asbestos assessment - toronto catholic district school board · toronto catholic district school...

52
© 2017 Pinchin Ltd. Asbestos Assessment St. Joseph’s College Catholic Secondary School 74 Wellesley Street West, Toronto, Ontario Prepared for: Toronto Catholic District School Board 80 Sheppard Avenue East Toronto, Ontario, M2N 6E8 Attention: Kathleen Wilson, CHSC, CRSP Safety Officer, Accident Prevention April 19, 2017 Pinchin File: 201408

Upload: others

Post on 08-Oct-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

© 2017 Pinchin Ltd.

Asbestos Assessment St. Joseph’s College Catholic Secondary School 74 Wellesley Street West, Toronto, Ontario Prepared for:

Toronto Catholic District School Board 80 Sheppard Avenue East Toronto, Ontario, M2N 6E8

Attention: Kathleen Wilson, CHSC, CRSP Safety Officer, Accident Prevention

April 19, 2017

Pinchin File: 201408

Page 2: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page i

Issued to: Contact: Issued on: Pinchin File: Issuing Office: Primary Contact:

Toronto Catholic District School Board Kathleen Wilson, CHSC, CRSP Safety Officer, Accident Prevention April 19, 2017 201408 50 Wellington Street East, Suite 200, Toronto, ON M5E 1C8 Victoria Kosuta, Senior Project Manager, 416.368.6555 Ext. 1909

Author: Mike Horobin Senior Project Technologist 416.368.6555 Ext. 1917 [email protected]

Reviewer: Victoria Kosuta B.Sc. Senior Project Manager 416.368.6555 Ext. 1909 [email protected]

Reviewer: Scott Cryer, P.Geo. Operations Manager 905.363.1311 [email protected]

Page 3: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page ii

EXECUTIVE SUMMARY

Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos

building materials assessment of St. Joseph’s College Catholic Secondary School located at 74 Wellesley

Street West, Toronto, Ontario. The assessment was performed on March 16, 2017.

The objectives of the assessment were to document the locations of asbestos building materials, evaluate

their condition and develop corrective action plans as required for the purposes of long term

management. The results of this assessment are not intended for construction, renovation, demolition or

project tendering purposes.

The assessed area consisted of the entire building with the exception of the previous living quarters, Old

Sister Bedrooms located on the 5th, 6th and 7th Floors. The assessed area is outlined in the drawings in

Appendix I.

SUMMARY OF FINDINGS

Asbestos-containing materials (ACM) were confirmed to be present as follows:

• Fibrous sprayed fireproofing (grey in colour) , is present on structural steel beams

throughout the School.

• Parging cement, is present on the hot water tank in the Basement Mechanical Room 120.

• Parging cement, is present on fitting on various pipe systems throughout the School.

• Perforated asbestos cement, Transite Panels, are present as a wall covering in various

locations within the School.

• Transite panels, are present as soffits at the entrances to the School.

• Various 9” x 9” vinyl floor tiles and associated mastic.

• Mastic, associated with various non-asbestos 12” x 12” vinyl floor tiles.

• Interior grey window caulking.

• Interior grey door caulking.

• Exterior grey window caulking.

• Black tar, is present on wood strapping within the dividing walls on the 5th Floor.

Page 4: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page iii

SUMMARY OF RECOMMENDATIONS

The following is a summary of significant recommendations; refer to the body of the report for detailed

recommendations:

1. Perform a reassessment of asbestos materials on an annual basis;

2. Perform a pre-construction assessment and remove all ACM prior to alteration or

maintenance work or if ACM may be disturbed by the work;

3. Follow appropriate safe work procedures when handling or disturbing asbestos;

4. Refer to Section 4.0 of this report for detailed recommendations regarding administrative

and remedial actions.

This Executive Summary is subject to the same standard limitations as contained in the report and must be read in conjunction with the entire report.

