Classical definition of biosensor
![Page 3: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/3.jpg)
Current Definition for Biosensors:
A sensor that integrates a biological element with a physiochemical transducer to produce an electronic signal proportional to a single analyte which is then conveyed to a
detector.
www.imec.be/ovinter/static_research/BioHome.shtml
![Page 4: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/4.jpg)
D. Grieshaber, R. MacKenzie, J. Voeroes and E. Reimhult, Sensors, 2008, 8, 1400–1458
![Page 5: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/5.jpg)
Physical sensor physical quantity: temperature, pressure, weight or force
Chemical sensor chemicals including ionsBiosensors biomolecules usually through
chemical or biological interactionBiomedical sensors: analytes relative to
disease, healthcare or environmental protection. Ex: gases: CO2, O2, NH3. Hormones, glucose, etc
Types of sensors
![Page 6: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/6.jpg)
Computer-related technology Molecular medicine Home and self‐care products Minimally invasive procedures Combination device/drug products Organ substitute and assist devices
Biosensor classification based on FDA
![Page 7: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/7.jpg)
SensitivityLinearityApplication range (Low/High limitation)Response timeLifetimeReproducibilityInterference (selectivity)
Basic Sensor Performance
![Page 8: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/8.jpg)
Biosensor 1ST Component: Sensing Element
The component used to bind the target molecule.
http://www.chemistry.wustl.edu/~edudev/LabTutorials/HIV/DrugStrategies.html
Must be highly specific, stable under storage conditions, and immobilized.
• DNA : ssDNA to complementary DNA • Enzymes: with specificity and catalysis• Antibody/antigen: immuno‐based, highly specific and strong binding• Receptors/analytes : high specificity• Chemical/chemical : chemical reactions• Gas/solid materials : (metal, oxides, polymers… etc.)
![Page 9: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/9.jpg)
2ND Component: TransducerActs as an interface, measuring the physical change that occurs with the
reaction at the bioreceptor then transforming that energy into measurable electrical output.
• Electrochemical sensors: Potentiometric & voltammetric (amperometric)•Semiconductor‐based sensors: FETs, Schottky diodes• Piezoelectric sensors: QCM, SAW• Optical sensors: surface plasmon resonance (SPR), surface‐enhanced Raman scattering.
![Page 10: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/10.jpg)
3RD Component: Detector
Signals from the transducer are passed to a microprocessor where they are amplified and
analyzed.
The data is then converted to concentration units and
transferred to a display or/and data storage device.
www.modernmike.com
![Page 11: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/11.jpg)
Static Characteristics
• Accuracy • Resolution• Reproducibility• Statistical control• Static sensitivity - the ratio of the incremental output quantity to the incremental input quantity. - zero drift, sensitivity drift• Linearity• Input ranges• Input impedance
![Page 12: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/12.jpg)
Static sensitivity
![Page 13: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/13.jpg)
Linearity
![Page 14: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/14.jpg)
Calibration
![Page 15: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/15.jpg)
Error of non-linearity
![Page 16: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/16.jpg)
Static and dynamic characteristics of the system
![Page 17: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/17.jpg)
Biosensors for biotoxins and biologicalpathogens
This scheme demonstrates the application of the infection process to ricin detection, since ricin specifically recognizes cell surface oligosaccharides, and the sugar based nanomaterials (A) were designed for use in surface plasmon resonance (B) and (C), and in a colloidal gold colorimetric assay for the qualitative detection of the toxin (D)
Uzawa et al., Biosens. Bioelectron., 2008, 24, 923–927
![Page 18: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/18.jpg)
(A) Schematic showing the biosensor structure and membrane assembly consisting of the application pad, adsorption pad, and the capture pad. (B) Detection scheme of the biosensor based on antibodies and magnetic separation of the analyte from mixed samples
Luo et al., Biosens.Bioelectron., 2010, 26,
1612–1617
![Page 19: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/19.jpg)
DNA magnetic-based sensor
Schematic of the bio-barcode assay with (A) formation of the magnetic nanoparticles (MNPs) with the DNA probe complex including the target DNA and the barcode DNA on gold nanoparticles (Au-NPs) and (B) the separation of the complex and release of the barcode DNA
Zhang et al., Biosens. Bioelectron., 2009
![Page 20: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/20.jpg)
Biosensor on food quality test
Scheme of the process used to directly detect Salmonella on tomato surfaces using magnetoelastic biosensors
Li et al., Biosens. Bioelectron., 2010, 26, 1313–1319
![Page 21: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/21.jpg)
Medical biosensorsImmunology and infectious disease diagnosis
Layout of the single-cell barcode chip (SCBC) system. (a and b) Optical image of an SCBC system and cells isolated in microchambers; (c) scheme of cytokine detection by antibody barcode array; (d) scanned antibody barcode array; (e) calibration curve for recombinant cytokine proteins.
Ma et al., Nat. Med., 2011, 17, 738–743.
![Page 22: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/22.jpg)
Cancer Diagnostic and monitoring – circulating tumor cell
(A) In the absence of target molecules, VEGF165, unfolded VEGF165 aptamer is electrostatically bound to a positively charged PLL-coated gold nanoparticle (GNP) surface and surface-enhanced fluorescence (SEF) of Cy3B conjugated with the VEGF165 aptamer is created by both a metal interaction increasing the radiative fluorescent decay rate of Cy3B and the local surface plasmon resonance (LSPR) enhancing the intensity of an incident light. (B) The interaction of the VEGF165 aptamer with its target induces the reversible conformation change of the aptamer and, consequently, the decreased electrostatic binding force. (C) As a result, the target-binding interaction of the aptamer causes the irreversible detachment of the aptamer from the GNP surface and avoids the SEF effect of Cy3B
Cho et al.,ACS Nano, 2012, 6, 7607–7614
![Page 23: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/23.jpg)
Application in neuroscience
A mushroom-shaped microelectrode (gMmE) engulfed by a neuron for electrical coupling. (a and b) Schematic illustration of a neuron on a gold-spine electrode (a) and a flat electrode (b); (c) electron micrograph image of the cross section of a cell which engulfs three gold spine electrodes; (d) transmission electron micrograph of a gMmE engulfed by a cell; (e) three neurons cultured on gold spine electrode arrays; (f) action potential signal monitored from 8 spine electrodes.
Hai et al., Nat. Methods, 2010, 7200–202.
![Page 24: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/24.jpg)
Trends over 4 decades
![Page 25: Biosensor in Medical Application](https://reader037.vdocuments.site/reader037/viewer/2022110404/568130fb550346895d9726f6/html5/thumbnails/25.jpg)
Thank you…