AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
Range of adjustable pitch aerofoil blade, axial flow cabinet fans designed for smoke extraction in fire conditions and certified F400-120 and F300-120 (CE marked).Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25mm thickness fireproof fibreglass acoustic insulation (M0).All models incorporate separate high grade diecast aluminium blades locked within a pressed sheet steel hub.
MotorsAvailable, depending upon the model:- with three phase motors in 4 or 6 poles.- with three phase two speed motors 4/8 or 6/12 poles.F400-120 and F300-120 motors are IP55 class H insulation.Electrical supplies:
Three phase 230/400V-50Hz up to 3 kW.Three phase 400V-50Hz, for higher power motors and two speed motors.(See characteristics chart).
Additional informationStandard air direction: form (A) configuration (motor over impeller).
On requestAir direction: form (B) configuration (impeller over motor).
Constructive configurationmodels from 400 to 800
Constructive configuration models from 900 to 1250
F400-120
F300-120
Specific applications
F300-120Car Parks Industrial
kitchensOfficiallyapproved toEN12101-3standard (certificatenumber0370-CPD-0420)
Officiallyapproved toEN12101-3standard (certificatenumber0370-CPD-0955)
Highly versatile range due to different number of available blades and adjustable pitch angles
Impellers with 3, 5, 6, 7 or 9 blades with adjustable pitch angles, allowing the most optimum selection to achieve with everykind of installation requirements.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
Motor approved S1 and S2F400-120 or F300-120certified motors approved forrunning continuously (S1) or for emergency operation (S2).
Corrosion resistanceCasings manufactured fromgalvanised sheet steel. Design enables the casing side panels to be removed and the motorimpeller assembly accessed.
Easy to installRobust base supports facilitate the installation.(Models from 900 to 1250)
Impeller dynamicallybalancedImpeller dynamicallybalanced, according to ISO1940 standard, providingvibration free operation.
Wide blade design: higher pressureWide blade design to ensure the highest efficient airflowperformances.Configuration 1: models from 400 to 630.Configuration 2: models from 710 to 1250.
1 2
REfERENCE
MOTORSf300-120
1 SPEED4 POLES 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 30 37 45
6 POLES 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22
2 SPEED4/8 POLES 0,55/0,09 0,75/0,12 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 4/0,75 5,5/1 7,5/1,5 11/3 14/3,5 17/4,3 20/5 28/6,5 37/9,2 44/11
6/12 POLES 0,55/0,09 0,75/0,12 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 4/0,65 6/1,2 7,5/1,5 9/1,8 12/2,4 17,5/3,5 20/5
MOTORSf400-120
1 SPEED4 POLES 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22 30 37 45
6 POLES 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 11 15 18,5 22
2 SPEED4/8 POLES 0,55/0,09 0,75/0,12 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 4/0,75 5,5/1 7,5/1,5 11/3 14/3,5 17/4,3 20/5 28/6,5 37/9,2 44/11
6/12 POLES 0,55/0,09 0,75/0,12 1,1/0,18 1,5/0,25 2,2/0,37 3/0,55 4/0,65 6/1,2 7,5/1,5 9/1,8 12/2,4 17,5/3,5 20/5
* Note: For 2 speed motors, the powers may have small variations depending on the motor manufacturer.
1 - : Product range2 - : Number of poles3 - : Diameters4 - : Number of blades5 - : Blade pitch angle6 - : Airflow direction7 - : Motor power
C H G T / 6 - 1 0 0 0 - 6 / 8 / A - 1,5 KW
1 2 3 4 5 6 7
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
TECHNICAl CHARACTERISTICS - MOTORS f300-120
CHGT 1 SPEED MODElSTECHNICAl CHARACTERISTICS - 4 POlES - 1450 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
Model Motor power(kW)
full load current(A)
Weight(Kg)
230 V 400 VCHGT/4-400-6/-0,55 0,55 2,36 1,36 47
CHGT/4-450-6/-0,55 0,55 2,36 1,36 49
CHGT/4-500-6/-0,55 0,55 2,36 1,36 54 CHGT/4-500-6/-0,75 0,75 3,20 1,85 60 CHGT/4-500-6/-1,1 1,1 4,23 2,44 62
CHGT/4-560-6/-0,55 0,55 2,36 1,36 59 CHGT/4-560-6/-0,75 0,75 3,20 1,85 65 CHGT/4-560-6/-1,1 1,1 4,52 2,61 67 CHGT/4-560-6/-1,5 1,5 5,70 3,29 72 CHGT/4-560-6/-2,2 2,2 8,23 4,75 78
CHGT/4-630-6/-0,75 0,75 3,20 1,85 69CHGT/4-630-6/-1,1 1,1 4,52 2,61 75 CHGT/4-630-6/-1,5 1,5 5,70 3,29 80 CHGT/4-630-6/-2,2 2,2 8,23 4,75 86 CHGT/4-630-6/-3 3 11,21 6,47 89
CHGT/4-710-3/-0,75 0,75 3,20 1,85 101CHGT/4-710-3/-1,1 1,1 4,52 2,61 107CHGT/4-710-3/-1,5 1,5 5,70 3,29 112CHGT/4-710-3/-2,2 2,2 8,00 4,61 118CHGT/4-710-3/-3 3 8,23 4,75 121
CHGT/4-710-6/-1,1 1,1 8,30 4,80 110CHGT/4-710-6/-1,5 1,5 5,50 3,20 115CHGT/4-710-6/-2,2 2,2 8,30 4,80 121CHGT/4-710-6/-3 3 11,30 6,50 124CHGT/4-710-6/-4 4 – 8,60 136
CHGT/4-800-3/-1,1 1,1 4,52 2,61 110 CHGT/4-800-3/-1,5 1,5 5,70 3,29 112CHGT/4-800-3/-2,2 2,2 8,23 4,75 118CHGT/4-800-3/-3 3 11,21 6,47 122CHGT/4-800-3/-4 4 – 8,18 134CHGT/4-800-3/-5,5 5,5 – 11,00 147
CHGT/4-800-6/-1,5 1,5 5,70 3,29 115CHGT/4-800-6/-2,2 2,2 8,23 4,75 120CHGT/4-800-6/-3 3 11,21 6,47 123CHGT/4-800-6/-4 4 – 8,18 135CHGT/4-800-6/-5,5 5,5 – 11,00 148CHGT/4-800-6/-7,5 7,5 – 14,20 162
CHGT/4-800-9/-2,2 2,2 8,04 4,64 138CHGT/4-800-9/-3 3 11,21 6,47 141CHGT/4-800-9/-4 4 – 7,62 153CHGT/4-800-9/-5,5 5,5 – 10,60 166CHGT/4-800-9/-7,5 7,5 – 14,20 180CHGT/4-800-9/-11 11 – 22,10 207We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight(Kg)
230 V 400 VCHGT/4-900-6/-3 3 11,21 6,47 180CHGT/4-900-6/-4 4 – 8,18 188CHGT/4-900-6/-5,5 5,5 – 11,00 201CHGT/4-900-6/-7,5 7,5 – 14,20 215CHGT/4-900-6/-11 11 – 22,10 242CHGT/4-900-6/-15 15 – 29,10 270
CHGT/4-900-9/-4 4 – 9,5 181CHGT/4-900-9/-5,5 5,5 – 12,5 194CHGT/4-900-9/-7,5 7,5 – 16 208CHGT/4-900-9/-11 11 – 22,10 235CHGT/4-900-9/-15 15 – 29,10 263CHGT/4-900-9/-18,5 18,5 – 35,10 311
CHGT/4-1000-6/-4 4 – 8,18 175CHGT/4-1000-6/-5,5 5,5 – 11,00 188CHGT/4-1000-6/-7,5 7,5 – 14,20 202CHGT/4-1000-6/-11 11 – 22,10 229CHGT/4-1000-6/-15 15 – 29,10 257CHGT/4-1000-6/-18,5 18,5 – 35,10 305CHGT/4-1000-6/-22 22 – 41,00 306CHGT/4-1000-9/-22 22 – 41,00 311
CHGT/4-1000-9/-5,5 5,5 – 11,00 193CHGT/4-1000-9/-7,5 7,5 – 14,20 207CHGT/4-1000-9/-11 11 – 22,10 208CHGT/4-1000-9/-15 15 – 29,10 262CHGT/4-1000-9/-18,5 18,5 – 35,10 310
