au-shell cavity mode - mie calculations

8
1 Au-shell cavity mode - Mie calculations R core = 228 nm R total = 266 nm t Au = 38 nm medium = silica cavity mode 700 nm cavity mode 880 nm 880 nm = 340 THz

Upload: sanam

Post on 11-Jan-2016

29 views

Category:

Documents


0 download

DESCRIPTION

Au-shell cavity mode - Mie calculations. R core = 228 nm R total = 266 nm t Au = 38 nm medium = silica. cavity mode 700 nm. cavity mode 880 nm. 880 nm = 340 THz. 1. Finite Difference Time Domain method. k y. E x. Step 1: Excitation. Step 2: Relaxation. Step 3: Fourier Transform. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Au-shell cavity mode - Mie calculations

1

Au-shell cavity mode - Mie calculations

Rcore = 228 nm

Rtotal = 266 nm

tAu = 38 nmmedium = silica

cavity mode

700 nm

cavity mode

880 nm

880 nm = 340 THz

Page 2: Au-shell cavity mode - Mie calculations

2

Finite Difference Time Domain method

Step 1: Excitation

ky

Ex

Step 2: Relaxation Step 3: Fourier Transform

0 200 400 600 800 10000.000

0.005

0.010

0.015

0.020

0.025

0.030

Frequency (THz)

Am

plitu

de

Plane wave excitation on and off resonance stores some energy in particle

Particle oscillates, reemitting at its resonance frequency

Fast Fourier transform of the relaxation E(t) to generate frequency spectrum

Page 3: Au-shell cavity mode - Mie calculations

3

Snapshots - Au shell (R=266 nm, tAu = 38 nm) in silica box (1.5x1.5 μm2)

excitation off-resonanceat 150 THz (2 μm)

-2

-1

0

+1

+2

0 200 400 600 800 1000

FF

T o

f Ex

Frequency (THz)

0 20 40 60 80 100

x-co

mpo

nent

of E

-fie

ld (

a.u.

)

time (fs)

335 THz(895 nm)

Ex

Fast Fourier Transform

E-field monitor in center

p=1.3x1016 rad/s

=1.25 x1014 rad/s

d=9.54

Page 4: Au-shell cavity mode - Mie calculations

4

Snapshots - Au shell (R=266 nm, tAu = 38 nm) in silica box (1.5x1.5 μm2)

excitation off-resonanceat 150 THz (2 μm)

excitation on-resonanceat 335 THz (895 nm)

cavitymode!

Electric field intensity max= 6.5 at center

0

5

-2

-1

0

+1

+2

Ex

Page 5: Au-shell cavity mode - Mie calculations

Cavity parameters

• Quality factor Q=35

• The maximum field enhancement within the core amounts to a factor of 6.5

• The mode volume V=0.2 (/n)3 … 102-103 smaller than than that in micordisc/microtoroid WGM cavities

• A characteristic Purcell factor – assuming homogeneous field distribution in the cavity core and =895 nm

134

33

2

V

Q

nP

Page 6: Au-shell cavity mode - Mie calculations

Cavity optimization

544

33

2

V

Q

nP

A characteristic Purcell factor assuming homogeneous field distribution in the cavity core, =895 nm and Q=150:

Page 7: Au-shell cavity mode - Mie calculations

7

Cavity mode is tunable - T-matrix vs FDTD calculations

Penninkhof et al, JAP 103, 123105 (2008)

Page 8: Au-shell cavity mode - Mie calculations

8

Cavity mode is tunable by shape - oblate Au shell spheroid

aspect ratio =2.5

L / 410 THz

T / 240 THz