automation premium catalog 2008 sche

466
Catalogue 2008 Automation platform Modicon Premium

Upload: fenixcross

Post on 01-Dec-2014

172 views

Category:

Documents


1 download

DESCRIPTION

Catálogo

TRANSCRIPT

Automation platform Modicon PremiumCatalogue

2008

A full range of catalogues for . . . . .

Safety Functions and Solutions using PreventaCatalogue

2008/2009

Detection

Automation

Automation

Operator dialog

Motion and Drives

Global Detection Electronic and electromechanical sensors n 960262 MKTED208052EN Photo-electric sensors Proximity sensors Capacitive proximity sensors Ultrasonic sensors Limit switches Pressure switches Rotary encoders Radio frequency identication Machine cabling accessories

Modicon Momentum distributed I/O and control n 807861 MKTED205061EN

Twido programmable controller and TwidoSuite software n 960211 DIA3ED2070902EN Controller base Discrete, analogue I/O Communication

Control and signalling components n 960239 MKTED208031EN Control and signalling units Control stations & enclosures Cam switches Beacons and indicator banks Pendant control stations Controllers Emergency stops Foot switches

Motion control Lexium 05 n 808610 DIA7ED2050910EN

Modicon Quantum automation platform, Unity, Concept & ProWORX 32 n 960237 MKTED208011EN

Motion control Lexium 15 n 816811 DIA2ED2060506EN

Modicon Premium and Unity - PL7 software n 960268 MKTED208054EN

Automation functions, relays, interfaces and power supplies n 960162 MKTED207031EN Smart relays Timing relays Measurement & control relays Analogue interfaces Counters Plug-in relays Interfaces for discrete signals Power supplies & transformers Software PLCs and safety controllers programming software

Human-Machine interfaces n 821230 MKTED206071EN Operator interface terminals Industrial PCs HMI and SCADA PC-based software Software Vijeo Designer Operator terminal software

Lexium Controller motion controllers n 960165 DIA7ED2070410EN Servo drives and Servo motors Motion controllers Motion control modules Modicon Premium and Modicon Quantum

Modicon M340 and Unity software n 960128 DIAED2061001EN PLCs Discrete, analogue I/O and application-specic solutions Communication

Soft starters and variable speed drives n 960142 MKTED206111EN Soft starters and variable speed drives Software Software for drives and motors Motor control programming software

Not all products shown in this catalogue are available in every country. Check individual countrys web site or Sales Ofce for product availability. See on: www.schneider-electric.com

. . . . all Automation & Control functions

Motor control

Machine safetyThis catalogue contains Automation and Control function products relating to machines Safety

Interfaces and I/O

Power supplies

Systems & architecturesThis catalogue contains Automation and Control function products relating to Communication

&Motor starter solutions Control and protection components n 814711 MKTED205103EN Contactors Circuit-breakers, fuse carriers Thermal relays Combinations, motor controllers Mounting solutions Motor starter mounting kits

&Interfaces, I/O splitter boxes and power supplies n 70263 MKTED203113EN Discrete interfaces Pre-wired interfaces IP 67 Splitter boxes

&Power supplies and transformers Phaseo n 822591 DIA3ED2061209EN Switch mode power supplies Filtered rectified power supplies Transformers

&Safety functions and solutions using Preventa n 960260 MKTED208051EN Safety PLCs Safety controllers Safety monitors Safety solutions on AS-Interface cabling system Safety switches Safety light curtains Safety mats Emergency stops Control stations Enabling switches Foot switches Beacons & indicator banks Switch disconnectors Thermal-magnetic motor circuit breakers Enclosed D.O.L. starters Software XPSMFWIN configuration software XPSMCWIN configuration software

&Machine & Installations with industrial communication n 960153 MKTED207012EN Preferred implementations Ethernet TCP/IP, the universal communication standard CANopen for machines and installations AS-interface, simple and safe Products Human-Machine interface Controllers and PLCs Field devices Infrastructure and wiring Gateways Software and tools Collaborative Automation Partner Program & Partners

&Terminal blocks n 960151 MKTED207011EN Terminal blocks Cable ends

&IP 20 distributed inputs/outputs Advantys STB n 960266 MKTED208053EN Modules for automation island Network interfaces Power distribution Digital I/O, analogs and application-specific Software STB configuration software

General Contents

Modicon Premium automation platform

1 Premium processors

1 2 3 4 5 6 7 8 9 10

Unity selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/2 Unity processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/4 Unity slot-PLCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/14 PL7 selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/24 PL7 processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/26

2 Racks, I/O architectures and power suppliesPower supply and fan modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/2 Single rack configuration.................................... page 2/6 Multi-racks configuration without remote module................ page 2/8 Multi-racks configuration with remote module.................. page 2/12

3 Discrete and analog I/ODiscrete I/O modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p age 3/2 Analog I/O modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/20 Distributed I/O modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/28 TeSys Quickfit for motor starter components . . . . . . . . . . . . . . . . . . . page 3/42

4 Application-specific modules and solutionsPreventa safety modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4/2 Counter and electronic cam modules . . . . . . . . . . . . . . . . . . . . . . . . . . page 4/18 Motion control modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4/32 MFB, Motion Function Blocks..............................see page 9/20 Integrated weighing system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4/56 Hot Standby redundancy (Unity).............................. page 4/62 Warm Standby redundancy (PL7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4/72

5 CommunicationSelection guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/2 Ethernet network - Transparent Ready . . . . . . . . . . . . . . . . . . . . . . . . . page 5/12 CANopen machine bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/62 AS-Interface sensor/actuators bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/68 X-Way bus and network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/74 Modbus Plus network and Profibus DP/InterBus buses . ........... page 5/90 Modbus, Uni-Telway and asynchronous serial links . . . . . . . . . . . . . page 5/100

2

General Contents

6 SoftwareUnity software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/2 PL7 software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/60 Vijeo Citect supervisory software............................. page 6/90 OPC data server software.................................. page 6/100

1 2 3 4 5 6 7 8 9 10

7 Human/Machine InterfacesMagelis Small Panel units and terminals . . . . . . . . . . . . . . . . . . . . . . . . page 7/2 Magelis Advanced Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/4 HMI software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/6

8 Connection interfaces and power suppliesAdvantys Telefast ABE 7 pre-wired system . . . . . . . . . . . . . . . . . . . . . . page 8/2 Phaseo Universal range power supplies . . . . . . . . . . . . . . . . . . . . . . . page 8/20

9 ServicesTreatement for severe environments, Conformal Coating Premium modules . . . . . . . . . . . . . . . . . . . . . . . . . page 9/2 TSX PSY power supply module selection document.............. page 9/6 Technical information Standards, certifications and environment conditions . . . . . . . . . . . . . page 9/8 Ethernet network, infrastructure............................. page 9/12 Automation product certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9/18 Index Product reference index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9/22

3

1 2 3 4 5 6 7 8 9 10

1/0

Contents

1 - Modicon Premium processors

Premium processors - UnityProcessors and slot-PLCsSelection guide page 1/2 b Premium processors v v v v v Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/5 Memory structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/8 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/10 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/12

1 2 3 4

b Atrium slot-PLCs v v v v v v Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TCP/X-Way software gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/14 page 1/16 page 1/17 page 1/18 page 1/20 page 1/21

b PCMCIA memory extension cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/22

Premium processors - PL7Processors Selection guide page 1/24 b Premium processors v v v v v Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/26 page 1/27 page 1/28 page 1/30 page 1/31

5 6 7 8 9 10

b PCMCIA memory extension cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/32

1/1

Selection guide

Modicon Premium automation platformUnity

Premium processors and Atrium slot PLCs

Premium/Atrium platforms for Unity Pro software offer

TSX 57 0p processor

TSX 57 1p processors

1 2Number of racks (according to rack type) 1 with 4, 6, 8 or 12 slots 256 channels (8-, 16-, 32- or 64-channel module) 12 channels (4-, 8- or 16-channel module) 4 with 4, 6, or 8 slots or 2 with 12 slots 512 channels (8-, 16-, 32- or 64-channel module) 24 channels (4-, 8- or 16-channel module)

g

3 4

In-rack I/O (1)

Discrete I/O Analog I/O

In-rack applicationspecific channels

Max. no. of channels Integrated counter (max. 40 kHz) Counter Motion (2) Weighing Serial links Modbus Uni-Telway Character mode

4 8 Modules with 2/4 counter channels 1 MHz max., single-channel electronic cam module Modules with 1/2 axes for stepper motors, 2/3/4 axes for analog control servo motors, 8/16 axes with SERCOS digital link Module for 8 load cells (2 application-specific channels) TSX SCY in-rack communication modules (1 application-specific channel) RS 232, RS 485 or current loop (3) (4) master/slave PCMCIA modules and RS 485 master/ slave in-rack communication modules 1 integrated RS 485 master/slave channel, RS 232, RS 485 or current loop (3) (4) master/slave PCMCIA modules and RS 485 master/slave in-rack communication modules 1 integrated RS 485 channel, RS 232, RS 485 or current loop PCMCIA modules (3) (4) and RS 485 in-rack communication modules 1 in-rack module 2 in-rack modules 1 integrated PCMCIA module 1 PCMCIA module (3)

Serial link connections

5Bus connections

6 7 8

AS-Interface actuator/sensor bus master V2 CANopen machine bus master V4.02 InterBus fieldbus master V2 (5) or Profibus DP fieldbus master V0 Class 1 and 2 (5) Max. no. of networks Ethernet Fipway/Ethway/Modbus Plus modules

Network connections

1 Multiprotocol in-rack modules (Modbus /TCP, Uni-TE, Global Data, I/O Scanning, TCP Open), Web server, FactoryCast server or FactoryCast HMI server Fipway module (4), Ethway in-rack modules Modbus Plus (3), Fipway (3)(4) modules, Ethway in-rack modules Process control EFB library 96 Kb program and data 96 Kb program and data

Integrated process control Hot Standby availability Memory capacity

Configurable loops Programmable loops

Without PCMCIA extension With PCMCIA extension Data storage

USB programming port Power supply

128 Kb program 224 Kb program 96 Kb data 96 Kb data 256 Kb (PCMCIA extension in upper slot (0) on processor) 100240 V a, 24 c non-isolated and 2448 V c isolated power supply. A power supply is required for each rack.

