BE1-700V
URD-V812-1012570 STATE ROUTE 143, HIGHLAND, ILLINOIS 62249 USA PHONE 618-654-2341 FAX 618-654-2351
The BE1-700V is a compact multifunction numeric relay that provides phase,zero sequence, and negative sequence voltage protection including over andunder frequency, plus control and metering functions in an integrated system.Four shot reclosing with separate Pilot Initiate is available as an option. Anonboard Ethernet option can provide Modbus/TCP connectivity or can provideweb and email capabilities.
ADVANTAGES• All of the advantages of a fully numeric product in an economical "voltage
only" protection package.
• Compact design requires minimal panel space for underfrequency andundervoltage load shedding applications.
• Adds Oscillography, Sequence of Events, and Metering when singlefunction voltage relays are replaced with the BE1-700V.
• Zero sequence voltage (3V0) used to detect single phase ground faults onhigh resistance or ungrounded systems can be calculated based on theapplied 3-phase 4-wire sensing voltage, or applied from a separate zerosequence source (optional VX input).
• With the optional 4-shot recloser, including a pilot initiate path andauxiliary voltage input, replace existing network (transmission, sub-transmission) automatic reclosing schemes.
• BESTlogic provides the user with complete flexibility in configuring aprotection and control system.
• Optional BESTNet Ethernet package provides metering and status webpages, settings and configuration via Ethernet, and email notification ofuser-defined events.
INSTRUCTION MANUALRequest publication 9376700990
MODBUS™ INSTRUCTION MANUALRequest publication 9376700991
ADDITIONAL INFORMATION
WINDOWS® SOFTWAREInterface for setting and communicating with Basler protection productsAn evaluation copy of BESTWAVEPlus viewer and manual for viewing oscillographyfiles stored in COMTRADE format are provided with the relay. Validation and updatesof the program may be obtained from www.BESTWAVEPLUS.com.
BE1-700VDIGITAL
VOLTAGE/FREQUENCYPROTECTIVE RELAY
Available with
Easy Ethernet
BESTNet
BESTNet
BESTNet
BESTNet
BESTNet
FEATURESPages 2 and 3
APPLICATIONSPage 3
FUNCTIONALDESCRIPTION
Pages 4-7
BESTlogicPages 8 and 9
SPECIFICATIONSPages 10 and 11
ORDERINGINFORMATION
Page 12
DEVICE FUNCTIONS
24 25 27 47
59 60 62 81
79
Option
OptionOption
Ethernet
Option
Modbus
BE1-700V
2
FEATURES
PROTECTION• Phase Undervoltage and Overvoltage elements: 27P,
127P, 59P, 159P. Elements use a 1 of 3, 2 of 3, or 3of 3 logic, and monitor either line-line or line-groundvoltages.
• Auxiliary Undervoltage and Overvoltage elements:27X, 59X, 159X. Elements monitor either fundamentalor third harmonic on the optional auxiliary 4th VTinput, or fundamental phase residual, 3V0, of thephase inputs.
• Overexcitation, volts per Hertz element: 24• Negative Sequence Overvoltage element: 47• Over/Under Frequency elements: 81, 181, 281, 381,
481, 581• Each 81 element can be assigned to monitor 3 phase
VT input (VP) or optional Auxiliary voltage input (VX).• Two general purpose logic timers: 62, 162• Programmable Logic using BESTLogic• Two protection setting groups with external or
automatic (cold load pickup, load, and unbalance)selection modes
• Sync check with dead line/dead bus voltage monitorlogic, 25, 25VM (Optional VX)
• Fuse loss detection protects against false trip due toloss of voltage sensing: 60FL
CONTROL• Optional four shot recloser, including separate pilot
and time delayed reclose initiates, with zonesequence coordination and sequence controlledprotective element blocking functions.
