargerroomstobecontrolledbyonethermostatwithouttherequirementtoinstallacontactor.IfusedwiththeWSP-1centralprogrammer,theWST-1’sprogrammablefunctionsaresupersededanditactsprimarilyasawirelessairtemperaturesensorwithatemporaryoverridefunction.

WSP-1 Central ProgrammerTheWSP-1isacompact,touchscreendeviceprovidingwirelesscontrolforupto24zonesofheating.GenerallyspeakingaheatingzonewouldbeanindividualroommeaningthattheWSP-1canbeinstalledinthelargestofproperties.ThecombinationofasingleWSP-1centralprogrammerandtheappropriatenumberofWST-1thermostatsandWSB-1relayboxes,allowscompletelyflexiblecontrolofeveryroomonahousefromacentrallocation.

Wireless ControlModel Description

WSB-1 WirelessRelayBox16AWST-1 WirelessThermostat(forusewithWSB-1relaybox)WSP-1 WirelessCentralProgrammer

Contactor and Enclosure

ContactorsAsuitableratedcontactorallowsathermostattocontrolaloadlargerthanitsnormalswitchingcapacity.

ContactorsModel Amperage Max kW Enclosure TypeCON-20 20 4.4 ACON-40 40 7.8 BCON-63 63 12 BENCL-A ContactorEnclosureTypeAENCL-B ContactorEnclosureTypeB

WSB-1 Relay Box

WST-1 Wireless Thermostat

WSP-1 Central Programmer

Page 15: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 15

UNDERFLOOR HEATING ACCESSORIES

Insulation for EHM mats and EHC cables

F-BoardTolimitdownwardheatlossandtosignificantlyimprovetheeconomyofanunderfloorheatingsystem,theuseofF-Boardinsulatedtilebackerboardsishighlyrecommended.Installeddirectlyontothesub-floorandbelowtheheatingmatorcable,theyprovideexceptionalthermalinsulationwithminimalincreaseinfloorheight.F-Boardinsulatedtilebackerboardsaregenerallyheldinplaceusingstandardtileadhesive.

SelectionEachF-Boardcovers0.72m²andsufficientboardsshouldbeselectedtocompletelycoverthefloorarea.Totalfloorarea(m²)÷0.72=minimumnumberofboardsrequired

F-Board-6 Providesanextremelyeffectiveinsulationbarrierwherefloorbuild-upmustbekepttoaminimum.

F-Board-10Astheeffectivenessofinsulationincreaseswiththickness,F-Board-10shouldbeselectedwheremaximumeconomyisrequiredandadditionalfloorbuild-upisacceptable.

Features• Fullresistancetomoistureabsorption• Combinationoflowprofile,strengthandthermalefficiency• Lightweightandeasilycuttoshape• Easilyfixedinplaceusingstandardtileadhesive

Insulation for EHM and EHCModel Description Dimensions (mm) Area Covered (m²)F-Board-6 Insulation 1200x600x6 0.72F-Board-10 Insulation 1200x600x10 0.72

F-Board-6 and -10Significantly improving economy by

restricting downward heat loss

WSP-1Central

Programmer

WSB-1Relay Box

WSB-1Relay Box

WSB-1Relay Box

WST-1Wireless

Thermostat

WST-1Wireless

Thermostat

A Typical Wireless Control System

LARGE ROOM Requiring 2x WSB-1 Relay Boxes

SMALLER ROOM Requiring 1x WSB-1 Relay Box

Page 16: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143216

UNDE

RFLO

OR H

EATI

NG A

CCES

SORI

ESACCS Continued

Floorprep Primer & Roller Prepares a sub-floor for EHM Heating Mat and

EHC Heating Cable

installation

EHM-R Emergency Repair Kit Rarely needed but always

immediately available

Miscellaneous

Floorprep PrimerSuppressesdustandimprovesadhesiononavarietyofsub-floortypesincludingconcreteandplywood.OnebottleofFloorprepPrimercoversapproximately6m²whendiluted1:1.FloorprepiseasilyappliedusingaFloorrollRoller.FloorprepisnotrequiredwhenusingF-Boardinsulatedtilebackerboard

EHM-R-Kit - Cable Repair Kit For emergency use onlyThisrepairkitcanbeusedtorepairaheatingcablethathasbeendamagedduringinstallationorbydrillingthroughthefloor.ItissuitableforbothEHMHeatingMatsandEHCHeatingCable.

Insulation for EHM and EHCModel DescriptionFloorprep Primer500ml(covers6m²approx-diluted1:1)Floorroll RollerforapplyingPrimerEHM-R-Kit CableRepairKit(foremergencyuseonly)

Insulation and vapour barrier for LH films, LH-K film kits and F Series foil heating matsLHfilmsandLH-KfilmkitsmustbeinstalledontoalayerofDEP6 insulation/underlay and under VB vapour barrier. BothDEP6insulation/underlayandVBvapourbarriermustcovertheentirefloorarea(notjusttheheatedsection).BothDEP6andVBmustbeheldinplacebyLHTmoistureresistantfixingtape.DEP6istheidealinsulation/underlayforFSeriesfoilheatingmats(VBvapourbarrierisnotrequired).AllowoneVBvapourbarrierandoneLHTmoistureresistanttapeforevery10m²offloorarea

Accessories for LH, LH-K and F SeriesModel Description Dimensions (mm) Area Covered (m²)DEP-6 Insulation 1250x800x6 1.0VB VapourBarrier 4000x3000 12LHT 50mHighAdhesiveTape(onerollfor10m²floorarea)

VB Vapour barrier Combined thickness of

LH installation is approximately 7mm

DEP6 only 6mm thick providing insulation and

underlay

LHT High Adhesive Tape

Page 17: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 17

MIRROR DEM

ISTERS

Peel-off adhesive backing

MD Mirror Demister Pads

Selection

MD MIrror Demister Pads - SpecificationsModel Volts Watts Dimensions (mm)MD-12 230 12 252x274MD-28 230 28 574x274MD-50 230 50 519x524MD-100 230 100 1004x524

MD-50 50W Demister pad with a

typical running cost of 5 pence per week

• Providing a mist free mirror

• 100% effective in little over 2 minutes

• Very low energy consumption

• Simply integrated into the lighting circuit ensuring that

they are not left running

Features• Protectsanareaapproximately20%largerthanthepad

itself

• Doubleinsulatedandcompletelysealedfortotalsafety

• Lessthan1mmthick

• Peeloffadhesivebacking

• 1mlongpowerlead

Page 18: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143218

PIPE

FRE

EZE

& G

UTTE

R PR

OTEC

TION

GP Self-regulating Cable for Gutters and Downpipes• Stops accumulation of ice in gutters and downpipes • Prevents damage to gutters and downpipes• Ensures that rain and melt-water can drain away

normally and not cause damage to properties• Reduces danger to people from collapsing gutters and

falling icicles.

Typical ApplicationsTheGPsystemisidealforbothdomesticandcommercialinstallation.

Features• Energysavingself-regulatingcable–outputreducesas

ambienttemperaturerises• Self-regulatingtechnologyeliminates‘hotspots’and

failurescausedbycablestouchingorcrossing• Parallelcabletechnologyallowscabletobecuttolengthonsitewithoutaffectingwattspermetreoutput• Thecable’sPolyolefinsheathisUVresistantensuringlongoperatinglifeinexposedareas• ‘Gel’filledpowerconnectorandendsealallowquickinstallationwithouttheneedforaheatgunorcrimptool.

Thehigh-techinsulatinggelallowssafeandsecurejointsandterminationstobemadeinafewminutes.

Controlling GP Self-Regulating CableChoosebetweenmanualandthermostaticcontrol.Manualcontrolbymeansofasimpleswitchiscommonlyadoptedforsmalldomesticinstallations.ForlargerinstallationswerecommendcontrolbymeansofaGP-Telectronicthermostat.Theproblemsassociatedwithsnowandiceoccurwhentheambienttemperatureisbetween+5⁰Cand-5⁰C.Toensuremaximumeconomy,theGP-Thastwoset-points.Inthiswaythesystemwillbeswitchedoffwhenthetemperatureiseithertoohighortoolowforproblemstoarise.TheGP-Tshouldbemountedexternallyinashelteredlocation.ThethermostatconformstoIP65.Seepage66forfulldetails.

Selection

GuttersForguttersupto120mmwideuseasinglerunofGP-18cable.Forwiderguttersuseanadditionalrunofcableforeveryadditional120mmincreaseinwidth.

GP-T with cover removed showing set-point adjustment knobs

GP-T with cover in place

Keep gutters and downpipes ice-free

Single run of GP-18 cable in a typical domestic gutter

GP-18 cable installed in a wide gutter with spacing

maintained by GP-S spacerDownpipesFordownpipesattheendofagutter,asinglerunofGP-18willberequiredwithcableextendingapproximately500mmbelowgroundlevel.Thegelfilledendsealwillbeappliedtotheendoftherun.Fordownpipeswhichinterruptagutter,adoubleloopofcableshouldbeinstalledwiththeendoftheloopextendingapproximately500mmbelowgroundlevel.Strainreliefwillberequiredfordownpipeslongerthan34m

GC-E gel filled end seal

GP-18 protecting gutter and downpipe with downpipe at the end of the run

GP-18 protecting gutter and downpipe with a centrally located downpipe

GC-E gel filled end

seal

GC-P gel filled

connector in sheltered

location

GC-P gel filled

connector in sheltered

location

Page 19: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 19

PIPE FREEZE & GUTTER PROTECTION

TerminationsBNThermic’sgelfilledterminationdevicesshouldbeused.Eachcablerunwillrequire1xGC-Pconnectorand1xGC-Eendseal.TheGC-Pshouldbemountedinashelteredlocationandisusedtoconnecttheheatingcabletothepowerlead(a2.5mm²twinandearthcableisrecommended).TheGC-Eisusedtosealtheendofacablerun.

Spacer KitsEachGP-Sspacerkitconsistsof5stainlesssteelspacersand10UVresistantcableties.Thespacersareusedtoprotectthecableasitpassesoverasharpedgeandtomaintainthecorrectspacingwhenmultiplecablerunsareinstalledinagutter.

GP-18 Cable SpecificationVoltage 230VNominalOutputat0⁰CInicewater 36W/mInair 18W/mMinimuminstallationtemperature -40⁰CMaximumexposuretemperatureWithpoweron 65⁰CWithpoweroff 85⁰CMinimumbendingradius 25mmMaximumcircuitlength 65m

Roof ProtectionInareassubjecttosevereclimaticconditionsitmaybenecessarytoprotecttheloweredgeofapitchedroof.GP-18cableisidealforthisapplication.PleasecalltheBNThermicsalesofficetodiscuss.

PleasenotethatGP-18isnotsuitableforusewithbitumenortarrelatedsurfacessuchasroofingfelt.

GP Gutter Protection Cable - SpecificationsModel DescriptionGP-18 Self-regulatingcable–bythemetreGC-P GelfilledconnectorGC-E GelfilledendsealGP-S Spacer KitGP-T ThermostatIP65

GC-P gel filled connector providing quick means of connecting power lead

GC-E gel filled push fit end seal

GP-S spacer kit GP-S spacer protecting GP-18 cable from a sharp edge

Tin coated copper bus wires

Self limiting polymer with bonded jacket

Thermoplastic insulation

Thermoplastic overjacket

Tin-coated copper braid

Structure of GP-18 heating cable

A length of GP-18 cable supplied on a drum for easy handling

Page 20: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143220

PIPE

FRE

EZE

& G

UTTE

R PR

OTEC

TION

ERC Snow and Ice Melting Heating Mats• Preventstheaccumulationofsnowandiceinoutdoorlocations• Ensuresyear-roundaccesstodomesticand

commercialpremises• Ensurethesafetyof

staffandpublicinicyconditions

Typical Applications• Driveways• Ramps• Disabledaccess• Patios• Parkingareas• Concreteandpavingslabsurfaces

Features• Singlecoreheatingcablepre-assembledontoawebmatensuring

uniformspacingandeaseofinstallation• Pre-wiredasymmetricalcoldleads:5matoneendand5mplusthelengthofthematattheotherend• Continuoussafetyearthbraidthroughouttheentirecable• 300W/m²powerdensity

Cable ConstructionCore: StrandedresistancewirePrimary insulation: 0.15mmfluoropolymer(FEP)Secondary insulation: 0.8mmcross-linkedpolythene (XLPE)Earth braid: 14x0.3mmdia.tinnedcopper wiresandAIPETfoilOver-jacket: 1mmPVC(105⁰C)

Selection and InstallationDecideontheareatobeheated(inm2)thensimplyselectamatoracombinationofmatstocoverthisarea.ThecablesupportingmatcanbecutatanypointtosuittheshapeoftheareabuttheheatingcableitselfmustNEVERbecut.ERCmatscanbeinstalledinconcreteorinfinewashedsandunderpavingslabs.Wheninstallinginconcrete,caremustbetakennottocrossexpansionjoints.

ControlERCHeatingMatsshouldbecontrolledbyanERC-T1energysavingthermostatwhichwillreduceenergyconsumptionbyapproximately80%whencomparedwithasimpleairthermostat.TheERC-T1isinstalledinsidethebuildingandcomescompletewithasensorforoutdoorinstallation.Thissensorisinstalledatgroundlevelandmonitorsbothtemperatureandmoistureensuringthatthesystemwillonlybeenergisedwhentheconditionsarelikelytoleadtoiceorsnowaccumulation(seepage67forfulldetails).TheERC-T1willswitchloadsupto16Adirectly.Forlargerloadsasuitablyratedcontactorwillberequired(seepage64).

ERC Snow and Ice Melting Mat. An economic

means of preventing the accumulation of snow

and ice.