9 10

Premium processor

Standard Integrated Ethernet (9) Integrated CANopen Integrated Fipio

TSX P57 104M TSX P57 1634 TSX P57 0244M

g

TSX P57 154M (11)

Atrium slot PLC

Standard Integrated Fipio

Pages 1/12 (1) The maximum values for the numbers of discrete and analog I/O are cumulative (with the exception of TSX H57 24M/44M Hot Standby processors) . (2)1axis=1application-specificchannel,exceptforSERCOSmoduleswhere,dependingontheconfiguration,themodule=232channels. (3) Module to be inserted into the lower PCMCIA slot (no . 1) on a Premium processor or into the external PCMCIA slot (no . 1) on an Atrium slot PLC . (4) Module to be inserted into the TSX SCY 21 601 in-rack communication module slot . (5) The InterBusandProfibusDPlimitsarenotcumulative. (11) The TSX P57 154M processor does not support the CANopen bus PCMCIA module .

1/2

TSX 57 2p processors and slot PLCs TSX 57 3p processors and slot PLCs

TSX 57 4p processors

TSX 57 5p processors

TSX 57 6p processors

1 2 3 4 5 6 7 8 9 10

n1 with 6, 8 or 12 slots 512 channels (64channel modules) 80 channels (16channel modules) 18 16 with 4, 6, or 8 slots or 8 with 12 slots 1024 channels (8-, 16-, 32- or 64-channel modules) 80 channels (4-, 8- or 128 channels (4-, 8- or 16-channel 16-channel modules) modules) 24 32

n1 with 6, 8 or 12 slots 512 channels (64channel modules) 128 channels (16channel modules) 18 16 with 4, 6, or 8 slots or 8 with 12 slots 2048 channels (8-, 16-, 32- or 64-channel modules) 256 channels (4-, 8- or 512 channels (4-, 8- or 16-channel 16-channel modules) modules) 64

n

Modules with 2/4 counter channels, single-channel Modules with 2/4 counter channels, single-channel electronic electronic cam cam Modules with 1/2 axes for stepper motors, 2/3/4 axes for Modules with 1/2 axes for stepper motors, 2/3/4 axes for servo motors, 8/16 axes with SERCOS digital link servo motors, 8/16 axes with SERCOS digital link Module for 8 load cells (2 application-specific channels) Module for 8 load cells (2 application-specific channels) TSX SCY in-rack communication modules (1 application-specific channel) RS 232, RS 485 or current loop (3) (4) master/slave PCMCIA modules and RS 485 master/slave in-rack communication modules 1 integrated RS 485 master/slave channel, RS 232, RS 485 or current loop (3) (4) master/slave PCMCIA modules and RS 485 master/slave in-rack communication modules 1 integrated RS 485 channel, RS 232, RS 485 or current loop PCMCIA modules (3) (4) and RS 485 in-rack communication modules 4 in-rack modules 8 in-rack modules 8 in-rack modules 1 PCMCIA module (3) 4 in-rack modules 5 in-rack modules

1 PCMCIA module (3) 1 in-rack module 3 in-rack modules

2

1 + for Atrium, 3 3 + 1 software 4 1 software gateway gateway Multiprotocol in-rack modules (Modbus/TCP, Uni-TE, Global Data, I/O Scanning (6), TCP Open), Web server, FactoryCast server or FactoryCast HMI server and via software gateway with Atrium slot PLCs Modbus Plus (3), Fipway (3)(4) module, Modbus Plus (3), Fipway (3) (4) (7) module, Ethway in-rack modules Ethway in-rack modules 10 channels with 3 loops max. Process control EFB library Yes 160/192 Kb program and data (8) 15 channels with 3 loops max. 20 channels with 3 loops max. Yes 192/208 Kb program and data (8) 1 Mb program and data 7 Mb program 1 Mb data 2 Mb program and data 7 Mb program 2 Mb data 30 channels with 3 loops max.

440 Kb program and data

768 Kb program 1.75 Mb program 2 Mb program 160/192 Kb data (8) 192/208 Kb data (8) 440 Kb data 8 Mb (PCMCIA extension in upper or lower slot (0 or 1) on processor) 1 100240 V a, 24 V c non-isolated and 2448 V c isolated power supply. A power supply is required for each rack.

TSX H57 24M(10)

TSX P57 204M TSX P57 2634M TSX P57 254MTSX PCI 57 204M

TSX P57 304M TSX P57 3634M TSX P57 354MTSX PCI 57 354M

TSX H57 44M(10)

TSX P57 4634M TSX P57 454M

TSX P57 5634M TSX P57 6634M TSX P57 554M

4/69 1/12 1/12 1/21 1/13 4/69 1/13 (6) TSX H57 24M/44M HotStandbyprocessorsdonotsupporttheEthernetI/OScanningservice. (7) TSX P57 4634M/5634M/6634MprocessorswithintegratedEthernetportdonotsupportthePCMCIAFipwaycard. (8) The second value applies to TSX P57 254M/354M processorswithintegratedFipiolinkandtotheTSX H57 24M Hot Standby processor . (9)TheintegratedEthernetportrequiresoneoftheavailablenetworkconnections. (10)TheintegratedEthernetportisdedicatedtoHotStandbycommunication(CPUSynclinkbetweenPrimaryandRedundantprocessors).

n New feature1/3

Presentation

Modicon Premium automation platformUnity processors

1 2 3 4 5 6 7 8 9 10Description: pages 1/5 Memory structure: pages 1/8

Modicon Premium TSX P57 pp4M, TSX P57 pp34M and TSX Hp4M automation platform processors manage the entire PLC station comprising: b Discrete I/O modules b Preventa safety modules b Analog I/O modules b Application-specific modules (counter, motion, weighing, communication)

Presentation

n The Premium processor offer has seen the addition of three new references: b TSX P57 6634M, high-end processor with 1 integrated Ethernet Modbus/TCP port and an internal 2 Mb RAM b TSX H57 24M/44M, which support the Hot Standby system (with "Primary" and "Secondary" PLCs), see pages 4/60 to 4/69The processors differ in terms of their memory capacities, processing speeds, the number of I/O and the number of communication ports. Depending on the model, they include: b 1 to 16 racks interconnected by means of Bus X (max. distance: 700 m) b 192 to 2040 discrete I/O b 12 to 512 analog I/O b 4 to 64 application-specific channels. Each application-specific module (counter motion control, communication or weighing) accounts for one or more applicationspecific channels. b 1 to 4 networks (Ethernet Modbus/TCP, Fipway, Modbus Plus, Ethway), 1 to 8 AS-Interface buses b 0 or 1 Fipio bus, 0 or 1 CANopen or Modbus Plus bus and 0 to 5 InterBus or Profibus DP (1) fieldbuses b 0 to 30 process control channels, with each channel capable of supporting up to 3 loops Depending on the model, Premium processors also feature: b A 10BASE-T/100BASE-TX Ethernet Modbus/TCP port (RJ45 connector) b A 1 Mbit/s Fipio bus link (bus manager) b Communication via 2 terminal ports (TER and AUX) using Uni-Telway or character mode protocol (typically a 19 or 115 Kbit/s programming terminal and an operator dialogue terminal) b A USB type TER port (for connecting a programming terminal) Each processor has two slots for a PCMCIA card: b An upper slot (no. 0) for battery-backed memory extension cards (program, symbols, constants and/or data files) b A lower slot (no. 1) for (1) a network card (Fipway, Modbus Plus) or bus (CANopen, Fipio Agent, Modbus, Uni-Telway and serial links). Memory extension cards intended specifically for storing data can also be inserted into this slot.Treatment for harsh environments

n If the Modicon Premium automation platform is destined for use in extremely

harsh environments, the "conformal coating" offer is available. This involves applying a coat of "humiseal 1A33" varnish to the electronic cards of the processor and power supply modules, I/O modules on Bus X and the racks. See page 9/2. Premium application design and installation

The installation of these Premium processors requires: b Unity Pro Medium, Large or Extra Large programming software. This is the same as the software for installing the Modicon M340 and Modicon Quantum platforms. b Optionally, depending on requirements: v The Unity Application Generator (UAG) specialist software for modelling and generating process applications v Unity EFB toolkit software for developing EF and EFB libraries in C language v Unity SFC View software for visualizing and diagnosing applications written in Sequential Function Chart (SFC) or Grafcet language

___________________________________________________________________________ (1) TSX H57 24M/44M Hot Standby processors do not support the following buses or networks: Fipio,CANopen,ModbusPlus,InterBusandProfibusDP.

n New featureCharacteristics: pages 1/10 References: pages 1/12 PCMCIA references: pages 1/22

1/4

Description

Modicon Premium automation platformUnity processorsDescription

8 1 2 3 4 5 6 7TSX P57 104M TSX P57 154M

TSX P57pp4M processors without integrated Ethernet portTSX P57 1p4M single-format processors and TSX P57 2p4/3p4M double-format processors feature the following on the front panel: 1 A display block with 5 LEDs: v RUN LED (green): Processor in operation (program running) v ERR LED (red): Fault on the processor or its on-board devices (PCMCIA memory card and PCMCIA communication card) v I/O LED (red): Faults occurring on another station module or configuration fault v TER LED (yellow): Activity on TER or AUX terminal port v FIP LED (red): Activity on integrated Fipio bus (depending on model) 2 RESET button causing a cold restart of the PLC when it is activated 3 An 8-way female mini-DIN connector marked TER for connecting a programming or adjustment terminal (RS 485) 4 An 8-way female mini-DIN connector marked AUX for connecting a programming, adjustment or operator dialogue terminal (RS 485) 5 A PCMCIA slot (no. 0) for a memory card 6 A PCMCIA slot (no. 1) for a communication card or memory extension card for storing additional data 7 A 9-way SUB-D connector (on TSX P57 154/254/354M models) for Fipio bus communication (Fipio manager port) 8 An air recirculating heatsink (on TSX P57 0244/1p4M models)

1 2 3 4

1 2 3 4 5 6 7TSX P57 204M/304M TSX P57 254M/354M/454M

Processor with integrated CANopen port7 1 2 3 4 5 6

TSX P57 0244M

The TSX P57 0244M processor feature all or some of the following: 1 A display block with 4 LEDs: v RUN LED (green): Processor in operation (program running) v ERR LED (red): Fault on the processor or its on-board devices (PCMCIA memory card and PCMCIA communication card) v I/O LED (red): Faults occurring on another station module or configuration fault v TER LED (yellow): Activity on TER or AUX terminal port 2 RESET button causing a cold restart of the PLC when it is activated 3 An 8-way female mini-DIN connector marked TER for connecting a programming or adjustment terminal (RS 485) 4 An 8-way female mini-DIN connector marked AUX for connecting a programming, adjustment or operator dialogue terminal (RS 485) 5 A PCMCIA slot (no. 0) for a memory card 6 A PCMCIA slot (no. 1) equipped with PCMCIA CANopen master V4.02 card, complete with cordset and tap junction (see page 5/65) 7 An air recirculating heatsink.

