axial mixed flow fan mxa series · mxa 630/18m/7-7 1450rpm - performance certified is for...

20
AXIAL MIXED FLOW FAN MXA Series

Upload: others

Post on 18-Mar-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

AXIAL MIXED FLOW FAN

MXA Series

Page 2: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

The MXA Series has the size advantage over comparable tube-axial, vane–axial, tubular–centrifugal, and centrifugal type fans for the same duty, making the MXA Series the ideal choice for energy-conscious commercial and industrial applications requiring high airflow volume, moderate pressure capacity, high efficiency, low noise, and compactness where installation space is a limiting criterion.

Finish:

Painted or galvanised for steel parts finish. Operation Temperature:

• General ventilation: -20 to +55°C. • Smoke exhaust system: 250°C/300°C/400°C* -

1~2 hour. (TÜV SÜD certified) *( For high temperature (250~400°C) application please

contact Kruger ) Motor:

• General ventilation: Total Enclosed Fan Cooled (TEFC), Class “F”.

• Smoke exhaust system: Totally enclosed High Temperature Rated (250°C/300°C/400°C

TÜV SÜD certified). IP54 protection. Standard motors up to 2.2kW are supplied with DOL starting. Motors 3.0kW and above are with star/delta starting. Motors of other specification are available upon request. Air flow direction:

Air flow from impeller to motor. Accessories:

Mounting feet, hanger and other accessories can be supplied upon request.

Application:

General ventilation and smoke extraction in various commercial and industrial applications, where moderate pressure, high efficiency, and high airflow volume with quiet operation are required. Typical applications include commercial buildings, hospitals & museums, schools & libraries, theatres & auditoriums, factories & processes, public transit stations (MRTs) etc. Range:

Size: 450-1400 Volume Range: 4000 -90,000 CMH Pressure Capacity: 200 - 2000 Pa Construction:

• Cast aluminium blade impeller, statically and dynamically balanced to ISO 1940 and AMCA 204-05-G2.5 standard.

• All fans after assembly are trim-balanced to ISO 1940 and AMCA 204-G2.5 standard.

• Double flanged casing and rigid motor support are made of heavy gauge steel.

• Tube casing with built-in outlet guide vane.

Kruger Ventilation Industries Pte Ltdcertifies that the MXA series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

Axial Mixed flow Tubular Centrifugal

The MXA Series features characteristic advantages of both the axial and the centrifugal type fan. These unique mixed flow fans, with aerodynamically designed impeller and vane system, lead air through the impeller in both the axial and the radial directions, developing the desired pressure characteristics similar to centrifugal fans but with an axial air path suitable for straight –through installation .

Features

Axial Mixed Flow Fan (Direct Driven) MXA Series

Page 3: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

*Weight without motor. **Please consult Kruger for special request.

Model Size A B C D N Φ Weight(kg) 450 450 490 530 470 12 10 33

500 500 540 580 480 12 10 40

560 560 605 660 540 12 10 50 630 630 675 730 580 12 10 72 710 710 755 810 630 18 12 96 800 800 845 900 750 18 12 128 900 900 945 1000 850 18 12 160 1000 1000 1050 1100 900 24 12 225 1120 1120 1185 1250 1050 24 12 295 1250 1250 1315 1380 1200 24 12 416 1400 1400 1465 1530 1250 32 14 580

Dimension

MODEL: MXA 1120 / 25M / 9-9 / 25˚ - /

Blade angle 15˚, 20˚, 25˚, 30˚, 35˚ Motor power kW Motor no. of pole – 2, 4, 6 or 8

Blade model Blade number

Nomenclature

Axial Mixed Flow Fan (Direct Driven) MXA Series

Page 4: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 450/12M/7-71450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

60

120

180

240

300

3600.0 0.5 1.0 1.5 2.0 2.5 3.0

Tota

l Pre

ssur

e (P

a)

0.0

0.2

0.4

0.6

0.8

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 0.5 1.0 1.5 2.0 2.5 3.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°