ERC Snow and Ice Melting Mat providing safe access to an office building

ERC-T1 Providing economic control of ERC Snow and Ice Melting Mats

Page 21: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 21

PIPE FREEZE & GUTTER PROTECTION

ERC Snow and Ice Melting Heating Mat - 300W/m² Mat - SpecificationsModel Volts kW Heated Area (m²) Mat Size (m) Weight (kg)ERC-045 230 0.45 1.5 3x0.5 1.5ERC-060 230 0.6 2.0 4x0.5 1.9ERC-090 230 0.9 3.0 6x0.5 2.6ERC-120 230 1.2 4.0 8x0.5 2.8ERC-150 230 1.5 5.0 10x0.5 3.6ERC-180 230 1.8 6.0 12x0.5 4.5ERC-210 230 2.1 7.0 14x0.5 5.3ERC-240 230 2.4 8.0 16x0.5 5.2ERC-270 230 2.7 9.0 18x0.5 6ERC-300 230 3.0 10 20x0.5 6.7ERC-360 230 3.6 12 24x0.5 8.6ERC-450 230 4.5 15 30x0.5 9.7ERC-600 230 6.0 20 40x0.5 14.8

ControlsModel DescriptionERC-T1 Snow&IceMeltingController&Sensor

ERC Snow and Ice Melting Mat prepared for concrete

pour

Page 22: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143222

PIPE

FRE

EZE

& G

UTTE

R PR

OTEC

TION

CRJ Self Regulating Water Pipe Freeze Protection Cable• Prevents water from freezing in metal and plastic pipes• Avoids the cost and inconvenience of burst pipes• Self regulating technology and recommended thermostatic control ensures

lowest possible running costs

Typical Applications• Stables• Sprinklersystems

Features• Selfregulatingtechnologyensuresthatcableoutputwilldecreaseasambient

temperatureincreases• Canbecuttolength,terminated,TjointedandsplicedonsiteusingtheBN

Thermic’sterminationandsplicekits• Canbedoublewrappedtoprotectvalves,flangesetc.withoutriskofcreating

hot spots• Fullymoistureproofwithfulllengthearthbraid

Controlling CRJ Self Regulating Pipe Freeze Protection cableAlthoughthecable’sselfregulatingtechnologyensuresthatcableoutputwilldecreaseasambienttemperatureincreases,thermostaticcontrolisstillrecommended.Amasterfrostthermostatwillpreventthelowlevelofelectricityconsumptionthatwouldotherwiseoccurwhentheambienttemperatureisabovefreezingpoint.BNThermicoffersachoiceoftwothermostats:FST-INandFST-EX.TheFST-EXshouldbeselectedforoutdoorapplicationsorwhereatamperproofdeviceispreferred.Boththermostatshaveaswitchingcapacityof10A.Largerloadscanbeswitchedviaasuitablyratedcontactor.

Notes on Selection and Installation• Usethefollowingtablestoselectthecorrectoutputandlengthofcablerequiredforyour

application.Youwillnoticethatinmostinstancesastraightrunofcablewillsuffice.Thetablealsoindicatesthethicknessoftheinsulationwhichshouldcoverbothpipeandcable.

• ACRJ-T1terminationkitwillberequiredpercircuitwithoneCRJ-SsplicekitrequiredforeveryspliceorTjoint

• Securethecabletothepipeat200mmintervalsusingPF-Tfixingtape• PlasticpipesshouldbewrappedinAL50aluminiumtapebeforeinstallingthecable• Maximumcircuitlengthsareasfollows:

CRJ-10:205mCRJ-25:126m

• BNThermicPF-Lwarninglabelsshouldbeappliedtotheoutsideoftheinsulation

CRJ-T Termination Kit Prepares cable for electrical connection and

seals the ‘far end’

CRJ-S Splice kit for joining two lengths of cable or for making

a ‘T’ joint

PF-L Caution Labels applied to the exterior of the

insulation

FST-IN Thermostat for

indoor use

FST-EX IP65 Thermostat for outdoor use

Page 23: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 23

PIPE FREEZE & GUTTER PROTECTION

CRJ Pipe Freeze protection Cable - SpecificationsModel Volts W/m DescriptionCRJ-10 230 10 10W/mcable-bythemetreCRJ-25 230 25 25W/mcable-bythemetre

CRJ Accessories - PricesModel DescriptionCRJ-T1 TerminationkitCRJ-T5 Terminationkitpackof5CRJ-S Splice/TjointkitPF-L Cautionlabelpackof10PF-T FlameRetardantFixingTape33mx19mmAL-50 45mx50mmaluminiumtape

Recommended frost thermostatsModel Description Full Details

on pageFST-IN FrostThermostatIndoorUse(10A) 65FST-EX FrostThermostatOutdoorUse(10A) 66

CRJ Selection Table 1(minimumambienttemperature-20°C)

Pipe Diameter

(mm)

Insulation Thickness (mm)12 25 50

12 CRJ-10Straight CRJ-10Straight

CRJ-10Straight

25 CRJ-25Straight CRJ-10Straight

CRJ-10Straight

50 CRJ-25Straight CRJ-10Straight

CRJ-10Straight

75CRJ-25

1.3mcable/1mpipe

CRJ-25Straight

CRJ-10Straight

100CRJ-25

1.8mcable/1mpipe

CRJ-25Straight

CRJ-25Straight

150CRJ-25

3mcable/1mpipe

CRJ-25 1.4m

cable/1mpipe

CRJ-25 1.2m

cable/1mpipe

CRJ Selection Table 2(minimumambienttemperature-20°C)

Pipe Diameter

(mm)

Additional Cable Length (m) Pair of Flanges

Valve Support

12 0.23 0.10 0.1025 0.28 0.15 0.1050 0.30 0.30 0.1575 0.45 0.40 0.15

100 0.60 0.50 0.20150 0.80 0.60 0.25

CRJ Self Regulating Cable - Dispensed by the metre

PF-T Fixing TapeSecures CRJ to pipe

Page 24: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143224

PIPE

FRE

EZE

& G

UTTE

R PR

OTEC

TION

PW Pre-terminated Water Pipe Freeze Protection Cable• Prevents water from freezing in metal and plastic pipes• Avoids the cost and inconvenience of burst pipes• Simple low cost product for quick installation.

Typical Applications• Idealforusewithcondensingboilers• Suitableforbothdomesticandcommercialapplications• Widelyusedonmobilehomes.

Features• Pre-terminatedwith1.5mcoldleadandUK3-pinplug• Built-inthermostatautomaticallyenergisesthecablewhenpipetemperaturefallsbelow3⁰C• Profiledthermostatbaseensuresexcellentheattransferfrompipe• Fullymoistureproof.

Controlling PW Pipe Freeze Protection CableThePW’sbuilt-inthermostatmeansthatnoadditionalcontroldeviceisrequired.

Notes on Selection and Installation• Assumingaminimumambienttemperatureof-15⁰Cand20mmthickinsulation

aPWheatingcablecanbeinstalledinastraightlinealongpipesupto50mmdiameter

• AlwaysselecttheshortestsuitablecablefromthePWrange• Wherethecableislongerthanthepipeitisprotecting,windthecableina

gentle,evenlyspacedhelix• Securethecabletothepipeat300mmintervalsusingPF-Ttape• Theentireinstallationincludingthethermostatshouldbecoveredwitha

maximumof20mmthickflameretardantinsulation• Ensurethatthethermostatispositionedatthecoldestendofthepipe• PlasticpipesshouldbewrappedinAL50aluminiumtapebeforeinstallingthe

cable• Whenusedwithpipesthatmaybeempty,thecableshouldbecoveredinalayerof

AL50aluminiumtapebeforetheinsulationisapplied.Atypicalexamplewouldbewhenusedwithacondensingboiler

• PWcablesmustnotbeexposedtotemperaturesinexcessof66⁰C• PF-Lwarninglabelsshouldbeappliedtotheoutsideoftheinsulation.

PW Pipe Freeze Protection Cable - SpecificationsModel Volts Watts Heated Length (m) Weight (kg)PW-01 230 12 1 0.4PW-02 230 24 2 0.5PW-03 230 36 3 0.6PW-04 230 48 4 0.7PW-06 230 72 6 0.8PW-10 230 136 10 1.0PW-14 230 152 14 1.2PW-21 230 281 21 1.5PW-30 230 337 30 2.2PW-42 230 490 42 2.8PF-L Cautionlabelpackof10AL50 45mx50mmaluminiumtapePF-T FlameRetardantFixingTape33mx19mm

PW-06 with built-in thermostat and UK plug

AL50 Aluminium Tape for use with plastic pipes

PF-T Fixing Tape secures PW tape to pipe

PF-L Caution Labels applied to the exterior of the

insulation

PW Water Pipe Freeze Protection Cable a low price for peace of mind

Page 25: BN Thermic 2013-2014 Electric Heating Catalogue

Comm

ercial and Industrial Heaters and Controls

Commercial and Industrial Heaters and Controls

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432

Page 26: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143226

FAN

ASSI

STED

HEA

TERS

SCH Fan Assisted Heaters for 600 x 600 Ceiling Grid• Providing warm inviting commercial premises• Ceiling mounting position allows free use of floor and wall space, an important

consideration in retail premises• First class whole life value from a product built to the highest possible

standard and designed to give many years of trouble free service• Low running costs by selecting from a range of control

options• Specifically designed for quick hassle free

installation

Typical Applications• Shops • Changingrooms• Entrance areas

Features Common to all Models• Insertdepthonly153mm• DesignedtorestintheTbarofa600x600suspended

ceiling grid• Airinletandoutletthroughfrontpanel–norequirementforairsupplyfromtheceilingvoid

• Whitealuminiumegg-cratediffuser• Pre-wiredtorearmountedterminalenclosure• Auto-resetover-temperatureprotection• Simplereductioninoutputbyremovaloflinkinrearmountedenclosure (3kWreducedto2kW,4.5kWreducedto2.25kW)

Controlling SCH Heaters

SCHG-30 3kW HeaterTheSCHG-30canbecontrolledbyaCS-1wall-mountedcontroller(seeoppositepage).TheCS-1shouldbepositionedinaconvenientlocationandprovideson/off/highheat/lowheat/fan-onlysettings.WherethermostaticcontrolispreferredwerecommendthetamperproofRST-TP.TheRST-TP’stamperproofdesignpreventscasualadjustmentoftemperaturesetting.

SCHG-30E 3kW Heater with Built-In ThermostatTheSCHG-30Ehasabuilt-inelectronicthermostatwitharearmountedadjustmentknob.Onceenergised,thefanwillruncontinuouslywhilethethermostatwillmonitortheincomingairtemperatureandadjusttheheatoutputaccordingly.WhereadditionalmanualcontrolisrequiredaCS-1wallmountedcontrollershouldbeused(seeoppositepage).TheCS-1shouldbepositionedinaconvenientlocationandprovideson/off/highheat/lowheat/fan-onlysettings.

SCHG-45 4.5kW HeaterTheSCHG-45canbecontrolledbyaCS-1wall-mountedcontroller(seeoppositepage).TheCS-1shouldbepositionedinaconvenientlocationandprovideson/off/highheat/lowheat/fan-onlysettings.AlternativelythermostaticcontrolcanbeprovidedbyaremotemountedRST-TPtamperproofthermostat.TheRST-TP’stamperproofdesignpreventscasualadjustmentoftemperaturesetting.

153210

406188

airflowdirection

600

optionalmountingbrackets

SCH Dimensions - note NEW low profile designHeight reduced from 210mm to 153mm

SCH heater installed in a suspended ceiling allowing free use of floor and wall space

Page 27: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 27

FAN ASSISTED HEATERSSCH Fan Assisted Heaters - SpecificationsModel Volts kW Airflow

m³/hControls Weight

(kg)Recommended

Mounting Height (m)SCHG-30 230 3.0 220 Remote(selectoption) 9 2.5-3.0SCHG-30E 230 3.0 220 Built-inElectronic

Thermostat9 2.5-3.0

SCHG-45 230 4.5 330 Remote(selectoption) 10 3.0-4.0

Optional Remote Mounted Control DeviceModel Description Full Details

on PageCS-1 ControllerforallSCHmodels 67RST-TP TamperproofThermostat20A 67

CS-1 Controller Providing on/off/high

heat/low heat/fan only settings

FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR CHS SYSTEM - See PAGE 28

Rear view of SCHG-30E – rear mounted terminal enclosures allow quickest possible electrical

connections

SCHG-30 installed in a charity shop in Calverton, Notts

SCHG-30 and diffuser designed for quick installation into a 600 x 600 ceiling grid

RST-TP Energy Saving Tamperproof

Thermostat

Page 28: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143228

FAN

ASSI

STED

HEA

TERS

CHS System Multi-heater System for 600 x 600 Ceiling Grid• Fastest possible installation time for a multi-heater

system• Efficient and economic temperature control without

the need for external contactors or relays• Providing warm inviting commercial premises• Ceiling mounting position allows free use of floor and

wall space, an important consideration in retail premises• First class whole life value from a product built to the

highest possible standard and designed to give many years of trouble free service

Typical Application• Largerretailoutletsrequiringanumberofheaters

The CHS SystemTheCHSsystemallowsagroupofceilingheaterstobecontrolledbyasingleCS-1remotemountedcontrollerand/orasingleremotemountedthermostat.TheCHSsystemcomprisesone‘master’heaterandanyquantityof‘slave’heaters.

Features• DesignedtorestintheTbarofa600x600suspendedceilinggrid• Airinletandoutletthroughfrontpanel–norequirementforairsupplyfromtheceilingvoid• Whitealuminiumegg-cratediffuser• Pre-wiredtorearmountedterminalenclosures• Auto-resetover-temperatureprotection• InsertDepthonly153mm• Simplereductionofoutputto2kWbyremovaloflinkinrearmountedenclosure

CHS Multi-Heater System - SpecificationsModel kW Master/Slave Recommended

Mounting Height (m)CHS-30M 3.0 Master 2.5-3.0CHS-30S 3.0 Slave 2.5-3.0

Control Device OptionsSelectCS-1wallmountedcontrollerand/orfromachoiceoftwothermostats

CS-1ACS-1wall-mountedcontrollerprovideson/off/highheat/lowheat/fan-onlysettings.ItcanbeusedasthesolemeansofcontrollingaCHSsystemorinconjunctionwithaTamperproofThermostatorPROSTAT-7ProgrammableThermostat.

Choiceoftamperproofthermostatorprogrammablethermostat

CS-1 Controller (HighHeat,LowHeat,Fan-only)

OR

Selectasmanyslaveheatersasrequired

Control a CHS System using a choice of tamperproof thermostat or programmable thermostat and/or a CS-1 Controller

CHS-30MMASTER

CHS-30SSLAVE

CHS-30SSLAVE

CHS heater installed in a 600 x 600 ceiling grid as part of a multi-heater system

Page 29: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 29

FAN ASSISTED HEATERSRST-TP Tamperproof ThermostatTheRST-TPTamperproofThermostatprovidesextremelyaccuratetemperaturecontrol.TheRST-TP’stamperproofdesignpreventscasualadjustmentofthetemperaturesetting.TheRST-TPcanbeusedasthesolemeansofcontrollingaCHSsystemorinconjunctionwithaCS-1controller.

PROSTAT-7ThePROSTAT-7isa7-dayprogrammablethermostat.All7dayscanbeindividuallyprogrammedwithupto6settingsperday.Thethermostatispoweredby3xAAbatteries(supplied).ThePROSTAT-7canbeusedasthesolemeansofcontrollingaCHSsystemorinconjunctionwithaCS-1controller.

