bg 64 details
DESCRIPTION
BG-64TRANSCRIPT
BG-
BG-6
-64 The BG-6access netinteroperaincluding
64 OverThe BG-6cage with
Figure -1:
The shelf
Two p
One M
Two X
One fa
Seven
The BG-6
The BG-6two powe
The BG-6expansionsupplies, a
The follow
Table Erro
Name
MCP64
XIO64_1
XIO16_4
SMD1B
SMS4
64 is a miniatutworks, offereability with thSDH, PDH, d
rview 64 shelf is hou
all interfaces
BG-64 front v
consists of th
power supply
MCP64 slot
XIO64 card sl
an unit (FCU_
n traffic card s
64 can be insta
64 is fed by -4r supply mod
64 subrack cann shelf used toa fan unit, and
wing table list
r! No text of sp
Descr
Main
Crossand 1 Crossand 4 2 x ST
1 x ST
ure, low-cost,ed as part of the XDM Proddata, DCC, m
used in a 243 s accessible fr
view
he following p
(INF_64) mo
lots
_64) slot
slots (Tslots)
alled in 2,200
48 VDC powedule slots for r
n be expandeo expand the Bd three tributa
ts the module
pecified style in
ription
control card
-connect, timinx STM-64 inte-connect, timinx STM-16 inte
TM-1o/e modu
TM-4 module
, flexible reduthe overall ECduct Line and management, a
mm deep, 46rom the front
parts:
odule slots
0 mm or 2,600
er sources. Twredundant pow
d via expansiBG-30B. Theary slots..
es that can be
n document.-1:
ng control, erface card ng control, erface card ule
undant ADM-CI Telecom soBG Product L
and other net-
65 mm wide, aof the unit.
0 mm ETSI r
wo INF-64 mwer supply.
ion shelf, the e BG-30E she
configured in
BG-64 cards
MS XSA&
√
√
√
-64/MADM-1olution. It supLine in all asp-wide functio
and 88 mm h
acks, or in 19
modules can be
BG-30E. Thielf contains tw
n each slot in
and modules
S &B
TS1 to TS7
√
√
√
√
16 MSPP for pports pects,
ons.
igh equipmen
9” racks.
e configured i
is is the same wo power
the BG-64.
PS A&B
nt
in
Name Description MS XS A&B
TS1 to TS7
PS A&B
SMQ1&4 4 x STM-1/4 module √
SMS16 1 x STM-16 module √
PME1_211 21 x E1 module, 120 Ω √
PM345_3 3 x DS-3/E3 module √
DMFE_4_L1 4 x 10/100BaseT module, L1 functionality
√
DMFX_4_L1 4 x 100Base-FX module, L1 functionality
√
DMFE_4_L2 4 x 10/100BaseT module, L2 functionality (MPLS ready)
√
DMFX_4_L2 4 x 100Base-FX module, L1 functionality (MPLS ready)
√
DMGE_4_L1 4 x GbE module, L1 functionality √
DMGE_2_L2 2 x GbE module, L2 functionality with MPLS support
√
DMGE_4_L2 4 x GbE module, L2 functionality with MPLS support
√
DMEoP_4 4 x EoP module with total WAN bandwidth of 32 x E1 and L2 functionality
√
INF_64 Power filter unit (-48 VDC) √
BG-30E Overview The BG-30E shelf is housed in a 240 mm deep, 465 mm wide, and 88 mm high equipment cage with all interfaces accessible from the front. The shelf consists of three expansion cards, redundant power feed modules, and an extractable fan module. All cards in the BG-30E are connected using a backplane that supports one traffic connector for the connection between the BG-30E and the BG-30B or BG-64.
NOTE: the BG-30E can be used to expand traffic for the BG-30B and BG-64 shelves. All information described for the BG-30E is applicable for both shelves.
1 This module/card can provide only balanced E1 interfaces directly. For unbalanced E1 interfaces, an external DDF with balanced-to-unbalanced conversion should be used.
A BG-30E shelf is an extension or slave unit of the BG-30B or BG-64 and should always be connected to one of these shelves. The fan unit, used to cool the system, is extractable and located on the right side of the shelf. The fan control system is on the MCP30 or MCP64 in accordance with the type of shelf it is being installed on.
Figure -2: BG-30E front view
The BG-30E houses three traffic expansion slots supporting different types of PDH, SDH, data, and PCM interface expansion cards.
Either 220 VAC or -48 VDC power feeds can be selected. BG-30E has one slot that is used for configuring the power input module. Two types can be configured: INF_30E and AC_CONV-30E:
INF_30E, used for -48 VDC power feed, provides two D-type connectors for external power line connection, and supports dual power feed.
AC_CONV-30E is used for 220 VAC power feed to implement AC/DC conversion. It supports external power line connection through a special power connector.
NOTE: Adding a BG-30E expansion unit to a working BG-30B in the field is a non-traffic-affecting operation.
BG-30E Expansion Traffic Cards The BG-30E has three expansion card slots, which can be configured with expansion cards such as PE1_63, P345_3E, MPS_2G_8F, SM_10E, S1_4, S4_1, TP21_2, and TPS1_1 cards. All expansion cards are accessible from the front and provide cabling directly through the front panels. These extension cards support live insertion for fast maintenance and recovery.
The following table lists the modules that can be configured in each slot of the BG-30E.
Table Error! No text of specified style in document.-2: List of modules for BG-30E
Name Description ES1 ES2 ES3 PS
PE1_632 63 x E1 card, 120 Ω √ √ √
P345_3E 3 x DS-3/E3 card √ √ √
MPS_2G_8F L2 card supporting 2 x GbE combo ports and 8 x 10/100BaseT ports, MPLS feature and up to 64 EoS/MoT ports with total bandwidth of 4 x VC-4
√ √ √
2 This module/card can provide only balanced E1 interfaces directly. For unbalanced E1 interfaces, an external DDF with balanced-to-unbalanced conversion should be used.
Name Description ES1 ES2 ES3 PS
SM_10E DXC1/0 and PCM interfaces card (N × 64 Kbps)
√ √ √
S1_4 4 × STM-1o/e card √ √ √
S4_1 1 × STM-4o card √ √ √
TP21_2 21 x E1 IOP card √ √ √
TPS1_1 3 x E3/DS-3, 4 x STM-1/e IOP card
√ √ √
TP63_1 63 x E1 IOP card √
INF_30E Power filter unit (-48 VDC)
√