automatic entrance systems - absupply.neto n l y a u t o d o r o p e r a t i o n red black red red o...

17
Automatic Entrance Systems ELECTRICAL INSTALLATION MANUAL **SLIDERS** 1510596 Revision 5-18-04 NABCO ENTRANCES INC. Phone: 877-622-2694 Fax: 888-679-3319 Technical Assistance: 1-866-622-8325 http://www.nabcoentrances.com Email: [email protected] WARNING Do not install, operate or service this product unless you have read and understand the Safety Practices, Warnings, Installation and Operating Instructions contained in this man- ual. Failure to do so may result in property damage, or bodily injury. BLUE BLUE RED YELLOW GREEN RED BROWN PLUG WITHBLUE JUMPER MUST BE IN PLACE NOT USED RED YELLOW RED BROWN RED GREEN ORANGE BROWN PLUG WITH BLUE JUMPERMUST BE IN PLACE ACUSENSOR HARNESS PT. NO. 229184 BROWN WIRE NUT BLUE BLACK BLACK BLACK "REDUCE" LEAVE OPEN EMITTER DETECTOR BROWN LIGHT BLUE BROWN BROWN INTERIOR ACUSENSOR PT. NO. 148902 BLACK BLUE EXTERIOR ACUSENSOR PT. NO. 148902 ACUSENSOR HARNESS PT. NO. 229184 Teleco Brand Safety Beams BLUE WHITE RED GREEN BLACK BLUE RED WHITE GREEN BLACK BLACK 120 VAC "HOT" 120 VAC "COMMON" SERVICE GROUND BLACK BLACK WHITE WHITE BLUE BLACK BROWN RED GREEN ORANGE ORANGE SWITCH BOX WIRE NUT WIRE NUT Fo r con t i nued p r o t ec t i on aga i ns t f i re , r ep l ace on l y w i t h a f use o f t he s a m e t ype and r a t i ng . No t U s e d 15 VAC C o mm o n 15 VAC H o t No t U s e d Wh i t e B l ack 1 2 3 4 NO .CO L ORU S E Mo t o r V Pha s e Encode r 12 VDC Encode r A Pha s e Mo t o r U Pha s e Encode r G r ound Encode r B Pha s e U S E R e d O r a ng e B r o w n B l ue B l ack Ye l l ow 1 2 3 4 5 6 NO .CO L OR 12 VDC + 12 VDC - ( C o mm o n ) I n t e r i o r Ac t i va t i on Sen s o r Ho l d i ng B e a m R e du c e d Op e n i ng M o d e Sw i t ch 1 M o d e Sw i t ch 2 Ex t e r i o r Ac t i va t i on Sen s o r A l t e r na t i ng Ac t i va t i on B r eakou t Ou t pu t Sw i t ch H I ( E l ec . Lock , A i r l ock , e t c . ) Ou t pu t Sw i t ch LO ( E l ec . Lock , A i r l ock , e t c . ) B r o w n R e d B l ack Wh i t e G r e n O r a ng e O r a ng e O r a ng e Ye l l ow B l ue V i o l e t G r a y 9 DC 1 2 V 7 61 6 B H M0 M1 62 SQ BA OU T + OU T - 1 2 3 4 5 6 7 8 9 10 11 12 ( Se M o d e Sw i t ch Tab l e ) NO . S YMBO LCO L ORU S E [ SL I DE MOD E S ELECTED ] U S E [ S W I NG MOD E S ELECTED ] ( Se M o d e Sw i t ch Tab l e ) MOD E S W I TCH TABLE MO O p e n G n d G n d O p e n M1 O p e n O p e n G n d G n d M o d e Au t o Ex i t Ho l d O p e n N i gh t N o . 12 VDC + 12 VDC - ( C o mm o n ) Ap r o a c h Ac t i va t i on Sen s o r Ho l d i ng B e a m o r Sw i ng Sen s o r Th r e s ho l d Sa f e t y M a t M o d e Sw i t ch 1 M o d e Sw i t ch 2 Ex t e r i o r Ac t i va t i on Sen s o r A l t e r na t i ng Ac t i va t i on B r eakou t Ou t pu t Sw i t ch H I ( E l ec . Lock , A i r l ock , e t c . ) Ou t pu t Sw i t ch LO ( E l ec . Lock , A i r l ock , e t c . ) VIOLET GRAY YELLOW NOT USED ORANGE NOT USED NOT USED WIRE NUT WIRE NUT WHITE MOTOR OPERATOR MINIMUM 5 AMPERE SERVICE PER OPERATOR GREEN BLACK BLUE BLUE RED BLACK RED RED BLUE BACK SIDE OF SWITCHSHOWN. BLACK WHITE WHITE RED ROCKER SWITCH EXTENSIONHARNESS PT. 229186 MOTORHARNESS AND PLUGS PLUG FOR HANDY TERMINAL

Upload: others

Post on 29-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

AutomaticEntranceSystems

ELECTRICAL INSTALLATION MANUAL**SLIDERS**

1510596 Revision 5-18-04

NABCO ENTRANCES INC.Phone: 877-622-2694 Fax: 888-679-3319Technical Assistance: 1-866-622-8325http://www.nabcoentrances.comEmail: [email protected]

WARNINGDo not install, operate or service this product unless you have read and understand the

Safety Practices, Warnings, Installation and Operating Instructions contained in this man-ual. Failure to do so may result in property damage, or bodily injury.

BLUEBLUE

RED

YELLOW

GREEN

REDBROWN

PLUG WITH BLUE JUMPER MUST BE

IN PLACE

NOT USED

RED

YELLOWREDBROWN

RED

GREEN

ORANGEBROWN

PLUG WITH BLUEJUMPER MUSTBE IN PLACE

ACUSENSORHARNESS

PT. NO. 229184

BROWN

WIRE NUT

BLUE

BLACK

BLACK

BLACK"REDUCE"

LEAVE OPEN

EMITTERDETECTOR

BROWN

LIGHT BLUEBROWN

BROWN

INTERIOR ACUSENSORPT. NO. 148902

BLACK

BLUE

EXTERIOR ACUSENSORPT. NO. 148902

ACUSENSOR HARNESS

PT. NO. 229184

Teleco Brand Safety Beams

BLUEWHITERED

GREENBLACK

BLUE

REDWHITE

GREENBLACK

BLACK 120 VAC "HOT"120 VAC "COMMON"SERVICE GROUND

BLACK

BLACK

WHITE

WHITE

BLUE

BLACKBROWNREDGREENORANGEORANGE

SWITCH BOX

WIRE NUT

WIRE NUT

CAUTION For continued protectionagainst fire, replace onlywith a fuse of the sametype and rating.WARNING

Not Used115 VAC Common115 VAC HotNot UsedWhiteBlack1234NO.COLORUSEMotor V PhaseEncoder 12 VDCEncoder A PhaseMotor U PhaseEncoder GroundEncoder B PhaseUSERedOrangeBrownBlueBlackYellow123456NO.COLOR12 VDC+12 VDC - (Common)Interior Activation SensorHolding BeamReduced OpeningMode Switch 1Mode Switch 2Exterior Activation Sensor Alternating ActivationBreakoutOutput Switch HI (Elec. Lock, Airlock, etc.)Output Switch LO (Elec. Lock, Airlock, etc.)

