Attachment D Area Walk-by Checklists (AWCs) Engineering Report No. WF3-CS-12-00003 Attachment D Rev. 0 Page 1 of 210

Upload: vanhanh

Post on 24-Jul-2019

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Attachment D

Area Walk-by Checklists (AWCs)

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 1 of 210

Page 2: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-001

Location: Bldg. RAB Floor El. -35 Room, Area1 Safeguards B Room

SWEL Components: SWEL1-012, 036

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchor bolt on SISR-883 missing (1 of 4). See LB-01 in Attachment F.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• All anchorage is free of significantly degraded conditions.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 2 of 210

Page 3: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-001

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards B Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 3 of 210

Page 4: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-001

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards B Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Dinesh Patel Date: 10-02-2012

Natalie George 10-02-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 4 of 210

Page 5: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-001

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards B Room

SWEL Components: SWEL1-012, 036

Photographs

Note: Anchor bolt on SISR-883 missing (1 of 4)

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 5 of 210

Page 6: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-002

Location: Bldg. RAB Floor El. -35 Room, Area1 Safeguards Room A

SWEL Components: SWEL1-013, 051

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 6 of 210

Page 7: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-002

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room A

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Tubes lying around due to ongoing work; no seismic concern

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 7 of 210

Page 8: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-002

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room A

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Mild surface corrosion on base plate located by exit, no seismic concern; CR-WF3-2012-05285 and WR 287666 initiated to address corrosion

Evaluated by: Dinesh Patel Date: 10/3/12

Brian Pace 10/3/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 8 of 210

Page 9: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-002

Location: Bldg. RAB Floor El. -35 Room, Area Safeguards Room A

SWEL Components: SWEL1-013, 051

Photographs

Note: Mild surface corrosion on base plate located by exit

Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 9 of 210

Page 10: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-003

Location: Bldg. RAB Floor El. -35 Room, Area1 Room B17

SWEL Components: SWEL1-023, 030

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 10 of 210

Page 11: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-003

Location: Bldg. RAB Floor El. -35 Room, Area Room B17

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 11 of 210

Page 12: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-003

Location: Bldg. RAB Floor El. -35 Room, Area Room B17

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Bolt missing (1 of 6) near RAB sump pump SP EMTR213A AK, no seismic concern; WR 288319 initiated to address missing bolt

• One eye lift missing from cover near RAB sump pump SP EMTR213A AK; no seismic concern

Evaluated by: Natalie George Date: 10/8/12

Chu-Chieh Lin 10/8/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 12 of 210

Page 13: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-003

Location: Bldg. RAB Floor El. -35 Room, Area Room B17

SWEL Components: SWEL1-023, 030

Photographs

Note: Bolt missing (1 of 6) near RAB sump pump SP EMTR213A AK

Note: One eye lift missing from cover near RAB sump pump SP EMTR213A AK

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 13 of 210

Page 14: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-003

Location: Bldg. RAB Floor El. -35 Room, Area Room B17

SWEL Components: SWEL1-023, 030

Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 14 of 210

Page 15: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-004

Location: Bldg. RAB Floor El. -35 Room, Area1 Room B20

SWEL Components: SWEL1-056, 066

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 15 of 210

Page 16: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-004

Location: Bldg. RAB Floor El. -35 Room, Area Room B20

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 16 of 210

Page 17: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-004

Location: Bldg. RAB Floor El. -35 Room, Area Room B20

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Ceiling lights swing; no seismic concern as lights are well anchored and will not interact with other equipment

Evaluated by: Dinesh Patel Date: 10/2/12

Natalie George 10/2/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 17 of 210

Page 18: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-004

Location: Bldg. RAB Floor El. -35 Room, Area Room B20

SWEL Components: SWEL1-056, 066

Photographs

Note: Area

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 18 of 210

Page 19: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-005

Location: Bldg. RAB Floor El. -35 Room, Area1 Boric Acid Makeup Tank A Room

SWEL Components: SWEL1-016, 040, 089

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 19 of 210

Page 20: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-005

Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 20 of 210

Page 21: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-005

Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Housekeeping issues include loose rope from above and from a ladder; no seismic concern • Boric acid deposits on yoke bolt (bottom) of valve 131A, no seismic concern; CR-WF3-2011-

00024 and WR 224286 previously initiated for this condition • Active oil leak under Boric Acid Makeup Pump; towel dated 8-28-2012 to track amount of

leakage; no seismic concern • Bolts and steel corroded on supports on line connected to valve 113A, no seismic concern;

CR-WF3-2012-05296 and WR 287685 and 287687 initiated to address corrosion • Missing bolt (1 of 10) on B3424-NA, no seismic concern; CR-WF3-2012-05296 and WR

287689 initiated to address missing bolt

Evaluated by: Dinesh Patel Date: 10/3/12

Natalie George 10/3/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 21 of 210

Page 22: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-005

Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room

SWEL Components: SWEL1-016, 040, 089

Photographs

Note: Housekeeping issues include loose rope from above and from a ladder; trip hazard

Note: Boric acid deposits on yoke bolt (bottom) of valve 131A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 22 of 210

Page 23: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-005

Location: Bldg. RAB Floor El. -35 Room, Area Boric Acid Makeup Tank A Room

SWEL Components: SWEL1-016, 040, 089

Note: Active oil leak under Boric Acid Makeup Pump; towel dated 8-28-2012 to track amount of leakage

Note: Bolts and steel corroded on supports on line connected to valve 113A

Note: Missing bolt (1 of 10) on B3424-NA

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 23 of 210

Page 24: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-006

Location: Bldg. RAB Floor El. -35 Room, Area1 Shutdown Cooling Heat Exchanger A Room

SWEL Components: SWEL1-092

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 24 of 210

Page 25: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-006

Location: Bldg. RAB Floor El. -35 Room, Area Shutdown Cooling Heat Exchanger A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 25 of 210

Page 26: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-006

Location: Bldg. RAB Floor El. -35 Room, Area Shutdown Cooling Heat Exchanger A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• 2 hoses hanging from above to floor drain; no seismic concern

Evaluated by: Dinesh Patel Date: 10/3/12

Natalie George 10/3/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 26 of 210

Page 27: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-006

Location: Bldg. RAB Floor El. -35 Room, Area Shutdown Cooling Heat Exchanger A Room

SWEL Components: SWEL1-092

Photographs

Note: 2 hoses hanging from above to floor drain

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 27 of 210

Page 28: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-007

Location: Bldg. RAB Floor El. -35 Room, Area1 Emergency Feedwater Pump (Turbine Driven) Area

SWEL Components: SWEL1-010

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 28 of 210

Page 29: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-007

Location: Bldg. RAB Floor El. -35 Room, Area Emergency Feedwater Pump (Turbine Driven) Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• One contamination protection disposal bin not secured to others. See LB-02 in Attachment F.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 29 of 210

Page 30: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-007

Location: Bldg. RAB Floor El. -35 Room, Area Emergency Feedwater Pump (Turbine Driven) Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Dinesh Patel Date: 10/2/12