Remote Mounted Control Devices for a CHS SystemModel Description Full Details on PageCS-1 Remotemountedcontroller 67RST-TP HardCaseTamperproofThermostat20A 67PROSTAT-7 7dayprogrammableThermostat 66

Rear view of CHS-30M showing terminal

enclosures allowing quick and easy

connection to any number of slave heaters

Rear view of CHS-30S showing terminal enclosures

Removal of a link from the larger enclosure reduces output to 2kW

PROSTAT-7 7-day programmable

thermostat for maximum economy

CS-1 Controller Providing on/off/high

heat/low heat/fan only settings

RST-TP Energy Saving Tamperproof

Thermostat

Page 30: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143230

FAN

ASSI

STED

HEA

TERS

• Providing warm inviting commercial premises• Smart modern appearance• First class whole life value from a product built to the highest possible

standard and designed to give many years of trouble free service• Low running costs by selecting from a range of control options

Typical Applications• Overdoorheatinginshopsandcafes• Spaceheatinginawidevarietycommercialpremises

Features Common to all Models• Dualfunctionbracketforverticaldischarge(overdoor)orangled

discharge(generalspaceheating)• Attractivewhite(RAL9010)finish• Auto-resetover-temperatureprotection• Panelfronton/offswitch• Pre-wiredtorearmountedterminalenclosures• Simplereductioninoutputbyremovaloflinkinrearmountedenclosure

(3kWheaterreducedto2kWand6kWheaterreducedto4kW)• SuitableforusewithCS-1remotemountedcontrollerproviding

on/off/highheat/lowheat/fanonlysettings

Controlling the 800 Series

830 3kW and 860 6kWControl mode 1 – Simple on/off controlSimplecontrolusingpanelfronton/offswitch

Control mode 2 – Remote ThermostatThermostaticcontrolusinganRST-TPremotemountedtamperproofthermostat,connectedintotherearmountedterminalenclosure.TheRST-TP’stamperproofdesignpreventscasualadjustmentoftemperaturesetting.

Control mode 3 – Remote controllerControlisprovidedbymeansofaremotemountedCS-1controlboxwhichisconnectedintotherearmountedterminalenclosure.TheCS-1controllerprovideson/off/highheat/lowheat/fanonlysettings.

800 Series High Level Wall or Overdoor Fan Assisted Heaters

830 as an overdoor heater

830T wall mounted as Space Heater

The complete 800 Series

830

830T

860T

860

Rear views of 800 Series showing rear mounted terminal enclosures. These provide:• Easy power connection• Simple means of reducing output by removal of links• Quick connection to optional remote control devices.

Page 31: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 31

FAN ASSISTED HEATERS

CS-1Providing on/off/high heat/low heat/fan only settings

RST-TP Energy Saving Tamperproof

Thermostat

Control mode 4 – Combination of Remote Thermostat and Remote ControllerBothremotemountedRST-TPtamperproofthermostatandremotemountedCS-1controllerareconnectedintotherearmountedterminalenclosure.TheRST-TP’stamperproofdesignpreventscasualadjustmentoftemperaturesetting.TheCS-1controllerprovideson/off/highheat/lowheat/fanonlysettings.

830T 3kW with built-in thermostat and 860T 6kW with built-in thermostatControl mode 1 – Built-in thermostatic controlOn/offcontrolisprovidedbyapanelfrontswitchwiththermostaticcontrolprovidedbythebuilt-inelectronicthermostat.Thermostatset-pointadjustmentisbymeansofapanelfrontknob.Oncethetemperatureset-pointisreached,thethermostatwillswitchoffboththeheatingelementandthefan.

Control mode 2 – Combination of built-in thermostatic control and remote controllerThermostaticcontrolisprovidedbythebuilt-inelectronicthermostat.Thermostatset-pointadjustmentisbymeansofapanelfrontknob.Oncethetemperatureset-pointisreached,thethermostatwillswitchoffboththeheatingelementandthefan.AremotemountedCS-1controllerisconnectedintotherearmountedterminalenclosure.TheCS-1controllerprovideson/off/highheat/lowheat/fanonlysettings.

800 Series - SpecificationsModel Volts kW Integral Controls Dimensions (mm) Weight (kg)

H W D830 230 3.0 On/OffSwitch 225 635 108 7830T 230 3.0 On/OffSwitch&Electronic

Thermostat225 635 108 7

860 230 6.0 On/OffSwitch 225 1105 108 14860T 230 6.0 On/OffSwitch&Electronic

Thermostat225 1105 108 14

Optional Remote Control DevicesModel Description Full Details

on PageCS-1 Wall-MountedController 67RST-TP TamperproofThermostat20A 67

800 Series heater

800 Series heater

800 Series heater

Optional Tamperproof Thermostat*

Optional CS-1 Controller Providing on/off/high heat/low heat/fan only settings

Optional CS-1 Controller Providing on/off/high heat/low heat/fan only settings

Optional Tamperproof Thermostat*

Control Options for 800 Series Fan Assisted Heaters

* This control option is not available to models 830T and 860T as these heaters have

an integral thermostat

830T installed over a shop door

Page 32: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143232

FAN

ASSI

STED

HEA

TERS

HCA Air Curtain• Providesaninvisiblebarrieracrossentrancestocommercialpremises• Reducesheatingandairconditioningcosts• Minimisestheingressofpollutants

Typical Applications• Shops• Offices• Hospitals• Hotels

Features• SturdysteelcasewithwhiteRAL9010satinfinish• Wall-mountingplatesuppliedasstandard,alternativelytheunitcanbesuspendedfromdroprods (4xM6threadedholesareprovidedinthetopoftheunit).

• Remotemountedcontrolboxwiththefollowingsettings: On Off Lowairflow/Noheat HighAirflow/Noheat LowAirflow/lowheat Highairflow/lowheat HighAirflow/highheat• Automaticandmanual-resetover-temperaturesafetydevices• Recommendedmountingheight2.2mto2.7m

SpecificationsModel Volts kW Airflow(m³) Dimensions (mm) Weight

Low High Low High H W D (kg)HCA-09 400/3N 4.5 9.0 1444 1879 254 1113 265 19.6HCA-13 400/3N 6.75 13.5 2441 2617 254 1621 265 25.4HCA-18 400/3N 6.0 18.0 3834 4100 254 2121 265 31.9

Sturdy wall-mounting-plate supplied as standard

Remote mounted control box for high/low airflow and heat

HCA air curtain reduces heating costs

Page 33: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 33

FAN ASSISTED HEATERSEFC Fan Convector Heater• Providingcomfortheatincommercialbuildingsandpublicareas

• ExceptionalBuildqualityforlonglifeandpeaceofmind

Typical Applications• CommunityHalls• Schools• Entrance Areas• Corridors

Features• Superrobuststeelcasewithroundedcorners• Keylockablefrontpanel(keyprovided)• Powerfulfanmotorensuresquickwarmupandeventemperaturedistribution

• ‘Pencilproof’inletandoutletgrille• Overtemperatureprotection• DedicatedMCBsforheatingelementsandfanmotor• Sidemountedswitchforon/offandhigh/lowcontrol• Stylishgreyfinishwithblackgrilles• Terminalsforconnectiontoremotethermostat(werecommendourRST-TPtamperproofthermostat)

Optional PlinthTheEFC-06canbesuppliedwithanoptional100mmhighplinth.Theplinthispaintedblacktomatchinletandoutletgrilleandoffersthefollowingadvantages.• Reducesthechanceofdustbeingdrawninthroughthe

inlet grille• Allowsforeasierfloorcleaning• Createsarecessforstandardheightskirtingboard

Controlling an EFC-06Thesidemountedswitchprovideson/off/high/lowsettings.Typicallythe‘high’(6kW)settingwouldbeselectedinitiallyforthequickestpossiblewarmup.Onceanacceptabletemperaturehasbeenachieved,theheatercanbeswitchedto‘low’(3kW).Thiswillreducebothrunningcostsandnoise.ApproximatedBlevelsareasfollows:HighSetting:45.7dB.LowSetting:32.4dBToensuremaximumeconomytheEFC-06shouldbecontrolledbyaremotewall-mountedthermostat.WerecommendourRST-TPtamperproofthermostatwhichpreventscasualadjustmentoftemperatureset-point.

SpecificationsModel Volts High Setting Low Setting Dimensions (mm) Weight

kW m³/h kW m³/h H W D (kg)EFC-06 230 6.0 540 3.0 378 675 895 230 45EFC-P Optional100mmblackplinthRST-TP Recommendedremotemountedtamperproofthermostat(seepage67)

EFC-06 with optional plinth fitted

EFC-06 Fan Convector: robust construction for public areas

Page 34: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143234

FAN

ASSI

STED

HEA

TERS

RH Recessed Fan Assisted Heaters• Providing warm inviting commercial premises• Choice of ceiling or wall mounting allows free use of floor and wall

space, often an important consideration• First class whole life value from a product built to the highest possible

standard and designed to give many years of trouble free service• Low running costs by selecting from a range of control options

Typical Applications• Overdoorheatinginshopsandcafesespeciallywhereitisnotpracticalordesirabletoinstallconventionalwall-

mountedheater• Spaceheatinginawidevarietyofcommercialpremises• Changingrooms• Entrance areas

Features Common to all Models• Airinletandoutletthroughfrontpanel–norequirement

forairsupplytotherearoftheheater• Whitealuminiumegg-crategrille• Pre-wiredtorearmountedterminalenclosure• Auto-resetover-temperatureprotection• Simplefixingthroughthefaceoftheheater• Suitableforverticalorhorizontaldischarge

Controlling the RH SeriesControl mode 1 – Simple on/off controlSimplecontrolusingremoteisolatingswitch

Control mode 2 – Remote Tamperproof ThermostatAnRST-TPremotemountedtamperproofthermostat.TheElectronicControlThermostatisconnectedintotherearmountedterminalenclosure.TheRST-TP’stamperproofdesignpreventscasualadjustmentoftemperaturesetting.

Control mode 3 – Remote controllerControlisprovidedbymeansofaremotemountedCS-1controlboxwhichisconnectedintotherearmountedterminalenclosure.TheCS-1controllerprovideson/off/highheat/lowheat/fanonlysettings

Control mode 4 – Combination of Remote Thermostat and Remote controllerBothremotemountedtamperproofthermostatandremotemountedCS-1controllerareconnectedintotherearmountedterminalenclosure.TheRST-TP’stamperproofdesignpreventscasualadjustmentoftemperaturesetting.TheCS-1controllerprovideson/off/highheat/lowheat/fanonlysettings

RH-303kW recessed heater commonly

installed above a door

RH-20Extremely compact 2kW

recessed heater

RH-606kW recessed heater with

integral contactor

Rear view of RH-30External enclosures allowing the quickest

possible electrical connections

Page 35: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 35

FAN ASSISTED HEATERS

RH DimensionsModel A (mm) D (mm)RH-20 363 307RH-30 597 550RH-60 1198 1138

RH Recessed Fan Assisted Heaters - SpecificationsModel Volts kW Airflow

(m³/h)Aperture Size (mm)

Insert Clearance (mm) Weight (kg)

RH-20 230 2.0 120 315x150 200 3.3RH-30 230 3.0 250 560x150 200 4.2RH-60 230 6.0 500 1148x150 230 11

Optional Remote Mounted Control Devices for the RH RangeModel Description Full Details on PageCS-1 ControllerforallRHmodels 67RST-TP TamperproofThermostat20A 67

CS-1 Controller Providing on/off/high

heat/low heat/fan only settings

RH Series heater

RH Series heater

Optional Tamperproof Thermostat

Optional CS-1 Controller Providing on/off/high heat/low heat/fan only settings

Optional CS-1 Controller Providing on/off/high heat/low heat/fan only settings

Optional Tamperproof Thermostat

RH Series heater

Control Options for RH Recessed Fan Assisted

Heaters

RST-TP Energy Saving Tamperproof

Thermostat

Page 36: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143236

FAN

ASSI

STED

HEA

TERS

OUH Unit Heaters• Providing an efficient means of heating large industrial premises• Exceptional reliability – backed by 5 year warranty• The most robust industrial unit heater available

Typical Applications• Warehouses• WorkshopsTheinstalledloadmustexceedtheheatlossfromtheentirearea.OUHunitheatersarespaceheaters–theyareNOTsuitablefor‘spotheating’.

Features Common to all Models• FIVEYEARWARRANTY• Integral contactor and fused control circuit• Heavygaugesteelconstructionwithalmond(RAL9001)finish• Adjustablelouvers• Wallandceilingbracketssuppliedasstandard• Optionalsuspensionkit(OUH-J)• Optionaldiffuser(OUH-CD)forusewithsuspendedheaters;aids

heatdistribution• Optionalfactoryfittedbuilt-inthermostat(OUH-TH-16)• Terminalssuppliedforeasyconnectiontoremotecontroldevices• Auto-resetover-temperatureprotection

5

Controlling OUH HeatersOUHheatersarebestcontrolledusingaTamperproofElectronicControlDevicefromBNThermic’sHardCaserange.HardCase’stamperproofdesignensuresthatonlyauthorisedpersonnelcanadjustthetemperaturesetting.EachheaterwillbecontrolledbyanindividualHardCaseThermostatgenerallymountedimmediatelybelowtheheateratapproximately1.5mabovefloorlevel.Thisisanenergysavingapproachallowingthecontrolsystemtotakeintoaccountdifferingconditionsindifferentpartsofthebuilding.TheuseofdedicatedThermostatsalsokeepsinstallationtimetoaminimum.

We offer 3 control packagesStandard Control PackageProgrammable PackageProgrammable Package with Set-Back

OUH Unit Heater suspended and fitted with optional diffuser for

improved heat distribution

Mounting options with brackets provided

OUH Unit Heater – Robust, Rugged, Reliable

OUH Unit Heater wall mounted in a vehicle repair shop

Page 37: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 37

FAN ASSISTED HEATERSStandard Control Package• ControlisbymeansofaHardCaseHC-T2TamperproofElectronicControl

Device• AccesstotemperatureadjustmentrequiresanHC-Dtoolensuringthatonly

authorisedpersonnelcanadjustsettings• Anintegralswitchallowsauthorisedpersonneltoselectbetweentwo

temperaturescales:0-12⁰Cforfrostprotectionor12-25⁰Cforcomfortheating.