30° 35°

20°25°

0 3 6 9 12 15 18

25°

35°

20°

γ=1.2kg/m3

Page 5: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 500/12M/8-81450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

60

120

180

240

300

360

420

4800.0 0.8 1.6 2.4 3.2 4.0

Tota

l Pre

ssur

e (P

a)

0.0

0.4

0.8

1.2

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°30° 35°

20° 25°

0 4 8 12 16 20

25°

35°

20°

γ=1.2kg/m3

Page 6: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 560/12M/9-91450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

500

6000.0 1.0 2.0 3.0 4.0 5.0 6.0

Tota

l Pre

ssur

e (P

a)

0.0

0.4

0.8

1.2

1.6

2.0

2.4

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 1.0 2.0 3.0 4.0 5.0 6.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°

30° 35°

20° 25°

0 4 8 12 16 20 24

25°

35°

20°

γ=1.2kg/m3

Page 7: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 630/18M/7-71450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

500

600

7000.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0

Tota

l Pre

ssur

e (P

a)

0.0

1.0

2.0

3.0

4.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°

30° 35°

20°25°

0 5 10 15 20 25

25°

35°

20°

γ=1.2kg/m3

Page 8: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 710/18M/8-8950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

4000.0 2.0 4.0 6.0 8.0

Tota

l Pre

ssur

e (P

a)

0.0

0.5

1.0

1.5

2.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 2.0 4.0 6.0 8.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25° 20°

15°

15°30° 35°

20°25°

0 5 10 15 20

25°

35°

20°

γ=1.2kg/m3

Page 9: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 710/18M/8-81450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

500

600

700

800

9000.0 2.0 4.0 6.0 8.0 10.0 12.0

Tota

l Pre

ssur

e (P

a)

0.0

2.0

4.0

6.0

8.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 2.0 4.0 6.0 8.0 10.0 12.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°25°

20°

15°

15°30° 35°

20° 25°

0 5 10 15 20 25 30

25°

35°

20°

γ=1.2kg/m3

Page 10: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 800/18M/9-9950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

5000.0 3.0 6.0 9.0 12.0

Tota

l Pre

ssur

e (P

a)

0.0

1.0

2.0

3.0

4.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 3.0 6.0 9.0 12.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25° 20°

15°

15°

30° 35°

20° 25°

0 5 10 15 20

25°

35°

20°

γ=1.2kg/m3

Page 11: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 800/18M/9-91450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

200

400

600

800

1000

12000.0 3.0 6.0 9.0 12.0 15.0 18.0

Tota

l Pre

ssur

e (P

a)

0.0

4.0

8.0

12.0

16.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 3.0 6.0 9.0 12.0 15.0 18.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°

30° 35°

20° 25°

0 5 10 15 20 25 30 35

25°

35°

20°

γ=1.2kg/m3

Page 12: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 900/25M/7-7950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

500

6000.0 3.0 6.0 9.0 12.0 15.0

Tota

l Pre

ssur

e (P

a)

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 3.0 6.0 9.0 12.0 15.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30° 25°

20° 15°

15°

30° 35° 20° 25°

0 5 10 15 20

25°

35°

20°

γ=1.2kg/m3

Page 13: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 900/25M/7-71450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

200

400

600

800

1000

1200

1400

16000.0 4.0 8.0 12.0 16.0 20.0 24.0

Tota

l Pre

ssur

e (P

a)

0.0

4.0

8.0

12.0

16.0

20.0

24.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 4.0 8.0 12.0 16.0 20.0 24.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°

20°15°

15°

30° 35°20° 25°

0 6 12 18 24 30 36

25°

35°

20°

γ=1.2kg/m3

Page 14: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 1000/25M/8-8950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

500

600

700

8000.0 5.0 10.0 15.0 20.0

Tota

l Pre

ssur

e (P

a)

0.0

3.0

6.0

9.0

12.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 5.0 10.0 15.0 20.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