BrownRedBlackWhiteGreenOrangeOrangeOrangeYellowBlueVioletGray9DC12V7616 BHM0M162SQBAOUT +OUT -123456789101112 (See Mode Switch Table)NO.SYMBOLCOLORUSE [ SLIDE MODE SELECTED ]USE [ SWING MODE SELECTED ](See Mode Switch Table)MODE SWITCH TABLEMOOpenGndGndOpenM1OpenOpenGndGndModeAutoExitHold OpenNight

No.Fuse Inside

Rating: 125V, 5ASize: 5.2 x 20mm1. Adjustments to the door can only be made with a Handy Terminal.

No adjustments are available inside the control box.2. Replaceable fuse located inside the control box.3. Turn the power off prior to removing the cover.4. This unit can not be repaired in the field. Any attempted repairs

by an unauthorized NABCO facility will void the warranty.

N A B C O 2 4 8 9 0 1 M i c r o p r o c e s s o r C o n t r o l l e r 12 VDC+12 VDC - (Common)Approach Activation SensorHolding Beam or Swing SensorThreshold Safety MatMode Switch 1Mode Switch 2Exterior Activation SensorAlternating ActivationBreakoutOutput Switch HI (Elec. Lock, Airlock, etc.)Output Switch LO (Elec. Lock, Airlock, etc.)Power Connector (4 pin)

Motor Connector (6 pin)

Handy Terminal Connector (6 pin)Main Harness Connector (12 pin)

VIOLETGRAYYELLOW NOT USED

ORANGE

NOT USEDNOT USED

WIRE NUT

WIRE NUTWHITE

MOTOR

OPERATOR

MINIMUM 5 AMPERE SERVICEPER OPERATOR

GREEN

BLACKBLUE

BLUE

ON

O N E W A Y

R E D U C E D O P E N

H O L D O P E NF U L L O P E N

ON

LY

AU

TO

DO

OR

OP

ER

AT

ION

RED

BLACKRED

RED

OF

F

N I G H T

BLUE

BACK SIDE OFSWITCH SHOWN.

BLACK

WHITE

WHITE

REDROCKER SWITCH EXTENSION HARNESSPT. 229186

MOTOR HARNESS AND PLUGS

PLUG FOR HANDY TERMINAL

Page 2: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 2 -

Table of Contents

Electrical Information Page 3

Typical Slider Wiring Page 4

Microprocessor Controller Page 5-6

Dual Operator Wiring Diagrams Page 7

Acusensor/Acumotion Page 8

How Door Function Modes are Achieved via the Rocker Switches Page 9

Holding Beams (Activation—Hold Open) Page 10

Holding Beam (Breakout—Power Interrupt) Page 11

Diagram for connecting push plates and or card readers for Night mode. Page 12

Electric Locks—Fail Safe Page 13

Electric Locks—Fail Secure Page 14

Troubleshooting Page 15-17

Page 3: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 3 -

Electrical Information

Note: Since the Model 1175 Slider is predominantly wired at the factory the site installer/electrician has a relatively simple task.

1. Convenient electric service access holes have been provided in the slide header end caps and jamb tubes. An installer/electrician should route 120 VAC, single phase, 5 AMP (MINIMUM) power to the factory sup-plied and mounted junction box in the header.

2. The installer/electrician should connect one power hot lead (Black) to the power cut off switch mounted inside the junction box. Utilizing an ap-propriate wire nut, the installer/electrician should connect the common lead (White) to the loose common lead (White) found inside the junction box. The ground wire should be connected to the ground screw located in the back of the switch junction box.

3. Replace the junction box cover. The unit’s power should now be activated through the building’s electrical circuit breaker box. Proceed with performance set-up procedures outlined in the Mi-croprocessor and Handy Terminal Manual p/n 159000

WARNINGDisconnect all power to the junction box prior to making any electrical connections. Wiring must meet all local, state, federal or other governing agency codes. Failure to do so may result in serious personal or fatal injury.

Factory Wiring

GroundHot

Common

DN 0006

Page 4: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 4 -

Typical Slider Wiring

Wiring diagrams are included in the back of this manual, which reflect the typical primary and secondary circuits installed at the factory. The low voltage (12 VDC) Reed switch (panic break away) and Acusensor are easily connected on site using factory installed connector housings. The factory uses Underwriters Laboratories’ (UL) recognized component wire, terminals and connector housings to manufacture the slider. Contact the Customer Service Department for assistance with special applications.

WARNINGMicroprocessor controller contains HIGH VOLTAGE! Installation should be performed by qualified personnel only. Wiring must meet all local, state, federal or other governing agency

codes. Failure to do so may result in serious personal or fatal injury.

General Wiring Diagram

BACK SIDE OFSWITCH SHOWN.

SW. EXT.HARNESS

PT. NO. 22-9220

SW. EXT.HARNESS

PT. NO. 22-9220

WHITEWHITE

PLUG WITH BLUE JUMPER

MUST BE IN PLACE

PN 120324

HOLDING BEAM CONNECTOR. USE

ONLY WITHHOLDING BEAMS!

ACUSENSOR EXTENSION HARNESS

PT. NO.22-9267RED

Yel

Gray Gray

Yel

RED

ACUSENSOR EXTENSION HARNESS

PT. NO.22-9267

RED

ACUSENSOR HARNESSPT. NO. 229184

BLACK

GREENWHITE

EXTERIOR ACUSENSORPT. NO. 148902

MAGNETIC POWER DOWN SWITCH PT.

NO. 229222

MAGNETIC POWER DOWN SWITCH PT.

