barriersystems panel grid

12
CONTROLLED ENVIRONMENT 09 22 26.23 BarrierSystems PRODUCT GUIDE Fast. Easy. Customer Focused. ® PANEL GRID

Upload: others

Post on 03-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

controlled environment09 22 26.23

BarrierSystemsproduct guide

Fast. Easy. Customer Focused.®

PANEL GRID

2 BarrierSystems chicagometallic.com

Non-Fire RatedDouble Web

ApplicationsControlled environment facilities, semiconductor, phar-maceutical, aerospace, clean manufacturing areas, healthcare, food processing, precision instrument assembly rooms.

Features• Componentsandassembliesdesignedforusein

ISO 14644-1 controlled environment facilities (previ-ously Fed Standard 209E).

• Gridcomponentswithfactory-appliedgasketsrestrictairmovementbetweenplenumsandcleanprocessworkareas.

• Precisionplacementofgasketsongridflangeseliminates voids at panel modules and speeds up installation.

• Demountable“hook”crosstees(standardsystem)allowlargeareasofceilingtobeopenedeasily.

• Buttcutcrossteeskeepallcomponentsinsameplane improving appearance and sealing.

• Doublegasketedaluminumwallangleandchannelprovide tight closures at perimeters and minimize theneedforcaulking.

• Aluminumcapsonrunnersandteesimprovecorro-sion resistance of grid system.

BarrierSystemsBarrierGrid™ Suspension

13/8

Premium

Gasketed Wall Channel

Gasketed Main Tee

Gasketed Cross Tee (stab)

Standard

Gasketed Wall Channel

Gasketed Main Tee

Gasketed Cross Tee (hook)

11/2

11/2

15/16

Always up-to-date product information is available on the web

chicagometallic.com/barriergridchicagometallic.com/barrierpan

Chicago Metallic suspension systems meet a Class A Flame Spread Rating

IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed.

chicagometallic.comPRODUCT

UPDATES

USA and Canada: 800.323.7164 / fax: 800.222.3744 BarrierSystems 3chicagometallic.comPRODUCT

UPDATES

Product Dimensions Per Carton Number Length Height Face Feet Pieces Weight

Standard 15/16 BarrierGridMain Tee 200.01AG 12 11/2 15/16 300 25 93

Cross Tees - Hook-type 229.01AG 2 11/2 15/16 150 75 28 213.01AG 4 11/2 15/16 200 50 42

Cross Tees - Stab-type

1229.01AG 2 11/2 15/16 150 75 24 1215.01AG 4 11/2 15/16 200 50 42

Wall Molding

1406.01AG 10 11/8 1 150 15 52

Wall Channel

1446.01AG 10 15/8 1 120 12 52

Premium 1-3/8 BarrierGridMain Tee 600.01AG 12 11/2 15/16 240 20 86

Cross Tee - Stab-type 602.01AG 2 11/2 15/16 80 40 29 604.01AG 4 11/2 15/16 160 40 57

Wall Molding

1406.01AG 10 11/8 1 150 15 52

Wall Channel

1446.01AG 10 15/8 1 120 12 52

Suspension-BarrierGridComponentSlottingandHangerHolePlacementAlloveralllengthsshownarenominaldimensions.

200.01AG Main Tee: 24 slots 6 O.C.

213.01H Cross Tee (hook-type): Three slots, one at midpoint and twospaced12 each side of midpoint.

229.01AG Cross Tee (hook-type): No cross tee slots.1229.00AG and 602.01AG (stab-type) Tees: No cross tee slots.

200.01AG

229.01AG-213.01AG

1229.01AG

600.01AG

602.01AG / 604.01AG

1406.01AG

1446.01AG

600.01AG Main Tee: 24 slots 6 O.C.

1215.01AG (stab-type) Tee: Threeslots,oneatmidpointandtwospaced 12 each side of midpoint.

604.00AG (stab-type) Tee: One slot at midpoint.

4 BarrierSystems chicagometallic.com

BarrierPan™ I

Features• Texturedor smoothhighglossFRP facedwith1/2 gypsum

bonded to 1 foam.

Benefits• USDAaccepted.

• Withstandstherigorsoffrequentcleaningandoffersexceptionalcontrol of air and particulate movement from the plenum.

• Idealforareasrequiringthermalcontrol.

• R4Insulationrating.

BarrierSystemsBarrierPan™Panels

ApplicationsForcontrolledenvironmentfacilitiesrequiringdurable,highlymoistureresistant,lowparticulatesurfaces.Usewith15/16 or 13/8 gas-ketedCMCBarrierGrid™. All components and assemblies designed for use in ISO 14644 Class 5 controlled environment facilities.

BarrierPan™ II

Features• Aluminumskinbondedtohoneycombedplasticcore.

Benefits• Reversible,non-directional.

• USDAaccepted.

• SuitableforcleanroomsthatrequireISO5-8certification.

• Protectivepeelcoatforeaseofhandlingduringinstallation.

• Withstandstherigorsoffrequentcleaningandoffersex-ceptional control of air and particulate movement from the plenum.

• Excellentrigidity.

BarrierPan™ III

Features• AluminumskinwithHDPEcore.

Benefits• Reversible,non-directional.

• USDAaccepted.

• SuitableforcleanroomsthatrequireISO5-8certification.

• Idealforcleanroomsrequiringregularcleaning,moistureresistance.

• Excellentrigidity.

BarrierPan™ IV

Features• FRPskinwithHDPEcore.

Benefits• Reversible,non-directional.

• USDAaccepted.

• SuitableforcleanroomsthatrequireISO5-8certification.

• Idealforcleanroomsrequiringregularcleaning,moistureresistance.

• Excellentrigidity.