5 6 7 8 9 10

Presentation: page 1/4

Memory structure: pages 1/8

Characteristics: pages 1/10

References: pages 1/12

PCMCIA references: pages 1/22

1/5

Description(continued)

Modicon Premium automation platformUnity processorsDescription

1 3

2

TSX P57 pp34M processors with integrated Ethernet portTSX P57 1634M/2634M/2834M double-format processors with integrated Ethernet Modbus/TCP port feature, on the front panel: 1 A display block with 5 LEDs: v RUN LED (green): Processor in operation (program running) v ERR LED (red): Fault on the processor or its on-board devices (PCMCIA memory card and PCMCIA communication card) v I/O LED (red): Faults occurring on another station module or configuration fault v TER LED (yellow): Activity on TER or AUX terminal port 2 A display block relating to the integrated Ethernet port featuring 5 LEDs: v RUN LED (green): Ethernet port ready v ERR LED (red): Ethernet port fault v COL LED (red): Collision detection v STS LED (yellow): Ethernet link diagnostics v Two TX and RX LEDs (yellow): Transmission/reception activity 3 RESET button causing a cold restart of the PLC when it is activated 4 An 8-way female mini-DIN connector marked TER for connecting a programming or adjustment terminal (RS 485) 5 An 8-way female mini-DIN connector marked AUX for connecting a programming, adjustment or operator dialogue terminal (RS 485) 6 An RJ45 connector for connection to the Ethernet Modbus/TCP 10BASE-T/100BASE-TX network 7 A PCMCIA slot (no. 0) for a memory card 8 A PCMCIA slot (no. 1) for a communication card or memory extension card for storing additional data

14 5 6 7 8

2 3 4 5 6 7 8 9 10Presentation: page 1/4

TSX P57 1634M/2634M/3634M

Memory structure: pages 1/8

Characteristics: pages 1/10

References: pages 1/12

PCMCIA references: pages 1/22

1/6

Description(continued)

Modicon Premium automation platformUnity processorsDescription

1 2

1 2

TSX P57 4p4/5p4/6634M and TSX H57 p4M high-performance processors (1)Premium (numbers) double-format high-performance processors TSX P57 454/554M/4634M/5634M/6634M and TSX H57 24M/44M (1) feature the following on the front panel: 1 A display block with 5 LEDs: v RUN LED (green): Processor in operation (program running) v ERR LED (red): Fault on the processor or its on-board devices (PCMCIA memory card and PCMCIA communication card) v I/O LED (red): Faults occurring on another station module or configuration fault v TER LED (yellow): Activity on the AUX terminal port v FIP LED (red): Activity on integrated Fipio bus (TSX P57 454/554M model)

1 2 3 4 5 6 7 8 9 10

3 4 5 6 7 8TSX P57 454M/554M

9TSX P57 4634M/5634M TSX P57 6634M

In the case of models with an integrated Ethernet port (TSX P57 4634M/5634M/6634M), this display block features 6 additional LEDs: v RUN LED (green): Ethernet port ready v ERR LED (red): Ethernet port fault v COL LED (red): Collision detection v STS LED (yellow): Ethernet link diagnostics Two TX and RX LEDs (yellow): Transmission/reception activity 2 A "Memory extract" button for extracting the PCMCIA memory extension card. The associated "Memory extract ready" LED indicates that this card can be extracted safely. 3 RESET button causing a cold restart of the PLC when it is activated 4 An 8-way female mini-DIN connector marked AUX for connecting a programming, adjustment or operator dialogue terminal 5 A USB type connector marked TER for connecting a programming terminal (requires the PC-compatible 3 m connection cable, reference UNY XCA USB 033, to be ordered separately) 6 A PCMCIA slot (no. 0) for a memory extension card 7 A PCMCIA slot (no. 1) for a communication card or memory extension card for storing additional data 8 A 9-way SUB-D connector (on TSX P57 454M/554M models) for Fipio bus communication (Fipio manager port) 9 An RJ45 connector (on TSX P57 4634M/5634M/6634M models) for connection to the Ethernet Modbus/TCP 10BASE-T/100BASE-TX network USB port The USB port 5 boasts a faster useful data rate (12 Mbit/s) than the Uni-Telway terminal port available on Premium processors. The USB port is compatible with Unity Pro programming software and the OPC Factory Server (OFS). TSX P57 4p4M/5p4M/6634M processors can be connected to a USB bus comprising several peripheral devices. However: b Only one processor must be connected to the USB bus b No device on the USB bus (modem, printer) can be controlled by the PLC.

(1) TSX H57 24M/44MHotStandbyprocessor,seedescriptiononpage4/61 .

__________________________________________________________________

Presentation: page 1/4

Memory structure: pages 1/8

Characteristics: pages 1/10

References: pages 1/12

PCMCIA references: pages 1/22

1/7

Memory structure

Modicon Premium automation platformUnity processors

Memory structure

1 2 3 4 5 6

Processor without PCMCIA memory card Located data96 to 2048 Kb

The application memory is divided into memory areas, which are physically distributed across the internal RAM and 0, 1 or 2 PCMCIA memory extension cards:1 1

Global and DFB unlocated data

Internal RAM

Program, symbols and 2 area for online program modification

Constants

3

1 The application data, which is always found in the internal RAM, is divided into two possible types: v Located data, corresponding to data defined by an address (e.g. %MW237), which can have a symbol linked to it (e.g. Counter_rejects). v Unlocated data, corresponding to data defined only by a symbol. This type of addressing eliminates the problems of memory mapping management, because addresses are assigned automatically. It also facilitates data structuring. v DFB unlocated data, corresponding to DFB user function block data. The size of this area (which is determined by the physical size of the available internal RAM) depends on the processor model, see pages 1/12 and 1/13. 2 Area in internal RAM or PCMCIA memory card for the program and symbols. If this area happens to be inside the internal RAM, it also contains the area for modifying the program in online mode (1). This area contains the program's executable binary code and IEC source code. The user selects the type of information to be stored in the PLC memory. 3 Constants area in the internal RAM or the PCMCIA memory card (slot no. 0) 4 Area for storing additional data (slot no. 0 or no. 1), e.g. for production data and manufacturing recipes Memory organization

Processor with PCMCIA memory card in slot no . 0 Located data96 to 2048 Ko

1 1 1

Internal RAM

Global unlocated data DFB unlocated data DFB unlocated data Program and symbols

2

PCMCIA card (slot no. 0)

Constants Additional data storage

3 4

The memory will be organized in one of two ways, depending on whether the Premium processor is fitted with 0, 1 or 2 memory extension cards: b Application in internal RAM: In this case, the application is completely loaded into the processor's internal battery-backed RAM (2), the capacity of which depends on the processor model (96 Kb to 2 Mb). b Application in PCMCIA card: In this case, the internal RAM is reserved for the application data. The PCMCIA memory card (slot no. 1) contains the program space (program, symbols and constants areas) (128 Kb to 2 Mb). Certain types of PCMCIA memory card also host the data storage area (max. 6976 Kb). Symbols areas

128 to 7168 Ko

Processor with data storage type memory card in slot no . 0 Located data96 to 2048 Kb

1 1

Having the symbols area in the same place as the program area is optional. However, if the application symbols database is available on the PLC, it means that, when an empty programming terminal is connected to the PLC, all the elements needed to debug or upgrade this PLC can be transferred to the terminal.

7 8 9 10

Unlocated data

Internal RAM

Program, symbols and area for online program 2 modification Constants

3

4096 or 8192 Ko

PCMCIA data storage card (slot no. 0)

Additional data storage

4

(1)IfaPCMCIAcardhasbeeninserted,itisthememoryonthismemorycardthatwillbeused forthepurposeofmodifyingtheprograminonlinemode(outsideareas2,3and4opposite). (2)TheinternalRAMisbackedupbyanoptionalbattery(withaservicelifeof3years),whichis located in the power supply module (see page 2/4) .

