![Page 1: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/1.jpg)
Backdrafting Overblown! Rethinking Combustion Appliance Safety
February 26, 2014 RESNET, Atlanta, GA
Brett Singer & Vi Rapp [email protected] [email protected]
![Page 2: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/2.jpg)
Why do we conduct combustion safety tests?
Singer & Rapp 2 Feb 26, 2014
What are we worried about?
What are we trying to prevent?
![Page 3: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/3.jpg)
What are the most severe combustion appliance hazards?
Singer & Rapp 3 Feb 26, 2014
What are the most common combustion appliance hazards?
![Page 4: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/4.jpg)
What level of health risk are we willing to tolerate?
Singer & Rapp 4 Feb 26, 2014
![Page 5: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/5.jpg)
Key Point: Objectives
Critical: Identify appliances and venting systems that are broken or likely to break.
Critical: Identify gas leaks and other life-safety hazards.
Important: Identify appliances that cannot reliably establish draft under conditions that are likely to be encountered.
Feb 26, 2014 Singer & Rapp 5
![Page 6: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/6.jpg)
Natural draft appliance + airtight home
Source: Moore, Rich (2011). CAZ Pressure Testing. ACI Presentation, March, Denver, CO.
Death by Carbon
Monoxide
Feb 26, 2014 Singer & Rapp 6
= DANGER
IS THIS TRUE?
![Page 7: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/7.jpg)
Engine Driven Tools
49%
Furnaces 14%
Other Heating Systems
17%
Water Heaters
2%
Ranges and Ovens
2% Multiple Products
8%
Other 8%
Reality: more deaths by lightning than by furnace or water heater CO
Source: Hnatov, M.V., Non-Fire Carbon Monoxide Deaths Associated with the Use of consumer
Products: 2007 Annual Estimates (2011)
2002-2011 average:37 deaths / year from lightning
(NOAA)
< 32 deaths / year from water heaters
and furnaces
U.S. average 2005-2007: 184 deaths / year from unintentional CO poisoning
Feb 26, 2014 Singer & Rapp 7
![Page 8: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/8.jpg)
Health hazards associated with combustion appliances
Singer & Rapp 8 Feb 26, 2014
Life-Safety CO at level that impairs judgment, creates risk of more severe effects including death (100+ ppm CO)
Acute Impacts sensitive individuals when CO & NO2 exceed outdoor air quality standards
(10-50 ppm CO; 100-200 ppb NO2)
Chronic Low-level exposures over periods of weeks or more (5-10 ppm CO)
![Page 9: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/9.jpg)
Acute ambient CO levels that could result in hospitalization or death
Ambient Concentration Exposure Symptoms
100 ppm 2-3 hours Slight Headache 200 ppm 2-3 hours Headache, Nausea 400 ppm 2-3 hours Life threatening 800 ppm 2 hours Death
Feb 26, 2014 Singer & Rapp 9
GOLDSTEIN,M.Carbonmonoxidepoisoning.JournalofEmergencyNursing34,6(December2008), 538–542.
![Page 10: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/10.jpg)
CO standards to protect sensitive sub-populations of general population
Organization 1 hour average (ppm)
8 hour average (ppm)
National Ambient Air Quality Stds
35 9
California Ambient Air Quality Stds
20 9
Health Canada 25 10** Consumer Product Safety Commission
25 15
** 24 hour time-weighted average
Feb 26, 2014 Singer & Rapp 10
![Page 11: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/11.jpg)
Health hazards associated with combustion appliances
Singer & Rapp 11 Feb 26, 2014
Life-Safety: Must NEVER happen Requires extreme failure of burner and venting; not just depressurization-induced spillage
Acute: Costly to eliminate; must manage Sustained spillage + problem with combustion
Chronic: Minimal risk achievable Requires routine spillage + compromised combustion Moisture can can still be a problem even if CO low
![Page 12: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/12.jpg)
What are the practiced procedures?
Singer & Rapp 12 Feb 26, 2014
Visual inspection
http://blog.greenhomesamerica.com/2009/12/22/dont-mess-around-with-appliance-venting/
![Page 13: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/13.jpg)
Singer & Rapp 13 Feb 26, 2014
Visual inspection
Spillage Test
http://www.metrohome.us/
What are the practiced procedures?
