ateis-pava2013-online.pdf

60
D ELIVERING Y OUR M ESSAGE Catalogue 2013 Public Address - Voice Alarm Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers

Upload: arman-ul-nasar

Post on 01-Jan-2016

126 views

Category:

Documents


1 download

DESCRIPTION

PAVA

TRANSCRIPT

Page 1: ateis-PAVA2013-online.pdf

Del iver ing Your Message

C a t a l o g u e 2 0 1 3

Public Address - Voice Alarm

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

Page 2: ateis-PAVA2013-online.pdf

Del iver ing Your Message

IDA8-series of Digital Public Address and Voice

Alarm products are leading the industry for

Emergency Systems. IDA8-series is installed into

highly demanding public transportation networks

in Europe, where it is dominating the market for

high-tech audio communication solutions that

combine redundant networks on CAT5, Fibre-

optic and TCP-IP.

IDA8-series of products is the ideal choice for

commercial applications where scheduled events,

background music are an integrated part of the

voice-alarm system. Both applications guaranteed

for superb quality of sound and intelligibility.

IDA8-series of products are complying to the

EN54-16, ISO 7240-16 and BS5839/8

Page 3: ateis-PAVA2013-online.pdf

3

Public AdressVoice Alarm

IndexIDA8 system

Networkable PAVA system – Controller UnitIDA8C 6

IDA8S Networkable PAVA system – Slave UnitIDA8S 10

Networkable PAVA system – Slave Unit – A /B-zoningIDA8SAB 14

Networkable PAVA system – Low impedance Slave UnitIDA8SL 18

ATEIS Net Secured Audio Network CardNET-CX 23

ATEÏS StudioIntegrated Operat ion Sof tware

ATEÏS Studio 24

DIVA8 SystemCompact PAVA system – Master Unit

DIVA8M G2 28Compact PAVA system – Slave Unit

DIVA8S G2 32

AmplifiersDigital Power Amplif iers

DPAfour 38Sinewave Power Amplif iers

SPA 40Basic Power Amplif iers

BPA 42

Battery ChargerCharger and monitor ing unit - EN 54-4

SONAES 44

Consoles & AccessoriesColour Touch-Screen Secure Paging Console

PSS 48Wallmount Monitored Touch-Screen Paging Console

CD-Touch 50Table Top Microphone Consoles for Commercial Use

PPM8 52Wallmount Monitored Paging Console

CD-8 54Wallmount Monitored Paging Console

CD-16 56Alarm Input Inter face for IDA8-System and DIVA8-System

URGP32in 59

Page 4: ateis-PAVA2013-online.pdf

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

ATEÏS Europe B.V. Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDS

Phone: +31 (0)10 2088690 - Fax: +31 (0)10 [email protected]

ATEÏ

S re

serv

e th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otic

eHE

LPRO

D.CO

M -

Pro

duct

pic

ture

s, R

ober

t Pee

k Fo

togr

afie

- F

otol

ia

IDA8S

Networkable PAVA system Slave Unit

IDA8SAB

Networkable PAVA system Slave Unit – A/B-zoning

IDA8SL

Networkable PAVA system Low impedance Slave Unit

Page 5: ateis-PAVA2013-online.pdf

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

IDA8 System

IDA8C

Networkable PAVA system Controller Unit

IDA8 is a third-generation modular

system that complies with current

architectural demands requiring

IP and/or fibreoptic networking to

allow for even the most complex of

system designs.

IDA8 responds to Public Address

and Voice Alarm requirements

as stated in EN54-16, ISO 7240-

16 and BS5839/8, with specific

attributes for compliance in large

installations.

Page 6: ateis-PAVA2013-online.pdf

6

IDA8 system

IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ConneCtivity:

The IDA8C Controller unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, with front panel access for a fully monitored fireman’s microphone and emergency message trigger buttons. IDA8C also supports amplifier monitoring with hot-swap amplifiers and loudspeaker line impedance monitoring. It can support up to four PSS-AS monitored microphone consoles and up to eight monitored amplifiers plus two back-up amplifiers, paging into 8 different zones per unit with A/B line detection according to BS5939 part 8. Two card slots are provided for either 4-channel 0dB audio input or 4-channel audio cards. Optional AES/EBU cards are also available.

Each IDA8C input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines. Up to 4 hours of digital messaging (WAV format) can be stored for live or pre-recorded playback. Digital audio files are uploaded from a computer to the IDA8S through the user-friendly ATEÏS Studio GUI. Several messages can be played simultaneously into different zones: up to 4 messages from a single IDA8C Controller or a total of 48 messages across an IDA8 system (controller with slaves). A built-in loudspeaker on the IDA8C allows selective feedback for all sources and 100V output signals.

IDA8S Slave units can extend the system configuration with an additional 8 inputs and 8 outputs and 2 back-up amplifiers. The slave units are available as single zone (IDA8S) or with A/B speaker line configurations (IDA8SAB), or for Low-impedance monitoring (IDA8SL).

The IDA8C Controller unit enables operators to see a detailed overview of the operational status of the entire PA system at the press of a button. It is able to run an impedance scan of all components connected to it, covering not only the input paging consoles but also connectors, cabling, processing blocks such as compressors and limiters, delay lines, the network and loudspeakers.

The IDA8C Controller operates either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored. IDA8C is easily configured using the PC-based ATEÏS Studio global software. Once programmed, the system will operate independently (off-line) without a PC having to be connected.

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839/8, all IDA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally-generated pilot tone is available for monitoring impedance on the loudspeaker lines.

The system can handle 256 priorities for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements. The controller monitors the status of all the equipment in the system, reports status changes and logs the last 999 fault messages in the system. The log can be accessed on the front-panel IDA8C display or on a PC through ATEÏS Studio. The IDA8C system (controller and slaves) supports redundant network cabling, wired as a redundant loop.

Main CharaCteriStiCS

•Public address and emergency sound system control unit

•Fully digital with 8 audio inputs and 8 audio outputs

•4 dedicated and monitored PDC-ports for firemen’s microphones

•2 dedicated audio in and outputs for back-up amplifiers

•Enhanced loudspeaker line surveillance for AB-zoned installation

•Simultaneous control and routing of 48 audio channels over dedicated network

•Equiped as standard with RJ45 network cards (NET-C1) for links up to 100 m

• Optional Fibreoptic cards for links up to 20 km

•9 supervised control inputs and 8 control outputs

•Ethernet interface for configuration, control, diagnostics and logging

•Digital storage for up to 4 hours of prerecorded messages

• 4 message players

• Stores the last 999 fault events

• EN54-16 certified

NETWORKABLE PAVA SYSTEM – CONTROLLER UNIT

IDA8C

Page 7: ateis-PAVA2013-online.pdf

IDA8 system

7

inStallation noteS

NETWORKABLE PAVA SYSTEM – CONTROLLER UNIT

IDA8C

Page 8: ateis-PAVA2013-online.pdf

8

IDA8 system

PartS inCluded

Quantities Components

1 IDA8Cxx Controller unit

1 Power cord

1 Set of mounting brackets for 19” rack

1 Set of connectors

1 Ateis Studio software GUI

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 48 W

Battery power supply

Voltage 18 - 26 VDC

Performance

Frequency response -3 dB @ 20 Hz and 20 kHz

Line inputs (Optional audio input card)

Connector 3-pin phoenix

Frequency response -3 dB @ 20 Hz and 20 kHz

S/N >90 dBA

THD < 0,1% @ 1 kHz

Input sensivity 770 mV

Input impedance 20 kohm

Line outputs (Optional audio output card)

Connector 3-pin phoenix

S/N >-85 dBu

THD < 0,02% @ 1 kHz

Signal 770 mV

Output impedance <300 ohm

Loudspeaker lines in 8 x 100 V

Rated load resistance 20 ohm (100 V)

Rated load capacitance 250 nF (100 V)

Rated output power(per channel)

500 W (cont. at 40°C)

Loudspeaker lines out 8 x (A+B)

Rated load resistance 20 ohm (100 V)

Rated load capacitance 250 nF (100 V)

Rated output power(per channel) 500 W (cont. at 40°C)

Mechanical

Dimensions (H x W x D)

With 19” rackmount brackets 88 x 483 x 305 mm

Weight 5.36 kg (11,8lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Information

IDA8C-C1-IO Controller with NET-C1 card & 4 audio inputs & 4 audio outputs

IDA8C-C1-2I Controller with NET-C1 card & 8 audio inputs

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

ControlS and indiCatorS

Front

• 3,5” full colour touch-screen LCD display

• Zone selection buttons

• EVAC-start

• Fireman’s microphone

• Status indicators

Rear

• Voltage selector

interConneCtionS

Front

• Firemen’s microphone

Rear

• Mains input

• Battery backup input

• 9 control inputs

• 8 control outputs

• 4 analogue audio mic/line inputs

• 4 analogue audio line inputs

• Ethernet

• LOCAL network in/out card

• Free slot for GLOBAL-network card

• 8 amplifier in and outputs

• 2 connections for back-up amplifiers

• 4 monitored paging console inputs

NETWORKABLE PAVA SYSTEM – CONTROLLER UNIT

IDA8C

Page 9: ateis-PAVA2013-online.pdf

9

IDA8 system

1. Fireman microphone active

2. Fireman microphone input

3. Fireman microphone hook

4. Monitoring loudspeaker (Audible warning)

5. Bypass mode

6. General fault

7. System fault

8. Global EVAC

9. Bypass monitoring

10. 3.5” Touch screen

11. ESC - button

12. OK button

13. Up button

14. Down button

15. Plus button

16. Minus button

17. EVAC indicators

18. FAULT indicators

19. RESET button

20. Power

21. Network

22. EVAC button

1. Speaker zone outputs (A+B)

2. Back-up amplifiers (2x)

3. Amplifier 0dB line outputs

4. Bypass mode contact input

5. EVAC and GF output contact

6. PDC-ports for secured paging con-soles

7. Ethernet

8. Local network card

9. Global network card

10. Audio I/O

11. Telephone line input

12. Telephone controller

13. Bypass mode outputs

14. Contact outputs, 8x

15. Contact inputs, 9x

16. 24VDC slave output

17. 24VDC back-up input

18. AC power socket

NETWORKABLE PAVA SYSTEM – CONTROLLER UNIT

IDA8C

Page 10: ateis-PAVA2013-online.pdf

10

IDA8 system

IDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT

IDA8S

IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ConneCtivity:

The IDA8S Slave unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, along with amplifier monitoring for hot-swap amplifiers and loudspeaker line impedance monitoring. It can support up to two PSS-AS monitored microphone consoles and up to eight monitored amplifiers plus two backup amplifiers, paging into 8 different zones per unit with line detection. Two card slots can fitted with optional 4-channel analogue audio input/outputs cards or 4-channel audio AES/EBU cards (max two cards per device).

IDA8S Slave units extend the IDA8 system configuration with an additional 8 output zones and 2 back-up amplifiers. Each input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines. Up to 4 hours of digital messaging (WAV format) can be stored for live or pre-recorded playback. Digital audio files are uploaded from a computer to the IDA8S through the user-friendly ATEÏS Studio GUI. Several messages can be played simultaneously into different zones: up to 4 messages from a single IDA8S Slave or a total of 48 messages across an IDA8 system (controller with slaves).

The IDA8S Slave operates either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored. The IDA8S Slave also supports redundant loop network cabling. IDA8S is easily configured using the PC-based ATEÏS Studio global software. Once programmed, the system will operate independently (off-line) without a PC having to be connected.