__________________________________________________________________

1 1Presentation: page 1/4

2

Description: pages 1/5

Characteristics: pages 1/10

References: pages 1/12

PCMCIA references: pages 1/22

1/8

Memory structure (continued)

Modicon Premium automation platformUnity processors

Processor with mixed type memory card in slot no . 0 and data storage type memory card in slot no . 1 (1)96 to 2048 Ko

Memory structure (continued)1 1

Extension of the data storage area Memory cards reserved for data storage (4096 or 8192 Kb) are used to: b Access the data storage area in cases where the application is fully loaded into the internal RAM. In this case, the data storage memory card is inserted into PCMCIA slot no. 0. b Free up memory to serve as additional program space when the application is on the PCMCIA card (slot no. 0). In this case, the data storage memory card is inserted into PCMCIA slot no. 1 (although the memory card in slot no. 0 can still be used for some of the data). Unity Pro programming software helps the application designer to manage the structure and organize how the memory space on the Premium PLC is occupied. Protecting the application Regardless of the PLC memory structure (whether the application is located in the internal RAM or on the PCMCIA card), it is possible to prevent the application from being accessed (for the purpose of reading or modifying the program) by only loading the executable code into the PLC.4

Located data Global and DFB unlocated data

Internal RAM

1 2 3 4 5 6 7 8 9 10

Program and symbols PCMCIA card (slot no. 0)128 to 7168 Ko

2

Constants

3

Additional data storage (zone A)

4

PCMCIA data storage card (slot no. 1)

4096 or 8192 Ko

Additional data storage (zone B)

A memory protection bit, set in configuration mode, is also available to prevent any program modification (via the programming terminal or downloads). Program modification in online mode

(1) TSX P57 20 processors and higher

This function is different from previous versions of Premium PLCs (with PL7 software) in that it now allows program code and data from different parts of the application to be added or modified in a single modification session (thus making modification unified and consistent with regard to the controlled process). This increased flexibility comes at a cost in terms of the amount of program memory required. In order for the program to be modified in online mode, the amount of program memory space available must be at least equal to the combined size of all sections of the Unity Pro program affected by the single modification session concerned. Depending on circumstances: b In the case of a processor with a memory extension card, there will be sufficient memory left on the card for online modification, provided that the recommendations on page 1/22 are observed. b In the case of a processor without a memory extension card, if the user wants to be able to make modifications in online mode, he or she must select a processor on the basis of the following: v The anticipated size of the application v The number and size of the program sections to be modified in online modeNote:AmemoryextensioncardbasedexclusivelyonFlashEPROMtechnology(without additionalSRAM)isclearlyincapableofsupportingonlineprogrammodifications.

Presentation: page 1/4

Description: pages 1/5

Characteristics: pages 1/10

References: pages 1/12

PCMCIA references: pages 1/22

1/9

Characteristics

Modicon Premium automation platformUnity processors

1 2 3 4 5 6 7 8 9 10

Premium PLCs have been developed to comply with major national and international standards on electronic industrial automation equipment. See pages 9/8 to 9/19 "Standards, certification and environmental conditions".

Characteristics and performance4/6/8 slots 12 slots Max. no. of slots for modules Max. no in-rack Discrete I/O (3) Analog I/O Process control channels No. of racks

Types of processor Maximum configuration Functions

TSX P57 0244M 1 1 12

TSX P57 104M 4 2 32

TSX P57 1634M

TSX P57 154M

TSX P57 204M 16 8 128

TSX P57 2634M (1)

TSX P57 254M

192/256 (2) 512 12 24

Application-specific channels, number Application-specific channels, type Ethernet Fipio manager Serial link Network (Ethernet, Fipway, Ethway, Modbus Plus) AS-Interface bus CANopen or Modbus Plus bus

1024 80 10 (up to 30 parameterizable simple loops) Programmable loops via EFB control blocks (with Unity Pro Large and Extra Large) 4 8 24

Counter, axis control, weighing and serial links (Modbus, Uni-Telway and asynchronous) 1 (63 agents) 1 link with 2 connectors (TER and AUX) 19.2 Kbit/s 1 1 integrated 1 Ethernet port 1 2 1 integrated 1 CANopen 96 prog. + data 224 prog. 128 prog. 96 data 96 data 256 4096 64 for internal words %Mpi 64 for constant words %Kpi Elementary EDT and derived DDT data: 32 Kb 1 Modbus Plus only 1 1 1 (127 agents)

Integrated connections

Max. no. of connections

1 integrated 1 Ethernet port 4 1 1 160 prog. + data 768 prog. 160 data 192 prog.+ data 768 prog. 192 data

Memories

Maximum capacity

InterBus or Profibus DP bus Without PCMCIA card KbWith PCMCIA card Data storage Kb Kb bits Kb Kb

Maximum size Located internal bits of object zones (%Mi) Located internal data Unlocated internal data Application structure Tasks Master Fast Auxiliary Event-triggered Boolean On word or fixed-point arithmetic On floating points Boolean On word or fixed-point arithmetic On floating points 100% Boolean

16,384 (limited to 8192 with current PCMCIA cards) 8132

Execution time Without for one PCMCIA card instruction

ms ms ms ms ms ms

Elementary EDT and derived DDT data: 64 Kb DFB and EFB function blocks: Size per instance: 64 Kb, unlimited number of instances (7) 1 1 1 1 1 1 32 (1 of which has priority) 64 (1 of which has priority) 0.19 0.19 0.19 0.25 0.25 0.25 1.752.60 (7) 0.25 0.50 1.752.60 (7) 4.76 1.752.60 (7) 0.25 0.50 1.752.60 (7) 1.752.60 (7) 0.21 0.42 1.752.60 (7)

With PCMCIA card

No . of Kinstructions executed every ms

Kinst/ 4.76 4.76 ms 65% Boolean and Kinst/ 3.71 3.71 3.71 35% fixed arithmetic ms With PCMCIA 100% Boolean Kinst/ 3.10 3.10 3.70 card ms 65% Boolean and Kinst/ 2.10 2.10 2.53 35% fixed arithmetic ms System Tasks Master ms 1.00 1.00 1.00 overhead Fast ms 0.30 0.30 0.30 (1)FordetailsofTSX H57 p4Mprocessorcharacteristicsandperformance,seepage4/68 . (2)ThefirstvalueappliestotheTSX P57 Cp 0204MconfigurationandthesecondtotheTSX P57 0244M processor . (3)Onlyaffectsin-rackmodules.ThemaximumvaluesforthenumberofdiscreteI/O,analogI/O,application-specificchannelsandprocesscontrolchannelsare cumulative.TheremoteI/Oonthebusornetwork(Ethernet,CANopen,AS-Interface,Uni-Telway,Fipio,ModbusPlus,etc.)orthird-partybus(InterBus or ProfibusDP)arenotincludedinthesemaximumnumbers. Without PCMCIA card

1/10

Characteristics (continued)

Modicon Premium automation platformUnity processors

Premium PLCs have been developed to comply with major national and international standards on electronic industrial automation equipment. See pages 9/8 to 9/19 "Standards, certification and environmental conditions".

Characteristics and performance (continued)Types of processor TSX P57 304M TSX P57 3634M TSX P57 354M TSX P57 454M TSX P57 4634M (1) TSX P57 554M TSX P57 5634M 6634M

1 2 3 4 5 6 7 8 9 10

Maximum No. of racks configuration Functions

4/6/8 slots 12 slots Max. no. of slots for modules Max. no in-rack Discrete I/O (3) Analog I/O Process control channels Application-specific channels, number Application-specific channels, type Ethernet Fipio manager Serial link

16 16 16 8 8 8 128 128 128 1024 2040 2040 128 256 512 15 (up to 45 parameterizable simple 20 (up to 60 parameterizable 30 (up to 90 parameterizable loops) simple loops) simple loops) Programmable loops via EFB control blocks (with Unity Pro Large and Extra Large) 32 64 64 Counter, axis control, weighing and serial links (Modbus, Uni-Telway and asynchronous) 1 1 (127 agents) 1 1 1 (127 agents)

Integrated connections

Max. no. of connections

Memories

Maximum capacity

Network (Ethernet, Fipway, Ethway, Modbus Plus) AS-Interface bus CANopen or Modbus Plus bus InterBus or Profibus DP bus Without PCMCIA card Kb With PCMCIA card Kb Kb bits Kb Kb

1 link with 2 connectors (TER and AUX) 19.2 or 115 Kbit/s 3 3 including 1 3 integrated Ethernet port 8 1 3 192 prog. + data

1 x 12 Mbit/s USB link (TER), 1 x 19.2 Kbit/s (AUX) link 4 4 including 1 4 integrated Ethernet port (4) 8 8

4 including 1 integrated Ethernet port (4)

4

5 1024/2048 (5) prog. + data 7168 prog. 1024/2048 data (5) 32,768

Data storage Maximum size Located internal bits of object zones (%Mi) Located internal data Unlocated internal data

208 prog. 440 + data prog. + data 1792 prog. 2048 prog. 1792 prog. 208 data 440 data 192 data 16,384 (limited to 8192 with current PCMCIA cards) 16,384 32,768 64 for internal words %Mpi 64 for constant words %Kpi Elementary EDT and derived DDT data: 64 Kb DFB and EFB function blocks: - Size per instance: 64 Kb - Unlimited number of instances (6) 1 1 64 (1 of which has priority) 0.12 0.17 1.75...3.00 (7) 0.17 0.32 1.75...3.00 (7) 6.72 5.11 4.59 3.11 1.00 0.35

128 for int. words %Mpi 64 for const. words %Kpi Elementary EDT and derived DDT data: Unlimited (6) DFB and EFB function blocks: - Size per instance: unlimited (6), - Unlimited number of instances (6) 1 1 1 1 4 64 (1 of which has priority) 128 (1 of which has priority) 32 (timers) 0.0390.057 (7) 0.0375...0.045 (7) 0.0540.073 (7) 0.045...0.060 (7) 0.550.63 (7) 0.0480.057 (7) 0.0540.073 (7) 0.550.63 (7) 15.75 11.40 15.75 11.40 1.00 0.08 0.48...0.56 (7) 0.0375...0.045 (7) 0.045...0.060 (7) 0.48...0.56 (7) 20.26 14.00 20.26 14.00 1.00 0.07

Application structure

Tasks

Master Fast Auxiliary Event-triggered Boolean On word or fixed-point arithmetic On floating points Boolean On word or fixed-point arithmetic On floating points 100% Boolean 65% Boolean and 35% fixed arithmetic 100% Boolean 65% Boolean and 35% fixed arithmetic Master task Fast task ms ms ms ms ms ms Kinst/ ms Kinst/ ms Kinst/ ms Kinst/ ms ms ms

Execution time for one instruction

Without PCMCIA card

With PCMCIA card

Typical Without program PCMCIA card code execution time for 1 With PCMCIA Kinstruction card

System overhead

(4) TSX FPP 20 PCMCIAFipwaycardnotsupported. (5)ThefirstvalueappliestoTSX P57 554M/5634M processors and the second to the TSX P57 6634M processor . (6) Within the limits of the processor's data memory capacity (7) Values limited according to type of instruction .