![Page 14: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/14.jpg)
Singer & Rapp 14 Feb 26, 2014
Visual inspection
Spillage Test
Flue CO Test
http://www.htownhomeinspector.com/node/56 http://www.plumbtechnj.com/wp-content/uploads/2012/09/Carbon-monoxide-awareness.jpg
What are the practiced procedures?
![Page 15: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/15.jpg)
What are the practiced procedures?
Singer & Rapp 15 Feb 26, 2014
Visual inspection
Spillage Test
Flue CO Test
Worst-case Depressurization
![Page 16: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/16.jpg)
What are the practiced procedures?
Singer & Rapp 16 Feb 26, 2014
Visual inspection
Spillage Test
Flue CO Test
Worst-case Depressurization
What do the results mean?
![Page 17: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/17.jpg)
Backdraft Intro: consider a 6 ACH50 house with a natural draft furnace…
Dp = Po - Pin < 1 Pa
Feb 26, 2014 Singer & Rapp 17
![Page 18: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/18.jpg)
Operate a 375 cfm range hood… No problem
Dp = Po - Pin = 4 Pa
Feb 26, 2014 Singer & Rapp 18
![Page 19: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/19.jpg)
Air-seal to 4 ACH50 and you are likely to fail a combustion safety test
Assumed backdraft + spillage Depressurization
Dp = Po - Pin = 7 Pa
Feb 26, 2014 Singer & Rapp 19
![Page 20: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/20.jpg)
Is this really a problem?
Assumed backdraft + spillage Depressurization
Dp = Po - Pin = 7 Pa
Feb 26, 2014 Singer & Rapp 20
![Page 21: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/21.jpg)
What determines if there is a problem?
Feb 26, 2014 Singer & Rapp 21
Is appliance really not able to establish draft at -7 Pa?
How often is there 375 cfm of exhaust with burner on?
Does spillage occur long enough to create a hazard?
How does exhaust flow impact buildup of exhaust gases and pollutants?
![Page 22: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/22.jpg)
Combustion hazards depend on both physics and statistics
Feb 26, 2014 Singer & Rapp 22
Is appliance really not able to establish draft at -7 Pa? Vent configuration Atmospheric conditions
How often is there 375 cfm of exhaust with burner on?
Does spillage occur long enough to create a hazard?
How does exhaust flow impact buildup of exhaust gases and pollutants? How much CO emitted?
![Page 23: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/23.jpg)
Worst-Case Depressurization Test
Threshold Test: Compare to depressurization limit
Draft Test: Does the appliance draft under WCD?
Feb 26, 2014 Singer & Rapp 23
![Page 24: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/24.jpg)
Depressurization limits BPI RESNET
Feb 26, 2014 Singer & Rapp 24
Orphan natural draft water heater -2 Pa
Natural draft boiler or furnace commonly vented with water heater -3 Pa
Individual natural draft boiler or furnace Induced draft boiler Furnace commonly vented with a water heater
-5 Pa
Power vented or induced draft boiler or furnace along, or fan assisted DHW alone -15 Pa
Atmospheric vented oil or gas system -5 Pa
Pellet stoves with exhaust fans and sealed vents -15 Pa
![Page 25: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/25.jpg)
What is the basis of these limits? BPI RESNET
Feb 26, 2014 Singer & Rapp 25
Orphan natural draft water heater -2 Pa
Natural draft boiler or furnace commonly vented with water heater -3 Pa
Individual natural draft boiler or furnace Induced draft boiler Furnace commonly vented with a water heater
-5 Pa
Power vented or induced draft boiler or furnace alone, or fan assisted DHW alone -15 Pa
Atmospheric vented oil or gas system -5 Pa
Pellet stoves with exhaust fans and sealed vents -15 Pa
![Page 26: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/26.jpg)
The physics of draft
Da Dt ΔΔpLoss Dp
Theoretical Draft
Flow Losses
Depressurization
Depressurization just one part of the equation
Feb 26, 2014 Singer & Rapp 26
2008 ASHRAE Handbook – HVAC Systems and Equipment, Chapter 34