FRP face (textured or high gloss smooth)

Gypsum (1/2)

Foam (1)

Aluminum skinHoneycomb plastic core

Aluminum skinHDPE core

FRP skinHDPE core

Aluminum skin

Aluminum skin FRP skin

USA and Canada: 800.323.7164 / fax: 800.222.3744 BarrierSystems 5chicagometallic.comPRODUCT

UPDATES

Panels-BarrierPan

Product Panel Per Carton Number Size Sq. Ft. Pieces Weight

Lay-inSquareEdgeBarrierPanPanels—for15/16 or 1- 3/8BarrierGrid™

BarrierPan I – 1-1/2 8310.01 24 x 24 32 8 72 8310.01S 24 x 24 32 8 72 8311.01 24 x 48 32 4 72 8311.01S 24 x 48 32 4 72

BarrierPan II – 7/16 8312.01 24 x 24 32 8 24 8313.01 24 x 48 32 4 24

BarrierPan III – 1/4 8314.01 24 x 24 32 8 40 8315.01 24 x 48 32 4 40

BarrierPan IV – 1/4 8316.01 24 x 24 32 8 67 8317.01 24 x 48 32 4 67* Custom sizes available as Special Order - Consult CMC.

WallConditions

BarrierPan I

Panel and Wall Channel

Panel and Wall Angle

BarrierPan II

Panel and Wall Channel

Panel and Wall Angle

BarrierPan III

Panel and Wall Channel

Panel and Wall Angle

BarrierPan IV

Panel and Wall Channel

Panel and Wall Angle

6 BarrierSystems chicagometallic.com

ComponentData-BarrierGrid

Standard 15/16ExposedGasketedComponentLoadTestData(based on 1/360

spandeflection)

ALLOWABLE LOAD per ASTM C635

Hanger Spacing Main Tee Length 4 5 6 200 12 HeavyDuty 8.9 5.6 Cross Tee Length 1 20 2 30 3 4 5 6 8

1229 2 33.0

229 2 32.5

1215 4 10.7 To convert data into lb/ft2, divide on center spacing of component into lb/ft. Limited by safety factor of 2.

Hanger Positions for Non-Fire Rated Situations

This illustrates hanger positions for single fixtures in a field.Provideextrahangersfortandemfixtures.

Non-Fire Rated Assemblies

Premium1-3/8ExposedGasketedComponentLoadTestData(based on 1/360

spandeflection)

ALLOWABLE LOAD per ASTM C635

Hanger Spacing Main Tee Length 4 5 6 600 12 HeavyDuty Cross Tee Length 1 20 2 30 3 4 5 6 8

602 2 100.0

604 4 18.6 To convert data into lb/ft2, divide on center spacing of component into lb/ft. Limited by safety factor of 2.

Non-Fire Rated Assemblies

Hanger Positions for Non-Fire Rated Situations

This illustrates hanger positions for single fixtures in a field.Provide extra hangers for tandem fixtures.

Material Pressure Chemical Removable Peel Thermal Non- Magnetic Gloss Mfg Brand Composition Surface Washable Wash down Skin Protectant Performance Apps Surface Requirements ISO 14644 Rating Fire Rating

Chicago BarrierPan I FRP/Gyp/ Smooth/Textured Yes Yes Yes Excellent Yes Low/Med Class 5 Class C/A Metallic Foam FRP

BarrierPan II Alum w/ Plastic Smooth reversible, Yes Limited Yes Good Yes High Class 5 Class A Hollow core non-directional aluminum

BarrierPan III Aluminum face Smooth reversible, Yes Limited Yes Fair Yes High Class 5 Class A with High Density non-directional Poly-Ethylene aluminum core (HDPE)

BarrierPan IV FRP face with Smooth reversible, Yes Yes Yes Fair Yes Low/Med Class 5 Class C/A High Density non-directional Poly-Ethylene FRP core (HDPE)

Armstrong Cleanroom Mineral fiber Polyester film No No No Fair Yes Low Class 5 Class C Mylar

Cleanroom Mineral fiber Polyester film No No No Fair Yes Low Class 5 Class C Mylar

Cleanroom VL Mineral fiber Vinyl No No No Fair Yes Low Class 5 Class C (Perforated)

Cleanroom VL Mineral fiber Vinyl No No No Fair Yes Low Class 5 Class C (Non-perforated)

USG Clean Room Mineral fiber Vinyl No No No Fair Yes Low NA Class A Clima Plus

Clean Room Mineral fiber Vinyl No No No Fair Yes Low NA Class A Clima Plus

Sheetrock Gypsum Vinyl Yes No No Fair Yes Low NA Class A lay-in ceiling

National Gridstone Gypsum Vinyl Ltd. No No Fair Yes Low NA Class A Gypsum Cleanroom

Gridstone Gypsum Vinyl Ltd. No No Fair Yes Low NA Class A Cleanroom

CertainTeed Vinylshield C Gypsum Vinyl Ltd. No No Fair Yes Low NA Class A

Vinylshield C Gypsum Vinyl Ltd. No No Fair Yes Low NA Class A

Vinylshield C Gypsum Vinyl Ltd. No No Fair Yes Low NA Class A

Vinylshield C Gypsum Vinyl Ltd. No No Fair Yes Low NA Class A

ComparisonMatrix-ControlledEnvironmentFacilityCeilingPanels

USA and Canada: 800.323.7164 / fax: 800.222.3744 BarrierSystems 7chicagometallic.comPRODUCT

UPDATES

SpecificationData-BarrierPanProductinformationforintegrationintoceilingspecification

panel type I II III IV

FRP face with 1/2 gypsum bonded to 1 foam •

material aluminum skin bonded to honeycombed plastic core •

aluminum skin with HDPE core •

FRP skin with HDPE core •

surface smooth (high gloss) • • •

textured •

textured (high gloss) •

size 1-1/2: 2 x 2, 2 x 4 •

7/16: 2 x 2, 2 x 4 •

1/4: 2 x 2, 2 x 4 • •

edge square • • • •

indoor air quality 0 voc’s, 0 fiber release • • • •

fire class C • •

class A • •

insulation R = 4 •

classification ISO 14644 Class 5 • • • •

suspension 15/16, 1-3/8 • • • •

warranty one year limited • • • •

sustainability 75% recyclable, global manufacture

100% recyclable, global manufacture • • •

Productinformationforintegrationintoceilingspecification

suspension type BarrierGrid™ Premium - 1 3/8 BarrierGrid™ Standard - 15/16

material body HD Galvanized HD Galvanized

cap aluminum aluminum

angle painted aluminum painted aluminum

channel painted aluminum painted aluminum

size width 1 3/8 15/16

height 1 1/2 1 1/2

load rating ASTM 1 heavy duty heavy duty

seismic stab-type cross tees zones 3, 4 zones 3, 4 categories D, E, F categories D, E, F

warranty 40 year limited • •

sustainability Minimum 25% post consumer recycled content, 100% locally recyclable, global/regional manufacture • •1 Load rating calculated at L/360 per ASTM C-635.