CHGT/4-1250-6/-15 15 – 29,10 414CHGT/4-1250-6/-18,5 18,5 – 35,10 462CHGT/4-1250-6/-22 22 – 41,00 463CHGT/4-1250-6/-30 30 – 56,00 523CHGT/4-1250-6/-37 37 – 67,40 624CHGT/4-1250-6/-45 45 – 81,60 670
CHGT/4-1250-9/-15 15 – 29,10 419CHGT/4-1250-9/-18,5 18,5 – 35,10 467CHGT/4-1250-9/-22 22 – 41,00 468CHGT/4-1250-9/-30 30 – 56,00 528CHGT/4-1250-9/-37 37 – 67,40 629CHGT/4-1250-9/-45 45 – 81,60 675CHGT/4-1250-9/-15 15 – 29,10 419CHGT/4-1250-9/-18,5 18,5 – 35,10 467CHGT/4-1250-9/-22 22 – 41,00 468CHGT/4-1250-9/-30 30 – 56,00 528CHGT/4-1250-9/-37 37 – 67,40 629CHGT/4-1250-9/-45 45 – 81,60 675
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
TECHNICAl CHARACTERISTICS - MOTORS f300-120
CHGT 1 SPEED MODElSTECHNICAl CHARACTERISTICS - 6 POlES - 950 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
Model Motor power(kW)
full load current(A)
Weight(Kg)
230 V 400 VCHGT/6-500-6/-0,55 0,55 2,79 1,61 56
CHGT/6-560-6/-0,55 0,55 2,79 1,61 78
CHGT/6-630-6/-0,55 0,55 2,79 1,61 85CHGT/6-630-6/-0,75 0,75 3,27 1,89 89CHGT/6-630-6/-1,1 1,1 5,27 3,04 92
CHGT/6-710-3/-0,55 0,55 2,79 1,61 98CHGT/6-710-3/-0,75 0,75 3,27 1,89 102
CHGT/6-710-6/-0,55 0,55 2,90 1,70 101CHGT/6-710-6/-0,75 0,75 4,20 2,40 105CHGT/6-710-6/-1,1 1,1 4,90 2,82 108
CHGT/6-800-3/-0,55 0,55 2,79 1,61 104CHGT/6-800-3/-0,75 0,75 3,27 1,89 108CHGT/6-800-3/-1,1 1,1 5,27 3,04 111CHGT/6-800-3/-1,5 1,5 6,75 3,90 115
CHGT/6-800-6/-0,55 0,55 2,79 1,61 107CHGT/6-800-6/-0,75 0,75 3,27 1,89 111CHGT/6-800-6/-1,1 1,1 5,27 3,04 114CHGT/6-800-6/-1,5 1,5 6,75 3,90 118CHGT/6-800-6/-2,2 2,2 9,28 5,36 126
CHGT/6-800-9/-0,75 0,75 3,60 2,08 115CHGT/6-800-9/-1,1 1,1 5,07 2,93 118CHGT/6-800-9/-1,5 1,5 6,55 3,78 122CHGT/6-800-9/-2,2 2,2 9,28 5,36 130CHGT/6-800-9/-3 3 11,81 6,82 147
CHGT/6-900-6/-1,5 1,5 6,75 3,90 161CHGT/6-900-6/-2,2 2,2 9,28 5,36 169CHGT/6-900-6/-3 3 11,81 6,82 186CHGT/6-900-6/-4 4 – 9,20 192We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight
(Kg)230 V 400 VCHGT/6-900-9/-1,5 1,5 6,75 3,90 165CHGT/6-900-9/-2,2 2,2 9,28 5,36 173CHGT/6-900-9/-3 3 11,81 6,82 190CHGT/6-900-9/-4 4 – 9,20 196CHGT/6-900-9/-5,5 5,5 – 13,00 206
CHGT/6-1000-6/-1,5 1,5 6,75 3,90 159CHGT/6-1000-6/-2,2 2,2 9,28 5,36 167CHGT/6-1000-6/-3 3 11,81 6,82 184CHGT/6-1000-6/-4 4 – 9,20 190CHGT/6-1000-6/-5,5 5,5 – 13,00 200CHGT/6-1000-6/-7,5 7,5 – 15,00 233
CHGT/6-1000-9/-2,2 2,2 9,28 5,36 172CHGT/6-1000-9/-3 3 11,81 6,82 189CHGT/6-1000-9/-4 4 – 9,20 195CHGT/6-1000-9/-5,5 5,5 – 13,00 205CHGT/6-1000-9/-7,5 7,5 – 15,00 238
CHGT/6-1250-6/-4 4 – 9,20 347CHGT/6-1250-6/-5,5 5,5 – 13,00 357CHGT/6-1250-6/-7,5 7,5 – 15,00 390CHGT/6-1250-6/-11 11 – 21,70 415CHGT/6-1250-6/-15 15 – 27,60 453
CHGT/6-1250-9/-5,5 5,5 – 13,00 362CHGT/6-1250-9/-7,5 7,5 – 15,00 395CHGT/6-1250-9/-11 11 – 21,70 420CHGT/6-1250-9/-15 15 – 27,60 458CHGT/6-1250-9/-18,5 18,5 – 36,10 508CHGT/6-1250-9/-22 22 – 41,40 530
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
TECHNICAl CHARACTERISTICS - MOTORS f300-120
CHGT 2 SPEED MODElSTECHNICAl CHARACTERISTICS - 4/8 POlES - 1450/730 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
Model Motor power(kW)
full load current(A)
Weight(Kg)
V1 V2 V1 V2CHGT/4/8-400-6/-0,55/0,09 0,55 0,09 1,7 0,65 47
CHGT/4/8-450-6/-0,55/0,09 0,55 0,09 1,7 0,65 49
CHGT/4/8-500-6/-0,55/0,09 0,55 0,09 1,7 0,65 54 CHGT/4/8-500-6/-0,75/0,12 0,75 0,12 1,86 0,84 60 CHGT/4/8-500-6/-1,1/0,18 1,1 0,18 2,73 1,21 62
CHGT/4/8-560-6/-0,55/0,09 0,55 0,09 1,7 0,65 59 CHGT/4/8-560-6/-0,75/0,12 0,75 0,12 1,86 0,84 65 CHGT/4/8-560-6/-1,1/0,18 1,1 0,18 2,73 1,21 83CHGT/4/8-560-6/-1,5/0,25 1,5 0,25 3,65 1,6 93CHGT/4/8-560-6/-2,2/0,37 2,2 0,37 4,7 1,66 101
CHGT/4/8-630-6/-0,75/0,12 0,75 0,12 1,86 0,84 72CHGT/4/8-630-6/-1,1/0,18 1,1 0,18 2,73 1,21 90CHGT/4/8-630-6/-1,5/0,25 1,5 0,25 3,65 1,6 100CHGT/4/8-630-6/-2,2/0,37 2,2 0,37 4,7 1,66 108CHGT/4/8-630-6/-3/0,55 3 0,55 6,29 2,35 109
CHGT/4/8-710-3/-0,75/0,12 0,75 0,12 1,86 0,84 101CHGT/4/8-710-3/-1,1/0,18 1,1 0,18 2,73 1,21 103CHGT/4/8-710-3/-1,5/0,25 1,5 0,25 3,65 1,6 113CHGT/4/8-710-3/-2,2/0,37 2,2 0,37 4,7 1,66 120CHGT/4/8-710-3/-3/0,55 3 0,55 6,29 2,35 121
CHGT/4/8-710-6/-1,1/0,18 1,1 0,18 2,73 1,21 106CHGT/4/8-710-6/-1,5/0,25 1,5 0,25 3,65 1,6 116CHGT/4/8-710-6/-2,2/0,37 2,2 0,37 4,7 1,66 123CHGT/4/8-710-6/-3/0,55 3 0,55 6,29 2,35 124CHGT/4/8-710-6/-4/0,75 4 0,75 8,44 2,55 131
CHGT/4/8-800-3/-1,1/0,18 1,1 0,18 2,73 1,21 109CHGT/4/8-800-3/-1,5/0,25 1,5 0,25 3,65 1,6 119CHGT/4/8-800-3/-2,2/0,37 2,2 0,37 4,7 1,66 127CHGT/4/8-800-3/-3/0,55 3 0,55 6,29 2,35 128CHGT/4/8-800-3/-4/0,75 4 0,75 8,44 2,25 135CHGT/4/8-800-3/-5,5/1,1 5,5 1,1 11,7 3,7 157We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight(Kg)
V1 V2 V1 V2CHGT/4/8-800-6/-1,5/0,25 1,5 0,25 3,65 1,6 122CHGT/4/8-800-6/-2,2/0,37 2,2 0,37 4,7 1,66 130CHGT/4/8-800-6/-3/0,55 3 0,55 6,29 2,35 131CHGT/4/8-800-6/-4/0,75 4 0,75 8,44 2,25 138CHGT/4/8-800-6/-5,5/1,1 5,5 1,1 11,7 3,7 160CHGT/4/8-800-6/-7,5/1,5 7,5 1,5 15,9 4,72 173
CHGT/4/8-800-9/-2,2/0,37 2,2 0,37 4,7 1,66 134CHGT/4/8-800-9/-3/0,55 3 0,55 6,29 2,35 135CHGT/4/8-800-9/-4/0,75 4 0,75 8,44 2,25 142CHGT/4/8-800-9/-5,5/1,1 5,5 1,1 11,7 3,7 164CHGT/4/8-800-9/-7,5/1,5 7,5 1,5 15,9 4,72 177
CHGT/4/8-900-6/-3/0,55 3 0,55 6,29 2,35 174CHGT/4/8-900-6/-4/0,75 4 0,75 8,44 2,25 181CHGT/4/8-900-6/-5,5/1,1 5,5 1,1 11,7 3,7 203CHGT/4/8-900-6/-7,5/1,5 7,5 1,5 15,9 4,72 216CHGT/4/8-900-6/-11/3 11 3 21 7 249CHGT/4/8-900-6/-14/3,5 14 3,5 26,5 8,45 269
CHGT/4/8-900-9/-4/0,75 4 0,75 8,44 2,25 185CHGT/4/8-900-9/-5,5/1,1 5,5 1,1 11,7 3,7 207CHGT/4/8-900-9/-7,5/1,5 7,5 1,5 15,9 4,72 220CHGT/4/8-900-9/-11/3 11 3 21 7 253CHGT/4/8-900-9/-14/3,5 14 3,5 26,5 8,45 273CHGT/4/8-900-9/-17/4,3 17 4,3 33,4 12,3 301
CHGT/4/8-1000-6/-4/0,75 4 0,75 8,44 2,25 179
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
TECHNICAl CHARACTERISTICS - MOTORS f300-120
CHGT 2 SPEED MODElSTECHNICAl CHARACTERISTICS - 6/12 POlES - 950/475 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
Model Motor power(kW)
full load current(A)
Weight(Kg)
