Qualified Abatement Services, Inc. 1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143 ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former Residential Building Located At 2556 Norman Street, Detroit, Michigan Date 11/8/12 Prepared by: Prepared for: Qualified Abatement Services, Inc. 1935 McGraw Street Detroit, Michigan 48208 Phone: (313) 361-6003 Fax: (313) 361-6143 Michigan Land Bank Cadillac Place 3022 West Grand Blvd. , Suite 4-600 Detroit, MI 48202

Upload: others

Post on 28-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former Residential Building Located At 2556 Norman Street, Detroit, Michigan Date 11/8/12

Prepared by: Prepared for: Qualified Abatement Services, Inc. 1935 McGraw Street Detroit, Michigan 48208 Phone: (313) 361-6003 Fax: (313) 361-6143

Michigan Land Bank Cadillac Place 3022 West Grand Blvd. , Suite 4-600 Detroit, MI 48202

Page 2: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

Asbestos Containing Material Report

1

Client Name: Michigan Land Bank

Project Name: Michigan Land Bank ACM Assessments

Project Number: 12-120

Project Site Address (Complete): 2556 Norman Street, Detroit, Michigan

Size of Building (SF): 805 SF

Date of Site Visit: 11/8/12

Site Contact Name: Thomas B. Ross

Site Contact Phone Number: (313) 361-6003

Asbestos Inspection Performed by: Tracy Chaalan (A31317)

Areas Not Accessible: Second Floor and Attic (Burned)

On November 8, 2012, State of Michigan Asbestos Inspector Tracy Chaalan (A31317) from Qualified conducted a pre-demolition Asbestos Containing Material Survey of the unoccupied residential property located at 2556 Norman Street in Detroit, Michigan (Site). The purpose of this survey was to task an accredited asbestos inspector to complete a pre-demolition asbestos and hazardous materials survey of the site and provide recommendation options for removal and disposal prior to demolition of the building. The vacant property consists of a one and half story, wood frame residential building with a basement. There is debris throughout the residential and yard. The second floor is badly burned and stairs are missing. Inspectors entered the building through the side door. Laboratory reports are included in Appendix A. Photographs of the site are included in Appendix B. The following sections summarize Qualified Abatement Services, Inc.’s findings:

TABLE 1 (HAZARDOUS MATERIALS INVENTORY)

Tire Front Yard 1

Material/Item Description Location Approximate Quantity

Page 3: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

2

The following suspect asbestos containing materials (ACM) were determined to be asbestos containing (>1%):

TABLE 2 (ASBESTOS CONTAINING MATERIALS)

The following suspect ACM were sampled and found to not contain more than one percent asbestos:

TABLE 3 (NON-ACM SUSPECT MATERIAL)

NAD = No Asbestos Detected NA = Not Applicable

ID # Material Location Approximate Quantity Result

2-DW-A Duct Wrap Basement 110 SF 65% Chrysotile

2-DW-A Duct Wrap Debris Basement 25 SF 65% Chrysotile

3-PI-A Pipe Insulation Basement 10 LF 45% Chrysotile

5-ST-A,B,C Stair Treads (1” x 1” Cream) Basement Stairs 30 SF 25% Chrysotile

ID # Material Location Approximate Quantity Result

1-SC-A Stack Cement Basement Chimney Stack 3 SF NAD

4-FT-A,B,C Floor Tile (1” x 1” Wood) Foyer 65 SF NAD

5-ST-a,b,c Stair Treads Mastic Basement Stairs 30 SF NAD

6-MLF-A,B,C Multi-Layer

Flooring (1” x1” Brown)