SpecificationData-BarrierGrid

8 BarrierSystems chicagometallic.com

SpecificationStandard 15/16 BarrierGridPART 1 - GENERAL 1.01 Section Includes

Providemetalsuspensionsystemforlay-inacousticalpanelceiling.

1.02RelatedSections

A. Section 09 22 26 - Suspension Systems

B. Section 09 54 00 - Specialty Ceilings

C. Section 09 58 00 - Integrated Ceiling Assemblies

D. Section134800-Sound,Vibration,andSeismicControl

E. Section235000-CentralHeatingEquipment

F. Section 26 50 00 - Lighting

1.03References

A. AmericanSocietyforTestingandMaterials(ASTM)

1. C635 - Standard Specification for the manufacture, performance, and testing ofMetalSuspensionSystemsforAcousticalTileandLay-inPanelCeilings.

2. C636-StandardPracticeforInstallationofMetalCeilingSuspensionSystemsforAcousticalTileandLay-inPanels.

1.04 Submittals

A. Productdatasheetslistingdimensions,loadcarryingcapacityandstandardscompliance.

B. 12inchlongsamplesofMainTeesandCrossTeeswithintegralcouplings.

1.05ProjectConditions

A. EnvironmentalRequirements:

1. Verifyweathertightnessofareareceivingsuspensionsystempriortoinstal-lation.

2. Wettradesworktobethoroughlydryandcompletepriortoinstallation.

3. Installationtobeginonlywhentemperatureandhumidityconditionscloselyapproximateinteriorconditionswhichwillexistwhenareaiscompleteandoccupied.

4. Heating and air conditioning systems to be operating prior to, during, and after installation.

1.06Maintenance

Furnishadditionalmaterialequalto______percentofceilingarea.

PART 2 - PRODUCTS 2.01Manufacturers

ChicagoMetallic doublewebHeavydutynon-fire rated ceiling suspensionsystem.

2.02 Suspension System Components

A. MainTees:

1. Manufacturedfromcommercialquality0.020inchthickHDG-30steel,hot-dip galvanized steel, 15/16inchwideby11/2incheshighwithfactorypunchedcross tee slots, hanger holes, and integral bayonet-style end couplings.

2. Cappedwithaluminumcappingaffixedto15/16inchwideflange.

3. Coated with factory applied baked-on enamel paint from manufacturer’sstandard selection.

B. Cross Tees:

1. Manufacturedfromcommercialquality(0.010)(0.015)steel15/16inchwideby11/2inchhighby(24)(48)incheslongwithfactorypunchedcrossteeslots,hangerholes,and(Stab-in)(demountablehook)couplings.

2. Capped identical to main tees.

3. Finish identical to main tees.

C. GasketMaterial:

1. Gasketmustbemachineappliedwithin(.050)oftheedgeofthetee.Gasketmust have a 1/8 inch overhang on all cross tees.

2. GasketmaterialisaclosedcellPVCfoamandisconformabletobothsmoothandirregularsurfaces,sealingagainstwater,moisture,dirtandair-infiltrationwhencompressed30%.PVCfoamgasketresistsUVoxidation,mildewandfungus.

3. Gasketproperties includeelastomericconstruction,PVC foamsadjust tothermalmovementofmatingstructuralelementswithoutleakingandremainflexible.

4. Gasketingisdimensionallystableandwillnotdrip,ooze,orrunwhenundercompression. Gasket remains flexible at low temperatures, has excellentchemical resistance and forms an acoustic seal.

5. Gasketinghasanaveragedensityof8lb./cu.ft.andacompressiondeflectionof2psi(perASTMD-1667).

D. PerimeterTreatmentComponents:

1. AngleMoldings:Manufacturedfromcommercialqualitysteelwithaluminumcapped hemmed edges finished identical to main tees and cross tees.

2. ChannelMolding:Manufacturedfromcommercialqualitysteelwithaluminumcapped hemmed edges finished identical to main tees and cross tees.

PART 3 - EXECUTION 3.01 Examination

Examineareareceivingsuspensionsystemtoidentifyconditionswhichwilladverselyaffectinstallation.Donotbegininstallationuntiladverseconditionshave been remedied.

3.02 Installation

A. MainTees:Installed(36)(48)(60)(96)inchesoncenter,bydirectsuspensionfromexistingstructure,withnotlessthan12gagesteelhangerwires,wrappedtightly3 full turns, spaced (48)(60) inches on center along component length.

B. Cross Tees:

1. Installed perpendicular to main tees (12)(20)(24)(30)(48)(60)(72)(96)(120) inchesoncentertoform_______by_______modules.

2. Installed perpendicular to module forming cross tees (12)(20)(24)(30) inches oncentertoform_______by_______modules.

3. Installedadjacenttoeachunsupportedsideofrecessedfixtures.

C. (Angle)(Channel)Moldings:Installedonverticalsurfaces,intersectingsuspen-sioncomponentsbyappropriatemethodinaccordancewithindustryacceptedpractice.

D. AdditionalHangerWires:Wrappedtightly3fullturnstostructureandcompo-nentsatlocationswhereimposedloadscouldcausedeflectionexceeding1/360 span.

3.03Repair

A. Removedamagedcomponents,replacewithundamagedcomponents.Cleanwithnon-solventbasednon-abrasivecommercialcleaningsolution.

