![Page 1: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/1.jpg)
BioStar 1.92 November 2016 Kate Yu
![Page 2: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/2.jpg)
1.92v
DISCLAIMER
This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the use of Suprema Inc. personnel. No part of it may be used, circulated, quoted, or reproduced for distribution outside Suprema Inc. If you are not the intended recipient of this report, you are hereby notified that the use, circulation, quoting, or reproducing of this report is strictly prohibited and may be unlawful. No representations or warranties, express or implied, are made as to, and no reliance should be placed on, the accuracy, fairness or completeness of the information presented or contained in this presentation. © 2016 Suprema Inc. All rights reserved
Contents
Supported BioStar2 Device, New Feature, Fixed Bug, and Issue
BioStar 1.92 Preview
BioStar 1 & BioStar 1.92
Frequently Asked Questions
Q&A
BioStar 1.92 Introduction
![Page 3: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/3.jpg)
1.92v
BioStar 1 & BioStar 1.92
![Page 4: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/4.jpg)
1.92v
BioStar1 & BioStar 1.92
BioStar 1.92
BioStar 1 : It’s a comprehensive access control and time & attendance management software featuring
TCP/IP-based system architecture with intelligent IP devices and terminals
![Page 5: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/5.jpg)
1.92v
BioStar1 & BioStar 1.92
BioStar 1.92
BioStar 1.92 : It is latest version of BioStar 1 launched on October-2016.
Many customers would like to keep the feature of BioStar1 like MSSQL and use BioStar 2
device with BioStar 1 device. To meet the customer’s requirement, we released BioStar 1.91
and then, BioStar 1.92.
![Page 6: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/6.jpg)
1.92v
BioStar1 & BioStar 1.92
BioStar 1.92
BioStar 1.92
BioStar 2 devices basically follow the rules and concepts of the BioStar 1 system. BioStar 2
devices have expanded sets of features and more capabilities than BioStar 1 devices. The
features and capabilities of BioStar 2 devices are constrained by the features and capabilities of
the BioStar 1 system to maintain the consistency with the BioStar 1 system.
![Page 7: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/7.jpg)
1.92v
![Page 8: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/8.jpg)
1.92v
BioStar1 & BioStar 1.92
BioStar 1.92
BioStar2 devices don’t support all feature like BioStar1 device even though you use BioStar 1
system.
BioStar 1.92 (Limitation)
![Page 9: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/9.jpg)
1.92v
BioStar1 & BioStar 1.92
BioStar 1.92
BioStar 1.92 (Limitation)
Anti-Passback Zone
Muster Zone
Entrance Limit Zone
Interlock Zone
Access Zone
Fire Alarm Zone Wiegand - User ID
Wiegand Legacy Mode
BioStar2 devices don’t support all feature like BioStar1 device even though you use BioStar 1
system.
Only APB and Fire alarm zone can be supported by BioStar2 RS485 Master and Slave device.
Command Card
Unlock Time/Lock Time
[Use Relay] option for T&A key
![Page 10: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/10.jpg)
1.92v
Supported BioStar2 device, New Feature, Fixed Bug, Bug
![Page 11: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/11.jpg)
1.92v
Supported BioStar 2 Devices
BioStar 1.92
BioEntry W2
October 2015 BioStar 1.9
June 2016 BioStar 1.91
October 2016 BioStar 1.92
BioStar 1 Device & BioStar1 FW
BioStation A2 BioStation 2 BioStation L2 Secure IO 2
BioStation A2 BioStation 2 BioStation L2 BioEntry W2 Secure IO 2
![Page 12: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/12.jpg)
1.92v
Supported BioStar 2 Devices : Limitation
BioStar 1.92
BioStar 1.x devices must have BioStar 1.x firmware loaded onto the devices.
BioLite Net, BioEntry W, BioEntry Plus, Xpass, and Xpass S2 with BioStar 2 firmware will not be
compatible with BioStar 1.92.