NO. 229222

HANDING HARNESSPT. NO. 11-9208

RIGHT HAND UNITS ONLY

MTR. HARNESS

& PLUG

Microprocessor ControllerPT. NO. 24-8901

PN 219821-01

2110097 Telescopic Operator219528 1175 Slider Operator

Telescopic units only.Second pulley for

PLUG FOR HANDY TERMINAL

U16 and later models.New Switch

BROWNORANGE

RED

GREEN

BROWN +12 VDC

PT. 229186EXTENSION HARNESSROCKER SWITCH

BLACKGREEN

REDWHITEBLUE

WHITE

PT. NO. 148902INTERIOR ACUSENSOR

WHITEGREEN

BLACK

PT. NO. 229184ACUSENSOR HARNESS

GREEN

RED

WHITE

BLUE

REDREDBLUEBLUE

Red

White

White

Black

Red

Blue

Red

Green

Red

OPEN

FULL

HOLD OPEN

ONE WAY

TWO

WAY

NIGHT

OFF

REDUCED OPEN

ON

Green

Black

White

Black

Blue

Red

BLACKGREEN

WHITERED

BLUE

WIRE NUT

WIRE NUT

PER OPERATORMINIMUM 5 AMPERE SERVICE

USED FOR ELECTRIC LOCKUSED FOR ELECTRIC LOCKUSED FOR SEQUENTIAL OPERATION

WHITE

OPERATOR

MOTOR

ORANGE 62

YELLOWGRAYVIOLET

Handy Terminal Connector (6 pin)

M o t o r C o n n e c t o r (6 p i n )

P o w e r C o n n e c t o r ( 4 p i n )

S i z e : 5 .2 x 2 0 m mR a t i n g : 1 2 5 V , 5A

F u s e Ins ide

N o .

C O L O RS Y M B O LN O .

12

11

10

9

8

7

6

5

4

3

2

1

O U T -

O U T +

BA

SQ

62

M1

M0

H

6 B

61

7

9 D C 1 2 V

G r a y

V i o l e t

B l u e

Y e l l o w

O r a n g e

O r a n g e

O r a n g e

G r e e n

W h i t e

B l a c k

R e d

B r o w n

C O L O RN O .

6

5

4

3

2

1

Y e l l o w

B l a c k

B l u e

B r o w n

O r a n g e

R e dU S E

E n c o d e r B P h a s e

E n c o d e r G r o u n d

M o t o r U P h a s e

E n c o d e r A P h a s e

E n c o d e r 1 2 V D C

M o t o r V P h a s e

U S EC O L O RN O .

4

3

2

1

B l a c k

W h i t e

N o t U s e d

1 1 5 V A C H o t

1 1 5 V A C C o m m o n

N o t U s e d

W A R N I N G

t y p e a n d r a t i n g .

w i th a f u s e o f t h e s a m e

a g a i n s t f i re , r e p l a c e o n l yF o r c o n t i n u e d p r o t e c t i o n

C A U T I O N

WIRE NUT

WIRE NUT

SWITCH BOX

ORANGE M1ORANGE M0GREENREDBROWNBLACK

BLUE

WHITE

GREEN

WHITE

BLACK

BLACK

SERVICE GROUND

120 VAC "COMMON"

120 VAC "HOT"BLACK

DN 0001

WHITE

WHITE

OFF

NIGHT

RED

RED

BLUE

BLACK

RED

RED

BLACK

DOO

R O

PERATIO

NAU

TOO

NLY

FULL OPENHOLD OPEN

REDUCED OPEN

BLACKGREEN

WHITERED

ONE WAY

ON

BLUE

SWITCH SHOWN.BACK SIDE OF

U16 and earlier models.Old Switch

Page 5: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 5 -

By

alte

rnat

ely

switc

hing

the

two

MO

& M

1 (o

rang

e w

ires)

on

the

mic

ropr

oces

sor h

arne

ss to

RED

(com

mon

) the

var

ious

doo

r mod

es su

ch a

s H

OLD

OPE

N m

ode,

EX

IT m

ode,

NIG

HT

mod

e et

c. a

re a

chie

ved.

(Off

= no

t sw

itche

d to

com

mon

On

= sw

itche

d to

com

mon

)Bl

ue (B

A) w

ire m

ust r

emai

n tie

d to

Red

(Com

mon

) for

doo

r to

func

tion.

Refe

r to

Page

9 fo

r mor

e in

form

atio

n

Inte

rnal

1

Amp

Rel

ay

DN

0010

All

volta

ges

show

n m

easu

red

with

resp

ect t

o R

ed (C

omm

on)

Aux

iliary

O

utpu

t(th

is s

witc

h ac

ts li

ke a

do

or

sequ

ence

r)

Sequ

entia

l W

all S

witc

hH

oldi

ng B

eam

sN

.O. c

onta

cts

Exte

rior S

enso

rN

.O. c

onta

cts

Inte

rior S

enso

rN

.O. c

onta

cts

12 V

DC

@ n

o Ac

tivat

ion

0 VD

C @

Act

ivat

ion

12 V

DC

@ n

o Ac

tivat

ion

0 VD

C @

Act

ivat

ion

12 V

DC

@ n

o Ac

tivat

ion

0 VD

C @

Act

ivat

ion

Red

(Com

mon

)

ON

/OFF

R

ocke

r Sw

itch

Pani

cBr

eako

ut /

Stop

C

ircui

t

Logi

c C

ircui

t

Logi

c C

ircui

t

Red

uced

O

peni

ng

Pan

ic B

reak

out S

witc

h (n

orm

ally

clo

sed

cont

acts

)

0 VD

C if

Pan

ic C

ircui

t Clo

sed

and

Roc

ker S

witc

h Tu

rned

"ON

"12

VD

C if

Pan

ic C

ircui

t Ope

n or

Roc

ker S

witc

h Tu

rned

"OFF

"

+12

VDC

Slid

er S

chem

atic

Wiri

ng D

iagr

am -

U04

and

Hig

her M

icro

proc

esso

r

Blu

e

Nab

co "

U"

Serie

s M

icro

proc

esso

r

Roc

ker S

witc

h Ba

nk

Ora

nge

(M0)

Ora

nge

(M1)

Red

(7)

Viol

et (o

ut+)

Yello

w(S

Q)

Gra

y(ou

t-)

Gre

en (H

)

Blue

(BA

)

Blac

k (6

1)

Brow

n (9

DC

12V

)

Whi

te (6

B)

Ora

nge

(62)

Pan

ic B

reak

out S

witc

h (n

orm

ally

clo

sed

cont

acts

)

Pan

ic B

reak

out S

witc

h (n

orm

ally

clo

sed

cont

acts

)

PN 2

4980

1

Microprocessor Controller

Page 6: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 6 -

Microprocessor Controller

The Microprocessor controller has been designed to control the numerous operating characteristics of the slide door system including speed, recycling and door opening width. It will need to be programmed after the installation is complete. (See the Microprocessor Manual p/n 159000 for more details).

CAUTION:Read and understand the Microprocessor Manual p/n 159000 before attempting to

power-up the door. Failure to do so may result in damage to the door and/or injury to the installer and will nullify all warranties.