USA and Canada: 800.323.7164 / fax: 800.222.3744 BarrierSystems 9chicagometallic.comPRODUCT

UPDATES

Premium 1-3/8 BarrierGridPART 1 - GENERAL 1.01 Section Includes

Providemetalsuspensionsystemforlay-inacousticalpanelceiling.

1.02RelatedSections

A. Section 09 22 26 - Suspension Systems

B. Section 09 54 00 - Specialty Ceilings

C. Section 09 58 00 - Integrated Ceiling Assemblies

D. Section134800-Sound,Vibration,andSeismicControl

E. Section235000-CentralHeatingEquipment

F. Section 26 50 00 - Lighting

1.03References

A. AmericanSocietyforTestingandMaterials(ASTM)

1. C635 - Standard Specification for the manufacture, performance, and testing ofMetalSuspensionSystemsforAcousticalTileandLay-inPanelCeilings.

2. C636-StandardPracticeforInstallationofMetalCeilingSuspensionSystemsforAcousticalTileandLay-inPanels.

1.04 Submittals

A. Productdatasheetslistingdimensions,loadcarryingcapacityandstandardscompliance.

B. 12inchlongsamplesofMainTeesandCrossTeeswithintegralcouplings.

1.05ProjectConditions

A. EnvironmentalRequirements:

1. Verifyweathertightnessofareareceivingsuspensionsystempriortoinstal-lation.

2. Wettradesworktobethoroughlydryandcompletepriortoinstallation.

3. Installationtobeginonlywhentemperatureandhumidityconditionscloselyapproximateinteriorconditionswhichwillexistwhenareaiscompleteandoccupied.

4. Heating and air conditioning systems to be operating prior to, during, and after installation.

1.06Maintenance

Furnishadditionalmaterialequalto______percentofceilingarea.

PART 2 - PRODUCTS 2.01Manufacturers

Chicago Metallic double web Heavy duty non-fire rated ceiling suspensionsystem.

2.02 Suspension System Components

A. MainTees:

1. Manufacturedfromcommercialquality0.020inchthickHDG-30steel,hot-dipgalvanized steel, 13/8inchwideby11/2incheshighwithfactorypunchedcrosstee slots, hanger holes, and integral bayonet-style end couplings.

2. Cappedwithaluminumcappingaffixedto13/8inchwideflange.

3. Coated with factory applied baked-on enamel paint from manufacturer’sstandard selection.

B. Cross Tees:

1. Manufacturedfromcommercialquality(0.010)(0.015)steel13/8inchwideby11/2inchhighby(24)(48)incheslongwithfactorypunchedcrossteeslots,hanger holes, and Stab-in couplings.

2. Capped identical to main tees.

3. Finish identical to main tees.

C. GasketMaterial:

1. Gasketmustbemachineappliedwithin(.050)oftheedgeofthetee.Gasketmust have a 1/8 inch overhang on all cross tees.

2. GasketmaterialisaclosedcellPVCfoamandisconformabletobothsmoothandirregularsurfaces,sealingagainstwater,moisture,dirtandair-infiltrationwhencompressed30%.PVCfoamgasketresistsUVoxidation,mildewandfungus.

3. Gasketproperties includeelastomericconstruction,PVC foamsadjust tothermalmovementofmatingstructuralelementswithoutleakingandremainflexible.

4. Gasketingisdimensionallystableandwillnotdrip,ooze,orrunwhenundercompression. Gasket remains flexible at low temperatures, has excellentchemical resistance and forms an acoustic seal.

5. Gasketinghasanaveragedensityof8lb./cu.ft.andacompressiondeflectionof2psi(perASTMD-1667).

D. PerimeterTreatmentComponents:

1. AngleMoldings:Manufacturedfromcommercialqualitysteelwithaluminumcapped hemmed edges finished identical to main tees and cross tees.

2. ChannelMolding:Manufacturedfromcommercialqualitysteelwithaluminumcapped hemmed edges finished identical to main tees and cross tees.

PART 3 - EXECUTION 3.01 Examination

Examineareareceivingsuspensionsystemtoidentifyconditionswhichwilladverselyaffectinstallation.Donotbegininstallationuntiladverseconditionshave been remedied.

3.02 Installation

A. MainTees:Installed(36)(48)(60)(96)inchesoncenter,bydirectsuspensionfromexistingstructure,withnotlessthan12gagesteelhangerwires,wrappedtightly3 full turns, spaced (48)(60) inches on center along component length.

B. Cross Tees:

1. Installed perpendicular to main tees (12)(20)(24)(30)(48)(60)(72)(96)(120) inchesoncentertoform_______by_______modules.

2. Installed perpendicular to module forming cross tees (12)(20)(24)(30) inches oncentertoform_______by_______modules.

3. Installedadjacenttoeachunsupportedsideofrecessedfixtures.

C. (Angle)(Channel)Moldings:Installedonverticalsurfaces,intersectingsuspen-sioncomponentsbyappropriatemethodinaccordancewithindustryacceptedpractice.

D. AdditionalHangerWires:Wrappedtightly3fullturnstostructureandcompo-nentsatlocationswhereimposedloadscouldcausedeflectionexceeding1/360 span.

E. HEPAFiltersandlightfixturesmustbesupportedby4hangerwires.Oneoneach corner of the fixture.

3.03Repair

A. Removedamagedcomponents,replacewithundamagedcomponents.Cleanwithnon-solventbasednon-abrasivecommercialcleaningsolution.

Specification

10 BarrierSystems chicagometallic.com

SpecificationBarrierPan IPART 1 - GENERAL1.01 ScopeFurnishandinstallBarrierPanIFRPfacedwith1/2 inch gypsum bonded to 1 inch foamceilingpanelsbyChicagoMetallicCorporation.

1.02ReferencesA. Section 09120 Ceiling Suspension Systems

B. Section09250GypsumBoard

C. Section 09545 Special Ceiling Surfaces

D. Section13020IntegratedAssemblies

E. Section 13080 Sound, Vibration, and Seismic Control

F. Section 15550 Heating, Ventilating, and Air Conditioning

G. Section16500Lighting

1.03 StandardsA. AmericanSocietyforTestingandMaterials(ASTM)

1. C635MetalSuspensionSystemsforAcousticalTileandLay-InPanelCeilings.

2. C636InstallationofMetalCeilingSuspensionSystems.

3. E 84 Surface Burning Characteristics.

1.04 SubmittalsA. Product data: Manufacturers standard data sheets listing dimensions and

details.