• Virtual breaker control switch—controllable fromboth HMI and com. ports: 101
• Two virtual selector switches—controllable fromboth HMI and com. ports: 43 and 143
• Communication port control of 101, 43, and 143switches allows for SCADA control of relay andbreaker
INSTRUMENTATION• Real time A, B, C phase voltage and frequency, and
calculated neutral and negative sequence voltage
REPORTS• Breaker operations counter
FAULT RECORDING• 255 event sequence of events report with I/O and
alarm sub-reports• Fault Reporting; 1 or 2 oscillography records per
fault report• 16 fault summary reports; two most recent Fault
Summary Records saved to nonvolatile memory• Total number of oscillography records settable
from 6 to 16• Total of 240 cycles oscillography memory @ 12
samples/cycle• Oscillography records can be stored in
COMTRADE 1991 or COMTRADE 1999 formats
COMMUNICATION PORTS• Two independent general purpose communica-
tion ports- Front RS-232 ASCII communications- Rear RS-485 ASCII or optional Modbus™
protocols• IRIG-B time sync (demodulated), TTL• Optional 10/100 BaseT Ethernet port with BESTNet
Easy Ethernet or with Modbus/TCP protocol
SELF TEST AND ALARM FUNCTIONS• Relay fail, major alarm, and minor alarm LEDs,
and failsafe alarm output contact• Extensive internal diagnostics monitor all internal
functions of the relay• More than 20 additional alarm points—
programmable for major or minor priorityIncluding:- Trip circuit voltage and continuity monitor- Closed circuit monitor via BESTlogic
PROGRAMMABLE I/O• Four programmable inputs• Five programmable outputs and one dedicated
programmable alarm output
HARDWARE FEATURES• Flash Memory for upgrading embedded
programming without changing chips• Integral HMI with 2x16 character display• Compact panel mount case with integral mounting
studs for a clean installation. Less than 3/8" projec-tion in front of panel.
BE1-700V
3
APPLICATIONS
The BE1-700V Digital Voltage/Frequency Protective Relay provides single and three phase, zero sequence, andnegative sequence voltage protection including over and under frequency. Its unique capabilities make it ideallysuited for applications with the following requirements. The BE1-700V is intended for use in:
• Applications that require the flexibility provided by wide setting ranges and multiple setting groups.• Applications that require the economy and space savings provided by a multifunction, multiphase unit. This one
unit can provide all of the voltage protection, as well as local and remote indication, metering, and controlfunctions required on a typical bus, feeder, or line.
• Applications where bus, feeder, or line voltages and frequencies must be monitored.• Any under or over voltage or frequency protection application, i.e. bus, feeder, line, motor, generator, cogenera-
tion, etc.• Applications that require a fundamental digital signal processing (DSP) algorithm to provide rejection of harmon-
ics and low transient overreach.• Applications where the capabilities of intelligent electronic devices (IEDs) are used to decrease relay costs and to
protect against abnormal situations.• Applications that require communication capability.• Applications using Ethernet communication, programmable email notifications, and live metering information via
an embedded web server (with BESTNet option).• Applications requiring Modbus/TCP Ethernet communications (with Modbus/TCP option).
BESTCOMS SOFTWAREFree, easy to use settings program
BESTCOMS allows you to:
• Enter settings and BESTlogic logic equations for the
BE1-700
• Save settings to a file
• Save BESTlogic logic schemes (without settings) to a
"Logic Library" file
• Print settings
• Upload and download settings via Serial port
• Upload and download settings via Ethernet (with
BESTNet option)
• View real-time metering and status when connected
to a relay
• View fault records and SER data when connected to
a relay
• View COMTRADE oscillographic records
(with included BESTWAVEPlus program)
• FREE! with every order
BESTCOMS Screen, showing at a glancewhich relay functions have been enabled
BE1-700V
FUNCTIONAL DESCRIPTION
The BE1-700V is a multifunction, numeric relay thatprovides a comprehensive mix of protective, controland metering functions in an integrated system. Thissystem is suitable for any voltage and frequencyapplication including bus, feeder, line, generator/motorapplications and cogeneration applications.
The unit has one set of three phase and neutral voltagesensing inputs to provide all common protectivefunctions for typical power system voltage and fre-quency protection applications.
Two independent communications ports, along withbuilt-in support for Modbus™ or Modbus/TCP, provideeasy access to integrating the protection, control,metering, and status monitoring functions into asubstation automation system. The standard IRIG-Bport provides time synchronization from a masterclock.
Real time metering provides voltage frequency telem-etry for the protection application. Contact sensinginputs and alarm monitoring functions provide real timestatus information. Remote control is provided byvirtual control and selector switches with select-before-operate control of programmable outputs.