Microprocessor Main Harness Diagram

Bla

ck

Yell

owB

lue

Pur

ple

Gre

y

Ora

nge

M1

Bro

wn

Red B

lack

Ora

nge

MO

Gre

enW

hite

Whit

eBl

ack

Blu

eG

reen

Ora

nge

MO

Ora

nge

M1

Red

Bro

wn

CN

4

Red

Red

Gre

en

Bro

wn Re

d

Roc

ker

Sw

itch

Con

nect

or

Blue

Blue

Blac

kG

reen

Blue

Whi

teRe

d

Mot

or P

lugCN

2

M.C

.

CN

1

Red

Gre

enR

ed

Blue

Red

ON

RE

DU

CE

D O

PE

N

OFF

NIGH

T

TWO WAY

ON

E W

AY

HOLD

OPE

N

Red

Blac

k

Whi

te

Whi

teBl

ack

FULLOPEN

Red Blue Gre

en

Blac

k

Whi

te

Hol

ding

Bea

m C

onne

ctor

Red

Blue

Bre

akaw

ayC

onne

ctor

s

BlueR

ed

Blu

e

Inte

rior A

ccus

enso

rC

onne

ctor

Whit

e

Whit

e

Whit

e

Whit

e

Whit

e

Whit

e

Whi

te

Blac

k

Gro

und

Whit

e

120

VA

C

HO

LD O

PE

N

FULL

Bla

ck

Bla

ck

Red

Gre

enR

ed

Whit

e

Blue

Red

Red

AUTO

NIG

HT

ON

Blue

D O O R O P E R A T I O NO N L Y

O F F

RE

DU

CE

D O

PE

N

Whi

te

ON

E W

AY

Mai

n B

reak

erS

witc

hin

Hea

der

DN

000

2

CN

3

Han

dyT

erm

inal

Con

nect

or

Red

Bro

wn O

rang

e

Ora

nge

Yello

wG

reen

Blue

Whi

teR

edYe

llow

Blac

k

Blu

e

Ora

nge

62

Roc

ker S

witc

h E

xten

sion

Har

ness

PN

229

186

Roc

ker S

witc

hes

(Old

)U

16 a

nd e

arlie

r mod

els.

Bac

ksid

e of

bot

hsw

itche

s sh

own.

Roc

ker S

witc

hes

(New

)U

16 a

nd la

ter m

odel

s.P

N 2

1982

1-01

NO

TE

: In

som

e ca

ses

the

inte

rior

and

exte

rior A

ccus

enso

rs a

re re

vers

ed

Ext

erio

r A

ccus

enso

rC

onne

ctor

Blu

eR

ed

Whit

e

Gre

en

Bla

ck

Page 7: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 7 -

NOT

USED

NOT

USED

HARN

ESS

FO

R SL

IDE

RSI

MUL

TAN

EO

US P

AIR

P/N:

215

901

ROC

KER

SW

ITC

HES

P/N:

219

821-

01

CAUT

ION

USE

[SLI

DER/

SWIN

GER

]

For

cont

inued

pro

tect

ionag

ainst

fire

, re

place

only

with

sam

e ty

pe a

nd r

ating

of f

use.

WAR

NING

1 2 3 4

COLO

R

WHI

TEBL

ACK

NO.

USE

EMPT

Y

115V

AC H

OT

EMPT

Y

1 2 3 4 5 6

ORA

NGE

RED

BRO

WN

YELL

OW

COLO

RNO

.US

E

115V

AC C

OM

MO

N

MO

TOR

V PH

ASE

ENCO

DER

A PH

ASE

MO

TOR

U PH

ASE

ENCO

DER

GND

ENCO

DER

B PH

ASE

1 2 3 4

7 61 6B

NO. 9D

C12V

COLO

RSY

MBO

L BRO

WN

RED

BLAC

KW

HITE

12VD

C +

12VD

C -,

COM

MO

NAP

PRO

ACH

5H

GRE

EN

6 7 8 9 10 11 12

M0

M1

62 BA OUT

+O

UT -

ORA

NGE

ORA

NGE

ORA

NGE

YELL

OW

BLUE

VIO

LET

GRA

Y

SQ

OUT

PUT

-O

UTPU

T +

SEQ

UENT

IAL

APPR

OAC

H(TH

ROUG

H)

REDU

CED

OPE

NING

/SAF

ETY

MAT

THRE

SHO

LD S

ENSI

NG /

PRES

ENCE

SEN

SOR

MO

DE S

W1

MO

DE S

W2

BREA

K O

UT

BLUE

BLAC

K

GYRO

TECH

- 248

901.10

POW

ER S

OUR

CE (

4P)

OPE

RATO

R (6

P)FU

SE

INSI

DERA

TING

:125

V, 4

ASI

ZE:5

.2 x

20m

m

HAND

Y TE

RMIN

AL (

6P)

SENS

OR

(12P

)

1.Ple

ase

adjus

t th

is op

erat

or a

s pe

r ins

truc

tion

man

ual.

2.Tu

rn t

he p

ower

off

, be

fore

ope

ning

the

box.

3.Do

n't o

pen

this

box

exce

pt f

or r

eplac

ing f

use.

O

ther

wise,

the

war

rant

y will

be t

erm

inate

d.4.

Repa

ir of

this

unit

exc

ept

by N

abco

Ent

ranc

es,

Inc.

m

ay c

ause

sof

twar

e an

d ha

rdwa

re m

alfun

ction

.

CAUT

ION

USE

[SLI

DER/

SWIN

GER

]

For

cont

inued

pro

tect

ionag

ainst

fire

, re

place

only

with

sam

e ty

pe a

nd r

ating

of f

use.

WAR

NING

1 2 3 4

COLO

R

WHI

TEBL

ACK

NO.

USE

EMPT

Y

115V

AC H

OT

EMPT

Y

1 2 3 4 5 6

ORA

NGE

RED

BRO

WN

YELL

OW

COLO

RNO

.US

E

115V

AC C

OM

MO

N

MO

TOR

V PH

ASE

ENCO

DER

12VD

CEN

CODE

R A

PHAS

EM

OTO

R U

PHAS

EEN

CODE

R G

NDEN

CODE

R B

PHAS

E

1 2 3 4

7 61 6B

NO. 9D

C12V

COLO

RSY

MBO

L BRO

WN

RED

BLAC

KW

HITE

12VD

C +

12VD

C -,

COM

MO

NAP

PRO

ACH

5H

GRE

EN

6 7 8 9 10 11 12

M0

M1

62 BA OUT

+O

UT -

ORA

NGE

ORA

NGE

ORA

NGE

YELL

OW

BLUE

VIO

LET

GRA

Y

SQ

OUT

PUT

-O

UTPU

T +

SEQ

UENT

IAL

APPR

OAC

H(TH

ROUG

H)

REDU

CED

OPE

NING

/SAF

ETY

MAT

THRE

SHO

LD S

ENSI

NG /

PRES

ENCE

SEN

SOR

MO

DE S

W1

MO

DE S

W2

BREA

K O

UT

BLUE

BLAC

K

GYRO

TECH

- 248

901.10

POW

ER S

OUR

CE (

4P)

OPE

RATO

R (6

P)FU

SE

INSI

DERA

TING

:125

V, 4

ASI

ZE:5

.2 x

20m

m

HAND

Y TE

RMIN

AL (

6P)

SENS

OR

(12P

)

1.Ple

ase

adjus

t th

is op

erat

or a

s pe

r ins

truc

tion

man

ual.

