bio-cascade, inc clean air and water systems distributors and service providers for: clean air plant...

28
Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Upload: adan-richman

Post on 15-Dec-2015

224 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Bio-Cascade, IncClean Air and Water Systems

Distributors and Service Providers for:

Clean Air Plant (CAP©)

and Clean Water Plant (CWP©)

Page 2: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CAP© and CWP© History

• 1996 - Introduction of CAP Clean Air Plant for control of Indoor Air Quality (IAQ), World’s 1st and only Biological IAQ Control System

• 2002: Business Achievement Award, Technology Merit Award for biological air and water cleaning systems for industry, Environmental Business Journal

Page 3: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Technology Background

• Dr. Sam Sofer PhD, PE; Principal engineer and inventor of the bio-hygienic products produced by the company.

• Air and Water Solutions Inc. based in NJ. Headquarters for manufacturing, research and development.

Page 4: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

How CAP/CWP works

• Humans and animals consume food therefore capturing the energy from the food source and reducing it to carbon dioxide,water and solids.

• Biological Oxidation is a natural reaction where micro-organisms capture the energy in an organic substance (food source) and use it for the oxidation process.

Technology : Biological Oxidation

Page 5: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• This allows biological oxidation to take place without a large increase in temperature or energy usage. The results of this are CO2, water and inert bio-solids.

• As contaminants come in contact with micro-organisms, they are biologically oxidized to CO2 and water. Heavy metals and solids are consolidated and rendered harmless.

 

Biological Oxidation (continued)

Page 6: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Bio-hygienics

• Contaminants and odors that are persistent travel on particulates.

• Most large particles will travel with air flow and can be vented.

• Small particles, the ones which are most harmful, are resistant to normal air flow and cannot be vented.

(bi'o-hi jen'ikx); The application of compact treatment plants utilizing bio-oxidation for indoor and outdoor applications

Page 7: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• These particulates are electrically charged.

• Their motion is controlled by electrical fields not by air flow.

• For these reasons, many odors linger even when an area is exhausted.

• CAP© neutralizes contaminants in the air and CAP© neutralizes contaminants in the air and creates an electrically neutral “clean zone.” creates an electrically neutral “clean zone.”

Bio-hygienics

Page 8: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• Contaminants, both positively and negatively charged, are attracted to this neutral clean zone, where they are captured in the unit and biologically oxidized.

• CWP© work the same way, creating a clean water zone. Contaminants move to the clean zone, are drawn into the unit, where they are biologically oxidized.

Bio-hygienics (continued)

Page 9: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Substantial cost savings• Superior technology to

– Carbon - substantially more economical

– Thermal destruction

– Removes and digests small particles and more that HEPA cannot handle.

•Single technology, single solution

•Very low maintenance

•Can be installed modularly to meet growing demands

Page 10: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• Save on energy by reducing or eliminating costly venting and air

exchange!

• CAP systems are fully sustainable “Green” Technology!

Help environmental efforts!

Page 11: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Technology will eliminate nuisance odor and hazardous problems including :

• Anatomy labs• Waste transfer and treatment plants• Diesel and gasoline fumes• Carbon Monoxide• Mold and other spores• Paint fumes. (Paint will even dry faster!)• VOC’s• Particulates• Hair and nail salon fumes • And much more…

Page 12: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• CWP for real solutions to waste water discharge regulations. More economical than conventional treatments

• CAPs and CWPs are the only 100% bio-systems that address air and water contaminants.

Page 13: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CAP can even be customized to help reduce power plant emissions!

Page 14: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

0

500000

1000000

1500000

2000000

2500000

Amount of 0.3 Micron Particles

10:19 11:20 12:21 13:22 14:23 15:24

One Minute Samples Taken Hourly - First Shift

Office Bio Cascade Particulate Study

7/24/2007

9/14/2007

Real Data

Page 15: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

0

500000

1000000

1500000

2000000

2500000

3000000

Amount of 0.3 Micron Particles

16:25 17:26 18:27 19:28 20:29 21:30 22:31

One Minute Samples Taken Hourly -Second Shift

BET Office Area Bio Cascade Particulate Study

7/24/2007

9/14/2007

Page 16: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Machine Operation

• The CAP™ Machine is can be modified to fit both stationary and portable applications.

• The size of the machine is based on both area covered and amount of pollution present

• Dual outlet power supply to run pump and fan.

Page 17: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• Water must be added as needed(daily in most cases). Automatic water feed can be installed on larger machines.

• Heaters can be added for exterior applications to prevent water freeze.

CAP™ requirements for normal operation

Page 18: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• BioOx© is the Bio-Enzyme microbial media used to consume pollution.

• Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation).

• BioOx added monthly or more frequently as needed.

Bio-Ox® Natural Media

Page 19: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

• The more pollution,the more BioOx needed.

• Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems.

Page 20: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Trash Transfer Station Applications

CAP 5000 with Rodent Intake Guards

   

   

 

CAP™ 5000

Page 21: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

•Can be made portable

•Will cover up to 3,000 sq.ft.

•10 lbs. of pollution per day

CAP™ 90

Page 22: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CAP™ 600 • Covers areas over 5,000 sq.ft.