BESTlogicBESTlogic programmable logic provides the user withhigh flexibility in configuring a protection and controlsystem.
Each of the protection and control functions in theBE1-700V is implemented as an independent functionblock that is equivalent to its single function, discretedevice counterpart. Each independent function blockhas all the inputs and outputs that the discretecomponent counterpart might have. Figures 7 and 7ashow each of the independent function blocks availablefor use in the BE1-700V. Programming BESTlogic isequivalent to choosing the devices required by yourprotection and control scheme and drawing schematicdiagrams to connect the inputs and outputs to obtainthe desired operational logic.
The BE1-700V relay can store, as user settings, oneuser programmable, custom logic scheme. To save youtime, several preprogrammed logic schemes also havebeen provided. Any of the preprogrammed schemesmay be copied into the logic settings without makingany additional BESTlogic settings.
BESTlogic provides the protection engineer with theflexibility to set up this powerful multifunction systemwith the same freedom that once was enjoyed withsingle function, discrete devices. It is no longer neces-sary to compromise your standard protection andoperating practices to deal with the limitations inprogrammability of previous multifunction devices.
Figures 1 through 4 show typical external connections,and Figure 6 shows rear panel connections.
4
BESTNet ETHERNET OPTION
BESTNet features include:• Embedded web server with metering, status,
and fault summary information*• Email alerts of as many as seven user-defined
conditions**• Full BESTCOMS support over Ethernet• Full Basler ASCII protocol for terminal mode
communications (TELNET) or customprogrammed application access
• Support for DHCP or static IP addressing.IP Discovery function included in BESTCOMS.
* A web browser with a Java™ Runtimeenvironment installed is required to view web pages.
** An external SMTP email server must be available to useemail alerts.
The BESTNet option connects your BE1-700V relay tothe wired world.
Available with
BESTNet
Easy EthernetModbus/TCP
ETHERNET OPTION
Instead of the BESTNet option, the BE1-700 can beordered with the Modbus/TCP option. With Modbus/TCP, your BE1-700 relay offers a true Modbus/TCPprotocol connection via an internal 10/100 BaseT port.No clumsy external adaptors are required. Simply plugin an Ethernet cable, and your BE1-700 is part of yourModbus/TCP network.
NOTE: Modbus/TCP and BESTNet are mutually exclusive. TheEthernet port can be used for BESTNet or Modbus/TCP, but notboth.
BE1-700V
Figure 1 - Accommodates a Variety of Common Voltage Connections
FUNCTIONAL DESCRIPTION, continued
5
BE1-700V
Figure 4 - Typical External Connections
FUNCTIONAL DESCRIPTION, continuedTypical application for the BE1-700V with reclosing option
6
Figure 2 - Bus Voltage Protectionincluding UF Load Shed
Figure 3 - Network Reclosing Application
BE1-700V
FUNCTIONAL DESCRIPTION, continued
Figure 6 - BE1-700V Voltage/Frequency Relay Rear Panel Connections
7
Figure 5 - Typical Application Single Line
Pluggable ConnectorsEach rear panel terminal block may be unplugged after removing its two
mounting screws. This allows prewiring of terminal blocks or replacement ofthe relay without wiring changes.