V1 V2 V1 V2CHGT/6/12-500-6/-0,55/0,09 0,55 0,09 2,07 0,94 62
CHGT/6/12-560-6/-0,55/0,09 0,55 0,09 2,07 0,94 84
CHGT/6/12-630-6/-0,55/0,09 0,55 0,09 2,07 0,94 91CHGT/6/12-630-6/-0,75/0,12 0,75 0,12 2,28 1,02 93CHGT/6/12-630-6/-1,1/0,18 1,1 0,18 4,49 1,67 105
CHGT/6/12-710-3/-0,55/0,09 0,55 0,09 2,07 0,94 104CHGT/6/12-710-3/-0,75/0,12 0,75 0,12 2,28 1,02 106
CHGT/6/12-710-6/-0,55/0,09 0,55 0,09 2,07 0,94 107CHGT/6/12-710-6/-0,75/0,12 0,75 0,12 2,28 1,02 109CHGT/6/12-710-6/-1,1/0,18 1,1 0,18 4,49 1,67 121
CHGT/6/12-800-3/-0,55/0,09 0,55 0,09 2,07 0,94 110CHGT/6/12-800-3/-0,75/0,12 0,75 0,12 2,28 1,02 112CHGT/6/12-800-3/-1,1/0,18 1,1 0,18 4,49 1,67 124CHGT/6/12-800-3/-1,5/0,25 1,5 0,25 4,24 1,67 127
CHGT/6/12-800-6/-0,55/0,09 0,55 0,09 2,07 0,94 107CHGT/6/12-800-6/-0,75/0,12 0,75 0,12 2,28 1,02 115CHGT/6/12-800-6/-1,1/0,18 1,1 0,18 4,49 1,67 127CHGT/6/12-800-6/-1,5/0,25 1,5 0,25 4,24 1,67 130CHGT/6/12-800-6/-2,2/0,37 2,2 0,37 5,9 2,3 131
CHGT/6/12-800-9/-0,75/0,12 0,75 0,12 2,28 1,02 119CHGT/6/12-800-9/-1,1/0,18 1,1 0,18 4,49 1,67 131CHGT/6/12-800-9/-1,5/0,25 1,5 0,25 4,24 1,67 134CHGT/6/12-800-9/-2,2/0,37 2,2 0,37 5,9 2,3 135CHGT/6/12-800-9/-3/0,55 3 0,55 8,87 3,80 147
CHGT/6/12-900-6/-1,1/0,18 1,1 0,18 4,49 1,67 174CHGT/6/12-900-6/-1,5/0,25 1,5 0,25 4,24 1,67 181CHGT/6/12-900-6/-2,2/0,37 2,2 0,37 5,9 2,3 191CHGT/6/12-900-6/-3/0,55 3 0,55 8,87 3,80 216CHGT/6/12-900-6/-4/0,65 4 0,65 10 3,5 210We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight(Kg)
V1 V2 V1 V2CHGT/6/12-900-9/-1,5/0,25 1,5 0,25 4,24 1,67 185CHGT/6/12-900-9/-2,2/0,37 2,2 0,37 5,9 2,3 195CHGT/6/12-900-9/-3/0,55 3 0,55 8,87 3,80 220CHGT/6/12-900-9/-4/0,65 4 0,65 10 3,5 206CHGT/6/12-900-9/-6/1,2 6 1,2 14,4 5,5 262
CHGT/6/12-1000-6/-1,5/0,25 1,5 0,25 4,24 1,67 171CHGT/6/12-1000-6/-2,2/0,37 2,2 0,37 5,9 2,3 172CHGT/6/12-1000-6/-3/0,55 3 0,55 8,87 3,80 209CHGT/6/12-1000-6/-4/0,65 4 0,65 9,31 2,94 209CHGT/6/12-1000-6/-6/1,2 6 1,2 13,40 5,58 256
CHGT/6/12-1000-9/-2,2/0,37 2,2 0,37 5,73 2,18 177CHGT/6/12-1000-9/-3/0,55 3 0,55 8,87 3,80 214CHGT/6/12-1000-9/-4/0,65 4 0,65 9,31 2,94 214CHGT/6/12-1000-9/-6/1,2 6 1,2 13,40 5,58 261CHGT/6/12-1000-9/-7,5/1,5 7,5 1,5 16,40 6,49 268
CHGT/6/12-1250-6/-4/0,65 4 0,65 9,31 2,94 365CHGT/6/12-1250-6/-6/1,2 6 1,2 13,40 5,58 413CHGT/6/12-1250-6/-7,5/1,5 7,5 1,5 16,40 6,49 390CHGT/6/12-1250-6/-9/1,8 9 1,8 18,90 7,08 445CHGT/6/12-1250-6/-12/2,4 12 2,4 23,40 8,07 506CHGT/6/12-1250-6/-17,5/3,5 17,5 3,5 40 14,5 538
CHGT/6/12-1250-9/-6/1,2 6 1,2 13,40 5,58 418CHGT/6/12-1250-9/-7,5/1,5 7,5 1,5 16,40 6,49 450CHGT/6/12-1250-9/-9/1,8 9 1,8 18,90 7,08 458CHGT/6/12-1250-9/-12/2,4 12 2,4 23,40 8,07 511CHGT/6/12-1250-9/-17,5/3,5 17,5 3,5 40 14,5 542CHGT/6/12-1250-9/-20/5 20 5 54,2 23,5 564
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
Model Motor power(kW)
full load current(A)
Weight
(Kg)230 V 400 VCHGT/4-400-6/-0,55 0,55 2,36 1,36 36
CHGT/4-450-6/-0,55 0,55 2,36 1,36 38
CHGT/4-500-6/-0,55 0,55 2,36 1,36 43CHGT/4-500-6/-0,75 0,75 3,20 1,85 49CHGT/4-500-6/-1,1 1,1 4,23 2,44 51
CHGT/4-560-6/-0,55 0,55 2,36 1,36 45CHGT/4-560-6/-0,75 0,75 3,20 1,85 51CHGT/4-560-6/-1,1 1,1 4,52 2,61 53CHGT/4-560-6/-1,5 1,5 5,70 3,29 58CHGT/4-560-6/-2,2 2,2 8,23 4,75 64
CHGT/4-630-6/-0,75 0,75 3,20 1,85 53CHGT/4-630-6/-1,1 1,1 4,52 2,61 59CHGT/4-630-6/-1,5 1,5 5,70 3,29 64CHGT/4-630-6/-2,2 2,2 8,23 4,75 70CHGT/4-630-6/-3 3 11,21 6,47 73
CHGT/4-710-5/-1,1 1,1 4,52 2,61 84CHGT/4-710-5/-1,5 1,5 5,70 3,29 85
CHGT/4-710-7/-2,2 2,2 8,23 4,75 91CHGT/4-710-7/-3 3 11,21 6,47 94CHGT/4-710-7/-4 4 – 8,18 107CHGT/4-710-7/-5,5 5,5 – 11,00 120
CHGT/4-800-3/-1,1 1,1 4,52 2,61 89CHGT/4-800-3/-1,5 1,5 5,70 3,29 91CHGT/4-800-3/-2,2 2,2 8,23 4,75 97CHGT/4-800-3/-3 3 11,21 6,47 101CHGT/4-800-3/-4 4 – 8,18 113CHGT/4-800-3/-5,5 5,5 – 11,00 126
CHGT/4-800-6/-1,5 1,5 5,70 3,29 94CHGT/4-800-6/-2,2 2,2 8,23 4,75 99CHGT/4-800-6/-3 3 11,21 6,47 102CHGT/4-800-6/-4 4 – 8,18 114CHGT/4-800-6/-5,5 5,5 – 11,00 127CHGT/4-800-6/-7,5 7,5 – 14,20 141
CHGT/4-800-9/-2,2 2,2 8,04 4,64 117CHGT/4-800-9/-3 3 11,21 6,47 120CHGT/4-800-9/-4 4 – 7,62 132CHGT/4-800-9/-5,5 5,5 – 10,60 145CHGT/4-800-9/-7,5 7,5 – 14,20 159We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight
(Kg)230 V 400 VCHGT/4-900-6/-3 3 11,21 6,47 180CHGT/4-900-6/-4 4 – 8,18 188CHGT/4-900-6/-5,5 5,5 – 11,00 201CHGT/4-900-6/-7,5 7,5 – 14,20 215CHGT/4-900-6/-11 11 – 22,10 242CHGT/4-900-6/-15 15 – 29,10 270
CHGT/4-900-9/-4 4 – 9,50 181CHGT/4-900-9/-5,5 5,5 – 12,50 194CHGT/4-900-9/-7,5 7,5 – 16,00 208CHGT/4-900-9/-11 11 – 22,10 235CHGT/4-900-9/-15 15 – 29,10 263CHGT/4-900-9/-18,5 18,5 – 35,10 311
CHGT/4-1000-6/-4 4 – 8,18 175CHGT/4-1000-6/-5,5 5,5 – 11,00 188CHGT/4-1000-6/-7,5 7,5 – 14,20 202CHGT/4-1000-6/-11 11 – 22,10 229CHGT/4-1000-6/-15 15 – 29,10 257CHGT/4-1000-6/-18,5 18,5 – 35,10 305CHGT/4-1000-6/-22 22 – 41,00 306
CHGT/4-1000-9/-5,5 5,5 – 11,00 193CHGT/4-1000-9/-7,5 7,5 – 14,20 207CHGT/4-1000-9/-11 11 – 22,10 208CHGT/4-1000-9/-15 15 – 29,10 262CHGT/4-1000-9/-18,5 18,5 – 35,10 310CHGT/4-1000-9/-22 22 – 41,00 311
CHGT/4-1250-6/-15 15 – 29,10 414CHGT/4-1250-6/-18,5 18,5 – 35,10 462CHGT/4-1250-6/-22 22 – 41,00 463CHGT/4-1250-6/-30 30 – 56,00 523CHGT/4-1250-6/-37 37 – 67,40 624CHGT/4-1250-6/-45 45 – 81,60 670
CHGT/4-1250-9/-15 15 – 29,10 419CHGT/4-1250-9/-18,5 18,5 – 35,10 467CHGT/4-1250-9/-22 22 – 41,00 468CHGT/4-1250-9/-30 30 – 56,00 528CHGT/4-1250-9/-37 37 – 67,40 629CHGT/4-1250-9/-45 45 – 81,60 675
TECNICAl CHARACTERISTICS - MOTORS f400-120
CHGT 1 SPEED MODElSTECHNICAl CHARACTERISTICS - 4 POlES - 1450 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
Model Motor power(kW)
full load current(A)
Weight(Kg)
230 V 400 VCHGT/6-500-6/-0,55 0,55 2,79 1,61 45
CHGT/6-560-6/-0,55 0,55 2,79 1,61 64
CHGT/6-630-6/-0,55 0,55 2,79 1,61 69CHGT/6-630-6/-0,75 0,75 3,27 1,89 73CHGT/6-630-6/-1,1 1,1 5,27 3,04 76
CHGT/6-710-5/-0,55 0,55 2,79 1,61 80CHGT/6-710-5/-0,75 0,75 3,27 1,89 84CHGT/6-710-5/-1,1 1,1 5,27 3,04 87
CHGT/6-710-7/-1,5 1,5 6,75 3,90 93
CHGT/6-800-3/-0,55 0,55 2,79 1,61 83CHGT/6-800-3/-0,75 0,75 3,27 1,89 87CHGT/6-800-3/-1,1 1,1 5,27 3,04 90CHGT/6-800-3/-1,5 1,5 6,75 3,90 94