• Destroys up to 60 lbs. of pollution per day

• Interior and exterior applications

Page 23: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Compare Indoor Air Cleaners

Type Cleaner Gases VOC’S Particulates Bio-Hygienics Safety

Ozone

Ionizer

UV

HEPA

(all air filters)

Carbon Canister

CAP

Technology Evaluation Table for Indoor Air Cleaners

Page 24: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CAP™ Machine SpecificationsModel Equiv.

Flow Rate (cfm)

Pollution Destruction (lbs/day)*

BioOx®

Usage

Size & Weight (US) Power

Consumption

Area Model Cleans

Typical Application

NEW CAP-50 500 5 8 oz startup

2 oz/week for 2 mos.

Thereafter 2 oz/month

12” sq x 15”

18 lbs

30 W

Up to 800 ft2 Room, office

NEW CAP-75 520 7 8 oz startup

4 oz/week for 2 mos.

Thereafter 4 oz/month

12” sq x 20”

20 lbs

30 W

Up to 1500 ft2 Small house, office

NEW CAP-80 1000 10 16 oz startup

4 oz/week for 2 mos.

Thereafter 4 oz/month

12” sq x 24”

25 lbs

30 W

Up to 2000 ft2 Medium office, garage, shop,

salon, schoolroom

CAP-90 Industrial Model

1000 10 16 oz startup

4 oz/week for 2 mos.

Thereafter 4 oz/month

15” sq x 32”

35 lbs

40 W

Up to 3000 ft2 Office, plant, garage,

commercial & small industry

Page 25: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CAP™ Machine Specifications (continued)Model Equiv.

Flow Rate (cfm)

Pollution Destruction (lbs/day)*

BioOx®

Usage

Size & Weight (US) Power

Consumption

Area Model Cleans Typical Application

CAP-600 7500 60 1 gal. startup

16 oz/week for 2 mos.

Thereafter 16 oz/month

30” dia x 48”

26” at base

200 lbs

175 W

Units designed to

handle commercial

and industrial areas

of 5000 ft2 and

larger, with heavy

pollution load

Small-medium industry, plant,

warehouse, lab, loading dock,

restaurant, bar, hotel, parking

garage

CAP-2500 12500 250 2 gal. startup

48 oz/week for 2 mos.

Thereafter 48 oz/month

36” dia x 50”

+ 12-24” fan housing

300 lbs

438 W

Industry, plant,

terminal,

indoor/outdoor,

heavy pollutionCAP-5000 19400 500 3 gal. startup

½ gal./week for 2 mos.

Thereafter 64 oz/month

52” dia x 50”

+ 12-24” fan housing

500 lbs

500 W

CAP-X Series (all models above)

All environments. Specifically designed for

extremely concentrated and

toxic air contaminants

Concentrated discharges from mixers, reactors and other similar

equipment

Page 26: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CWP™ Machine SpecificationsModel Equiv.

Flow Rate

(gpm)

Pollution Destruction (lbs/day)*

BioOx®

Usage

Size & Weight (US) Power

Consumption

Area Model Cleans

Typical Application

CWP-100 2 10 4 oz./mo.

Startup: 16 oz. Then 4 oz/week for 2 mos.

12” sq x 20”

30 lbs

Small, compact and

portable

For sinks, fish tanks, ponds. Small space applications

CWP-175 20 40 16 oz/mo.

Startup: 32 oz. Then 8 oz/week for 2 mos.

12” sq x 20”

20 lbs

30 W

Small-scale industry, industrial

wastewater, waste tank

contents, fuel-contaminated home sumps

or direct treatment of ground water

CWP-SVE 20-50 60 16 oz/mo.

Startup: 1 gal. Then 16 oz/week for 2 mos.

30” dia x 8”

100 lbs

Saves on carbon costs

For industrial applications, fish tanks,

wells, ponds, small lakes.

Page 27: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

CWP™ Machine Specifications (cont.)

Model Equiv. Flow Rate

(gpm)

Pollution Destruction (lbs/day)*

BioOx®

Usage

Size & Weight (US) Power

Consumption

Area Model Cleans

Typical Application

CWP-1000 50 100 24 oz./mo.

Startup: 1 gal.

Then 24 oz/week for 2 mos.

36” dia x 48”

250 lbs. Cleans large

amounts of

liquid.

Designed for

sudden

increase in

flow.

Wastewater,

chemical

waste streams,

waste tank

contents.

Large volume

streams or

surface water

runoff.

Direct

treatment of

groundwater.

CWP-2500 50-100 250 48 oz./mo.

Startup: 2 gal.

Then 48 oz/week for 2 mos.

36” dia x 50”

250 lbs.

CWP-5000 100-200

500 64 oz./mo.

Startup: 3 gal.

Then ½ gal./week for 2 mos.

52” dia x 50”

350 lbs.

CWP-25000 100-500

2500 2.5 gal./mo.

Startup: 10gal.

Then 1 gal./week for 2 mos.

72” dia x 84”

600 lbs.

Page 28: Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

For more information

or to contact us:

www.Bio-Cascade.com