atex cable glands - grupo siccisgruposiccis.com/catalogues/atex-cable-glands.pdfatex cable glands...

18
www.gruposiccis.com ATEX CABLE GLANDS

Upload: others

Post on 19-Apr-2020

22 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

www.gruposiccis.com

ATEX CABLE GLANDS

Page 2: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

CONTENTS

Page

BRASS CABLE GLANDS

INTRODUCTION .................................................................................... 2

CABLE GLANDS

DN SERIES .................................................................................. 3

DNC SERIES ............................................................................... 4

DAS SERIES ................................................................................ 5

DAD SERIES ............................................................................... 6

DALD SERIES .............................................................................. 7

DNR SERIES ................................................................................ 8

DNCR SERIES ............................................................................. 9

DASR SERIES .............................................................................. 10

DADR SERIES ............................................................................. 11

ACCESSORIES

PLUGS ........................................................................................ 12

REDUCERS ................................................................................. 13

ADAPTORS ................................................................................ 14

OTHER ACCESSORIES ............................................................... 15

PLASTIC CABLE GLANDS

UNI SERIES............................................................................................. 16

www.gruposiccis.com 1

Page 3: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

CERTIFICATES

Every product is designed and manufactured i.a.w. CENELEC European rules and EN Recommendations. Cable glands and accessories are manufactured for installation in the following areas:

− Safe areas: W.P. IP66 industrial execution − Class 1 div.2: Exe II execution − Class 1 div.1: Exd IIC execution

Certificate No. CEC 05/2045-AET120 by CEC RWTUV-ITALY for II2GD group installation and protection degree IP66 in accordance with CENELEC rules:

− EN 50014 : 1998 + A1-A2 − EN 50018 : 2000 + A1

− EN 50019 : 2000 − EN 50281-1-1 : 1998 + A1

Certificate No. CEC 09 ATEX 023X by CEC RWTUV-ITALY for II2GD group installation and protection degree IP66 in accordance with IEC rules:

− IEC EN 60079-0 : 2004 − IEC EN 60079-1 : 2007

− IEC EN 60079-7 : 2006 − IEC EN 61241-1 : 2004

NOTES

Cabla glands for armoured cables are supplied in normal execution, suitable for 0.3 y 0.9 mm braid or wire

armour. On request, cable glands can be supplied for 1-2,5mm armour wires.

SIZE NPT ANSI B1 20.1 L ISO Mx1.5 ISO 261 L Pg DIN 40430 6

0 3/8” 15 M16 15 Pg9 Pg11

12

1 ½” 18 M20 15 Pg13.5 Pg16

12

2 ¾” 18 M25 15 Pg16 Pg21

12

3 1” 22 M32 15 Pg21 Pg29

12

4 1”1/4 22 M40 15 Pg29 14

5 1”1/2 22 M50 15 Pg36 14

6 2” 22 M63 15 Pg42 Pg48

14

7 2”1/2 27 M75 15 Pg48 14

8 3” 27 M75/85 15

2 www.gruposiccis.com

MATERIALS

Metallic parts − CW614N Brass − AISI 304/316 stainless steel

Corrosion protection: nickel/chrome plated Sealing: EPDM (antiageing rubber, 50-60 shore hardness, suitable for -40ºC y +80ºC). Sylicone on request.

THREADS

− UNI6125 GK (ISO 7/1 Rc) − NPT (ANSI B1 20.1) − ISO Mx1.5 (ISO 261)

On request: BSPP/UNI338 (ISO 7/1 Rp) or Pg (DIN 40430)

INTRODUCTION

Page 4: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DN1.10 M20x1.5

THREAD

CABLE DIMENSIONS

(mm) GLAND DIMENSIONS (mm)