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839/8, all IDA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally-generated pilot tone is available for monitoring impedance on the loudspeaker lines.

The system can handle 256 priorities for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements. The controller monitors the status of all the equipment in the system, reports status changes and logs error details. The log can be accessed on the front-panel IDA8C display or on a PC through ATEÏS Studio.

Main CharaCteriStiCS

•Public address and emergency sound system slave unit

•Fully digital with Optional: 8 audio inputs and 8 audio outputs

•2 dedicated audio in and outputs for back-up amplifiers

•2 dedicated and monitored PDC-ports for fireman’s microphones

•Enhanced loudspeaker line surveillance for zoned installations

•Simultaneous control and routing of 48 audio channels over dedicated network

•Equipped as standard with RJ45 network cards for links up to 100m

• Optional Fibreoptic cards for links up to 20 km

•9 supervised control inputs and 8 control outputs

•Ethernet interface for configuration, control, diagnostics and logging

•Digital storage for up to 4 hours of pre-recorded messages

• 4 message players

• EN54-16 certified

Page 11: ateis-PAVA2013-online.pdf

IDA8 system

11

IDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT

IDA8S

inStallation noteS

Page 12: ateis-PAVA2013-online.pdf

12

IDA8 system

PartS inCluded

Quantities Components

1 IDA8Sxx Slave unit

1 Power cord

1 Set of mounting brackets for 19” rack

1 Set of connectors

1 Ateis Studio software GUI

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 48 W

Battery power supply

Voltage 18 - 26 VDC

Performance

Frequency response -3 dB @ 20 Hz and 20 kHz

Line inputs (Optional input card)

Connector 3-pin phoenix (electronically balanced)

Frequency response +/-3 dB @ 20 Hz and 20 kHz

S/N >90 dBA

THD < 0,1% @ 1 kHz

Input sensitivity 770 mV

Input impedance 20 kOhm

Line outputs (Optional output card)

Connector 3-pin phoenix

S/N >-85 dBu

THD < 0,02% @ 1 kHz

Signal 770 mV

Output impedance < 300 Ohm

Loudspeaker lines in 8 x 100 V

Rated load resistance 20 ohm (100 V)

Rated load capacitance 250 nF (100 V)

Rated output power(per channel)

500 W (cont. at 40°C)

Loudspeaker lines out 8 x

Rated load resistance 20 ohm (100 V)

Rated load capacitance 250 nF (100 V)

Rated output power(per channel) 500 W (cont. at 40°C)

IDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT

IDA8S

Mechanical

Dimensions (H x W x D)

for 19” rack use, with brackets

88 x 483 x 285 mm

Weight

IDA8S 4.2 kg (9.25 lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Information

IDA8S-C1 Slave with NET-C1 card

IDA8S-C1-IO Slave with NET-C1 card & 4 audio inputs & 4 audio outputs

IDA8S-C1-2I Slave with NET-C1 card & 8 audio inputs

IDA8S-C1-2O Slave with NET-C1 card & 8 audio outputs

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

ControlS and indiCatorS

Front

• Status LEDs

• Zone LEDs

• Power LEDs

Rear

• Voltage selector

interConneCtionS

Rear

• Mains input

• Battery backup input

• 9 control inputs

• 8 control outputs

• Optional 4 analogue audio mic/line inputs

• Optional 4 analogue line audio inputs

• 2 system LOCAL-network connections

• 8 amplifier in and outputs

• 2 connections for back-up amplifiers

Page 13: ateis-PAVA2013-online.pdf

13

IDA8 system

1. System fault

2. General fault

3. Bypass mode

4. Bypass monitoring

5. Global EVAC

6. EVAC indicators

7. Power

8. Network

9. FAULT indicators

1. Speaker zone outputs (8x)

2. Back-up amplifiers (2x)

3. Amplifier 0dB line outputs

4. Bypass mode outputs

5. PDC-ports for secured paging consoles

6. Local network card

7. Audio I/O (Optional)

8. 8 Contact outputs

9. 9 Contact inputs

10. 24 VDC input

11. 24 VDC back-up input

IDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT

IDA8S

Page 14: ateis-PAVA2013-online.pdf

14

IDA8 system

IDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT – A/B ZONING

IDA8SAB

IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ConneCtivity:

The IDA8SAB Slave unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, along with amplifier monitoring with hot-swap amplifiers and loudspeaker line-impedance line monitoring. It can support up to two PSS-AS monitored microphone consoles, up to eight monitored amplifiers plus two backup amplifiers and paging into 8 different zones per unit with A/B line detection according to the BS 5939-part 8. Two rear card slots can be fitted with optional 4-channel analogue audio in/output cards 4 channel AES/EBU cards for digital audio in/out.

IDA8SAB Slave units can extend the IDA8 system configuration with an additional 8 output zones and 2 back-up amplifiers. Up to 4 hours of digital messaging can be stored in the unit for live or scheduled playback. Files are uploaded in WAV format from a computer using the ATEÏS Studio system GUI. Several messages can be played simultaneously into different zones: up to 4 from a single IDA8SAB or a total of 48 messages across a full IDA8 system with slaves.

Each input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines.

IDA8SAB is easily configured with PC-based ATEÏS Studio global software. Once programmed, the system will run independently without a PC connected. The IDA8SAB Slave operates either on AC mains power or on a 24V DC battery power supply for emergency back-up, with automatic switchover. Both of the power supplies are monitored

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839:pt8, all system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally generated pilot tone is available for monitoring impedance on the loudspeaker lines. The IDA8SL Slave supports redundant network cabling as a redundant loop. The system can handle 256 priorities, for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements.

Main CharaCteriStiCS

•Public address and emergency sound system slave unit

•Fully digital with up to 8 audio inputs and outputs (optional)

•2 dedicated and monitored PDC-ports for fire-man’s microphones

•2 dedicated audio in and outputs for back-up amplifiers

•Enhanced loudspeaker line surveillance for AB-zoned installations

•Simultaneous control and routing of 48 audio channels over dedicated network

•Equipped as standard with RJ45 network cards for links up to 100 m

• Optional fibreoptic cards for links up to 20 km

• 9 supervised control inputs and 8 control outputs

•Ethernet interface for configuration, control, diagnostics and logging

•Digital storage for up to 4 hours of pre-recorded messages

• 4 message players

• EN54-16 certified

Page 15: ateis-PAVA2013-online.pdf

IDA8 system

15

inStallation noteS

IDA8SABIDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT – A/B ZONING

Page 16: ateis-PAVA2013-online.pdf

16

IDA8 system

PartS inCluded

Quantities Components

1 IDA8SAB Slave unit

1 Power cord

1 Set of mounting brackets for 19” rack

1 Set of connectors

1 Ateis Studio software GUI

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 48 W

Battery power supply

Voltage 18 - 26 VDC

Performance

Frequency response -3 dB @ 20 Hz and 20 kHz

Line inputs (OPTIONAL)

Connector 3-pin phoenix (electronically balanced)

Frequency response +/-3 dB @ 20 Hz and 20 kHz

S/N > 90 dBA

THD < 0,1% @ 1 kHz

Input sensitivity 770 mV

Input impedance 20 kohm

Line outputs (OPTIONAL)

Connector 3-pin phoenix

S/N > -85 dBu

THD < 0,02% @ 1 kHz

Signal 770 mV

Output impedance < 300 Ohm

Loudspeaker lines in 8 x 100 V

Rated load resistance 20 ohm (100 V)

Rated load capacitance 250 nF (100 V)

Rated output power(per channel)

500 W (cont. at 40°C)

Loudspeaker lines out 8x (A+B)

Rated load resistance 20 ohm (100 V)

Rated load capacitance 250 nF (100 V)

Rated output power(per channel) 500 W (cont. at 40°C)

Mechanical

Dimensions (H x W x D)

(including rackmount brackets) 2U, 88 x 483 x 289 mm

Weight

IDA8SAB 5 kg (11 lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Information

IDA8SAB-C1 Slave with NET-C1 card

IDA8SAB-C1-IO Slave with NET-C1 card & 4 audio inputs & 4 audio outputs

IDA8SAB-C1-2I Slave with NET-C1 card & 8 audio inputs

IDA8SAB-C1-2O Slave with NET-C1 card & 8 audio outputs

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

ControlS and indiCatorS

Front

• Status LEDs

• Zone LEDs

• Power LEDs

Rear

• Voltage selector

interConneCtionS

Rear

• Mains input

• Battery backup input

• 9 control inputs

• 8 control outputs

• 4 analogue audio mic/line inputs (optional)

• 4 analogue audio line inputs (optional)

• 2 system LOCAL-network connections

• 8 amplifier in and outputs

• 2 connections for back-up amplifiers

• 2 monitored paging console inputs

IDA8SABIDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT – A/B ZONING

Page 17: ateis-PAVA2013-online.pdf

17

IDA8 system

1. System fault

2. General fault

3. Bypass mode

4. Bypass monitoring

5. Global EVAC

6. EVAC indicators

7. Power

8. Network

9. FAULT indicators

1. Speaker zone outputs (A+B)

2. 2 Back-up amplifier outputs

3. Amplifier 0dB line outputs

4. Bypass mode outputs

5. PDC-ports for secured paging consoles

6. Local network card

7. Audio I/O (optional)

8. Telephone line input

9. Telephone controller

10. 8 Contact outputs

11. 9 Contact inputs

12. 24 VDC slave output

13. 24 VDC back-up input

14. AC power socket

IDA8SABIDA8 NETWORKABLE PAVA SYSTEM – SLAVE UNIT – A/B ZONING

Page 18: ateis-PAVA2013-online.pdf

18

IDA8 system

IDA8 NETWORKABLE PAVA SYSTEM – Low Impedance Slave Unit

IDA8SL

IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ConneCtivity:

The IDA8SL Low-Impedance Slave unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, along with amplifier monitoring with hot-swap amplifiers and low-impedance line monitoring. It can support up to two PSS-AS monitored microphone consoles, up to four monitored amplifiers plus two backup amplifiers and paging into 4 different zones per unit with line detection. Each input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines.

IDA8SL Slave units can extend the IDA8 system configuration with an additional 4 output zones and 2 back-up amplifiers. Up to 4 hours of digital messaging can be stored in the unit for live or scheduled playback. Files are uploaded in WAV format from a computer using the ATEÏS Studio system GUI. Several messages can be played simultaneously into different zones: up to 4 from a single IDA8SL or a total of 48 messages across a full IDA8 system with slaves.

IDA8SL is easily configured with PC-based ATEÏS Studio global software. Once programmed, the system will run independently without a PC connected. The IDA8SL-Slave operates either on AC mains power or on a 24V DC battery power supply for emergency back-up, with automatic switchover. Both of the power supplies are monitored.

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839:pt8, all system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally generated pilot tone is available for monitoring impedance on the loudspeaker lines. The IDA8SL Slave supports redundant network cabling as a redundant loop. The system can handle 256 priorities, for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements.