Natalie George 10/2/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 30 of 210

Page 31: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-007

Location: Bldg. RAB Floor El. -35 Room, Area Emergency Feedwater Pump (Turbine Driven) Area

SWEL Components: SWEL1- 010

Photographs

Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Note: Bin not secured to others

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 31 of 210

Page 32: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-008

Location: Bldg. CTB Floor El. -35 Room, Area1 Room 59A, Transformer Room

SWEL Components: SWEL1-008

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 32 of 210

Page 33: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-008

Location: Bldg. CTB Floor El. -35 Room, Area Room 59A, Transformer Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 33 of 210

Page 34: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-008

Location: Bldg. CTB Floor El. -35 Room, Area Room 59A, Transformer Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Mild corrosion on cooling tower fan housing, no seismic concern; CR-WF3-2012-04955 and WR 286025 initiated to address corrosion

• Mild corrosion on supports and structural steel, no seismic concern; CR-WF3-2012-04955 and WR 286027 initiated to address corrosion

• Spalled concrete above Fan 2-SB; no seismic concern • Exposed insulation on structural member near Fan 2-SB; no seismic concern

Evaluated by: Brian Pace Date: 10-15-2012

Dinesh Patel 10-15-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 34 of 210

Page 35: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-008

Location: Bldg. CTB Floor El. -35 Room, Area Room 59A, Transformer Room

SWEL Components: SWEL1- 008

Photographs

Note: Mild corrosion of structural steel. Note: Mild corrosion on cooling tower fan

housing.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 35 of 210

Page 36: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-008

Location: Bldg. CTB Floor El. -35 Room, Area Room 59A, Transformer Room

SWEL Components: SWEL1-008

Note: Spalled concrete; no seismic concern. Note: Exposed insulation. No seismic

concern.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 36 of 210

Page 37: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-009

Location: Bldg. CTB Floor El. -35 Room, Area1 B59A, Wet Cooling Tower B Area

SWEL Components: SWEL1-024

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchor bolt missing on pipe support. See LB-03 in Attachment F.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 37 of 210

Page 38: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-009

Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 38 of 210

Page 39: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-009

Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Conduit supports are corroded, no seismic concern; CR-WF3-2012-04960 and WR 286054 initiated to address corrosion

• Safety light cover and bulb broken, no seismic concern; CR-WF3-2012-04960 initiated to address light cover and bulb

• Diaphragm of valve CMUMVAAA407B is severely corroded; CR-WF3-2012-04960 and WR 104226 initiated to address corrosion

Evaluated by: Dinesh Patel Date: 10/1/12

Brian Pace 10/1/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 39 of 210

Page 40: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-009

Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area

SWEL Components: SWEL1-024

Photographs

Note: Corrosion on conduit supports Note: Missing one bolt from the plate, moderate corrosion on the box

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 40 of 210

Page 41: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-009

Location: Bldg. CTB Floor El. -35 Room, Area B59A, Wet Cooling Tower B Area

SWEL Components: SWEL1-024

Note: Safety light cover and bulb broken Note: Valve diaphragm is severely corroded

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 41 of 210

Page 42: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-010

Location: Bldg. CTA Floor El. -35 Room, Area1 WET COOLING TOWER A AREA

SWEL Components: SWEL1-060

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• All anchorage is free of potentially adverse seismic conditions.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No corrosion found on equipment anchorage.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 42 of 210

Page 43: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-010

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 43 of 210

Page 44: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-010

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Bolts on grounding cable supports on the wall under fan housing shows moderate to severe corrosion; no seismic concern; WR-289630 initiated for this condition

Evaluated by: Brian Pace Date: 10/5/12

Dinesh Patel 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 44 of 210

Page 45: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-010

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

SWEL Components: SWEL1-060

Photographs

Note: Bolts on grounding cable supports on the wall under fan housing shows moderate to severe corrosion

Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 45 of 210

Page 46: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-011

Location: Bldg. CTB Floor El. -35 Room, Area1 B60A, WET COOLING TOWER B AREA

SWEL Components: SWEL1-020

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

• Severe corrosion of tube steel supporting conduits • Conduit 30819D-SB corrosion • Corroded struts supporting large bore pipes (below and above) • Corroded angle steel member supporting overhead stairs

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 46 of 210

Page 47: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-011

Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Minor corrosion of steel plate, no seismic concern

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 47 of 210

Page 48: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-011

Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• CR-WF3-2012-05729 initiated to address corrosion conditions documented in this AWC.

Evaluated by: Dinesh Patel Date: 10-01-2012

Chu-Chieh Lin 10-01-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 48 of 210

Page 49: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-011

Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA

SWEL Components: SWEL1-020

Photographs

Note: Corrosion on the pipe Note: Corrosion on the pin

Note: Severe corrosion on the base plate and I beam

Note: Mild corrosion on the plate

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 49 of 210

Page 50: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-011

Location: Bldg. CTB Floor El. -35 Room, Area B60A, WET COOLING TOWER B AREA

SWEL Components: SWEL1-020

Note: Corrosion on the support stud Note: Severe Corrosion on the support of the

walkway

Note: Severe corrosion on the horizontal connector

Note: Conduit 30819D-SB corrosion

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 50 of 210

Page 51: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-013

Location: Bldg. CTA Floor El. -35 Room, Area1 WET COOLING TOWER A AREA

SWEL Components: SWEL1-015

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Bolts on nearby pipe support are mildly corroded (near SE wall); no seismic concern

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

• Condulet underneath junction box B3CCF284A-SA is mildly corroded; no seismic concern

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 51 of 210

Page 52: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-013

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Steel member overhead has mild surface corrosion on both ends; no seismic concern

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 52 of 210

Page 53: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-013

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Bolts on the blind flange and flange on south east wall has moderate corrosion, no seismic concern; CR-WF3-2012-05301 and WR 287691 initiated to address corrosion

• Electrical junction box B30613-NAB cover has three bolts missing (3 of 8), no seismic concern; CR-WF3-2012-05301 and WR 287695 initiated to address missing bolts

Evaluated by: Brian Pace Date: 10/5/12

Dinesh Patel 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 53 of 210

Page 54: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-013

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

SWEL Components: SWEL1-015

Photographs

Note: Bolts on nearby pipe support are mildly corroded

Note: Condulet underneath junction box B3CCF284A-SA is mildly corroded

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 54 of 210

Page 55: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-013

Location: Bldg. CTA Floor El. -35 Room, Area WET COOLING TOWER A AREA

SWEL Components: SWEL1-015

Note: Steel member overhead has mild corrosion on both ends

Note: Bolts on the blind flange and flange on south east wall has mild corrosion

Note: Electrical junction box B30618-NAB cover has three bolts missing (3 of 8)

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 55 of 210

Page 56: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-014

Location: Bldg. RAB Floor El. -35 Room, Area1 B59A, MCC AREA

SWEL Components: SWEL1-003

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Missing bolt on support near valve SPMVAAA328 • Bolts missing on pump base plate

o See LB-04 in Attachment F.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• SPMVAAA327 severely corroded • Severe corrosion on base plate • Severe corrosion on pipe support

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

• Conduit housing near valve SP MVAAA330 severely corroded

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 56 of 210

Page 57: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 014

Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 57 of 210

Page 58: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 014

Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• Moderate corrosion on valve SP MVAAA326 B

Y N U

Comments (Additional pages may be added as necessary)

• Mild corrosion on fan housing, no seismic concern • Mild corrosion on grate, pump base plate, base plate, etc., no seismic concern • Mild corrosion on supports throughout dry cooling tower area, no seismic concern • Insulation near valve SP MVAAA330 cracked; not a seismic concern • Moderate corrosion tornado/missile shielding structural steel • CR-WF3-2012-04956 was initiated to address all corrosion issues as well as the missing bolt

on the support near valve SPMVAAA328. • CR-WF3-2011-07679 and WR 255628 already addressed the moderate corrosion on valve

SP MVAAA326 B.