BioStar 1 Firmware only
![Page 13: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/13.jpg)
1.92v
![Page 14: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/14.jpg)
1.92v
New Feature & Fixed Bug
BioStar 1.92
New feature Support BioEnty W2 except Multi Wiegand Format
![Page 15: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/15.jpg)
1.92v
New Feature & Fixed Bug
BioStar 1.92
New feature Support Output port of BioStar2 device for a log event
- Log event: Auth Success, Auth Fail, Auth Duress, Access Not Granted, Door Opened, Door
Closed
Auth Success
![Page 16: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/16.jpg)
1.92v
New Feature & Fixed Bug
BioStar 1.92
Limited New feature Doesn’t support for “Access Granted Input” and “Access Not Granted Input” like BioStar 1
device
![Page 17: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/17.jpg)
1.92v
![Page 18: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/18.jpg)
1.92v
New Feature & Fixed Bug
BioStar 1.92
Bug fix Fixed the connection issue of BioStar 1.91 if there are more than 64 BioStar2 devices
1 2 3 … 63 64
BioStar 1.91
BioStar 2 Devices
![Page 19: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/19.jpg)
1.92v
New Feature & Fixed Bug
BioStar 1.92
Bug fix
The server port of BioStar2 device was
not available to use the changed port.
The server port will be 51212 internally
even though you change the port to
another number.
Fixed that the port of Biostar 2.x server of BioStar Server 1.91 was not changed by user setting
![Page 20: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/20.jpg)
1.92v
New Feature & Fixed Bug
BioStar 1.92
Bug fix
Fixed that the error of BioStar 1.91 into the report menu
The error occurred during uploading a
log of BioStar2 device.
![Page 21: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/21.jpg)
1.92v
![Page 22: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/22.jpg)
1.92v
Bug
BioStar 1.92
Bug
- Unstable connection during uploading the image log of BioStation A2.
The client of BioStar1.92 is
stopped if BioStation A2
has an image log more
than 16 k of the image log
size.
![Page 23: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/23.jpg)
1.92v
Bug
BioStar 1.92
Bug
- Stopped BioStar Server if BioStation A2 is ‘device->server’ mode and uses image
log.
The server of BioStar1.92 is stopped if
BioStation A2 has an image log more
than 16 k of the image log size.
Size: 18.9KB Size: 11.5KB
![Page 24: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/24.jpg)
1.92v
Bug
BioStar 1.92
Temporal solution
- Apply the modified BS_SDK_V2.dll to C:\Program Files\BioStar\server.
Download link is as follows. http://webhard.suprema.co.kr//ExFd/13695/29428.dll
![Page 25: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/25.jpg)
1.92v
BioStar 1.92 Preview
![Page 26: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/26.jpg)
1.92v
Preview: Who Should Use BIOSTAR 1.92?
BioStar 1.92
1. The expansion of BioStar 1 system If a customer who uses BioStar1 wants to use BioStar 2 devices,
they can use BioStar 1.92.
![Page 27: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/27.jpg)
1.92v
Preview: Who Should Use BIOSTAR 1.92?
BioStar 1.92
2. The limitation of project requirement If one of a project requirement is MS-SQL, MySQL, or Oracle to use Suprema system,
you can choose BioStar 1.92.
![Page 28: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/28.jpg)
1.92v
Preview: Who Should Not Use BIOSTAR 1.92?
BioStar 1.92
1. BioStar 1 device only If the customer wants to use BioStar 1 device only, you should use BioStar 1.9.
2. Performance issue If there is performance issue of BioStar 1.9 or lower version, you don’t need to upgrade
the system. Please contact us first.
![Page 29: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/29.jpg)
1.92v
Preview: When is BioStar 1.92 SDK released?
BioStar 1.92
There is no BioStar 1.92 SDK.
You should use Biostar 1 SDK for V1 devices and use BioStar2 Device SDK for V2 devices.
BioStar 1.9
SDK
Biostar 1.92
+
=
BioStar 2 Device SDK V2.3.0
![Page 30: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/30.jpg)
1.92v
Preview: BioStar Server Config
BioStar 1.92
V1 port: 1480 (Modifiable)
V2 port: 51212 (Modifiable)
![Page 31: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/31.jpg)
1.92v
Preview: Connection Method (Server > Device)
BioStar 1.92
V1 Devices V2 Devices
Direct Mode (Default) Server > Device (Default)
TCP 1480 TCP 1470 or
1471
TCP 1480 TCP 51211
![Page 32: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/32.jpg)
1.92v
BioStar 1.92
V1 Devices V2 Devices
Preview: Connection Method (Device > Server)
Server Mode Device > Server
TCP 1480 TCP 1480
TCP 51212 TCP 1480
![Page 33: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/33.jpg)
1.92v
Remaining pages are about 30 pages..