CHGT/6-800-6/-0,55 0,55 2,79 1,61 86CHGT/6-800-6/-0,75 0,75 3,27 1,89 90CHGT/6-800-6/-1,1 1,1 5,27 3,04 93CHGT/6-800-6/-1,5 1,5 6,75 3,90 97CHGT/6-800-6/-2,2 2,2 9,28 5,36 105
CHGT/6-800-9/-0,75 0,75 3,60 2,08 94CHGT/6-800-9/-1,1 1,1 5,07 2,93 97CHGT/6-800-9/-1,5 1,5 6,55 3,78 101CHGT/6-800-9/-2,2 2,2 9,28 5,36 109CHGT/6-800-9/-3 3 11,81 6,82 126
CHGT/6-900-6/-1,5 1,5 6,75 3,90 161CHGT/6-900-6/-2,2 2,2 9,28 5,36 169 CHGT/6-900-6/-3 3 11,81 6,82 186CHGT/6-900-6/-4 4 – 9,20 192
CHGT/6-900-9/-1,5 1,5 6,75 3,90 165CHGT/6-900-9/-2,2 2,2 9,28 5,36 173CHGT/6-900-9/-3 3 11,81 6,82 190CHGT/6-900-9/-4 4 – 9,20 196CHGT/6-900-9/-5,5 5,5 – 13,00 206We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight(Kg)
230 V 400 VCHGT/6-1000-6/-1,5 1,5 6,75 3,90 159CHGT/6-1000-6/-2,2 2,2 9,28 5,36 167CHGT/6-1000-6/-3 3 11,81 6,82 184CHGT/6-1000-6/-4 4 – 9,20 190CHGT/6-1000-6/-5,5 5,5 – 13,00 200CHGT/6-1000-6/-7,5 7,5 – 15,00 233
CHGT/6-1000-9/-2,2 2,2 9,28 5,36 172CHGT/6-1000-9/-3 3 11,81 6,82 189CHGT/6-1000-9/-4 4 – 9,20 195CHGT/6-1000-9/-5,5 5,5 – 13,00 205CHGT/6-1000-9/-7,5 7,5 – 15,00 238
CHGT/6-1250-6/-4 4 – 9,20 347CHGT/6-1250-6/-5,5 5,5 – 13,00 357CHGT/6-1250-6/-7,5 7,5 – 15,00 390CHGT/6-1250-6/-11 11 – 21,70 415CHGT/6-1250-6/-15 15 – 27,60 453
CHGT/6-1250-9/-5,5 5,5 – 13,00 362CHGT/6-1250-9/-7,5 7,5 – 15,00 395CHGT/6-1250-9/-11 11 – 21,70 420CHGT/6-1250-9/-15 15 – 27,60 458CHGT/6-1250-9/-18,5 18,5 – 36,10 508CHGT/6-1250-9/-22 22 – 41,40 530
TECHNICAl CHARACTERISTICS - MOTORS f400-120
CHGT 1 SPEED MODElSTECHNICAl CHARACTERISTICS - 6 POlES - 950 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
Model Motor power(kW)
full load current(A)
Weight(Kg)
V. 1 V. 2 V. 1 V. 2CHGT/4/8-800-6/-1,5/0,25 1,5 0,25 3,65 1,6 101CHGT/4/8-800-6/-2,2/0,37 2,2 0,37 4,7 1,66 109CHGT/4/8-800-6/-3/0,55 3 0,55 6,29 2,35 110CHGT/4/8-800-6/-4/0,75 4 0,75 8,44 2,25 117CHGT/4/8-800-6/-5,5/1,1 5,5 1,1 11,7 3,7 139CHGT/4/8-800-6/-7,5/1,5 7,5 1,5 15,9 4,72 152
CHGT/4/8-800-9/-2,2/0,37 2,2 0,37 4,7 1,66 113CHGT/4/8-800-9/-3/0,55 3 0,55 6,29 2,35 114CHGT/4/8-800-9/-4/0,75 4 0,75 8,44 2,25 121CHGT/4/8-800-9/-5,5/1,1 5,5 1,1 11,7 3,7 143CHGT/4/8-800-9/-7,5/1,5 7,5 1,5 15,9 4,72 156
CHGT/4/8-1000-9/-14/3,5 14 3,5 26,5 8,45 202CHGT/4/8-1000-9/-17/4,3 17 4,3 33,4 12,3 230CHGT/4/8-1000-9/-20/5 20 5 38,6 14,1 245
CHGT/4/8-1250-6/-14/3,5 14 3,5 26,5 8,45 424CHGT/4/8-1250-6/-17/4,3 17 4,3 33,4 12,3 452CHGT/4/8-1250-6/-20/5 20 5 38,6 14,1 467CHGT/4/8-1250-6/-30/8 30 8 52 18 525CHGT/4/8-1250-6/-37/9,2 37 9,2 74,2 25,4 650CHGT/4/8-1250-6/-44/11 44 11 80,2 27,2 715
CHGT/4/8-1250-9/-14/3,5 14 3,5 26,5 8,45 429CHGT/4/8-1250-9/-17/4,3 17 4,3 33,4 12,3 457CHGT/4/8-1250-9/-20/5 20 5 38,6 14,1 472CHGT/4/8-1250-9/-30/8 30 8 52 18 530CHGT/4/8-1250-9/-37/9,2 37 9,2 74,2 25,4 655CHGT/4/8-1250-9/-44/11 44 11 80,2 27,2 720
Model Motor power(kW)
full load current(A)
Weight(Kg)
V. 1 V. 2 V. 1 V. 2CHGT/4/8-400-6/-0,55/0,09 0,55 0,09 1,7 0,65 36
CHGT/4/8-450-6/-0,55/0,09 0,55 0,09 1,7 0,65 38
CHGT/4/8-500-6/-0,55/0,09 0,55 0,09 1,7 0,65 43CHGT/4/8-500-6/-0,75/0,12 0,75 0,12 1,86 0,84 49CHGT/4/8-500-6/-1,1/0,18 1,1 0,18 2,73 1,21 51
CHGT/4/8-560-6/-0,55/0,09 0,55 0,09 1,7 0,65 45CHGT/4/8-560-6/-0,75/0,12 0,75 0,12 1,86 0,84 51CHGT/4/8-560-6/-1,1/0,18 1,1 0,18 2,73 1,21 69CHGT/4/8-560-6/-1,5/0,25 1,5 0,25 3,65 1,6 79CHGT/4/8-560-6/-2,2/0,37 2,2 0,37 4,7 1,66 87
CHGT/4/8-630-6/-0,75/0,12 0,75 0,12 1,86 0,84 56CHGT/4/8-630-6/-1,1/0,18 1,1 0,18 2,73 1,21 74CHGT/4/8-630-6/-1,5/0,25 1,5 0,25 3,65 1,6 84CHGT/4/8-630-6/-2,2/0,37 2,2 0,37 4,7 1,66 92CHGT/4/8-630-6/-3/0,55 3 0,55 6,29 2,35 93
CHGT/4/8-710-5/-1,1/0,18 1,1 0,18 2,73 1,21 100CHGT/4/8-710-5/-1,5/0,25 1,5 0,25 3,65 1,6 103
CHGT/4/8-710-7/-2,2/0,37 2,2 0,37 4,7 1,66 105CHGT/4/8-710-7/-3/0,55 3 0,55 6,29 2,35 106CHGT/4/8-710-7/-4/0,75 4 0,75 8,44 2,25 113CHGT/4/8-710-7/-5,5/1,1 5,5 1,1 11,7 3,7 135
CHGT/4/8-800-3/-1,5/0,25 1,5 0,25 3,65 1,6 98CHGT/4/8-800-3/-2,2/0,37 2,2 0,37 4,7 1,66 106CHGT/4/8-800-3/-3/0,55 3 0,55 6,29 2,35 107CHGT/4/8-800-3/-4/0,75 4 0,75 8,44 2,25 114CHGT/4/8-800-3/-5,5/1,1 5,5 1,1 11,7 3,7 136We reserve right to supply different motors and hence data may change.
TECHNICAl CHARACTERISTICS - MOTORS f400-120
CHGT 2 SPEED MODElSTECHNICAl CHARACTERISTICS - 4/8 POlES - 1450/730 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
TECHNICAl CHARACTERISTICS - MOTORS f400-120
CHGT 2 SPEED MODElSTECHNICAl CHARACTERISTICS - 6/12 POlES - 950/475 RPM
Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency, etc.) match those of the intended electrical supply.
Model Motor power(kW)
full load current(A)
Weight(Kg)
V. 1 V. 2 V. 1 V. 2CHGT/6/12-500-6/-0,55/0,09 0,55 0,09 2,07 0,94 51
CHGT/6/12-560-6/-0,55/0,09 0,55 0,09 2,07 0,94 70
CHGT/6/12-630-6/-0,55/0,09 0,55 0,09 2,07 0,94 75CHGT/6/12-630-6/-0,75/0,12 0,75 0,12 2,28 1,02 77CHGT/6/12-630-6/-1,1/0,18 1,1 0,18 4,49 1,67 89
CHGT/6/12-710-5/-0,75/0,12 0,75 0,12 2,28 1,02 91
CHGT/6/12-710-7/-1,1/0,18 1,1 0,18 4,49 1,67 94CHGT/6/12-710-7/-1,5/0,25 1,5 0,25 4,24 1,67 97
CHGT/6/12-800-3/-0,55/0,09 0,55 0,09 2,07 0,94 89CHGT/6/12-800-3/-0,75/0,12 0,75 0,12 2,28 1,02 91CHGT/6/12-800-3/-1,1/0,18 1,1 0,18 4,49 1,67 103CHGT/6/12-800-3/-1,5/0,25 1,5 0,25 4,24 1,67 106CHGT/6/12-800-6/-0,55/0,09 0,55 0,09 2,07 0,94 86CHGT/6/12-800-6/-0,75/0,12 0,75 0,12 2,28 1,02 94CHGT/6/12-800-6/-1,1/0,18 1,1 0,18 4,49 1,67 106CHGT/6/12-800-6/-1,5/0,25 1,5 0,25 4,24 1,67 109CHGT/6/12-800-6/-2,2/0,37 2,2 0,37 5,9 2,3 110
CHGT/6/12-800-9/-0,75/0,12 0,75 0,12 2,28 1,02 98CHGT/6/12-800-9/-1,1/0,18 1,1 0,18 4,49 1,67 110CHGT/6/12-800-9/-1,5/0,25 1,5 0,25 4,24 1,67 113CHGT/6/12-800-9/-2,2/0,37 2,2 0,37 5,9 2,3 114CHGT/6/12-800-9/-3/0,55 3 0,55 8,87 3,80 126
CHGT/6/12-900-6/-1,1/0,18 1,1 0,18 4,49 1,67 174CHGT/6/12-900-6/-1,5/0,25 1,5 0,25 4,24 1,67 181CHGT/6/12-900-6/-2,2/0,37 2,2 0,37 5,9 2,3 191CHGT/6/12-900-6/-3/0,55 3 0,55 8,87 3,80 216CHGT/6/12-900-6/-4/0,65 4 0,65 10 3,5 210We reserve right to supply different motors and hence data may change.