Page 5: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page iv

TABLE OF CONTENTS

1.0 INTRODUCTION AND SCOPE ....................................................................................................... 1

1.1 Scope of Assessment ........................................................................................................... 1

2.0 BACKGROUND INFORMATION ..................................................................................................... 1

2.1 Building Description .............................................................................................................. 1 2.2 Existing Reports.................................................................................................................... 2

3.0 FINDINGS ........................................................................................................................................ 2

3.1 Suspect Building Materials Not Found ................................................................................. 2 3.2 Spray-Applied Fireproofing and Thermal Insulation ............................................................. 3 3.3 Thermal Systems Insulation (TSI) ........................................................................................ 4 3.4 Acoustic Ceiling Tiles ........................................................................................................... 7 3.5 Plaster ................................................................................................................................... 8 3.6 Drywall Joint Compound ....................................................................................................... 8 3.7 Asbestos Cement Products (Transite) ................................................................................. 8 3.8 Vinyl Floor Tile and Mastic ................................................................................................... 9 3.9 Levelling Compound ........................................................................................................... 11 3.10 Caulking .............................................................................................................................. 12 3.11 Presumed Asbestos Materials ............................................................................................ 12

4.0 RECOMMENDATIONS .................................................................................................................. 13

4.1 General ............................................................................................................................... 13 4.2 On-going Management and Maintenance .......................................................................... 13

5.0 TERMS AND LIMITATIONS .......................................................................................................... 13

6.0 REFERENCES ............................................................................................................................... 14

APPENDICES

APPENDIX I Drawings

APPENDIX II Asbestos Analytical Certificates

APPENDIX III Methodology

APPENDIX IV Photographs

Page 6: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 1 of 14

1.0 INTRODUCTION AND SCOPE

Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos

building materials assessment of St. Joseph’s College Catholic Secondary School, located at 74

Wellesley Street West, Toronto, Ontario.

The assessment was performed by Mike Horobin, Senior Project Technologist on March 16, 2017. The

surveyor was unaccompanied during the assessment. The building was vacant at the time of the

assessment.

The objectives of the assessment were to document the locations of asbestos building materials, evaluate

their condition and develop corrective action plans as required. This assessment is only to be used for the

purposes of long term management and routine maintenance. The results of this assessment are not to

be used for construction, renovation, demolition or project tendering purposes.

1.1 Scope of Assessment

The assessment was performed to establish the location and type of asbestos building materials

incorporated in the structure(s) and its finishes. The assessed area consisted of all parts of the building

with the exception of the previous living quarters Old Sister Bedrooms located on the 5th, 6th and 7th

Floors. The assessed area is outlined in the drawings in Appendix I.

2.0 BACKGROUND INFORMATION

2.1 Building Description

Item Details

Building Use Catholic Secondary School

Number of Floors/Levels 6 stories plus 1 below grade

Total Area of Building (Square Feet) 103,491

Year of Construction, 1960s

Structure Structural steel and concrete

Exterior Cladding Masonry

HVAC Boiler and hot water heating to radiators

Roof Built-up – not assessed

Page 7: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 2 of 14

Item Details

Flooring Terrazzo, ceramic tiles, vinyl floor tiles, carpet and concrete

Interior Walls Drywall, concrete block and plaster

Ceilings Drywall, plaster and acoustic ceiling tiles

2.2 Existing Reports

Pinchin was provided with and instructed to rely upon, the following reports:

• “Final Report, Asbestos Containing Building Material Assessment, St. Joseph College, 74

Wellesley St. W, Toronto, Ontario” dated October 26, 2007 by Jacques Whitford (Project

Number 1025760).

• “Pre-Construction Designated Substance and Hazardous Materials Assessment, 5th Floor

(East Corridor, Room 449A, Room 450A, Room 451A, Library and Presentation Room-

Chapel) – St. Joseph’s College, 74 Wellesley Street West, Toronto, ON” dated August 5,

2009 by Jacques Whitford Stantec Limited (Project Number 1025760.05).

• “Designated Substance and Hazardous Building Materials Survey, Window and Door

Replacement Project, St Joseph College Catholic School, 74 Wellesley Street West,

Toronto, Ontario” dated May 30, 2013 by Decommissioning Consulting Services Limited

(Project Number 701877-000).

• “Memorandum” dated February 13, 2013 by Decommissioning Consulting Services

Limited (Project 701210-266).