ComponentsHC-T2HardCaseTamperproofElectronicControlDevice(oneperheater)HC-DHardCaseTool(requiredtoaccesstemperaturesettings)

Programmable Package• ControlisbymeansofaHardCaseHC-T2TamperproofElectronicControlDevice• AccesstotemperatureadjustmentrequiresanHC-Dtoolensuringthatonlyauthorisedpersonnelcanadjust

settings• Anintegralswitchallowsauthorisedpersonneltoselectbetweentwotemperaturescales:0-12⁰Cforfrost

protectionor12-25⁰Cforcomfortheating.• ATIM-D124hour/7dayprogrammabletimerwillensurethattheheatingsystemisnotenergisedwhilethe

buildingisunoccupied(typicallyatnightandatweekends).• Theprogrammabletimerhasabuilt-inrun-downclockthatistriggeredbytheTIM-B1remotemounted‘boost

button’.Thisfeaturewillprovideatemporarytemperatureboostforapre-determinedlengthoftimeduringaperiodwhenthesystemwouldnormallybe‘off’.Theboostcommandcanbecancelledbydepressingthe‘boostbutton’for3seconds.

ComponentsHC-T2TamperproofElectronicControlDevice (oneperheater)HC-D-HardCaseTool(requiredtoaccesstemperaturesettings)TIM-D1ProgrammableTimerTIM-E1TimerEnclosure

TIM-B1 BoostButton

Programmable Package with Set-Back• ControlisbymeansofaHardCaseHC-ST2TamperproofElectronicControlDevice• AccesstotemperatureadjustmentrequiresanHC-Dtoolensuringthatonlyauthorisedpersonnelcanadjust

settings• TheHC-ST2hastwoadjustablesettings:high(comfort)andlow(set-back).• ATIM-D124hour/7dayprogrammabletimerwillensurethattheheatingsystemoperatesatitslow(set-back)

settingwhilethebuildingisunoccupied(typicallyatnightandatweekends).• Theprogrammabletimerhasabuilt-inrun-downclockthatistriggeredbytheTIM-B1remotemounted‘boost

button’.Thisfeaturewillprovideatemporarytemperatureboostforapre-determinedlengthoftimeduringaperiodwhenthesystemwouldnormallybeinset-backmode.Theboostcommandcanbecancelledbydepressingthe‘boostbutton’for3seconds

ComponentsHC-ST2TamperproofElectronicControlDevice withSet-Back(oneperheater)HC-D-HardCaseTool(requiredtoaccesstemperaturesettings)TIM-D1ProgrammableTimerTIM-E1TimerEnclosureTIM-B1 BoostButton

HC-T2Tamperproof thermostat

OUHUnit Heater

Additional thermostat(s) Additional heater(s)

TIM-B1Push Button

For temporary boost

TIM-D1Programmable

timer

HC-T2Tamperproof

thermostat

OUHUnit Heater

Additional thermostat(s) Additional heater(s)

TIM-B1Push Button

For temporary boost

TIM-D1Programmable

timer

HC-ST2Tamperproof

thermostat

OUHUnit Heater

Additional thermostat(s) Additional heater(s)

Page 38: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143238

FAN

ASSI

STED

HEA

TERS

OUH Unit Heaters - SpecificationsModel Volts kW Airflow (m³/h) Dimensions (mm) Weight (kg)

H W DOUH-03-1 230 3 1180 305 420 432 23OUH-03-3 400/3N 3 1180 305 420 432 23OUH-05-1 230 5 1180 305 420 432 23OUH-05-3 400/3N 5 1180 305 420 432 23OUH-07-1 230 7.5 1180 305 420 432 23OUH-07-3 400/3N 7.5 1180 305 420 432 23OUH-10 400/3N 10 1180 305 420 432 23OUH-15 400/3N 15 2200 444 560 572 35OUH-20 400/3N 20 2200 444 560 572 35OUH-25 400/3N 25 2200 444 560 572 35Optional factory fitted thermostat 5⁰C to 35⁰C - Add 'T' suffix to model code above 0.3OUH-J Jhooksforverticalsuspension(setof4) 2.0OUH-CD1 Diffuserforsuspendedheater3kWto10kW 4.0OUH-CD2 Diffuserforsuspendedheater15kWto25kW 7.0

PLEASE CONTACT BN THERMIC FOR NON-STANDARD VOLTAGES

Hard Case ThermostatsModel DescriptionHC-T2 TamperproofElectronicControlDeviceHC-ST2 TamperproofElectronicControlDeviceswitchingbetweenhighandlowsettings

usingremotetimer(TIM-D1)HC-D TamperproofToolforHardCase(HC)range

AllHardCasemodelshavetheoptionofaremotesensor(seepage62)

TimerModel DescriptionTIM-D1 ProgrammabletimerTIM-E1 TerminalenclosureforTIM-D1timerTIM-B1 PushButtonforusewithTIM-D1(providestemporaryboost)

OUH Continued

HC-T2 Energy Saving Tamperproof Electronic Control

Device HC-D Tamperproof Tool for Hard Case Electronic Control Devices, ensuring that

only authorised personnel can adjust temperature settingsHC-ST2 Tamperproof Electronic Control Device

with two adjustable set-points

TIM-D1 programmable

timer fitted into TIM-E1 enclosure with memory card and optional PIN

protection

TIM-B1 Push Button providing temporary temperature boost when used with a TIM-D1 timer

Page 39: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 39

FAN ASSISTED HEATERSDSU Destratification Units• Reducing heating bills by up to 30% by recycling warm air

that has collected at high level.• Recommended for industrial premises where roof height

exceeds 4m

Typical Applications• Warehouses• ExhibitionHalls• IdeallysuitedforuseinconjunctionwithBNThermic’sOUHIndustrialUnitHeaters

Features • Reducesheatingcostsbyupto30%• Heavydutysteelconstruction• Built-inthermostatautomaticallyenergisesfan• 4-wayadjustablelouvers• Suspensionkitsuppliedasstandard(4x500mmchainsandassociatedhooks)

DSU Destratification Units - SpecificationsModel Volts Airflow

(m³/h)Dimensions (mm) Mounting

Height (m)Area Covered (m) Weight (kg)

H W DDSU-4 230 4000 385 560 560 4to7 20x20 18DSU-8 230 8000 385 720 720 7to12 25x25 24

Without DSUWarmairaccumulatesat

high level

Reduces energy costs when roof height exceeds 4m

With DSUWarmairisrecycledreducingheatingcosts

byupto30%

Warehouse Example

DSU-4 installed in a vehicle repair shop in Kent

Page 40: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143240

FAN

ASSI

STED

HEA

TERS

HC-T2 Energy Saving Tamperproof Electronic

Control Device

HC-D Tamperproof Tool for HC-T2Ensuring that only authorised

personnel can adjust temperature settings

Remote Electronic Control DeviceModel Description Full Details

on PageHC-T2 Hard Case Electronic Control Device 16A 62HC-D TamperproofToolforHardCase(HC)Range 62ThistableonlyshowsthebasicHC-T2HardCaseElectronicControlDevice.HoweveritispossiblethatanalternativemodelfromtheHardCaseRangemaybemoresuitableforanygiveninstallation.Pleaseseepage62forfulldetailsoftheHardCaserange.

WHE Compact Heavy Duty Wall Mounted Fan Assisted Heaters• Providing warmth in public areas and industrial installations• Exceptional reliability – backed by 5 year warranty• Ideally suited to applications where space is limited• Low running costs by selecting from a range of control options

Typical Applications• Cranecabs• TollBooths• Workshops

Features Common to all Models• FIVEYEARWARRANTY• Canbemountedverticallyorhorizontally• Heavygaugesteelconstructionwithalmond(RAL9001)finish• CanberecessedorsurfacemountedwithoptionalWHE-SBsurfacemountbox• Auto-resetover-temperatureprotection

Controlling WHE HeatersThermostaticcontrolishighlyrecommended.Thisisgenerallyachievedbymeansofabuilt-inthermostat(WHE-TB)whichcanbemadetamperproofifrequired.WhereremotethermostaticcontrolispreferredwerecommendourtamperproofHardCaseRangeofElectronicControlDevices(seebelow).HardCase’stamperproofdesignensuresthatonlyauthorisedpersonnelcanadjustthetemperaturesetting.

WHE Fan Assisted Heaters - SpecificationsModel Volts kW Airflow

(m³/h)Dimensions (mm) Weight (kg)

H W DWHE-2024 230 2.0 135 406 206 108 4WHE-1512 110 1.5 135 406 206 108 4WHE-SB OptionalSurfaceMountBox 407 206 76 1Optional built-in thermostat - Add 'T' suffix to model code 0.3

5

WHE in optional surface mount box Tough and Compact

4 alternative mounting configurations

Page 41: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 41

CONVECTION HEATERSBLC Pew Heaters• Providing an unobtrusive and economic means of heating a church

Heating in ChurchesHeatingaconventionalchurchpresentsmanyproblemstoovercome.• Thelargevolumemeansthatmaintainingacomfortableairtemperatureisextremelyexpensive.• Towarmuptheairfrom‘cold’priortoeachservicewouldtakeaverylongtime,consumeagreatdealofenergy

andisnotgenerallyregardedasapracticalsolution.• Inmanychurchesitisnotpermissibletofitheaterstowallsorsuspendthemfromthe

roof.• Anysourceofheatneedstobesilentandasunobtrusiveaspossible.

Wherefixedpewsareinplace,theBLCrangeprovidesthebestmethodofheatinginachurch.Theheatersshouldbefixedtotheback-boardofthepewbelowtheseat.

• BLCPewheatersprovidedirectheattothepeoplesittinginthepews.Asnoattemptismadetobuildupabodyofwarmairwithinthechurch,theheaterscanbeswitchedonminutesbeforeaservicestartsandswitchedoffimmediatelyitfinishes.

• BLCPewheatersareextremelyunobtrusive.Wheninstalledunderatraditionalpewtheyarebarelynoticeable.

• NaturalconvectionheaterssuchastheBLCaresilentandwithno movingpartsrequirelittlemaintenance.

• AstheBLCisadirectsourceofheat,onlyoccupiedpewsneedto beheated.

Features• Robuststeelconstructionwithcentralbaffleplatetopromote convection

currents• Longlifemetalsheathedfinnedheatingelement• Darkbrownpaintfinish• Auto-resetover-temperatureprotection• Terminalenclosureonrighthandsideforeasyelectricalconnection• Optionalsafetyguardswithdarkbrownfinish-neweasy-fitdesign• Optionalfloormountingbracketswithdarkbrownfinish

BLC mounted undera church pew

BLC Series - ideal for unobtrusive

installation under a church pew

BLC-300B

BLC-500B

BLC-750B

BLC heaters installed under pews in St Bartholomew’s Church Notgrove

Page 42: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143242

CONV

ECTI

ON H

EATE

RS

Controlling BLC Heaters in a Church ControllingBLCheatersinachurchisgenerallyassimpleasswitchingontherequiredheatersimmediatelybeforeaserviceandswitchingthemoffoncethepewshavebeenvacated.Thiscanbeachievedmanuallyorbymeansofaprogrammabletimerifpreferred.Itisnotusuallynecessarytousethermostaticcontrolinachurchapplicationasthereisnoattemptbeingmadetobuildupandmaintainabodyofwarmair.

SelectionBLCheatersaredesignedtobefittedontothebackboardbetweentheseatsupportsofachurchpew.Forbestresultstheheatersshouldcoverasmuchofthelengthofthepewaspossible.WhereabackboardisnotavailableBLC-FBfloorbracketswillberequired.Usethefollowingtabletodeterminetherecommendedheaters:

Space Between Pew Seat Supports Recommended HeaterMinimum Maximum650mm 750mm BLC-300B750mm 1000mm BLC-500B1000mm 1500mm BLC-750B1500mm+ Usemultipleheaters

BLC Continued

Spaces between seat supports

BLC Low Level Convector Heaters - SpecificationsModel Volts kW Dimensions (mm) Finish Recommended

GuardWeight (kg)

H W DBLC-300B 230 0.3 148 566 62 Brown BLC-EXG6 3.0BLC-500B 230 0.5 148 691 62 Brown BLC-EXG7 4.0BLC-750B 230 0.75 148 945 62 Brown BLC-EXG10 5.0BLC-FB Floormountingbrackets(pair) Brown - -BLC-EXG6 Safetyguard610mm Brown - -BLC-EXG7 Safetyguard730mm Brown - -BLC-EXG10 Safetyguard1000mm Brown - -

Page 43: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 43

CONVECTION HEATERS

BLS 110V Low Level Convector Heaters

• Providing comfort heat where only a 110V supply is available• Low running costs ensured by integral thermostatic control• Low profile design allows maximum use of wall space

Typical Applications• Site Huts

Features• Robuststeelconstructionwithcentralbaffleplatetopromoteconvectioncurrents• Longlifemetalsheathedfinnedheatingelement• Auto-resetover-temperatureprotection• Built-inthermostatwithexternalknoballowingeasyadjustmentoftemperatureset-point

BLS Low Level Convector Heaters - SpecificationsModel Volts kW Dimensions (mm) Weight

(kg)H W DBLS-110-1000T 110 1.0 148 1206 62 6.0

BLC-FB Floor Mounting BracketsCommonly used in churches where the pews

do not have a conventional back-board

BLC-EXG6 optional safety guard for BLC rangeRedesigned to allow guard to be retro-fitted

BLS-110-1000T 110V robust convector heater – ideal

for site huts

Page 44: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143244

CONV

ECTI

ON H

EATE

RSSWD Industrial Finned Tubular Heaters• Providing background or comfort heat in

damp or corrosive environments• Specifically designed for long

life in the most demanding conditions

• Low running costs by selecting from a range of control options

Typical Applications• Watertreatmentplants• Plantrooms• Liftshafts

Features Common to all Models• Weldedstainlesssteeltubewithstainlesssteelcoolingfins• Stainlesssteelbracketsforfloororlowlevelwallmounting• WaterproofreinforcedglassfibreterminalenclosureconformingtoIP66• M20waterproofcableglandsuppliedasstandard

Controlling SWD HeatersThermostaticcontrolishighlyrecommended.ThesimplestoptionistoselectaheaterwiththeprefixSWD-A.Thisindicatesthatabuilt-inadjustablethermostatisprovided.Thebuilt-inthermostathasaset-pointrangebetween5°Cand30°Candincludesafrostprotectionsetting.WhereremotethermostaticcontrolispreferredwerecommendourtamperproofHardCaseRangeofThermostats(seeopposite).HardCasethermostats’tamperproofdesignensuresthatonlyauthorisedpersonnelcanadjustthetemperaturesetting.ThestandardHardCaseisnotwaterproof,howevertheHardCaserangeincludesandoptionalremotesensorwithanIP55rating.TheHardCaseHC-T2willswitchasinglephaseloadofupto16Aandlargerloadsor3-phaseloadsviaasuitablyratedcontactor(seepage62)

Safety GuardsWherepersonnelhaveaccesstoanSWDheater,theuseofanSWGsafetyguardisstronglyrecommended.Manufacturedfromheavygaugezincplatedwire,theSWGcomescompletewithmountingclipsforeasyfixingtofloororwall.