![Page 34: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/34.jpg)
1.92v
BioStar 1.92 Introduction 1. Device Menu
1 2 3 4 5
![Page 35: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/35.jpg)
1.92v
Device Connection Mode
Device
BioStar 2 devices will be always located on the BioStar
Server tree regardless of the connection mode.
If the connection mode is server-to-device mode,
devices are located under Device tree. If the connection
mode is device-to-server mode, the devices are located
on the BioStar Server tree.
![Page 36: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/36.jpg)
1.92v
RS485 (Master-Slave)
Device
When you configure a Master-Slave configuration through
RS485, you cannot use BioStar 1 devices with BioStar 2
devices. The RS485 protocol between BioStar 1 and 2
devices is different and are not compatible.
The RS485 mode of BioStar 2 devices
have three different values: Default, Host
and Slave.
When the device’s RS485 mode is
“Default”, the device works as a
standalone device or its RS485 mode
changes to “Slave” if it is connected to a
“Host” device through the RS485
interface.
V2 Devices
RS485
![Page 37: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/37.jpg)
1.92v
Template On Card
Device
• Secure credential cards not supported
• Template on Card supported; V2 devices reads both CSN of
a card and template on card as default
• Access on Card issues from BioStar 2 cannot be used in
BioStar 1.92
• Cannot use same Template on Card on V1 and V2 devices
V1 Devices
V2 Devices
Template on Card option
enable/disable feature for
V1 devices
Template on Cared
![Page 38: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/38.jpg)
1.92v
Input/Output (Trigger & Action)
Device
V1 Devices
Input/Output configuration available for
V1 devices
![Page 39: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/39.jpg)
1.92v
Input/Output (Trigger & Action)
Device
V2 devices only has the Input tab,
because the BioStar 2 system has
adopted the Trigger-and-Action
concept
V2 Devices
![Page 40: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/40.jpg)
1.92v
Device
V1 Devices
V2 Devices
T&A
Terminology differences only
V1.x V2.x (Device Menu)
Not use = Not use
Manual = By User
Manual Fix = Last Choice
Auto change = By Schedule
Event Fix = Fixed
![Page 41: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/41.jpg)
1.92v
Wiegand
Device
• V2 devices support Extended mode only
• V2 devices support Card ID In/Out only
![Page 42: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/42.jpg)
1.92v
BioStar 1.92 Introduction 2.User Menu
1 2 3 4 5
![Page 43: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/43.jpg)
1.92v
User Information
User
You should transfer user information to RS485host and RS485 slave devices
V1 Devices
V2 Devices
You should transfer user information to RS485host only
RS485 Host RS485 Slave
RS485 Host RS485 Slave
BioStar Client
BioStar Client
TCP
TCP
RS485
RS485
![Page 44: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/44.jpg)
1.92v
User Information
User
V2 Devices
• Department: All BioStar 2 devices do not store department information on the devices.
(BioStation and BioStation T2 only store department information)
![Page 45: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/45.jpg)
1.92v
User Information
User
V2 Devices
• PIN: BioStar 2 devices encrypt PIN data whereas BioStar 1 devices do not. When you transfer users
from BioStar to BioStar 2 devices, the PIN data is encrypted and transferred, allowing users to use
PIN authentication on BioStar 2 devices. However, if you retrieve users with PIN from BioStar 2
devices, the PIN data is not usable because it is one-way encrypted.
Transfer
1
2
3
ID 1
PIN
ID 1
PIN
Transfer ID 1
![Page 46: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/46.jpg)
1.92v
User Information
User
V2 Devices
1
ID 1
PIN ID 1
PIN
Transfer
ID 1
PIN
![Page 47: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/47.jpg)
1.92v
User Information
User
V2 Devices
• Enrolling a user on slave devices: With BioStar 2 devices, you cannot enroll users on the slave
devices. On the BioStar 2 system, a slave device works as a dummy device and does not have users
on the device.