Available Draft
![Page 27: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/27.jpg)
The physics of drafting
Da Dt ΔΔpLoss Dp Burner
Size
Appliance Efficiency
Vent Dimension
Weather
Feb 26, 2014 Singer & Rapp 27
Depressurization just one part of the equation
![Page 28: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/28.jpg)
Theoretical draft
Da Dt ΔΔpLoss Dp Burner
Size
Appliance Efficiency
Vent Dimension
Weather
Heat Output Rate
Feb 26, 2014 Singer & Rapp 28
![Page 29: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/29.jpg)
Theoretical draft
Da Dt ΔΔpLoss Dp Burner
Size
Appliance Efficiency
Vent Dimension
Weather
Buoyancy
Feb 26, 2014 Singer & Rapp 29
![Page 30: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/30.jpg)
Friction losses in vent
Da Dt ΔΔpLoss Dp Vent
Design (Bends)
Bird Nest
Weather
Feb 26, 2014 Singer & Rapp 30
Vent Location &
Material
![Page 31: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/31.jpg)
Friction losses in vent
Da Dt ΔΔpLoss Dp
WH 40,000 Btu/hr
Furnace 125,000 Btu/hr
Vent Design (Bends)
Vent Location &
Material
Bird Nest
Weather
Feb 26, 2014 Singer & Rapp 31
![Page 32: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/32.jpg)
Friction losses in vent
Da Dt ΔΔpLoss Dp
Heat Loss
Vent Design (Bends)
Bird Nest
Weather
Vent Location &
Material
Feb 26, 2014 Singer & Rapp 32
![Page 33: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/33.jpg)
Depressurization
Da Dt ΔΔpLoss Dp Exhaust
Fans
CAZ Location
Envelope Tightness
Other Appliances
Usage Patterns
Weather Feb 26, 2014 Singer & Rapp 33
![Page 34: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/34.jpg)
Worst-Case Depressurization
Threshold Test: Compare to depressurization limit
Draft Test: Does the appliance draft under WCD?
Feb 26, 2014 Singer & Rapp 34
![Page 35: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/35.jpg)
CVEP is the maximum depressurization an appliance can overcome Cold Vent Establishment Pressure (CVEP)
1. Measure diff. pressure between CAZ and outdoors 2. Depressurize house using blower door 3. Turn on the appliance (should be spilling)* 4. Lower house depressurization until appliance
establishes draft 5. Record the differential pressure when the appliance
established draft *Measure downdraft CO at this point if not before
Feb 26, 2014 Singer & Rapp 35
![Page 36: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/36.jpg)
How much depressurization can water heaters overcome?
Singer & Rapp 36 Feb 26, 2014
0
2
4
6
8
10
12
14
16
18
20
0 20 40 60 80 100
CV
EP
(Pa)
Temperature (deg F)
Common Vented Stand Alone
70 water heaters Mean CVEP = 6.9 Pa 63% had CVEP > 5 Pa
Data taken from Koontz et al., 1999; Grimsrud and Hadlich, 1999
![Page 37: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/37.jpg)
How much depressurization can furnaces overcome?
Singer & Rapp 37 Feb 26, 2014
0
5
10
15
20
25
30
0 20 40 60 80 100
CVE
P (-P
a)
Temperature (deg F)
58 common vented furnaces Mean CVEP = 9.4 Pa 81% had CVEP > 5 Pa
Data taken from Koontz et al., 1999; Grimsrud and Hadlich, 1999
![Page 38: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/38.jpg)
-20
-15
-10
-5
0
5 0 20 40 60 80 100
Diff
eren
tial P
ress
ure
[Hou
se -
Out
door
] (P
a)
Temperature (deg F)
Baseline Maximum
Weather affects depressurization
Singer & Rapp 38 Feb 26, 2014 Data taken from Koontz et al., 1999; Grimsrud and Hadlich, 1999
![Page 39: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/39.jpg)
-20
-15
-10
-5
0
5 0 20 40 60 80 100
Diff
eren
tial P
ress
ure
[Hou
se -
Out
door
] (P
a)
Temperature (deg F)
Baseline Incremental
Should we subtract “baseline”?
Singer & Rapp 39 Feb 26, 2014 Data taken from Koontz et al., 1999; Grimsrud and Hadlich, 1999
![Page 40: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/40.jpg)
Are the thresholds saving lives or only limiting tightness?
Singer & Rapp 40 Feb 26, 2014
![Page 41: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/41.jpg)
What is the risk of depressurization induced spillage?
