Early History
• April 20, 1990: First presentation of a project frame at the RECFA Meeting at the Austrian Academy of Sciences by M. Regler (Co – author W. Mitaroff): Project for an international broad-field research and high-tech centre in Austria – AUSTRON
• The final specification of the project – a Spallation Source, was taken in April 1991 at a Meeting of the “Working Group on Science and Technology” of the “Central European Initiative” (CEI, former Hexagonale, former Pentagonale) in Bratislava
• October 1991: Workshop at CERN (hosted by C. Rubbia, organized by M. Regler): Quite detailed conceptual design report with a realistic cost estimate
Specifications
• Rapid Cycling Synchrotron 1.6 GeV / 25Hz / 100 kW with 4 kJ p/pulse on target; edge cooled target
• Medical facility with protons and carbon ions• Total cost: 225 MEUR (prices 1991, without med. fac.)• 1993/ 94: Feasibility Study (responsible: M. Regler,
Accelerator group hosted at CERN with project leader Ph. Bryant (other members paid by Austria), project leader for target and experiments M. Schuster)
• Ready December 1994: 200 kW (by increased injection energy, 70 > 130 MeV, Nr. of protons p/pulse: 3.2*1013
• Separate Medical Facility similar to the EULIMA design
Continuation 1995
• Continuation with a very small team at CERN and in Austria (much weekend support by Austrian staff members at CERN): 0.5 MW with a dual frequency magnet cycle (33/100 Hz); target still edge cooled (W5Re = Tungsten with 5% Rhenium)
• Foundation of the AUSTRON Society (Regler/Skalicky (rector of the Univ. of Technology Vienna))
• Feasibility Study of a Medical stand - alone Facility financed by the City of Wiener Neustadt and the province of Lower Austria until 1999
• Joint effort Med-AUSTRON – TERA – CERN resulting in the encouraging PIMMS study (Austria: 3 PhD students)
• Special Austrian contribution: Riesenradgantry
AUSTRON
• 1996 Hearing by the European Science Foundation• 1997 recommendation to the Austrian Government to
build AUSTRON after additional studies, mainly in the field of advanced and efficient instruments
• 1998: As a parallel result of this additional studies: Storage Ring to deliver 500kW at 10 Hz > 2*1014 protons p/pulse (pulse length ~ 1 000 ns)
• Peak neutron flux 4*1016/cm2s• 1999 – 2000: International contacts at the highest level, but• These activities were not really supported by the
Austrian neutron scattering community! (“Dormant project”)
Med - AUSTRON
• 2001 unanimous support by the Austrian Society of Radiooncology
• 5 MEUR for “fotec” in Wiener Neustadt (director E. Griesmayer) for additional studies (25% medicine and biology, project leader Dr. Auberger (Innsbruck), 75% for accelerator studies (chief consultant A. Wrulich, supported by H. Schoenauer and many others), economic evaluation and PR)
• Collaboration with the EU-ENLIGHT project, with CERN, “TERA”, GSI, Lyon, now also with SIEMENS
• Waiting for Federal Government !!!
Weltweite Protonen- und Ionentherapiezentren
Pionen 1.100
Ionen 4.290
Protonen 36.111
TOTAL 41.501
Stand Jänner 2004
Tiefendosisverhalten
Eindringtiefe
Energieabgabe
PlateauSingel Bragg Peak
(SBP)
Photonen
Querprofil
Protonen
Spread out Bragg Peak(SOBP)
Eindringverhalten in GewebeProtonen- und Ionentherapie.Photonentherapie
low und high -LET1MeV Protonen in H2O 1MeV/u C6+-Ionen in H2O
0,330
0,325
0,320
0,315
-5,0 0,0 5,0 -0,5 0,05,0
x (µm) x 10-3 x (µm) x 10-3
symbolisch
Aktives Scanning
DipolmagneteLetzte Schichte
Emin
Tumor
Erste Schichte
Emax
Prot 2 Felder Prot 4 Felder Phot 4 Felder Prot 6 Felder
Standard-Technik
Banding Magnetca. 120t
Strahl-richtung
Behandlungsraum imAufzug-Schienensystem Zugang für
Personal/Patient
RR-Gantry
Patienten-liege
Diss. Stefan Reimoser
Layout
10 m
© fotec 2004
2 ExperimentierräumeIonen-quellen
Qualitäts-kontrolle,Enddump
Strahldump
Linac
Synchrotron
2 horizontale Fixstrahlen Protonen-gantry
Ionen-gantry
Strahlgrößen-anpassung
4 medizinsche Behandlungsräume
Transferlinie
Protonen - Energie - Teilchenzahl
60 - 250 MeV/u11010
C-Ionen - Energie - Teilchenzahl
120 - 400 MeV/u4108
Der Standort Wiener Neustadt