1/11

References

Modicon Premium automation platformUnity processors

TSX 57 processors

1 2TSX P57 0244M

I/O capacity (2)

Capacity Memory

TSX 57 0p 1 rack256 discrete I/O 12 analog I/O 4 applicationspecific channels 96 Kb integrated 128 Kb on PCMCIA

Control channels 0

Maximum number of bus/network modules 1 network 1 AS-Interface bus

Integrated port

Reference (3)

Weight kg

CANopen

TSX P57 0244M

0.320

TSX 57 1p 4 racks (4)512 discrete I/O 24 analog I/O 8 applicationspecific channels 96 Kb 0 integrated 224 Kb max. on PCMCIA 1 network 2 AS-Interface buses 1 CANopen bus 2 AS-Interface buses Ethernet 1 CANopen bus 1 network 2 AS-Interface buses Fipio TSX P57 104M 0.380

TSX P57 1634M TSX P57 154M

0.420

3TSX 57 2p 16 racks (4)

4TSX P57 1634M

1024 discrete I/O 80 analog I/O 24 applicationspecific channels

160 Kb 10 integrated 768 Kb max. on PCMCIA

1 network 4 AS-Interface buses 1 CANopen bus (5) 1 fieldbus (5) 4 AS-Interface buses Ethernet 1 CANopen bus (5) 1 fieldbus (5)

TSX P57 204M

0.520

TSX P57 2634M

5TSX 57 3p 16 racks (4)

192 Kb 10 integrated 768 Kb max. on PCMCIA

TSX H57 24M 2 Ethernet networks Ethernet dedicated to Hot Standby 1 network Fipio 4 AS-Interface buses 1 CANopen bus (5) 1 fieldbus (5) TSX P57 254M

0.560

6TSX P57 2634M/3634M

1024 discrete I/O 128 analog I/O 32 applicationspecific channels

192 Kb integrated 1792 Kb max. on PCMCIA

15

7 8TSX P57 154M/254M/354M

208 Kb integrated 1792 Kb max. on PCMCIA

15

3 networks 8 AS-Interface buses 1 CANopen bus (5) 3 fieldbuses (5) 2 networks Ethernet 8 AS-Interface buses 1 CANopen bus (5) 3 fieldbuses (5) 3 networks Fipio 8 AS-Interface buses 1 CANopen bus (5) 3 fieldbuses (5)

TSX P57 304M

0.520

TSX P57 3634M

TSX P57 354M

0.560

(1) Two of these channels are used by the TSX CTY 2A2-channel40kHzcountermoduleintegratedintotheconfiguration. (2) Cumulative maximum values . The number of remote I/O on the various buses is not taken into account . (3)ProductsuppliedwithmultilingualQuickReferenceGuide:English,French,German,SpanishandItalian. (4) Maximum number of TSX RKY 4EX/6EX/8EX racks(4,6or8slots).UsingtheTSX RKY 12 EX rack (12 slots) is the same asusing2rackswith4,6or8slots. (5)Fieldbus:InterBusorProfibusDP.

9 10Presentation: page 1/4 Description: pages 1/5 Memory structure: pages 1/8 Characteristics: pages 1/10 PCMCIA references: pages 1/22

1/12

References(continued)

Modicon Premium automation platformUnity processors

TSX 57 processor (continued)I/O capacity (1) Capacity Memory Control channels 20 Maximum number of bus/network modules Integrated port Reference (2) Weight kg

1 2 3

TSX 57 4p 16 racks (3)2040 discrete I/O 256 analog I/O 64 application-specific channels 440 Kb integrated 2048 Kb max. on PCMCIA

3 networks Ethernet 8 AS-Interface buses 1 CANopen bus (4) 4 fieldbuses (4) 4 networks Ethernet

TSX P57 4634M

0.610

TSX H57 44M Ethernet dedicated to Hot Standby TSX P57 454M

0.610

TSX P57 454M/554M

4 networks Fipio 8 AS-Interface buses 1 CANopen bus 4 fieldbuses (4)

0.560

TSX 57 5p 16 racks (3)2040 discrete I/O 512 analog I/O 64 application-specific channels 1 Mb integrated 30 7168 Kb max. on PCMCIA Ethernet 3 networks 8 AS-Interface buses 1 CANopen bus 5 fieldbuses (4) Fipio 4 networks 8 AS-Interface buses 1 CANopen bus 5 fieldbuses (4) TSX P57 5634M 0.610

TSX P57 554M

0.560

4 5 6

TSX 57 6p 16 racks (3)TSX P57 4634M/5634M/6634M 2040 discrete I/O 512 analog I/O 64 application-specific channels 2 Mb integrated 30 7168 Kb max. on PCMCIA Ethernet 3 networks 8 AS-Interface buses 1 CANopen bus 5 fieldbuses (4) TSX P57 6634M 0.610

PCMCIA memory extension cardsPremium processors can support up to 2 memory extension cards. However, useful memory capacity is limited to the maximum size defined for the processor model. See pages1/22 and 1/23

Connection cables for PC programming terminalDescription Universal cable for terminal port/RS 232 port Use From terminal port Mini-DIN (TER or AUX) on: TSX Micro Premium TSX P57 0p/1p Premium TSX P57 2p/3p Atrium TSX PCI 57 20/35 Tap junction TSX P ACC 01 Mini-DIN (TER or AUX) on: TSX Micro Premium TSX P57 0p/1p Premium TSX P57 2p/3p Atrium TSX PCI 57 20/35 Tap junction TSX P ACC 01 To PC RS 232D port (9-way SUB-D) Length 2.5 m Reference TSX PCX 1031 Weight kg 0.170

70.4 m TSX CUSB 485 (5) TSX CRJMD 25 (5) 0.144

TSX PCX 1031 Cable for terminal port/ USB port USB port (USB/RS 485 converter) USB port (mini-DIN/RJ45 cable) USB port on a PC terminal

2.5 m

0.150

8 9 10

USB (TER) on: Premium TSX 57 4p/5p Quantum 140 CPU 6p1 TSXCUSB485

3.3 m

UNY XCA USB 033

(1) Cumulative maximum values . The number of remote I/O on the bus is not included . (2)ProductsuppliedwithamultilingualQuickReferenceGuide. (3) Maximum number of TSX RKY 4EX/6EX/8EXracks(4,6or8slots).UsingtheTSX RKY 12 EX rack (12 slots) is the same asusing2rackswith4,6or8slots. (4)Fieldbus:InterBusorProfibusDP. (5) The TSX CUSB485converterrequirestheuseofcableTSX CRJMD 25(length2.5m,equippedwith1mini-DINconnector and1RJ45connector).

Presentation: page 1/4

Description: pages 1/5

Memory structure: pages 1/8

Characteristics: pages 1/10

PCMCIA references: pages 1/22

1/13

Presentation

Modicon Premium automation platformAtrium slot PLCsUnity

Presentation

1 2 3 4 5 6 7 8 9 10Description: pages 1/16 Memory structure: pages 1/18

Atrium TSX PCI 57 204M/354M slot PLCs are PC format cards (PCI 32-bit/2533 MHz bus) to be integrated into a PC running under Windows 2000 or Windows XP. This combination of PLC and PC optimizes performance in applications requiring, for example, a higher level of communication, control or supervision functions. The slot PLC manages the entire PLC station, which comprises the same I/O modules as Premium processors (discrete, analog, application-specific and communication): b Locally, in one or more racks connected to bus X on the Atrium slot PLC b Using remote I/O via the same fieldbusesTSX PCI 57 pp4M

Two types of Atrium slot PLC are available. They can both accommodate: b A maximum of 16 extendable TSX RKY ppEX racks b A CANopen master bus function in their external PCMCIA slot Both have: b An internal PCMCIA slot (no. 0) to accommodate all types of memory extension card: program and symbols only, or mixed (program, symbols and data storage) b An external PCMCIA slot (no. 1) to accommodate the network card (Fipway, Modbus Plus) or bus (CANopen, Modbus, Uni-Telway, Fipio Agent and serial link) This slot can also accommodate the 4 or 8 Mb SRAM memory extension card used to store additional data (see page 1/22). Their distinguishing characteristics are: b The short application program execution time b The program memory and data memory capacity b 80 or 128 in-rack analog I/O b 24 or 32 application-specific channels: Each application-specific module (counter, motion control, serial link, or weighing) accounts for 1 or a number of applicationspecific channels. b 1 or 3 networks (Ethernet Modbus/TCP, Fipway, Modbus Plus, Ethway types), 1 Ethernet Modbus/TCP network, 4 or 8 AS-Interface buses V2.1, 1 CANopen bus and 1 or 3 third-party fieldbuses (InterBus, Profibus DP) b 10 or 15 process control channels Integrated communication Six means of integrated communication (communication that does not require the external rack to be connected on the slot PLC bus X) are possible: b CANopen master, via a PCMCIA card that is inserted into the external slot on the slot PLC b Fipio manager, via a 9-way SUB-D type connector on the faceplate of the TSX PCI 57 354M slot PLC b Ethernet Modbus/TCP, via the TCP/X-Way Windows-compatible gateway software, which communicates with the slot PLC via the PCI bus on the host PC (this software is either connected to an Ethernet port in the host PC, integrated into the motherboard or supplied on a PC format card) b InterBus master generation 4, via an additional PC format card, occupying an ISA bus slot and connected to the slot PLC via a ribbon cable that includes bus X b Modbus Plus or Fipway, via a PCMCIA card that is inserted into the external slot (no. 1) on the slot PLC b Communication via a terminal port (TER) using Uni-Telway or character mode protocol, 19.2 or 115 Kbit/s (typically a programming terminal or an HMI terminal)

Characteristics: pages 1/20

References: pages 1/21

PCMCIA references: pages 1/22

1/14

Presentation (continued)

Modicon Premium automation platformAtrium slot PLCsUnity

Presentation (continued)