Evaluated by: Dinesh Patel Date: 10/01/2012

Chu-Chieh Lin 10/01/2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 58 of 210

Page 59: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 014

Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

SWEL Components: SWEL1- 003

Photographs

Note: Bolt missing on the supports near valve SPMVAAA328

Note: SPMVAAA327 severely corroded

Note: Moderate corrosion on valve SP MVAAA326 B

Note: Mild corrosion on grate, pump base plate, base plate, etc

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 59 of 210

Page 60: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 014

Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

SWEL Components: SWEL1- 003

Note: Severe corrosion on base plate Note: Bolts missing on pump base plate

Note: Severe corrosion on pipe support Note: Moderate corrosion tornado/missile

shielding structural steel

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 60 of 210

Page 61: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 6 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 014

Location: Bldg. RAB Floor El. -35 Room, Area B59A, MCC AREA

SWEL Components: SWEL1- 003

Note: Conduit housing near valve SP MVAAA330 severely corroded

Note: Insulation near valve SP MVAAA330 cracked

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 61 of 210

Page 62: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-015

Location: Bldg. RAB Floor El. +7 Room, Area1 HVAC EQUIPMENT ROOM

SWEL Components: SWEL1-039

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 62 of 210

Page 63: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-015

Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages, but falling bulbs would have no impact on equipment. No seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Housekeeping issues include clothes hanger on top of unit, coins and paper on the ground, and white caution tape on top of conduit; no seismic concern

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 63 of 210

Page 64: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-015

Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• CHW coil isolation valves CHWMVAAA231 and CHWMVAAA883 show leakage on top; no seismic concern

• SCH inlet isolation valves SCHMVAAA528 and SCHMVAAA553 show mild to moderate surface corrosion, no seismic concern; WR 287827 initiated to address corrosion

Evaluated by: Dinesh Patel Date: 10/2/12

Brian Pace 10/2/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 64 of 210

Page 65: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-015

Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM

SWEL Components: SWEL1-039

Photographs

Note: SCH inlet isolation valve SCHMVAAA553 shows mild to moderate surface corrosion

Note: SCH inlet isolation valve SCHMVAAA528 shows mild to moderate surface corrosion

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 65 of 210

Page 66: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-015

Location: Bldg. RAB Floor El. +7 Room, Area HVAC EQUIPMENT ROOM

SWEL Components: SWEL1-039

Note: Valve CHWMVAAA883 is leaking and shows signs of mild corrosion

Note: Valve CHWMVAAA231 is leaking and shows signs of mild corrosion

Note: Caution tape left behind piping Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 66 of 210

Page 67: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-016

Location: Bldg. RAB Floor El. +21 Room, Area1 Switchgear A Room

SWEL Components: SWEL1-006, 071, 082, 087

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 67 of 210

Page 68: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-016

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 68 of 210

Page 69: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-016

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• Conduit is rigidly supported to equipment. This is acceptable per drawing B288, S19-1.

Y N U

Comments (Additional pages may be added as necessary)

• Phone cord is a trip hazard; no seismic concern • Bent and missing weld on studs; no seismic concern • Missing clip on dummy breaker storage, bent door; no seismic concern • Base plate on support has eight bolt holes but only four bolts. However, this is acceptable

since all other similar supports have only four bolts; no seismic concern

Evaluated by: Natalie George Date: 10/4/12

Chu-Chieh Lin 10/4/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 69 of 210

Page 70: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-016

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear A Room

SWEL Components: SWEL1-006, 071, 082, 087

Photographs

Note: Phone cord is a trip hazard

Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Note: Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 70 of 210

Page 71: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-016

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear A Room

SWEL Components: SWEL1-006, 071, 082, 087

Note: Bent door on dummy breaker storage Note: Missing clip on dummy breaker storage

Note: Base plate on support has eight bolt holes but only four bolts

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 71 of 210

Page 72: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-017

Location: Bldg. RAB Floor El. +21 Room, Area1 Battery Room B

SWEL Components: SWEL1-070

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 72 of 210

Page 73: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-017

Location: Bldg. RAB Floor El. +21 Room, Area Battery Room B

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 73 of 210

Page 74: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-017

Location: Bldg. RAB Floor El. +21 Room, Area Battery Room B

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10/2/12

Dinesh Patel 10/2/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 74 of 210

Page 75: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-017

Location: Bldg. RAB Floor El. +21 Room, Area Battery Room B

SWEL Components: SWEL1-070

Photographs

Note: Battery racks and area Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 75 of 210

Page 76: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-018

Location: Bldg. RAB Floor El. +21 Room, Area1 Switchgear Room B

SWEL Components: SWEL1-002, 007, 068, 069, 097

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage is in good condition of equipment in the area.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No corrosion found on any anchorage in the area.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

• Conduit rigidly attached to equipment is acceptable per drawing no. B288 sh. 19-1

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 76 of 210

Page 77: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-018

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear Room B

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Lighting is in walkways, posing no seismic concern. • A temporary housing has been installed in the Switchgear B

Room. It has the potential to impact panels near it. The walls are bolted together, but there are no anchors bolting the enclosure to the floor. There is only a 7” clearance from LCP-62 and one side of the enclosure.

o This was resolved using CR-12-5172 and EC40448. See photos. Enclosure was braced at the top and bottom to structural steel members to ensure rigidity of the enclosure.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 77 of 210

Page 78: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-018

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear Room B

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-16-2012

Chu-Chieh Lin 10-16-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 78 of 210

Page 79: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-018

Location: Bldg. RAB Floor El. +21 Room, Area Switchgear Room B

SWEL Components: SWEL1-002, 007, 068, 069, 097

Photographs

Note: Temporary enclosure. Note: Example of temporary enclosure

possibly having an impact on cabinet LCP-62.

Note: Example of resolution to seismic concern.