B. Samples:Manufacturersstandardsamplesincludingsuspension,panelsandcolors.

C. ShopDrawings:Reflectedceilingplanandelevationdrawingsindicatingceilinglayouts, dimensions and perimeter conditions.

1.04ProjectConditionsA. EnvironmentalRequirements

1. Verifyweathertightnessofareapriortoinstallation.

2. Wettradesworktobethoroughlydryandcompletepriortoinstallation.

3. Delivermaterials inmanufacturersoriginalpackaging,unopenedandundamaged.

4. Store materials in an enclosed dry location at room temperature and protect from soiling, damage, direct sunlight, moisture and humidity.

1.08 MaintenanceA. Furnishadditionalmaterialequalto[___]%oftheceilingsystemarea.

PART 2 - PRODUCTS2.01ManufacturerA. BarrierPanIFRPfacedwith1/2 inch gypsum bonded to 1 inch foam ceiling

panelsbyChicagoMetallicCorporation,4849S.AustinAvenue,Chicago,IL60638-1492.Phone:800.323.7164or708.563.4600. Web:chicagometallic.com.

2.02MaterialsA. Panels:BarrierPanIFRPfacedwith1/2 inch gypsum bonded to 1 inch foam

ceilingpanelstolayinto[15/16inch][13/8inch]T-bargasketedgrid.

B. Material:firecodegypsumboard.

C. Surface:USDAaccepted2millaminatedfiberglassreinforcedplastic(textured)(smooth) face.

D. NominalSize:(11/2 inch x 24 inch x 24 inch)(11/2 inch x 24 inch x 48 inch).

E. Edge:square.

F. Indoor Air Quality: voc not established, 0 fiber release.

G. Fire:ClassC perASTME84.

H. Classificationtype:typeXX,patternGperASTME1264.

I. Warranty:1yearlimited.

J. Sustainability:75%recycledcontentbyweight.

PART 3 - EXECUTION3.01 ExaminationA. Examineareareceivingsystemtoidentifyconditionswhichwilladverselyaf-

fectinstallation.Donotbegininstallationuntiladverseconditionshavebeenremedied.

3.02 InstallationA. Refertomanufacturer’swritteninstallationinstructions.

B. Installlayinacousticalceilingpanelsflushandlevelinsuspensionsystem.

C. Installpanelswithhandprotectiontoavoidsoiling.

D. Presspanelsfromabovetosetintogrids.Donotpullfromface.

E. Handle components to prevent damage.

F. Cleanadjacentsurfacesandremoveunusedproductanddebrisfromsite.

G. Afterinstallationiscompleted,cleansoiledsurfacesofmaterials.

H. Removeandreinstallimproperlyinstalledmaterial.

I. Removedamagedordiscoloredmaterial,ormaterialthatcannotbeproperlycleaned,andinstallnewmaterial.

BarrierPan IIPART 1 - GENERAL1.01 ScopeFurnishandinstallBarrierPanIIdoublefacealuminumwithhoneycombedplasticcoreceilingpanelsbyChicagoMetallicCorporation.

1.02References

A. Section 09120 Ceiling Suspension Systems

B. Section09250GypsumBoard

C. Section 09545 Special Ceiling Surfaces

D. Section13020IntegratedAssemblies

E. Section 13080 Sound, Vibration, and Seismic Control

F. Section 15550 Heating, Ventilating, and Air Conditioning

G. Section16500Lighting

1.03 StandardsA. AmericanSocietyforTestingandMaterials(ASTM)

1. C635MetalSuspensionSystemsforAcousticalTileandLay-InPanelCeilings.

2. C636InstallationofMetalCeilingSuspensionSystems.

3. E 84 Surface Burning Characteristics.

1.04 SubmittalsA. Product data: Manufacturers standard data sheets listing dimensions and

details.

B. Samples:Manufacturersstandardsamplesincludingsuspension,panelsandcolors.

C. ShopDrawings:Reflectedceilingplanandelevationdrawingsindicatingceilinglayouts, dimensions and perimeter conditions.

1.04ProjectConditionsA. EnvironmentalRequirements

1. Verifyweathertightnessofareapriortoinstallation.

2. Wettradesworktobethoroughlydryandcompletepriortoinstallation.

3. Delivermaterials inmanufacturersoriginalpackaging,unopenedandundamaged.

4. Store materials in an enclosed dry location at room temperature and protect from soiling, damage, direct sunlight, moisture and humidity.

1.08MaintenanceA. Furnishadditionalmaterialequalto[___]%oftheceilingsystemarea.

PART 2 - PRODUCTS2.01ManufacturerA. BarrierPan II double facealuminumwithhoneycombedplastic core ceiling

panelsbyChicagoMetallicCorporation,4849S.AustinAvenue,Chicago,IL60638-1492 Phone: 800.323.7164 or 708.563.4600. Web: chicagometallic.com.

2.02MaterialsA. Panels:BarrierPanIIdoublefacealuminumwithhoneycombedplasticcore

ceilingpanelstolayinto[15/16inch][13/8inch]T-bargasketedgrid.

B. Material:firecodegypsumboard.

C. Surface:USDAaccepted2millaminatedaluminumface.

D. NominalSize:(7/16 inch x 24 inch x 24 inch)(7/16 inch x 24 inch x 48 inch).

E. Edge:square.

F. Indoor Air Quality: voc not established, 0 fiber release.

G. Fire:ClassA perASTME84.

H. Classification type: ISO 14644 Class 5.

I. Warranty:1yearlimited.

J. Sustainability:100%recycledcontentbyweight.

PART 3 - EXECUTION3.01 ExaminationA. Examineareareceivingsystemtoidentifyconditionswhichwilladverselyaf-

fectinstallation.Donotbegininstallationuntiladverseconditionshavebeenremedied.