Kitchen 140 SF NAD

7-WG-A,B,C Window Glaze Exterior Windows 400 LF (22 Windows) NAD

8-CT-A,B,C Ceiling Tile (1” x 1” White) Living Room 130 SF NAD

9-PL-A,B,C, D,E,F,G Plaster

1st Floor: Kitchen, Living and Dining Rooms, Stairwell

2nd Floor: Bedroom #1, #2 & #3

6,800 SF NAD

Page 4: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

3

No other suspect ACM or Hazardous Materials were observed on the Site. Although not anticipated based on surface observations, underground structures that could contain ACM may be present and should be managed accordingly if encountered during Site redevelopment. Asbestos is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. ACMs generally do not pose a health threat unless the asbestos fibers are disturbed, become airborne and are inhaled. Contractors working in an area where asbestos is present must be informed of the type and location of ACMs. Abatement of ACMs, including non-friable ACMs, must be performed by a Michigan licensed, certified and registered asbestos abatement contractor in accordance with state and federal Occupational Safety and Health Administration (OSHA) and local air quality management regulations. Lead-based paint may be present on the site and is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. LBP generally does not pose a health threat unless particles are disturbed, become airborne and are inhaled or ingested. Contractors and their employers that will be disturbing the building during demolition should follow all applicable requirements in the OSHA Lead in Construction Standard. Further testing may be required of debris generated from demolition activities to determine whether the debris should be disposed as hazardous waste under the Resource Conservation and Recovery Act (RCRA) in accordance with 40-CFR Part 261 Subpart C.

RECOMMENDATIONS:

Except for the following items listed below, Section 61.145(c) of the Asbestos NESHAP requires that each owner or operator of a demolition or renovation activity involving RACM remove all such material from a facility being demolished or renovated before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access to the material for subsequent removal.

ACM need not be removed before demolition if it:

(i) Is a Category I non-friable ACM that is not friable.

(ii) Is on a facility component that is encased in concrete or other similarly hard material and is adequately wet whenever exposed during demolition.

(iii) Was not accessible for testing and therefore was not discovered until after demolition began and, as a result of the demolition, cannot be safely removed. If not removed for safety reasons, the exposed RACM and any asbestos-contaminated debris must be treated as asbestos-containing waste material and kept adequately wet at all times until disposed of.

(iv) Is a Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.

Demolition with Roofing Materials in Place is covered under the NESHAP regulations (40 CFR Part 61 Subpart M).

Page 5: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

4

Roofing materials were generally not tested during this inspection and therefore the roofing material should be assumed to be Category I asbestos-containing roofing materials. Since demolition activities do not include sanding, grinding, cutting, or abrading, Category I asbestos-containing roofing materials not in poor condition and not friable are not considered RACM and are allowed to remain in place during demolition. If the asbestos-containing roofing material is not in poor condition and is not friable, it may be disposed of in a landfill which accepts ordinary demolition waste.

The asbestos-containing roofing material may not be ground up for recycling into other products. In addition, contractors should ensure they follow all OSHA regulations pertaining to demolition of Category I ACM materials. Category I or II nonfriable ACM that is not subject to 61.150(a)(3) would still have to be disposed of in a landfill that accepts building debris, in a landfill that operates in accordance with 61.154, or at a facility that operates in accordance with 61.155. Qualified Abatement Services, Inc. recommends:

A licensed asbestos abatement company should remove the following materials prior to demolition per NESHAP regulations: 1. Duct wrap and duct wrap debris insulation should be wetted before, during and after removal

using glovebags or full containment work procedures and disposed of as asbestos waste. 2. Pipe insulation should be wetted before, during and after removal using glovebags or full

containment work procedures and disposed of as asbestos waste. 3. Stair treads should be wetted before, during and after removal, placed in impermeable

disposal bags and disposed of as asbestos waste LIMITATIONS: The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during Qualified Abatement Services, Inc. Asbestos Containing Material and Hazardous Materials Survey of the vacant above-referenced residential property located in Detroit, Michigan. Any conditions or materials that could not be visually identified through limited destructive sampling were not inspected and may differ from those conditions or materials noted. The user of this report should keep in mind that conditions may change with time and observations made by Qualified Abatement Services, Inc. at the time of the Site reconnaissance may not be consistent with future observations made by others. Additional materials may be encountered during the demolition process and may require further sampling to determine disposal criteria. The report is designed to aid the building owner, architect, construction manager, general contractors, and potential asbestos abatement contractors in locating asbestos building materials to be removed prior to demolition activities.

Page 6: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

5

Under no circumstances is the report to be utilized as a bidding document or as a project specification document. Contractors bidding the demolition of this Site should field verify project information. Qualified Abatement Services, Inc. appreciates the opportunity to be of service to The Michigan Land Bank on this project. In the meantime if you have questions regarding the information in this report or if we can be of further assistance do not hesitate to contact the undersigned at (313) 361-6003 Sincerely, QUALIFIED ABATEMENT SERVICES, INC.