3.0 FINDINGS

Previous sampling was conducted within in the building during previous assessments. Previous samples

collected are labelled “Lab Certificate ID #- AXXXXA-C”. Samples collected during this assessment are

labelled without the Lab Certificate ID AXXXXA-C Additional photos of asbestos-containing materials

(ACM) and non-asbestos materials are present in the Photograph Appendix IV.

3.1 Suspect Building Materials Not Found

The following types of building materials may historically contain asbestos but were not observed in the

building and are not discussed in the report findings:

• Texture finishes (acoustic/decorative);

• Vinyl sheet flooring;

Page 8: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 3 of 14

3.2 Spray-Applied Fireproofing and Thermal Insulation

Sprayed grey (fibrous) fireproofing, containing amosite asbestos, is present on structural steel beams, in

the School (previously sampled 040724014-514-BS19A-G). The total affected floor area is approximately

50,000 square feet. Sprayed fireproofing is friable and is in good condition.

Non-asbestos cementitious grey sprayed fireproofing is present on the structural steel beams throughout

1st Floor Gymnasium within the School (previously sampled 551300743 – 1A-FP, 1B-FP & 1C-FP and

samples A0009A-C).

Non-asbestos fibrous green sprayed fireproofing is present on the structural steel beams throughout on

top of the asbestos-containing grey fireproofing throughout the School (previously sampled 040724014-

514-BS-17A-G).Blue sprayed fireproofing is present on the structural steel beams throughout on top of

the asbestos-containing grey fireproofing throughout the School. The blue fireproofing was not sampled

as it is historically known to be non-asbestos.

Dust or fireproofing within ducts, fan units etc. was not sampled. As per O.Reg. 278/05 (Section 12 (4) 3),

ducts in a building with asbestos-containing sprayed fireproofing are considered to be asbestos-

contaminated in the absence of sampling within the duct. In areas where asbestos-containing sprayed

fireproofing is present, assume the ducts to have asbestos-containing fireproofing or associated dust

present within the ducts.

Asbestos-containing grey fibrous sprayed fireproofing.

Non-asbestos green fireproofing.

Non-asbetsos grey cemntitious sprayed fireproofing.

Non-asbestos blue sprayed fireproofing.

Page 9: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 4 of 14

3.3 Thermal Systems Insulation (TSI)

3.3.1 Pipe Insulation

Parging cement, containing chrysotile asbestos, is present on pipe fittings (elbows, valves, tees, hangers

etc.) on steam, domestic water and drain pipe systems (previously sampled 2740-514-05 from the SAP

Inventory). Parging cement is a friable insulation, jacketed with canvas and is in good condition.

Remaining pipes are either uninsulated or insulated with non-asbestos fibreglass.

Pipes insulated with friable asbestos insulations may be present in inaccessible spaces such as above

solid ceilings, in chases, in column enclosures and within shafts.

Asbestos-containing pipe insulations are present in the following location, quantity, and condition:

Pipe System, Type Location Asbestos Type Total Quantity Quantity Damaged

Steam, parging cement on pipe fittings

Mechanical Room 120 Chrysotile 17 fittings 0

Domestic water, parging cement on pipe fittings

Mechanical Room 120 Chrysotile 21 fittings 0

Drain, parging cement on pipe fittings

Mechanical Room 120 Chrysotile 12 fittings 0

Domestic water, parging cement on pipe fittings

Storage Room 124 Chrysotile 50 fittings 0

Domestic water, parging cement on pipe fittings

Room 107 Chrysotile 30 fittings 0

Domestic water, parging cement on pipe fittings

5th Floor Corridor (Old Sisters Bedrooms) above second drywall ceiling

Chrysotile Presumed 30-45 fittings 0 fitings

Domestic water, parging cement on pipe fittings

6th Floor Corridor Chrysotile 30 fittings 0

Page 10: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 5 of 14

Pipe System, Type Location Asbestos Type Total Quantity Quantity Damaged

Domestic water, parging cement on pipe fittings

7th Floor Corridor Chrysotile 30 fittings 0

Asbestos-containing parging cement on pipe fittings.

Asbestos-containing parging cement on pipe fittings.

Non-asbetsos fibreglass pipe insultion.

3.3.2 Duct Insulation

Ducts were observed to be both uninsulated and insulated with non-asbestos fibreglass and jacketed with

either canvas or foil.