SWD mounted under SWG GuardAn SWD guard is recommended when personnel have access to the heaters

SWD Industrial Finned Tubular Heater ideal for damp and

corrosive environments

SWD-U standard formatSWD-A with externally adjustable thermostat

Page 45: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 45

CONVECTION HEATERSSWD Tubular Heaters - SpecificationsModel Control Volts kW Dimensions (mm) Recommended

GuardWeight

(kg)H W DSWD-U-500-1 None 110 0.5 170 440 130 SWG-1 3.0SWD-U-1000-1 None 110 1.0 170 640 130 SWG-2 4.8SWD-U-1500-1 None 110 1.5 170 840 130 SWG-3 6.2SWD-A-500-2 Thermostat 230 0.5 170 440 130 SWG-1 3.0SWD-A-1000-2 Thermostat 230 1.0 170 640 130 SWG-2 4.8SWD-A-1500-2 Thermostat 230 1.5 170 840 130 SWG-3 6.2SWD-A-2000-2 Thermostat 230 2.0 170 1040 130 SWG-3 7.7SWD-A-3000-2 Thermostat 230 3.0 170 1440 130 SWG-4 10.9SWD-U-500-2 None 230 0.5 170 440 130 SWG-1 3.0SWD-U-1000-2 None 230 1.0 170 640 130 SWG-2 4.8SWD-U-1500-2 None 230 1.5 170 840 130 SWG-3 6.2SWD-U-2000-2 None 230 2.0 170 1040 130 SWG-3 7.7SWD-U-3000-2 None 230 3.0 170 1440 130 SWG-4 10.9SWD-U-4000-2 None 230 4.0 170 1840 130 SWG-5 13.7SWD-U-1000-3 None 400/3 1.0 170 640 130 SWG-2 4.8SWD-U-1500-3 None 400/3 1.5 170 840 130 SWG-3 6.2SWD-U-2000-3 None 400/3 2.0 170 1040 130 SWG-3 7.7SWD-U-3000-3 None 400/3 3.0 170 1440 130 SWG-4 10.8SWD-U-4000-3 None 400/3 4.0 170 1840 130 SWG-5 13.7SWG-1 RecommendedGuard 240 450 240 1.0SWG-2 RecommendedGuard 240 650 240 1.5SWG-3 RecommendedGuard 240 1075 240 2.0SWG-4 RecommendedGuard 240 1600 240 3.5SWG-5 RecommendedGuard 240 1900 240 4.0

Remote ThermostatModel DescriptionHC-T2 TamperproofThermostat16AHC-S2 OptionalRemoteWaterproofSensor(IP55)forusewithHC-T2ThermostatHC-D TamperproofToolforHardCase(HC)range

ThistableonlyshowsthebasicHC-T2HardCaseThermostat.HoweveritispossiblethatanalternativemodelfromtheHardCaserangemaybemoresuitableforanygiveninstallation.Pleaseseepage62forfulldetailsoftheHardCaserange.

HC-T2 Energy SavingTamperproof Electronic Control

Device

HC-D Tamperproof Tool for HC-T2Ensuring that only authorised personnel can

adjust temperature settings

HC-S2 SensorOptional remote sensor for use

with Hard Case Tamperproof Electronic Control Devices and

conforming to IP55

Page 46: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143246

RADI

ANT

HEAT

ERS

HWP2 Patio Heater• Providing safe, instant comfort heat in outdoor

locations• Ensures the maximum use of outdoor facilities• Minimal maintenance especially when compared to

gas systems• Low running costs by selecting from a range of control options• Smart modern design complementing external decor

Typical Applications• Patios–bothcommercialanddomestic• Pubgardens• Pavementcafes• Golfdrivingranges• Nightclubqueuingareas• Smokingareas

Features Common to all Models• IP55ratingallowingtheheatertobeinstalledandleftoutdoors

throughouttheyear• Aluminiumconstructionwithstainlesssteelsafetygrille• Highqualityhalogenlampwith7000hoursaverageoperatinglife• Halogenlampiseasilyreplaceable• Choiceofblack,whiteorsilverfinish• Wallmountingbracketandparasolclampsupplied

as standard • Openfronteddesignprovidesa25%increasein

heatingefficiencywhencomparedwithglass-frontedheaters• Convenientrearmountedlugsfacilitatesuspension

Controlling HWP Patio HeatersAsHWPpatioheatersare100%effectivetheinstanttheyareswitchedon,werecommendacontrolsystemthatwillde-energiseaheaterwhenheatingisnotrequired.ThiscanbeachievedbymeansofaPushButtonTimeroraMovementDetector.

Push Button Timer TheBNThermicTS-3isacompact,surfacemount,weatherproofdeviceconformingtoIP66.Asimplepushbuttonwillenergiseaheaterorheatersforapre-programmedperiodbetween2minutesand2hours.Oncethisperiodhaselapsedtheheatingwillbeautomaticallyswitchedoffuntilthebuttonispushedagain.Thedeviceisvandalresistantandtamperproofmeaningonlyauthorisedpersonnelcanadjustthetimesettings.ForfulldetailsoftheTS-3seepage69.

TheTS-3hasaswitchingcapacityof16A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage68).

Movement SensorTheBNThermicWH-402isacompact,surfacemount,weatherproofdeviceconformingtoIP55.TheWH-402willdetectmovementinanareaupto12mfromitsmountingpositionina180°arc.Bothdistanceandangleofdetectioncanbereducedifrequired.Oncemovementhasbeendetected,theheatingwillbeswitchedon.Ifnofurthermovementisdetectedwithinapre-programmedtimeperiod(5secondsto18minutes)theheatingwillbeautomaticallyswitchedoff.ForfulldetailsoftheWH-402seepage69.

TheWH-402hasaswitchingcapacityof16A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

HWP2-B

HWP2-45B

HWP2-W

HWP2-S

WH-402Energy saving device ensuring that heating is switched off when

an area is unoccupied

HWP2-3B

TS-3 Timer Energy saving timer

weather-proof to IP66

Page 47: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 47

RADIANT HEATERSDimmerInspecificapplicationstheremaybeaneedtoadjusttheintensityoftheheatoutputfromaHWPpatioheater.TheBNThermicVR-1providesadjustmentbetween0%and100%ofheateroutput.Italsohasadefinite‘click’tooffallowingittobeusedasanon/offswitch.TheVR-1isasurfacemountdevicebutisnotsuitableforoutdoorsinstallation.ForfulldetailsoftheVR-1seepage69.

TheVR-1hasaswitchingcapacityof13A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.ForlargerloadsmorethanoneVR-1dimmerwillberequired.

Patio Heater SelectionUsethefollowingdiagramandtabletoselecttheoptimummountingposition.Inanexposedlocationandwheremountingheightisrelativelyhigh,werecommendinstallinga2kW,3kWor4.5kWheater.

Heater Output

Wall Mounted

Area Covered

H X Y Z1.5kW 2.0m 2.3m 2.4m 4.0m 7.6m21.5kW 2.5m 3.0m 3.0m 5.2m 12.3m22kW 2.0m 2.3m 2.4m 4.0m 7.6m22kW 2.5m 3.0m 3.0m 5.2m 12.3m23kW 2.0m 2.6m 2.4m 4.5m 8.5m23kW 2.5m 3.4m 3.0m 5.8m 13.8m24.5kW 2.0m 7.5m 2.4m 12.0m 23.4m²4.5kW 2.5m 9.0m 3.0m 15.6m 26.9m²

Area covered by the heaterWall Mounted

X

Y Z

H

HWP2 Patio Heater - SpecificationsModel Volts kW Finish Dimensions (mm) Weight

(kg)H W DHWP2-W 230 1.5 White 120 480 120 1.7HWP2-B 230 1.5 Black 120 480 120 1.7HWP2-S 230 1.5 Silver 120 480 120 1.7HWP2-2B 230 2.0 Black 120 480 120 1.7HWP2-3B 230 3.0 Black 120 960 120 3.2HWP2-45B 230/400 4.5 Black 120 1440 120 6.4

Replacement LampsHeater Output Qty Model Description1.5kW 1 RL15CW 1.5kWClearLamp2kW 1 RL20GW 2kWGoldLamp3kW 2 RL15GW/3 1.5kWGoldLamp4.5kW 1 RL15GW 1.5kWGoldLamp4.5kW 2 RL15GW/4 1.5kWGoldLamp

Optional Remote Mounted Control DevicesModel Description Full Details on PageWH-402 Movementsensor(16A) 69TS-3 Pushbuttontimer(16A) 68VR-1 Dimmer(13A) 69

VR-1Dimmer switch for fine adjustment of

heater output

HWP2 patio heaters providing instant economic heat at the Romans Pub,

Southwick, West Sussex.

Page 48: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143248

RADI

ANT

HEAT

ERS

ETH Terrace Heaters

• Astylishmeansofprovidingatemperatureboostonterracesandpatios• Idealforbothdomesticandcommercialuse• Highqualityconstructionforlonglifeandpeaceofmind

Typical Application• Dining areas• Pavementcafés• BalconiesTerraceheatersareespeciallywellsuitedtopartiallyenclosedareaswheredraughtsarerestricted.InmoreexposedareaswewouldrecommendourHWP2PatioHeaters.ETHTerraceHeatersarealsoperfectlywellsuitedforindoorapplications.

Features• Smartblackappearance• Angleadjustablemountingbracketsprovided• 2mpre-wiredpowercable• Fixingpointsprovidedforsuspension• IP44 rated for outdoor use• No light output

Terrace Heaters - SpecificationsModel Volts kW H W D Weight (kg)ETH-10 230 1.0 45 1080 140 4.0ETH-15 230 1.5 45 1580 140 6.0

ETH Terrace Heater – smart modern design

The IP44 rated ETH safe to be mounted outdoors

Brackets supplied with each heater for easy installation

and angle adjustment

Page 49: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 49

RADIANT HEATERSHB Shortwave Workshop and Smoking Area Heater

TS-3 Energy - saving timer with

tamperproof adjustment of time

delay

• Alowcostmeansofprovidinginstantdirect heat

• Ideallysuitedtoheatingaworkbench• Veryeconomicasnopre-heatingis

required

Typical Applications• Smokingarea• Workshops• Packingbench

Features• IP44 rated for outdoor use• Highqualityhalogenlampwith7000hoursaverageoperatinglife• Goldlampwithsoftpinkglow• Wallmountingbracketproviding‘upanddown’angleadjustment(notsuitableforsuspension)• Built-insafetyguard• Pre-wiredpowercableAttherecommendedmountingheightof2.2m,theHW-15willheatanareaapproximately3mwidex2.6mdeep.

Shortwave Workshop Heater - SpecificationsModel Volts kW Dimensions (mm) Weight (kg)

H W DHB-1500 230 1.5 140 400 85 1.5RL-15GH ReplacementGoldLamp1.5kW

Controlling the HB-1500Forimprovedeconomy,anHB-1500canbecontrolledbymeansofatimedelayswitchormovementsensor.

Push Button Timer TheTS-3pushbuttontimerisawallmounteddevicewitha16Aswitchingcapacity.Whenthebuttonispushedtheheaterwillbeenergisedforapre-programmedperiodbetween2minutesand2hours.Oncethisperiodhaselapsedtheheaterwillbeautomaticallyswitchedoff.

Movement SensorTheWH-402movementsensorhasa16Aswitchingcapacityandcanbeprogrammedfortimeperiodsbetween5secondsand18minutes.Shouldmovementnotbedetectedwithinthisperiod,theheaterwillbeautomaticallyswitchedoff.

WH-402 Energy saving device ensuring that heating is switched off when

an area is unoccupied

Optional Remote Control DevicesModel Description Full Details on PageTS-3 PushButtonTimer16A 68WH-402 MovementSensor16A 69

HB-1500 Providing instant, direct heat to a technician at BN Thermic's

Crawley HQ

HB-1500 can be used indoors or outdoors

Page 50: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143250

RADI

ANT

HEAT

ERS

Controlling HN HeatersAsHNshortwaveinfraredhalogenheatersare100%effectivetheinstanttheyareswitchedon,werecommendacontrolsystemthatwillde-energiseaheaterwhenheatingisnotrequired.ThiscanbeachievedbymeansofaPushButtonTimeroraMovementDetector.

Push Button Timer – TS-3 pre-programmed time delayTheBNThermicTS-3isacompact,surfacemount,weatherproofdeviceconformingtoIP66.Asimplepushbuttonwillenergiseaheaterorheatersforapre-programmedperiodbetween2minutesand2hours.Oncethisperiodhaselapsedtheheatingwillbeautomaticallyswitchedoffuntilthebuttonispushedagain.Thedeviceisvandalresistantandtamperproofmeaningonlyauthorisedpersonnelcanadjustthetimesettings.ForfulldetailsoftheTS-3seepage68TheTS-3hasaswitchingcapacityof16A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

Push Button Timer – TS-4 user selectable time delayTheBNThermicTS-4isdesignedforinstallationintoastandardsingle-gangbackbox.Asimplepushbuttonprovides15minute/30minute/1hour/2hoursettings.Oncetheselectedperiodhaselapsedtheheatingwillbeautomaticallyswitchedoffuntilthebuttonispushedagain.Thetimesettingcanbechangedatanypointduringthecycleandthetimeralsoprovidesameansofswitchingtheheatingoff.ForfulldetailsoftheTS-4seepage68.TheTS-4hasaswitchingcapacityof13A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

HN Series Shortwave Infrared Halogen Heaters• Providing instant comfort heat in a variety of commercial and

industrial buildings. • Especially suited to irregularly used buildings where

conventional space heating is impractical.• Ideally suited to spot heating a defined area within an otherwise

unheated space• Low running costs by selecting from a range of control options

Typical Applications• Communityhalls• Churches• Workshops• Packingareas• Squashcourts

Features Common to all Models• Aluminiumconstructionwithcloselyspacedsafetygrille• Highqualityhalogenlampwith7000hoursaverageoperatinglife• Halogenlampiseasilyreplaceable• Highqualityivorypaintfinish• Wallmountingbracketproviding‘upanddown’and‘sidetoside’

angleadjustment• Optionalsuspensionkit• Goldlampwithsoftpinkglow

HN-1500G 1.5kW Shortwave Heater

HN-3000G 3kW Shortwave Heater

HN-4500G 4.5kW Shortwave Heater

TS-3 Energy - saving timer with

tamperproof adjustment of

time delay

TS-4 Energy - saving timer

allowing easy adjustment of

time delay

Page 51: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 51

RADIANT HEATERSMovement SensorTheBNThermicWH-402isacompact,surfacemount,weatherproofdeviceconformingtoIP55.TheWH-402willdetectmovementinanareaupto12mfromitsmountingpositionina180°arc.Bothdistanceandangleofdetectioncanbereducedifrequired.Oncemovementhasbeendetected,theheatingwillbeswitchedon.Ifnofurthermovementisdetectedwithinapre-programmedtimeperiod(5secondsto18minutes)theheatingwillbeautomaticallyswitchedoff.ForfulldetailsoftheWH-402seepage69.TheWH-402hasaswitchingcapacityof16A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

DimmerInspecificapplicationstheremaybeaneedtoadjusttheintensityoftheheatoutputfromaShortwaveInfraredHalogenHeater.TheBNThermicVR-1providesadjustmentbetween0%and100%ofheateroutput.Italsohasadefinite‘click’tooffallowingittobeusedasanon/offswitch.ForfulldetailsoftheVR-1seepage69.TheVR-1hasaswitchingcapacityof13A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.ForlargerloadsmorethanoneVR-1dimmerwillberequired.