Note: Example of resolution to seismic concern.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 79 of 210

Page 80: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-020

Location: Bldg. RAB Floor El. +21 Room, Area1 Component Cooling Pump B Room

SWEL Components: SWEL1-009

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage of nearby equipment is adequate.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No corrosion found on any equipment anchorage.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 80 of 210

Page 81: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-020

Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 81 of 210

Page 82: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-020

Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Minor surface corrosion on valve CHWMVAAA863, no seismic concern; WR 288420 initiated to address issue

Evaluated by: Brian Pace Date: 10-12-2012

Dinesh Patel 10-12-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 82 of 210

Page 83: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-020

Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room

SWEL Components: SWEL1-009

Photographs

Note: Minor surface corrosion on valve CHWMVAAA863.

Note: Additional equipment in area.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 83 of 210

Page 84: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-020

Location: Bldg. RAB Floor El. +21 Room, Area Component Cooling Pump B Room

SWEL Components: SWEL1-009

Note: Properly mounted equipment in area. Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 84 of 210

Page 85: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-021

Location: Bldg. RAB Floor El. +21 Room, Area1 Hallway near CCW Pump AB Room

SWEL Components: SWEL1-094

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 85 of 210

Page 86: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-021

Location: Bldg. RAB Floor El. +21 Room, Area Hallway near CCW Pump AB Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Lights are in walkway and falling bulbs would not impact equipment, no seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 86 of 210

Page 87: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-021

Location: Bldg. RAB Floor El. +21 Room, Area Hallway near CCW Pump AB Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10/4/12

Chu-Chieh Lin 10/4/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 87 of 210

Page 88: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-021

Location: Bldg. RAB Floor El. +21 Room, Area Hallway near CCW Pump AB Room

SWEL Components: SWEL1-094

Photographs

Note: Area around Nitrogen Accumulator #3 Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 88 of 210

Page 89: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-022

Location: Bldg. RAB Floor El. +21 Room, Area1 CCW Pump A Room

SWEL Components: SWEL1-065, SWEL2-010, 011

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 89 of 210

Page 90: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-022

Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 90 of 210

Page 91: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-022

Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• CHWMVAAA561 and CHWMVAAA563 are leaking; no seismic concern • Leakage and corrosion around pump, no seismic concern; WR 239478, CR-WF3-2011-04207,

WR 218753, and CR-WF3-2010-06818 in-progress to address issue • Broken insulation near valve CHWMVAAA559; no seismic concern

Evaluated by: Dinesh Patel Date: 10/4/12

Natalie George 10/4/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 91 of 210

Page 92: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-022

Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room

SWEL Components: SWEL1-065, SWEL2-011, 012

Photographs

Note: Valve CHWMVAAA561 is leaking

Note: Valve CHWMVAAA563 is leaking

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 92 of 210

Page 93: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-022

Location: Bldg. RAB Floor El. +21 Room, Area CCW Pump A Room

SWEL Components: SWEL1-065, SWEL2-011, 012

Note: Broken insulation near valve CHWMVAAA559

Note: Leakage and corrosion around CCW Pump

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 93 of 210

Page 94: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-023

Location: Bldg. RAB Floor El. +21 Room, Area1 CCW HX A Room

SWEL Components: SWEL1-090

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 94 of 210

Page 95: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-023

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Harnesses lying on ground near scaffolding; no seismic concern

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 95 of 210

Page 96: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-023

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Valves CHWMVAAA554 and CHWMVAAA556 are leaking and show mild corrosion; no seismic concern; WR 288402 initiated to address CHWMVAAA554 issues, WR288404 initiated to address CHWMVAAA556 issues

• Cover on drain below HX not secured; no seismic concern

Evaluated by: Natalie George Date: 10/4/12

Chu-Chieh Lin 10/4/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 96 of 210

Page 97: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-023

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room

SWEL Components: SWEL1-090

Photographs

Note: Harnesses lying on ground near scaffolding Note: Valve CHWMVAAA554 is leaking and shows mild corrosion

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 97 of 210

Page 98: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-023

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX A Room

SWEL Components: SWEL1-090

Note: Valve CHWMVAAA556 is leaking and shows mild corrosion

Note: Cover on drain below HX not secured

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 98 of 210

Page 99: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-024

Location: Bldg. RAB Floor El. +21 Room, Area1 CCW HX B Room

SWEL Components: SWEL1-014, 021

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage of all equipment is in good condition.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Mild corrosion found on pipe support associated with valve CHW-873. No seismic concern.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 99 of 210

Page 100: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-024

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Overhead fluorescent lights without cages are overhead. The fixture is well supported. Falling bulbs would have no impact on equipment in the area. There is no seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Minor housekeeping issues. A bucket and bottles located on the floor. No seismic concern.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 100 of 210

Page 101: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-024

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• A group of valves have mild surface corrosion on the bolts and yokes (CHWMVAAA872, CHWMVAAA873, CHWMVAAA874, CHWMVAAA875)

• CR-WF3-2012-05286 initiated to address corrosion CHWMVAAA872, CHWMVAAA873, CHWMVAAA874, CHWMVAAA875; CHWMVAAA872 covered by WR 287671, CHWMVAAA873 covered by WR 287669, CHWMVAAA874 covered by WR 287672, and CHWMVAAA875 covered by WR 287673

• CHWMVAAA876 has mild surface corrosion on the bolts and yokes • CR-WF3-2010-06306 and WR 216309 previously issued to address corrosion on

CHWMVAAA876 • These pose no seismic concern.

Evaluated by: Brian Pace Date: 10-12-2012

Dinesh Patel 10-12-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 101 of 210

Page 102: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-024

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room

SWEL Components: SWEL1-014, 021

Photographs

Note: Valve CHW-874 mild surface corrosion. Note: Valve CHW-872 with mild surface corrosion.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 102 of 210

Page 103: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-024

Location: Bldg. RAB Floor El. +21 Room, Area CCW HX B Room

SWEL Components: SWEL1-014, 021

Note: Mild corrosion on pipe support associated with valve CHW-873.

Note: Minor housekeeping issues.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 103 of 210

Page 104: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-025

Location: Bldg. RAB Floor El. +21 Room, Area1 Emergency Diesel Generator B Room

SWEL Components: SWEL1-043, 072, 081

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 104 of 210

Page 105: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-025

Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator B Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages, but falling bulbs will have not impact on equipment in the room. This is no seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Two unsecured disposal cans in front of panel but would have no adverse effect on the panel if it was impacted by cans.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 105 of 210

Page 106: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-025

Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator B Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• Conduits rigidly attached to equipment are acceptable per drawing no. B288 sh. 19-1

Y N U

Comments (Additional pages may be added as necessary)

• Electrical junction box 2 (conduit 222-7909002-21) has two missing bolts and one loose bolt (out of 14 total); no seismic concern

• Valves EGFMVAAA126B and EGFMVAAA127B near support EGRR-3019 show mild corrosion; no seismic concern

Evaluated by: Dinesh Patel Date: 10/2/12

Brian Pace 10/2/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 106 of 210

Page 107: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-025

Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator B Room

SWEL Components: SWEL1-043, 072, 081

Photographs

Note: Electrical junction box 2 has two missing bolts and one loose bolt

Note: Mild corrosion on valves EGFMVAAA126B and EGFMVAAA127B

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 107 of 210

Page 108: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-028

Location: Bldg. RB Floor El. -35 Room, Area1 RB -35 Central Area

SWEL Components: SWEL1-025, 052, 053, 054, 055, 057, 058

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 108 of 210

Page 109: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-028

Location: Bldg. RB Floor El. -35 Room, Area RB -35 Central Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages but will not affect equipment if bulbs fall. Fixture is rigid.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 109 of 210

Page 110: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-028

Location: Bldg. RB Floor El. -35 Room, Area RB -35 Central Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Clip on SI MVAAA225A not secure; no seismic concern • Hoses on ground due to work in progress; no seismic concern • Leak on BD MPMP0004. WO#319512 addresses this leak. No seismic concern. • One clip on insulation of pipe associated with valve SI MVAAA138-B is broken near the elbow.

