awake animal spect: overview and initial results o ak r idge n ational laboratory u.s. department of...

6
Awake Animal SPECT: Overview and Initial Results OAK RIDGE NATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1 , Brian Kross 1 , Stan Majewski 1 , John McKisson 1 , Vladimir Popov 1 , James Proffitt 1 , Sasha Stolin 1 , Justin Baba 2 , Jim Goddard 2 , Mark Smith 4 ,Ben Tsui 3 and Martin Pomper 3 1 Thomas Jefferson National Accelerator Facility, 2 Oak Ridge National Laboratory, 3 Johns Hopkins University, 4 University of Maryland.

Upload: melinda-flynn

Post on 20-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Awake Animal SPECT: Overview and Initial Results O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1, Brian Kross 1, Stan Majewski

Awake Animal SPECT: Overview and Initial Results

OAK RIDGE NATIONAL LABORATORY

U.S. DEPARTMENT OF ENERGY

U.S. DEPARTMENT OF ENERGY

Drew Weisenberger1, Brian Kross1, Stan Majewski1, John McKisson1, Vladimir Popov1, James Proffitt1, Sasha Stolin1, Justin Baba2, Jim Goddard2, Mark Smith4,Ben Tsui3 and Martin Pomper3

1Thomas Jefferson National Accelerator Facility, 2Oak Ridge National Laboratory, 3Johns Hopkins University, 4University of Maryland.

Page 2: Awake Animal SPECT: Overview and Initial Results O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1, Brian Kross 1, Stan Majewski

SPECT camera

Infrared Tracking System

Awake Animal SPECT-CT Imaging System

An awake mouse with infrared reflectors for head tracking shown in imaging burrow.

Computer display illustrating real-time pose tracking via the stereo infrared CCD cameras.

Page 3: Awake Animal SPECT: Overview and Initial Results O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1, Brian Kross 1, Stan Majewski

SPECT camera

SPECT camera data and voltage cables

• Accommodate analog signals from two gamma cameras • Need to incorporate time stamp event by event• Software controlled high voltage to gamma cameras• Elimination of long signal wires by employing fiber optic USB2 repeater

SPECT Data Acquisition System Modifications

Page 4: Awake Animal SPECT: Overview and Initial Results O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1, Brian Kross 1, Stan Majewski

SPECT cameras

JLab FPGA data acquisition system

USB-fiber optic

Infrared Tracking System

mouse in burrow

Page 5: Awake Animal SPECT: Overview and Initial Results O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1, Brian Kross 1, Stan Majewski

Tc99m-MDP

SPECT Scan of Awake Mouse

Movie of Multiple SPECT Projections

Page 6: Awake Animal SPECT: Overview and Initial Results O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Drew Weisenberger 1, Brian Kross 1, Stan Majewski