TSX PSI 2010 standalone power supply In order to enable standalone operation in the event of a PC power outage, a standalone c 24 V TSX PSI 2010 power supply can be connected to a PCI or ISA bus slot to ensure continuity of service for the automation part of the system (only functions managed by the PC are disabled). Design and installation of Atrium applications Installation of these new Atrium slot PLCs requires: b Unity Pro Medium, Large, Extra Large or XL Safety programming software. This is the same as the software used on the Modicon M340 and Modicon Quantum platforms. b Optionally, depending on requirements: v Unity Application Generator (UAG) specialist software for modeling and generating process applications v Unity EFB toolkit software for developing EF and EFB function block libraries in C language v Unity SFC View software for displaying and diagnosing applications written in Sequential Function Chart (SFC) language The Atrium slot PLC is not supplied with any Windows driver or application type software programs. These are supplied with the Unity Pro, Vijeo Designer, Vijeo Citect, OFS (OPC Factory Server), etc. software. They enable connection to the slot PLC via: b Uni-Telway and the TER port on the front panel b PCIway and the PC hosts PCI bus b Ethernet Modbus/TCP (XIP)

1 2 3 4 5 6 7 8

Typical architectureBy integrating an Atrium slot PLC card, the architecture shown opposite can be created using any compatible PC (equipped with PCI bus slots) and PC Panel Magelis iPC This solution can provide a PLC architecture in which the I/O are: b Remotely located close to the machine or process via the fieldbus (1): v Ethernet Modbus/TCP via the TLX CD GTW 10M gateway software v CANopen with TSX CPP 110 PCMCIA card v Fipio with the integrated port on the TSX PCI 57 354M slot PLC v Modbus Plus with TSX MBP 100 PCMCIA card v InterBus with PC format slot PLC card, TSX IBX 100 ISA bus (link to TSX PCI 57 204M/354M slot PLC via ribbon cable) b And/or centralized in TSX RKY ppEX extendable racks. TSX RKY ppEX extendable racks connected on bus X permit the use of application-specific modules and the setting up of AS-Interface bus segments. For example: v TSX ETY 4103 or TSX ETY 5103 Ethernet Modbus/TCP module (with Web server, FactoryCast server or TSX WMY 100 module (FactoryCast HMI server) v InterBus TSX IBY 100 or Profibus DP TSX PBY 100 master module v TSX SAY 1000 AS-Interface V2.1 master module v TSX CAY, TSX CFY or TSX CSY 84 (SERCOS) motion control modules.

Ethernet Modbus/TCP

PC Panel Magelis iPC fitted with, for example: - Atrium TSX PCI slot PLC - Vijeo Designer and Unity Pro software - TCP/X-Way gateway software - c 24 V standalone power supply

Premium I/O extension racks

Altivar

Momentum Ethernet, CANopen, Fipio, Modbus Plus, InterBus

(1)CorrespondingtoanintegratedmodulesolutiononthehostPC,withouthavingtouse modules on extension racks on bus X .

_________________________________________________________________

9 10Description: pages 1/16 Memory structure: pages 1/18 Characteristics: pages 1/20 References: pages 1/21 PCMCIA references: pages 1/22

1/15

Description

Modicon Premium automation platformAtrium slot PLCsUnity

Description

1 2 3 4 57TSX PCI ACC1 TSX PCI 57 354M

Atriul slot PLCs 1 TSX PCI 57 204M/354M slot PLCs mechanically occupy two consecutive slots on the PCI bus, but only use one electrically (1). They feature: b On the faceplate: 1 A PCMCIA slot (no.1) for a communication card or memory extension card for storing additional data 2 A 9-way female SUB-D connector for connecting bus X to the first extendable rack supporting the I/O modules and application-specific modules 3 An 8-way female mini-DIN connector marked TER for connecting a programming terminal 4 A RESET button causing a cold restart of the slot PLC when it is activated 5 An ERR lamp (red); fault on the slot PLC or its on-board devices (PCMCIA memory or communication cards) 6 A 9-pin male SUB-D connector (on TSX PCI 57 354M model) for Fipio bus manager communication. b On the components side of the card: v 4 or 5 LEDs indicating the operating status (RUN, TER, BAT, I/O and FIP on the TSX PCI 57 354M) v A slot for a backup battery for the slot PLC internal RAM memory v A slot (no. 0) for a PCMCIA format memory extension card v A bus X line terminator circuit (type A) v A PCI bus connector for connection to the host PC Supplied with the slot PLC 1 bus X line terminator (type B) to be installed at the end of the last of the I/O and application-specific module support racks. Description of the additional TSX PCI ACC1 remote bus X faceplate 7 An additional faceplate, TSX PCI ACC1, fitted with a 9-way male SUB-D connector, enabling the slot PLC Atrium to be located in the middle of its extension racks rather than at one end of them. Description of the c 24 V TSX PSI 2010 power supply The c 24 V TSX PSI 2010 power supply is inserted into a PCI bus slot located next to the TSX PCI 57 204M/354M slot PLC. It occupies one slot mechanically but no slots electrically. It can provide the power supply for one slot PLC. It features the following on the front panel: 8 A 9-way female SUB-D connector enabling a second remote bus X to be connected (instead of using the TSX PCI ACC1 faceplate) 9 A 3-way female SUB-D connector for connection to the c 24 V power supply (male connector supplied) This power supply includes two ribbon cables for connection to the slot PLC, one for the power supply to the slot PLC and the other to ensure bus X continuity.

2 3 5 6 4

68

7TSX PSI 2010

9

8 9 10Presentation: pages 1/14 Memory structure: pages 1/18

__________________________________________________________________(1)AtriumslotPLCscanalsooperateusingjustonePCslot:Forthispurpose,carefullyunscrew and remove the external PCMCIA slot .

Characteristics: pages 1/20

References: pages 1/21

PCMCIA references: pages 1/22

1/16

Gateway, setup

Modicon Premium automation platformAtrium slot PLCsUnity

SCADA OFS server

TCP/X-Way gatewayThe TCP/X-Way software gateway performs 2 main functions for Atrium slot PLCs: b Communication using the Modbus or Uni-TE protocol via the Ethernet Modbus/TCP card integrated in the PC b Data exchange in both directions with remote stations via the telephone modem in the PCModbus

1 2 3 4 5 6 7 8 9 10

Ethernet Modbus/TCP

Uni-TE

1 2 3Premium PC

This software interfaces with the Atrium slot PLC PCIway driver and automatically routes messages. The most common configurations are: v Via Ethernet network (diagram opposite). Access is made secure by checking incoming IP addresses, in a similar way to the Premium PLC Ethernet TSX ETY 4103 module. The Global Data and I/O Scanning services are not supported. v Via modem link. Incoming calls are checked via the standard Windows password checking mechanisms. In addition to remote access with Unity Pro software, the TCP/IP gateway enables communication with other stations that can be connected to a local Ethernet network (RAS (RemoteAccessServer) function).

Quantum

Setup

1 Atrium slot PLC 2 Ethernet Modbus/TCP card or integrated port 3 TCP/X-Way software gateway

Integration into the host PC To receive a TSX PCI 57 204M/354M Atrium slot PLC, the host PC must: b Run under Windows 2000 or Windows XP b Have a 33-bit 33 MHz (c 5 V or c 3.3 V) PCI bus b Have two consecutive slots available on the PCI bus (of which at least one must be a PCI type slot) The maximum number of slot PLCs per PC depends on the number of available PCI/ISA slots, the PC power supply rating (when the TSX PSI 2010 power supply option is not used) and whether or not PCMCIA cards have been inserted into the slot PLC. The slot PLC is completely independent of the application running on the PC, in particular: b The standard PC command Restart (1) has no effect on the slot PLC operating modes (2). b Switching the PC off and then on again causes a warm restart of the application being managed by the slot PLC (restart without loss of application context). b The TSX PSI 2010 c 24 V standalone power supply allows the slot PLC to operate even in the event of a PC power supply outage. The host PC, equipped with Unity Pro software, can be used as a programming and setup terminal for the TSX PCI 57 Atrium slot PLC. Logical location on bus X

Magelis iPC or PC with: - 1 Atrium slot PLC - and TSX PCI ACC1 faceplate or TSX PSI 2010 power supply

The Atrium TSX PCI 57 204M/354M slot PLC logically occupies the same 2 slots as a Premium TSX 57 processor of the same type. The 2 slots in the TSX RKY ppEX rack with address 0 next to the TSX PSY ppp0M power supply module must therefore remain unoccupied. The TSX PCI ACC1 faceplate or TSX PSI 2010 c 24 V power supply enables a second bus X to be connected from PC Panel Magelis iPC industrial PCs, thus forming a Y structure (see the diagram opposite, where the maximum length of each bus X segment is 100 m). __________________________________________________________________

TSX RKY ppEX rack

TSX RKY ppEX rack

(1)Ctrl-Alt-Delcommand,followedbyRestartorpressingtheResetbuttononthePC(if there is one) . (2) Causes the loss of the PCI bus connection .