No seismic concern.

Evaluated by: Dinesh Patel Date: 10-15-2012

Brian Pace 10-15-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 110 of 210

Page 111: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-028

Location: Bldg. RB Floor El. -35 Room, Area RB -35 Central Area

SWEL Components: SWEL1-025, 052, 053, 054, 055, 057, 058

Photographs

Note: Leak addressed by WO#319512 Note: Clip on SI MVAAA225A not secure

Note: Hoses on ground due to work in progress Note: Broken clip on insulation around pipe

associated with valve SI MVAAA138-B.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 111 of 210

Page 112: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-029

Location: Bldg. RB Floor El. -35 Room, Area1 Diesel Oil Storage Tank A Room

SWEL Components: SWEL1-011, 093

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage of equipment is free of adverse conditions.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Corrosion and minor oil leaks found on valves near the tank (EGFMVAAA104-A and EGFMVAAA1061 and EGFMVAAA105A).

• Corrosion found on sump pumps SP EMTR213B-7B and SP EMTR213A-7B in the area.

• The level gauge attached to the tank had minor surface corrosion.

• Two pipe supports above this equipment had corroded bolts. • No seismic concerns due to these issues. • CR-WF3-2012-05284 and WR-287663 initiated to address

these conditions.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 112 of 210

Page 113: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-029

Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 113 of 210

Page 114: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-029

Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10/5/12

Dinesh Patel 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 114 of 210

Page 115: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-029

Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room

SWEL Components: SWEL1-011, 093

Photographs

Note: Valve EGFMVAAA104-A surface corrosion.

Note: Valve EGFMVAAA1061 with mild surface corrosion.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 115 of 210

Page 116: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-029

Location: Bldg. RB Floor El. -35 Room, Area Diesel Oil Storage Tank A Room

SWEL Components: SWEL1-011, 093

Note: Sump pumps SP EMTR213A-7B and SP EMTR213B-7B near tank have mild surface corrosion.

Note: Pipe support with corroded bolts.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 116 of 210

Page 117: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-030

Location: Bldg. RB Floor El. -4 Room, Area1 B100 / 10A - M

SWEL Components: SWEL1-017, 022, 033, 076

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Bolt displays mild corrosion; no seismic concern

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 117 of 210

Page 118: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-030

Location: Bldg. RB Floor El. -4 Room, Area B100 / 10A - M

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Barrels near column 10A, line N are not properly secured. See LB-05 in Attachment F.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 118 of 210

Page 119: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-030

Location: Bldg. RB Floor El. -4 Room, Area B100 / 10A - M

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Damage to jacketing near valve BD MVAAA107-A, potential insulation damage; no seismic concern

• Mild corrosion on valves throughout; no seismic concern

Evaluated by: Natalie George Date: 10/5/12

Chu-Chieh Lin 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 119 of 210

Page 120: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-030

Location: Bldg. RB Floor El. -4 Room, Area B100 / 10A - M

SWEL Components: SWEL1-017, 022, 033, 076

Photographs

Note: Bolts display mild corrosion Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 120 of 210

Page 121: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-030

Location: Bldg. RB Floor El. -4 Room, Area B100 / 10A - M

SWEL Components: SWEL1-017, 022, 033, 076

Note: Barrels near column 10A, line N are not properly secured

Note: Damage to jacketing near valve BD MVAAA107-A; potential insulation damage

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 121 of 210

Page 122: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-032

Location: Bldg. RAB Floor El. +46 Room, Area1 Control Room

SWEL Components: SWEL-084, 085, 086

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 122 of 210

Page 123: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-032

Location: Bldg. RAB Floor El. +46 Room, Area Control Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Book case and trash can next to IC ECP08 should be moved or bolted (anchored), book case adjacent to IC ECP22 should be moved or bolted, trash can in front of IC ECP11B should be moved

o After reevaluation of these components, it was determined that all loose items in the control room are anchored. Calculation ECC-095-005 was issued for the loose items in the control room after IPEEE identified these same issues.

o The trash cans were also determined to be made of material that could not damage the surrounding cabinets.

• Table and trash can next to IC ECP20 should be moved o This is not a seismic concern because it is next to

Non-Safety Related equipment, but must be moved for personnel safety.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 123 of 210

Page 124: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-032

Location: Bldg. RAB Floor El. +46 Room, Area Control Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Natalie George Date: 10/8/12

Chu-Chieh Lin 10/8/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 124 of 210

Page 125: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-032

Location: Bldg. RAB Floor El. +46 Room, Area Control Room

SWEL Components: SWEL-084, 085, 086

Photographs

Note: Book case and trash can next to IC ECP08 should be moved or bolted (anchored) (Determined to not be an issue)

Note: Book case adjacent to IC ECP22 should be moved or bolted (Determined to be anchored)

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 125 of 210

Page 126: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-032

Location: Bldg. RAB Floor El. +46 Room, Area Control Room

SWEL Components: SWEL-084, 085, 086

Note: Table and trash can next to IC ECP20 should be moved

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 126 of 210

Page 127: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-035

Location: Bldg. RAB Floor El. +46 Room, Area1 Emergency Diesel Oil Feed Tank A Room

SWEL Components: SWEL1-074

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• All anchorage of nearby equipment, including the Diesel Oil Feed Tank A, is in good condition.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No degraded conditions found on anchors.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 127 of 210

Page 128: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-035

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• A wrench located on top of a structural steel member could fall and damage valve nearby.

• The wrench was removed and brought to the tool room, solving the potentially adverse seismic condition.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 128 of 210

Page 129: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-035

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Oil leak from diesel tank flange. Currently being resolved with WR#232292 and CR#11-1860. No seismic concern.

• One drain valves had a slight leak on it as well. No seismic concern.

Evaluated by: Brian Pace Date: 10-08-2012

Dinesh Patel 10-08-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 129 of 210

Page 130: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-035

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room

SWEL Components: SWEL1-074

Photographs

Note: Wrench with potential adverse seismic condition. Note that the wrench was removed and brought to the tool room, removing the condition.