Size T REF. A

C D H E F MIN MAX

0

3/8”NPT-M16x1.5-Pg9/11

½”NPT-M20x1.5-Pg13.5

DN0.7

DN0.10

4 7

7

10 11 16 33 24 26

1 ½”NPT-M20x1.5-

Pg13.5 ¾”NPT-M25x1.5pg16

DN1.8 DN1.10 DN1.13

5.5 8

10.5

8 10.5 13

14 20 41 32 35

2 ¾”NPT-M25x1.5-Pg16 DN2.13 DN2.15 DN2.18

10.5 13

15.5

13 15.5 18

19 25 41 36 39

3 1”NPT-M32x1.5-Pg21 DN3.18 DN3.21 DN3.24

15 18 21

18 21 24

25 32 52 45 49

4 1”1/4NPT-M40x1.5-

Pg29

DN4.24 DN4.27 DN4.30

21 24 27

24 27 30

31 38 53 50 55

5 1”1/2-M50x1.5-Pg36

DN5.27 DN5.30 DN5.33 DN5.36

24 27 30 33

27 30 33 36

37 44 53 57 62

6 2”NPT-M63x1.5-Pg42 DN6.39 DN6.42 DN6.45

36 39 42

39 42 45

47 54 53 67 73

7 2”1/2NPT-M75x1.5-

Pg48

DN7.48 DN7.51 DN7.54

45 48 51

48 51 54

57 65 53 80 88

www.gruposiccis.com 3

1- BODY 2- SEAL 3- PRESS-RING

4- GLAND NUT

II 2 GD EEx e/d IIC IP66

APPLICATION

• Unarmoured cable, outer seal • For general use, indoor and outdoor

DN SERIES

Page 5: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DNC1.10 M20x1.5

THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS (mm)

Size T REF. A

C H E F G MIN MAX

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DNC1.8 DNC1.10 DNC1.13

5.5 8

10.5

8 10.5 13

14 41 32 35 ½”

2 ¾”NPT-M25x1.5-

Pg16

DNC2.13 DNC2.15 DNC2.18

10.5 13

15.5

13 15.5 18

19 41 36 39 ¾”

3 1”NPT-M32x1.5-

Pg21

DNC3.18 DNC3.21 DNC3.24

15 18 21

18 21 24

25 52 45 49 1”

4 1”1/4NPT-M40x1.5-

Pg29

DN4C.24 DNC4.27 DNC4.30

21 24 27

24 27 30

31 53 50 55 1”1/4

5 1”1/2-M50x1.5-

Pg36

DNC5.27 DNC5.30 DNC5.33 DNC5.36

24 27 30 33

27 30 33 36

37 53 57 62 1”1/2

6 2”NPT-M63x1.5-

Pg42

DNC6.39 DNC6.42 DNC6.45

36 39 42

39 42 45

47 53 67 73 2”

4 www.gruposiccis.com

1- BODY 2- SEAL 3- PRESS-RING 4- GLAND NUT

DNC SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• Unarmoured cable, outer seal • Suitable for flexible conduit coupling • For general use, indoor and outdoor • Note: Thread G=ISO 7/1 RP-BSPP. Other threads on request.

Page 6: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DAS1.10 M20x1.5

THREAD CABLE DIMENSIONS

(mm) GLAND DIMENSIONS (mm)

Size T REF. A

C D H E F MIN MAX

0

3/8”NPT-M16x1.5-Pg9/11

½”NPT-M20x1.5-Pg13.5

DAS0.7 DAS0.10

4 7

7 10

11 16 33 24 26

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DAS1.8 DAS1.10 DAS1.13

5.5 8

10.5

8 10.5 13

14 20 41 32 35

2 ¾”NPT-M25x1.5-

Pg16

DAS2.13 DAS2.15 DAS2.18

10.5 13

15.5

13 15.5 18

19 25 41 36 39

3 1”NPT-M32x1.5-

Pg21

DAS3.18 DAS3.21 DAS3.24

15 18 21

18 21 24

25 32 52 45 49

4 1”1/4NPT-M40x1.5-

Pg29

DAS4.24 DAS4.27 DAS4.30

21 24 27

24 27 30

31 38 53 50 55

5 1”1/2-M50x1.5-

Pg36

DAS5.27 DAS5.30 DAS5.33 DAS5.36

24 27 30 33

27 30 33 36

37 44 53 57 62

6 2”NPT-M63x1.5-

Pg42

DAS6.39 DAS6.42 DAS6.45

36 39 42

39 42 45

47 54 53 67 73

7 2”1/2NPT-M75x1.5-

Pg48

DAS7.48 DAS7.51 DAS7.54

45 48 51

48 51 54

57 65 53 80 88

www.gruposiccis.com 5

1- BODY 2- SEAL 3- ARMOUR CLAMPING

RINGS

4- GLAND NUT

DAS SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• Armoured cable • Inner seal under armour and armour grounding • For indoor without armour protection