2.Tu

rn t

he p

ower

off

, be

fore

ope

ning

the

box.

3.Do

n't o

pen

this

box

exce

pt f

or r

eplac

ing f

use.

O

ther

wise,

the

war

rant

y will

be t

erm

inate

d.4.

Repa

ir of

this

unit

exc

ept

by N

abco

Ent

ranc

es,

Inc.

m

ay c

ause

sof

twar

e an

d ha

rdwa

re m

alfun

ction

.

A B

Bla

ck(6

1)W

hite

(6B

)G

reen

(H)

Ora

nge(

M0)

Ora

nge(

M1)

Ora

nge(

62)

Blu

e(B

A)

Red

(7)

Vio

let(O

UT+

)

Bro

wn(

9DC

12V

)

Gra

y(O

UT-

)

Yel

low

(SQ

)

Bla

ck(6

1)W

hite

(6B

)G

reen

(H)

Ora

nge(

M0)

Ora

nge(

M1)

Ora

nge(

62)

Blu

e(B

A)

Red

(7)

Vio

let(O

UT+

)

Bro

wn(

9DC

12V

)

Gra

y(O

UT-

)

Yel

low

(SQ

)

RE

D

BR

OW

NB

RO

WN

RE

D

GR

EE

NO

RA

NG

E(6

2)

RE

DW

HIT

E

RE

D

RE

DW

HIT

E

RE

D

RE

DR

ED

BR

OW

NB

RO

WN

BLA

CK

RE

D

BR

OW

NB

RO

WN

RE

D

GR

EE

NO

RA

NG

E(6

2)

LAB

EL

B

LAB

EL

B

LAB

EL

A

C

124 3

2 12 1 124

124 3

21

21

D2

2

BLU

EB

LUE

BLU

EB

LUE

BLU

E

RE

DR

ED

1

1

2 41 3 5

2 41 3 5

21

21

21

21

GR

EE

NG

RE

EN

OR

AN

GE

(M1)

OR

AN

GE

(M0)

BLU

EB

LUE

Bre

akou

t Sw

itch

B s

ide

door

4/1/

2004

RE

DR

ED

BR

OW

NB

RO

WN

BLA

CK

BLU

EB

LUE

BLU

EB

LUE

LAB

EL

A

2 41 3 5

21

21

2 41 3 5

124

21

21

21

21

BLU

EB

LUE

GR

EE

NG

RE

EN

OR

AN

GE

(M1)

ON

REDU

CED

OPE

N

OFF

NIG

HT

T W O W A Y

ONE

WAY

HOLD

OPE

N

F U L LO P EN

DU

AL

OP

ER

ATO

R W

IRIN

G D

IAG

RA

M

DN

0071

Bre

akou

t Sw

itch

A s

ide

door

MIC

ROPR

OCE

SSO

R CO

NTR

OLL

ER

(MC

)(w

ith s

pecia

l har

ness

) P

/N: 2

4890

1

Plug

bot

h Br

eako

ut S

witc

hes

#229

222

into

MC

Harn

ess

#218

901

at D

Rec

epta

cle

of H

arne

ss #

2159

01.

If th

is is

not

follo

wed,

Br

eako

ut w

ill n

ot fu

nctio

npr

oper

ly.

OR

AN

GE

(M0)

BLU

E

RE

DR

ED

AC

US

EN

SO

R(IN

TER

IOR

SID

E)

AC

US

EN

SO

R(E

XTE

RIO

R S

IDE

)

AC

US

EN

SO

R(IN

TER

IOR

SID

E)

AC

US

EN

SO

R(E

XTE

RIO

R S

IDE

)

A do

or s

top

is n

eede

d at

the

cent

er o

f the

hea

der t

o st

opth

e do

ors

inde

pend

ently

.

ENCO

DER

12VD

C

Plug

Roc

ker S

witc

h #2

1982

1-01

into

MC

Harn

ess

#218

901

at C

Rec

epta

cle

of #

2159

01ha

rnes

s.

If th

is is

not

follo

wed

, Br

eako

ut w

ill n

ot fu

nctio

nan

d th

e Br

eako

ut S

witc

hes

#229

183

may

wel

d sh

utan

d ne

ed to

be

repl

aced

.

Bre

akou

t Sw

itch

Har

ness

Ext

ensi

on22

9220

-00

MIC

ROP

ROCE

SSO

R C

ONT

RO

LLER

(MC)

(with

spe

cial h

arne

ss)

P/N

: 24

8901

JUM

PER

PLU

G F

OR

SIM

ULTA

NEO

US P

AIR

P/N:

119

826

Dual Operator Wiring Diagram

Page 8: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 8 -

ACUSENSOR/ACUMOTIONThe header is wired from the factory so that the activation circuitry on the exterior sensor is turned off in One Way Traffic Mode (the safety circuitry remains active and can not be turned off). The exterior sensor is located on the side of the header in the direction of panic or panel breakout. This can easily be reversed in the field by swapping the connectors where each sensor plugs into the main harness.

1

234

Red

Yellow

Red

Red

Black

White

Green

Black

White

Green

1234

1234

Acusensor Harness (#229184)

1

234

1234

Acusensor Harness (#229184)

RedBlack

White

Green

Green

White

BlackRed

Brown

GrayGray

1234

Yellow

Yellow

4

321 1

234

Red

YellowGray

Acusensor Extension Harness(#229267-01 48" Long)(#229267-02 24" Long)

4

321 1

234

Red

YellowGray

Acusensor Extension Harness(#229267-01 48" Long)(#229267-02 24" Long)

4

321

4

32

1

Brown

Orange

GreenRed

Brown

Red

Black

or

Main Harness

4

321

432

1

Main Harness

Brown

Orange

GreenRed

Brown

Red

Black

or

DN 0003

ExteriorSensor

InteriorSensor

ExteriorSensor

InteriorSensor

AcusensorPN 148902

Acumotion1410364

Page 9: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 9 -

OFF OFF Auto Mode. Both sensor signals are available Electric Lock is always unlocked.

OFF ON Night Mode. None of the sensor signals will be accepted. Sensors will provide threshold safety and electric lock is always locked. Activation must occur by means of an exterior activation device such as a card reader or key switch.