Heat RequirementsUse Table 1todeterminethetotalkWoutputrequired.TheW/m2applicabletothetypeofactivityandthenatureofthebuildingshouldbemultipliedbythetotalareainm2.The‘spotheating’figureshouldbeusedwhenheatingasectionofanotherwiseunheatedbuilding.Theoutput,positionandmountingheightoftheheaterscanbedeterminedusingTable 2.Wesuggestthattheareascoveredbyindividualheatersareallowedtooverlapby10%to15%toensureevencoverage.

Table 1W/m� required

HeavyWork

Light Work

Spot Heating

HighlyInsulated

150 200 250

Insulated 175 225 250

Un-Insulated 200 250 275

Light Cladding 250 300 300

Badlyinsulated/damp

300 300 300

Table 2Wall Mounted Area Covered

(m�)Overhead Mounted (m) Area Covered

(m�)H X Y Z H X Y

HN-1500G or HN-2000G

2.5 3.2 2.6 6.0 11.9 3.0 3.0 2.0 6.0

3.0 3.4 3.6 6.7 18.2 3.5 3.3 2.3 7.6

HN-3000G3.0 3.7 3.6 7.0 19.2 3.5 3.3 2.6 8.6

3.5 4.0 4.2 7.9 25.0 4.0 5.0 3.1 15.5

HN-4500G or HN-6000G

3.5 4.0 4.2 8.1 25.4 4.0 5.0 3.4 17.0

4.0 4.3 4.5 8.4 28.6 5.0 5.3 3.7 19.6

Spot HeatingAsanadditionalguidetospotheating,wewouldalsorecommendheatingfromtwodirections,tocovertheareafromoppositesides.Thiswillensureanoverallfeelingofcomfortandwarmth.Aheatloadingof250-300W/m2canbeconsideredasaguideforthistypeofarea.

H

XY

H

Y

Z

X

Ceiling MountedWall Mounted

WH-402 Energy saving device ensuring that heating is switched off when

an area is unoccupied

VR-1 Dimmer switch for fine adjustment of

heater output

H

Page 52: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143252

RADI

ANT

HEAT

ERS

Heater Selection

HN Series Shortwave Infrared Halogen Heaters - SpecificationsModel Volts kW Dimensions (mm) Weight

(kg)H W DHN-1500G 230 1.5 275 430 140 3.8HN-2000G 230 2.0 275 430 140 3.8HN-3000G 230 3.0 430 430 140 5.5HN-4500G 230/400 4.5 590 430 140 6.5HN-6000G 230/400 6.0 590 430 140 6.5RL15GF 230 1.5 ReplacementGoldLampfor1.5,3&4.5kWheatersRL20GF 230 2.0 ReplacementGoldLampfor2&6kWheatersHSK SuspensionKit(chainnotsupplied)

Optional Remote Mounted Control DevicesModel Description Full Details on PageWH-402 Movementsensor(16A) 69TS-3 Pushbuttontimer(16A) 68TS-4 Pushbuttontimer-userselectabletimedelay(13A) 68VR-1 Dimmer(13A) 69

HN Continued

HN-Shortwave Infrared Halogen Heater with long

life gold lamps

HN-3000G shortwave heaters providing instant

economical heating in St Stephen’s Church Barnet

Page 53: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 53

RADIANT HEATERSRL Replacement Infrared LampsArangeofshortwavequartzhalogenheatlampstosuitalmostallavailableheatersfromavarietyofmanufacturers.

Lamps with flexible leads and SK15 capsUsedinavarietyofopenfrontedcommercialandindustrialheaters. Averagelamplife7000hours

Model kW Voltage Colour Lamp length(mm)

Lead length(mm)

Terminal

RL10RF 1 230 Ruby 346 230 ForkRL10GF 1 230 Gold 353 230 ForkRL15RF 1.5 230 Ruby 346 230 ForkRL15GF 1.5 230 Gold 353 230 ForkRL15RF/1 1.5 120 Ruby 346 230 ForkRL15RP 1.5 230 Ruby 346 440 Push FitRL15GP 1.5 230 Gold 346 440 Push FitRL20RF 2 230 Ruby 346 230 ForkRL20GF 2 230 Gold 353 230 Fork

Weatherproof (IP55) lamps with flexible leadsGenerallyusedinopenfrontedpatioheaters.Averagelamplife7000hours

Model kW Voltage Colour Lamp length(mm)

Lead length(mm)

Terminal

RL15CW 1.5 230 Clear 440 375 Plain FerruleRL15GW 1.5 230 Gold 440 375 Plain FerruleRL15GW/3 1.5 230 Gold 440 200&600 Plain FerruleRL15GW/4 1.5 230 Gold 440 430&905 Plain FerruleRL20GW 2 230 Gold 440 375 Plain Ferrule

Lamps with R7s capsGenerallyusedinglassfrontedpatioheaters.Thislampisusedwithspringloadedfittings.Averagelamplife3000hoursinglassfrontedheaters.

Model kW Voltage Colour Lamp length (mm)RL13GS 1.3 230 Gold 254

Lamp length

Lead length

Lamp length

Colour options

Ruby

Gold

Colour options

Clear

Gold

Lamp length

Lead length

Fork terminal

Push fit terminal

Page 54: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143254

RADI

ANT

HEAT

ERS

54

CH Ceramic Heaters• Providing virtually instant comfort heat in a

variety of commercial and industrial buildings. • Especially suited to irregularly used buildings

where conventional space heating is impractical.• Avoids the light output associated with shortwave

infrared heaters• Ideally suited to spot heating a defined area

within an otherwise unheated space• Low running costs by selecting from a range of

control options

Typical ApplicationsPleasenoteceramicheatersarebestsuitedtobuildingswithrelativelylowceilings• Communityhalls• Workshops• Kennels• Zoos

Features Common to all Models• Aluminiumconstructionwithsafetygrille• Longlifeceramicheatemitters• Highqualityivorypaintfinish• Wallmountingbracketandproviding‘upand

down’and‘sidetoside’angleadjustment

Controlling CH HeatersAsCHceramicheatersare100%effectivewithinfourminutesofbeingswitchedon,werecommendacontrolsystemthatwillde-energiseaheaterwhenheatingisnotrequired.ThiscanbeachievedbymeansofaPushButtonTimeroraMovementDetector.

Push Button Timer – TS-3 pre-programmed time delayTheBNThermicTS-3isacompact,surfacemount,weatherproofdeviceconformingtoIP66.Asimplepushbuttonwillenergiseaheaterorheatersforapre-programmedperiodbetween2minutesand2hours.Oncethisperiodhaselapsedtheheatingwillbeautomaticallyswitchedoffuntilthebuttonispushedagain.Thedeviceisvandalresistantandtamperproofmeaningonlyauthorisedpersonnelcanadjustthetimesettings.ForfulldetailsoftheTS-3seepage68.TheTS-3hasaswitchingcapacityof16A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

Push Button Timer – TS-4 user selectable time delayTheBNThermicTS-4isdesignedforinstallationintoastandardsingle-gangbackbox.Asimplepushbuttonprovides15minute/30minute/1hour/2hoursettings.Oncetheselectedperiodhaselapsedtheheatingwillbeautomaticallyswitchedoffuntilthebuttonispushedagain.Thetimesettingcanbechangedatanypointduringthecycleandthetimeralsoprovidesameansofswitchingtheheatingoff.ForfulldetailsoftheTS-4seepage68.TheTS-4hasaswitchingcapacityof13A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

RADI

ANT

HEAT

ERS

TS-3 Energy - saving device

with time delay selected by authorised

personnel

TS-4 Energy - saving device allowing time

delay selected and altered easily

CH-3000 3kW Ceramic Heater providing directional radiant heat without light output

CH-1500 1.5kW Ceramic Heater fully effective within a few minutes

Page 55: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 55

RADIANT HEATERSMovement SensorTheBNThermicWH-402isacompact,surfacemount,weatherproofdeviceconformingtoIP55.TheWH-402willdetectmovementinanareaupto12mfromitsmountingpositionina180°arc.Bothdistanceandangleofdetectioncanbereducedifrequired.Oncemovementhasbeendetected,theheatingwillbeswitchedon.Ifnofurthermovementisdetectedwithinapre-programmedtimeperiod(5secondsto18minutes)theheatingwillbeautomaticallyswitchedoff.ForfulldetailsoftheWH-402seepage69.TheWH-402hasaswitchingcapacityof16A.Itcanthereforedirectlyswitchacombinedloadofupto3kW.Largerloadsor3-phaseloadscanbeswitchedviaasuitablyratedcontactor(seepage64).

CH Ceramic Heaters - SpecificationsModel Volts kW Dimensions (mm) Weight (kg)

H W DCH-1500 230 1.5 190 405 72 1.8CH-3000 230 3.0 345 405 72 2.8

Optional Remote Mounted Control DevicesModel Description Full Details on PageWH-402 Movementsensor(16A) 69TS-3 Pushbuttontimer(16A) 68TS-4 Pushbuttontimer-userselectabletimedelay(13A) 68

Bracket providing ‘up and down’ adjustment

CH-1500 Ceramic Heaters providing an economic means of

heating a community hall

Bracket fitted with extension arm providing

‘up and down’ and ‘side to side’ adjustment

WH-402 Energy saving device ensuring that heating is switched off when

an area is unoccupied

Page 56: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143256

RADI

ANT

HEAT

ERS

RP Radiant Ceiling Panels• Providing a sophisticated noise and draught free means of heating

commercial premises• Low running costs• Extra safety as personnel have no access to heaters• Ceiling mounting allows flexible use of floor and

wall space and does not interfere with activities

Typical Applications• CareHomes• Trade Counters• Offices• MeetingRoomsTheinstalledloadmustexceedtheheatlossfromtheentirearea.RPblackheatradiantcassettesarenotideallysuitedto‘spotheating’applicationsalthoughtheycanprovidealocalisedtemperatureboostwithinalargerspace,perhapsoveraworkstation.

Features Common to all Models• Specificallydesignedforquickandeasyinstallationinto

suspending ceilings• Bracketsuppliedforeasymountingontoaconventional

ceiling• Attractivewhitefinish• FullyenclosedsteelcaseconformingtoIP44• Integralinsulationlayerensuresthatradiantenergyisdirectedintotheroom• Suitableformountingheightsupto4m

Selection and InstallationThetotalloadoftheselectedRPCeilingPanelsshouldexceedtheheatlossfromthebuildingincoldconditions.Theheatersshouldbepositionedsothatthespacebetweentheheatersisnogreaterthanthedistancebetweentheheatersandthefloor.RPCeilingPanelsshouldbeseenasaneconomicalternativetoconventionalspaceheatingsystems,theyarenotideallysuitedto‘spotheating’applicationsalthough theycanprovide a localised temperatureboostwithinalargerspaceperhapsoveraworkstation.

RP-03 provides an almost invisible source of gentle

radiant heat

RP-06 specifically sized for easy installation in a 1200 x 600 ceiling grid but supplied with bracket for

mounting onto a conventional ceiling if required

Typical arrangement of RP-03 ceiling panels in a 600 x 600 ceiling grid

5.4m

7.2m

Page 57: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 57

RADIANT HEATERS

Energy SavingRPCeilingPanelsareamoreeconomicmeansofheatingcommercialpremisesthanconventionalheatingsystems.• Thegentleradianteffectmeansthatthe‘experiencedtemperature’canbeupto4°Cwarmerthantheactualair

temperature.Thismeansthatthethermostatcanbesetupto4°Clower.• Thetemperaturegradientisnegligible.Typicallyairtemperaturewillincreaseby0.3°Cpermetreabovefloor

level.Thisfigurecomparestoatypical2.5°Cpermetrewhenusingfanheaters.

Controlling RP Radiant Ceiling PanelsBNThermic’sHardCaserangeoftamperproofThermostatsisideallysuitedtocontrollingaradiantheatingsystem.Itstamperproofdesignenhancesthesystem’seconomybyensuringthatthatonlyauthorisedpersonnelcanadjustthetemperaturesetting.AHardCaseThermostatcandirectlycontrolaloadofupto3kW.Largerloadsand3phaseloadscanbecontrolledviaasuitablyratedcontactor(seepage64).

RP Radiant Ceiling Panels - SpecificationsModel Volts kW Dimensions (mm) Weight (kg)

H W DRP-03 230 0.3 25 595 595 5RP-06 230 0.6 25 1195 595 10

Remote ThermostatModel Description Full Details on PageHC-T2 TamperproofThermostat16A 62HC-D TamperproofToolforHC-T2 62

ThistableonlyshowsthebasicHC-T2HardCaseThermostat.HoweveritispossiblethatanalternativemodelfromtheHardCaseRangemaybemoresuitableforanygiveninstallation.Pleaseseepage62forfulldetailsoftheHardCaserange.

Reverse side RP-03 showing mounting bracketThe RP-03 is specifically sized for easy installation in a

600 x 600 ceiling grid but supplied with bracket for mounting onto a conventional ceiling if required

HC-D Tamperproof Tool for HC-T2Ensuring that only authorised personnel can

adjust temperature settingsHC-T2 Energy Saving Tamperproof

Electronic Control Device

Page 58: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143258

RADI

ANT

HEAT

ERS

ESP Radiant Cassettes• Providing an extremely economic means

of heating large commercial spaces• Exceptional reliability – backed by 5 year

warranty• Attractive unobtrusive design well suited

to modern facilities• High mounting positions allows flexible

use of floor and wall space and does not interfere with activities

Typical Applications• Sports Halls• SquashCourts• Showrooms• CommunityHalls• Food HallsTheinstalledloadmustexceedtheheatlossfromtheentirearea.ESPblackheatradiantcassettesarenotideallysuitedto‘spotheating’applications.