Model Motor power(kW)
full load current(A)
Weight(Kg)
V. 1 V. 2 V. 1 V. 2CHGT/6/12-900-9/-1,5/0,25 1,5 0,25 4,24 1,67 185CHGT/6/12-900-9/-2,2/0,37 2,2 0,37 5,9 2,3 195CHGT/6/12-900-9/-3/0,55 3 0,55 8,87 3,80 220CHGT/6/12-900-9/-4/0,65 4 0,65 10 3,5 206CHGT/6/12-900-9/-6/1,2 6 1,2 14,4 5,5 262
CHGT/6/12-1000-6/-1,5/0,25 1,5 0,25 4,24 1,67 171CHGT/6/12-1000-6/-2,2/0,37 2,2 0,37 5,9 2,3 172CHGT/6/12-1000-6/-3/0,55 3 0,55 8,87 3,80 209CHGT/6/12-1000-6/-4/0,65 4 0,65 9,31 2,94 209CHGT/6/12-1000-6/-6/1,2 6 1,2 13,40 5,58 256
CHGT/6/12-1000-9/-2,2/0,37 2,2 0,37 5,73 2,18 177CHGT/6/12-1000-9/-3/0,55 3 0,55 8,87 3,80 214CHGT/6/12-1000-9/-4/0,65 4 0,65 9,31 2,94 214CHGT/6/12-1000-9/-6/1,2 6 1,2 13,40 5,58 261CHGT/6/12-1000-9/-7,5/1,5 7,5 1,5 16,40 6,49 268CHGT/6/12-1250-6/-4/0,65 4 0,65 9,31 2,94 365CHGT/6/12-1250-6/-6/1,2 6 1,2 13,40 5,58 413CHGT/6/12-1250-6/-7,5/1,5 7,5 1,5 16,40 6,49 390CHGT/6/12-1250-6/-9/1,8 9 1,8 18,90 7,08 445CHGT/6/12-1250-6/-12/2,4 12 2,4 23,40 8,07 506CHGT/6/12-1250-6/-17,5/4,3 17,5 3,5 40 14,5 538
CHGT/6/12-1250-9/-6/1,2 6 1,2 13,40 5,58 418CHGT/6/12-1250-9/-7,5/1,5 7,5 1,5 16,40 6,49 450CHGT/6/12-1250-9/-9/1,8 9 1,8 18,90 7,08 458CHGT/6/12-1250-9/-12/2,4 12 2,4 23,40 8,07 511CHGT/6/12-1250-9/-17/4,3 17,5 3,5 40 14,5 542CHGT/6/12-1250-9/-20/5 24 6 54,2 23,5 564
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
DIMENSIONS (mm)
D C
E
DF
A
B
Model A £ B C D E f
400 509 423 440 40 520 588
450 567,6 473 483 40 563 650
500 638 523 525 40 605 719
560 718,6 583 570 40 650 370
630 808 653 570 40 650 370
710 907,6 750 640 40 720 438
800 1007,6 850 640 40 720 438
Models 400 to 800
D DC
E
CF
G H
BA
80
D D
EBA
Model £ A £ B C D E f G H
900 1126,5 950 700 50 800 503 860 1076,5
1000 1256,5 1055 700 50 800 503 860 1206,5
1250 1476,5 1275 900 50 1000 310 1060 1426,5
Models 900 to 1250
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
MOuNTING ACCESSORIES
CVD CGT/CHGTProtection guards.Wire protection guards for mountingon the inlet or discharge sides of the cabinets.
PER-CN CHGTAluminium and sheet steel louvre back draft shutter (without bird guard) for CHGT and CGT series.
70
A
B
Model cabinet Inlet and discharge
Protection guard model A B
CHGT-400 CVD/400 CGT/CHGT 424 313,5
CHGT-450 CVD/450 CGT/CHGT 474 341,5
CHGT-500 CVD/500 CGT/CHGT 524 369,5
CHGT-560 CVD/560 CGT/CHGT 584 403,5
CHGT-630 CVD/630 CGT/CHGT 654 422,5
CHGT-710 CVD/710 CGT/CHGT 751 503,8
CHGT-800 CVD/800 CGT/CHGT 851,5 560,2
CHGT-900 CVD/900 CGT/CHGT 951,5 616,2
CHGT-1000 CVD/1000 CGT/CHGT 1056,5 675
CHGT-1250 CVD/1250 CGT/CHGT 1276,5 798,3
A (Interior measurement)
E
e70
NV = NUM. TAL Ø 4.1
NH = NUM. TAL Ø 4.1
Ø 4.1
Ø 4.1
E
e
10
10
Model A
400 428
450 478
500 528
560 585
630 655
710 752
800 852
900 952
1000 1057
1250 1277
A
B
130 Model cabinet A B
ACOP RECT CHGT/CGT 400 F400 428 428
ACOP RECT CHGT/CGT 450 F400 478 478
ACOP RECT CHGT/CGT 500 F400 528 528
ACOP RECT CHGT/CGT 560 F400 585 585
ACOP RECT CHGT/CGT 630 F400 655 655
ACOP RECT CHGT/CGT 710 F400 752 752
ACOP RECT CHGT/CGT 800 F400 852 852
ACOP RECT CHGT/CGT 900 F400 952 952
ACOP RECT CHGT/CGT 1000 F400 1057 1057
ACOP RECT CHGT/CGT 1250 F400 1277 1277
Dimensions in mm.
Dimensions in mm.
ACOP RECT CHGT/CGT f400Rectangular flexible connector.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
ExAMPlE Of SElECTING CHGT/ CGT fANS
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA
210-99 Standards.
CGT
Number of poles 4
Nominal diameter (mm) 1000
Number of blades 3
CGT/4-1000-3/_°-_ kW
Hz A B C
63 22 20 18
125 19 19 17
250 13 11 12
500 6 5 6
1000 4 5 5
2000 6 7 6
4000 11 13 12
8000 18 20 20
Table of correction factors for the calculation of the sound power level spectrum.
Spectrum sound power level
Hz dB(A) B lw dB(A)
63 95 20 75
125 95 19 76
250 95 11 84
500 95 5 90
1000 95 5 90
2000 95 7 88
4000 95 13 82
8000 95 20 75
Sound pressure spectrum
Hz dB(A) Atten. lw dB(A)
63 75 20 55
125 76 20 56
250 84 20 64
500 90 20 70
1000 90 20 70
2000 88 20 68
4000 82 20 62
8000 75 20 55
Working point:Airflow..................: 40,000 m3/hr = 11,1 m3/sPressure..: 23.4 mm c.a.
Taking as an example the following point: airflow axis (horizontal axis) at 40.000m3/h. (Airflow=11.1 m3/s) and at a static pressure of 23.4 mmWG (vertical axis at theleft side of the intersection).On those conditions the intersection point lies on the fan performance curve with 18º blade pitch angle (green line) with a dynamic pressure of 12.4 mmWG (red line)tracing at 40.000 m3/h point and clearly visible at upper vertical axis in the left side of the intersection).From this point, in the lower intersection that at 18º the absorbed power on the power scale on the left is 4768 W and that the upper red line corresponds, accordingto what can be read at the right lower side scale, to a motor power of 5,5 kW (S&P always recommends to work with a minimum security margin of 10% on theabsorbed power at the axis).Its total sound power level is 99 dB(A), (the sound level average value).The sound spectrum can be calculated from the noise area (the three areas delimited by grey lines): A, B, or C.In this case the working point is at the B area. To obtain the value of the spectrum for every octave band.For every eighth, the coefficient should be subtracted from the total sound power level.
At 3 meters of distance, the sound pressure level is 79 dB(A).
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
The resulting model would be CHGT/4-1000/3-16-5,5 kW.
BC
A
psf psf(Pa)
Pabs(W)15000
14000
13000
12000
10000
9000
8000
7000
6000
4000
3000
2000
10005000 15000 25000 35000 45000 55000
8º 10º12º
14º16º
18º20º 22º
24º 26º
28º
30º
32º
65000 75000
11000
(mmWG)
350
300
250
200
150
100
50
400
450
500
35
30
25
23,495
12,4
99
95 96 94 95 97
8º10º12º14º16º
18º
20º 22º 24º26º28º 30º32º
96 94 96 98 Lw dB(A)
989697101 100
40000
40000
4768
20
15
10
55000
2 4 6 8 10 12 14 16 18 20
15000 25000 35000 45000 55000
15
Absorbed power (W)
Recommended motorpower (kW)
11
5.5
7.5
43
65000 75000
40
45
50
qv [m3/h]
qv [m3/s]
qv [m3/h]
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 2 POlE MOTORS
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
CGT
Number of poles 2
Nominal diameter (mm) 400
Number of blades 6
CGT/2-400-6/_°-_ kW
Hz A B C
63 42 43 36
125 29 30 23
250 17 17 14
500 8 6 8
1000 4 4 5
2000 5 6 5
4000 9 10 8
8000 17 19 14
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
80
70
60
50
40
30
20
10
0
800
700
600
500
400
300
200
100
0
psf psf(Pa) (mmWG)
8°10°12°14°
16°
18° 34°32°30°28°26°24°
22°
20°
94 99 94 92 93
93
92 96 92 91 93
97 92 91 93 Lw dB(A)
1000
0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3
2000 3000 4000 5000 6000 7000 8000 9000 10000 qv [m3/h]
qv [m3/s]
Pabs (W )
2400
2000
1600
1200
800
400
01000 2000 3000 4000 5000 6000 7000 8000 9000 10000 qv [m3/h]
Absorbed power (W) motorRecommended
power (kW)
2.2
1.5
1.1
8° 10° 12° 14° 16° 18° 20°22° 24°
26°28°
30°32°
34°
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 2 POlE MOTORS
CGT
Number of poles 2
Nominal diameter (mm) 450
Number of blades 6
CGT/2-450-6/_°-_ kW
Hz A B C
63 42 43 36
125 29 30 23
250 17 17 14
500 8 6 8
1000 4 4 5
2000 5 6 5
4000 9 10 8
8000 17 19 14
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
90
80
70
60
50
40
30
20
10
0
900
800
700
600
500
400
300
200
100
0
3000
2500
2000
1500
1000
5001000 3000 5000 7000 9000 11000 13000
psf psf(Pa) (mmWG)
1000
0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6
qv [m3/h]
qv [m3/s]
3000 5000 7000 9000 11000 13000
8°10°12°14°
16°
18°
20°22°24°26° 28°
94
97
96 99 95 95
100 96 95 Lw dB(A)
102 98 97
Absorbed power (W) motorRecommended
power (kW)
2.2
1.5
3
28°
26°
24°22°
20°18°
16°14°12°
10°8°
qv [m3/h]
Pabs (W )
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 400
Number of blades 6
CHGT/4-400-6/_°-_ kWCGT/4-400-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
16
18
20
14
12
10
8
6
4
2
0
160
180
200
140
120
100
80
60
40
20
0
psf psf(Pa) (mmWG)
8º10º12º14º
16º
18º
20º22º
24º26º 28º30º32º34º36º38º
65 75 72 69 69 70
70 74 71 70 71
72 75 73 72 72 73
71 Lw dB(A)
0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
1000 2000 3000 4000 5000 6000 qv [m3/h]
qv [m3/s]
0.25
Pabs(W)300
250
200
150
100
50
00 1000 2000 3000 4000 5000 6000 qv [m3/h]
8º10º 12º 14º
16º 18º 20º22º
24º26º
28º
30º
32º
34º
36º
38º
motorRecommended
power (kW)Absorbed power (W)
(*) CGT Series only.CHGT Series motor 0,55.