ON ON Hold Open Mode. The door keeps the full open point, not affected by sensors. Electric Lock is always unlocked.

ON OFF One Way Traffic. The interior sensor activates the door; the exterior sensor provides threshold safety. Electric Lock is locked until an interior activation is received

MODE SWITCH TABLEMO M1 ModeOFF OFF Automatic ModeOFF ON Night ModeON ON Hold Open ModeON OFF One Way Mode

The table at right summarizesthe functions as outlined above:

MO M1 Results

How Door Function Modes are Achieved via the Rocker SwitchesBy alternately switching the two MO & M1 (orange wires) on the microprocessor harness to RED (common) the various door modes such as HOLD OPEN mode, EXIT mode, NIGHT mode etc. are achieved. Refer to the tables below.

(Off = not switched to common On = switched to common)

Page 10: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCO ENTRANCES INC www.nabcoentrances.com - 10

Holding Beams (Activation—Hold Open) The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are flush mounted in door frames and/or jamb tubes, facing each other along the threshold. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam will switch the White holding beam input wire to Red (Common). This will cause the system to re-activate and hold open until the interruption is cleared.

13 Yellow 12 G

ray 11 Yellow 10 G

ray 9 Yellow 8 B

lue 7 Yellow 6 B

lue

Brown

Green

Blue

RedBlue

Brown

Black

Blue

Green

Red

White

Red

Orange

YellowJacket color

ConnectEach Terminal

the Same

BraidedShield

Plastic Conductor

Optex Controller and One RCVR & One TRANSPT. NO. 149710-01

EMTR 1Gray

BlueRCVR 2

RCVR 1Blue

EMTR 2Gray

Brown

Red

Optex OS-10CController

Red

Term # & Color

Not used

Exterior Motion Sensor

Interior Motion Sensor

Panic Breakout Switch or Plug with

Blue Jumper connects

here.

Panic Breakout Switch or Plug with

Blue Jumper connects

here.

Panic Breakout Switch or Plug with

Blue Jumper connects

here.

PN 15-10288DN 0004

Terminal #6

Terminal #1

Terminal #13

Terminal #5

Optex OA-10C Beams on a GT-1175Wiring Diagram for Holding Beams(U04 and Higher)

Page 11: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 11

Holding Beam (Breakout—Power Interrupt)The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are flush mounted in door frames and/or jamb tubes, facing each other. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam by breaking out a door panel will interrupt the blue wire power down loop. This will cause the system to stop operating until the door panel is repositioned and latched.

Term # & Color

Panic Breakout Switch or Plug with

Blue Jumper connects

here.

Holding Beams

Panic Breakout Switch or Plug with

Blue Jumper connects

here.

Interior Motion Sensor

Exterior Motion Sensor

Optex Controller and One RCVR & One TRANSPT. NO. 149710-01

PN 15-10287DN 0005

Terminal #5Terminal #1

Terminal #13Terminal #6

Optex OA-10C Beams on a GT-1175Wiring Diagram for Breakout Beams(U04 and Higher)

Plastic ConductorShieldBraided

the SameEach Terminal

Connect

Jacket color Yellow

13 Yellow 12 G

ray 11 Yellow 10 G

ray 9 Yellow 8 Blue 7 Yellow 6 Blue

GrayEMTR 1

Optex OS-10CController

BlueRCVR 1

Red Jumper

Orange

Red

RedBrown

White

Red

Green

Blue

Black

BlackBlue

Brown

PT. NO. 1110187Hold Beam Pigtail

BlueRed

Blue

Green

Brown

Page 12: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 12

Diagram for connecting push plates and or card readers for Night mode.Attach the normally open contacts across the red and black wire on either the rocker or key switches.

HOLD

OPE

N

FULL

Blac

k

Blac

k

Red

Gre

enR

ed

Whi

te

Blue

Red

Red

AUTO

NIG

HT

ON

DO O R O PERATIO NO N L Y

O FF REDU

CED

OPEN

Whi

te

ON

E W

AY

Blue

Blu

eG

reen

Ora

nge

MOOr

ange

M1

Red

Blue

Whi

te

Gree

n

Whi

te

Gree

n

Whi

te

Gree

n

Roc

ker

Switc

hC

onne

ctor

Blue

Blu

e

Blue

Red

Blue

Blac

k

Blac

k

Red G

reen

Whi

te

Blue

Red

Gre

enRe

d

Blue

Red

ON

RE

DU

CE

D O

PE

N

OFF

NIG

HT

TWO WAY

ON

E W

AY

HOL

D O

PE

N

Red

Blac

k

Whit

e

Whit

eBl

ack

FULLOPEN

Red

Blue Gre

en

Blac

k

Whit

e

RE

DU

CE

D

Red

Whi

te

Bla

ckG

reen

Blu

e

Push

but

tom

sw

itch

durin

g ni

ght m

ode.

Red (

#1)

Whi

te (#

6)Bl

ack

(#2)

Red

(#8)

Gree

n (#

1)B

lue (

#4)

Push

but

tom

sw

itch

durin

g ni

ght m

ode.

Push

but

tom

sw

itch

durin

g ni

ght m

ode.

DN

000

7

OLD

ROCK

ER S

WIT

CHU1

6 an

d ea

rlier

mod

els.

NEW

ROC

KER

SWIT

CHU1

6 an

d la

ter m

odel

s.PN

219

821-

01

KEY

SWIT

CHPN

219

820

H.O

.N

IGH

T

FULL

STO

P

AU

TOE

XIT

Clos

ing

cont

acts

with

doo

rin

NIG

HTm

ode

open

sdo

or.

Brea

kaw

ayC

onne

ctor

s

Back

side

of s

witc

h.

1175

Micr

opro

cess

or W

ire D

iagr

amAc

tivati

on w

ith N

ight

mod

e.Co

nnec

t car

d re

ader

and w

all pl

ateno

rmall

y ope

n dry

cont

acts

as s

hown

.Ac

cess

in th

e hea

der.

Back

side

of s

witc

h.

Page 13: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 13

MO

V10

1576

RELA

Y(DC

12V)

2292

40

RECT

IFIE

R11

9929

-01

AC24

V

TRAN

SFO

RMER

(GRN

)

AC11

5V (Y

EL)

(BLK

/WHT

)ELEC

TRIC

LO

CK /

STRI

KE

Fail

Safe

Type

(BLK

/WHT

)

ON O

PEN

>>>

CLO

SECL

OSE

D

LOCK

EDUN

LOCK

ED (O

N)

ACTI

VATE

SIGN

AL

DOOR

OUTP

UTSI

GNAL

time

delay

(0.2

5~1s

ec)

time

delay

(0.2

5~1s

ec)

CLO

SED

LOCK

EDHa

ndy

Term

inal

: Au

x. O

utpu

t [0]

, tim

e de

lay

[0]~

[3]

Mod

e In

put :

One

Way

Tra

ffic

Mod

e or

Nig

ht M

ode

(OR)

(OR)

OUT

+ (V

IOLE

T)

OUT

- (G

RAY)

7 (R

ED)

Wire

Nut

1031

25N

o.