Note: Leak on the diesel oil feed tank.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 130 of 210

Page 131: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-035

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Diesel Oil Feed Tank A Room

SWEL Components: SWEL1-074

Note: Leak on valve in room. Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 131 of 210

Page 132: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-036

Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

SWEL Components: SWEL1-032, 063

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage of equipment appears to be in good condition

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Valve CHWMVAAA201 has surface corrosion on yoke plate and bolts, CR-WF3-2012-05627 and WR 288441 initiated to address corrosion; not a seismic concern

• Bolt and pipe clamp on pipe support near fan E-28 has surface corrosion; not a seismic concern

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 132 of 210

Page 133: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-036

Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Overhead lighting is not above any equipment

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 133 of 210

Page 134: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-036

Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Crushed insulation on pipe on top of scaffolding by fan E-28; not a seismic concern

Evaluated by: Dinesh Patel Date: 10-08-2012

Brian Pace 10-08-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 134 of 210

Page 135: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-036

Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

SWEL Components: SWEL1-032, 063

Photographs

Note: Surface corrosion on valve CHWMVAAA201

Note: Surface corrosion on valve CHWMVAAA201 from underneath

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 135 of 210

Page 136: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-036

Location: Bldg. RAB Floor El. +46 Room, Area E28 Fan Area

SWEL Components: SWEL1-032, 063

Note: Surface corrosion on pipe clamp on pipe support near fan E-28

Note: Crushed insulation on pipe lying on scaffolding near fan E-28

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 136 of 210

Page 137: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-037

Location: Bldg. RAB Floor El. +46 Room, Area1 NORTHWEST RAB +46 AREA

SWEL Components: SWEL1-031, 041, 049, 050, 067, 088

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 137 of 210

Page 138: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-037

Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

• Chain from crane should be re-positioned so it will not interaction w/ panel or piping; see LB-06 in Attachment F.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 138 of 210

Page 139: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-037

Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• Severe corrosion on valves CHWMVAAA121A and CHWMVAAA788A

o CR-WF3-2012-06472 and WO 196829 initiated for CHWMVAAA121A.

o CR-WF3-2012-05372 and WR287812 were initiated for CHWMVAAA788A.

• Severe corrosion and leakage on valves CHWMVAAA127B, CHWMVAAA436, and CHWMVAAA881

o CR-WF3-2012-05372 and WR 287813 initiated for CHWMVAAA127B.

o CR-WF3-2012-05089 and WR 286898 and WR 286900 already written for CHWMVAAA436 and CHWMVAAA887.

Y N U

Comments (Additional pages may be added as necessary)

• Mild corrosion and leakage on pump CHWMPMP0001B, no seismic concern; CR-WF3-2010-05497 and WR 212221 in-progress to address issues

• Loose screws inside of pump CHWMPMP0001B, no seismic concern; WR 287826 initiated to address issue

• Mild corrosion and leakage on valves CHWMVAAA248, CHWMVAAA550, CHWMVAAA1341B, and CHWMVAAA1343B, no seismic concern

o WR 287824 initiated for CHWMVAAA248, CR-WF3-2012-05732 and WR 287815 and WR 287816 written for CHWMVAAA1341B and CHWMVAAA1343B, WR 44875 in-progress for CHWMVAAA550

Evaluated by: Natalie George Date: 10/15/12

Chu-Chieh Lin 10/15/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 139 of 210

Page 140: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-037

Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA

SWEL Components: SWEL1-031, 041, 049, 050, 067, 088

Photographs

Note: Severe corrosion on valve CHWMVAAA121A

Note: Severe corrosion on valve CHWMVAAA788A

Note: Severe corrosion and leakage on valve CHWMVAAA127B

Note: Mild corrosion and leakage on pump CHWMPMP0001B

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 140 of 210

Page 141: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-037

Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA

SWEL Components: SWEL1-031, 041, 049, 050, 067, 088

Note: Loose screws inside of pump CHWMPMP0001B

Note: Mild corrosion and leakage on valve CHWMVAAA1341B

Note: Mild corrosion and leakage on valve CHWMVAAA1343B

Note: Mild corrosion and leakage on valve CHWMVAAA248

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 141 of 210

Page 142: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 6 of 6 Status: Y N U

Area Walk-By Checklist (AWC) AWC-037

Location: Bldg. RAB Floor El. +46 Room, Area NORTHWEST RAB +46 AREA

SWEL Components: SWEL1-031, 041, 049, 050, 067, 088

Note: Mild corrosion and leakage on valve CHWMVAAA550

Note: Severe corrosion and leakage on valve CHWMVAAA436

Note: Severe corrosion and leakage on valve CHWMVAAA881

Note: Chain from crane should be re-positioned so it will not interaction w/ panel or piping

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 142 of 210

Page 143: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-038

Location: Bldg. RAB Floor El. +46 Room, Area1 Emergency Vent Air Clean Up Units Area

SWEL Components: SWEL1-029, 061, 062, 064

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 143 of 210

Page 144: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 038

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Vent Air Clean Up Units Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 144 of 210

Page 145: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 038

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Vent Air Clean Up Units Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• Block wall in area acceptable per drawing no. G765 sh. 2, calculation no. Civil Seismic Block Walls, and FSAR Section 3.8.4.8

Y N U

Comments (Additional pages may be added as necessary)

• Damage to insulation on HVC-215A and AH-12B; no seismic concern

Evaluated by: Natalie George Date: 10/9/12

Chu-Chieh Lin 10/9/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 145 of 210

Page 146: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC- 038

Location: Bldg. RAB Floor El. +46 Room, Area Emergency Vent Air Clean Up Units Area

SWEL Components: SWEL1-029, 061, 062, 064

Photographs

Note: Damage to insulation on HVC-215A Note: Damage to insulation on AH-12B

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 146 of 210

Page 147: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-039

Location: Bldg. RAB Floor El. +46 Room, Area1 AH-25B Room

SWEL Components: SWEL1-042

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• All components in the vicinity of CHWMVAAA900 are well anchored.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Mild surface corrosion on bolt on AH-25B and steel along bottom of air handler, but this poses no seismic impact; WR 288417 initiated to address corrosion

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 147 of 210

Page 148: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-039

Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Overhead lighting has no covers, but falling bulbs would have no impact on equipment underneath. Fixtures are well supported.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

• Unsecured tool box is in designated storage area.

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 148 of 210

Page 149: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-039

Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• There is a piece of steel tied with a rope to base plate at two locations. Once of them is near a valve. It was determined that the steel piece in the vicinity of this valve could not make impact with the valve during a seismic event. Therefore, this is no seismic concern.

• Three ladders in the area are all well secured.

Y N U

Comments (Additional pages may be added as necessary)

• Loose insulation near AH-25B; no seismic concern.

Evaluated by: Dinesh Patel Date: 10-09-2012

Brian Pace 10-09-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 149 of 210

Page 150: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-039

Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room

SWEL Components: SWEL1-042

Photographs

Note: Hanging steel determined not to have an impact on the nearby valves.