![Page 48: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/48.jpg)
1.92v
User Profile
User
• BioStation, BioStation T2, X-Station
supported
V1 Devices
V2 Devices
• BioStation A2 supported only
• BioStation 2, BioStation L2 is not supported
• Transfer user image only
• Other features such as private Message,
Display Count, Display Duration are not
supported
![Page 49: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/49.jpg)
1.92v
Private Authentication Mode
User
• Not supported in V2 devices
V1 Devices
V2 Devices
• Normal User / Admin User
V1 Devices
V2 Devices
• Admin User = Device Administrator
• Unable to assign device
administrator per device
• Supported in V1 devices only
![Page 50: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/50.jpg)
1.92v
Bypass Card
User
• Bypass Card feature not supported in V2
devices
• When card is issued with “Bypass Card”, it
will trigger private authentication mode to
turn on “Card Only” mode
V1 Devices
V2 Devices
• Supported in V1 devices only
![Page 51: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/51.jpg)
1.92v
Mifare Card Reading Mode (MSB/LSB)
MIFARE card only
• The byte order of a MIFARE card on BioStar 2 devices is opposite to the one on BioStar 1
devices. If the byte order of BioStar 1 devices is set to MSB, you need to set the byte order of
BioStar 2 devices to LSB and vice versa.
User
V1 Devices
V2 Devices
![Page 52: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/52.jpg)
1.92v
Mifare Card Reading Mode (MSB/LSB)
User
3829120554 11100100 00111011 10111110 00101010
MSB of BioStation Byte Order
3829120554 11100100 00111011 10111110 00101010
LSB of BioStation2 Byte Order
717110244 0010101 010111110 00111011 11100100
MSB of BioStation2 Byte Order
717110244 0010101 010111110 00111011 11100100
LSB of BioStation Byte Order
![Page 53: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/53.jpg)
1.92v
Find User
User
• All features supported
V1 Devices
V2 Devices
• Read Card not supported
![Page 54: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/54.jpg)
1.92v
BioStar 1.92 Introduction 3.Access Group
1 2 3 4 5
![Page 55: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/55.jpg)
1.92v
Default Access Group
Access Group
V2 Devices
With BioStar 2 devices, users are allowed to gain access when
there are no door assigned to the device. It is working just like
“Full Access”.
However, as soon as the device is assigned to a door, then it
will work like “No Access” and block users without access
groups.
![Page 56: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/56.jpg)
1.92v
Default Access Group
Access Group
V1 Devices
V2 Devices
With V1 devices, if the device’s default access group is set to Full
Access, whether the user can gain access depends on the
matching access group. If the time when the authentication takes
place is not within the time schedule of the matching access
group, the user will not gain access. If the time when the
authentication takes place is within the time schedule, the user will
gain access.
With BioStar 2 devices, if the device’s default access group is
Full Access, the device does not use access group information
to determine if the user is allowed to gain access. This means
that the user will always gain access if the credential matching
(e.g. fingerprint, card) succeeds.
Skip
![Page 57: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/57.jpg)
1.92v
BioStar 1.92 Introduction 4. Door & Zone
1 2 3 4 5
![Page 58: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/58.jpg)
1.92v
Dual Authentication (Double Mode)
Door
Double Mode: Configure a
device to open only when
authenticating credentials of
two persons
V1 Devices
![Page 59: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/59.jpg)
1.92v
Dual Authentication (Double Mode)
Door
V2 Devices
Dual Authentication = Double Mode
* Configure a door to open only when
authenticating credentials of two persons (an
ordinary user and an administrator).
![Page 60: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/60.jpg)
1.92v
Door / Zone Configuration
Door
• Cannot use BioStar 1 devices with BioStar 2 devices for a door.
• For example, if you’ve specified a BioStar 1 device as an entry device on
the door configuration, you can choose BioStar 1 devices only as an exit
device
• Cannot use BioStar 1 devices with BioStar 2 device for a zone.
• For example, if you’ve specified BioStar 1 devices in an Anti-
passback zone as member devices, you cannot add BioStar 2
devices to the zone.
• BioStar 2 devices are only support Local Zone.
• BioStar 2 devices are supported in Anti-passback zone and Fire
Alarm zone only.