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 450
Number of blades 6
CHGT/4-450-6/_°-_ kWCGT/4-450-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
A
B C16
18
20
22
24
26
14
12
10
8
6
4
2
0
160
180
200
220
240
260
140
120
100
80
60
40
20
0
psf psf(Pa) (mmWG)
8º10º 12º
14º
16º
18º
20º 24º 30º
38º
69 74 75 73 73 74
74
76 78 76 76 76 77
78 74 74 74 75 Lw dB(A)
10000
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2
2000 3000 4000 5000 6000 7000 8000 qv [m3/h]
qv [m3/s]
0.37
0.55
0.25
Pabs(W)600
550
500
450
400
350
300
250
200
150
100
50
0 1000 2000 3000 4000 5000 6000 7000 8000 qv [m3/h]
8º 10º12º
14º 16º18º
20º22º
24º26º
28º30º
32º
34º
36º38º
motorRecommended
power (kW)Absorbed power (W)
(*) CGT Series only.
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 500
Number of blades 6
CHGT/4-500-6/_°-_ kWCGT/4-500-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
A
B C16
18
20
22
24
26
28
30
14
12
10
8
6
4
2
0
160
180
200
220
240
260
280
300
140
120
100
80
60
40
20
0
psf psf(Pa) (mmWG)
8º
10º 12º14º
16º
18º
20º22º
24º26º 30º 32º
34º36º
38º
73 81 78 76 76 77
77778078
79 81 79 79 79 81
78 79 Lw dB(A)
1000
0.4 0.8 1.2 1.6 2 2.4 2.8 3.2
2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 qv [m3/h]
qv [m3/s]
Pabs(W)
1000
900
800
700
600
500
400
300
200
1001000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 qv [m3/h]
38º
36º
34º
32º
30º
28º26º
24º22º
20º18º16º14º12º
10º8º
1.1
0.75
0.55
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 560
Number of blades 6
CHGT/4-560-6/_°-_ kWCGT/4-560-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
C
A
B16
18
20
22
24
26
28
30
32
34
14
12
10
8
6
4
2
0
160
180
200
220
240
260
280
300
320
340
140
120
100
80
60
40
20
0
psf psf(Pa) (mmWG)
Pabs(W)
8º10º 12º 14º
16º
18º
20º22º
24º26º
28º30º
32º
34º
36º
38º81
8079838477
81 83 80 80 81
848382828483
83 Lw dB(A)
1000
0.5 1 1.5 2 2.5 3 3.5 4 4.5
3000 5000 7000 9000 11000 13000 15000 17000 qv [m3/h]
qv [m3/s]
2.2
1.5
1.1
0.75
0.55
38º
36º34º
32º30º
28º
26º24º
22º20º18º
16º14º12º10º8º
2000
1800
1600
1400
1200
1000
800
600
400
2001000 3000 5000 7000 9000 11000 13000 15000 17000 qv [m3/h]
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 630
Number of blades 6
CHGT/4-630-6/_°-_ kWCGT/4-630-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
A
B C
psf psf(Pa) (mmWG)
45045
40
35
30
25
20
15
10
5
0
400
350
300
250
200
150
100
50
0
8º
10º 12º14º
16º
18º
20º22º 24º
26º28º 30º
32º
34º
36º
38º
919088909387
89 91 87 87 89
908987878989
90 Lw dB(A)
2000
1 2 3 4 5 6 7
5000 8000 11000 14000 17000 20000 23000 26000 qv [m3/h]
qv [m3/s]
Absorbed power (W)Recommendedmotorpower (W)
Pabs(W)
3000
2000 5000 8000 11000 14000 17000 20000 23000 26000
2600
2200
1800
1400
1000
600
200qv [m3/h]
38º
36º
34º
32º
30º
28º
26º24º
22º20º
18º16º14º
12º10º8º
3
2.2
1.5
1.1
0.75
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT f300 / CGT
CHGT f300 / CGT
Number of poles 4
Nominal diameter (mm) 710
Number of blades 3
CHGT/4-710-3/_°-_ kWCGT/4-710-3/_°-_ kW
Hz A B C
63 22 22 22
125 19 19 19
250 13 13 13
500 6 6 6
1000 4 4 4
2000 6 6 6
4000 11 11 11
8000 18 18 18
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
A
B C
0 5000 10000 15000 20000 25000 30000
1 2 3 4 5 6 7 8
0
5
10
15
20
25
30
35
40
0
50
100
150
200
250
300
350
400
8°
14°
16°
18°
20°24°22°
26° 28° 30°32°
0 5000 10000 15000 20000 25000 300000
400
800
1200
1600
2000
2400
2800
3200
Pabs (W)
0.75
1.1
1.5
2.2
3
32°30°
28°26°
24°22°
20°18°16°
14°12°10°
8°
9189889092
91 LwdB(A)89889192
90919389
12°
10°
92
qv [m3/h]
psf psf(Pa)
qv [m3/h]
qv [m3/s]
Recommendedmotorpower (KW)Absorbed power (W)
(mmWG)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
A
B C
0 5000 10000 15000 20000 25000 30000
1 2 3 4 5 6 7 8
0
5
10
15
20
25
30
35
40
0
50
100
150
200
250
300
350
400
8°
14°
16°
18°
20°24°22°
26° 28° 30°32°
0 5000 10000 15000 20000 25000 300000
400
800
1200
1600
2000
2400
2800
3200
Pabs (W)
0.75
1.1
1.5
2.2
3
32°30°
28°26°
24°22°
20°18°16°
14°12°10°
8°
9189889092
91 LwdB(A)89889192
90919389
12°
10°
92
qv [m3/h]
psf psf(Pa)
qv [m3/h]
qv [m3/s]
Recommendedmotorpower (KW)Absorbed power (W)
(mmWG)
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT f300 / CGT
CHGT f300 / CGT
Number of poles 4
Nominal diameter (mm) 710
Number of blades 6
CHGT/4-710-6/_°-_ kWCGT/4-710-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 6 5 6
1000 5 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
A
B C
0 5000 10000 15000 20000 25000 30000
1 2 3 4 5 6 7 8
0
5
10
15
20
25
30
35
40
45
50
55
60
0
50
100
150
200
250
300
350
400
450
500
550
6008°
14°16°
18°
20°
24°
22°
26°28°30°32°
0 5000 10000 15000 20000 25000 300000
500
1000
1500
2000
2500
3000
3500
4000
Pabs (W)
1.1
1.5
2.2
3
4
32°30°
28°26°
24°22°
20°
18°16°14°12°
10°8°
9291919393
93 LwdB(A)91919493
92939691
12°10°
93
psf psf(Pa)
qv [m3/h]
qv [m3/h]
qv [m3/s]
Recommendedmotorpower (KW)Absorbed power (W)
(mmWG)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT f400
CHGT f400
Number of poles 4
Nominal diameter (mm) 710
Number of blades 5 or 7
CHGT/4-710-_/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 12 14 11
8000 18 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
AB
C
psf psf(Pa)
500
450
400
350
300
250
200
150
100
50
0
50
45
40
35
30
25
20
15
10
5
00 5000
1 2 3 4 5 6 7 8 9
10000 15000 20000 25000 30000 35000 qv [m3/h]
qv [m3/s]
Pabs (W)
5.5
4
3
2.2
1.5
1.1
5500
4500
3500
2500
1500
5000 5000 10000 15000 20000 25000 30000 35000 qv [m3/h]
38°
36°
34°
32°
30°28°
26°24°
22°20°18°16°
14°12°10°8°
8° 14°
16°
18°
20°22°26°24°
28°30°
32°34°
36°38°
898886889185
90 91 87 87 89
929189899192
90 LwdB(A)
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 800
Number of blades 3
CHGT/4-800-3/_°-_ kWCGT/4-800-3/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 12 14 11
8000 18 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
B
A
C
psf psf(Pa)
400
350
300
250
200
150
100
50
0
40
35
30
25
20
15
10
50
0
8°
10° 12°14°16°18°
20°22°
24° 26°28°
30°32°
87
92
94 91 90 91 93
90 88 89 91 Lw dB(A)
90 88 88 90
0 5000 10000 15000 20000 25000 30000 35000 40000
1 2 3 4 5 6 7 8 9 10 11
qv [m3/h]
qv [m3/s]
Pabs (W)
5.5
4
3
2.2
1.5
1.1
32°
30°
28°
26°24°
22°20°
18°16°
14°12°10°8°
5500
5000
4500
4000
3500
3000
2500
2000
1500
1000
5000 5000 10000 15000 20000 25000 30000 35000 40000 qv [m3/h]
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 800
Number of blades 6
CHGT/4-800-6/_°-_ kWCGT/4-800-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 12 14 11
8000 18 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
A
BC
psf psf(Pa)
600
550
500
450
400
350
300
250
200
150
100
50
0
60
55
50
45
40
35
30
25
20
15
10
5
00 5000 10000 15000 20000 25000 30000 35000 40000
12108642
45000
8° 14°
16°
18°
20°22°24°26°28°30° 32°
89 93
93
95 94 92 93 94
93 90 91 92 Lw dB(A)
90 90 91
qv [m3/h]
qv [m3/s]
Pabs (W )
7000
6000
5000
4000
3000
2000
10000 5000 10000 15000 20000 25000 30000 35000 40000 45000 qv [m3/h]
7.5
5.5
4
3
2.2
1.5
32°
30°
28°
26°24°
22°
20°18°
16°14°12°10°8°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 800
Number of blades 9
CHGT/4-800-9/_°-_ kWCGT/4-800-9/_°-_ kW
Hz A B C
63 40 38 32
125 26 19 19
250 14 9 11
500 6 5 7
1000 4 5 5
2000 7 7 6
4000 12 13 10
8000 20 21 17
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
60060
55
50
45
40
35
30
25
20
15
10
5
05000
2 4 6 8 10 12
10000 15000 20000 25000 30000 35000 40000 45000
550
500
450
400
350
300
250
200
150
100
50
0qv [m3/h]
qv [m3/s]
8° 14°16°
18°
20° 22° 24° 26° 28°30°
32°
90
94
96 96 93 93 95
95 91 91 93 Lw dB(A)
95 92 90 92
Pabs (W)
8000
7000
6000
5000
4000
3000
2000
10005000 10000 15000 20000 25000 30000 35000 40000 45000 qv [m3/h]
32°30°
28°
26°24°
22°20°
18°16°14°
12°10°8°
7.5
5.5
4
3
2.2
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 900
Number of blades 6
CHGT/4-900-6/_°-_ kWCGT/4-900-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
BA
C
psf psf(Pa)
70070
65
60
55
50
45
40
35
30
25
20
15
10
5
05000
2 4 6 8 10 12 14 16 18
15000 25000 35000 45000 55000 65000
650
550
600
500
450
400
350
300
250
200
150
100
50
0qv [m3/h]
qv [m3/s]
8° 14°
16°
18°
20°22°24°26° 28°30°
32°
95939397
97 96
99 97 95 96 98