Thomas B. Ross Project Manager

Attachments

Page 7: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

APPENDIX A

LABORATORY ANALYTICAL RESULTS AND CHAIN OF CUSTODY FORMS

Page 8: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Location:

Layer:

Date Reported:

1-SC-A

Project: 2556 Norman

1

Report To:

1of

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

Lab ID #:

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Appearance:

Sample Information Asbestos Type/Percent Non-Asbestos

Cust. #: 43347 - 01 Other - 100%

No Asbestos ObservedNOAsbestos Present:

grey,nonfibrous,homogenous

Material: Stack Cement

Location:

Layer:

Location:

Layer: grey,fibrous,homogenous

Chrysotile - 65%

Chrysotile - 45%

Appearance: grey,fibrous,homogenous1

Asbestos Present: Lab ID #:

Appearance:

2-DW-AOther - 35%Lab ID #:

Cust. #: 43347 - 02

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

1

Duct Wrap

of

1

Pipe Insulation3-PI-A

Material:

43347 - 03 Other - 55%

Asbestos Present: YES

Material: Cust. #:

YES

For Layered Samples, each component will be analyzed and reported separately.

of 1

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 1 of 12

Page 9: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

Other - 100%

Sample Information Asbestos Type/Percent Non-Asbestos

NO

FoyerAppearance:

Cust. #: Material: 1x1 Wood Block Floor Tile

Lab ID #: 4-FT-A No Asbestos Observed43347 - 04 Asbestos Present:

1 of 2grey,nonfibrous,homogenous

Location:

Layer:

Location:

Layer:

No Asbestos Observed

2 of

4-FT-BLab ID #: Cust. #: No Asbestos Observed

Asbestos Present: NO

Material: Glue4-FT-A

Other - 100%Lab ID #: Cust. #:

43347 - 04a

Other - 100%

FoyerAppearance: clear,nonfibrous,homogenous

2

Foyer

43347 - 05 Asbestos Present: NO

Appearance: grey,nonfibrous,homogenous

For Layered Samples, each component will be analyzed and reported separately.

1 of 2

Material: 1x1 Wood Block Floor Tile

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 2 of 12

Page 10: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

43347 - 05a Asbestos Present: NO

Sample Information Asbestos Type/Percent Non-Asbestos

Material: Glue

Other - 100%Cust. #: 4-FT-B No Asbestos ObservedLab ID #:

FoyerAppearance: clear,nonfibrous,homogenous

2 of 2

Location:

Layer:

Location:

Layer:

Cust. #: 4-FT-CLab ID #:

Asbestos Present: NO Other - 100%

NVLAP Lab Code 102118-0

No Asbestos ObservedLab ID #: 43347 - 06a

Material: 1x1 Wood Block Floor Tile

Asbestos Present: NO Other - 100%No Asbestos Observed

43347 - 06

FoyerAppearance: grey,nonfibrous,homogenous

1 of 2

Cust. #: 4-FT-CMaterial: Glue

2

FoyerAppearance: clear,nonfibrous,homogenous

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

2 of

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 3 of 12

Page 11: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

Lab ID #: 43347 - 07

Appearance: grey,fibrous,homogenous

Material: Cream Stair Tread

Asbestos Present: Other - 75%Cust. #: 5-ST-A Chrysotile - 25%

YES

1 of 2

Basement

Location:

Layer:

Location:

Layer:

Lab ID #: 43347 - 07a Asbestos Present: NO Other - 100%

Material: MasticCust. #: 5-ST-A No Asbestos Observed

2 of 2

BasementAppearance: beige,nonfibrous,homogenous

Lab ID #: 43347 - 08 Asbestos Present:

Material: Cream Stair TreadCust. #: 5-ST-B

of

Basement NOT ANALYZEDAppearance:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

NVLAP Lab Code 102118-0

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 4 of 12

Page 12: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

Cream Stair TreadCust. #: 5-ST-C

NOT ANALYZEDAppearance:

BasementMaterial:

of

Sample Information Asbestos Type/Percent Non-Asbestos

43347 - 09Lab ID #: Asbestos Present:

Location:

Layer:

Location:

Layer:

NVLAP Lab Code 102118-0

grey,nonfibrous,homogenousAppearance:

Cust. #: 6-MLF-A

Kitchen

No Asbestos ObservedMaterial: Floor Tile

Lab ID #: Asbestos Present: 43347 - 10 NO Other - 100%

NO Other - 100%

1 of 3

Lab ID #: 43347 - 10a Asbestos Present: Cust. #: 6-MLF-A No Asbestos ObservedMaterial: Floor Tile