3.02 InstallationA. Refertomanufacturer’swritteninstallationinstructions.

B. Installlayinacousticalceilingpanelsflushandlevelinsuspensionsystem.

C. Installpanelswithhandprotectiontoavoidsoiling.

D. Presspanelsfromabovetosetintogrids.Donotpullfromface.

E. Handle components to prevent damage.

F. Cleanadjacentsurfacesandremoveunusedproductanddebrisfromsite.

G. Afterinstallationiscompleted,cleansoiledsurfacesofmaterials.

H. Removeandreinstallimproperlyinstalledmaterial.

I. Removedamagedordiscoloredmaterial,ormaterialthatcannotbeproperlycleaned,andinstallnewmaterial.

USA and Canada: 800.323.7164 / fax: 800.222.3744 BarrierSystems 11chicagometallic.comPRODUCT

UPDATES

SpecificationBarrierPan IIIPART 1 - GENERAL1.01 ScopeFurnishandinstallBarrierPanIIIdoublefacealuminumwithHDPEcoreceilingpanelsbyChicagoMetallicCorporation.

1.02ReferencesA. Section 09120 Ceiling Suspension Systems

B. Section09250GypsumBoard

C. Section 09545 Special Ceiling Surfaces

D. Section13020IntegratedAssemblies

E. Section 13080 Sound, Vibration, and Seismic Control

F. Section 15550 Heating, Ventilating, and Air Conditioning

G. Section16500Lighting

1.03 StandardsA. AmericanSocietyforTestingandMaterials(ASTM)

1. C635MetalSuspensionSystemsforAcousticalTileandLay-InPanelCeilings.

2. C636InstallationofMetalCeilingSuspensionSystems.

3. E 84 Surface Burning Characteristics.

1.04 SubmittalsA. Product data: Manufacturers standard data sheets listing dimensions and

details.

B. Samples:Manufacturersstandardsamplesincludingsuspension,panelsandcolors.

C. ShopDrawings:Reflectedceilingplanandelevationdrawingsindicatingceilinglayouts, dimensions and perimeter conditions.

1.04ProjectConditionsA. EnvironmentalRequirements

1. Verifyweathertightnessofareapriortoinstallation.

2. Wettradesworktobethoroughlydryandcompletepriortoinstallation.

3. Delivermaterials inmanufacturersoriginalpackaging,unopenedandundamaged.

4. Store materials in an enclosed dry location at room temperature and protect from soiling, damage, direct sunlight, moisture and humidity.

1.08MaintenanceA. Furnishadditionalmaterialequalto[___]%oftheceilingsystemarea.

PART 2 - PRODUCTS2.01ManufacturerA. BarrierPanIIIdoublefacealuminumwithHDPEcoreceilingpanelsbyChi-

cago Metallic Corporation, 4849 South Austin Avenue, Chicago, IL 60638-1492.Phone:800.323.7164or708.563.4600. Web:chicagometallic.com.

2.02MaterialsA. Panels:BarrierPanIIIdoublefacealuminumwithHDPEcoreceilingpanelsto

layinto[15/16inch][13/8inch]T-bargasketedgrid.

B. Material:firecodegypsumboard.

C. Surface:USDAacceptedaluminumface.

D. NominalSize:(1/4 inch x 24 inch x 24 inch)(1/4 inch x 24 inch x 48 inch).

E. Edge:square.

F. Indoor Air Quality: voc not established, 0 fiber release.

G. Fire:ClassA perASTME84.

H. Classification type: ISO 14644 Class 5.

I. Warranty:1yearlimited.

J. Sustainability:100%recycledcontentbyweight.

PART 3 - EXECUTION3.01 ExaminationA. Examineareareceivingsystemtoidentifyconditionswhichwilladverselyaf-

fectinstallation.Donotbegininstallationuntiladverseconditionshavebeenremedied.

3.02 InstallationA. Refertomanufacturer’swritteninstallationinstructions.

B. Installlayinacousticalceilingpanelsflushandlevelinsuspensionsystem.

C. Installpanelswithhandprotectiontoavoidsoiling.

D. Presspanelsfromabovetosetintogrids.Donotpullfromface.

E. Handle components to prevent damage.

F. Cleanadjacentsurfacesandremoveunusedproductanddebrisfromsite.

G. Afterinstallationiscompleted,cleansoiledsurfacesofmaterials.

H. Removeandreinstallimproperlyinstalledmaterial.

I. Removedamagedordiscoloredmaterial,ormaterialthatcannotbeproperlycleaned,andinstallnewmaterial.

BarrierPan IVPART 1 - GENERAL1.01 ScopeFurnishandinstallBarrierPanIVdoublefaceFRPwithHDPEcoreceilingpanelsbyChicagoMetallicCorporation.

1.02ReferencesA. Section 09120 Ceiling Suspension Systems

B. Section09250GypsumBoard

C. Section 09545 Special Ceiling Surfaces

D. Section13020IntegratedAssemblies

E. Section 13080 Sound, Vibration, and Seismic Control

F. Section 15550 Heating, Ventilating, and Air Conditioning

G. Section16500Lighting

1.03 StandardsA. AmericanSocietyforTestingandMaterials(ASTM)

1. C635MetalSuspensionSystemsforAcousticalTileandLay-InPanelCeilings.

2. C636InstallationofMetalCeilingSuspensionSystems.

3. E 84 Surface Burning Characteristics.

1.04 SubmittalsA. Product data: Manufacturers standard data sheets listing dimensions and

details.

B. Samples:Manufacturersstandardsamplesincludingsuspension,panelsandcolors.

C. ShopDrawings:Reflectedceilingplanandelevationdrawingsindicatingceilinglayouts, dimensions and perimeter conditions.

1.04ProjectConditionsA. EnvironmentalRequirements

1. Verifyweathertightnessofareapriortoinstallation.

2. Wettradesworktobethoroughlydryandcompletepriortoinstallation.

3. Delivermaterials inmanufacturersoriginalpackaging,unopenedandundamaged.

4. Store materials in an enclosed dry location at room temperature and protect from soiling, damage, direct sunlight, moisture and humidity.