93 94 96 Lw dB (A)
93
Pabs (W )
14000
13000
12000
11000
10000
9000
8000
7000
6000
5000
4000
3000
2000
10005000 15000 25000 35000 45000 55000 65000 qv [m3/h]
15
11
7.5
5.5
4
3
32°30°
28°
26°24°
22°20°
18°16°
14°12°10°8°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 900
Number of blades 9
CHGT/4-900-9/_°-_ kWCGT/4-900-9/_°-_ kW
Hz A B C
63 40 38 32
125 26 19 19
250 14 9 11
500 6 5 7
1000 4 5 5
2000 7 7 6
4000 12 13 10
8000 20 21 17
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CB
A
psf psf(Pa)
70070
65
60
55
50
45
40
35
30
25
20
15
10
5
0
650
600
550
500
450
400
350
300
250
200
150
100
50
0
8°10°12°14°16°
18°
20°22°
24°26°
28°30°32°
94
98
100 99 96 97 99
98 94 95 97 Lw dB (A)
98 95 94 96
5000
2 4 6 8 10 12 14 16 18
15000 25000 35000 45000 55000 65000 qv [m3/h]
qv [m3/s]
16000
14000
12000
10000
8000
6000
4000
20005000 15000 25000 35000 45000 55000 65000
Pabs (W )
qv [m3/h]
32°
30°
28°26°
24°22°
20°18°
16°
14°12°10°8°
15
11
7.5
5.5
4
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
Pabs (W)
16000
14000
12000
10000
8000
6000
4000
2000
18000
5000 15000 25000 35000 45000 55000 65000 qv [m3/h]
motorRecommended
power (kW)Absorbed power (W)
18.5
15
11
7.5
5.5
48° 10° 12° 14°
16°18°
20°22°
24°26°
28°30°
32°
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 1000
Number of blades 6
CHGT/4-1000-6/_°-_ kWCGT/4-1000-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
850
800
750
550
600
650
700
500
450
400
350
300
200
150
100
250
50
85
80
75
55
60
65
70
50
45
40
35
30
20
15
10
25
5
96 99 96 96 98
101 99 96 97
103 100 98 99 101
100 Lw dB (A)
10000
3 5 7 9 11 13 15 17 19 21
20000 30000 40000 50000 60000 70000 80000 qv [m3/h]
qv [m3/s]
Pabs (W )
21000
19000
17000
15000
13000
11000
9000
7000
5000
3000
100010000 20000 30000 40000 50000 60000 70000 80000 qv [m3/h]
32°30°
28°
26°24°
22°20°
18°16°
14°12°10°8°
22
18.5
15
11
7.5
5.54
8°
10°12°
14°
16°
18°
20° 22° 24° 26° 28° 30° 32°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 1000
Number of blades 9
CHGT/4-1000-9/_°-_ kWCGT/4-1000-9/_°-_ kW
Hz A B C
63 40 38 32
125 26 19 19
250 14 9 11
500 6 5 7
1000 4 5 5
2000 7 7 6
4000 12 13 10
8000 20 21 17
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
850
800
750
550
600
650
700
500
450
400
350
300
200
150
100
250
50
85
80
75
55
60
65
70
50
45
40
35
30
20
15
10
25
510000 20000 30000 40000 50000 60000 70000 80000 90000
4 6 8 10 12 14 16 18 20 22 24
qv [m3/h]
qv [m3/s]
97 101 98 97 99
102 101 97 98 100 Lw dB (A)
104 102 99 100 102
8°10°12°14°
16°
18°
20°22°24° 26° 28°30° 32°
Pabs (W )26000
22000
18000
14000
10000
6000
200010000 20000 30000 40000 50000 60000 70000 80000 90000 qv [m3/h]
32°
30°
28°
26°24°
22°20°
18°16°
14°12°10°8°
22
18.5
15
11
7.5
5.5
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 1250
Number of blades 6
CHGT/4-1250-6/_°-_ kWCGT/4-1250-6/_°-_ kW
Hz A B C
63 38 38 31
125 22 21 19
250 12 9 12
500 5 5 6
1000 4 5 5
2000 7 8 6
4000 13 14 11
8000 21 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
95095
850
750
650
550
450
350
250
150
50 5
15
25
35
45
55
65
75
85 8°
10°12°14°
16°
18°
20°22°
24°26° 28°30° 32°
104
104 107 Lw dB (A)109
105
105
102
102
106 108110 106 104
103 105
20000
6 10 14 18 22 26 30 34 38 42
40000 60000 80000 100000 120000 140000 160000 qv [m3/h]
qv [m3/s]
Pabs(W)
48000
44000
40000
36000
32000
28000
24000
20000
16000
12000
800020000 40000 60000 80000 10000 120000 140000 160000 qv [m3/h]
32º
30º28º
26º
24º
22º
20º
18º
16º
14º12º10º8º
45
37
30
22
18.5
15
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 4 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 4
Nominal diameter (mm) 1250
Number of blades 9
CHGT/4-1250-9/_°-_ kWCGT/4-1250-9/_°-_ kW
Hz A B C
63 40 38 32
125 26 19 19
250 14 9 11
500 6 5 7
1000 4 5 5
2000 7 7 6
4000 12 13 10
8000 20 21 17
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
B
A
C
psf psf(Pa)
1250125
115
105
95
85
75
65
55
45
35
25
15
5
1150
1050
950
850
750
650
550
450
350
250
150
50
8°10°12°14°
16°
18°
20° 22° 24°
104 105 102 103
105109
110 106 104 106
102 104 Lw dB(A)
20000
8 12 16 20 24 28 32 36 40 44
40000 60000 80000 100000 120000 140000 160000 qv [m3/h]
qv [m3/s]
Pabs(W)
20000 40000 60000 80000 100000 120000 140000 160000
45
37
30
22
18.5
15
24°
22°
20°
18°16°
14°12°
10°
8°
qv [m3/h]
(mmWG)
motorRecommended
power (kW)Absorbed power (W)45000
40000
35000
30000
25000
20000
15000
10000
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 500
Number of blades 6
CHGT/6-500-6/_°-_ kWCGT/6-500-6/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 15 16 13
8000 23 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CB
A
9
10
11
12
8
7
6
5
4
3
2
1
0
90
100
110
120
80
70
60
50
40
30
20
10
0
psf psf(Pa) (mmWG)
qv [m3/h]
qv [m3/s]
8°10°12°14°
16°
18°
20°24° 28° 32°34°
36°38°
62 70 68 66
66 69 69 Lw dB(A)67 67 67
716969697068
66 67
0
0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4
1000 2000 3000 4000 5000 6000 7000 90008000
Pabs (W )350
300
250
200
150
100
00 1000 2000 3000 4000 5000 6000 7000 8000 9000
50
qv [m3/h]
0.37
38°
36°
34°32°
30°28°
26°24°
22°20°18°16°14°12°10°8°
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 560
Number of blades 6
CHGT/6-560-6/_°-_ kWCGT/6-560-6/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 15 16 13
8000 23 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa) (mmWG)
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
8°10°12°
14°
16°
18°
20°22°
24°26°
28°30°32°
34°
36°
38°66 73 71 69 70
70 72 7071 71
747372727372
72 Lw dB(A)
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
0.4 0.8 1.2 1.6 2 2.4 2.8 3.2
qv [m3/h]
qv [m3/s]
Pabs (W )
600
500
400
300
200
100
0
0.55
0.37
38°36°
34°32°
30°28°
26°24°
22°20°
18°16°14°12°10°8°
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 qv [m3/h]
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 630
Number of blades 5
CHGT/6-630-6/_°-_ kWCGT/6-630-6/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 15 16 13
8000 23 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
18
20
16
14
12
10
8
6
4
2
0
180
200
160
140
120
100
80
60
40
20
0
psf psf(Pa) (mmWG)
8°
10°12°14°
16°
18°
20°22°24°26°
28°30°32°
34°
36°
38°70 76
76
76 76 76 76 76 78
76 74 74 75 76 Lw dB(A)
76 73 73
1000
0.5 1 1.5 2 2.5 3 3.5 4 4.5
3000 5000 7000 9000 11000 13000 15000 17000 qv [m3/h]
qv [m3/s]
motorRecommended
power (kW)Absorbed power (W)Pabs (W )
1000
900
800
700
600
500
400
300
200
100
01000 3000 5000 7000 9000 11000 13000 15000 17000 qv [m3/h]
1.1
0.75
0.55
0.37
38°
36°
34°
32°30°
28°26°
24°22°
20°18°16°
14°12°10°8°
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT f300 / CGT
CHGT f300 / CGT
Number of poles 6
Nominal diameter (mm) 710
Number of blades 3
CHGT/6-710-3/_°-_ kWCGT/6-710-3/_°-_ kW
Hz A B C
63 25 25 25
125 17 17 18
250 9 9 9
500 5 5 5
1000 5 5 5
2000 9 9 9
4000 14 15 15
8000 22 22 22
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
0 4000 8000 12000 16000 20000
1 2 3 4 5
0
2
4
6
8
10
12
14
16
18
0
20
40
60
80
100
120
140
160
180
8°
14°
16°
18°
20°24°
22°26° 28° 30° 32°
0 4000 8000 12000 16000 200000
200
400
600
800
1000
Pabs (W )
0.55
0.7532°
30°
28°26°
24°22°
20°18°
16°14°12°
10°8°
8180787981
81 LwdB(A)80788081
81818278
12°
10°
82
psf psf(Pa)
qv [m3/h]
qv [m3/h]
qv [m3/s]
Recommendedmotorpower (KW)Absorbed power (W)
(mmWG)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT f300 / CGT
CHGT f300 / CGT
Number of poles 6
Nominal diameter (mm) 710
Number of blades 6
CHGT/6-710-6/_°-_ kWCGT/6-710-6/_°-_ kW
Hz A B C
63 33 32 33
125 16 15 15
250 8 7 8
500 5 4 5
1000 5 4 5
2000 10 10 10
4000 17 16 16
8000 25 25 25
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
0 4000 8000 12000 16000 20000
1 2 3 4 5
0
5
10
15
20
25
0
50
100
150
200
2508° 14°16°
18°
20°
24°
22°
26°28°30° 32°
0 4000 8000 12000 16000 200000
200
400
600
800
1000
1200
Pabs (W )
0.55
0.75
1.1
Recommendedmotorpower (KW)Absorbed power (W)
32°
30°
28°26°
24°
22°20°
18°16°
14°12°
10°8°
8281818282
83 LwdB(A)81818382
82838580
12°10°
83
psf psf(Pa) (mmWG)
qv [m3/h]
qv [m3/h]
qv [m3/s]
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
CBA
0 4000 8000 12000 16000 20000
1 2 3 4 5
0
5
10
15
20
25
0
50
100
150
200
2508° 14°16°