Kitchen

of 3

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

Appearance: grey,nonfibrous,homogenous

Robert T. Letarte Jr., Laboratory Director

2

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 5 of 12

Page 13: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 3 of 3

KitchenAppearance: black,nonfibrous,homogenous

Cust. #: 6-MLF-A No Asbestos ObservedMaterial: Mastic

Sample Information Asbestos Type/Percent Non-Asbestos

Lab ID #: 43347 - 10b Asbestos Present: NO Other - 100%

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

2 of 3Appearance: brown,nonfibrous,homogenous

Material: Floor TileKitchen

NO Other - 100%Cust. #: 6-MLF-B No Asbestos ObservedLab ID #: 43347 - 11a Asbestos Present:

1 of 3Appearance: grey,nonfibrous,homogenous

Material: Floor TileKitchen

NO Other - 100%Cust. #: 6-MLF-B No Asbestos ObservedLab ID #: 43347 - 11 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 6 of 12

Page 14: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 3 of 3

KitchenAppearance: black,fibrous,homogenous

Asbestos Present:

Material: Mastic

NO Cellulose - 30%Cust. #: 6-MLF-B No Asbestos Observed Other - 70%Lab ID #: 43347 - 11b

Sample Information Asbestos Type/Percent Non-Asbestos

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

2 of 3Appearance: beige,nonfibrous,homogenous

Material: Floor TileKitchen

NO Other - 100%Cust. #: 6-MLF-C No Asbestos ObservedLab ID #: 43347 - 12a Asbestos Present:

1 of 3Appearance: grey,nonfibrous,homogenous

Material: Floor TileKitchen

NO Other - 100%Cust. #: 6-MLF-C No Asbestos ObservedLab ID #: 43347 - 12 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 7 of 12

Page 15: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 3 of 3

KitchenAppearance: black,fibrous,homogenous

Asbestos Present:

Material: Mastic

NO Cellulose - 30%Cust. #: 6-MLF-C No Asbestos Observed Other - 70%Lab ID #: 43347 - 12b

Sample Information Asbestos Type/Percent Non-Asbestos

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1 of 1Appearance: beige,nonfibrous,homogenous

Material: Window Glaze

NO Other - 100%Cust. #: 7-WG-B No Asbestos ObservedLab ID #: 43347 - 14 Asbestos Present:

1 of 1Appearance: beige,nonfibrous,homogenous

Material: Window Glaze

NO Other - 100%Cust. #: 7-WG-A No Asbestos ObservedLab ID #: 43347 - 13 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 8 of 12

Page 16: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 1 of 1Appearance: beige,nonfibrous,homogenous

Asbestos Present:

Material: Window Glaze

NO Other - 100%Cust. #: 7-WG-C No Asbestos ObservedLab ID #: 43347 - 15

Sample Information Asbestos Type/Percent Non-Asbestos

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1 of 1Appearance: brown,fibrous,homogenous

Material: 1x1 Ceiling TileLiving Room

NO Cellulose - 90%Cust. #: 8-CT-B No Asbestos Observed Other - 10%Lab ID #: 43347 - 17 Asbestos Present:

1 of 1Appearance: brown,fibrous,homogenous

Material: 1x1 Ceiling TileLiving Room

NO Cellulose - 90%Cust. #: 8-CT-A No Asbestos Observed Other - 10%Lab ID #: 43347 - 16 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 9 of 12

Page 17: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 1 of 1

Living RoomAppearance: brown,fibrous,homogenous

Asbestos Present:

Material: 1x1 Ceiling Tile

NO Cellulose - 90%Cust. #: 8-CT-C No Asbestos Observed Other - 10%Lab ID #: 43347 - 18

Sample Information Asbestos Type/Percent Non-Asbestos

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1 of 1Appearance: grey,fibrous,nonhomogenous

Material: PlasterDining Room

NO Cellulose - 2%Cust. #: 9-PL-B No Asbestos Observed Other - 98%Lab ID #: 43347 - 20 Asbestos Present:

1 of 1Appearance: grey,fibrous,nonhomogenous

Material: PlasterLiving Room

NO Cellulose - 2%Cust. #: 9-PL-A No Asbestos Observed Other - 98%Lab ID #: 43347 - 19 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 10 of 12