Presentation: pages 1/14

Memory structure: pages 1/18

Characteristics: pages 1/20

References: pages 1/21

PCMCIA references: pages 1/22

1/17

Memory structure

Modicon Premium automation platformAtrium slot PLCsUnity

Slot PLC without PCMCIA memory card

1Internal RAM160 to 208 Kb

Located data Global and DFB unlocated data Program, symbols and area for online program modification

1 1 2

2 3160 or 208 Kb

Constants

3

The application memory is divided into memory areas physically distributed in the internal RAM memory and on 0, 1 or 2 PCMCIA memory extension cards: 1 The application data area, which may be one of 2 possible types, is always in the internal RAM: v Located data corresponding to data defined by an address (e.g. %MW237) to which a symbol may be associated (e.g. Counting_rejects). v Global unlocated data corresponding to data defined only by a symbol. This type of addressing removes memory mapping management constraints, as address are assigned automatically, and enables data to be structured. v DFB unlocated data, corresponding to data from DFB user function blocks. The size of this object zone is only limited by the size of the physical internal RAM memory available 1 (160 Kb or 208 Kb). 2 Area in internal RAM or PCMCIA memory card for the program and symbols. In the event of this area being in internal RAM, it also supports the area for modifying the program in online mode (1). This area contains the programs executable binary code and IEC source code. The user selects the type of information to be stored in the slot PLC memory. 3 Constants area in the internal RAM or the PCMCIA memory card (slot no. 0) 4 Storage area for additional data (slot no. 0 or no. 1), e.g. for production data and manufacturing recipes

Memory structure

Slot PLC with PCMCIA memory card in slot no . 0 Located data

1

Internal RAM

Global unlocated data 1 DFB unlocated data

4 5 6 7 8 9 101 1 2Presentation: pages 1/14 PCMCIA card slot no. 0128 to 7168 Kb

1

Program and symbols 2

Memory organization Two memory structures are possible depending on whether the Atrium slot PLC is fitted with 0, 1 or 2 memory extension cards: b Application in internal RAM. In this case, the application is entirely loaded in the PLC slots internal battery-backed RAM (2), the capacity of which depends on the PLC slot model (160 Kb or 208 Kb). b Application in PCMCIA card. In this case, the internal RAM is reserved for application data. The PCMCIA memory card (slot no. 1) contains the program space (program, symbols and constants areas) (768 Kb or 1792 Kb). Certain types of PCMCIA memory card host the data storage area (max. 6976 Kb). Symbols areas The presence of the symbols area with the program area is optional. Having the application symbols database on the memory of the slot PLC means that, when connected to a programming terminal not containing any applications all the elements needed to debug or upgrade this PLC are available within the PLC.(1)IfaPCMCIAcardhasbeeninserted,thememoryusedbyprogrammodificationinonline modeislocatedinthismemorycard(outsidezones2,3and4opposite). (2)TheinternalRAMmemoryisbackedupbyanoptionalbattery(3yearsbatterylife)locatedin the power supply module (see page 2/2) .

Constants Storage of additional data

3 4

__________________________________________________________________

Description: pages 1/16

Characteristics: pages 1/20

References: pages 1/21

PCMCIA references: pages 1/22

1/183

Memory structure (continued)

Modicon Premium automation platformAtrium slot PLCsUnity

Slot PLC with data storage memory card in slot no . 0 Located data Internal RAM160 or 208 Kb

1 1 2 3

Global and DFB unlocated data Program, symbols and area for online program modification Constants

Extension of the data storage area Memory cards reserved for data storage (4096 or 8192 Kb) are used to: b Access the data storage area when the application is entirely supported by the internal RAM. In this case, the data storage memory card is inserted into PCMCIA slot no. 0. b Free up memory space to provide additional program space when the application is in the PCMCIA card (slot no. 0). In this case, the data storage memory card is inserted into PCMCIA slot no. 1 (a part of it can be supported by the memory card in the slot). Unity Pro programming software assists the application designer with the management of the structure and the occupation of memory space on the Atrium slot PLC.

Memory structure (continued)

1 2 3 4 5 6 7 8 9 10

4096 or 8192 Kb

PCMCIA data storage card (slot no. 0)

Storage of additional data

4

Protecting the application Regardless of the slot PLC memory structure (whether the application is located in the internal RAM or in the PCMCIA memory card), it is possible to protect this in order to prevent it being accessed (read or modify program) by only loading the executable code on the slot PLC. A memory protection bit, set in configuration mode, is also available to prevent any program modification (via the programming terminal or downloads). Program modification in online mode This function is different from previous versions of Premium PLCs (with PL7 software) and now allows program code and data in different parts of the application to be added or modified in a single modification session (thus making modification unified and consistent with regard to the controlled process). This increased flexibility comes at a cost in terms of the program memory volume required. Any program modifications made in online mode require available program memory space at least equal in size to the combined size of all sections of the Unity Pro program affected by the same modification session. Depending on circumstances: b For a slot PLC with memory extension card, the memory volume remaining available in the card for online modification is sufficient if the recommendations on page 1/22 are observed. b For a slot PLC without memory extension card, users wishing to have the option of making modifications in online mode may select a processor according to: v The anticipated size of the application v The number and size of the program sections to be modified in online modeNote:AmemoryextensioncardthatonlyusesFlashEpromtechnology(withoutadditional SRAM)cannotprovidethefunctionofprogrammodificationinonlinemode.

Slot PLC with mixed type memory cards in slot no . 0 and data storage type memory cards in slot no . 1160 or 208 Kb

Located data

1

Internal RAM

Global unlocated data 1 Unlocated DFB data

1

128 to 7168 Kb

Program and symbols 2

PCMCIA card (slot no. 0)

Constants

3

Additional data storage 4 (zone A)

PCMCIA data storage card (slot no. 1)

4096 or 8192 Kb

Additional data storage 4 (zone B)

Presentation: pages 1/14

Description: pages 1/16

Characteristics: pages 1/20

References: pages 1/21

PCMCIA references: pages 1/22

1/19

Characteristics

Modicon Premium automation platformAtrium slot PLCsUnity

Characteristics and performance

1 2

Type of processor Maximum No. of racks 4/6/8 slots configuration 12 slots Max. no. of slots for modules Functions Max. no. in Discrete I/O rack of (1) Analog I/O Process control channels No. of applic.-specific ch. Type of applic.-specific ch. Ethernet Fipio manager Serial link

Integrated connections

3 4 5 6 7 8 9 10Memories

Maximum Network no. of (Ethernet, Fipway, Ethway, connections Modbus Plus) AS-Interface bus CANopen or Modbus Plus bus InterBus or Profibus DP bus Maximum Without PCMCIA card Kb capacity With PCMCIA card Kb Data storage Located internal bits (% Mi) Located internal data Global unlocated internal data Kb bit/s Kb Kb

TSX PCI P57 204M TSX PCI P57 354M 16 8 128 1024 80 128 10 (up to 30 simple loops) 15 (up to 60 simple loops) Programmable loops via EFB control blocks (with Unity Pro Large and Extra Large) 24 32 Counter, axis, weighing and serial links (Modbus, Uni-Telway and asynchronous) 1 (uses the Ethernet Modbus/TCP port integrated in the host PC via the TLX CD GTW 10M gateway software) 1 (127 agents) 1 link with 2 connectors (TER and AUX) 1 link with 2 connectors (TER and AUX), 19.2 Kbit/s 19.2 or 115 Kbit/s 2 (including 1 Ethernet Modbus/TCP 4 (including 1 Ethernet Modbus/TCP integrated into host PC) integrated into host PC) 4 8 1 1, none if CANopen is used 3, 2 if CANopen is used 160 program + data 208 program + data 768 program 1792 program 160 data 208 data 16,384 (limited to 8192 with current PCMCIA cards) 8132 16,384 64 for internal words %MpWi, 64 for constant words %KpWi Elementary EDT and derived DDT data: 64 Kb DFB and EFB function blocks: size per instance 64 Kb, unlimited number of instance (within the limits of slot PLCs data memory capacity) 1 1 64 (1 of which has priority) 0.19 0.12 0.25 0.17 1.75...2.60 (2) 0.21 0.42 1.75...2.60 (2) 4.76/ 3.70 (3) 3.71/2.53 (3) 1.00 0.30

Maximum size of object zones Application structure Tasks

Execution time for one instruction

Without PCMCIA card With PCMCIA card

Typical program code execution time for 1 Kinstruction System overhead Tasks

Master Fast Auxiliary Evens Boolean On word or fixed-point arithmetic On floating points Boolean On word or fixed-point arithmetic On floating points 100% Boolean

ms ms ms ms ms

0.17 0.32

ms Kinst/ ms 65% Boolean and 35% fixed Kinst/ arithmetic ms Master ms Fast ms

6.72/4.59 (3) 5.11/3.12 (3) 1.00 0.25

(1)Onlyaffectsin-rackmodules.ThemaximumvaluesforthenumberofdiscreteI/O,analogI/Oandapplication-specificchannelsarecumulative.TheremoteI/O onthebusornetwork(CANopen,AS-Interface/Uni-Telway/Fipio/ModbusPlus,etc.)orthird-partybus(InterBusorProfibusDP)arenotincludedinthis maximum number . (2)Values limited according to the type of instruction (3)ThefirstvaluecorrespondstoexecutiontimewithoutPCMCIAcardandthesecondvaluewithPCMCIAcard.

Standalone power supply characteristicsType of power supply module Primary Voltage Nominal Limits (including ripple) Current Nominal input value 1 rms Initial power- 1 inrush up at 25C I2t on triggering It on triggering Power line disturbance period Built-in protection Conformity to standards Insulation Dielectric Primary/secondary and strength primary/earth V V A A A2 As ms TSX PSI 2010 c 24 c 19.2 30 (possible up to 36 V) y 1.1 at c 24 V 100 at c 24 V 3 0.04 y 7 at 24 V, y 1 at 19.2 V Via a 2 A time-delay fuse (complying with standards) IEC 1131-2 Non-isolated, internal 0 V connected to PC ground

V rms

1/20

References

Modicon Premium automation platformAtrium slot PLCsUnityAtrium slot PLCsI/O capacity (1)

Capacities Memory

TSX PCI 57 20 16 racks (2)1024 discrete I/O 80 analog I/O 24 application-specific channels TSX PCI 57 204M 160 Kb integrated Max. 768 Kb on PCMCIA

Process control channels 10

Maximum number Reference of bus/network modules 1 network all types TSX PCI 57 204M 1 Ethernet network 4 AS-Interface buses 1 CANopen bus (3) 1 fieldbus (3)

Weight kg

1 2

0.310

TSX PCI 57 35 16 racks (2)1024 discrete I/O 128 analog I/O 32 application-specific channels 208 Kb integrated Max. 1792 Kb on PCMCIA 15 1 integrated Fipio TSX PCI 57 354M 3 networks all types 1 Ethernet network 8 AS-Interface buses 1 CANopen bus (3) 3 third-party buses (3) 0.340

3 4 5 6 7 8

TSX PCI 57 354M

PCMCIA memory extension cardsAtrium slot PLCs can support up to 2 memory extension cards. However, useful memory capacity is limited to the maximum size defined for the slot PLC model. References, see pages 1/22 and 1/23.