BE1-700V
10
• EN 61000-4-11 Voltage Dips and Interruptions• IEEE C37.90 Relays and Relay Systems with Electric
Power Apparatus• IEEE C37.90.1 2002 Surge Withstand Capability• IEEE C37.90.2 1995 Radiated Electromagnetic
Interference• IEC 68-1 Environmental Testing Part 1: General and
Guidance• IEC 68-2-1 1990 Test A. Cold• IEC 68-2-2 1974 Test B. Dry Heat• IEC 68-2-3 1969 Test Ca. Damp Heat• IEC 68-2-30 1980 Damp Heat Cyclic 12+12 Hour• IEC 68-2-56 1988 Damp Heat Steady State• IEC 255-4 Single Input Energizing Quantity
Measuring Relays with Dependent Specified Time• IEC 255-5 1977 Insulation Tests For Relays• IEC 255-6 Clause 9, Insulation for Electrical Relays• IEC 255-14 and IEC-255-15, Endurance Test for
Electrical Relay Contacts• IEC 255-21-1 Vibration Tests• IEC 255-21-2 Shock and Bump Tests• IEC 255-22-1 1988 1MHz Burst Disturbance• IEC 255-22-2 1996 Electrostatic Discharge• IEC 255-22-3 1989 Radiated Disturbance• IEC 255-22-4 1992 Fast Transient Disturbance
MECHANICAL ENVIRONMENT• Operating temperature range: -40°C to 70°C
(-40°F to 158°F)*• Storage temperature range: -40°C to 70°C
(-40°F to 158°F)*Display contrast may be impaired below -20°C.• Humidity: Qualified to IEC 68-2-38, 1st Edition
1974, Basic Environmental Test Procedures,Part 2: Test Z/AD: Composite TemperatureHumidity Cyclic Test
• Vibration: Qualified to IEC 255-21-1, Class 1• Shock: Qualified to IEC 255-21-2, Class 1
CERTIFICATIONS• CE Qualified to meet or exceed standards required
for distribution in the European Community.• UL recognized per Standard 508 and Standard
CAN/CSA-C22.2 Number 14-M91, UL File NumberE97033.
• GOST-R certified per the relevant standards ofGosstandart of Russia.
• Byelorussian certified.
CASE SIZE10.5" wide, 4.46" high, 7.81" behind panel(.29" front projection)(266.7 mm wide, 113.233 mm high, 198.49 mmbehind panel; 7.38 mm front projection)
SHIPPING WEIGHT4.33 pounds (1.96 kg) maximum
WARRANTY 7 years
GENERAL SPECIFICATIONS
PHASE AC VOLTAGE INPUTSContinuous: 300 V, Line to LineOne Sec. rating: 600 V, Line to NeutralBurden: Less than 1 VA @ 300Vac
AUXILIARY AC VOLTAGE INPUTContinuous: 150VOne Sec. rating: 600VBurden: Less than 1 VA @ 150Vac
A/D CONVERTERSampling Rate: 12/cycle, adjusted to input
frequency 10-75Hz
POWER SUPPLYOption 1: 48 VdcOption 2: 125 Vac/dcOption 3: 24 VdcOption 4: 250 Vac/dcOption 5: 125 Vac/dc,
extended holdup optionBurden: 6 W continuous, 8 W max.
with all outputs energized
OUTPUT CONTACTSMake and carry: 30 A (0.2 sec)Continuous: 7 ABreak: 0.3 A DC (L/R=0.04)
CONTROL INPUTSWetting Voltage range: Same as control power
supply option.
Turn-on Voltage Power Supply Option Range (VDC) Burden
1) 48 Vdc 26-38 V 23 k ohms2) 125 Vac/dc 69-100 V 53 k ohms3) 24 Vdc approx. 5 V 6 k ohms4) 250 Vac/dc 138-200 V 234 k ohms5) 125 Vac/dc* 69-100 V 53 k ohms
Control inputs recognize both DC and AC voltages.
* Extended holidup option. See style chart, page 12.
SERIAL COMMUNICATION PORTSResponse Time:<100mSec for metering and
control functionsBaud Rate: 300-19200Protocols: Front RS-232: ASCII
Rear RS-485: ASCII standard,Modbus optional
ETHERNET PORT (OPTIONAL)Type: 10/100 BaseT, RJ-45 connectorProtocols: BESTNet or Modbus/TCP, see Page 4
CONFORMS TO STANDARDS:• EN 61000-4-2 Electrostatic Discharge Immunity• EN 61000-4-5 Surge-Lightning Strikes• EN 61000-4-6 RF Conducted• EN 61000-4-8 Power Frequency Magnetic Field
BE1-700V
PERFORMANCE SPECIFICATIONS
VOLTS/HZ (24)Pickup: 0.5 - 6V/HzDelay Time: Inverse Squared Curve
DT ETTT = (M-1)2 TR = DR x FST x 100TT = Time to Trip TR = Time to ResetDT = Time Dial, Trip DR = Time Dial, Reset
Actual V/HzM = Pickup V/Hz ET = Elapsed TimeFST = Full Scale Trip Time (TT)
SYNC CHECK (25)Delta Phase Angle: 1 - 99 degreesDelta Voltage Magnitude: 1 - 20VDelta Frequency: 0.01 - 0.50Hz
SYNC CHECK, VOLTAGE MONITOR (25VM)Dead Threshold: 10 - 150VLive Threshold: 10 - 150VDropout Time Delay: 0.05 - 60.0secLogic: Dead Phase/Dead Aux.