15°

30° 35°20°

25°

30°

15°

35°

30°

25°20°

15°

0 6 12 18 24

25°

35°

20°

γ=1.2kg/m3

Page 15: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 1000/25M/8-81450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

200

400

600

800

1000

1200

1400

1600

18000.0 6.0 12.0 18.0 24.0 30.0 36.0

Tota

l Pre

ssur

e (P

a)

0.0

12.0

24.0

36.0

48.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 6.0 12.0 18.0 24.0 30.0 36.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°30° 35°

20°25°

0 6 12 18 24 30 36 42

25°

35°

20°

γ=1.2kg/m3

Page 16: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 1120/25M/9-9950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

100

200

300

400

500

600

700

800

9000.0 5.0 10.0 15.0 20.0 25.0 30.0

Tota

l Pre

ssur

e (P

a)

0.0

5.0

10.0

15.0

20.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 5.0 10.0 15.0 20.0 25.0 30.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

15°

30° 35°

20° 25°

30°

15°

35°

30°

25°

20°15°

0 10 20 30

25°

35°

20°

γ=1.2kg/m3

Page 17: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 1120/25M/9-91450rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

400

800

1200

1600

2000

24000.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0 48.0

Tota

l Pre

ssur

e (P

a)

0.0

20.0

40.0

60.0

80.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0 48.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°20°

15°

15°

30° 35°

20° 25°

0 10 20 30 40

25°

35°

20°

γ=1.2kg/m3

Page 18: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 1250/25M/9-9950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

200

400

600

800

1000

1200

1400

16000.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0

Tota

l Pre

ssur

e (P

a)

0.0

10.0

20.0

30.0

40.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 6.0 12.0 18.0 24.0 30.0 36.0 42.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°

20°15°

15°30° 35°

20°25°

0 6 12 18 24 30

25°

35°

20°

γ=1.2kg/m3

Page 19: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

MXA 1400/25M/10-10950rpm

- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - The AMCA Certified Ratings Seal applies to air performance ratings only.

0

200

400

600

800

1000

1200

1400

1600

18000.0 10.0 20.0 30.0 40.0 50.0 60.0

Tota

l Pre

ssur

e (P

a)

0.0

12.0

24.0

36.0

48.0

60.0

Abs

orbe

d Po

wer

(kW

)

0

20

40

60

80

100

0.0 10.0 20.0 30.0 40.0 50.0 60.0

Tota

l Effi

cien

cy (%

)

Q [m3/s]

Q [m3/s]

V [m/s]

30°

15°

35°

30°

25°

20°15°

15°30° 35°

20° 25°

0 6 12 18 24 30 36

25°

35°

20°

γ=1.2kg/m3

Page 20: AXIAL MIXED FLOW FAN MXA Series · MXA 630/18M/7-7 1450rpm - Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the

• SINGAPORE • SINGAPOREKRUGER VENTILATION INDUSTRIES PTE LTD KRUGER ENGINEERING PTE LTDNo. 17, Tuas Avenue 10 No. 17, Tuas Avenue 10Singapore 639141 Singapore 639141Tel. +65 68611577 - Fax +65 68613577 Tel. +65 68631191 - Fax +65 68631151Email: [email protected] Email: [email protected]

• MALAYSIA • THAILANDKRUVENT INDUSTRIES (M) SDN BHD KRUGER VENTILATION IND. (THAILAND) CO. LTDLot 8, Jalan Perusahaan 2 Batu Caves 30/105 Moo 1 Sinsakorn Industrial EstateIndustrial Area, 68100 Batu Caves Selangor Chetsadawithi Road, Khok Kham Mueng, Sakuthsakorn 74000, THAILANDTel. +603 61888293 - Fax +603 61898843 Tel. +662 1050399 - Fax + 662 1050370-2Email: [email protected] Email: [email protected]