1.08MaintenanceA. Furnishadditionalmaterialequalto[___]%oftheceilingsystemarea.

PART 2 - PRODUCTS2.01ManufacturerA. BarrierPan IVdouble faceFRPwithHDPEcoreceilingpanelsbyChicago

Metallic Corporation, 4849 South Austin Avenue, Chicago, IL 60638-1492.Phone:800.323.7164or708.563.4600. Web:chicagometallic.com

2.02MaterialsA. Panels:BarrierPanIVdoublefaceFRPwithHDPEcoreceilingpanelstolay

into[15/16inch][1-3/8inch]t-bargasketedgrid.

B. Material:firecodegypsumboard.

C. Surface:USDAaccepted2milFRPface.

D. NominalSize:(1/4inchx24inchx24inch)(1/4inchx24inchx48inch).

E. Edge:square.

F. Indoor Air Quality: voc not established, 0 fiber release.

G. Fire:ClassC perASTME84.

H. Classification type: ISO 14644 Class 5.

I. Warranty:1yearlimited.

J. Sustainability:100%recycledcontentbyweight.

PART 3 - EXECUTION3.01 ExaminationA. Examineareareceivingsystemtoidentifyconditionswhichwilladverselyaf-

fectinstallation.Donotbegininstallationuntiladverseconditionshavebeenremedied.

3.02 InstallationA. Refertomanufacturer’swritteninstallationinstructions.

B. Installlayinacousticalceilingpanelsflushandlevelinsuspensionsystem.

C. Installpanelswithhandprotectiontoavoidsoiling.

D. Presspanelsfromabovetosetintogrids.Donotpullfromface.

E. Handle components to prevent damage.

F. Cleanadjacentsurfacesandremoveunusedproductanddebrisfromsite.

G. Afterinstallationiscompleted,cleansoiledsurfacesofmaterials.

H. Removeandreinstallimproperlyinstalledmaterial.

I. Removedamagedordiscoloredmaterial,ormaterialthatcannotbeproperlycleaned,andinstallnewmaterial.

Literature Disclaimer: Presentations in this brochure or any other Chicago Metallic Corporation publication are correct to the best of our knowledge at time of preparation. We provide this information in an advisory capacity only. Any advisory recommendations given in our publications must be modified to conform with local codes, conditions and specifications. We reserve all rights to amend any information published in our literature without additional notice. Chicago Metallic can not be held responsible or liable for the selection nor application of our products.

CeilingSystemsandSpecialtyProducts-USAandCanada:800.323.7164/Fax:800.222.3744/www.chicagometallic.combelgium / denmark / uk / germany / france / hong kong / prc / malaysia / united arab emirates / mexico

ChicagoMetallicanditslogoareRegisteredTrademarksofChicagoMetallicCorporation.BarrierGridandBarrierPanaretrademarksofChicagoMetallicCorporation.©2011ChicagoMetallicCorporation AllRightsReserved PrintedinUSA SNL0164B2111

GeneralConditionsofSaleOrder AcceptanceWhenever used herein, “Seller” shall refer to Chicago Metallic Corporation and“Purchaser”shallrefertothepartyorderingorpurchasingproducts(“Products”)fromSeller.Seller’spricelistdoesnotconstituteanoffertosellProductslistedtherein,but issimplyprovidedasaconveniencetoprospectivePurchasers.Purchaser’sordertoSellershallconstituteanoffertoSellertopurchaseProductswhichofferSellermayacceptatitssolediscretion.AcceptanceshallbebyawritingcontainingtheseGeneralConditionsofSale(“Conditions”).AcceptanceofPurchaser’sorderoranypartofitbySellerisexpresslymadeconditionalonPurchaser’sassenttotheseConditions.PurchasermayvarytheseConditionsonlywiththewrittenconsentofSeller.AcceptanceofProductsbyPurchaserorfailureofPurchasertoobjectinwritingtotheseConditionswithinten(10)daysfollowingdeliveryofProductstoPurchasershallconstitutePurchaser’sassenttotheseConditions.

Shipment and DeliverySellershalldeliverProductF.O.B.placeofshipment.RiskoflosstoProductshallpass to Purchaser upon delivery to carrier at such place of shipment. CarrieractsasPurchaser’sagent.Productsshallbeshippedassoonaspractical,orasrequestedbyPurchaserafterorderacceptancebySeller.However,deliverydatesshallnotbeoftheessence,butshallberegardedasSeller’sbestapproximationofsuchdeliverydates.SellermayarrangefreightattherequestofandonbehalfofPurchaser.Ifapplicable,freightwillbechargedaccordingtotheSeller’sfreightpolicyineffectattimeofshipment.SuchpolicywillbeprovidedtoPurchaserviaitspreferredcommunicationmethodandisalsoavailableinSeller’spricebookoruponrequest.Alltaxes,tariffs,dutiesorsimilarchargespaidbySellerimposedorleviedbyanygovernmentalauthorityinconnectionwiththepurchase,shipment,importorexportofProductspurchasedorinconnectionwiththeprocuringofmaterialsusedthereinmayatSeller’ssoleoptionbeaddedtothepriceofProductssoaf-fected.AdditionalshippingchargesforProductspaidbySellersuchasdestination,storage, labor and redelivery and special or extra expenses for handling air freight, busorothershipmentsmayalso,atSeller’ssoleoption,beaddedtothepriceofsuchProducts.