Main CharaCteriStiCS

•Public address and emergency sound system slave unit

•Fully digital with: 8 audio inputs and 8 audio outputs

•Two dedicated and monitored PDC-ports for firemen’s microphones

•2 dedicated audio in and outputs for back-up amplifiers

•Enhanced loudspeaker line surveillance for low-impedance installations

•Simultaneous control and routing of 48 audio channels over dedicated network

•Equipped as standard with RJ45 network cards for links up to 100 m

• Optional Fiberoptic cards for links up to 20 km

•9 supervised control inputs and 8 control outputs

•Ethernet interface for configuration, control, diagnostics and logging

•Digital storage for up to 4 hours of pre-recorded messages

• 4 message players

• EN54-16 certified

Page 19: ateis-PAVA2013-online.pdf

IDA8 system

19

inStallation noteS

IDA8 NETWORKABLE PAVA SYSTEM – Low Impedance Slave Unit

IDA8SL

Page 20: ateis-PAVA2013-online.pdf

20

IDA8 system

PartS inCluded

Quantities Components

1 IDA8SLxx Slave unit

1 Power cord

1 Set of mounting brackets for 19” rack

1 Set of connectors

1 Ateis Studio software GUI

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 48 W

Battery power supply

Voltage 18 - 26 VDC

Performance

Frequency response -3 dB @ 20 Hz and 20 kHz

Line inputs

Connector SPEAKON(electronically balanced)

Frequency response -3 dB @ 20 Hz and 20 kHz

S/N > 90 dBA

THD < 0,1% @ 1 kHz

Input sensitivity 770 mV

Input impedance 20 kOhm

Line outputs

Connector SPEAKON

S/N >-85 dBu

THD < 0,02% @ 1 kHz

Signal 770 m V

Output impedance < 300 Ohm

Loudspeaker lines in 4 x

Rated load resistance 8 Ohm (100 W) RMS

Rated load capacitance 250 nF (100 V)

Rated output power(per channel)

100 W (cont. at 40°C) 1500 W Piek

Loudspeaker lines out 4 x

Rated load resistance 8 Ohm (100 W) RMS

Rated output power(per channel)

100 W (cont. at 40°C) 1500 W Piek

Mechanical

Dimensions (H x W x D)

for 19” rack use, with brackets

88 x 483 x 300 mm

19” ‘in-front’ brackets 40 mm

Weight

IDA8SL 4.2 kg (9.25 lb)

Mounting 19”- rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Information

IDA8SL-C1 Slave with NET-C1 card

IDA8SL-C1-IO Slave with NET-C1 card & 4 audio inputs & 4 audio outputs

IDA8SL-C1-2I Slave with NET-C1 card& 8 audio inputs

IDA8SL-C1-2O Slave with NET-C1 card & 8 audio outputs

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

ControlS and indiCatorS

Front

• Status LEDs

• Zone LEDs

• Power LEDs

Rear

• Voltage selector

interConneCtionS

Rear

• Mains input

• Battery backup input

• 9 control inputs

• 8 control outputs

• Optional: 4 analogue audio mic/line inputs

• Optional: 4 analogue audio line inputs

• 2 system LOCAL-network connections

• 4 low-impedance amplifier in and outputs

• 1 connection for back-up amplifiers

• 2 monitored paging console inputs

• 2 connections for back-up amplifiers

IDA8 NETWORKABLE PAVA SYSTEM – Low Impedance Slave Unit

IDA8SL

Page 21: ateis-PAVA2013-online.pdf

21

IDA8 system

1. System fault

2. General fault

3. Bypass mode

4. Bypass monitoring

5. Global EVAC

6. EVAC indicators

7. Power

8. Network

9. FAULT indicators

1. Backup amplifier output

2. Bypass mode outputs

3. PDC-ports for secured paging consoles

4. Local network card

5. Zone 1 Speaker line output

6. Zone 1 Amplifier output

7. Zone 1 amplifier input

8. Backup amplifier input

9. 8 Contact outputs

10. 9 Contact inputs

11. 24 VDC slave output

12. 24 VDC back-up input

13. AC power socket

IDA8 NETWORKABLE PAVA SYSTEM – Low Impedance Slave Unit

IDA8SL

Page 22: ateis-PAVA2013-online.pdf

IDA8 system

22

ATEIS NET SECURED AUDIO NETWORK CARD

NET-CX

ATEÏS Net™ is a secured (monitored) audio network developed for fast and low-latency audio and data transport over a redundant copper (CAT-5) or fibreoptic network ring. ATEÏS Net™ has an open-architec-ture design and interfaces with remote devices such as paging consoles, audio break-in and break-out convertors and room controllers. It is best suited to medium to large-scale installations, such as shop¬ping malls, retail stores, train stations and airports.

ATEÏS Net™ secured audio network responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

funCtionS

ATEÏS Net™ is able to simultaneously transport 48 audio channels (32 bit, 48 kHz sampling rate) with a latency <1ms together with the necessary control data over a CAT-5 or fibreoptic dedicated network. For LOCAL and GLOBAL system networking, optional ATEÏS Net™ networking cards can be installed into the IDA8 Controller and Slave units. Thanks to its loop architecture, the ATEÏS Net™ audio network is fully redundant. If a problem (line open or shorted) occurs on a loop segment, it will be automatically isolated without affecting system functionality. One IDA8C Controller and up to 31 IDA8S Slaves can be connected together onto one LOCAL network. For systems of more than 32 units, or to link LOCAL networks, the GLOBAL network is used. Up to 32 IDA8C Controllers can be connected on the same GLOBAL network.

As network addresses are auto negotiated, network setup is very easy. Once programmed, the system will function independently without a PC having to be connected. IDA8C Controller units can be equipped with both LOCAL and GLOBAL network cards the communication network to be expanded up to 32 x 32 nodes.

NET-C1 cards (RJ45 to RJ45) are suitable for installation distances of up to 100m between Controller and Slave and/or Slave and Slave. For longer installation distances, optional NET-C2, C3 or C4 can be used to extend distances up to 2 km between units in multi-mode or 20 km in single-mode.

Main CharaCteriStiCS

• Ateis Net™ audio and data secured network

• Local-net & Global-net

• 32 x 32 - nodes in a combined network

• Low-latency <1ms

• 48-audio channels

• Redundant loop architecture

• 32 bit, 48 kHz sampling

• CAT-5 for up to 100 m

• Fibreoptic dual-mode for up to 2 km

• Fibreoptic single-mode for up to 20 km

• Dedicated network

• EN54-16 certified

NET-C1, 2x RJ45 Port A & Port B NET-C2, 1x RJ45 Port B & 1x fibre Port A

NET-C3, 2x fibre Port A & Port B

NET-C4, 1x fibre Port B & 1x RJ45 Port A

NotePort A = network INPort B = network OUT

Page 23: ateis-PAVA2013-online.pdf

IDA8 system

23

PartS inCluded

Quantities Components

1Ateis Net™ secured audio network card

1Set of interconnecting ribbon cables

1 Set of mounting pillars

teChniCal SPeCifiCationS

Electrical

Battery power supply

Voltage Internal multi-power socket

Power consumption 5 W

Audio transport 48 channels

Performance

Frequency response -3 dB @ 20 Hz and 22 kHz

Sampling rate 32 bit / 48 kHz

Latency < 1 ms

Integrity assurance Watchdog

Indicators

LED Network active

LED Network present

Mechanical

Dimensions (H x W x D) 18 x 100 x 150 mm

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering information

NET-C1, RJ45(A)/RJ45(B) (supplied as standard with IDA8 models)

NET-C2, ST Multi-mode Fibre (A)/RJ45(B) (Surcharge)

NET-C3, ST Multi-mode Fibre(A)/(B) (Surcharge)

NET-C4, RJ45(A)/ST Multi-mode Fibre(B) (Surcharge)

NET-C3S, ST Single-mode Fibre(A)/(B) (Surcharge)

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839:pt8, all IDA8 system components and peripherals on the ATEÏS Net™ secured audio network are monitored and reports stored in the IDA8C system controller. The controller monitors the status of all the equipment in the system, reports status changes and stores fault messages for recall either on the controller front-panel display or through the ATEÏS Studio PC-based software.

inStallation noteS

ATEIS NET SECURED AUDIO NETWORK CARD

NET-CX

ControlS and indiCatorS

Front

• Data running indicator

• Net-work present indicator

interConneCtionS

Front

•Two system network connections either CAT5 or Fiber-optic or a combination

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe Certification CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

Page 24: ateis-PAVA2013-online.pdf

ATEÏS Studio

24

INTEGRATED OPERATION SOFTWARE

ATEÏS Studio

ATEÏS Studio is a user-friendly graphic user interface designed for intuitive system setup. The PC-based software allows hardware updating, full system configuration and generates the user interface for day-to-day system operation.

graPhiCal uSer interfaCe

ATEÏS Studio allows complete PAVA/audio systems incorporating a range of devices to be configured, monitored and controlled centrally from a single user interface. ATEÏS Studio supports all IP-based products within the ATEÏS product family such as IDA8, LAP-AS and ECS. The software enables a comprehensive overview of the system and its virtual connections and also offers control and configuration for power amplifiers, paging consoles and remote controllers such as PSS-AS, CD16-AS and URC-AS devices.

diagnoSting

ATEÏS Studio monitors, controls, logs and reports a range of events. The whole system configuration preset can be stored and reloaded at the press of a button, depending on application. Users can tailor design elements of the graphic user interface or control panels, as well as program automatic sequences of events and create different levels of user access for security and rights management.

Building

ATEÏS Studio provides a complete set of tools and building blocks for real-time control, monitoring and design of an audio system or Voice Evacuation system from paging console to loudspeaker. Detailed information such as signal levels, loudspeaker impedance, pre-recorded messages, amplifier conditions and other parameters can be monitored in real-time.

A comprehensive library of tools, control and monitoring elements is provided along with the GUI, including items such as volume control faders, metering, high-level EQ, compression, limiting, auto-gain, noise sensing, mixing, shortcut buttons and display elements. Element behaviour can be fully tailored to suit each application. Built-in file transfer software transfers both data and audio files from the PC to the network controller.

Configuration Software

• Runs on Windows

• Assignable access levels with rights management

• All system and unit parameters can be configured

• Easy navigation

diagnoStiC and logging Software

• Call, fault and general event logging

• On-line logging function

• Historical logging

• Event display priority can be changed

• Password-protected

file tranSfer Software

• PC-based application

• Supplied together with the network controller

• Creation of message sets

• Off-line configuration

Page 25: ateis-PAVA2013-online.pdf

ATEÏS Studio

25

aCCeSS levelS

Additional security can be added to the software with password-protected layers according to EN 54-16. Multiple users can be created and assigned, each with a unique password and access to specific layers of the GUI. This creates a control surface specific to the needs of system designers and operators at multiple levels.

INTEGRATED OPERATION SOFTWARE

ATEÏS Studio

Page 26: ateis-PAVA2013-online.pdf

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

ATEÏS Europe B.V. Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDS

Phone: +31 (0)10 2088690 - Fax: +31 (0)10 [email protected]

ATEÏ

S re

serv

e th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otic

eHE

LPRO

D.CO

M -

Pro

duct

pic

ture

s, R

ober

t Pee

k Fo

togr

afie

- F

otol

ia

DIVA8S G2

Compact PAVA SystemSlave Unit

Page 27: ateis-PAVA2013-online.pdf

DIVA8 System

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

LoudspeakersDIVA8MG2

Compact PAVA System Master Unit

DIVA8 system is a compact PAVA

solution specifically designed for

small to medium-scale installations.

It has all the essential functionality

to comply with EN 54 requirements

for Voice Alarm, including full sys-

tem monitoring, loudspeaker line

impedance surveillance, micro-

phone surveillance and monitored

interfacing with remote devices.

DIVA8 responds to Public Address

and Voice Alarm requirements

as stated in EN54-16, ISO 7240-

16 and BS5839/8, with specific

attributes for compliance in large

installations.