Singer & Rapp 41 Feb 26, 2014
P1 = probability that conditions exist to cause backdrafting and spillage if the appliance operates
P2 = probability that the appliance will operate during the time
that the conditions of P1 persist P3 = probability that the appliance emits pollutants at a
sufficient rate to cause an IAQ problem if P1 and P2 occur
Risk = P1 x P2 x P3
![Page 42: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/42.jpg)
Data and calculations are needed…
Singer & Rapp 42 Feb 26, 2014
The probability that conditions exist to cause backdrafting and spillage if the appliance operates depend on: Weather conditions throughout the year Existing fans and usage patterns Appliance location
Risk = P1 x P2 x P3
![Page 43: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/43.jpg)
Data can provide probability an appliance will be operating
Singer & Rapp 43 Feb 26, 2014
Risk = P1 x P2 x P3
143 California homes showed a maximum continuous on-time of 139 minutes in 8 hours for water heaters
Wall furnace could operate continuously
Data for central furnaces & boilers?
![Page 44: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/44.jpg)
Data can provide probability of appliance pollutant emission rates
Singer & Rapp 44 Feb 26, 2014
0%
2%
4%
6%
8%
25!50 50!100 100!150 150!250 250!500 >500
Perc
ent o
f App
lianc
es
Carbon Monoxide Test Results (ppm)
Furnaces Water Heaters
Risk = P1 x P2 x P3
Bohac, D., et al., Ventilation and Depressurization Information for Houses Undergoing Remodeling (2002)
1,427 homes in Twin Cities, MN
![Page 45: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/45.jpg)
Data can provide probability of appliance pollutant emission rates
Singer & Rapp 45 Feb 26, 2014
0%
2%
4%
6%
8%
25!50 50!100 100!150 150!250 250!500 >500
Perc
ent o
f App
lianc
es
Carbon Monoxide Test Results (ppm)
Furnaces Water Heaters
Bohac, D., et al., Ventilation and Depressurization Information for Houses Undergoing Remodeling (2002)
1,427 homes in Twin Cities, MN
Standard “clean and tune” resolved many CO problems
![Page 46: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/46.jpg)
Calculating pollutant concentrations and risk
Feb 26, 2014 Singer & Rapp 46
Mass Balance Pollutants removed
Pollutants added
Mass of Pollutants
![Page 47: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/47.jpg)
What are ppm anyway?
Feb 26, 2014 Singer & Rapp 47
100ppm CO =100 parts CO
1,000,000 parts Air
10ppm CO =10 parts CO
1,000,000 parts Air
![Page 48: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/48.jpg)
How do we get to danger?
Feb 26, 2014 Singer & Rapp 48
Given: 40,000 btuh water heater -> 40 ft3 fuel / h Need roughly 10 ft3 air per ft3 fuel
-> 400 ft3 exhaust per hour Assume:
1000 ppm CO in exhaust 10,000 ft3 home (1250 sf x 8 ft ceiling) 1 h of spillage with no ventilation
1000ppm CO! 400 ft3
10, 000 ft3= 40ppm CO
This is a health hazard but not a life-safety hazard
![Page 49: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/49.jpg)
But we can’t assume no ventilation… That’s how we get depressurization!
Singer & Rapp 49 Feb 26, 2014
![Page 50: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/50.jpg)
40,000 btuh appliance spilling for five minutes of every hour
Singer & Rapp 50 Feb 26, 2014
0 2 4 6 8 10 12 14 16 18 20 22 240
5
10
15
Indo
or C
O C
once
ntra
tion
(ppm
v)
Time (hr)
Flue AF-CO=200ppmFlue AF-CO=1200ppm
2400 sqft house 4 ACH50 -2 Pa depressurization
![Page 51: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/51.jpg)
For a house half the size, pollutant levels would be twice as high
Singer & Rapp 51 Feb 26, 2014
0 2 4 6 8 10 12 14 16 18 20 22 240
5
10
15
Indo
or C
O C
once
ntra
tion
(ppm
v)
Time (hr)
Flue AF-CO=200ppmFlue AF-CO=1200ppm
1200 sqft house 4 ACH50 -2 Pa depressurization
![Page 52: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/52.jpg)
What do simulations and data tell us?