PaymentPaymentforallProductsshallbenetcashdueandpayableinU.S.dollarswithinthirty(30)daysfollowingreceiptbyPurchaserofshippingdocumentsforsuchProductsbycheckorbanktransfertoabankaccounttobedesignatedbySeller.Ifaccountsarepaidwithinten(10)daysfollowingreceiptbyPurchaserofthecorrespondingshippingdocuments,Purchasershallbeenentitledtoaonepercent(1%)discountfromthepriceofProductsonly.If,inSeller’ssoleopinion,thefinancialconditionofthePurchasersowarrants,Sellermayrequireadvancepaymentsorsatisfactorysecurity.IntheeventthatthePurchaserfailstomakesuchadvancepaymentsorfurnishsuchsecurityuponSeller’srequest,deliveryofProductsmaybesuspendedwithoutfurtherSellerobligation.Sellermay,atSeller’ssoleoption,requirepaymentbymeansofanirrevocableletterofcreditopenedandconfirmedbyabankorbanksacceptable to Seller and upon terms and conditions acceptable to Seller.

Limited WarrantySellerwarrants toPurchaser thatProductswillsubstantiallyconform inquantityandqualitytoPurchaser’sorder,asacceptedbySeller,provided,however,that(1)ProductsareinspectedbyPurchaseruponarrivalatplaceofdestinationandanyandall nonconformities are noted on the bill of lading and all other delivery documents andareattestedto inwritingbycarrier’srepresentative(2)PurchaserfurnishesSellerwithwrittennoticeofsuchnon-conformitieswithinfifteen(15)daysfollowingarrivalofnon-conformingProductsattheplaceofdestination,(3)PurchaserholdsnonconformingProductsforSeller’sinspection(4)non-conformitiesoccurredpriortodeliverybySellerofProductsF.O.B.placeofshipment,and(5)Purchaserdoesnotalter,repair,useorattempttoalterorrepairanynon-conformingProducts.ThislimitedwarrantyisSeller’sonlyandexclusiveexpresswarrantytoPurchaser.Sellerdisclaimsanyandall impliedwarranties includingwithout limitationany impliedwarrantyofmerchantabilityorfitnessforaparticularpurpose.Purchaser’ssoleand

exclusive remedy against Seller shall be the replacement F.O.B. its plant or site, at Seller’soption,ofanyProductswhichdonotconformtoSeller’slimitedwarrantyhereunder.Nootherremedy(including,withoutlimitation,incidentalorconsequen-tialdamagesforlostprofits,lostsales,injurytopersonsorpropertyoranyotherincidentalorconsequentialloss)shallbeavailabletoPurchaser.PurchaseragreestoincludeinallcontractsbetweenPurchaserandsubsequentownersorusersofProducts,andtobringtotheattentionofallPurchaser’scustomersofProducts,thefollowingwarrantydisclaimer:ChicagoMetallicCorporationdisclaimsanyandallwarrantiesexpressedorimplied,including,withoutlimitation,anyimpliedwarrantyofmerchantabilityorfitnessforaparticularpurpose.PurchasershallbeexcludedonbehalfofSellerallremediesfordamageorinjurytoProductspersonsorproperty.IntheeventthatPurchaserfailstocomplywiththeforegoingobligations,Purchasershall indemnify Seller for any liability resulting from such non-compliance and shall otherwiseholdSellerharmless.

ReturnsInordertoreturnanyProductstoSeller,Purchasermustfirstobtainpriorauthorizationforproductseligibleforreturn,andreceiveaReturnGoodsAuthorizationnumberfromSeller’shomeoffice.Allauthorizedreturnsaresubjecttoa20%restockingcharge.SellerwillonlyissuecreditforServiceLevel“0”materialreceivedatthedesignated company facility with the Return Goods Authorization appearing onthe material, and after being inspected and determined by Seller to be in resalable condition.Purchaserissolelyresponsibleforarrangingandprepayingforallreturnfreight.Sellerwillnotberesponsibleforanydamageintransitonmaterialreturnedatcustomer’srequest,andwillnotfilefreightclaimsonsuchdamagedmaterial.When these termsaremet,sellerwill issueappropriatematerialcredit less therestockingcharge.

Default, Termination and Suspension of DeliverySellerreservestheright,amongotherremedies,eithertocancelPurchaser’sorderorsuspendfurtherdeliveriesofProductsthereunderintheeventthat(1)Purchaserfails topay foranyoneshipmentofProductswhenpayment forsuchshipmentbecomesdue;(2)PurchaserfailstomakeanyadvancepaymentsorsatisfactorysecuritydemandedbySellerpursuanttoparagraphtwoofPAYMENTSsectionabove;or(3)PurchaserfailsorrefusestoacceptanydeliveryofProductsorderedfromSeller.DeliveryofProductsmaybesuspendedinwholeorinpartincaseofanyeventbeyondSeller’scontrol,including,butnotlimitedto,explosion,fire,shortageoffuel,powerorrawmaterialsfloodstrikelockout,injunction,riot,insurrection,war,nationalemergency,governmentact,oractofGod.

MiscellaneousNofailureordelayonthepartofSellerinexercisinganyright,powerorprivilegehereundershalloperateasawaiverthereoforofanyotherright,powerorprivilegehereundernorshallanysingleorpartialexerciseofanysuchrightpowerorprivilegeprecludeanyotherright,powerorprivilege.TherightsorremediesofSellerhereunderarecumulativeandnotexclusiveofanyrightsorremedieswhichitmayotherwisehave.Thepartiesheretomaycorrectstenographicandclericalerrorswithout li-ability.PurchasermaynotassigntheorderwithouttheexpresswrittenconsentofSeller. All notices to be given hereunder by either party to the other party shall be dispatchedbycertifiedorregisteredmailreturnreceiptrequestedaddressedtothelastknownpostofficeaddressofsuchotherparty.Anysuchnoticeshallbedeemedreceivedwithinfive(5)daysfollowinganysuchdispatchifmailedfromwithintheUnited States of America and ten (10) days if mailed from outside the United States of America. Either party may change its address by notice to the other party. These ConditionsshallbegovernedbyandinterpretedinaccordancewiththelawsoftheState of Illinois, United States of America, and all disputes hereunder that cannot be amicably resolved by the parties thereto must be settled in a court of competent jurisdictionwithintheStateofIllinois,UnitedStatesofAmerica.Theprovisionsofthese Conditions shall be severable one from the other so that should any provision beheldlegallyunenforceablebyacourtofcompetentjurisdiction,theremainingprovisions shall remain in effect.