MIC

ROPR

OCES

SOR

CON

TROL

LER

GY

RO

TE

CH

- 2

4890

1H

AND

Y TE

RM

INAL

(6P)

SEN

SOR

(12P

)

1.Pl

ease

adj

ust t

his

oper

ator

as

per i

nstru

ctio

n m

anua

l.2.

Turn

the

powe

r off,

bef

ore

open

ing

the

box.

3.Do

n't o

pen

this

box

exc

ept f

or re

plac

ing

fuse

.

Othe

rwis

e, th

e wa

rrant

y will

be

term

inat

ed.

4.Re

pair

of th

is u

nit e

xcep

t by L

anso

n In

dust

ries,

Inc.

m

ay c

ause

sof

twar

e an

d ha

rdwa

re m

alfu

nctio

n.

USE

USE

CA

UT

ION

US

E [S

LID

ER

/SW

ING

ER]

For

cont

inue

d pr

otec

tion

agai

nst

fire,

rep

lace

only

with

sam

e ty

pe a

nd r

atin

gof

fus

e.WA

RN

ING

FUSE

INS

IDE

RATI

NG:1

25V,

4ASI

ZE:5

.2 x

20m

m

GYR

O T

ECH

LAN

SON

IND

UST

RIE

SIN

C.

EN

TR

AN

CE

S

CO

LOR

BR

OW

NR

ED

BLA

CKW

HIT

E

GR

EEN

OR

ANG

E

OR

ANG

EO

RAN

GE

YE

LLO

WB

LUE

VIO

LET

GR

AY

7 61 6B9DC

12V

SY

MBO

L

H M0

M1

62 BA

OU

T +

OU

T -

SQ

1 2 3 4NO

.

5 6 7 8 9 10 11 12

POW

ER S

OURC

E (4

P)

OPER

ATOR

(6P)

EM

PTY

115V

AC

HO

TE

MPT

Y

115V

AC

CO

MM

ON

WH

ITE

BLA

CK

1 2 3 4

CO

LOR

NO

.

MO

TOR

V P

HAS

EE

NCO

DE

R 12

VDC

EN

COD

ER

A P

HA

SE

MO

TOR

U P

HAS

EE

NCO

DE

R G

NDE

NCO

DE

R B

PH

AS

E

OR

ANG

ER

ED

BR

OW

N

YE

LLO

W

CO

LOR

BLU

EB

LACK

1 2 3 4 5 6NO

.

DN 0008

KIT

PN 2

1104

71-0

2N

OTE

: LO

CK

WO

RKS

ON

LY IN

NIG

HT

& EX

IT M

ODE

S

BRO

WN

1431

97-0

5

VIO

LET

1016

49

9DC1

2V(B

ROW

N)

12

34

56

78

9

Electric Locks—Fail Safe

Page 14: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 14

Wire

Nut

1031

25R

ELAY

(DC

12V)

2292

40

MO

V10

1576

BRO

WN

1431

97-0

5VI

OLE

T 10

1649

(GR

N)

(OR

)

(OR

)

AC

24V

TRAN

SFO

RM

ERA

C11

5V

REC

TIFI

ER11

9929

-01

KIT

PN 2

1104

71-0

1N

OTE

: LO

CK

WO

RKS

ON

LY IN

NIG

HT

& EX

IT M

OD

ES

No.

MIC

RO

PR

OC

ES

SO

R C

ONT

RO

LLE

RG

YR

O T

EC

H -

24

890

1

HAND

Y TE

RMIN

AL (6

P)SE

NSOR

(12P

)

1.Pl

ease

adj

ust t

his

oper

ator

as

per i

nstru

ctio

n m

anua

l.2.

Turn

the

pow

er o

ff, b

efor

e op

enin

g th

e bo

x.3.

Don

't op

en th

is b

ox e

xcep

t for

repl

acin

g fu

se.

O

ther

wis

e, th

e w

arra

nty

will

be

term

inat

ed.

4.R

epai

r of t

his

unit

exce

pt b

y La

nson

Indu

strie

s, In

c.

may

cau

se s

oftw

are

and

hard

war

e m

alfu

nctio

n.

US

E

US

E

CA

UT

ION

US

E [S

LIDE

R/S

WIN

GE

R]

For

con

tinue

d pr

otec

tion

agai

nst f

ire,

repl

ace

only

with

sam

e ty

pe a

nd r

ating

of f

use.

WA

RN

ING

FUSE

IN

SID

ER

ATIN

G:1

25V,

4ASI

ZE:5

.2 x

20m

m

GYR

O T

ECH

LAN

SON

IND

UST

RIE

SIN

C.

EN

TR

AN

CE

S

CO

LOR

BRO

WN

RED

BLA

CK

WHI

TE

GRE

EN

ORA

NG

E

ORA

NG

EO

RAN

GE

YEL

LOW

BLU

EV

IOLE

TG

RAY

7 61 6B9DC1

2VS

YM

BO

L

H M0

M1

62 BA

OU

T +

OU

T -

SQ

1 2 3 4NO

.

5 6 7 8 9 10 11 12

POW

ER S

OURC

E (4

P)

OPER

ATOR

(6P)

EM

PT

Y

115V

AC

HO

TE

MP

TY

115V

AC

CO

MM

ON

WHI

TE

BLA

CK

1 2 3 4

CO

LOR

NO

.

MO

TO

R V

PH

AS

EE

NCO

DER

12V

DC

ENC

ODE

R A

PH

ASE

MO

TO

R U

PH

AS

EE

NCO

DER

GN

DE

NCO

DER

B P

HAS

E

OR

ANG

ER

ED

BR

OW

N

YE

LLO

W

CO

LOR

BLU

EB

LAC

K

1 2 3 4 5 6NO

.O

UT+

(V

IOLE

T)

OU

T-

(GR

AY)

7 (R

ED)

DN 0009

9DC

12V

(BR

OW

N)

(YEL

)

Wire

Nut

1031

25

Fail

Secu

re

Type

(BLK

/W

HT)

(BLK

/W

HT) EL

ECTR

IC L

OC

K / S

TRIK

E

ON

OPEN

>>>

CLO

SECL

OSED

LOCK

EDUN

LOCK

ED (O

N)

AC

TIV

ATE

SIG

NA

L

DO

OR

OU

TPU

TS

IGN

AL

time

delay

(0.2

5~1s

ec)

time

delay

(0.2

5~1s

ec)

CLOS

ED

LOCK

EDHa

ndy

Term

inal

: Au

x. O

utpu

t [0]

, tim

e de

lay

[0]~

[3]

Mod

e In

put :

One

Way

Tra

ffic

Mod

e or

Nig

ht M

ode

12

34

56

78

9

Electric Locks—Fail Secure

Page 15: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 15

Par

t No.

