ashland’s automation portfolio - the mcilvaine … · ashland’s automation portfolio a patented...

11
ASHLAND’S AUTOMATION PORTFOLIO A patented and proprietary Technology Platform that encompasses the latest innovations in: On Line Performance Monitoring Mobile and Cloud Water Treatment Process Control 1 Confidential and proprietary. •Using Extremely accurate water and process Performance Analyzers •Offers “Proof of Performance” Mobile and Cloud Computing •Data Management Services Process Control •State-of-the-art controllers •Imbedded algorithms for PBC* and KBC* *Performance Based Control *Knowledge Based Control

Upload: buimien

Post on 25-Jul-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

ASHLAND’S AUTOMATION PORTFOLIO

A patented and proprietary Technology Platform that encompasses the latest innovations in:

On Line Performance Monitoring

Mobile and Cloud Water Treatment Process Control

1 Confidential and proprietary.

•Using Extremely accurate water and process Performance Analyzers •Offers “Proof of Performance”

Mobile and Cloud Computing•Data Management Services

Process Control•State-of-the-art controllers •Imbedded algorithms for PBC* and KBC*

*Performance Based Control*Knowledge Based Control

EVOLUTION OF WATER TREATMENT MONITORING

Manual Chemical Analysis

• Gives a `snapshot ‘ of your water chemistry

Corrosion & Scale Coupons

• Provides data on historical system condition

Real-time chemical monitoring

• Measures chemical levels and provides feedback if dosing problems

Real-time performance monitoring and control

• Most accurate and meaningful feedback on

2 Confidential and proprietary.

feedback on system condition

110

130

150

170

190

210

1 50

COOLING WATER PERFORMANCE MONITORING

3 Confidential and proprietary.

Corrater Fouling Monitor

ONGUARD™ 2-PLUS CONTROL SYSTEM ProprietaryProprietary

PatentedPatented

4 Confidential and proprietary.

STANDARD CONTROL VS. PERFORMANCE CONTROL

Overfeed

UnderfeedCor

rosi

on –

KP

I

Inhi

bito

r D

osag

e (P

PM

)

OverfeedUnderfeed

Cor

rosi

on –

KP

I

Inhi

bito

r Dos

age

(PP

M)Performance

Based Control

Setpoint

$

$

5 Confidential and proprietary.

Cooling Water Chemical Control Typical inhibitor feed program,

based on tracer level set point or blowdown

Inhi

bito

r D

osag

e (P

PM

)Corrosion Rate Inhibitor

Dosage (PPM)

Cooling Water Performance Monitoring & Control - Continuous

process control responds to process key performance indicators

Inhibitor Dosage (PPM)

Corrosion Rate

Inhi

bito

r

OPERATIONAL & PERFORMANCE MONITORING

KOI’s

pH

ORP

KPI’s

Fouling

General Corrosion Rate

6 Confidential and proprietary.

Cycles

Conductivity

Water Consumption

Chemical Concentration

Imbalance/Pitting Corrosion Index

• HX design or operational values inputted

• Proprietary algorithms duplicate critical plant heat exchangers online- Using Heat Flux and Shear Stress- In compliance with NACE monitoring protocols

COOLING WATER FOULING MONITORING

7 Confidential and proprietary.

• Calculates Fouling Factor- Fouling Factor (FF)x105־ hr ft2 ºF / BTU

• Accounts for all types of fouling - Inorganic and bio-fouling

POWER CASE HISTORY - ONGUARD 2-PLUS OPTIMIZES PROGRA M PERFORMANCE AND INCREASES POWER PRODUCTION $300K/YR

Background

CustomerNeeds

� New England 19 MW zero liquid discharge power plant with 5 ppm iron in well water

� Excessive condenser and tower fill fouling

� Reduce frequency of shutdowns for condenser cleanings� Maintain peak power generation efficiency� Clean-up tower fill

8 Confidential and proprietary.

Ashland Solution

Benefits

� OnGuard™ 2-plus proved fouling and ORP correlation� Relocated chlorination feed to oxidize iron. Prevented

reaction with silica.� Established ORP target for halogen control, removing slime

� Improved power generation 5%; revenue increased over $300,000 per year

� Reduced outages and maintenance costs� Increased side-stream silica removal from 10%-90% via

coagulant optimization reducing fouling tendency

POWER CASE HISTORY - COOLING WATER TECHNOLOGY INCREASES REVENUE $1.6 MILLION, CHEMICAL SPEND CUT 20%

Background

CustomerNeeds

� US independent power producer faced changing environmental discharge restrictions, which limited cooling tower water chemistry control

� Improve fouling and corrosion control� Meet environmental discharge limits

9 Confidential and proprietary.

Ashland Solution

Benefits

� Treatment program including OnGuard™ 2-plus analyzer performance-based monitoring and control equipment and augmentation with Drewsperse 7130 dispersant to eliminate organic fouling

� Increased power generation 6.7 MW; revenue increased over $1.6 million

� Reduced chemical spend 20%� Exceeded corrosion and fouling control targets � Improved condenser cleanliness by 15%

CONDENSER WATER BOX DP WITH DREWSPERSE 7130

13 psid

14 psid

15 psidWaterbox DP

Biopenetrant

Towerbrom

failed to

dump

Began

cycling

0x0

Biopenetrant added

@ 60 ppm 1/24/11

Biopenetrant added

@ 200 ppm 3/4/11

Cell 2 Valved In

Incorrectly

Corrected Cell 2

Water Flow

STG Trip

@ 200

MW

10 Confidential and proprietary.

11 psid

12 psid

13 psid

11/2

1/10

1/10

/11

3/1/

11

4/20

/11

6/9/

11

7/29

/11

9/17

/11

11/6

/11

12/2

6/11

Adjusted CW flow to

design

Design DP (11.7 psi)

Cell 2 Valved Out ForFan Repair

Biopenetrant added @ 60

ppm

MW

Began Clo2Treatment

Tank Levels

Chemical Feedand Control

OnGuard™ Analyzers and Sensors

ONGUARD™ ONLINEPLATFORM INFORMATION ARCHITECTURE

OnGuard ™

OnGuard i Controller

11 Confidential and proprietary.

Ashland Representative

Ashland Applications Support Alarms

DCS / Pi Interface

Performance, Reliability, Cost Efficiency

Customer Access

Reporting

OnGuard ™OnLine