auxiliary...australia bms module ® pump control auxiliary equipment pump 2 fault pump 1 fault high...
TRANSCRIPT
Auxiliary
Section 3
Australia
®
BMS ModulePump Control Auxiliary Equipment
PU
MP
2FA
ULT
PU
MP
1FA
ULT
HIG
HL
EV
EL
AL
AR
M
PO
WE
RFA
ILU
RE
PO
WE
R IN
9-12V A
C/D
CD
ATA
IN
BMS MODULE
A unique feature of the FPC-300 Dual Pump Control-ler is the coded Data Output, which can be utilized to provide a signal to a remote, compatible device such as this BMS Module. The unique feature is that the coded data signal, derived from the Pump Controller’s micro processor, is conveyed through a low voltage, 2 wire connection and then decoded by the BMS Module micro controller. Once the signal is decoded the micro controller provides four voltage free relay outputs for interfacing with a computer or other monitoring equip-ment. An additional feature of the BMS Module is the inclusion of indicator lights on the circuit board, which can be viewed through the clear enclosure lid, indicat-ing relay ‘switched’ status. The module operates on 9 - 12V ac/dc and is supplied complete with power pack.
FPC-30110
PUM
P 2FA
ULT
PUM
P 1FA
ULT
HIG
HLEVEL
ALA
RM
POW
ERFA
ILUR
E
POW
ER IN
9-12V AC
/DC
DATAIN
BMS MODULE
MODESELECT
INPUT2INPUT14-20mA
+ -INPUT3 INPUT4 BMS/
REMOTESTROBE
- +SIREN- +
POWER12Vac
PUMP 1 PUMP 2PUMP 2FAULT
PUMP 1FAULT
KEYPAD CONNECTION PIN 1
500mA
DUAL PUMPCONTROLLERCOM-30089
240V 10A MAX
Australia
®
IMPORTANT: READ INSTALLTION AND OPERATION MANUAL BEFORE USE
Wiring
Kit IncludesBMS Control CardPower PackPolycarbonate Enclosure with Clear Lid
PU
MP
2FA
ULT
PU
MP
1FA
ULT
HIG
HL
EV
EL
AL
AR
M
PO
WE
RFA
ILU
RE
PO
WE
R IN
9-12V A
C/D
CD
ATA
IN
BMS MODULE
85m
m
125mm 55mm
2 WireConnection
For Connection to Monitoring Device
(by others)
Two core communication cableDistance between pump controller and BMS Module - up to 150 meters
Building Management System - BMS Module
FPC-30110
Section 3
Australia
®
Remote Status Indicator-Dual PumpPump Control Auxiliary Equipment
A unique feature of the FPC-300 Dual Pump Controller is the coded Data Output, which can be utilized to provide a signal to a remote, compatible device such as this Remote Status Indicator. The unique feature is that the coded data signal, derived from the Pump Controller’s micro processor, is conveyed through a low voltage 2 wire connection and then decoded by the Remote Status Indicator’s micro controller. Once the signal is decoded the micro controller provides four outputs to LED’s and a Buzzer mounted on the circuit board. Conditions displayed by the remote indicator include ‘power on’, ‘high level’, ‘pump 1 fault’ and ‘pump 2 fault’. The indoor indicator is mounted on an attractive wall plate, which incor-porates the four indicator lights, plus the buzzer and mute button.
As soon as an alarm condition occurs at the pump station, the appropriate LED on the indicator is illuminated and the Buzzer starts to sound. The Buzzer will automatically silence after 5 minutes. The Buzzer can also be muted by way of the Mute button. The Alarm light will remain illuminated until the fault condition is remedied.
Remote Status IndicatorS
IGN
AL
IN
MATelec
REM
OTE STATU
SIN
DIC
ATOR
MODESELECT
INPUT2INPUT14-20mA
+ -INPUT3 INPUT4 BMS/
REMOTESTROBE
- +SIREN- +
POWER12Vac
PUMP 1 PUMP 2PUMP 2FAULT
PUMP 1FAULT
KEYPAD CONNECTION PIN 1
500mA
DUAL PUMPCONTROLLERCOM-30089
240V 10A MAX
Australia
®
IMPORTANT: READ INSTALLTION AND OPERATION MANUAL BEFORE USE
Wiring
The wall mount display is the size of a typical light switch, featuring sub-surface LED’s and Mute button. The use of a UV stabilized membrane overlay, ensures a long lasting ‘new look’ is maintained.
Indoor Wall Mount Display
No external power source required
2 WireConnection
Standard Switch Plate Size
117m
m
73mm
Mounting PlatePCB Plaster BracketMounting Screws
Kit Includes
Two core communication cableDistance between pump controller and RSI - up to 150 meters
FPC-30100
FPC-30100
Section 3
Australia
®
Remote Status Indicator-Single PumpPump Control Auxiliary Equipment
Level Alarm
Pump Fault
A unique feature of the FPC-1500 Single Pump Controller is the coded Data Output, which can be utilized to provide a signal to a remote, compatible device such as this Remote Status Indicator. The unique feature is that the coded data signal, derived from the Pump Controller’s micro processor, is conveyed through a low voltage 2 wire connection and then decoded by the Remote Status Indica-tor’s micro controller. Once the signal is decoded the micro controller provides three outputs to LED’s and a Buzzer mounted on the circuit board. Conditions displayed by the remote indicator include ‘power on’, ‘high level’ and ‘pump fault’. The indoor indicator is mounted on an attractive wall plate, which incorporates the four indicator lights, plus the buzzer and mute button.
