bio-cascade, inc clean air and water systems distributors and service providers for: clean air plant...
TRANSCRIPT
Bio-Cascade, IncClean Air and Water Systems
Distributors and Service Providers for:
Clean Air Plant (CAP©)
and Clean Water Plant (CWP©)
CAP© and CWP© History
• 1996 - Introduction of CAP Clean Air Plant for control of Indoor Air Quality (IAQ), World’s 1st and only Biological IAQ Control System
• 2002: Business Achievement Award, Technology Merit Award for biological air and water cleaning systems for industry, Environmental Business Journal
Technology Background
• Dr. Sam Sofer PhD, PE; Principal engineer and inventor of the bio-hygienic products produced by the company.
• Air and Water Solutions Inc. based in NJ. Headquarters for manufacturing, research and development.
How CAP/CWP works
• Humans and animals consume food therefore capturing the energy from the food source and reducing it to carbon dioxide,water and solids.
• Biological Oxidation is a natural reaction where micro-organisms capture the energy in an organic substance (food source) and use it for the oxidation process.
Technology : Biological Oxidation
• This allows biological oxidation to take place without a large increase in temperature or energy usage. The results of this are CO2, water and inert bio-solids.
• As contaminants come in contact with micro-organisms, they are biologically oxidized to CO2 and water. Heavy metals and solids are consolidated and rendered harmless.
Biological Oxidation (continued)
Bio-hygienics
• Contaminants and odors that are persistent travel on particulates.
• Most large particles will travel with air flow and can be vented.
• Small particles, the ones which are most harmful, are resistant to normal air flow and cannot be vented.
(bi'o-hi jen'ikx); The application of compact treatment plants utilizing bio-oxidation for indoor and outdoor applications
• These particulates are electrically charged.
• Their motion is controlled by electrical fields not by air flow.
• For these reasons, many odors linger even when an area is exhausted.
• CAP© neutralizes contaminants in the air and CAP© neutralizes contaminants in the air and creates an electrically neutral “clean zone.” creates an electrically neutral “clean zone.”
Bio-hygienics
• Contaminants, both positively and negatively charged, are attracted to this neutral clean zone, where they are captured in the unit and biologically oxidized.
• CWP© work the same way, creating a clean water zone. Contaminants move to the clean zone, are drawn into the unit, where they are biologically oxidized.
Bio-hygienics (continued)
Substantial cost savings• Superior technology to
– Carbon - substantially more economical
– Thermal destruction
– Removes and digests small particles and more that HEPA cannot handle.
•Single technology, single solution
•Very low maintenance
•Can be installed modularly to meet growing demands
• Save on energy by reducing or eliminating costly venting and air
exchange!
• CAP systems are fully sustainable “Green” Technology!
Help environmental efforts!
Technology will eliminate nuisance odor and hazardous problems including :
• Anatomy labs• Waste transfer and treatment plants• Diesel and gasoline fumes• Carbon Monoxide• Mold and other spores• Paint fumes. (Paint will even dry faster!)• VOC’s• Particulates• Hair and nail salon fumes • And much more…
• CWP for real solutions to waste water discharge regulations. More economical than conventional treatments
• CAPs and CWPs are the only 100% bio-systems that address air and water contaminants.
CAP can even be customized to help reduce power plant emissions!
0
500000
1000000
1500000
2000000
2500000
Amount of 0.3 Micron Particles
10:19 11:20 12:21 13:22 14:23 15:24
One Minute Samples Taken Hourly - First Shift
Office Bio Cascade Particulate Study
7/24/2007
9/14/2007
Real Data
0
500000
1000000
1500000
2000000
2500000
3000000
Amount of 0.3 Micron Particles
16:25 17:26 18:27 19:28 20:29 21:30 22:31
One Minute Samples Taken Hourly -Second Shift
BET Office Area Bio Cascade Particulate Study
7/24/2007
9/14/2007
Machine Operation
• The CAP™ Machine is can be modified to fit both stationary and portable applications.
• The size of the machine is based on both area covered and amount of pollution present
• Dual outlet power supply to run pump and fan.
• Water must be added as needed(daily in most cases). Automatic water feed can be installed on larger machines.
• Heaters can be added for exterior applications to prevent water freeze.
CAP™ requirements for normal operation
• BioOx© is the Bio-Enzyme microbial media used to consume pollution.
• Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation).
• BioOx added monthly or more frequently as needed.
Bio-Ox® Natural Media
• The more pollution,the more BioOx needed.
• Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems.