Page 28: ateis-PAVA2013-online.pdf

28

DIVA8 system

COMPACT PAVA SYSTEM – MASTER UNIT

DIVA8M G2

DIVA8 system is a compact PAVA solution specifically designed for small to medium-scale installations. It has all the essential functionality to comply with EN 54 requirements for Voice Alarm, including full system monitoring, loudspeaker line impedance surveillance, microphone surveillance and monitored interfacing with remote devices.

DIVA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ConneCtivity

The DIVA8M G2 Master unit provides enhanced digital audio processing (DSP), a digital message player, a fully monitored fireman’s microphone, amplifier monitoring with switchover to backups and loudspeaker line monitoring for 16 audio lines (8 lines A/B). It can process and route one PSS-G2, CD8-G2 or CD16-G2 microphone console or up to eight cascaded PSM8-V3 paging microphones, along with two 0dB audio inputs and one mic/line input into two different channels (music + voice) using configurable priorities. The DIVA8 system utilises two external amplifier channels with a maximum capacity of 1000 W each.

Pre-ProCeSSing

All audio inputs feature contact and VOX activation and each input is fitted with volume controls and equalisers. Up to 45 minutes of digital messaging can be stored in the unit. These are stored as WAV files and uploaded directly from a PC into the DIVA8M G2. Up to two messages can be played simultaneously in different zones for phased evacuation.

interfaCing

DIVA8M G2 has nine monitored alarm inputs which can be individually programmed for specific message/input routing to all or selected channels. Each DIVA8 system module has eight output zones with A/B wiring and each zone can be routed manually or automatically to one of the system’s audio channels (music or voice). The number of zones can be extended up to 128 A/B zones with the addition of DIVA8S G2 Slave units (up to a maximum of 15 slave units). The music source can be selected directly from the front panel and switched into each zone separately and a rear-panel RS232 port allows third-party control and interfacing.

Main CharaCteriStiCS

•DIVA8 System Master Public address and emergency sound system control unit

•8-zone system controller with individual volume controls per channel

• 2 channel audio distribution for Paging and BGM

• Combined back-up amplifier function

• 5 audio inputs

• 2 x 1000 Watt maximum load

•Enhanced loudspeaker line surveillance for A/B zoned installations

• 9 monitored control inputs

• 8 logic control inputs

•Ethernet interface for configuration, control, diagnostics and logging

• Third party control

•Digital storage for up to 45 minutes of pre-re-corded messaging

• Stores the last 999 fault events

• 3,5” colour touch-screen

• EN54-16 certified

Page 29: ateis-PAVA2013-online.pdf

DIVA8 system

29

redundanCy

In case of Evacuation, the amplifier music channel can be used as a second alarm channel. Each DIVA8 system requires only one 2-channel amplifier (one channel for music, one for voice). The music amplifier will also act as a backup amplifier in case of voice amplifier failure. Each channel can handle up to 1000W audio power (at 100V).

From the DIVA8M G2 front panel the user can manually route the fireman’s microphone signal and three digital messages into selected zones, adjust the audio level and switch (ON/OFF) the music in each zone separately. In case of evacuation, the zone attenuators are automatically bypassed. One output contact per zone can be activated each time the zone is occupied with a source that has higher priority than the music (alarm or microphone paging).

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839/8, all DIVA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally-generated pilot tone is available for monitoring impedance on the loudspeaker lines. The master unit monitors the status of all the equipment in the system, reports status changes and stores the last 999 fault messages in the system. This log can be accessed on the master unit display or on a PC using the DIVA8 control software.

DIVA8 system units operate either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored.

inStallation noteSinterConneCtionS

COMPACT PAVA SYSTEM – MASTER UNIT

DIVA8M G2

Page 30: ateis-PAVA2013-online.pdf

30

DIVA8 system

PartS inCluded

Quantities Components

1 DIVA8M G2 Master unit

1 Fireman’s microphone

1 Power cord

1 Set of connectors

1 Set of 19” rackmount brackets

1 DIVA8-system software

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 48 W

Battery power supply

Voltage 18 - 26 VDC

Performance

Frequency response -3 dB @ 20 Hz and 20 kHz

Audio Line inputs 2 x

Connector 2x2 RCA (un-balanced)

Frequency response -3 dB @ 20 Hz and 20 kHz

S/N >76 dB (Line-level) >78 dB (Mic-level)

THD < 0,02% @ 1 kHz

Input range 770 mV (0 dBu to -60 DBU)

Input impedance 10 kohm

Fireman’s microphone 1 x

Connector 5-pin locking-DIN

Frequency response -3 dB @ 200 Hz and 10 kHz

S/N >70 dBu

THD < 1% @ 1 kHz

Signal -40 to -30 dBu

Output impedance 10 kohm

Monitor loudspeaker

Frequency response -3 dB @ 200 Hz and 10 kHz

S/N >70 dBu

THD < 5% @ 1 kHz @ 8ohm

Signal 16 dBu

Amplifier lines in 2 x 100 V

Max rated output power 1000 W (cont. at 40°C)

Frequency response -3 dB @ 50 Hz and 18 kHz

Input level 16 dBu

Loudspeaker lines out 16 x

Rated load resistance 100 ohm (100 V)

Rated power 100 W (cont. at 40°C)

Mechanical

Dimensions (H x W x D)

for 19” rack use, with brackets

88 x 483 x 338 mm

Weight

DIVA8M G2 7.5 kg (16,5 lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Ordering information

DIVA8M G2 Master unit

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

ControlS and indiCatorS

Front

• 3,5” full colour touch-screen LCD display

• Zone selection buttons

• EVAC-start

• Fireman’s microphone

• Status indicators

Rear

• Voltage selector

interConneCtionS

Front

• Fireman microphone

Rear

• Mains input

• Battery backup input

• 8 EVAC inputs

• 9 control inputs

• 2 fault inputs

• 8 control outputs

• 1 remote Fireman’s mic input

• 4 analogue line audio inputs

• Ethernet connection

• 8 zone 100 Volt outputs (A+B)

• 1 monitored paging console input

COMPACT PAVA SYSTEM – MASTER UNIT

DIVA8M G2

Page 31: ateis-PAVA2013-online.pdf

31

DIVA8 system

1. Global EVAC

2. Power indicator

3. Navigation buttons

4. RESET button

5. 3.5” touch-screen

6. Navigation buttons

7. Zone status indicators

8. Fireman’s microphone on hook

9. All Call & Cancel button

10. ALERT & TEST button

11. BGM control and selection buttons

12. System status indicators

13. Zone attenuator rotary knobs

14. Zone selection buttons

15. Monitor loudspeaker (behind fireman’s mic) (Audible warning)

1. Control inputs

2. Evacuation inputs

3. RS232 connector

4. Ethernet connector

5. Power MAINS

6. Logic outputs

7. EVAC & FAULT contacts

8. Amplifier I/O

9. 100 V signal links

10. Speaker zone outputs (A+B lines)

11. Paging console input

12. Master – Slave link

13. Remote Ext. connector

14. Mic/Line input

15. Music inputs

16. External fireman’s mic Input

17. 24 VDC backup supply input

COMPACT PAVA SYSTEM – MASTER UNIT

DIVA8M G2

Page 32: ateis-PAVA2013-online.pdf

32

DIVA8 system

COMPACT PAVA SYSTEM – SLAVE UNIT

DIVA8S G2

DIVA8 system is a compact PAVA solution specifically designed for small to medium-scale installations. It has all the essential functionality to comply with EN 54 requirements for Voice Alarm, including full system monitoring, loudspeaker line impedance surveillance, microphone surveillance and monitored interfacing with remote devices.

DIVA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ConneCtivity

The DIVA8S G2 Slave unit is an extension unit for the DIVA8M G2 Master. It increases the number of paging zones by 8 zones for each slave unit added in the system. Up to 15 slave units can be added per DIVA8 system and must be used in conjunction with the DIVA8M G2 Master. A complete DIVA8 system provides up to 128 zones (A/B). Slave units are linked to the system master via shielded CAT-5 cable (max. length 100m).

The DIVA8S G2 Slave handles the same 1000 W power capacity as the master unit (at 100V) on each amplifier channel (music + voice). Each zone can be routed manually or automatically to either channel. For maximum flexibility connected amplifiers can distribute their power across multiple slaves or additional amplifier channels can be added to the system to assist where more output power is needed. The 100 V amplifier signal is simply linked to the slaves to create a 100 V signal bus.

interfaCing

DIVA8S G2 extends the number of input and output contacts available in the system. It includes nine alarm inputs triggered either by dry contact or relay (software-selectable), eight logic contact inputs, two external fault contact inputs and eight contact outputs.

redundanCy

In case of Evacuation, the amplifier music channel can be used as a second alarm channel. Each DIVA8 system requires only one 2-channel amplifier (one channel for music, one for voice). The music amplifier will also act as a backup amplifier in case of voice amplifier failure. Each channel can handle up to 1000 W audio power (at 100 V).

From the DIVA8M G2 Master unit front panel the user can manually route the fireman’s microphone signal and three digital messages into selected zones, adjust the audio level and switch (ON/OFF) the music in each zone separately. In case of evacuation, the zone attenuators are automatically bypassed. One output contact per zone can be activated each time the zone is occupied with a source that has higher priority than the music (alarm or microphone paging).

Main CharaCteriStiCS

•DIVA8-System Master Public address and emergency sound system slave unit

• 2 channel audio distribution for Paging and BGM

• combined back-up amplifier function

• 5 audio inputs

• 2 x 1000 Watt amplifier inputs

•Enhanced loudspeaker line surveillance for A/B-zoned installations

• 9 monitored control inputs

• 8 logic control inputs

•Ethernet interface for configuration, control, diagnostics and logging

• EN54-16 certified

Page 33: ateis-PAVA2013-online.pdf

DIVA8 system

33

SeCurity

In accordance with EN54-16, ISO 7240-16 and BS5839/8, all DIVA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally-generated pilot tone is available for monitoring impedance on the loudspeaker lines. The master unit monitors the status of all the equipment in the system, reports status changes and stores the last 999 fault messages in the system. This log can be accessed on the master unit display or on a PC using the DIVA8 control software.