Software options (4) When connected to an Atrium slot PLC, the TCP/X-Way gateway software offer (supplied on CD-ROM) enables communication under the Modbus or Uni-TE protocol using the Ethernet Modbus/TCP port integrated into the host PC.Description TCP/X-Way gateway software Use Compatible with Windows 2000 or XP Site license Single-station Reference TLX CD GTW 10M Weight kg

Separate partsDescription Use Sold in lots of Reference TSX PCI ACC1 Faceplate for remote bus X Enables a second remote bus X connection (9-way SUB-D connector) c 24 V standalone power supply Weight kg

TSX PCI ACC1

Enables the TSX PCI slot PLC to operate in the event of a PC power supply outage Enables a second remote bus X connection (9-way SUB-D connector) Internal RAM memory of slot PLC backup 1 10

TSX PSI 2010

Batteries

TSX PLP 01 TSX PLP 101

0.010 0.100

TSX PSI 2010

(1) Cumulative maximum values . The number of remote I/O on the bus is not counted . (2) Maximum number of TSX RKY 4EX/6EX/8EXracks(4,6or8slots).UsingtheTSX RKY 12 EX rack with 12 slots is the sameasusing2rackswith4,6or8slots. (3)Fieldbus:InterBusorProfibusDP. (4)OthersoftwarecompatiblewithAtriumslotPLCs:OFSdataserversoftware,seepage6/105; VijeoDesigner/VijeoCitectsupervisorysoftware,seeourcatalogHuman/MachineInterfaces.

9 10

Presentation: pages 1/14

Description: pages 1/16

Memory structure: pages 1/18

Characteristics: pages 1/20

PCMCIA references: pages 1/22

1/21

Presentation

Modicon Premium automation platformPCMCIA memory extension cardsUnity

Presentation

1 2 3 4PCMCIASRAMmemorycard

PCMCIA memory extension cards are used to extend the internal RAM capacity of Premium processors and Atrium slot PLCs. Some of the cards can also be used on Quantum and Micro processors. Depending on the model, these cards can host: b Application program, symbols and constants b Additional application data b Or both PCMCIA memory extension cards All the cards are inserted into PCMCIA slot no. 0 on Premium processors and Atrium slot PLCs, i.e.: b The upper slot on processors b The internal slot on slot PLCs Two of these SRAM data storage memory cards can also be inserted into slot no. 1, i.e.: b The lower slot on processors b The external slot on slot PLCs These cards support three types of data storage: b Application storage: Program, symbols and constants in a common space (128 Kb to 7168 Kb, depending on the card model): v TSX MRP PpppK for SRAM memories v TSX MFP PpppK/M for Flash EPROM memories b Storage of the application and additional data, with 192 Kb to 7 Mb of application space and 7 Mb to 0 Kb of data storage space for additional data. The limit between these 2 spaces is configurable. The configurable cards are: v TSX MRP CpppK/M for SRAM memories v TSX MCP CpppK/M for Flash EPROM and SRAM memories b Storage of additional data, provided by 4 Mb or 8 Mb TSX MRP F00pM SRAM memory cards These cards use 2 technologies: b Battery-backed SRAM Used in particular in the creation and debugging phases for the application program. These cards support: v All of the applications transfer and modification services in online mode v Additional data storage The memory is backed up by a removable battery integrated into the PCMCIA card. A second auxiliary battery is present to enable the main battery to be replaced without loss of data. b Flash EPROM Used once debugging of the application program is complete. It enables: v Backup battery life restrictions to be overcome v A global application transfer to be performed If it is used, the application cannot be modified in online mode. Program modification in online mode

PCMCIASRAMmemorycard

5 6 7 8 9Premium processors Atrium slot PLCs Cards recommended for program modification in online mode

Only extension cards on which the program is stored in SRAM memory (TSX MRP PpppK/M. and TSX MRP CpppK/M) support online program modification. Users of processors fitted with memory extension cards who wish to modify or add program data in online mode must follow the two recommendations below: b Structure the application program in a number of sections of a reasonable size b Where possible, select one of the two extension cards recommended in the table below:TSX P57 Cp TSX P57 0p All TSX MRP PpppK and TSX MRP CpppK/M/7 TSX P57 1p TSX MRP P224K/P384K, all TSX MRP CpppK/M/7 TSX P57 2p TSX P57 3p TSX P57 4p TSX P57 5p TSX P57 6p TSX PCI 57 2p TSX PCI 57 3p All TSX MRP CpppK/M/7 TSX MRP C002M, TSX MRP C003M, TSX MRP C007M

10

1/22

References

Modicon Premium automation platformPCMCIA memory extension cardsUnity

Memory capacities without PCMCIA extension card (data,program,symbols,andconstantsininternalRAMmemory):Premium processors Atrium slot PLCs TSX P57 Cp0244/ 0244M 96 Kb TSX P57 TSX 57 104/154M/ 204/ 1634M 2634M 160 Kb TSX PCI 57 204M TSX P57 254 TSX P57 304/ 3634M TSX P57 354M TSX PCI 57 354M

Reminder of the memory capacities of processors and slot PLCs

In internal RAM Premium processors Atrium slot PLCs

192 Kb TSX PCI 57 204M TSX P57 254 TSX P57 304/ 3634M

208 Kb TSX P57 354M TSX PCI 57 354M

TSX P57 454/ 4634M 440 Kb

TSX P57 554/ 5634M 1024 Kb TSX P57 554/ 5634M 1024 Kb 7168 Kb

TSX P57 6634M 2048 Kb TSX P57 6634M 2048 Kb 7168 Kb

1 2 3 4 5 6 7 8 9 10

Memory capacities with PCMCIA extension card(s) (dataininternalRAMmemory;program,symbols,constants,anddatastorageonPCMCIAcard):TSX P57 0244M TSX P57 TSX 57 104/154M/ 204/ 1634M 2634M 160 Kb 224 Kb 768 Kb TSX P57 454/ 4634M 440 Kb 2048 Kb

Data in internal RAM 96 Kb PCMCIA extension (progr., 128 Kb symbols and constants) Data storage on PCMCIA (1) 256 Kb

192 Kb 768 Kb

1792 Kb

208 Kb 1792 Kb

16,384 Kb, limited to 8192 Kb if the TSX MRP F008M PCMCIA card is used

PCMCIA memory extension cardsPremium TSX P57 Cp/0p/1p/2p/3p/4p/5p/6p processors and Atrium TSX PCI 57 2p/3p slot PLCs support the memory extension cards listed below. There are two types of memory limit: - One associated with the type of processor or slot PLC (see above) - One associated with the model of PCMCIA memory card selected The lowest of these two limits defines the memory capacity available to the user for his/her application. Use on processor Slot Memory size Application Reference Additional data TSX MRP P128K TSX MRP P224K TSX MRP P384K TSX MRP C448K TSX MRP C768K TSX MRP C001M TSX MRP C01M7 TSX MRP C002M TSX MRP C003M TSX MRP C007M TSX MFP P128K TSX MFP P224K TSX MFP P384K TSX MFP P512K TSX MFP P001M TSX MFP P002M TSX MFP P004M TSX MCP C224K TSX MCP C512K TSX MCP C002M TSX MRP F004M TSX MRP F008M TSX MFP B096K Weight kg 0,076 0,076 0,076 0,076 0,076 0,076 0,076 0,076 0,076 0,076 0,044 0,044 0,044 0,044 0,044 0,044 0,044 0,076 0,076 0,076 0,076 0,076

SRAM application memory extensions Slot 0 TSX 57 Cp, TSX 57 0p57 4p TSX PCI 57 2p/3p

128 Kb 224 Kb 384 Kb Configurable SRAM application/additional data memory extensions Slot 0 96448 Kb 3520 Kb TSX 57 Cp, TSX 57 0p57 4p TSX PCI 57 2p/3p 192768 Kb 1921024 Kb 1921792 Kb 1922048 Kb 1923072 Kb 1927168 Kb Flash EPROM application memory extensions Slot 0 128 Kb TSX 57 Cp, TSX 57 0p57 4p TSX PCI 57 2p/3p 224 Kb 384 Kb Slot 0 512 Kb TSX 57 Cp, TSX 57 0p57 6p TSX PCI 57 2p/3p 1024 Kb TSX 57 2p57 6p TSX PCI 57 2p/3p Slot 0 TSX 57 Cp TSX 57 0p57 6p TSX PCI 57 2p/3p Slot 0 5760 Kb 8320 Kb 16000 Kb 18560 Kb 28800 Kb 69760 Kb

2048 Kb 4096 Kb Flash EPROM and SRAM application/additional data memory extensions TSX 57 0p57 4p Slot 0 224 Kb 256 Kb TSX PCI 57 2p/3p Slot 0 512 Kb 512 Kb TSX 57 Cp TSX 57 0p57 6p 2048 Kb 1024 Kb TSX PCI 57 2p/3p SRAM additional data memory extensions TSX 57 2p57 6p Slot 0 or 1 4096 Kb TSX PCI 57 2p/3p (2) 8192 Kb Flash EPROM backup card (3) TSX 57 Cp Slot 0 96 Kb TSX 57 0p/1p

Replacement partsDescription

Use PCMCIA SRAM memory card

Type Main Auxiliary

Reference TSX BAT M02 (4) TSX BAT M03 TSX P CAP

Backup batteries Handle

Remove PCMCIA memory card (provided with the memory card) (1) Intended for the storage of manufacturing recipes and production data . Capacity depending on PCMCIA card model . (2)Memoryextensioncardforfilestoragetobeinsertedintoslotno.0iffree,otherwiseintoslotno.1.Inthelattercase,an applicationmemorytypeorapplicationmemoryandfilestoragetypememoryextensioncardisinsertedintoslotno.0. (3) This card is pre-loaded and can be used to update the application program on a Premium PLC without having to use a programmingterminal(theentireprogrammustbelocatedintheinternalRAM). (4) TSX BAT M02 with PCMCIA card PV u04(blue),forPCMCIAcardPV