Greatest hazard is when flow just reverses (lowest dilution)
Increasing depressurization increases exhaust airflow, which dilutes any emitted CO
Halving the house size, ACH50, or doubling the appliance size, doubles ambient CO
BPI and RESNET CO and depressurizations limits are overly conservative
Recommend use of range hood when cooking
Advise against unvented heaters and fireplaces
Feb 26, 2014 Singer & Rapp 52
![Page 53: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/53.jpg)
Unvented combustion appliances pose the highest health risk
Appliance Pollutant Exposure Risk
Induced Draft Very Low: Unlikely to backdraft and spill
Water heater Low: non-continuous operation; vented
Vented furnace Medium-Low: Possible long-term operation; vented; wall furnaces can have lower draft
Range & Ovens Medium-high: 100% spillage in living space; some venting through range hood, higher CO
Unvented heater High: 100% spillage in living space; possible long-term operation; higher CO and NO2
Feb 26, 2014 Singer & Rapp 53
![Page 54: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/54.jpg)
Recommendations: Combustion Safety Diagnostics Focus first on basic safety - Proactively check for unvented heating. Primary appliance has to work. Ask
about other heaters including oven
- Inspect for gas leaks; check appliance burner, flue, combustion air to CAZ
- Check vent sizing and horizontal runs
Focus on finding appliances that could backdraft often - Depressurization draft test with exhaust fans that can run for extended
periods (dryer, bathroom; no range hood on high).
Add safety by checking CO during induced downdraft Confirm range hood is venting & advise it be used
Feb 26, 2014 Singer & Rapp 54
![Page 55: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/55.jpg)
Other Random Thoughts
At <2 ACH50, most likely need sealed combustion
At >5 ACH50, required exhaust flows high enough to protect
We should not try to use WCD diagnostics to find the one in a million hazard scenario
May be able to develop rule of thumb by comparing sum of exhaust fans to cfm50
Combustion safety best ensured with direct-vent combustion
Feb 26, 2014 Singer & Rapp 55
![Page 56: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/56.jpg)
Challenges
Are there CAZ configurations that can become dangerous under rare conditions?
Example: backdraft in poorly ventilated space depletes oxygen, creates combustion problem.
Is this a real problem or too rare to be a concern?
How do we diagnose this potential hazard?
Effective kitchen exhaust combined with a dryer produces substantial depressurization in a tight house
Feb 26, 2014 Singer & Rapp 56
![Page 57: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/57.jpg)
Take Home Points
Life-safety hazards almost always result from broken appliances and venting
Depressurization-induced spillage is a problem when it happens frequently
High flows to cause depressurization are safety feature
Unvented combustion appliances require particular attention as they are effectively “spilling” 100% of the time
Feb 26, 2014 Singer & Rapp 57
![Page 58: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/58.jpg)
If time permits…
Singer & Rapp 58 Feb. 26, 2014
(It didn’t. Reader is cautioned to not refer to information in these extra slides without contacting presenter to confirm accurate understanding.)
![Page 59: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/59.jpg)
Furnaces
Feb 26, 2014 Singer & Rapp 59
![Page 60: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/60.jpg)
Continuous spillage for 8-hours reaches a steady-state concentration
0 2 4 6 80
10
20
30
40
50
60
Indo
or C
O C
once
ntra
tion
(ppm
v)
Time (hr)
Flue AF-CO=200ppmFlue AF-CO=1200ppm
- 1200 sqft home; ACH50=4; 20 kBTU/hr appliance - 8-hours of spillage; -5 Pa depressurization
Feb 26, 2014 Singer & Rapp 60
CO Poisoning (2-3 h) 100 ppm: headache 400 ppm: life threatening
![Page 61: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/61.jpg)
What about a larger furnace? Doubling size doubles indoor CO concentrations
0 2 4 6 80
10
20
30
40
50
60
Indo
or C
O C
once
ntra
tion
(ppm
v)
Time (hr)
Flue AF-CO=200ppmFlue AF-CO=1200ppm
- 1200 sqft home; ACH50=4; 40 kBTU/hr appliance - 8-hours of spillage; -5 Pa depressurization
Feb 26, 2014 Singer & Rapp 61
CO Poisoning (2-3 h) 100 ppm: headache 400 ppm: life threatening
![Page 62: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/62.jpg)
Larger depressurization reduces ambient CO concentrations
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
20
40
60
80
100
Stea
dy-S
tate
Indo
or C
O C
once
ntra
tion
(ppm
)
Depressurization (-Pa)
Flue AF-CO=200ppmFlue AF-CO=1200ppm
- 1200 sqft home; ACH50=4; 40 kBTU/hr appliance - Continuous Spillage (Steady-state concentrations)
Feb 26, 2014 Singer & Rapp 62
CO Poisoning (2-3 h) 100 ppm: headache 400 ppm: life threatening
![Page 63: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/63.jpg)
A wall furnace has less effect on ambient CO in larger homes than smaller homes - ACH50=4; 20 kBTU/hr wall furnace - Spilling continuously (Steady-state concentrations)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
25
50
75
100
Ambi
ent C
O C
once
ntra
tion
(ppm
)
Depressurization (-Pa)
Appliance flue CO-AF= 200 ppmAppliance flue CO-AF= 400 ppmAppliance flue CO-AF= 800 ppm
500 sq. ft.
