battery control electronic module fred flor smiths aerospace, inc

18
BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC. Electronic Systems - Long Island tel: 631-467-5500, ext 347

Upload: astra-potter

Post on 31-Dec-2015

62 views

Category:

Documents


0 download

DESCRIPTION

BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC. Electronic Systems - Long Island tel: 631-467-5500, ext 347. Battery Control Electronic Module. Key Features Charger: Uses unregulated DC bus power Reduce battery capacity fade Extends battery maintenance interval - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

BATTERY CONTROL ELECTRONIC MODULEFRED FLOR

SMITHS AEROSPACE, INC.Electronic Systems - Long Islandtel: 631-467-5500, ext 347

Page 2: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

2© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Key Features

– Charger:

• Uses unregulated DC bus power

• Reduce battery capacity fade

• Extends battery maintenance interval

• Adaptable to Sealed Lead Acid or NiCd batteries

Page 3: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

3© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Key Features

– Limiter:

• Provides un-interruptible power during loss of DC buss

• Fills in any “holes”

Page 4: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

4© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Electrical Characteristics:

– Constant current : 30 Ampere max.

– Constant potential: 28.5 Volt nominal @ 15 Ampere max.

Page 5: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

5© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Limiter Fill-in Characteristics:

– 60 Ampere of current for 50ms, prior to Contactor closure

– Voltage drop < 1.25 Volts at 50 Ampere

Page 6: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

6© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Physical Characteristics:

– Size: 10 in. long x 9 in. wide x 3 in. high

– Weight: 10.0 pounds (4.6 kg) max.

– Cooling: Convection

Page 7: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

7© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

Page 8: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

8© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

Page 9: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

9© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

AIRCRAFTBATTERY

BYPASSSWITCH

BATTERY BUSS ISOLATED DC BUSS

OFF

BATT

EXT

ESSENTIAL DC BUSS

BATTERYSWITCH

ES

SE

NT

IAL

AC

BU

SS

REVERSECURRENT

RELAY

DCTRANSFORMER

RECTIFIERUNIT

BUS TIESWITCH

20

22

24

14

18

16

251

11

12

5

8

2 4 6 10

BATTERYCONTROL

ELECTRONICMODULE

200 AMPERECONTACTOR

Page 10: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

10© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Charger Electronics Module

Battery Control Electronic Module

Page 11: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

11© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Test Program– Mansfield Air National Guard Unit

• Two C-130’s Modified - January 2001• Flight Testing Started in March 2001• Scheduled to be a 1 Year Program• Equipment removed in October 2002

Page 12: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

12© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Test Program (cont)– Mansfield Air National Guard Unit

• Batteries–Maintenance Free Lead Acid

(30 A-H)»1 New Battery S/N R49803»1 Used Battery S/N R41390

Page 13: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

13© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Initial Battery Conditioning and Capacity Check

– Discharge Batteries

»Constant Current to 18vdc

– Re-charge Batteries

»Constant Potential

»Rest

Page 14: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

14© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Initial Battery Conditioning and Capacity Check (cont)

– Measure Initial Capacity

»Discharge Constant Current to 18VDC

– Battery Initial Capacity

»Battery S/N R49803 - 45 Amp-Hours

»Battery S/N R41390 - 37.5 Amp-Hours

Page 15: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

15© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

CAPACITYCHECK

AC#1 BATTERYS/N R49803

RESIDUAL CAPACITY

AC#2 BATTERYS/N R41390

RESIDUAL CAPACITY

MONTH/YR

INITIAL 45 A-H 37.5 A-H JAN ’01

Flight Test Evaluation Started MAR ‘01

30 DAYS 36 A-H 37.5 A-H APR ‘01

90 DAYS 39 A-H 37.5 A-H JUN ‘01

180 DAYS 37.5 A-H 39 A-H SEP ‘01

360 DAYS 33 A-H 22.5 A-H MAR ‘02

570 DAYS Equipment successfully removed fromthe aircraft with no Battery anomalies or

malfunctions

OCT ‘02

Page 16: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

16© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Test Summary

– Aircraft #90-1794 flew 864.3 Hours without a Battery malfunction or anomaly

– Aircraft #90-1795 flew 715.9 Hours without a Battery malfunction or anomaly

Page 17: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

17© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

Battery Control Electronic Module

• Test Summary (cont)

– Of the remaining 6 Aircraft at Mansfield, there were 8 instances of premature battery failure or low voltage problems on 4 aircraft. Two unmodified aircraft had no battery problems.

Page 18: BATTERY CONTROL ELECTRONIC MODULE FRED FLOR SMITHS AEROSPACE, INC

18© PROPRIETARY INFORMATION OF SMITHS AEROSPACE INC.www.smiths-aerospace.com

• For more information contact:– Fred Flor - Engineer

• tel: 631-467-5500 x347• [email protected]

– Joseph McHugh - Marketing• tel: 631-467-5500 x291• [email protected]

– Visit www.smiths-aerospace.com

Battery Control Electronic Module