DIVA8 system units operate either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored.

interConneCtionS

inStallation noteS

1000 Watt System 3 x 1000 Watt System

Single amplifier set Multiple amplifier sets

1000 Watt System 3 x 1000 Watt System

Single amplifier with single back-up Multiple amplifier with single back-up

COMPACT PAVA SYSTEM – SLAVE UNIT

DIVA8S G2

Page 34: ateis-PAVA2013-online.pdf

34

DIVA8 system

PartS inCluded

Quantities Components

1 DIVA8SG2 Slave unit

1 Power cord

1 Set of connectors

1 Set of 19” mounting brackets

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 35 W

Battery power supply

Voltage 18 - 26 VDC

Performance

Frequency response -3 dB @ 20 Hz and 20 kHz

Amplifier lines in 2 x 100 V

Max rated output power 1000 W (cont. at 40°C)

Frequency response -3 dB @ 50 Hz and 18 kHz

Input level 16 dBu

Loudspeaker lines out 16 x

Rated load resistance 100 ohm (100 V)

Rated power 100 W (cont. at 40°C)

Mechanical

Dimensions (H x W x D)

for 19” rack use, with brackets

44 x 483 x 277 mm

Weight

DIVA8SG2 3.9 kg (8.6 lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Information

DIVA8SG2 Slave unit

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

ControlS and indiCatorS

Front

• Zone selection buttons

• Zone status indicators

interConneCtionS

Rear

• AC Mains input

• 24 V DC Battery backup input

• 9 EVAC inputs

• 8 control inputs

• 2 fault inputs

• 8 control outputs

• Master to Slave link

• 8 zone 100 Volt outputs (A+B)

COMPACT PAVA SYSTEM – SLAVE UNIT

DIVA8S G2

Page 35: ateis-PAVA2013-online.pdf

35

DIVA8 system

1. Power indicator

2. Zone status indicators

3. Zone selection buttons

1. Control inputs

2. Evacuation inputs

3. Master – Slave link

4. 24 V DC backup input

5. Speaker zone outputs (A+B lines)

6. 100 V signal links

7. Terminator switch (Last slave in the line)

8. Slave-ID rotary switch

9. Logic outputs

10. AC power input

COMPACT PAVA SYSTEM – SLAVE UNIT

DIVA8S G2

Page 36: ateis-PAVA2013-online.pdf

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

ATEÏS Europe B.V. Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDS

Phone: +31 (0)10 2088690 - Fax: +31 (0)10 [email protected]

ATEÏ

S re

serv

e th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otic

eHE

LPRO

D.CO

M -

Pro

duct

pic

ture

s, R

ober

t Pee

k Fo

togr

afie

- F

otol

ia

BPA

Basic Power Amplif iers

SPA

Sinewave Power Amplif iers

SONAES

Charger and Monitoring Unit

Page 37: ateis-PAVA2013-online.pdf

Amplifiersand battery charger

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

LoudspeakersDPAfourDigital Power Amplif iers

DPAfour (Digital Power Amplifier),

BPA (Sinewave Power Amplifier)

and BPA (Basic Power Amplifier)

are designed for public address or

voice alarm system application.

They were specifically developed to

meet the requirements of EN54-16

and can therefore also be used as

part of fire detection and fire alarm

systems.

Page 38: ateis-PAVA2013-online.pdf

Ampl i f ie rs

38

DIGITAL POWER AMPLIFIERS

DPAfour

The DPAfour is a 2U 19” rack mountable, 4-channel class-D power amplifier, transformer isolated for 100 V, 70 V, 50 V and 4 Ohm distributed loudspeaker systems. There are two models in the DPAfour range: DPAfour125 rated at 4 x 125 W and DPAfour250 at 4 x 250 W.

Each channel can deliver up to 250 W when used as separate channel or can be bridged to deliver higher power. The amplifier has a dual-voltage mains supply 110/230V AC and a 24 V DC battery back-up input which allows it to be used in combination with a battery backup system for maximum availability and reliability in an emergency evacuation system. DPAfour amplifiers have short-to-ground, short-circuit detection and line-impedance surveillance up to 5% deviation using the DIVA8 or IDA8 systems for loudspeaker-line surveillance. They support both single-spure and redundant loop cabling (A/B).

The DPAfour amplifiers have a single power supply that shares redundancy via the SONAES battery charger and redundant power supply. Using an intelligent switching construction, one SONAES can serve up to seven DPAfour amplifiers and three IDA8 units, or one DIVA8 with nine slaves. In case an internal power supply fails, the amplifier modules will automatically switch over to the backup power supply provided by the SONAES, leaving the batteries untouched and available for emergency cases.

Main CharaCteriStiCS

• 4 audio outputs (100/70/50 V / 4 Ohm selectable)

• Fault reporting outputs

• Four audio inputs with gain

•Advanced audio processing for each amplifier channel using DIVA8 or IDA8 systems

•Supervision of the amplifiers through DIVA8 or IDA8 systems

•Back up amplifier switching throught DIVA8 or IDA8 sys-tems

•Loudspeaker line and loudspeaker impedance surveil-lance through DIVA8 or IDA8 systems

• Output bridging for higher power

ControlS and indiCatorS

• LED VU metering

•Status indicators for: Signal, Clip, Mains, Battery, Channel fault and General fault

interConneCtionS

Rear

• Rotary volume control

• Mains switch

• Mains input

• Battery backup input

• Four line inputs

•100 V, 70 V, 50 V or 4 ohm outputs (for each amplifier channel)

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

DIVA & DPA

Wiring example

with DPA Ch 1&2

bridged*

* If DPA channels are bridged, gain settings

should be set at equal level for both channel 1&2 and/

or 3&4

IDA8 & DPA

Wiring example

Page 39: ateis-PAVA2013-online.pdf

Ampl i f ie rs

39

PartS inCluded

Quantities Components

1 DPA xxxx Digital Power Amplifier

1 Power cord

1 Set of connectors

1 Set of feet

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption** standby - idle* - Pmax

DPA4125 1 W – 38 W – 600 W

DPA4250 1 W – 44 W – 1169 W

**(Total Mains-power consumption @ 230 VAC)

*(Alarm cycle + 10 V pilot-tone @ 24 VDC)

Battery power supply

Voltage 19-30 VDC

Power consumption*** standby - idle* - Imax

DPA4125 0.03 A – 1.45 A – 22.5 A

DPA4250 0.03 A – 1.65 A – 43.85 A

***(Total DC-current @ 24 VDC)

*(Alarm cycle + 10 V pilot-tone @ 24 VDC)

Line inputs 4 x (One per channel)

Connector 3-pin phoenix

Frequency response +/-3 dB @ 50 Hz and 20 kHz

S/N > 90 dB

THD < 0,1% @ 1 kHz

Input sensitivity 770 mV

Input impedance 20 kOhm

Loudspeakers outputs DPA4125

Rated load resistance 80 ohm (100 V)

Rated load capacitance 62,5 nF (100 V)

Rated output power(per channel) 125 W (cont. at 40°C)

Two channels bridged 250 W (cont. at 40°C)

Loudspeakers outputs DPA4250

Rated load resistance 40 ohm (100 V)

Rated load capacitance 120 nF (100 V)

Rated output power(per channel) 250 W (cont. at 40°C)

Two channels bridged 500 W (cont. at 40°C)

Frequency response 40 Hz to 20 kHz(-3 dB)

S/N >90 dB (no pilot tone)

Crosstalk <70 dB at nominal load for 1 kHz

Distortion <0,1% (@ 1 kHz) @ -10dB of rated outputpower

Mechanical

Dimensions (H x W X D)

19” rack use, with brackets 88,5 x 483 x 370 mm

Weight

DPA 4125 14 kg (31 lb)

DPA 4250 18 kg (40 lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Informations

DPAfour125, Digital Power Amplifier

DPAfour250, Digital Power Amplifier

1. AC Power inlet

2. AC/DC Fuse

3. Power switch

4. 24 VDC backup

5. Channel 1-4 audio outputs

6. Channel 1-4 audio inputs

7. General fault output contact

8. Service request output contact

9. Lamp test input contact

10. Spare input contact

DIGITAL POWER AMPLIFIERS

DPAfour

Page 40: ateis-PAVA2013-online.pdf

Ampl i f ie rs

40

SINEWAVE POWER AMPLIFIERS

There are two types of power amplifier units in the SPA-PAVA product range. The overall power rating is 2x120 or 2x240 watts. The power amplifiers can be set to 100 V, 70 V and 8 Ohm output tappings. They have short-to-ground, short-circuit detection and line-impedance surveillance up to 5% deviation using the DIVA8 and IDA8 range of products for loudspeaker-line surveillance.

They support both single-spure and redundant loop cabling (A/B). The amplifiers have a changeover facility for spare power amplifier switching. Both features are facilitated by the DIVA8 and IDA8 controllers and slaves. The amplifiers have a 24 VDC back-up supply input.

funCtionS

The power amplifiers receive line-level input signals from the DIVA8 and IDA8 controllers and slaves. The display shows the VU-meter reading, when the EN54-16 default switch is inhibited.

Main CharaCteriStiCS

• 2 audio outputs (100/70 / 8 Ohm outputs selectable)

• Fault reporting outputs

• Two audio inputs with gain-set

•Supervision of the amplifiers using DIVA8 or IDA8 controllers

•Advanced audio processing for each amplifier channel using DIVA8 or IDA8 systems

•Amplifier supervision and spare amplifier switching through DIVA8 or IDA8 systems

•Loudspeaker line and loudspeaker supervision through DIVA8 or IDA8 systems

ControlS and indiCatorS

• LED VU metering

•Status indicators for: Overload, Temperature control, Battery and Mains

interConneCtionS

Rear

• Rotary volume control

• Mains switch

• Mains input

• Battery backup input

• Two line inputs

•100 V, 70 V, and 8 ohm outputs (for each amplifier channel)

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

DIVA8

IDA8 8

SPA

Page 41: ateis-PAVA2013-online.pdf

Ampl i f ie rs

41

PartS inCluded

Quantities Components

1 SPA 2xxx Sinewave Power Amplifier

1 Power cord

1 Set of mounting brackets for 19” rack

1 Set of connectors

1 Set of feet

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 230 VAC ±10%, 50/60 Hz

Power consumption** standby - idle* - Pmax

SPA 2120 28 W – 150 W – 322 W

SPA 2240 64 W – 287 W – 655 W

* Idle: Measured with 10 Volt surveillance tone on the output.

**(Total Mains-power consumption)

Battery power supply

Voltage 21-28 VDC

Power consumption** standby - idle* - Imax

SPA 2120 0.25 A – 2.9 A – 6.4 A

SPA 2240 0.30 A – 5.47 A – 12.3 A

**(Per ch. @ 28 VDC)

*(Alarm cycle + 10 V pilot-tone @ 28 VDC)

Line inputs 2 x (One per channel)

Connector(electronically balanced)

3-pin XLR and 3-pin phoenix

Frequency response +/-3 dB @ 40 Hz and 20 kHz

S/N > 90 dBA

THD < 1% @ 1 kHz

Input range -6 dBV to 6 dBV / 770mV

Input impedance 22 kOhm

Loudspeaker outputs SPA2120

Rated load resistance 100 Ohm (100 V); 50 Ohm (70 V)

Rated load capacitance 60 nF (100 V); 125 nF (70 V)

Rated output power(per channel) 120 W (cont. at 40°C)

Loudspeaker outputs SPA2240

Rated load resistance 40 Ohm (100 V); 20 Ohm (70 V)

Rated load capacitance 125 nF (100 V); 250 nF (70 V)

Rated output power(per channel) 240 W (cont. at 40°C)

Frequency response 40 Hz to 20 kHz(-3 dB)

S/N > 90 dB (no pilot tone)

Crosstalk < 80 dB at nominal load for 1 kHz

Distortion < 1% (@ 1 kHz) @ -10dB of rated output

SINEWAVE POWER AMPLIFIERS

SPA

Mechanical

Dimensions (H x W x D)

for tabletop use, with feet 92 x 440 x 305 mm

for 19” rack use, with brackets 88 x 483 x 305 mm

Weight

SPA 2120 12,3 kg (27,1 lb)

SPA 2240 18,5 kg (40,8 lb)

Mounting Standalone or 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering information

SPA 2120

SPA 2240

1. AC Power inlet

2. AC/DC Fuse

3. Power switch

4. Configuration switches for EN54-16 compliances

5. Channel 1/2 24 VDC battery backup connector

6. Fault contact

7. Channel 1 output

8. Channel 1 input

9. Channel 2 output

10. Channel 2 input

Page 42: ateis-PAVA2013-online.pdf

Ampl i f ie rs

42

BASIC POWER AMPLIFIERS

BPA

The BPA is a 2U 19” rack-mountable, 2-channel amplifier, transformer isolated for 100 V, 70 V and 8 Ohm distributed loudspeaker systems. There are three models in the BPA range: BPA2120 at 2 x 120 W, BPA2240 at 2 x 240 W and BPA2480 at 2 x 480 W.