As soon as an alarm condition occurs at the pump station, the appropriate LED on the indicator is illuminated and the Buzzer starts to sound. The Buzzer will automatically silence after 5 minutes. The Buzzer can also be muted by way of the Mute button. The Alarm light will remain illuminated until the fault condition is remedied.
Remote Status Indicator
Level Alarm
Pump Fault
SIG
NA
LIN
MATelec
REM
OTE STATU
SIN
DIC
ATOR
MODESELECT
INPUT2INPUT14-20mA
+ -INPUT3 INPUT4 BMS/
REMOTESTROBE
- +SIREN- +
POWER12Vac
PUMP 1 PUMP 2PUMP 2FAULT
PUMP 1FAULT
KEYPAD CONNECTION PIN 1
500mA
DUAL PUMPCONTROLLERCOM-30089
240V 10A MAX
Australia
®
IMPORTANT: READ INSTALLTION AND OPERATION MANUAL BEFORE USE
Wiring
The wall mount display is the size of a typical light switch, featuring sub-surface LED’s and Mute button. The use of a UV stabilized membrane overlay, ensures a long lasting ‘new look’ is maintained.
Indoor Wall Mount Display
No external power source required
2 WireConnection
Standard Switch Plate Size
117m
m
73mm
Mounting PlatePCB Plaster BracketMounting Screws
Kit Includes
Two core communication cableDistance between pump controller and RSI - up to 150 meters
FPC-15100
FPC-15100
Section 3
FPC-15100
Australia
®
SMS Alarm SenderPump Control Auxiliary Equipment
A unique feature of the FPC-300 Dual Pump Controller is the coded Data Output, which can be utilized to provide a signal to a remote, compatible device such as this SMS Alarm Sender. The unique feature is that the coded data signal, derived from the Pump Controller’s micro processor, is conveyed through a low volt-age 2 wire connection and then decoded by the BMS unit. Once the signal is decoded the micro controller provides four inputs to the GSM modem which then in turn, sends SMS messages as configured.
FPC-30120SMS Alarm Sender
Up to 5 separate phone numbers to send messages toSending of a descriptive message whenever an alarm condition is initiated or clearedSending of alert message if backup battery voltage drops too low
Features
GSM modem (preconfigured with supplied phone numbers and SIM code)Antenna to suit1.7Ah or 3Ah SLA battery 12V Power supply / battery charger
Kit Includes
In order to pre-configure the GSM modem, the customer will need to supply an active SIM card, along with; up to 5 Phone numbers, all of which are messaged upon an alarm action. SIM code, so that the GSM modem can access the SIM card. Station name, to be included in any SMS sent, for identifying which pump station has sent the message.
Notes
OFF
ON
1
4
7
2
5
8
3
6
9
0* + #
ghi jkl
tuv
abc def
pqrs
mno
wxyz
MATelec
PUMP STATION
NO.1HI LEVEL
FAULT
Dual PumpController
PUMP 1 PUMP 2
AUTO
OFF
AUTO
OFF
MAN MAN
MUTE
RUNNING RUNNING
FAULT FAULT
HIGHLEVEL
POWERON
DANGER - HIGH VOLTAGE DO NOT REMOVE COVER. AUTHORIZED PERSONS ONLY
PRESS FOR 3 SECONDS TO CLEAR FAULT
Section 3
NOTE: Depending on which pump controller model has been ordered, the SMS Alarm Sender may need to be housed in a separate enclosure.
Australia
®
Configuration & Data Log DevicePump Control Auxiliary Equipment
Section 3
FPC-15010 - Overview
FPC-15 Series Pump Controller Configuration and Data Log Device is an extemely useful setup tool, which works in conjunction with the 15000 Series Single Pump Controller. The device interconnects directly with the PCB and is able to both, configure a variety of features, as well as report logged data. The device has an LCD screen, arrow and enter keys making it very user friendly.
Configurable Features:
• Manual mode timeout• High level - enable• High Level alarm - delay time• High level alarm - automatic reset• Low level alarm - enable• Max idle timer - enable• Max idle time• Anti-seize timer - enable• Anti-seize time• Anti-seize run time• Max run timer - enable• Max run time• Max run cool down time• High pressure current sensing - enable• High pressure current limit• Overload current sensing - enable• Overload current limit
Logged Data:
• Number of pump starts• Accumulated pump run hours• Number of power resets• Number of overloads• Number of high levels• Number of low levels• Number of pressure inhibits• Number of maximum run timeouts• Serial number• Software version
FPC-15 SERIESPUMP CONTROLLERCONFIGURATION &DATA LOG DEVICE
Features