Dead Phase/Live Aux.Live Phase/Dead Aux.
PHASE OVER/UNDERVOLTAGE (27P, 59P, 127P, 159)Mode: 1 of 3; 2 of 3; 3 of 3Pickup: 10.0-300VL-L or 10.0-300VL-NDelay Time: 0.050 - 600sec.
NEGATIVE SEQUENCE OVERVOLTAGE (47)Pickup: 1.0 - 300VL-NDelay Time: 0.05 - 600sec.
AUXILIARY / 3V0 OVER/UNDERVOLTAGE(27X, 59X, 159X)
Mode: Fundamental VX ,3 phase Residual (3V0),3rd Harmonic VX
Pickup: 1.0 - 150VDelay Time: 0.05 - 600 Sec.
GENERAL PURPOSE LOGIC TIMERS (62, 162)Mode: PU/DO
1 Shot, Non-Retrig.1 Shot, Retrig.IntegratingLatch
T1 and T2 Delay Time: 0.00 - 9999 Sec.Time Accuracy: ±0.5% or ±¾ cyc
RECLOSER (79)Mode: Power up to close,
Power up to lockoutReclose Attempts: 0 - 4 total attempts
1 pilot or delayed3 additional delayed
Reclose, Reset, Fail,Max. Cycle Timers: 0.10 - 600 Sec.Time Accuracy: ±0.5% or
+1¾ cyc/-0 cyc
VOLTAGE PICKUP ACCURACY (All 27, 47 and 59)Phase (VL-L or VL-N): ±2% or ±0.5VPhase 3V0 and V2: ±2% or ±0.5V
DEFINITE TIME ACCURACY UNLESS OTHERWISESTATED (All 27, 47 and 59)
Definite Time Accuracy: ±0.5% or ±1 cyc
SETTING GROUPSSetting Groups: 2Control Modes: Automatic: CLP;
Dynamic load or unbalanceExternal: Discrete input logic;Binary: Input Logic
METERINGPhase Voltage Range: 3W 0 - 300 VL-L
4W 0 - 300 VL-LPhase Voltage Accuracy: ±0.5% for
50V<VL-L<300VFrequency: 10 - 75HzFrequency Accuracy: 0.01Hz
BREAKER MONITORINGOp Counter Alarm Range: 0 - 99999
FREQUENCY (81, 181, 281, 381, 481, 581)Mode: Over, UnderPickup (O/U): 20 -70 HzOver/Undervoltage Inhibit: 15-150VDelay Time: 0.00-600 sec.Time Accuracy: ±0.5% or ±1 cyc
(plus 3 cyc recognitiontime), whichever isgreater
11
BE1-700V
www.basler.com
ORDERING
SAMPLE STYLE NUMBERThe style number identification chart below defines the electrical characteristics and operation features included inthe BE1-700V relay. For example, if the style number were BE1-700 N4R4X5N, the device would have the following:
BE1-700 Digital Protective Relay(N4) - 3-phase Sensing with Independent Auxiliary Input(R) - Reclosing(4) - 250 Vac/dc Power Supply(X) - Panel mount, non-drawout case(5) - Modbus over RS-485, BESTNet and ASCII over Ethernet(N) - Not applicable
12570 State Route 143, Highland, Illinois 62249-1074 USATel +1 618.654.2341 Fax +1 618.654.2351
e-mail: [email protected]
No. 59 Heshun Road Loufeng District (N),Suzhou Industrial Park, 215122, Suzhou, P.R.China
Tel +86(0)512 8227 2888 Fax +86(0)512 8227 2887e-mail: [email protected]
P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCETel +33 3.88.87.1010 Fax +33 3.88.87.0808
e-mail: [email protected]
55 Ubi Avenue 1 #03-05 Singapore 408935Tel +65 68.44.6445 Fax +65 65.68.44.8902
e-mail: [email protected]