Page 18: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 1 of 1

KitchenAppearance: grey,fibrous,nonhomogenous

Asbestos Present:

Material: Plaster

NO Cellulose - 2%Cust. #: 9-PL-C No Asbestos Observed Other - 98%Lab ID #: 43347 - 21

Sample Information Asbestos Type/Percent Non-Asbestos

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1 of 1Appearance: grey,fibrous,nonhomogenous

Material: Plaster2nd FL Bedroom 1

NO Cellulose - 2%Cust. #: 9-PL-E No Asbestos Observed Other - 98%Lab ID #: 43347 - 23 Asbestos Present:

1 of 1Appearance: grey,fibrous,nonhomogenous

Material: PlasterStairwell

NO Cellulose - 2%Cust. #: 9-PL-D No Asbestos Observed Other - 98%Lab ID #: 43347 - 22 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 11 of 12

Page 19: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2556 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB NTP#2

11/14/12

11/08/1211/09/1211/14/12

12-43347Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 1 of 1

2nd FL Bedroom 2Appearance: grey,fibrous,nonhomogenous

Asbestos Present:

Material: Plaster

NO Cellulose - 2%Cust. #: 9-PL-F No Asbestos Observed Other - 98%Lab ID #: 43347 - 24

Sample Information Asbestos Type/Percent Non-Asbestos

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

ofAppearance:

Material: Cust. #: Lab ID #: Asbestos Present:

1 of 1Appearance: grey,fibrous,nonhomogenous

Material: Plaster2nd FL Bedroom 3

NO Cellulose - 2%Cust. #: 9-PL-G No Asbestos Observed Other - 98%Lab ID #: 43347 - 25 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 12 of 12

Page 20: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing
Page 21: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

APPENDIX B

SITE PHOTOGRAPHS

Page 22: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2556 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of the Front of 2556 Norman Street

View of the Side of 2556 Norman Street

Page 23: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2556 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of the Side of 2556 Norman Street

View of the Back of 2556 Norman Street

Page 24: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2556 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Duct Wrap

View of Duct Wrap Debris

Page 25: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2556 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Pipe Insulation

View of Stair Treads in Basement

Page 26: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2556 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Debris in Residential

View of Missing 2nd Floor Stairs

Page 27: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2556 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Debris in Yard

View of Tire in Front Yard

Page 28: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former Residential Building Located At 2423 Norman St., Detroit, Michigan Date 11/8/12

Prepared by: Prepared for: Qualified Abatement Services, Inc. 1935 McGraw Street Detroit, Michigan 48208 Phone: (313) 361-6003 Fax: (313) 361-6143

Michigan Land Bank Cadillac Place 3022 West Grand Blvd. , Suite 4-600 Detroit, MI 48202

Page 29: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

Asbestos Containing Material Report

1

Client Name: Michigan Land Bank

Project Name: Michigan Land Bank ACM Assessments

Project Number: 12-120

Project Site Address (Complete): 2423 Norman Street, Detroit, Michigan

Size of Building (SF): 800 SF

Date of Site Visit: 11/8/12

Site Contact Name: Thomas B. Ross

Site Contact Phone Number: (313) 361-6003

Asbestos Inspection Performed by: Tracy Chaalan (A31317)

Areas Not Accessible: All Interior Areas Accessed

On November 8, 2012, State of Michigan Asbestos Inspector Tracy Chaalan (A31317) from Qualified conducted a pre-demolition Asbestos Containing Material Survey of the unoccupied residential property located at 2423 Norman Street in Detroit, Michigan (Site). The purpose of this survey was to task an accredited asbestos inspector to complete a pre-demolition asbestos and hazardous materials survey of the site and provide recommendation options for removal and disposal prior to demolition of the building. The vacant property consists of a one and a half story, wood frame with asphalt siding residential building with a basement and a detached garage. There is debris throughout the house. Inspectors entered the building through the back door. Laboratory reports are included in Appendix A. Photographs of the site are included in Appendix B. The following sections summarize Qualified Abatement Services, Inc.’s findings:

Page 30: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

2

. TABLE 1 (HAZARDOUS MATERIALS INVENTORY)

Tires Garage 2 Computer Monitors Basement 9

Paints Basement 4 (1 Gallon) Television Basement 1 Unknown Basement 3 (Quarts) Television 2nd Floor 1