Features Common to all Models• FIVEYEARWARRANTY• Nodraughts,noiseorlightoutput• Robuststeelcasewithattractivewhiteepoxyfinish• Speciallytreatedaluminiumheatemitter• Bracketsforceilingmountingandfourfixingpointstofacilitatesuspension

Optional Adjustable Brackets ESP-Badjustablebracketscanbeusedforbothwallandceilingmounting.Thebracketsaredesignedtoallowtheangleoftheheatertobeeasilyadjusted.

Selection and InstallationThe total load of the selected ESP cassettesshouldexceedtheheatlossfromthebuildingincoldconditions.Theheatersshouldbeceilingmountedorsuspended at high level ensuring that the spacebetweentheheatersisnogreaterthanthedistancebetweentheheatersandthefloor.BlackHeatRadiantCassettesshouldbeseenasanenergysavingalternativetoconventionalspaceheatingsystems,theyarenotideallysuitedto‘spotheating’applications.

20m

10m

2.58m

2.32m

0.35m

0.35m

2.32m

4.64m

5.16m 5.16m1.5m 1.5m 1.5m 2.58m

Typical ESP System Layout

Energy SavingESPRadiantCassettesareourmosteconomicheatersforbuildingswithhighroofsforthefollowingreasons:• Thegentleradianteffectmeansthatthe‘experienced

temperature’canbeupto4°Cwarmerthantheactualairtemperature.Thismeansthatthethermostatcanbesetupto4°Clower.

• Thetemperaturegradientisnegligible.Typicallyairtemperaturewillincreaseby0.3°Cpermetreabovefloorlevel.Thisfigurecomparestoatypical2.5°Cpermetrewhenusingfanheaters.

Energy Saving with ESP Radiant Cassettes

Height above floor level Approx Air Temp6m

5m

4m

3m

2m

1m

18.5°C

18.2°C

17.9°C

17.6°C

17.3°C

17°C

Height above floor level Approx Air Temp6m

5m

4m

3m

2m

1m

32.5°C

30°C

27.5°C

25°C

22.5°C

20°C

Heating a building using ESP Radiant Cassettes

Heating a large building using fan heaters

ESP-B Optional Adjustable BracketsCan be used for both wall and

ceiling mounting.

The ESP range providing an economic

means of heating large areas

5

New compact model

Page 59: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 59

RADIANT HEATERSControlling ESP Radiant CassettesTherecommendedmeansofcontrollingESPBlackHeatRadiantCassettesistoselectoneoffourcontrolpackages

Comfort control package

Programmable package

Programmable package with set-back

Flexible Package

AllcontrolpackagesarebasedonBNThermic’srangeofHardCasetamperproofandvandalresistantThermostats.HardCase’stamperproofdesignensuresthatonlyauthorisedpersonnelcanadjustthetemperaturesetting.

Comfort Control PackageThecomfortpackageutilisestheHardCaseHC-T2TamperproofThermostatwhichshouldbewallmountedatapproximately1.5mabovefloorlevel.Thethermostatwillswitchtheheatersviaasuitablyratedcontactor.

Control ComponentsHC-T2TamperproofThermostatSuitablyRatedContactor

Programmable PackageTheprogrammablepackageutilisestheHardCaseHC-T2TamperproofThermostatwhichshouldbewallmountedatapproximately1.5mabovefloorlevel.TheThermostatwillswitchtheheatersviaasuitablyratedcontactor.A24hour/7dayprogrammabletimer(TIM-D1)willensurethattheheatingsystemisnotenergisedwhilethebuildingisunoccupied(typicallyatnightandatweekends).Theprogrammabletimerhasabuilt-inrun-downclockthatistriggeredbyaremotemounted‘boostbutton’.Thisfeaturewillprovideatemporarytemperatureboostforapre-determinedlengthoftimeduringaperiodwhenthesystemwouldnormallybe‘off’.Theboostcommandcanbecancelledbydepressingthe‘boostbutton’for3seconds.Control ComponentsHC-T2TamperproofThermostatTIM-D1ProgrammableTimerTIM-E1TimerEnclosureTIM-B1 PushButtonfortemporaryboostSuitablyRatedContactor

TIM-B1Push Button

For temporary boost

TIM-D1Programmable

timer

HC-T2Tamperproof Electronic

Control Device

CONContactor selected to

suit heating load

ESPGroup of black heat

radiant cassettes

HC-T2Tamperproof Electronic

Control Device

CONContactor selected to

suit heating load

ESPGroup of black heat

radiant cassettes

Page 60: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143260

RADI

ANT

HEAT

ERS

Programmable Package with Set-BackTheprogrammablepackagewithset-backutilisestheHardCaseHC-ST2TamperproofThermostatwhichshouldbewallmountedatapproximately1.5mabovefloorlevel.TheThermostatwillswitchtheheatersviaasuitablyratedcontactor.TheHC-ST2hastwosettings:high(comfort)andlow(set-back).A24hour/7dayprogrammabletimer(TIM-D1)willensurethattheheatingsystemoperatesatitslow(set-back)settingwhilethebuildingisunoccupied(typicallyatnightandatweekends).Theprogrammabletimerhasabuilt-inrun-downclockthatistriggeredbyaremotemounted‘boostbutton’.Thisfeaturewillprovideatemporarytemperatureboostforapre-determinedlengthoftimeduringaperiodwhenthesystemwouldnormallybeinset-backmode.Theboostcommandcanbecancelledbydepressingthe‘boostbutton’for3seconds.Control ComponentsHC-ST2TamperproofThermostatTIM-D1ProgrammableTimerTIM-E1TimerEnclosureTIM-B1 PushButtonfortemporaryboostSuitablyRatedContactor

Flexible PackageTheflexiblecontrolpackageutilisesaHardCaseHC-ST2ThermostatswitchingagroupofBlackHeatRadiantCassettesviaasuitablyratedcontactor.TheHC-ST2hastwosettings:high(comfort)andlow(set-back).Thedefaultsettingislow(set-back).The HC-ST2incorporatesasimplepushbuttonwhichchangestheset-pointfromlow(set-back)tohigh(comfort)forapre-programmedperiodoftime(1/2,1,2or4hours).OncethisperiodoftimehaselapsedtheThermostatwillautomaticallyreverttoitslow(set-back)setting.

Control ComponentsHC-ST2TamperproofThermostatSuitablyRatedContactor

ESP Continued

HC-ST2Tamperproof Electronic

Control Devicewith high-low settingsand run-down timer

CONContactor selected to

suit heating load

ESPGroup of black heat

radiant cassettes

TIM B1Push Button

For temporary boost

TIM D1Programmable

timer

HC-ST2Tamperproof Electronic

Control Devicewith high-low settings

CONContactor selected to

suit heating load

ESPGroup of black heat

radiant cassettes

ESP heaters providing cost effective heating in a showroom in Maidstone

Page 61: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 61

RADIANT HEATERSESP2 Radiant cassettes - SpecificationsModel Volts kW Dimensions (mm) Mounting

Height (m)Weight

(kg)H W D

ESP2-09 230 0.9 60 1550 150 2.8to8 5.8ESP2-12 230 1.2 60 1550 150 2.8to8 5.8ESP2-18 230 1.8 60 1550 250 3.0to8 9.9ESP2-24 230 2.4 60 1550 250 3.0to8 9.9ESP2-30 230or400/3N 3.0 60 1550 350 3.0to8 13.9ESP2-36 230or400/3N 3.6 60 1550 350 3.0to8 13.9ESP2C-06 Compact 230 0.6 60 650 230 2.8to8 5.5ESP2C-08 Compact 230 0.85 60 850 230 2.8to8 7.5ESP2-B Optionalwallbrackets(pair)suitableforallESP2models

Tamperproof ThermostatsModel DescriptionHC-T2 TamperproofThermostatHC-ST2 TamperproofThermostatwithSet-BackHC-D TamperproofToolforHardCase(HC)range

AllHardCasemodelshavetheoptionofaremotesensor(seepages62-63)

TimerModel DescriptionTIM-D1 TimerTIM-E1 TerminalenclosureforTIM-D1timerTIM-B1 PushButtonforusewithTIM-D1(providestemporaryboost)

Contactors (230V coil)Model Phases Amperage/

PhaseMax kW/

PhaseEnclosure Type

CON-20 1 20 4.4 ACON-40 1 40 7.8 BCON-63 1 63 12 BCON-30-3 3 30 6 CCON-50-3 3 50 10.8 DCON-80-3 3 80 16 DCON-110-3 3 110 23 DENCL-A ContactorEnclosureTypeAENCL-B ContactorEnclosureTypeBENCL-C ContactorEnclosureTypeCENCL-D ContactorEnclosureTypeD

TIM-B1 Push Button providing temporary temperature boost

when used with a TIM-D1 timer

TIM-D1 programmable timer fitted into TIM-E1 enclosure

with memory card and optional PIN protection

Contactor mounted in a suitable enclosure allowing a single thermostat to switch a

group of ESP Radiant Cassettes

HC-T2 Energy Saving Tamperproof Electronic

Control Device

HC-D Tamperproof Tool for HC-T2Ensuring that only authorised

personnel can adjust temperature settings

HC-ST2 Tamperproof Electronic Control Device with two

adjustable set-points

Page 62: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143262

CONT

ROLS

HC-S2 Remote SensorOptionalremotemountedsensorforusewithHC-T2andHC-ST2tamperproofThermostats.Whentheprovidedgasketisfitted,theunitwillconformtoIP55(protectedagainstwatersprayedfromalldirections).Dimensions:74x51x28mm

HC-D Special Tool for Removing Tamperproof ScrewsThekeytotheHardCaseenergysavingpotentialistheHC-D.Withoutthisdeviceitisimpossibletoadjusttemperaturesettings.Thisensuresthatchangesareonlymadebyauthorisedpersonnelandpreventscasualorwillfuladjustmentsbeingmade.

CONTROLS Hard Case ThermostatsHC-T2 Standard Thermostat

ApplicationComfortheatingcontrol or frost protection

Features specific to HC-T2Adjustable range (comfort): 12to25⁰CAdjustable range (frost protection): 0to12⁰CSelectionbetweenrangesbymeansofswitch locatedundertamperprooflidOutput switch rating: 16AOutput switch: ChangeoverAdjustable differential: 0.25to5⁰CPower Supply: 230VDimensions: 120x95x56.5mmWeight: 0.33kg

HC-T2 External View Note Tamperproof screws preventing unauthorised

personnel from adjusting temperature settings

HC-T2 Internal View Note switch allowing either ‘comfort’ or ‘frost

protection’ to be selected

Energy Saving Tamperproof Thermostats• Energy saving control devices because only

authorised personnel can adjust temperature settings

• Vandal resistant design suitable for public areas

• Highly accurate electronic temperature control ensures lowest possible heating costs

• Top quality products backed by 5 year warranty

Typical Applications• ControllingBNThermicheatingsystemssuch

as OUH Industrial Unit Heaters and ESP Radiant Cassettes

• Accuratetemperaturecontrolinshops,warehouses,schools,sportshallsetc

• Frequentlyusedasanintegralcomponentinaprogrammableheatingsystem

Features Common to both Models• Tamperproofdesignrequiresaspecialtool

(HC-D)toadjusttemperaturesettings• Electroniccontrolaccuratetowithin+/-0.5°C• Superrobustvandalresistantdie-cast

aluminiumenclosure• Integralblacksensorideallysuitedforcontrol

ofradiantheatingsystems• SuitableforusewitharemoteHC-S2Sensor

Page 63: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 63

CONTROLS

HC-ST2 Thermostat with Set-Back

ApplicationProvides frost protectionasadefaultwithacomfortsettingforprogrammableperiods

Operation

Operation Mode 1 – Using Integral Run-Down TimerIdealforirregularlyusedfacilitiesTheHC-ST2hastwosettings:high(comfort)andlow(set-back).Thedefaultsettingislow(set-back).TheHC-ST2incorporatesasimplepushbuttonwhichchangestheset-pointfromlow(set-back)tohigh(comfort)forapre-programmedperiodoftime(½hourto7½hoursin½hourincrements).Oncethisperiodoftimehaselapsedthedevicewillautomaticallyreverttoitslow(set-back)setting.Thismethodofcontrolisidealforirregularlyusedfacilitiessuchascommunityhallswheretheset-backsettingwillprovidefrostprotectionwhilethehallisunoccupied.

Operation Mode 2 – Using Remote Programmable TimerIdealforfacilitieswitharegularpatternofuse(withaprovisionforoccasionalcomfortheatingoutsidenormalhours)TheHC-ST2hastwosettings:high(comfort)andlow(set-back)andrequiresaremotesignaltoswitchbetweenoneandtheother.Typicallythissignalisprovidedbyaremotemounted24hour/7dayprogrammabletimer(TIM-D1)thatwillensurethattheheatingsystemoperatesatitslow(set-back)setting,providingfrostprotectionwhileabuildingisunoccupied(typicallyatnightandatweekends).Theprogrammabletimerhasabuilt-inrun-downclock

thatistriggeredbyaremotemounted‘boostbutton’(TIM-B1).Thisfeaturewillprovideatemporarytemperatureboostforapre-determinedlengthoftimeduringaperiodwhenthesystemwouldnormallybeinset-backmode.Theboostcommandcanbecancelledbydepressingthe‘boostbutton’for3seconds.Thissystemisidealforpremisesthathavearegularpatternofusebutmayoccasionallybeusedoutsidenormalhours.Seepage64fordetailsoftimerandboostbutton.