Page 7: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DAD1.1015 M20x1.5

THREAD CABLE DIMENSIONS (mm) GLAND DIMENSIONS (mm)

Size T REF. A B

C D H E F MIN MAX MIN MAX

0

3/8”NPT-M16x1.5-Pg9/11

½”NPT-M20x1.5-Pg13.5

DAD0.7 DAD0.10

4 7

7 10

10 15 11 16 53 24 26

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DAD1.8* DAD1.10* DAD1.13*

5.5 8

10.5

8 10.5 13

10 14

15 19

11 20 65 32 35

2 ¾”NPT-M25x1.5-

Pg16

DAD2.13* DAD2.15* DAD2.18*

10.5 13

15.5

13 15.5 18

15 19

20 24

14 25 65 36 39

3 1”NPT-M32x1.5-

Pg21

DAD3.18* DAD3.21* DAD3.24*

15 18 21

18 21 24

20 25

26 31

25 32 82 45 49

4 1”1/4NPT-M40x1.5-

Pg29

DAD4.24* DAD4.27* DAD4.30*

21 24 27

24 27 30

26 31

32 37

31 38 83 50 55

5 1”1/2-M50x1.5-

Pg36

DAD5.27* DAD5.30* DAD5.33* DAD5.36*

24 27 30 33

27 30 33 36

31 36

37 43

37 44 83 57 62

6 2”NPT-M63x1.5-

Pg42

DAD6.39* DAD6.42* DAD6.45*

36 39 42

39 42 45

42 47

48 53

47 54 83 67 73

7 2”1/2NPT-M75x1.5-

Pg48

DAD7.48* DAD7.51* DAD7.54*

45 48 51

48 51 54

52 58

58 64

57 65 83 80 88

6 www.gruposiccis.com

1- BODY 2- INNER SEAL 3- ARMOUR CLAMPING

RING 4- MIDDLE BODY 5- OUTER SEAL 6- WASHER 7- GLAND NUT

DAD SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• Armoured cable • Inner and outer seals, armour grounding • For outdoor with complete protection of cable armour

Page 8: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DALD1.1015 M20x1.5

CABLE DIMENSIONS (mm) GLAND DIMENSIONS (mm)

Size T REF. A B

C D H E F MIN MAX MIN MAX

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DALD1.8* DALD1.10* DALD1.13*

4.5 6

8.5

6 8.5 11

10 14

15 19

14 20 41 32 35

2 ¾”NPT-M25x1.5-

Pg16

DALD2.13* DALD2.15* DALD2.18*

8.5 11

13.5

11 13.5 16

15 19

20 24

19 25 41 36 39

3 1”NPT-M32x1.5-

Pg21

DALD3.18* DALD3.21* DALD3.24*

13 16 19

16 19 22

20 25

26 31

25 32 52 45 49

4 1”1/4NPT-

M40x1.5-Pg29

DALD4.24* DALD4.27* DALD4.30*

19 22 25

22 25 28

26 31

32 37

31 38 53 50 55

5 1”1/2-M50x1.5-

Pg36

DALD5.27* DALD5.30* DALD5.33* DALD5.36*

22 25 28 31

25 28 30 34

31 36

37 43

37 44 53 57 62

6 2”NPT-M63x1.5-

Pg42

DALD6.39* DALD6.42* DALD6.45*

34 37 40

37 40 43

42 47

48 53

47 54 53 67 73

7 2”1/2NPT-

M75x1.5-Pg48

DALD7.48* DALD7.51* DALD7.54*

43 46 49

46 49 52

52 58

58 64

57 65 53 80 88

www.gruposiccis.com 7

1- BODY 2- INNER SEAL 3- LEAD RING 4- ARMOUR CLAMPING

RING 5- MIDDLE BODY 6- OUTER SEAL 7- WASHER

8- GLAND NUT

DALD SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• For armoured and lead sheated cable • Inner and outer seals, armour and lead grounding • For outdoor with complete protection of cable armour