1110

431

BD

raw

ing

No.

PA

RT

NA

ME

:

MA

TE

RIA

L:

SP

EC

IFIC

ATI

ON

S:

SH

EE

T #

:1

OF

1

DA

TE:

SC

ALE

:D

RA

WN

BY

:A

PP

. BY

:

4-21

-03

JcMB

Non

e

TOLE

RA

NC

ES

(UN

LESS

NO

TED)

FR

AC

TIO

NA

L___

___±

1 64

X _

____

____

____

± .0

30X

X _

____

____

___±

.015

XX

X _

____

____

__±

.005

AN

GLE

___

____

____

± 1 2°

Dis

tribu

tor T

est H

arne

ss K

it

ITE

MQ

TYP

AR

T N

O.

DE

SC

RIP

TIO

N

1110

426

11

Doo

r Pos

ition

Har

ness

for M

agnu

m C

ontro

l11

1042

82

1Te

st H

arne

ss fo

r GT

1100

31

1110

427

Test

Har

ness

for G

T 30

0/40

0/50

0 A

nalo

g C

ontro

l

ER

N 8

94R

EVIS

IONS

DAT

E6-

11-0

3

AN

ALO

G C

ON

TRO

LTE

ST

HA

RN

ES

S F

OR

GT

300/

400/

500

LAB

EL:

TES

T H

AR

NE

SS

FO

R G

T 11

00LA

BE

L:

CO

NTR

OL

GT

300/

400/

500/

710

MA

GN

UM

D

OO

R P

OS

TIO

N T

ES

T H

AR

NE

SS

FO

R

LAB

EL:

12

34

8

76

5

Pan

ic S

witc

h B

ypas

s P

lug

1210

324

26

Mic

ropr

oces

sor S

witc

h Ju

mpe

r Plu

g1

511

9826

Mic

ropr

oces

sor T

est P

lug

14

1110

429

Inst

ruct

ion

Set

for D

istri

buto

r Tes

t Har

ness

Kit

18

1510

430

Mic

ropr

oces

sor J

umpe

r Plu

g1

711

5941

DN

0070

May

200

3P

art #

15-

1043

0T

est K

it M

anua

l

Har

ness

Kit

Dis

tribu

tor T

est

Inst

ruct

ion

Set

for

Tec

hnic

al A

ssis

tanc

e: 8

66-6

22-8

325

Fax

:

888

-679

-331

9P

hon

e: 8

77-6

22-2

694

Mus

keg

o, W

I 531

50P

.O.

Bo

x 90

6S

82

W18

717

Ge

min

i Driv

eN

AB

CO

EN

TR

AN

CE

S IN

C.

TES

T P

LUG

MIC

RO

PR

OC

ES

SO

RLA

BE

L:

JUM

PE

R P

LUG

MIC

RO

PR

OC

ES

SO

RLA

BE

L:

BY

PA

SS

PLU

GP

AN

IC S

WIT

CH

LAB

EL:

SW

ITC

H J

UM

PE

R P

LUG

MIC

RO

PR

OC

ES

SO

RLA

BE

L:

Trouble Shooting

Page 16: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 16

Troubleshooting

1. Acusensor does not seem to reach out far enougha) Move the area lever on the side of the Acusensor to a higher number.b) Increase the opening speed on the door with the Handy Terminal.c) If desired, replace Acusensor with Acumotion for greater detection range.

2. Acusensor is not seeing people accessing the door from the side.a) Turn on more of the area switches on the front of the Acusensor.b) Door is set to One Way Traffic mode and sensor is switched out. Set door to Auto mode.

3. When the doors are panicked open, the system does not shut down.a) Check the wiring of the power down switch in the fixed panel or bottom of header. (Full Open

Units.) Blue (BA) circuit must go open for system to shut down.b) Check the wiring of the breakout beam circuit. (Surface Applied Units.) Blue (BA) circuit must go

open for system to shut down.

4. Doors do not move when power is applied or Handy Terminal connected.a) Confirm the swing panel is closed completely.b) Confirm Blue (BA) circuit is not open. Zero VDC between Red and Blue on microprocessor har-

ness for correct operation. If 12VDC circuit is open.b) Check the power down magnet in the top rail of the swing panel is installed and aligned with the

magnetic power down switch in the bottom of the header.c) Confirm rocker is switch is set to ON not OFF.

5. The cover on the Acusensor will not snap on.a) Install thin washers to space the Acusensor off from the header and provide clearance for the cover.

6. Doors move very slowly when the Handy Terminal is connected. (Only happens after “Stroke Cycle” initiated.)

a) This is normal. It is “learning” the door stroke.b) After learning the stroke, the Handy Terminal will prompt you with options

7. The doors do not open completely.a) Look for obstructions in the track as well as inside the header. Check to make sure that the belt

clips are not hitting something.b) On Full Open units be sure that the interlock clips are adjusted properly.c) Check for any racking in the door.b) Check that the mode switch on the panel is not in “Reduced Opening” mode.c) Use the Handy Terminal and reinitialize the system.

8. I want to eliminate all outside switches and sensors and test the system with the Handy Terminal.a) Disconnect the 12-pin connector from inside the microprocessor and install the special connector

jumper tool p/n 115941 into its place.b) The system will consist of only the motor, operator and control box (Microprocessor). The Handy

Terminal will be the only means of operating the door.

Page 17: Automatic Entrance Systems - ABsupply.neto n l y a u t o d o r o p e r a t i o n red black red red o f night blue back side of switch shown. black white white red rocker switch extension

Sliders Electrical Manual

NABCOENTRANCES INC www.nabcoentrances.com - 17

Troubleshooting

9. I want to reset the system back to the factory settings.a) Plug in Hand Terminal and wait for the door to close.b) At “Swing/Slide/Stroke?” enter YES.c) At “Swing Door Y or N?” enter YES (even though you have a slide door).d) Door will try to initialize as a swing door and reset the settings.e) At “Swing/Slide/Stroke?” enter YES.f) At “Swing Door Y or N?” enter NO.g) The system will now initialize as a slide door to the factory settings.h) You must set the door stroke from the Handy Terminal from the prompts at this point.

10. Door does not run unless holding beam is interrupted.a) The holding beam connector (it has a red and white wire in it) in the main harness may be inadver-

tently plugged into one of the “Power Down” (blue wires) plugs. Any vacant “Power Down” plugs should have a blue jumper installed.

For technical assistance call: 866-622-8325or engineering at: 877-622-2694