Features specific to HC-ST2Adjustable range (comfort): 12to25⁰C

Adjustable set-back: Upto20⁰Cbelowhigh temperaturesetting

Led indicator: blue(set-back)orred (comfort)

Output switch rating: 16A

Output switch: Changeover

Adjustable differential: 0.25to5⁰C

Power Supply: 230V

Dimensions: 120x95x56.5mm

Weight: 0.33kg

HC-ST2 Internal View Note adjustment knobs for both comfort

and set-back settings

HC-ST2 External View Note push button used to activate run-down timer

TIM-B1Push Button

providing temporary boostto comfort

TIM-D17-day Programmable

timer. Changes controlfrom set-back to comfort

HC-ST2Tamperproof thermostat

with two settings:HIGH (comfort) and

LOW (set-back)

HC-ST2 Used with a programmable timer

HC Hard Case - PricesModel DescriptionHC-T2 Standard Electronic Control DeviceHC-ST2 Set-BackElectronicControlDevicewith

Run-DownTimerHC-S2 StandardRemoteSensorHC-D SpecialToolforRemovingTamperproof

Screws

Page 64: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143264

CONT

ROLS

CONTROLS TimersTIM-D1 24 Hour/7 Day Programmable Timer

ApplicationIdealforusewithBNThermic’srangeofHardCaseTamperproofThermostatstoprovideeconomicandyetadaptableheatingcontrolpackages

Features• Dailyandweeklyprogrammes• DisplayIllumination(canbeswitchedoff)• Memorycardsuppliedasstandard(canbeusedforprogrammeoverride)• PINprotection(optional)• Datecontrolledholidayprogramme• Automaticsummer/wintertimechanges• Integralcount-downtimerwithruntimeupto23hours59minutesandactivatedbyTIM-B1

remotepushbutton.WhenusedwithaHardCaseThermostat,theTIM-B1PushButtonwillprovideaboosttocomforttemperatureduringaperiodwhenthesystemisin‘off’or‘set-back’mode.Oncethepre-programmedruntimehaselapsed,thesystemwillreverttotheprogramme.TheboostsignalcanbecancelledbydepressingtheTIM-B1PushButtonfor3seconds.

• Dimensions:86x35x66mm• OptionalterminalenclosureTIM-E1

TIM-B1 Push Button

TIM-D1 and Enclosure TIM-E1

CONTROLS ContactorsContactorsallowathermostatorsimilarswitchingdevicetoswitchlarge single phase or three phase loads.(230Vcoil–resistiveloadsonly)

CON-20 mounted in ENCL-A enclosure

ENCL-C

CON-50-3 mounted in ENCL-C enclosure on DIN rail

CON-50-3

Contactors - SpecificationsModel Phases Amperage/Phase Max kW/Phase Enclosure TypeCON-20 1 20 4.4 ACON-40 1 40 7.8 BCON-63 1 63 12 BCON-30-3 3 30 6 CCON-50-3 3 50 10.8 DCON-80-3 3 80 16 DCON-110-3 3 110 23 DENCL-A ContactorEnclosureTypeAENCL-B ContactorEnclosureTypeBENCL-C ContactorEnclosureTypeCENCL-D ContactorEnclosureTypeD

TIMERS Model DescriptionTIM-D1 ProgrammableTimerTIM-E1 TerminalenclosureforTIM-D1timerTIM-B1 PushButtonforusewithTIM-D1(providestemporaryboost)

Page 65: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 65

CONTROLS

RST-IN Thermostat for Comfort Heating Applications

ApplicationTheRST-INisasimplewall-mountedthermostatsuitableforcontrollingavarietyofspaceheaters

SpecificationAdjustable Range +5°Cto+30°CMounting SurfaceSwitching Capacity 10A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)Voltage Supply 230VContacts Singlepole,changeoverDimensions 74x74x23mmIngress protection: IP30Special Features Integralheatanticipatorimprovescontrolaccuracy.Adjustable rangecanbelimitedorlocked.

RST-EX Thermostat suitable for Damp Conditions

ApplicationTheRST-EXhasahighIPratingmakingitsuitableforapplicationssuchasplantroomsandwatertreatmentworks

SpecificationAdjustable Range +5°Cto+35°CMounting SurfaceSwitching Capacity 15A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)Voltage Supply NoneRequiredContacts Singlepole,changeoverDimensions 105x105x60mmIngress protection: IP54

FST-IN Frost Thermostat

ApplicationTheFST-INwillprovideaccuratecontrolatlowtemperaturesandisidealforusewithpipefreezeprotectioncables

SpecificationAdjustable Range -20°Cto+30°CMounting SurfaceSwitching Capacity 10A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)Voltage Supply 230VContacts Singlepole,changeoverDimensions 74x74x23mmIngress protection: IP30Special Features Integralheatanticipatorimprovescontrolaccuracy. Adjustablerangecanbelimitedorlocked.

CONTROLS ThermostatsBNThermicoffersarangeofthermostatstomeettherequirementsofavarietyofcommercialandindustrialheatingapplications.FortamperproofandvandalresistantdevicespleaseseeourHardCaserangeonpage62

Page 66: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143266

CONT

ROLS

FST-EX Frost Thermostat for Outdoor Use

ApplicationTheFST-EXwillprovideaccuratecontrolatlowtemperaturesandisidealforusewithpipefreezeprotectioncables.AhighIPratingmeansthatthisdeviceissuitableforoutdooruse.

SpecificationAdjustable Range -20°Cto+30°CMounting SurfaceSwitching Capacity 10A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)Voltage Supply 230VContacts Singlepole,changeoverDimensions 125x125x75mmIngress protection: IP65Special Features Integralheatanticipatorimprovescontrolaccuracy.Adjustable rangecanbelimitedorlocked.Covermustberemovedtoallow set-pointadjustment

PROSTAT-7 Programmable Thermostat

ApplicationBycontrollingbothairtemperatureandthehoursofoperation,thePROSTAT-7ensuresmaximumeconomyinawidevarietyofcommercialapplications.Asimpleoverridefacilityprovidesaquckboosttocomfortlevelswhenthethermostatwouldnormallybeinset-backmode.

SpecificationAdjustable Range +5°Cto+30°CMounting SurfaceSwitching Capacity 6A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)Voltage Supply 3xAAbatteries(supplied)Contacts Singlepole,changeoverDimensions 142x71x30mmIngress protection: IP30Special Features Batterylifeinexcessof2years Upto6programmableeventsperday Temporarytemperatureoverrideuntilnextpresetperiod Temperaturelock–permanenttemperatureoverrideuntilreset.

GP-T Electronic Thermostat for Gutter and Downpipe Heating Systems

ApplicationTheproblemsassociatedwithsnowandiceoccurwhentheambienttemperatureisbetween+5⁰Cand-5⁰C.Toensuremaximumeconomy,theGP-Thastwoset-points.Inthiswaythesystemwillbeswitchedoffwhenthetemperatureiseithertoohighortoolowforproblemstoarise.TheGP-Tshouldbemountedexternallyinashelteredlocation.

SpecificationAdjustable Range: -10⁰Cto+30⁰CMounting: SurfaceSwitching Capacity: 16A230VVoltage Supply: 230VContacts: Singlepole,singlethrowDimensions: 120x122x55mmIngress Protection: IP65Special Features: SuppliedwithM20cablegland

GP-T with cover in place

GP-T with cover removed

showing set-point adjustment knobs

CONTROLS Thermostats, Continued

Page 67: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 67

CONTROLSRST-TP Energy Saving Tamperproof Thermostat

ApplicationTheRST-TPisasimplewallmountedthermostatforcontrollingavarietyofspaceheaters.Thetemperatureadjustingknobisconcealed.

SpecificationAdjustable Range +5⁰Cto+25⁰CMounting SurfaceSwitching Capacity 20A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitablyratedcontactor)Voltage Supply 230VContacts Singlepole,singlethrowDimensions: 85x85x35mmIngress Protection IP30Special Features Concealedtemperature adjustment.Optionalshear-offcover fixingscrewsprovided.Integralheatanticipatorimprovescontrol accuracy.

ERC-T1 Thermostat for Snow and Ice Melting

ApplicationTheERC-T1providesaneconomicmeansofcontrollingERCsnowandicemeltingmats.

SpecificationAdjustable Range: 0to10⁰CAdjustable Run-on Time: 0to5hoursMounting: DIN-railSwitching Capacity: 16A230V(largerloadsand3-phaseloadscanbeswitchedviaa suitablyratedcontactor)Voltage Supply: 230VContacts: Singlepole,singlethrowDimensions: 86x52x59mmIngress Protection: IP20Ground Sensor (loose): DetectingmoistureandtemperatureIP68Sensor Dimensions: 60diax32with10mcableSpecial Features: LEDindicators:poweron/moisturedetected/low temperaturedetected/outputon

CS-1 Wall Mounted ControllerApplicationTheCS-1controllerhasbeendevelopedspecificallyforusewithBNThermic’s800,SCH,CHSandRHrangeofcommercialfanassistedheaters

SpecificationMounting SurfaceSwitching ManualSettings On/Off/HighHeat/LowHeat/Fan- onlyVoltage Supply 230VDimensions 90x149x45mmIngress protection: IP30

Page 68: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143268

CONT

ROLS

CONTROLS Shortwave Heater ControlsBNThermic’srangeofshortwaveheatercontrolshasbeendevisedtoensurethelowestpossiblerunningcostsforaheatingsystem.

TS-3 Pre-programmed Push Button TimerApplication• GenerallyusedwithshortwaveradiantheaterssuchasBNThermic’sHWP2patio

heaters• Anenergysavingdevicepreventingshortwaveheatersbeingenergised

unnecessarily• Safe to install and leave outdoors

SpecificationMounting Surface

Adjustable Time Delay 2minutesto2hours

Switching Capacity 16A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)

Voltage Supply 230V

Contacts Singlepole,singlethrow

Dimensions 85x85x67mm

Ingress protection: IP66suitableforoutdooruse

Special Features Bluelocatorlightilluminatedwhenheating‘off’RedLEDindicates1minuteofoperationremaining

TS-4 Push Button Timer (User Selectable Time Delay)Application• GenerallyusedwithshortwaveradiantheaterssuchaBNThermic’sHNSeries

ShortwaveInfraredHeaters• Anenergysavingdevicepreventingshortwaveheatersbeingenergised

unnecessarily• Forindooruseinfacilitiessuchasschoolbuildingsandcommunityhalls

SpecificationMounting Recessedinto25mm(minimum)back-box

Time Delay Userselects15minute/30minute/1hour/2hour

Switching Capacity 13A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)

Voltage Supply 230V

Contacts Singlepole,singlethrow

Dimensions 85x85x31mm

Ingress protection: IP20notsuitableforoutdooruse

Special Features LEDindicates2minutesofoperationremainingTimesettingcanbechangedatanytimeduringcycleProvidesameansofswitchingoffheating

Page 69: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 69

CONTROLSVR-1 Dimmer SwitchApplicationSpecificallydesignedforusewithradiantheaters,theVR-1providesfineadjustmentofaheatintensity.

Specification

Mounting Surface

Output adjustment 0%to100%

Switching Capacity 13A230V(shortwaveinfraredheatersupto3kW230V)

Voltage Supply 230V

Dimensions 86x147x69mm

Ingress protection: IP20notsuitableforoutdooruse

Special Features Definiteclickto‘off’.

WH-402 Movement SensorApplicationIdealforusewithshortwavehalogenheaters,theWH-402improveseconomyswitchingoffheatingwhennomovementisdetected.Itissuitableforbothindoorandoutdooruse.

SpecificationMounting SurfaceSwitching Capacity 16A230V(largerloadsand3-phaseloadscanbeswitchedviaasuitableratedcontactor)Voltage Supply 230VSensing Range 12m180°(bothdistanceandanglecanbereduced)Time Delay 5secondsto18minutes(adjustable)Dimensions 65x83x115mmIngress protection: IP55suitableforoutdooruse

Page 70: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 53143270

JOIN

THE

THE

RMIC

NAT

ION

Environmental AwarenessBNThermichasrecentlyinstigatedseveralenvironmentalprogrammes.

Energy Saving ProductsThroughoutthiscatalogueyouwillseeourenergysavingicondrawingattentiontoproductsandcontrolsystemsthatmakethemostofeverykWconsumed.

Paper Use ReductionBNThermichasinvestedsignificantlyinITdevelopmentsenablingthecompanytoreduceitspaperusageby50%.Asaby-productofthisprogramme,customerordersarenowhandledmoreefficientlyhelpingthecompanytocloseinonitsobjectiveof100%ontimedeliveries.

RecyclingBNThermicbelievesstronglyintheprincipleofrecycling.Virtuallyallpackagingmaterialusedisbothrecycledandrecyclable.

For help in making the right

selection for your application

contact our Technical Sales

Team

BN Thermic and Electrical Wholesalers• BNThermicproductscanbe

orderedfromalmostallUKelectricalwholesalers

• Visit www.bnthermic.co.uk or call 01293547361fordetailsofawholesalerinyourarea

• Thispricelistshowslistprices–callyourpreferredwholesalerforyourtrade price

The BN Thermic Brand Promise• Weprovideheatingsystemsforjust

abouteverycommercialandindustrialapplication

• Weareexpertsinunderfloorheatingandcarryvaststocks

• Friendlyexperiencedstaffarealwaysavailabletoprovidetechnicalassistance

• Weofferafreedesignservice• Wecarryout‘freeofcharge’and‘noobligation’sitevisitsthroughouttheUK• Nextdaydeliveryisavailableforalmostallproducts

Company ProfileBNThermicpublisheditsfirst6-pagemonochromecataloguein2005.Wearenowproudtopresentourlatestfullcolourcataloguecontaining72pagesofproductinformation.Operatingfroman1800m²facilityinCrawleyWestSussex,BNThermicisguidedbyamanagementteamwithover80yearsofexperienceintheelectricheatingindustry.BNThermicheatingsystemsaredistributedtoallpartsoftheUKandbeyond,gainingareputationforreliabilityandvalue.

BN Thermic Headquarters at Crawley, West Sussex

Page 71: BN Thermic 2013-2014 Electric Heating Catalogue

web www.bnthermic.co.uk email [email protected] tel 01293 547361 fax 01293 531432 71

JOIN THE THERMIC NATION

join theGet the latest news

and have your say!

www.bnthermic.co.uk NEWSCheck back regularly for• Case Studies• Product Updates• An opportunity to add your comments

like us on facebookLet's get interactive!Here's where you can comment on• All things BN Thermic• All things Electric Heating• Life in general

follow us on TwitterWe tweet regularly (but not too regularly!)This is the place to find out about• New BN Thermic products• New marketing material• The latest BN Thermic news stories

Page 72: BN Thermic 2013-2014 Electric Heating Catalogue

Contact us for technical advice, free designs or detailed quotationBN Thermic Ltd34 Stephenson WayThree BridgesCrawleyWest SussexRH10 1TN

Tel 01293 547361Fax 01293 531432Email [email protected] www.bnthermic.co.uk

2013- 2014

Air Curtains

Fan Convector Heater

Terrace Heater

Touch-Screen Thermostat range

Underfloor Heating Foil Mats

Product GuideValid from 1st October 2013

Wireless Controls

new

new

new

specialists in

commercial and industrial heating

underfloor heating

and heating cables