Page 9: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DNR1.10 M20x1.5

THREAD CABLE DIMENSIONS (mm) GLAND DIMENSIONS (mm)

Size T REF. A

C D H E F MIN MAX

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DNR1.8 DNR1.10 DNR1.13

5.5 8

10.5

8 10.5 13

12 20 41 32 35

2 ¾”NPT-M25x1.5-

Pg16

DNR2.13 DNR2.15 DNR2.18

10.5 13

15.5

13 15.5 18

17 25 41 36 39

3 1”NPT-M32x1.5-

Pg21

DNR3.18 DNR3.21 DNR3.24

15 18 21

18 21 24

23 32 52 45 49

4 1”1/4NPT-

M40x1.5-Pg29

DNR4.24 DNR4.27 DNR4.30

21 24 27

24 27 30

29 38 53 50 55

5 1”1/2-M50x1.5-

Pg36

DNR5.27 DNR5.30 DNR5.33 DNR5.36

24 27 30 33

27 30 33 36

35 44 53 57 62

6 2”NPT-M63x1.5-

Pg42

DNR6.39 DNR6.42 DNR6.45

36 39 42

39 42 45

45 54 53 67 73

7 2”1/2NPT-

M75x1.5-Pg48

DNR7.48 DNR7.51 DNR7.54

45 48 51

48 51 54

55 65 53 80 88

8 www.gruposiccis.com

1- BODY 2- SEAL 3- PRESS-RING 4- GLAND NUT 5- CHAMBER FOR

COMPOUND

DNR SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• Unarmoured cable, outer seal • Suitable for enclosures over 2 litres with sparking equipment (EN 60079-14 for 10.3.2). • For general use, indoor and outdoor

Page 10: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DCNR1.10 M20x1.5

THREAD CABLE DIMENSIONS(mm) GLAND DIMENSIONS (mm)

Size T REF. A

C H E F G MIN MAX

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DNCR1.8 DNCR1.10 DNCR1.13

5.5 8

10.5

8 10.5 13

12 42 32 35 ½”

2 ¾”NPT-M25x1.5-

Pg16

DNCR2.13 DNCR2.15 DNCR2.18

10.5 13

15.5

13 15.5 18

17 45 36 39 ¾”

3 1”NPT-M32x1.5-

Pg21

DNCR3.18 DNCR3.21 DNCR3.24

15 18 21

18 21 24

23 54 45 49 1”

4 1”1/4NPT-

M40x1.5-Pg29

DNCR4.24 DNCR4.27 DNCR4.30

21 24 27

24 27 30

29 55 50 55 1”1/4

5 1”1/2-M50x1.5-

Pg36

DNCR5.27 DNCR5.30 DNCR5.33 DNCR5.36

24 27 30 33

27 30 33 36

35 55 57 62 1”1/2

6 2”NPT-M63x1.5-

Pg42

DNCR6.39 DNCR6.42 DNCR6.45

36 39 42

39 42 45

45 55 67 73 2”

www.gruposiccis.com 9

1- BODY 2- SEAL 3- PRESS-RING 4- GLAND NUT 5- CHAMBER FOR

COMPOUND

DCNR SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• Unarmoured cable, outer seal • Suitable for flexible conduit coupling • Suitable for enclosures over 2 litres with sparking equipment (EN 60079-14 for 10.3.2). • For general use, indoor and outdoor • NOTE: Thread G=ISO 7/1 RP-BSPP. Other threads on request

Page 11: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Designation example : DASR1.10 M20x1.5

THREAD CABLE DIMENSIONS (mm) GLAND DIMENSIONS (mm)