![Page 61: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/61.jpg)
1.92v
Door / Zone Configuration
Door
Global Zone : TCP/IP and RS485 based, BioStar Server is zone master
Local Zone : RS485 based, RS485 master device is zone master * zone master : makes logical decisions and controls functionality
RS-485
TCP/IP
Local Zone Global Zone
BioStar 2 Server
M S
Global Zone Master
Zone of Biostar 2 device
![Page 62: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/62.jpg)
1.92v
Unlock Time / Lock Time
Door
• All features supported
V1 Devices
V2 Devices
• Unlock Time / Lock Time not
supported
• Driven By, Unlock Trigger not
supported
![Page 63: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/63.jpg)
1.92v
Held Open / Forced Open Alarm
Door
V1 Devices
V2 Devices
Held Open will be OFF when the door is closed
• Held Open / Forced Open alarm will NOT be OFF when the door is closed
• Administrators must click [Release alarm] from Monitoring tab
![Page 64: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/64.jpg)
1.92v
BioStar 1.92 Introduction 5.Monitoring
1 2 3 4 5
![Page 65: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/65.jpg)
1.92v
Monitoring
Monitoring
• All features supported
V1 Devices
V2 Devices
• Upload log > USB not supported
![Page 66: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/66.jpg)
1.92v
Demonstration
![Page 67: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/67.jpg)
1.92v
![Page 68: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/68.jpg)
1.92v
Frequently Asked Questions
![Page 69: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/69.jpg)
1.92v
1. What firmware versions are compatible with BS1.92? (For 1.x 2.x) -> All firmware for V1 devices -> BS2: V1.3.1_20160921 / BS A2 : V1.2.1_20160921 / BS L2 : V1.1.1_20160921 / BEW2: V1.0.1_20160920 or higher versions 2. Can we integrate the database from 1.8 to 1.92? -> The database structure is almost the same between BioStar 1.8 and BioStar 1.92-> You can upgrade your BioStar from old version to the latest version without issue. 3. Will the USB memory be supported in future updates? -> We do not have any plan for USB support yet. 4. Will Ver2 Readers be compatible for Server matching? -> Yes
Frequently Asked Questions
![Page 70: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/70.jpg)
1.92v
5. Is DM20 supported in Bx.1? -> Unfortunately, no 6. How many cards per user can we issue for BioStar 2 devices? -> Only 1 7. In 1.92 , how many access groups per user in V2 devices? -> Same as V1 devices, 4. 8. Will there be a tool to import BioStar 2 DB to BioStar 1.92? -> Unfortunately, no. 9. Is Biomini compatible with BioStar 1.92? -> Yes, Biomini and Biomini plus are compatible with BioStar 1.92. Biomini slim and BioMini 2 are not compatible.
Frequently Asked Questions
![Page 71: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/71.jpg)
Q&A
![Page 72: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/72.jpg)
Effective way to integrate with 3rd party card and RF reader
Device will verify the validity of card ID received from the RF reader and will react
upon the user information stored in device. (Unabled to distinguish the RF reader
generating the authentication event)
Wiegand Input (Legacy - 1)
Wiegand Legacy mode
Door
Door lock
Door sensor
Exit Button
Out In
Wiegand
![Page 73: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/73.jpg)
Wiegand Input (Legacy – 2)
Wiegand Legacy mode
Card : 12345
11000000111001
User ID Card Info Template Password
BypassOption
1 12345 Yes 1111 No
Wiegand
RF Reader
![Page 74: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/74.jpg)
Leave log information with own device IDs. APB-zone configurable.
RF Reader will be treated as an independent device. No extra verification is
necessary
Wiegand Input (Extended Mode - 1)
Wiegand Extended mode
Door 1
Door lock
Door sensor
Out In
Wiegand
Door 2
Door lock
Door sensor
Out
Door 3
Door lock
Door sensor
Wiegand
RS485
Out
![Page 75: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/75.jpg)
Wiegand Input (Extended Mode – 3)
Wiegand Extended mode
RF Reader
Card : 1234
5
11000000111001
User ID Card Info Template Password
BypassOption
1 12345 Yes 1111 No
243
0
(Device log)
Wiegand
![Page 76: BioStar 1 - BioConnect · This presentation contains information that is confidential and proprietary to Suprema Inc. and is solely for the ... BioEntry W, BioEntry Plus, ... Download](https://reader036.vdocuments.site/reader036/viewer/2022082213/5af54d5f7f8b9a9e598dded3/html5/thumbnails/76.jpg)
Wiegand Input (Extended Mode – 2)
Wiegand Extended mode
243
0