18°
20°
24°
22°
26°28°30° 32°
0 4000 8000 12000 16000 200000
200
400
600
800
1000
1200
Pabs (W )
0.55
0.75
1.1
Recommendedmotorpower (KW)Absorbed power (W)
32°
30°
28°26°
24°
22°20°
18°16°
14°12°
10°8°
8281818282
83 LwdB(A)81818382
82838580
12°10°
83
psf psf(Pa) (mmWG)
qv [m3/h]
qv [m3/h]
qv [m3/s]
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT
CHGT
Number of poles 6
Nominal diameter (mm) 710
Number of blades 5 or 7
CHGT/6-710-_/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 13 16 13
8000 19 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CB
A
psf psf(Pa)
24024
20
16
12
8
4
00
0 1 2 3 4 5
3000 6000 9000 12000 15000 18000 21000
200
160
120
80
40
0qv [m3/h]
qv [m3/s]
74 80 78 77
77
81 8180 8079
78
78 79 Lw dB(A)79 79
8°
18°
14°
16°
20°22°24°26°28°
30°32°
Pabs (W )
1500
1300
1100
900
700
500
300
1000 3000 6000 9000 12000 15000 18000 21000 qv [m3/h]
1.5
1.1
0.75
0.55
32°30°
28°
26°24°
22°20°
18°16°14°12°10°8°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 800
Number of blades 3
CHGT/6-800-3/_°-_ kWCGT/6-800-3/_°-_ kW
Hz A B C
63 25 25 22
125 19 17 18
250 11 9 10
500 6 5 6
1000 4 5 4
2000 8 9 8
4000 13 14 14
8000 20 22 23
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CB
A
psf psf(Pa)
18018
16
14
12
10
8
6
4
2
00
0 1 2 3 4 5 6 7
4000 8000 12000 16000 20000 24000 28000
160
140
120
100
80
60
40
20
0qv [m3/h]
qv [m3/s]
81
83 80 80 81 83
7879
76 78 78 8079
79 81 Lw dB(A)
8°10°12°14°16°
18°
20°22° 24°
26°28°
30°32°
Pabs (W )
1500
1250
1000
750
500
250
00 4000 8000 12000 16000 20000 24000 28000 qv [m3/h]
32°
30°
28°
26°
22°24°
20°18°
16°14°12°10°8°
1.5
1.1
0.75
0.55
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 800
Number of blades 6
CHGT/6-800-6/_°-_ kWCGT/6-800-6/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 15 16 13
8000 23 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CB
A
psf psf(Pa)
300
250
200
150
100
50
0
30
25
20
15
10
5
00
0 1 2 3 4 5 6 7
4000 8000 12000 16000 20000 24000 28000 qv [m3/h]
qv [m3/s]
8°
10°12° 14°
16°
18°
20°22°24° 26°28°30°32°
78 80 80 81
81 82 Lw dB(A)82
84 83 82 83 84
82 80
82
Pabs (W )
2.2
1.5
1.1
0.75
0.55
32°
30°
28°
26°
22°
24°
20°18°
16°14°12°10°
8°
0 4000 8000 12000 16000 20000 24000 28000
2200
2000
1800
1600
1400
1200
1000
800
600
400
200qv [m3/h]
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 800
Number of blades 9
CHGT/6-800-9/_°-_ kWCGT/6-800-9/_°-_ kW
Hz A B C
63 37 31 29
125 22 15 16
250 11 8 10
500 5 5 6
1000 4 5 5
2000 9 9 7
4000 14 15 11
8000 22 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
300
250
200
150
100
50
0
30
25
20
15
10
5
02000
1 2 3 4 5 6 7 8
5000 8000 11000 14000 17000 20000 23000 26000 29000 qv [m3/h]
qv [m3/s]
8° 14°
16°
18°
20° 22° 24° 26° 28°30° 32°
79 82 82
83 84 82 82
85 85 83 84 85
83 Lw dB(A)
8184
Pabs (W )
3
2.2
1.5
1.1
0.75
32°
30°
28°26°
22°24°
20°18°
16°14°12°10°8°
2800
2400
2000
1600
1200
800
4002000 5000 8000 11000 14000 17000 20000 23000 26000 29000 qv [m3/h]
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 900
Number of blades 6
CHGT/6-900-6/_°-_ kWCGT/6-900-6/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 15 16 13
8000 23 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
360
320
280
240
120
160
200
40
80
0
36
32
28
24
12
16
20
4
8
02000
1 2 3 4 5 6 7 8 9 10 11
6000 10000 14000 18000 22000 26000 30000 34000 38000 42000 qv [m3/h]
qv [m3/s]
8° 14°10°12°
16°
18°
20°22°24°26°28°30° 32°
82
86
88 86 85 86 88
85 83 84 86 Lw dB(A)
83 858386
Pabs (W )
4000
3500
3000
2500
2000
1500
1000
500
02000 6000 10000 14000 18000 22000 26000 30000 34000 38000 42000 qv [m3/h]
4
3
2.2
1.5
32°
30°
28°
26°22° 24°
20°18°
16°14°
12°10°8°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 900
Number of blades 9
CHGT/6-900-9/_°-_ kWCGT/6-900-9/_°-_ kW
Hz A B C
63 37 31 29
125 22 15 16
250 11 8 10
500 5 5 6
1000 4 5 5
2000 9 9 7
4000 14 15 11
8000 22 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
C
BA
psf psf(Pa)
360
320
280
240
120
160
200
40
80
0
36
32
28
24
12
16
20
4
8
0
8° 14°10°12°
16°
18°
20°22°
24°26°28°30°32°
83 85 85
85858787
87 89878889
87 Lw dB(A)
8487
5000
2 3 4 5 6 7 8 9 10 11 12
10000 15000 20000 25000 30000 35000 40000 45000 qv [m3/h]
qv [m3/s]
Pabs (W )
5500
5000
4500
4000
3500
3000
2000
2500
1500
1000
5005000 10000 15000 20000 25000 30000 35000 40000 45000 qv [m3/h]
32°30°
28°26°
22° 24°20°
18°16°
14°12°10°8°
5.5
4
3
2.2
1.5
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 1000
Number of blades 6
CHGT/6-1000-6/_°-_ kWCGT/6-1000-6/_°-_ kW
Hz A B C
63 22 20 18
125 19 19 17
250 13 11 12
500 6 5 6
1000 4 5 5
2000 6 7 6
4000 11 13 12
8000 18 20 12
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CBA
psf psf(Pa)
380
340
300
260
140
180
220
60
100
20
38
34
30
26
14
18
22
6
10
25000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000
2 3 4 5 6 7 8 9 10 11 12 13 14 15
qv [m3/h]
qv [m3/s]
85 86 888688
90 86 89 Lw dB(A)8588
92 88 89 9189
8° 14°10°12°
16°
18°
20° 22° 24° 26° 28° 30° 32°
Pabs (W )
7000
6000
5000
4000
3000
2000
1000
05000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000 qv [m3/h]
5.5
4
3
2.2
1.5
7.5
32°30°
28°26°
22°24°
20°18°
16°14°12°10°8°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 1000
Number of blades 9
CHGT/6-1000-9/_°-_ kWCGT/6-1000-9/_°-_ kW
Hz A B C
63 37 31 29
125 22 15 16
250 11 8 10
500 4 5 6
1000 4 5 5
2000 9 9 7
4000 14 15 11
8000 22 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
C
BA
psf psf(Pa)
380
340
300
260
140
180
220
100
60
20
38
34
30
26
14
18
22
10
6
210000
3 5 7 8 11 13 15
15000 20000 25000 30000 35000 40000 45000 50000 55000 60000 qv [m3/h]
qv [m3/s]
8°
10°12°14°
16°
18°
20° 22° 24° 26°28° 30° 32°
86 88 898790
91 88 90 Lw dB(A)8890
93 89 90 9291
Pabs (W )
7000
6000
5000
4000
3000
2000
100010000 15000 20000 25000 30000 35000 40000 45000 50000 55000 60000 qv [m3/h]
5.5
4
3
2.2
7.5
32°
30°
28°
26°
22°24°
20°18°
16°14°
12°10°8°
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 1250
Number of blades 6
CHGT/6-1250-6/_°-_ kWCGT/6-1250-6/_°-_ kW
Hz A B C
63 33 33 28
125 18 15 18
250 9 8 10
500 5 5 5
1000 5 5 5
2000 8 10 7
4000 15 16 13
8000 23 25 21
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
CB
A
psf psf(Pa)
460
420
380
340
220
260
300
180
140
100
60
20
46
42
38
34
22
26
30
18
14
10
6
210000
4 6 8 10 12 14 16 18 20 22 24 26 28 30
20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 qv [m3/h]
qv [m3/s]
8°10°12°14°
16°
18°
20°22°24°
26° 28°30° 32°
93 92 959394
97
99 95 94 96 98
92 94 96 Lw dB(A)94
Pabs (W )14000
10000
12000
8000
4000
6000
200010000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 qv [m3/h]
32°
30°28°
26°
22°
24°
20°18°
16°
14°12°10°8°
15
11
7.5
5.5
4
(mmWG)
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
www.solerpalau.com
AXIAL FLOW CABINET FANSCHGT Series
Cylindrical cased axial flow fans CHGT
PERfORMANCE CuRVES - 6 POlE MOTORS - CHGT / CGT
CHGT / CGT
Number of poles 6
Nominal diameter (mm) 1250
Number of blades 9
CHGT/6-1250-9/_°-_ kWCGT/6-1250-9/_°-_ kW
Hz A B C
63 37 31 29
125 22 15 16
250 11 8 10
500 5 5 6
1000 4 5 5
2000 9 9 7
4000 14 15 11
8000 22 23 19
Table of correction factors for the calculation of the sound power level spectrum.
THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES CORRESPOND TO SOUND POWER LEVELS LwA.
TO CONVERT THIS DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT REDUCTION DUE TO DISTANCE.
AB
C
psf psf(Pa) (mmWG)
580
540
380
340
500
300
460
260
140
180
420
220
100
60
20
58
54
38
34
50
30
46
26
14
18
42
22
10
6
2
2
1000020000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000
6 8 10 12 14 16 18 20 22 24 26 28 30 32
qv [m3/h]
qv [m3/s]
10°8° 12°14°
16°
18°
20° 22° 24° 26°28°30°32°
94 94 96
98 96
94
94
100 97 97 9995
95 97 Lw dB(A)
96
Pabs (W )
22000
20000
20000 30000 40000 50000 60000 70000 80000 90000 100000110000 120000
18000
16000
12000
14000
10000
100002000
6000
8000
4000
qv [m3/h]
32°30°
28°26°
22°24°
20°18°
16°14°
12°10°8°
22
18.5
15
11
7.5
5.5
motorRecommended
power (kW)Absorbed power (W)
- qv: Air volume in m3/h and m3/s.- psf: Static pressure in mmWG and Pa.– Dry air at 20ºC and 760 mmHg.– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.