bluedome - musson theatricalholzkirchen, de • ohmstrasse 3, 83607 holzkirchen, germany • tel +49...
TRANSCRIPT
BlueDomeETC®
1 of 4
BluesSystem LV Series
G E N E R A L I N F O R M A T I O N
BlueDomeBlueDome provides dimmable, omni-directional LED light designed to gently illuminate stairwells, lobbies, wing spaces and seating areas. The optional, snap-on eyelid accessory ensures that your BlueDomes provide safe illumination while conforming to the design needs of your venue.
APPLICATIONS • Onstage running lights• Auditoriums• Lobbies• Houses of worship• Museums• Studios
GENERAL• Must be used with BluesSystem Power Supply (see separate
datasheet)• Three-year warranty• Ambient operating temperature 0-40C / 32-104F• Indoor use only• ETL/cETL Listed
OPTICAL• Available in frosted or opaque lens options• Light spill masking accessories available• Single-color, 3W blue LED emitter
ELECTRICAL• Low Voltage 11-36VDC operating range• 3W LED consumes 85mA @ 36V (130mA @ 24V)• Three screw terminal connections on rear (power/ground/
control)• Must be used with BluesSystem power supply only• Supplied with wiring harness and Wago connector for easy
terminationMECHANICAL
• Supplied with two mounting screws• Supplied with choice of 4” mounting plate (see options
below)• Durable injection-molded housing
O R D E R I N G I N F O R M A T I O N
BS
BS D B F
EXAMPLE
BSDBF - BluesSystem BlueDome, Blue, Frosted.
MODEL BEAM/DOME
BluesSystemBS- DomeD-
COLOR
BlueB-
LENS TYPE
OpaqueO-FrostedF-
BLUEDOME
BlueDomeETC
2 of 4
BluesSystem LV Series
A C C E S S O R I E S
Both the eyelid and cowl accessories snap easily on to the front of a BlueBeam or BlueDome luminaire via the included accessory ring. The eyelid is designed for use with the BlueDome to shield glare when the luminaire is used at low level. The cowl is typically used on a BlueBeam that has been installed as a downlight, providing perfect light spill protection from on-stage areas.
M O U N T I N G P L A T E O P T I O N S
Each BlueBeam and BlueDome is supplied with your choice of 4” adaptor plate for mounting to standard electrical junction boxes
P O W E R S U P P LY O P T I O N S
SIX-ZONE RACK-MOUNT PSU
DMX
PWR
GND
OR
PWR
GND
PWR
GND
PWR
GND
PWR
GND
CTRL CTRLCTRL
ANALOG CONTROL
100-240V INPUT UNIT PERMANENTLY ON UNIT SWITCHED
+
-
+
-
WR
ND
P
G
C
WR
ND
PW
GN
CT
SIX-ZONE RACK-MOUNT PSU
DMX
P
G
OR
C
ANALOG CONTROL
100 240V INPUT
BSEL - EYELID BSC - COWL
BlueDomeETC
3 of 4
BluesSystem LV Series
Candela Plot
Candela Plot
Iso-Illuminance Diagram(Flat Surface Distribution)
Iso-Illuminance Diagram(Flat Surface Distribution)
BlueDome Opaque
Mode Candela Field
Lumens
Power
Consumption
Efficacy
(lpw)
Full Intensity 2.3 2.3 3.8 0.6
Metric conversions: For meters, multiply feet by 0.3048 For lux, multiply footcandles by 10.76
BlueDome Frosted
Mode Candela Field
Lumens
Power
Consumption
Efficacy
(lpw)
Full Intensity 5.1 3.2 3.8 0.8
Metric conversions: For meters, multiply feet by 0.3048 For lux, multiply footcandles by 10.76
Throw Distance (d) 10ft
3.0m
15ft
4.6m
20ft
6.1m
25.0ft
7.6m
Illuminance (fc) 0.023 0.010 0.006 0.004 1
Illuminance (lux) 0.25 0.11 0.06 0.04 10.76
Throw Distance (d) 10ft
3.0m
15ft
4.6m
20ft
6.1m
25.0ft
7.6m
Illuminance (fc) 0.051 0.023 0.013 0.008 1
Illuminance (lux) 0.55 0.24 0.14 0.09 10.76
P H O T O M E T R I C S
0
1
2
3
-40 -30 -20 -10 0 10 20 30 40
Can
dela
Degrees
X
Y
0
1
2
3
4
5
6
-40 -30 -20 -10 0 10 20 30 40
Can
dela
Degrees
X
Y
BlueDomeETC
4 of 4
BluesSystem LV Series
P H Y S I C A L
Product Dimensions Product Weight
MODEL HEIGHT WIDTH DEPTH MODEL WEIGHT SHIPPING WEIGHT
inches mm inches mm inches mm lbs kgs lbs kgs
BlueDome 2.62 67 2.62 67 1.42 36 BlueDome 0.12 0.055 0.265 0.12
2.62in67mm
1.89in48mm
1.42in36mm
0.51in13mm
2.00in51mm
BLUEDOME
4.07in104mm
4.07in104mm
2.04in52mm
1.54in39mm
2.01in51mm
2.36in60mm
3.63in92mm
3.63in92mm
4.06in103mm
4.06in103mm
ADAPTER PLATES
Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325Web • www.etcconnect.com • Copyright©2016 ETC. All Rights Reserved. All product information and specifications subject to change. 7492L1003 Rev. A Printed in USA 1/16