The BPA amplifier has a 230 V AC mains supply input and a 24 V DC battery back-up input which allows it to be used in combination with a battery backup system for maximum availability and reliability in an emergency evacuation system. BPA amplifiers have short-to-ground, short-circuit detection and line-impedance surveillance up to 5% deviation using the DIVA8 or IDA8 systems for loudspeaker-line surveillance. They support both single-spure and redundant loop cabling (A/B) and have a switchover facility that automatically reroutes power to a backup amplifier (if present) via the SONAES charger in the event of failure. BPA amplifiers have a rear-panel selector switch for amplifier monitoring according to EN 54-16.

Main CharaCteriStiCS

•2 audio outputs for BPA2120, 2240 and 2480(100 V / 70 V / 50 V selectable outputs)

• Fault reporting outputs

• Two audio inputs with gain-set

• Supervision of amplifiers through DIVA8 or IDA8 systems

•Advanced audio processing for each amplifier channel through DIVA8 or IDA8 systems

•Amplifier supervision and spare amplifier switching through DIVA8 and IDA8 systems

•Louspeaker line and loudspeaker supervision through DIVA8 and IDA8 systems

ControlS and indiCatorS

• LED VU metering

•Status indicators for: Overload, Temperature control, Battery and Mains

interConneCtionS

Rear

• Rotary volume control at the rear of the device

• Mains switch at the rear of the device

• Mains input

• Battery backup input

• Two line inputs

100 V, 70 V and 8 ohm outputs (for each amplifier channel)

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

DIVA8

IDA8 8

Page 43: ateis-PAVA2013-online.pdf

Ampl i f ie rs

43

PartS inCluded

Quantities Components

1 BPA 2xxx Basic Power Amplifierr

1 Power cord

1 Set of mounting brackets for 19” rack

1 Set of connectors

1 Set of feet

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 230 VAC ±10%, 50/60 Hz

Power consumption** standby - idle* - Pmax

BPA 2120 16 W – 74 W – 154 W

BPA 2240 28 W – 150 W – 322 W

BPA 2480 64 W – 287 W – 655 W

* Idle: Measured with 10 Volt surveillance tone on the output.

**(Total Mains-power consumption)

Battery power supply

Voltage 21-28 VDC

Power consumption** standby - idle* - Imax

BPA 2120 0.19 A – 1.5 A – 3.2 A

BPA 2240 0.25 A – 2.9 A – 6.4 A

BPA 2480 0.30 A – 5.47 A – 12.3 A

**(Per ch. @ 28 VDC)

*(Alarm cycle + 10 V pilot-tone @ 28 VDC)

Line inputs 2 x (One per channel)8 x for BPA8060

Connector 3-pin XLR and 3-pin phoenix (electronically balanced)

Frequency response +/-3 dB @ 40 Hz and 20 kHz

S/N >90 dBA

THD <1% @ 1 kHz

Input range -6 dBV to 6 dBV / 770mV

Input impedance 22 kOhm

Loudspeakers outputs BPA8060

Rated load resistance 160 ohm (100 V); 80 ohm (70 V)

Rated load capacitance 30 nF (100 V); 60 nF (70 V)

Rated output power(per channel)

60 W (1 min. at 40°C) 30 W (cont. at 40°C)

Loudspeakers outputs BPA2120

Rated load resistance 100 ohm (100 V); 50 ohm (70 V)

Rated load capacitance 60 nF (100 V); 125 nF (70 V)

Rated output power(per channel)

120 W (1 min. at 40°C) 60 W (cont. at 40°C)

Loudspeakers outputs BPA2240

Rated load resistance 40 ohm (100 V); 20 ohm (70 V)

Rated load capacitance 125 nF (100 V); 250 nF (70 V)

Rated output power(per channel)

240 W (1 min. at 40°C) 120 W (cont. at 40°C)

Loudspeakers outputs BPA2480

Rated load resistance 20 ohm (100 V); 10 ohm (70 V)

Rated load capacitance 250 nF (100 V); 500 nF (70 V)

Rated output power(per channel)

480 W (1 min. at 40°C) 240 W (cont. at 40°C)

Frequency response 120 Hz to 20 kHz (-3 dB)

S/N > 90 dB (no pilot tone)

Crosstalk < 80 dB at nominal load for 1 kHz

Distortion < 1% (@ 1 kHz) @ -10dB of rated output

BASIC POWER AMPLIFIERS

BPA

Mechanical

Dimensions (H x W x D)

for tabletop use, with feet

92 x 440 x 305 mm

for 19” rack use, with brackets

88 x 483 x 305 mm

Weight

BPA 2120 10,6 kg (23,3 lb)

BPA 2240 12,3 kg (27,1 lb)

BPA 2480 18,5 kg (4,8 lb)

Mounting Standalone or 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Informations

BPA 2120 2 x 120 W

BPA 2240 2 x 240 W

BPA 2480 2 x 480 W

1. AC Power inlet

2. AC/DC Fuse

3. Power switch

4. Configuration switches for EN54-16 compliances

5. Channel 1/2 24 VDC battery backup connector

6. Fault contact

7. Channel 1 output

8. Channel 1 input

9. Channel 2 output

10. Channel 2 input

Page 44: ateis-PAVA2013-online.pdf

Bat ter y Charger

44

CHARGER AND MONITORING UNIT - EN 54-4

SONAES

The SONEAS series of battery chargers (24 Vdc) are intended for a Voice Alarm System. The battery chargers are microprocessor based devices that have been designed to charge lead-acid batteries (back-up batteries connected to the Voice Alarm System) and, simultaneously, to provide power to auxiliary devices such as the DIVA8 and IDA8 system controllers

The SONEAS battery chargers, which are fully compliant with EN54-4, offers a maximum charge current of 6 or 12 A. The battery charger is two rack units high, and has to be installed in a 19” rack. Maximum battery capacity: 225 AH.

overview

To find the right power back-up system for your needs, you will need to determine the exact conditions under which you will be utilizing a back-up system. Determining the amount of battery back-up you need for a system is not as simple as some other applications. Public address systems do not draw a constant current. The standard defines a standby time and an evacuation time. In this case, it is important to pick a battery back-up that can supply the minimum amount of power needed for a set amount of time. ATEIS can provide you with a battery calculator program to determine the exact capacity.

regular ProCedure aS followS:

Main CharaCteriStiCS

Soneas 6/40

• 2U-rackmount charger

• 3 Auxiliary outputs, max. 5 Amp combined load

• 2 Main outputs, max. 40 Amp combined load

• Battery capacity: 85 AH to 225 AH

Soneas 12/150

• 2U-rack-frame charger

• 3 Auxilairy outputs, max. 5 Amp combined load

• 6 Main outputs, max. 20A mp/ch

• Battery capacity: 85 AH to 225 AH

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0333 (AFNOR)

Immunity according to EN50103-4

PAVA EN54-4 certified 2010

1. Determine the standby current of the system. This information is available in

the voice alarm system manual.

2. Multiply the standby current by the standby time that the local standards call

for. Typically this is 24 hours.

3. Compare this value to the 24 hour discharge capacity of the battery.

4. Determine the evacuation current of the system. This information is available

in the voice alarm system manual.

5. Multiply the evacuation current by the time that the local standards call for.

Typically this is one hour or 30 minutes.

6. Compare this value to the 30 minute or 60 minute hour discharge capacity

of the battery.

PartS inCluded

Quantities Components

1 SONEAS 6/40A or SONEAS 12/150A

1 Power cord

1 Set of connectors

Ordering Information

SONEAS 6/40

SONEAS 12/150

Page 45: ateis-PAVA2013-online.pdf

Bat ter y Charger

45

teChniCal SPeCifiCationS

Electrical

Mains power supply

Voltage 115 or 230 VAC ±15%, 50/60 Hz

Power consumption 380 W at Full load

Battery power supply

Voltage 24 VDC

Maximum charging current

Soneas 6/40 6 Amp

Soneas 12/150 12 Amp

Ouputs

Main for amplifiers

Soneas 6/40 2 x 20 A

Soneas 12/150 6 x 40 A

Auxiallairy for controllers 3 x

Maximum current 5 Amp

Batteries 4x 12 VDC, 85 to 225AH

Brands

Yuasa NPL seriesPowersonic GB seriesABT TM seriesEnersys VE seriesEffekta BTL seriesLong GB series

Mechanical

Dimensions (H x W X D)

19” rack use, with brackets 44 x 483 x 310 mm

Weight

SONEAS 6/40 4.9 kg (10.8 lb)

SONEAS 12/150 6 kg (13 lb)

Mounting 19”-rackmount

Colour RAL7016

Environmental

Operating temperature -5 ºC to +45 ºC

Storage temperature -25 ºC to +85 ºC

Relative humidity 20% to 95%

Air pressure 600 to 1100 h Pa

1. Main power socket

2. Auxiliary output terminals

3. Temperature sensor

4. Main output terminals

5. Output contacts

6. Battery terminal

CHARGER AND MONITORING UNIT - EN 54-4

SONAES

inStallation noteS for SonaeS 6/40

rear layout of SonaeS 12/150

Soneas 6/40

Soneas 12/150

Page 46: ateis-PAVA2013-online.pdf

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

ATEÏS Europe B.V. Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDS

Phone: +31 (0)10 2088690 - Fax: +31 (0)10 [email protected]

ATEÏ

S re

serv

e th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otic

eHE

LPRO

D.CO

M -

Pro

duct

pic

ture

s, R

ober

t Pee

k Fo

togr

afie

- F

otol

ia

PPM8

Table Top Microphone Consolesfor Commercial Use

CD-Touch

Wallmount Monitored Touch-Screen Paging Console

CD8 - CD16

Wallmount Monitored Paging Console

URGP32in

Alarm Input Interface for

IDA8 and DIVA8 Systems

Page 47: ateis-PAVA2013-online.pdf

Public Address - Voice Alarm

Audio Distribution over IP

Commercial Audio

Intelligent Acoustic Solutions

Intercommunication

Loudspeakers

PSS - paging console, CD-touch -

wallmount monitored touch-screen

paging console, PPM8 - unidirec-

tionnal condenser addressable

microphone and CD8, CD16 - wal-

lbox security paging consoles,

respond to Public Address and Voice

Alarm requirements with specific

attibutes for compliance in small,

medium and large installations.

PSS

Colour Touch-Screen Secure Paging Console

Consoles and Accessories

Page 48: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

48

COLOR TOUCH-SCREEN SECURE PAGING CONSOLE

PSS

The PSS paging console is a man-machine interface which allows call-paging, message broadcasting and DSP matrix parameter control over a secure (monitored) bus. The backlit full-colour touch screen is designed for simple, user-friendly operation and offers a total of 168 software keys across 12 pages for zone or group of zones selections. Each key contains a colour-changing field indicating that the zone is occupied by a different process. Alongside the touch screen, three hardware keys are also provided for free assignment within the software.

Several levels of operation with password protection make the PSS a versatile device that fits as well in a commercial shopping centre as in an industrial high-security environment. All paging parameters needed for site operation can be pre-programmed; zones can be assigned to different buttons, named and grouped, message triggering set up and level adjustments and pre-call chime set. In addition, fader control, button control and event control can also be pre-configured. The message and the chime are stored in the PSS console.