Feb 26, 2014 Singer & Rapp 63
CO Poisoning (2-3 h) 100 ppm: headache 400 ppm: life threatening
![Page 64: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/64.jpg)
A wall furnace has less effect on ambient CO in larger homes than smaller homes - ACH50=4; 20 kBTU/hr wall furnace - Spilling continuously (Steady-state concentrations)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
25
50
75
100
Ambi
ent C
O C
once
ntra
tion
(ppm
)
Depressurization (-Pa)
Appliance flue CO-AF= 200 ppmAppliance flue CO-AF= 400 ppmAppliance flue CO-AF= 800 ppm
500 sq. ft.
Feb 26, 2014 Singer & Rapp 64
1000 sq. ft. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
25
50
75
100
Ambi
ent C
O C
once
ntra
tion
(ppm
)
Depressurization (-Pa)
Appliance flue CO-AF= 200 ppmAppliance flue CO-AF= 400 ppmAppliance flue CO-AF= 800 ppm
CO Poisoning (2-3 h) 100 ppm: headache 400 ppm: life threatening
![Page 65: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/65.jpg)
Simulations can be used as a screening tool to identify problematic conditions Appliance flue air-free CO in 40 kBTU/hr appliance spilling continuously to maintain specified concentrations (steady-state) 1200 sq. ft., 4 AHC50
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
500
1000
1500
2000
2500
3000
3500
4000
4500
Appl
ianc
e flu
e-ga
s ai
r-fre
e CO
con
cent
ratio
n (p
pm)
Depressurization (-Pa)
Indoor CO-SS = 9ppmIndoor CO-SS = 25ppmIndoor CO-SS = 100ppm
Feb 26, 2014 Singer & Rapp 65
![Page 66: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/66.jpg)
Simulations can be used as a screening tool to identify problematic conditions Appliance flue air-free NO2 in 40 kBTU/hr appliance spilling continuously to maintain specified concentrations (steady-state) 1200 sq. ft., 4 AHC50
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
2
4
6
8
10
12
Appl
ianc
e flu
e-ga
s ai
r-fre
e NO
2 con
cent
ratio
n (p
pm)
Depressurization (-Pa)
Indoor NO2-SS = 0.1ppmIndoor NO2-SS = 0.18ppm
Feb 26, 2014 Singer & Rapp 66
![Page 67: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/67.jpg)
Simulations can be used as a screening tool to identify problematic conditions
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
1000
2000
3000
4000
5000
6000
7000
8000
Critic
al C
O-A
F in
App
lianc
e Fl
ue (p
pm)
Depressurization (-Pa)
Ambient CO-SS = 35ppmAmbient CO-SS = 50ppmAmbient CO-SS = 70ppm
- 500 sq. ft., ACH50=4 - Possible risk at low
depressurization spillage
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150
1000
2000
3000
4000
5000
6000
7000
8000
Critic
al C
O-A
F in
App
lianc
e Fl
ue (p
pm)
Depressurization (-Pa)
Ambient CO-SS = 35ppmAmbient CO-SS = 50ppmAmbient CO-SS = 70ppm
- 1500 sq. ft., ACH50=4 - Minimal risk
Feb 26, 2014 Singer & Rapp 67
Appliance flue air-free CO in 20 kBTU/hr wall furnace spilling continuously to maintain specified concentrations (steady-state)
![Page 68: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/68.jpg)
Water Heaters
Feb 26, 2014 Singer & Rapp 68
![Page 69: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/69.jpg)
Water heaters sometimes operate continuously over 1h
Water heater operation in 143 California homes
- 95th percentile: 59 min
- 75th percentile: 50 min
- Mean: 40 min
Feb 26, 2014 Singer & Rapp 69
![Page 70: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/70.jpg)
Simulation shows 1h of WH backdraft-induced spillage is not a life-safety issue
0 10 20 30 40 50 600
10
20
30
40
50
Indo
or C
O C
once
ntra
tion
(ppm
v)
Time (min)
Flue AF-CO=200ppmFlue AF-CO=1200ppm
Max 1 hr avg = 21 ppm
- 1200 sqft home; ACH50=4; 40 kBTU/hr appliance; - 59 minutes of spillage; -2 Pa depuressurization
CO Poisoning (2-3 hrs) 100 ppm: headache 400 ppm: life threatening
Feb 26, 2014 Singer & Rapp 70
