atomdb workshop harvard-smithsonian center for astrophysics cambridge, ma 9-10 august 2012

15
Fitting X-ray Spectra with Imperfect Models Nancy S. Brickhouse Harvard-Smithsonian Center for Astrophysics Acknowledgments to Randall Smith and Adam Foster. This talk is based on benchmarking ATOMDB. Opinions expressed are my own. AtomDB Workshop Harvard-Smithsonian Center for Astrophysics Cambridge, MA 9-10 August 2012

Upload: rocco

Post on 09-Jan-2016

24 views

Category:

Documents


1 download

DESCRIPTION

AtomDB Workshop Harvard-Smithsonian Center for Astrophysics Cambridge, MA 9-10 August 2012. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Fitting X-ray Spectra with Imperfect Models

Nancy S. Brickhouse

Harvard-Smithsonian Center for Astrophysics

Acknowledgments to Randall Smith and Adam Foster.This talk is based on benchmarking ATOMDB.

Opinions expressed are my own.

AtomDB WorkshopHarvard-Smithsonian Center for Astrophysics

Cambridge, MA 9-10 August 2012

Page 2: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

How Atomic Rate Uncertainties Affect Fits to X-ray Spectra

OR If I can’t find a model that fits my

data, have I discovered exotic physics?

Page 3: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Outline

• The Coronal Model: Thermal Plasma in Collisional Ionization Equilibrium (CIE) and Beyond

• Guide to Atomic Rate Uncertainties

• Examples of Benchmark Studies with Capella

• Young Stellar Spectra

• Interpreting the Diffuse Emission in SF Regions

• Lessons

Page 4: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

• Plasma temperature is defined for gas in thermal equilibrium, for which the most probable velocity distribution is the Maxwellian.

Examples of non-thermal plasmas are particle beams, bumps on tails, Kappa distributions.

• Particles of similar mass equilibrate with each other, so e− with e−

and p with p first, and then with each other.

Te ≠ Tp

Energy Distribution Functions

Thermal Plasma or Non-thermal (exotic)?

Page 5: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Electron Temperature (K)

Fra

c. A

bu

nd

.

106 107 108

0

200

-200

1.00

0.10

Red – New (2006)Blue – Old (1998)

Fe24+

Fe16+Fe8+

105

400

-400

CIE or Non-Equilibrium Ionization?

Iron

Bryans et al. 2006

• Ionization equilibrium occurs when collisional ionization by electron impact balances collisional and radiative recombination processes

For short times and/or at low densities the ionization state has not reached its equilibrium value and thus does not reflect Te.

CIE

Page 6: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Line Emission from Collisional Excitation or something else more exotic?

In the “coronal” limit the electron density Ne is low enough that most of the level population is in the ground state.

Flux = ∑ ε (Te) EM(Te) / (4 π R2), where R is the distance,

EM (Te) = ∫ Ne NH dV is the emission measure, and

ε (Te) is the emissivity. It depends on a lot of atomic

physics, e.g. ionization and recombination

rates and collisional excitation rates

Level population by other methods (recombination to an upper level, fluorescence) and metastable levels with long lifetimes give interesting diagnostics for exotic processes.

Page 7: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Guide to Atomic Rate Uncertainties

Typical Possible• Collisional excitation 20 to 30% 5 to 10%

• Radiative decay 20 to 30% 5 to 10%

• Collisional ionization 20% 10%?

• Radiative recombination 25% ?

• Dielectronic recombination 30 to 50% ?

• 2-photon emission 25%?

• Bremsstrahlung 2%

• Wavelengths 0.05 to 2% 0.003%

• Missing processes (e.g. recombination to upper levels)

• Missing lines (a difficult problem to treat in a spectral fit)

Talk to Connor Balance aboutbetter uncertaintyestimates!

Page 8: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

EUV/X-ray Line Ratios from Chandra LETG spectrum of Capella

Predicted X-ray fluxes are too low for all the X-ray lines

Desai et al. 2006

Talk to Connor Balance aboutbetter uncertaintyestimates!

Page 9: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Blending of Fe XIX in the Ne IX Region: Wavelength Errors

Kotochigova et al. 2010

Page 10: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

How complicated can it get? Star formation is pretty messy.

•Hard X-rays: corona

•Soft X-rays: corona, jet, shock

•Absorption by: ISM, disk, accretion stream, nebula

Sample of young star spectra from the Chandra HETG

Page 11: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Furthermore, extended emission and crowded fields cannot be observed with optimal spectral resolution.

• CCD vs Grating for the same star (TW Hya)

ASCA HETG

Page 12: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

And it gets worse. The diffuse nebular emission processes are not all known (e.g. photoionization from hot stars, fast wind shocks?)

From Townsley et al. 2011, ApJS 194 16

Page 13: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Special thanks to Leisa Townsley for asking.

Even with several model components including complex physics, there are many residuals. Are they interesting?

From Townsley et al. 2011, ApJS 194 16

Many of them are near strong lines, suggesting atomic data problems.

Some of the very large problems may be in the absorption models.

Page 14: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Lessons• Thermal plasma in CIE does not provide much spectral information on heating, dynamics, feedback.

• Atomic rate uncertainties > calibration and statistical errors.

• Uncertainties in the charge state balance can lead to inconsistencies in global models.

• Residuals near strong lines are likely related to atomic rate uncertainties. Complex absorption effects will exacerbate this.

• Departures from Maxwellian and CIE will be difficult to establish at CCD resolution.

• Such departures, if established through resolved line ratios with accurate atomic rate data, are critical to getting to the interesting physics.

Page 15: AtomDB Workshop Harvard-Smithsonian Center for Astrophysics  Cambridge, MA   9-10 August 2012

Some Words about Charge Exchange (CX)

• “Highly ionized plasmas don’t wait.” (R. K. Smith)

• Dominance of CX occurs w/ ionized metals, neutral hydrogen, and a rapid transition region.

• However, charge neutrality in a stellar wind means that electronic recombination will occur over short distances.

• CX allows only ~2 X-ray photons, whereas CE keeps going.

• Both recombination processes leadto large G-ratios and large Ly α /Ly β Ratios.

• Absence of Radiative Recombination Continua in CX the main distinction.

Smith & Hughes 2010