The PSS is powered over Ethernet via CAT-5 (FTP/STP), however if PoE is not available it can be locally powered using a 24V DC supply.

Note: There are two versions of the PSS paging console with identical hardware and functionality but different firmware for compatibility with different systems.

PSS-AS: Used with IDA8 system and ECS system controllers and slaves PSS-G2: Used with DIVA8 system controllers

The ATEIS range of security systems complies with current architectural demands requiring IP and/or fibreoptic networking to cater for any possible PAVA design, however complex. ATEIS responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

Main CharaCteriStiCS

• Secured CAT-5 link to controllers and slaves

• Supervision of microphone capsule

• Monitoring loudspeaker

• 5” full colour touch-screen, 800 x 480 pixels

• 14-pages x 12 keys

• Power indicator

• Status and fault indicator

•Comprehensive system status information from touch-screen

• EN54-16 certified

ControlS and indiCatorS

Front

• 5” full colour touch-screen, 800x480 pixels

• Three LED status indicators

• Three hardware function keys-buttons

• 280 mm goose-neck microphone

interConneCtionS

• RJ45 for CAT-5 connection (POE)

• 3.5mm mini-jack for headset

• Additional power supply connector for long-line support.

Page 49: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

49

PartS inCluded

Quantities Components

1 PSS-XX

1 CAT-5 cable, 1.5 m

teChniCal SPeCifiCationS

Electrical

Battery power supply

Voltage 18 - 26 VDC

Power consumption 250 mA

Performance

Frequency response -3 dB @ 200 Hz to 8 kHz

THD < 1% @ 1 kHz

Output level Max 6 dBu

Noise gate threshold -84 dBu – 24 dBu

Attack time 8 ms

Release time 100 ms

Output impedance 100 Ohm

Monitoring speaker

Impedance 4 Ohm

Output power 1 W @ 1 Khz

Frequency response -3 dB @ 200 to 12 kHz

Headset

Connector 3.5 mm mini-jack

Cable

Cable type CAT-5 (FTP)

Length 100 m

Mechanical

Dimensions (H x W x D) 75 x 250 x 140 mm

Weight 1.1 kg (2.4 lb)

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

COLOUR TOUCH-SCREEN SECURE PAGING CONSOLE

PSS

inStallation noteS

1. Gooseneck microphone

2. Power indicator

3. Fault indicator

4. EVAC indicator

5. Left function button

6. Middle function button

7. Right function button

8. Monitor loudspeaker

9. Touch-screen

inStallation noteS

1. Jack input for external microphone

2. Jack output for external loudspeaker

3. Telephone input

4. CAT5

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe Safety IEC 60065-98

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

Page 50: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

50

WALLMOUNT MONITORED TOUCH-SCREEN PAGING CONSOLE

CD-Touch

The CD-TOUCH paging console is a paging interface that allows call-paging, message broadcasting and DSP matrix parameter control. It contains a 5” full-colour backlit touch-screen for simple, user-friendly operation. The screen offers up to 168 buttons across 12 pages which can be freely assigned in the software to any zone or group of zones. Each key contains a colour-changing field indicating if the zone is occupied by a different process. In addition, the CD-TOUCH has 3 hardware keys that can be assigned within the system control software.

All paging parameters for site operation can be pre-programmed and stored within the console, including message triggering, level adjustment and pre-call chime setup. Zone assignment, naming and grouping can also be preconfigured.

The CD-Touch-XX units connect to a monitored bus on CAT-5 FTP/STP. This connection also provides Power Over Ethernet (POE). In case POE is not available, or if the cable run is greater than 100m, an additional power connection is provided for 24V DC.

The ATEÏS range of security systems complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. ATEÏS responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

CD-TOUCH is available in two different versions for compatibility with different systems. Both are identical in hardware and functionality but require different firmware.

CD-TOUCH-AS: For use with IDA8 and ECS system controllers and slaves CD-TOUCH-G2: For use with DIVA8 system controllers

Main CharaCteriStiCS

• Wall-mount metal enclosure with lockable cover

• Secured CAT-5 link to controllers and slaves

• Monitoring of microphone capsule

• Monitoring loudspeaker

• 5” full colour touch-screen, 800x480 pixels

• 14 pages of 12 buttons

• Power, Fault and Evac indicators

•Comprehensive system status information from touch-screen

• EN54-16 certified

ControlS and indiCatorS

Front

• 5” full colour touch-screen, 800 x 480 pixels

• Three LED status indicators

• Three hardware function keys

• Fireman’s fist microphone with PTT switch

interConneCtionS

• RJ45 for CAT-5 connection (POE and data)

•Additional power supply connector (for 24 V DC external supply in POE not available)

Page 51: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

51

PartS inCluded

Quantities Components

1 CD-Touch-XX

1 CAT-5 cable, 1 m

teChniCal SPeCifiCationS

Electrical

Battery power supply

Voltage 18 - 26 VDC

Power consumption 250 mA

Performance

Frequency response -3 dB @ 40 Hz and 18 kHz

THD < 0,1% @ 1 kHz

Output level Max -6 dBu

Noise gate threshold -84 dBu – 24 dBu

Attack time 8 ms

Release time 100 ms

Output impedance 100 Ohm

Monitoring speaker

Impedance 4 Ohm

Output power 1 W @ 1 Khz

Frequency response -3 dB @ 200 to 12 kHz

Ordering information

CD-TOUCH-G2 For DIVA8

CD-TOUCH-AS For IDA8 and ECS

System Connection

Cable type CAT-5 (FTP)

Length 100 m (max.)

Mechanical

Dimensions (H x W x D) 210 x 400 x 130 mm

Weight 4.5 kg (9.9 lb)

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

inStallation noteS

1. Fireman’s microphone hook

3. Power indicator

4. Fault indicator

5. EVAC indicator

6. Monitor loudspeaker

7. Fireman’s microphone connector

8. Left-hand function

9. Middle function button

10. Right-hand function button

11. Colour touch-screen

WALLMOUNT MONITORED TOUCH-SCREEN PAGING CONSOLE

CD-Touch

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

Page 52: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

52

TABLE TOP MICROPHONE CONSOLES FOR COMMERCIAL USE

PPM8

PPM8 is a uni-directional addressable condenser paging microphone compatible with IDA8 and DIVA8 systems. PPM8 uses RS485 protocol over a single CAT-5 cable connection to transport both audio and power from the paging console to the system units. The PPM8 has 8 zone buttons with a sleek gooseneck microphone, providing both durability and aesthetics in a slim, stable chassis.

The PPM8 enables live announcement to any pre-assigned zones (an optional SP version also allows broadcast of pre-recorded messages). The paging station has a gooseneck microphone, a push-to-talk button, zone selection keys and a monitor speaker. Buttons can represent a single zone or a group of zones and are easily defined in the software using a simple matrix selection. All buttons can be programmed with drag & drop features from the software and each button can be programmed for PTT (Push To Talk) or latching functionality.

In addition to the zone LEDs, “Hold” and “Busy” LED signals make this an extremely user-friendly paging console. The uni-directional condenser microphone ensures high-quality directive signal pick-up from the user with minimal interference from the surroundings thanks to the cardioid polar pick-up pattern. In accordance with BS5839, the PPM8 is monitored on RS485.

The RS485 communication protocol allows daisy-chaining up to 300m on a single CAT-5 cable (FTP/STP) and makes each station easy to connect using standard RJ45 connectors and the junction connection box (supplied with PPM8). If Power over Ethernet is not available, or the CAT-5 cable is over 50m long, the console can be powered locally with a 24 VDC supply.

Note: There are two versions of the PPM8 paging console with identical hardware and functionality but different firmware for compatibility with different systems.

PPM8-AS: Used with IDA8 system and ECS system controllers and slaves PPM8-G2: Used with DIVA8 system controllers

Main CharaCteriStiCS

• Desktop enclosure

• Monitored CAT-5 link to controllers and slaves

• Supervision of microphone capsule (not on slave units)

•8-zone selection keys (Expandable with additional wwkeypads)

• All-call key

• Power indicator

• EVAC indicator

• Status and fault indicator

• Monitor speaker

ControlS and indiCatorS

Front

• Three LED status indicators

• Activity indicators

• Zone selection keys-buttons

• Gooseneck microphone

• Monitor speaker

interConneCtionS

• RJ45 for CAT-5 connection (POE)

Page 53: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

53

PartS inCluded

Quantities Components

1 PPM8-XX

1 Junction box

1 CAT-5 cable, 1,5 m

teChniCal SPeCifiCationS

Electrical

Battery power supply

Voltage 18 - 26 VDC

Power consumption 120 mA

Performance

Frequency response -3 dB @ 40 Hz and 20 kHz

THD < 0,1% @ 1 kHz

Output level Max 6 dBu

Noise gate threshold -84 dBu – 24 dBu

Attack time 8 ms

Release time 100 ms

Output impedance 100 Ohm

Monitoring speaker

Impedance 4 Ohm

Output power 1 W @ 1 Khz

Frequency response 3 dB @ 200 to 12 kHz

Ordering information

Model Description

PPM8-AS Console device, remote paging console

PPM8-AS KEYPAD Console accessory, expansion keypad

PPM8-G2 Console device, remote paging console

PPM8-G2 KEYPAD Console accessory, expansion keypad

PPM/PSM/JB* Console accessory, junction box

Note

* Junction box is supplied with PPM8-XX

Cable

Cable type CAT-5 (FTP)

Length 100 m

Mechanical

Dimensions (H x W x D) 50 x 105 x 190 mm350 x 105 x 190 mm (incl. gooseneck)

Weight 4.7 kg (10.4 lb)

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

IP-rating 30

inStallation noteS

1. Microphone

2. Monitor loudspeaker

3. FAULT indicator

4. EVAC indicator

5. POWER indicator

6. BUSY indicators

7. SELECTION indicator

8. ALL-CALL indicator

9. ALL-CALL and RELEASE

10. Push To Talk button

11. TALK indicator

12. BUSY indicator

TABLE TOP MICROPHONE CONSOLES FOR COMMERCIAL USE

PPM8

Ordering information

PPM8G2-Vxx (For DIVA8 System)

PPM8AS-Vxx (For IDA8 System & ECS)

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe Safety IEC 60065-98

Immunity according to EN50103-4

Page 54: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

54

WALLMOUNT MONITORED PAGING CONSOLE

CD-8

The CD-8 paging console is a remote paging interface with Access Level 2 protection in compliance with EN54-16. Compatible with DIVA8 and IDA8 PAVA systems, the unit serves up to eight zones individually with an All-Call option. Zone selection buttons and fireman’s fist microphone are encased in a heavy-duty IP30 wallmount metal box with lockable door.

The CD-8 console use the same architecture as the PPM paging console, with a junction box built into the enclosure for daisy-chaining multiple units (note that only the first console in the chain is monitored). The maximum recommended distance between units is 100m. As with the PPM paging console, the CD-8 zone buttons can represent a single zone or group of zones and are easily programmed through the system GUI using “drag and drop” functionality. The Push-To-Talk button can be programmed for PTT or latching operation. System status indicators show the status of all zones and indicators are also provided for Power, EVAC and Fault.

The CD-8 is powered over RS485 via CAT-5 (FTP/STP), however if power is not available over RS485 it can be locally powered using a 24V DC supply.

Note: There are two versions of the CD-8 paging console with identical hardware and functionality but different firmware for compatibility with different systems.

CD-8-AS: Used with IDA8 system and ECS system controllers and slaves (max one monitored CD-8 per PDC port with up to 10 units daisy-chained from each. An external power supply should be added for every third unit in the chain).