Paint 2nd Floor 1(Quarts) Television Dining Room 1

Computer Equipment Dining Room 2 Keyboards and 1 Monitor

The following suspect asbestos containing materials (ACM) were determined to be asbestos containing (>1%):

TABLE 2 (ASBESTOS CONTAINING MATERIALS)

The following suspect ACM were sampled and found to not contain more than one percent asbestos:

TABLE 3 (NON-ACM SUSPECT MATERIAL)

NAD = No Asbestos Detected NA = Not Applicable

Material/Item Description Location Approximate Material Quantity

ID # Material Location Approximate Quantity Result

3-WG-A,B,C Window Glaze Exterior Windows 270 LF (18 windows) 1.75% Chrysotile (Point Count)

ID # Material Location Approximate Quantity Result

1-ES-A,B,C Exterior Asphalt Siding Exterior Siding 1,400 SF NAD

2-SC-A Stack Cement Basement Chimney Stack 4 SF NAD

4-FT-A,B,C Floor Tile (1” x 1” Beige/Grey)

Kitchen, Dining Room and Hallway 180 SF NAD

4-FT-a,b,c Floor Tile Mastic Kitchen, Dining Room and Hallway 180 SF NAD

5-PL-A,B, C,D,E Plaster

Kitchen, Living and Dining Rooms,

2nd Floor Bedroom 5,000 SF NAD

Page 31: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

3

No other suspect ACM or Hazardous Materials were observed on the Site. Although not anticipated based on surface observations, underground structures that could contain ACM may be present and should be managed accordingly if encountered during Site redevelopment. Asbestos is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. ACMs generally do not pose a health threat unless the asbestos fibers are disturbed, become airborne and are inhaled. Contractors working in an area where asbestos is present must be informed of the type and location of ACMs. Abatement of ACMs, including non-friable ACMs, must be performed by a Michigan licensed, certified and registered asbestos abatement contractor in accordance with state and federal Occupational Safety and Health Administration (OSHA) and local air quality management regulations. Lead-based paint may be present on the site and is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. LBP generally does not pose a health threat unless particles are disturbed, become airborne and are inhaled or ingested. Contractors and their employers that will be disturbing the building during demolition should follow all applicable requirements in the OSHA Lead in Construction Standard. Further testing may be required of debris generated from demolition activities to determine whether the debris should be disposed as hazardous waste under the Resource Conservation and Recovery Act (RCRA) in accordance with 40-CFR Part 261 Subpart C.

RECOMMENDATIONS:

Except for the following items listed below, Section 61.145(c) of the Asbestos NESHAP requires that each owner or operator of a demolition or renovation activity involving RACM remove all such material from a facility being demolished or renovated before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access to the material for subsequent removal.

ACM need not be removed before demolition if it:

(i) Is a Category I non-friable ACM that is not friable.

(ii) Is on a facility component that is encased in concrete or other similarly hard material and is adequately wet whenever exposed during demolition.

(iii) Was not accessible for testing and therefore was not discovered until after demolition began and, as a result of the demolition, cannot be safely removed. If not removed for safety reasons, the exposed RACM and any asbestos-contaminated debris must be treated as asbestos-containing waste material and kept adequately wet at all times until disposed of.

(iv) Is a Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.

Demolition with Roofing Materials in Place is covered under the NESHAP regulations (40 CFR Part 61 Subpart M).

Page 32: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

4

Roofing materials were generally not tested during this inspection and therefore the roofing material should be assumed to be Category I asbestos-containing roofing materials. Since demolition activities do not include sanding, grinding, cutting, or abrading, Category I asbestos-containing roofing materials not in poor condition and not friable are not considered RACM and are allowed to remain in place during demolition. If the asbestos-containing roofing material is not in poor condition and is not friable, it may be disposed of in a landfill which accepts ordinary demolition waste.