Note: Corrosion on bolt and surrounding steel at the bottom of AH-25B.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 150 of 210

Page 151: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-039

Location: Bldg. RAB Floor El. +46 Room, Area AH-25B Room

SWEL Components: SWEL1-042

Note: Insulation is loose near AH-25B. Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 151 of 210

Page 152: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-040

Location: Bldg. RAB Floor El. +91 Room, Area1 CCW Surge Tank Area

SWEL Components: SWEL1-073, 091

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage of equipment is in good condition.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Slight surface corrosion on two base plates for pipe supports on LS-CC-7011BS; WR 288395 initiated to address corrosion

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 152 of 210

Page 153: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-040

Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 153 of 210

Page 154: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-040

Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-08-2012

Dinesh Patel 10-08-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 154 of 210

Page 155: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-040

Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area

SWEL Components: SWEL1-073, 091

Photographs

Note: Turbine Cooling Water Surge Tank well anchored from walk-by observations.

Note: All additional valves and level switches well supported and cause no spatial interaction concerns.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 155 of 210

Page 156: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-040

Location: Bldg. RAB Floor El. +91 Room, Area CCW Surge Tank Area

SWEL Components: SWEL1-073, 091

Note: Surface corrosion on base plate (one of two shown).

Note:

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 156 of 210

Page 157: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-041

Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

SWEL Components: SWEL1-078

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• Degradation of concrete pad near embedded plates to which legs of tank NG-MACC-005 are welded, adverse seismic concern; identified in CR-WF3-2012-05278 and WR 287650

• Cracks in concrete near embedded plates to which legs of tank NG-MACC-006 are welded, adverse seismic concern; identified in CR-WF3-2012-05278 and WR 287650

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

• Severe corrosion on support for conduit lines 32095G-NB and 32095F-NB, adverse seismic concern; CR-WF3-2012-05203 and WR 287462 initiated to address corrosion

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 157 of 210

Page 158: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-041

Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 158 of 210

Page 159: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-041

Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Mild corrosion throughout area, no seismic concern; CR-WF3-2012-5203, CR-WF3-2012-05278, WR 287643, WR 287645, WR 287646, and WR 287462 initiated to address corrosion

• Water pooling in recessed embedded plates, no seismic concern; CR-WF3-2012-05278 and WR’s 287643, 287645, 287646, and 287650 initiated to address issue

Evaluated by: Natalie George Date: 10/5/12

Chu-Chieh Lin 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 159 of 210

Page 160: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-041

Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

SWEL Components: SWEL1-078

Photographs

Note: Degradation of concrete pad near embedded plates to which legs of tank NG-MACC-005 are welded

Note: Cracks in concrete near embedded plates to which legs of tank NG-MACC-006 are welded

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 160 of 210

Page 161: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-041

Location: Bldg. RB Floor El. +46 Room, Area AH-32, 34, 35 ROOM (ON ROOF)

SWEL Components: SWEL1-078

Note: Severe corrosion on support for conduit lines 32095G-NB and 32095F-NB

Note: Water pooling in recessed embedded plates

Note: Mild corrosion on MS MVAAA124 AA Note: Mild corrosion on MS MVAAA124 AB

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 161 of 210

Page 162: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-042

Location: Bldg. RB Floor El. +46 Room, Area West Wing Area

SWEL Components: SWEL1-001, 034, 044, 045, 046

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 162 of 210

Page 163: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-042

Location: Bldg. RB Floor El. +46 Room, Area West Wing Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 163 of 210

Page 164: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-042

Location: Bldg. RB Floor El. +46 Room, Area West Wing Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Mild corrosion throughout, on supports, valves, etc., no seismic concern; CR-WF3-2012-05278 and WR’s 287643, 287645, 287646, and 287650 initiated to address corrosion

• Water pooling at base of pipe support, recessed embedded plate; no seismic concern

Evaluated by: Natalie George Date: 10/5/12

Chu-Chieh Lin 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 164 of 210

Page 165: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-042

Location: Bldg. RB Floor El. +46 Room, Area West Wing Area

SWEL Components: SWEL1-001, 034, 044, 045, 046

Photographs

Note: Mild corrosion on supports throughout area Note: Mild corrosion on valves throughout area

Note: Mild corrosion on supports throughout area Note: Mild corrosion on valves throughout area

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 165 of 210

Page 166: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 5 of 5 Status: Y N U

Area Walk-By Checklist (AWC) AWC-042

Location: Bldg. RB Floor El. +46 Room, Area West Wing Area

SWEL Components: SWEL1-001, 034, 044, 045, 046

Note: Mild corrosion on valves throughout area Note: Water pooling at base of pipe support

Note: Mild corrosion on valves throughout area and dent on the pipe

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 166 of 210

Page 167: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-043

Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area

SWEL Components: SWEL1-035

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 167 of 210

Page 168: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-043

Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 168 of 210

Page 169: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-043

Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Corrosion throughout area; CR-WF3-2012-05198 initiated to address corrosion • Valve MS MVAAA124-B62 is leaking, previously documented and funnel in place

Evaluated by: Natalie George Date: 10/5/12

Chu-Chieh Lin 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 169 of 210

Page 170: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-043

Location: Bldg. RB Floor El. +46 Room, Area Southeast Wing Area

SWEL Components: SWEL1-035

Photographs

Note: Corrosion throughout area Note: Valve MS MVAAA124-B62 is leaking,

previously documented and funnel in place

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 170 of 210

Page 171: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-044

Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area

SWEL Components: SWEL1-027, 028

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 171 of 210

Page 172: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-044

Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 172 of 210

Page 173: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-044

Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Mild corrosion throughout area, no seismic concern; CR-WF3-2012-05207, CR-WF3-2012-05278, WR 287493, WR 287643, WR 287645, WR 287646,

and WR 287650 initiated to address issue • Water pooling in structural support, no seismic concern; CR-WF3-2012-05207,

CR-WF3-2012-05278, WR 287493, WR 287643, WR 287645, WR 287646, and WR 287650 initiated to address issue •

Evaluated by: Natalie George Date: 10/5/12

Chu-Chieh Lin 10/5/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 173 of 210

Page 174: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-044

Location: Bldg. RB Floor El. +46 Room, Area Northeast Wing Area

SWEL Components: SWEL1-027, 028

Photographs

Note: Corrosion throughout area Note: Water pooling in structural support

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 174 of 210

Page 175: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-045

Location: Bldg. RAB Floor El. +21 Room, Area1 Emergency Diesel Generator A Room

SWEL Components: SWEL1-095, 096

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 175 of 210

Page 176: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-045

Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 176 of 210

Page 177: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-045

Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Cover not secure on north side of emergency diesel generator; no seismic concern • Housekeeping issue; no seismic concern

o Gloves left in area

Evaluated by: Natalie George Date: 10/8/12

Chu-Chieh Lin 10/8/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 177 of 210

Page 178: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-045

Location: Bldg. RAB Floor El. +21 Room, Area Emergency Diesel Generator A Room

SWEL Components: SWEL1-095, 096

Photographs

Note: Cover not secure on north side of emergency diesel generator

Note: Gloves left in area

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 178 of 210

Page 179: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-046

Location: Bldg. FHB Floor El. +1 Room, Area1 Multiplexer Enclosure West Side

SWEL Components: SWEL2-017, 018, 019

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 179 of 210

Page 180: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-046

Location: Bldg. FHB Floor El. +1 Room, Area Multiplexer Enclosure West Side

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

• Pipe from CCW tank should have been previously analyzed for seismic event; no seismic concern