CD-8-G2: Used with DIVA8 system controllers (max 11 CD-8 in a daisy-chained configuration, only first unit is monitored. An external power supply should be added for every third unit in the chain).

The ATEIS range of security systems complies with current architectural demands requiring IP and/or fibreoptic networking to cater for any possible PAVA design, however complex. ATEIS responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

Main CharaCteriStiCS

• Wall-mount enclosure

• Secured CAT-5 link to controllers and slaves

• Monitoring of microphone capsule

• 8-zone selection buttons

• All-call button

• LED test button

• Power indicator

• EVAC indicator

• Status and fault indicator

• EN54-16 certified

ControlS and indiCatorS

Front

• Three LED status indicators

• Activity indicators

• Zone selection buttons

• LED test

• Fireman’s fist microphone with PTT

interConneCtionS

• RJ45 for CAT-5 connection (POE)

Page 55: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

55

PartS inCluded

Quantities Components

1 CD-8

1 CAT-5 cable, 1.5 m

teChniCal SPeCifiCationS

Electrical

Power supply RS485 (RJ45/CAT-5)

DC/battery power requirements:

Voltage 18 - 26 VDC

Power consumption 120 mA

Performance

Frequency response -3 dB @ 200 to 8kHz

THD < 1% @ 1 kHz

Output level Max 6 dBu

Noise gate threshold -84 dBu – 24 dBu

Attack time 8 ms

Release time 100 ms

Output impedance 100 Ohms

Monitoring speaker

Impedance 4 Ohms

Output power 1 W @ 1 Khz

Frequency response -3 dB @ 200 to 12 kHz

Ordering information

CD8-G2 For DIVA8-Systems

CD8-AS For IDA8-Systems

System Connection

Cable type CAT-5 (FTP)

Max Length 100 m

Mechanical

Dimensions (H x W x D) 190 x 320 x 130 mm

Weight 3.6 kg (7.9 lb)

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

IP rating 30

inStallation noteS

1. Fireman’s microphone hook

2. LED test

3. TALK indicator

4. BUSY indicators

5. SELECTION indicator

6. Monitor loudspeaker (Audible warning)

7. Fireman’s microphone connector

8. ALL-CALL and RELEASE

9. ALL-CALL indicator

10. Zone selections buttons

11. POWER indicator

12. EVAC indicator

13. FAULT indicator

WALLMOUNT MONITORED PAGING CONSOLE

CD-8

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

Page 56: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

56

WALLMOUNT MONITORED PAGING CONSOLE

CD-16

The CD-16 paging console is a remote paging interface with Access Level 2 protection in compliance with EN54-16. Compatible with DIVA8 and IDA8 PAVA systems, the unit serves up to 16 zones individually with an All-Call option. Zone selection buttons and fireman’s fist microphone are encased in a heavy-duty IP30 wallmount metal box with lockable door.

The CD-16 console use the same architecture as the PPM paging console, with a junction box built into the enclosure for daisy-chaining multiple units (note that only the first console in the chain is monitored). The maximum recommended distance between units is 100m. As with the PPM paging console, the CD-16 zone buttons can represent a single zone or group of zones and are easily programmed through the system GUI using “drag and drop” functionality. The Push-To-Talk button can be programmed for PTT or latching operation. System status indicators show the status of all zones and indicators are also provided for Power, EVAC and Fault.

The CD-16 is powered over RS485 via CAT-5 (FTP/STP), however if power is not available over RS485 it can be locally powered using a 24V DC supply.

Note: There are two versions of the CD-16 paging console with identical hardware and functionality but different firmware for compatibility with different systems.

CD-16-AS: Used with IDA8 system and ECS system controllers and slaves (max one monitored CD-16 per PDC port with up to 10 units daisy-chained from each. An external power supply should be added for every third unit in the chain).

CD-16-G2: Used with DIVA8 system controllers (max 11 CD-16 in a daisy-chained configuration, only first unit is monitored. An external power supply should be added for every third unit in the chain).

The ATEIS range of security systems complies with current architectural demands requiring IP and/or fibreoptic networking to cater for any possible PAVA design, however complex. ATEIS responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

ControlS and indiCatorS

Front

• Three LED status indicators

• Activity indicators

• Zone selection buttons

• LED test

• Fireman’s fist microphone with PTT

interConneCtionS

• RJ45 for CAT-5 connection (POE)

Main CharaCteriStiCS

• Wall-mount enclosure

• Secured CAT-5 link to controllers and slaves

• Monitoring of microphone capsule

• 8-zone selection buttons

• All-call button

• LED test button

• Power indicator

• EVAC indicator

• Status and fault indicator

• EN54-16 certified

Page 57: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

57

PartS inCluded

Quantities Components

1 CD-16

1 CAT-5 cable, 1.5 m

teChniCal SPeCifiCationS

Electrical

Power supply RS485 (RJ45/CAT-5)

DC/battery power requirements:

Voltage 18 - 26 VDC

Power consumption 150 mA

Performance

Frequency response -3 dB @ 200 to 8kHz

THD < 1% @ 1 kHz

Output level Max 6 dBu

Noise gate threshold -84 dBu – 24 dBu

Attack time 8 ms

Release time 100 ms

Output impedance 100 Ohms

Monitoring speaker

Impedance 4 Ohms

Output power 1 W @ 1 Khz

Frequency response -3 dB @ 200 to 12 kHz

Ordering information

CD16-G2 For DIVA8-Systems

CD16-AS For IDA8-Systems

System Connection

Cable type CAT-5 (FTP)

Max Length 100 m

Mechanical

Dimensions (H x W x D) 130 x 350 x 130 mm

Weight 4.7 kg (10.4 lb)

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

IP rating 30

inStallation noteS

1. Fireman’s microphone hook

2. BUSY indicators

3. FAULT indicator

4. Monitor loudspeaker (Audible warning)

5. Fireman’s microphone connector

6. TALK indicator

7. LED test

8. SELECTION indicator

9. ALL-CALL and RELEASE

10. ALL-CALL indicator

11. Zone selections buttons

12. BUSY indicators

13. SELECTION indicator

14. Zone selections buttons

15. POWER indicator

16. EVAC indicator

WALLMOUNT MONITORED PAGING CONSOLE

CD-16

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe CE CE – 0359 (Intertek)

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

Page 58: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

58

ALARM INPUT INTERFACE FOR IDA8-System and DIVA8-System

URGP32in

funCtionS

The URGP is a contact interface extension unit to the IDA8 System and DIVA8 System.

Each URGP provides 32 additional alarm inputs. Each input is monitored and can be programmed to trigger a digital audio message into a specific zone or group of zones. The URGP is linked to the System units through an RS232 /RS485 monitored serial link.

Main CharaCteriStiCS

• Desktop enclosure

• Secured RS232/RS485 link to controllers and slaves

• 32 alarm inputs

• Status and fault indicator

ControlS and indiCatorS

Front

• Three LED status indicators

• EVACUATION active indicator

• FAULT indicator

• POWER indicator

interConneCtionS

• RJ45

• RS232

CertifiCationS and aPProvalS

inStallation/Configuration noteS

1Audio outputs: maximum level + 5 dB, bandwidth 20 Hz - 20 kHz

2

3

4

5

6

7

8

9

10

11

region CertifiCationS

Europe Safety IEC 60065-98

Immunity according to EN50103-4

PAVA EN54-16 certified 2012

Page 59: ateis-PAVA2013-online.pdf

Consoles & Accessor ies

59

PartS inCluded

Quantities Components

1 URGP

1 connector set

1 CAT-5 cable, 1 m

teChniCal SPeCifiCationS

Electrical

Battery power supply

Voltage 18 - 26 VDC

Power consumption 30 mA

System

Evacuation inputs

Contact mode 5 VDC

Voltage mode -6 dBu

Monitoring resistor 4K7 Ohm

Cable

Cable type CAT-5 (FTP)

Length RS485 up to 600 m

RS232 up to 15 m

Mechanical

Dimensions (H x W x D) 44 x 140 x 75 mm

Weight 0.5 kg (1.1 lb)

Colour RAL7016

Environmental

Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)

Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity 15% to 90%

Air pressure 600 to 1100 h Pa

Ordering Information

Model Description

URGP-32in Accessory, Alarm input interface

ALARM INPUT INTERFACE FOR IDA8-System and DIVA8-System

URGP32in

front indiCatorS

1. EVACUATION contacts activated

2. FAULT contacts activated

3. POWER indicator

rear

1. 24 VDC input

2. RS485 interface to IDA8 and DIVA8

3. RS232 interface to IDA4

4. EVAC inputs

5. FAULT inputs

Page 60: ateis-PAVA2013-online.pdf

GERMANY - U

AE -

TAIW

AN -

NET

HERL

ANDS

-

SWITZERLAND - UNITED-KINGDOM - FRANCE - USA - CHINA SINGAPORE

Where to find us?With over 10 branch offices and more than 40 representatives around the globe, ATEÏS may call itself a multinational in development and manufacturing of electronic solutions for the Voice-Alarm, Commercial Audio, Communication and Conferencing markets. With 30 years of experience in development and manufacturing, ATEÏS holds factories in Europe and Asia where we lead a team of more than 40 dedicated highly qualified engineers who are working solely on state of the art technology.

For us, the test is to be seen as the best in our business by all; our customers, employees and suppliers. That’s why we are constantly on the outlook for ways to strengthen our organisation, expand our portfolio and our geographical presence.

All to provide better service and support!

Penton/ATEIS USA.21 Sabin St. Pawtucket, RI 02860 - USAPhone: 401-727-1600 - Fax: [email protected]

ATEÏS SE PTE LTD Blk 209 New Upper - Rd #04-631 - SINGAPORE 460209Phone: +65 6456 4448 - Fax: +65 6451 [email protected]

ATEÏS CHINARoom 610, No. 255 Wubao Road, Minxing districtShanghai - CHINAPhone: 021-54495191/92 - Fax: [email protected]

ATEÏS Europe B.V. Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDS Phone: +31 (0)10 2088690 - Fax: +31 (0)10 [email protected]

ATEÏS Germany GmbH. Kirchenstrasse 11 – 82194 Gröbenzell – DEUTSCHLANDPhone: +49 (0) 8142 305070-30 – Fax: +49 (0) 8142 [email protected]

ATEÏS France SAS. 34, av de l’europe - ZA de Font Ratel - 38640 Claix - FRANCE Phone: +33 (0)4 76 99 26 30 - Fax: +33 (0)4 76 99 26 31Sales: +33 (0)4 76 99 26 37 [email protected]

ATEÏS Suisse SAChemin du Dévent, 1024 Ecublens - SWITZERLANDPhone: +41 (0)21 881 25 10 - Fax: +41 (0)21 881 25 09 [email protected]

ATEÏS FAR EAST CORP2F, No.60, Xing Hua 2nd Rd., Taizi, Taichung county, 427 - TAIWAN, R.O.C.Phone: +886 4 25333820 - Fax: +886 4 [email protected]

ATEÏS Middle FZCO.LIU 11 Dubai - Silicone Oasis - DUBAI UNITED ARAB EMIRATESPhone: +971 4 3262730 - Fax: +971 4 3262731 [email protected]

Del iver ing Your Message

ATEÏ

S re

serv

e th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otic

eHE

LPRO

D.CO

M -

Pro

duct

pic

ture

s, R

ober

t Pee

k Fo

togr

afie

- F

otol

ia