Size T REF. A

C D H E F MIN MAX

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DASR1.8 DASR1.10 DASR1.13

5.5 8

10.5

8 10.5 13

12 20 41 32 35

2 ¾”NPT-M25x1.5-

Pg16

DASR2.13 DASR2.15 DASR2.18

10.5 13

15.5

13 15.5 18

17 25 41 36 39

3 1”NPT-M32x1.5-

Pg21

DASR3.18 DASR3.21 DASR3.24

15 18 21

18 21 24

25 32 52 45 49

4 1”1/4NPT-

M40x1.5-Pg29

DASR4.24 DASR4.27 DASR4.30

21 24 27

24 27 30

29 38 53 50 55

5 1”1/2-M50x1.5-

Pg36

DASR5.27 DASR5.30 DASR5.33 DASR5.36

24 27 30 33

27 30 33 36

35 44 53 57 62

6 2”NPT-M63x1.5-

Pg42

DASR6.39 DASR6.42 DASR6.45

36 39 42

39 42 45

45 54 53 67 73

7 2”1/2NPT-

M75x1.5-Pg48

DASR7.48 DASR7.51 DASR7.54

45 48 51

48 51 54

55 65 53 80 88

10 www.gruposiccis.com

1- BODY 2- SEAL 3- ARMOUR CLAMPING RING 4- GLAND NUT 5- CHAMBER FOR

COMPOUND

II 2 GD EEx e/d IIC IP66

APPLICATION

• Unarmoured cable, inner seal under armour and armour grounding • Suitable for enclosures over 2 litres with sparking equipment (EN 60079-14 for 10.3.2). • For indoor without armour protection

DASR SERIES

Page 12: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

1-

Designation example : DADR1.10 M20x1.5

THREAD CABLE DIMENSIONS (mm) GLAND DIMENSIONS (mm)

Size T REF. A B

C D H E F MIN MAX MIN MAX

1

½”NPT-M20x1.5-Pg13.5 ¾”NPT-

M25x1.5pg16

DADR1.8* DADR1.10* DALD1.13*

5.5 8

10.5

8 10.5 13

10 14

15 19

12 20 65 32 35

2 ¾”NPT-M25x1.5-

Pg16

DADR2.13* DADR2.15* DADR2.18*

10.5 13

15.5

13 15.5 18

15 19

20 24

17 25 65 36 39

3 1”NPT-M32x1.5-

Pg21

DADR3.18* DADR3.21* DADR3.24*

15 18 21

18 21 24

20 25

26 31

23 32 82 45 49

4 1”1/4NPT-

M40x1.5-Pg29

DADR4.24* DADR4.27* DADR4.30*

21 24 27

24 27 30

26 31

32 37

29 38 83 50 55

5 1”1/2-M50x1.5-

Pg36

DADR5.27* DADR5.30* DADR5.33* DADR5.36*

24 27 30 33

27 30 33 36

31 36

37 43

35 44 83 57 62

6 2”NPT-M63x1.5-

Pg42

DADR6.39* DADR6.42* DADR6.45*

36 39 42

39 42 45

42 47

48 53

45 54 83 67 73

7 2”1/2NPT-

M75x1.5-Pg48

DADR7.48* DADR7.51* DADR7.54*

45 48 51

48 51 54

52 58

58 64

55 65 83 80 88

www.gruposiccis.com 11

1- BODY 2- INNER SEAL 3- ARMOUR CLAMPING RING 4- MIDDLE BODY 5- OUTER SEAL 6- WASHER 7- GLAND NUT 8- CHAMBER FOR

COMPOUND

DADR SERIES

II 2 GD EEx e/d IIC IP66

APPLICATION

• Armoured cable, inner seal under armour and armour grounding • Suitable for enclosures over 2 litres with sparking equipment (EN 60079-14 for 10.3.2). • For indoor, with complete protection of cable armour

Page 13: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

SIZE THREAD 0 1 2 3 4 5 6 7 8

U ½” ¾” 1” 1”1/4 1”1/2 2” 2”1/12 3”

N ½” ¾” 1” 1”1/4 1”1/2 2” 2”1/12 3”

B 3/8” ½” ¾” 1” 1”1/4 1”1/2 2” 2”1/12 3”

I M16 M20 M25 M32 M40 M50 M63 M75 M85

P Pg11 Pg13.5 Pg16 Pg21 Pg29 Pg36 Pg42 Pg48

12 www.gruposiccis.com

Designation:

Txa

T: Plug x: Thread type (M) a: Thread size (M) Ex: TI0= Plug M16

ACCESORIES

II 2 GD EEx e/d IIC IP66

THREADS DESIGNATION

II 2 GD EEx e/d IIC IP66

PLUGS T SERIES

Male stopping plugs, suitable for enclosure entries

Page 14: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

www.gruposiccis.com 13

Designation:

R xa yb

R: reducer x: Thread type (M) a: Thread size (M) y: Thread type (F) b: Thread size (F) Ej: R I1 I3

Designation:

RM xa yb

RM: reducer x: Thread type (M) a: Thread size (M) y: Thread type (M) b: Thread size (M) Ex: RM I1 I3

Designation:

RF xa yb

RF: reducer x: Thread type (F) a: Thread size (F) y: Thread type (F) b: Thread size (F) Ex: RF I1 I3

ACCESORIES

II 2 GD EEx e/d IIC IP66

REDUCERS R SERIES

Reducers male-female. Male and female have the same thread type.

II 2 GD EEx e/d IIC IP66

REDUCERS RM SERIES

Reducers male/male. Both males with same thread type.

II 2 GD EEx e/d IIC IP66

REDUCERS RF SERIES

Reducers female/female. Both females with same thread type. .

Page 15: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

14 www.gruposiccis.com

Designation:

A xa yb

R: Adaptor x: Thread type (M) a: Thread size (M) y: Thread type (F) b: Thread size (F)

Ex: A I1 N1

Designation:

AM xa yb

AM: Adaptor x: Thread type (M) a: Thread size (M) y: Thread type (M) b: Thread size (M) Ex: AM I1 N1

Designation:

AF xa yb

AF: Adaptor x: Thread type (F) a: Thread size (F) y: Thread type (F) b: Thread size (F) Ex: AM I1 N1

ACCESORIES

II 2 GD EEx e/d IIC IP66

ADAPTORS A SERIES

Adaptors male/female. Male and female have different thread type.

II 2 GD EEx e/d IIC IP66

ADAPTORS AM SERIES

Adaptors male/male.

II 2 GD EEx e/d IIC IP66

ADAPTORS AF SERIES

Adaptors female/female

Page 16: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Sealing rubber

Rubber protection

Locknuts

Gaskets

Earthing tag

www.gruposiccis.com 15

Inner seal Outer seal Materials:

- EPDM

- Sylicone

PTD Series

LB Series (BSPP/UNI 338) LI Series (ISO Mx1.5)

LP Series (Pg)

GB Series (BSPP/UNI 338) GI Series (ISO Mx1.5)

GP Series (Pg)

ETB Series (BSPP/UNI 338) ETI Series (ISO Mx1.5)

ETP Series (Pg)

ACCESORIES

II 2 GD EEx e/d IIC IP66

OTHER ACCESORIES

Page 17: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

ATEX CABLE GLANDS

Part

number P

Hole

(mm)

A

diam.

(mm)

B

(mm)

C

(mm)

L

min-max

(mm)

PCE-M16 M16 16,5 6-10 22 8 27-32

PCE-M20 M20 20,5 8-14 24 8 34-39

PCE-M25 M25 25,5 13-18 33 11 36-42

PCE-M32 M32 32,5 18-25 42 11 41-47

PCE-M40 M40 40,5 22-32 53 13 51-58

PCE-M50 M50 50,5 30-38 60 13 52-60

PCE-M63 M63 63,5 34-44 65 13 52-60

16 www.gruposiccis.com

II 2 GD EEx e II IP65/7

CHARACTERISTICS

• Material: polyamide

• Certificate LOM 01 ATEX 2038x

• Ambient temperature -25ºC +90ºC • Unarmoured cable

PCE SERIES

Page 18: ATEX CABLE GLANDS - Grupo Siccisgruposiccis.com/catalogues/ATEX-CABLE-GLANDS.pdfATEX CABLE GLANDS Designation example: DNC1.10 M20x1.5 THREAD CABLE DIMENSIOSN (mm) GLAND DIMENSIONS

SICCIS S.A.

Avda. metalurgia 15 33211 – Gijón

Asturias Tel. 985325100 Fax. 985322252

www.gruposiccis.com [email protected]