Trash Transfer Station Applications
CAP 5000 with Rodent Intake Guards
CAP™ 5000
•Can be made portable
•Will cover up to 3,000 sq.ft.
•10 lbs. of pollution per day
CAP™ 90
CAP™ 600 • Covers areas over 5,000 sq.ft.
• Destroys up to 60 lbs. of pollution per day
• Interior and exterior applications
Compare Indoor Air Cleaners
Type Cleaner Gases VOC’S Particulates Bio-Hygienics Safety
Ozone
Ionizer
UV
HEPA
(all air filters)
Carbon Canister
CAP
Technology Evaluation Table for Indoor Air Cleaners
CAP™ Machine SpecificationsModel Equiv.
Flow Rate (cfm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans
Typical Application
NEW CAP-50 500 5 8 oz startup
2 oz/week for 2 mos.
Thereafter 2 oz/month
12” sq x 15”
18 lbs
30 W
Up to 800 ft2 Room, office
NEW CAP-75 520 7 8 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
12” sq x 20”
20 lbs
30 W
Up to 1500 ft2 Small house, office
NEW CAP-80 1000 10 16 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
12” sq x 24”
25 lbs
30 W
Up to 2000 ft2 Medium office, garage, shop,
salon, schoolroom
CAP-90 Industrial Model
1000 10 16 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
15” sq x 32”
35 lbs
40 W
Up to 3000 ft2 Office, plant, garage,
commercial & small industry
CAP™ Machine Specifications (continued)Model Equiv.
Flow Rate (cfm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans Typical Application
CAP-600 7500 60 1 gal. startup
16 oz/week for 2 mos.
Thereafter 16 oz/month
30” dia x 48”
26” at base
200 lbs
175 W
Units designed to
handle commercial
and industrial areas
of 5000 ft2 and
larger, with heavy
pollution load
Small-medium industry, plant,
warehouse, lab, loading dock,
restaurant, bar, hotel, parking
garage
CAP-2500 12500 250 2 gal. startup
48 oz/week for 2 mos.
Thereafter 48 oz/month
36” dia x 50”
+ 12-24” fan housing
300 lbs
438 W
Industry, plant,
terminal,
indoor/outdoor,
heavy pollutionCAP-5000 19400 500 3 gal. startup
½ gal./week for 2 mos.
Thereafter 64 oz/month
52” dia x 50”
+ 12-24” fan housing
500 lbs
500 W
CAP-X Series (all models above)
All environments. Specifically designed for
extremely concentrated and
toxic air contaminants
Concentrated discharges from mixers, reactors and other similar
equipment
CWP™ Machine SpecificationsModel Equiv.
Flow Rate
(gpm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans
Typical Application
CWP-100 2 10 4 oz./mo.
Startup: 16 oz. Then 4 oz/week for 2 mos.
12” sq x 20”
30 lbs
Small, compact and
portable
For sinks, fish tanks, ponds. Small space applications
CWP-175 20 40 16 oz/mo.
Startup: 32 oz. Then 8 oz/week for 2 mos.
12” sq x 20”
20 lbs
30 W
Small-scale industry, industrial
wastewater, waste tank
contents, fuel-contaminated home sumps
or direct treatment of ground water
CWP-SVE 20-50 60 16 oz/mo.
Startup: 1 gal. Then 16 oz/week for 2 mos.
30” dia x 8”
100 lbs
Saves on carbon costs
For industrial applications, fish tanks,
wells, ponds, small lakes.
CWP™ Machine Specifications (cont.)
Model Equiv. Flow Rate
(gpm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans
Typical Application
CWP-1000 50 100 24 oz./mo.
Startup: 1 gal.
Then 24 oz/week for 2 mos.
36” dia x 48”
250 lbs. Cleans large
amounts of
liquid.
Designed for
sudden
increase in
flow.
Wastewater,
chemical
waste streams,
waste tank
contents.
Large volume
streams or
surface water
runoff.
Direct
treatment of
groundwater.
CWP-2500 50-100 250 48 oz./mo.
Startup: 2 gal.
Then 48 oz/week for 2 mos.
36” dia x 50”
250 lbs.
CWP-5000 100-200
500 64 oz./mo.
Startup: 3 gal.
Then ½ gal./week for 2 mos.
52” dia x 50”
350 lbs.
CWP-25000 100-500
2500 2.5 gal./mo.
Startup: 10gal.
Then 1 gal./week for 2 mos.
72” dia x 84”
600 lbs.
For more information
or to contact us:
www.Bio-Cascade.com