Max 1 hr avg = 3 ppm
![Page 71: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/71.jpg)
Water heaters don’t operate continuously over longer periods: data over 4h period
Water heater operation in 143 California homes
- 95th percentile: 105 min
- 75th percentile: 76 min
- Mean: 63 min
Feb 26, 2014 Singer & Rapp 71
![Page 72: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/72.jpg)
Water heaters don’t operate continuously over longer periods: data over 8h period
Water heater operation in 143 California homes
- 95th:139 min
- 75th percentile: 96 min
- Mean: 76 min
Feb 26, 2014 Singer & Rapp 72
![Page 73: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/73.jpg)
0 2 4 6 8 10 12 14 16 18 20 22 240
5
10
15
20
Indo
or C
O C
once
ntra
tion
(ppm
)
Time (hr)
Steady-State, Flue AF-CO=200ppmCycling, Flue AF-CO=200ppm
- 1000 sqft home; ACH50=4; 40 kBTU/hr appliance, 400 ppm CO-AF - 139 minutes of spillage, -2 Pa depressurization
Feb 26, 2014 Singer & Rapp 73
CO Poisoning (2-3 h) 100 ppm: headache 400 ppm: life threatening
Simulation shows 8h of WH backdraft-induced spillage is not a life-safety issue
![Page 74: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/74.jpg)
Cooking
Feb 26, 2014 Singer & Rapp 74
![Page 75: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/75.jpg)
Estimated exposures to pollutants from natural gas cooking burners in SoCal
75
iiiiioutiii LRaVCVCkCaVPE
dtCV −−−+=∂
,
a
iEik
ioutC ,
Physics-based simulation of each home
Apply to large sample of homes that cook with gas
Data from RASS: - Data on age, size - Demographics - Cooking frequency
NHAPS occupancy patterns Emissions measured from used stoves. Cooking times from surveys
Using LBNL’s Population Impact Assessment Model
Feb 26, 2014 Singer & Rapp
![Page 76: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/76.jpg)
Simulations show many homes exceeding air quality standards when no range hood is used
Singer & Rapp 76 Feb 26, 2014
500
400
300
200
100
030
30
25
20
15
10
5
0
200
150
100
50
0
NO2 (ppb)
CO (ppm)
HCHO (ppb)
No kitchen exhaust
55% eff. range hood
No kitchen exhaust
55% eff. range hood
No kitchen exhaust
55% eff. range hood
Use of 55% efficient range hood reduces exceedances
Highest 1h concentrations during typical week in winter
![Page 77: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/77.jpg)
Measurements show that cooktops are most common problem in California
Singer & Rapp 77
Hig
hest
1h
CO
(ppm
) In
door
-em
itted
NO
2 (pp
b)
Results from 5-6 day monitoring in ~350 California homes
Feb 26, 2014
![Page 78: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/78.jpg)
Unvented Heaters and Fireplaces
Feb 26, 2014 Singer & Rapp 78
![Page 79: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/79.jpg)
Room concentrations follow CO concentrations from unvented fireplaces (also see notes for % failures)
Francisco, D., et al., Measured concentrations of combustion gases from the use of unvented gas fireplaces (2010)
Feb 26, 2014 Singer & Rapp 79
Kitchen event
05
1015
20
Car
bon
mon
oxid
e co
ncen
trat
ion,
ppm
02feb2006 03feb2006 04feb2006 05feb2006 06feb2006
Time
Mantel Distant bedroom
![Page 80: Backdrafting Overblown! - RESNET · Percent of Appliances Carbon Monoxide Test Results (ppm) Furnaces Water Heaters Risk = P 1 x P 2 x P 3 Bohac, D., et al., Ventilation and Depressurization](https://reader034.vdocuments.site/reader034/viewer/2022051914/6005711377be240ab1054189/html5/thumbnails/80.jpg)
Prevent use of unvented heaters and fireplaces Located in the living space and continuously spill
combustion gases
Increase risk CO, NO2, and moisture problems
Produce 1qt/hr of water vapor
Canada and many U.S. states ban the use of unvented heaters
http://ventyes.org/
Feb 26, 2014 Singer & Rapp 80