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 180 of 210

Page 181: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-046

Location: Bldg. FHB Floor El. +1 Room, Area Multiplexer Enclosure West Side

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Several valves are leaking oil (CC MVAAA617, CC MVAAA618, and CC MVAAA622), no seismic concern; WR 288397 initiated for CC MVAAA617, WR288398 initiated for CC MVAAA618, and WR 288399 initiated for CC MVAAA622

Evaluated by: Natalie George Date: 10/10/12

Chu-Chieh Lin 10/10/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 181 of 210

Page 182: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-046

Location: Bldg. FHB Floor El. +1 Room, Area Multiplexer Enclosure West Side

SWEL Components: SWEL2-017, 018, 019

Photographs

Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Note: Example of valve leaking oil

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 182 of 210

Page 183: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-047

Location: Bldg. FHB Floor El. +1 Room, Area1 Fuel Pool Heat Exchanger Room

SWEL Components: SWEL2-020

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Conduits and pipe supports well anchored

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No corrosion found

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 183 of 210

Page 184: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-047

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Heat Exchanger Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 184 of 210

Page 185: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-047

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Heat Exchanger Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012

Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 185 of 210

Page 186: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-047

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Heat Exchanger Room

SWEL Components: SWEL2-020

Photographs

Note: Example of pipe support in good condition.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 186 of 210

Page 187: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-048

Location: Bldg. FHB Floor El. +1 Room, Area1 Fuel Pool Pump A Room

SWEL Components: SWEL2-012, 015

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 187 of 210

Page 188: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-048

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump A Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 188 of 210

Page 189: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-048

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump A Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Natalie George Date: 10/10/12

Chu-Chieh Lin 10/10/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 189 of 210

Page 190: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-048

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump A Room

SWEL Components: SWEL2-012, 015

Photographs

Note: Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 190 of 210

Page 191: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-049

Location: Bldg. FHB Floor El. +1 Room, Area1 Fuel Pool Pump B Room

SWEL Components: SWEL2-013, 016

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 191 of 210

Page 192: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-049

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump B Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 192 of 210

Page 193: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-049

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump B Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Natalie George Date: 10/12/12

Chu-Chieh Lin 10/12/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 193 of 210

Page 194: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-049

Location: Bldg. FHB Floor El. +1 Room, Area Fuel Pool Pump B Room

SWEL Components: SWEL2-013, 016

Photographs

Note: Fuel Pool Pump B Room

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 194 of 210

Page 195: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-050

Location: Bldg. FHB Floor El. -35 Room, Area1 Refuel Canal Drain Pump Area

SWEL Components: SWEL2-014, 022, 023, 024, 025, 026

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• All anchorage in area is in good condition

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No degraded conditions were found on any anchorage

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 195 of 210

Page 196: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-050

Location: Bldg. FHB Floor El. -35 Room, Area Refuel Canal Drain Pump Area

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Overhead lights with no covers present. No seismically sensitive equipment in vicinity; no seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 196 of 210

Page 197: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-050

Location: Bldg. FHB Floor El. -35 Room, Area Refuel Canal Drain Pump Area

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012

Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 197 of 210

Page 198: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-050

Location: Bldg. FHB Floor El. -35 Room, Area Refuel Canal Drain Pump Area

SWEL Components: SWEL2-014, 022, 023, 024, 025, 026

Photographs

Note: All overhead equipment is properly secured.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 198 of 210

Page 199: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-051

Location: Bldg. FHB Floor El. -35 Room, Area1 Back-Up Fuel Pool Heat Exchanger Room

SWEL Components: SWEL2-021

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Conduits and pipe supports well anchored

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No corrosion or any other degraded condition were found on anchorage

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 199 of 210

Page 200: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-051

Location: Bldg. FHB Floor El. -35 Room, Area Back-Up Fuel Pool Heat Exchanger Room

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 200 of 210

Page 201: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-051

Location: Bldg. FHB Floor El. -35 Room, Area Back-Up Fuel Pool Heat Exchanger Room

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012

Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 201 of 210

Page 202: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-051

Location: Bldg. FHB Floor El. -35 Room, Area Back-Up Fuel Pool Heat Exchanger Room

SWEL Components: SWEL2-021

Photographs

Note: Sample of area walk-by Note: Sample of area walk-by

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 202 of 210

Page 203: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-052

Location: Bldg. RAB Floor El. +35 Room, Area1 Relay Room B

SWEL Components: SWEL2-004

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

• Anchorage in area is in good condition.

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

• No degraded conditions were observed.

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 203 of 210

Page 204: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-052

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 204 of 210

Page 205: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-052

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

• Possible surface cracks can be seen in the floor. Most have been filled. These cracks do not pose seismic concerns.

• Blocks walls located around the room are acceptable per drawing no. G765 sh. 2, calculation no. Civil Seismic Block Walls, and FSAR Section 3.8.4.8

Y N U

Comments (Additional pages may be added as necessary)

Evaluated by: Brian Pace Date: 10-10-2012

Dinesh Patel 10-10-2012

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 205 of 210

Page 206: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-052

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

SWEL Components: SWEL2-004

Photographs

Note: Reinforced block wall Note: Possible surface cracks. Most have been filled

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 206 of 210

Page 207: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 1 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-053

Location: Bldg. RAB Floor El. +35 Room, Area1 RAB +35

SWEL Components: SWEL1-083, SWEL2-005

Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Y N U N/A

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?

Y N U N/A

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 207 of 210

Page 208: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 2 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-053

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

• Fluorescent lights do not have cages. Falling bulbs will not damage equipment and is not a seismic concern.

Y N U N/A

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?

Y N U N/A

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?

Y N U N/A

7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Y N U N/A

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 208 of 210

Page 209: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 3 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-053

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?

Y N U

Comments (Additional pages may be added as necessary)

• Operations appendix R supplies locker not anchored; will not interact with equipment if it falls. Referred to Permit # RAB+35-10-488

• Block wall near equipment acceptable per drawing no. G765 sh. 2, calculation no. Civil Seismic Block Walls, and FSAR Section 3.8.4.8

Evaluated by: Natalie George Date: 10/15/12

Chu-Chieh Lin 10/15/12

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 209 of 210

Page 210: Attachment D Area Walk-by Checklists (AWCs) · RAB 1Floor El. -35 Room, Area. Safeguards B Room . SWEL Components: SWEL1-012, 036 ... raceways and HVAC ducting appear to be free of

Sheet 4 of 4 Status: Y N U

Area Walk-By Checklist (AWC) AWC-053

Location: Bldg. RAB Floor El. +35 Room, Area RAB +35

SWEL Components: SWEL1-083, SWEL2-005

Photographs

Note: Operations appendix R supplies locker Note: Block wall near equipment

Engineering Report No. WF3-CS-12-00003 Attachment D

Rev. 0 Page 210 of 210