• BEIJING • GUANGZHOUBEIJING KRUGER VENTILATION CO. LTD GUANGZHOU KRUGER M&E INDUSTRIES CO. LTDNo. 1A South Industry Area No. 1270 Maogang Road, HuangpuBeijing Economical And Technological Guangzhou, P.R. China 510700Development Area, Beijing China 100176 Tel. +86 20-32387634 Fax +86 20-32387624Tel. +86 10-67881366 - Fax +86 10-67880566 Email: [email protected]: [email protected]

• HONG KONG • SHANGHAIKRUGER VENTILATION (HONG KONG) LIMITED SHANGHAI KRUGER VENTILATION CO. LTDFlat C, 9/F, Yeung Yiu Chung (No.8) Industrial Building, No. 500 Yuanguo Road, Anting, Jiading,20 Wang Hoi Road, Kowloon Bay, Kowloon, Hong Kong Shanghai 201814 P.R. ChinaTel. +852 22469182 – Fax +852 22469187 Tel. +86 21-69573266 - Fax +86 21-69573296Email: [email protected] Email: [email protected]

• WUHAN • TAIPEIWUHAN KRUGER VENTILATION CO. LTD KRUGER VENTILATION (TAIWAN) CO. LTDXincheng Road 10 , South Dongwu Ave , Dongxihu District, No. 157, Ping-an Rd, Hengfeng Village,Wuhan ,Hubei, P.R.China 430040 Dayuan Shiang Taoyuan County 337, Taiwan(ROC)Tel. +86 27- 83248840 - Fax +86 27- 83261886 Tel. +886 3-3859119 - Fax +886 3-3859118Email: [email protected] Email: [email protected]

• PHILIPPINES • AUSTRALIAKRUGER M&E INDUSTRIES CORPORATION KRUGER VENTILATION (AUSTRALIA) PTY LTDFAPI Compound, E. Rodriguez Ave. 4 Blackfriar Place, Wetherill ParkTunasan, Muntinlupa City, Philippines 1773 NSW 2164, AustraliaTel. +63 2-8622891-97 - Fax +63 2-8621287 Tel. +61 2-97562008 - Fax +61 2-97560808Email: [email protected] Email: [email protected]

• INDONESIA • INDIAP.T. KRUGER VENTILATION INDONESIA KRUGER VENTILATION INDUSTRIES (INDIA) PVT LTDJL. Teuku Umar No.20, Kruger Centre, Mumbai-Nasik Highway,Karawaci - Tangerang 15115, Indonesia Atgaon, Shahapur, Thane 421304, Maharashtra, IndiaTel. +62 21-551288/5513557 - Fax +62 21-5513502 Tel. +91 98607 30999 - Fax +91 2527 240075Email: [email protected] Email: [email protected]

• KOREA • VIETNAMNEOMATE TECHNOLOGY & CONSULTING CO. LTD KRUGER VENTILATION INDUSTRIES PTE LTD2-1010, Ace High Tech City B/D, Mullae-dong 3-ga (Vietnam Representative Office)Yeongdeungpo-gu, Seoul, Korea, 150-972 4th floor, HHM Office Building, 157-159 Xuan Hong St,Tel.+82-2-2679-2052 - Fax. +82-2-2679-2174 Tan Binh Dist, Hochiminh City, VietnamEmail: [email protected] Tel. +84-8-6 2968123 - Fax +84-8-6 2968124

Email: [email protected]

• DUBAIKruger Ventilation Industries, Gulf BranchJebel Ali Free Zone Area (JAFZA)near Roundabout 8, Warehouse no. RA08FC05P.O. Box no. 262949Tel. +971 4 8832017 - Fax. +971 4 8832018Email: [email protected]

T H E K R U G E R G R O U P

KRUGER VENTILATION INDUSTRIES PTE LTD – No. 17 Tuas Avenue 10 – Singapore 639141 – Tel +65 68611577 – Fax +65 68613577The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products. Certified dimension can be provided upon request.

LEA044.E3 December 2010Edition 4Printed on December 2010