The asbestos-containing roofing material may not be ground up for recycling into other products. In addition, contractors should ensure they follow all OSHA regulations pertaining to demolition of Category I ACM materials. Category I or II nonfriable ACM that is not subject to 61.150(a)(3) would still have to be disposed of in a landfill that accepts building debris, in a landfill that operates in accordance with 61.154, or at a facility that operates in accordance with 61.155. Qualified Abatement Services, Inc. recommends:

A licensed asbestos abatement company should remove the following materials prior to demolition per NESHAP regulations: 1. Windows with asbestos glazing should be removed intact with frame and disposed of as

asbestos waste. LIMITATIONS: The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during Qualified Abatement Services, Inc. Asbestos Containing Material and Hazardous Materials Survey of the vacant above-referenced residential property located in Detroit, Michigan. Any conditions or materials that could not be visually identified through limited destructive sampling were not inspected and may differ from those conditions or materials noted. The user of this report should keep in mind that conditions may change with time and observations made by Qualified Abatement Services, Inc. at the time of the Site reconnaissance may not be consistent with future observations made by others. Additional materials may be encountered during the demolition process and may require further sampling to determine disposal criteria. The report is designed to aid the building owner, architect, construction manager, general contractors, and potential asbestos abatement contractors in locating asbestos building materials to be removed prior to demolition activities.

Page 33: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

5

Under no circumstances is the report to be utilized as a bidding document or as a project specification document. Contractors bidding the demolition of this Site should field verify project information. Qualified Abatement Services, Inc. appreciates the opportunity to be of service to The Michigan Land Bank on this project. In the meantime if you have questions regarding the information in this report or if we can be of further assistance do not hesitate to contact the undersigned at (313) 361-6003 Sincerely, QUALIFIED ABATEMENT SERVICES, INC.

Thomas B. Ross Project Manager

Attachments

Page 34: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

APPENDIX A

LABORATORY ANALYTICAL RESULTS AND CHAIN OF CUSTODY FORMS

Page 35: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Location:

Layer:

Date Reported:

1-ES-A

Project: 2423 Norman

1

Report To:

1of

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB

11/14/12

Lab ID #:

11/08/1211/09/1211/14/12

12-43349Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Appearance:

Sample Information Asbestos Type/Percent Non-Asbestos

Cust. #: Other - 60%43349 - 01 Cellulose - 40%

No Asbestos ObservedNOAsbestos Present:

black,fibrous,nonhomogenous

Material: Exterior Siding Asphalt

Location:

Layer:

Location:

Layer: black,fibrous,nonhomogenous

No Asbestos Observed

No Asbestos Observed

Appearance: black,fibrous,nonhomogenous1

Asbestos Present: Lab ID #:

Appearance:

1-ES-BCellulose - 50%Other - 50%

Lab ID #: Cust. #:

43349 - 02

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

1

Exterior Siding Asphalt

of

1

Exterior Siding Asphalt1-ES-C

Material:

43349 - 03 Cellulose - 50%

Asbestos Present: NO

Material: Cust. #: Other - 50%

NO

For Layered Samples, each component will be analyzed and reported separately.

of 1

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 1 of 6

Page 36: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2423 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB

11/14/12

11/08/1211/09/1211/14/12

12-43349Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

Other - 100%

Sample Information Asbestos Type/Percent Non-Asbestos

NO

Appearance:

Cust. #: Material: Stack Cement

Lab ID #: 2-SC-A No Asbestos Observed43349 - 04 Asbestos Present:

1 of 1grey,nonfibrous,nonhomogenous

Location:

Layer:

Location:

Layer:

Chrysotile - 1.75%

1 of

3-WG-BLab ID #: Cust. #:

Asbestos Present: YES

Material: Window Glaze3-WG-A

Other - 98.25%Lab ID #: Cust. #:

43349 - 05

Appearance: white,fibrous,nonhomogenousPOINT COUNT RESULT

1

NOT ANALYZED

43349 - 06 Asbestos Present:

Appearance:

For Layered Samples, each component will be analyzed and reported separately.

of

Material: Window Glaze

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 2 of 6

Page 37: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2423 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB

11/14/12

11/08/1211/09/1211/14/12

12-43349Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

43349 - 07 Asbestos Present:

Sample Information Asbestos Type/Percent Non-Asbestos

Material: Window GlazeCust. #: 3-WG-CLab ID #:

NOT ANALYZEDAppearance:

of

Location:

Layer:

Location:

Layer:

Cust. #: 4-FT-ALab ID #:

Asbestos Present: NO Other - 100%

NVLAP Lab Code 102118-0

No Asbestos ObservedLab ID #: 43349 - 09

Material: 1x1 Beige/Grey Floor Tile

Asbestos Present: NO Other - 100%No Asbestos Observed

43349 - 08

Appearance: white,nonfibrous,homogenous1 of 1

Cust. #: 4-FT-BMaterial: 1x1 Beige/Grey Floor Tile

2Appearance: white,nonfibrous,homogenous

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

1 of

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 3 of 6

Page 38: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2423 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB

11/14/12

11/08/1211/09/1211/14/12

12-43349Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

Lab ID #: 43349 - 09a

Appearance: clear,nonfibrous,homogenous

Material: Mastic

Asbestos Present: Other - 100%Cust. #: 4-FT-B No Asbestos Observed

NO

2 of 2

Location:

Layer:

Location:

Layer:

Lab ID #: 43349 - 10 Asbestos Present: NO Other - 100%

Material: 1x1 Beige/Grey Floor TileCust. #: 4-FT-C No Asbestos Observed

1 of 2Appearance: grey,nonfibrous,homogenous

Lab ID #: 43349 - 10a Asbestos Present: NO Other - 100%

Material: MasticCust. #: 4-FT-C No Asbestos Observed

of 2Appearance: clear,nonfibrous,homogenous

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

2

NVLAP Lab Code 102118-0

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 4 of 6

Page 39: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2423 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB

11/14/12

11/08/1211/09/1211/14/12

12-43349Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer:

PlasterCust. #: 5-PL-A

Appearance: grey,nonfibrous,homogenous2nd FL Bedroom

Material: No Asbestos Observed

1 of 2

Sample Information Asbestos Type/Percent Non-Asbestos

43349 - 11 Other - 100%Lab ID #: Asbestos Present: NO

Location:

Layer:

Location:

Layer:

NVLAP Lab Code 102118-0

clear,nonfibrous,homogenousAppearance:

Cust. #: 5-PL-A

2nd FL Bedroom

No Asbestos ObservedMaterial: Mortar

Lab ID #: Asbestos Present: 43349 - 11a NO Other - 100%

NO Other - 100%

2 of 2

Lab ID #: 43349 - 12 Asbestos Present: Cust. #: 5-PL-B No Asbestos ObservedMaterial: Plaster

2nd FL Living Room

of 1

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

Appearance: grey,nonfibrous,homogenous

Robert T. Letarte Jr., Laboratory Director

1

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 5 of 6

Page 40: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Date Reported:

Project: 2423 Norman

Report To:

Qualified Abatement Services

ARI Report # Date Collected: Date Received: Date Analyzed:

Project # 12-120 MLB

11/14/12

11/08/1211/09/1211/14/12

12-43349Mr. Thomas B. Ross

1935 McGraw St.Detroit, MI 48208

Location:

Layer: 1 of 1

2nd FL Dining Room POINT COUNT RESULTAppearance: grey,fibrous,nonhomogenous

Cust. #: 5-PL-C Chrysotile - TraceMaterial: Plaster

Sample Information Asbestos Type/Percent Non-Asbestos

Lab ID #: 43349 - 13 Asbestos Present: NO Other - 100%

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1 of 1Appearance: grey,fibrous,nonhomogenous

Material: PlasterBedroom

NO Cellulose - 2%Cust. #: 5-PL-E No Asbestos Observed Other - 98%Lab ID #: 43349 - 15 Asbestos Present:

1 of 1Appearance: grey,nonfibrous,homogenous

Material: PlasterKitchen

NO Other - 100%Cust. #: 5-PL-D No Asbestos ObservedLab ID #: 43349 - 14 Asbestos Present:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 6 of 6

Page 41: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing
Page 42: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

Qualified Abatement Services, Inc.

1935 McGraw Street, Detroit, MI 48208 Phone: 313/361-6003 Fax: 313/361-6143

APPENDIX B

SITE PHOTOGRAPHS

Page 43: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2423 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of the Front of 2423 Norman Street

View of the Side of 2423 Norman Street

Page 44: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2423 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of the Side of 2423 Norman Street

View of the Back of 2423 Norman Street

Page 45: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2423 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Garage

View of Debris throughout the House

Page 46: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2423 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Tires in Garage

View of Computer Monitors in Basement

Page 47: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2423 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Television and Paints in Basement

View of Televisions on 2nd Floor

Page 48: ASBESTOS CONTAINING MATERIAL SURVEY Vacant Former ... · floor tiles containing

ASBESTOS CONTAINING MATERIAL SURVEY VACANT RESIDENTIAL PROPERTY

2423 NORMAN STREET DETROIT, MICHIGAN

Project No. 12-120 Qualified Abatement Services, Inc.

View of Television and Computer Equipment