Vibration dampeners within the Mechanical Rooms in the School are presumed to contain asbestos.

Non-asbestos fibreglass duct insulation.

Uninsulated ductwork.

Page 11: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 6 of 14

Preusmed asbetsos-containing vibration dampeners.

3.3.3 Mechanical Equipment Insulation

Parging cement, containing chrysotile asbestos, is present on the hot water tank in Mechanical Room 120

(previously sampled 514 RM.120 from the SAP Inventory). Parging cement is a friable insulation, jacketed

with canvas and is in good condition. There is approximately 150 square feet of asbestos-containing

insulation.

Remaining mechanical equipment is either uninsulated or insulated with non-asbestos fibreglass.

Non-asbestos fibreglass on a water tank.

Asbestos-containing parging cement on the hot water tank.

Uninsulated boiler.

Page 12: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 7 of 14

3.4 Acoustic Ceiling Tiles

Seven distinct types of acoustic ceiling tile are present in the assessed area, as follows:

Size, Type, Pattern Locations (Quantity in Square Feet)

Sample Number or Date Code Asbestos Type

ACT-01 1’ x 1’ , glue-on fissures

Ceilings in Room 121, 311, 312, 313, 515 and 509

Walls of Room 109, 302, 303, 304, 305, 306, 307, 308, 309, 310, 311, 312, 313, 402, 403, 404, 405, 406, 409, 410, 411, 412, 414, 416, 417 and Stairwells throughout

Previously sampled 040724014 514-BS-14A-C

None

ACT-02 24” x 48”, lay-in fleck and pinhole Room 506 and 507 Dated 2009 None

ACT-03 24” x 48”, lay-in pockmark and pinhole Room 216 and 506 Dated 2013 None

ACT-04 24” x 48” large fissure and pinhole

Room 107, 216, 5th Floor Corridor, 6th Floor Corridor and 7th Floor Corridor

Previously sampled 040724014 514-BS-12A-C

None

ACT-05 24” x 48”, lay-in fissures and pinhole

Chapel Room 217, 5th Floor Corridor, Room 510, 511 and 503

Previously sampled 040724014 514-BS-13A-C

None

ACT-06 24” x 48”, lay-in fissures lengthwise

Various locations within the School A0001A-C None

ACT-07 1’ x 1’, splined Room 112 and 515 A0010A-C None

.

Brown mastic, associated with the 1’ x 1’ glue-on acoustic ceiling tiles was sampled (samples A0008A-C)

and was found to be non-asbestos.

Page 13: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 8 of 14

Non-asbestos ACT-01.

Non-asbestos ACT-02.

Refer to additional photographs in Appendix IV.

3.5 Plaster

Plaster is present on walls and ceilings in the School. Plaster does not contain asbestos (previously

sampled 040724014 514-BS-15A-G and 040919461 5F-BS-02A-E).

3.6 Drywall Joint Compound

Drywall (gypsum board) and drywall joint compound is present as a wall finish on the 5th Floor. A total of

three samples of drywall joint compound were collected (samples A0005A-C) and five samples were

previously collected (samples 040919461 5F-BS-05A-E) and it was found that all samples do not contain

asbestos. Therefore, drywall joint compound present on drywall finishes should be considered to be non-

asbestos.

3.7 Asbestos Cement Products (Transite)

Perforated Transite board, containing amosite asbestos, (previously sampled 040724014 514-BS-22A-C)

is present as a wall covering in Corridor Storage Closets on the 3rd and 4th Floors, the old Telephone nook

on the 2nd Floor, and on cabinets in Room 413 and 415. There is approximately 25 square feet of

perforated Transite board present in each location.

Transite boards, visually identified to contain asbestos, are present in the fume hoods in Room 416.

There is approximately 25 square feet of Transite sheets present.

Transite board, containing chrysotile asbestos (previously sampled 551302871 2nd Stair A-CB-1A) is

present as a soffit board at the entrances to the school. There is approximately 25 square feet of Transite

board present at the four Entrances to the building.

Transite is a non-friable material and all Transite was observed to be in good condition.

Page 14: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 9 of 14

Asbestos-containing perforated Transite boards.

Asbestos-containing perforated Transite boards.

Asbestos-containing Transite board in the fume hood.

Asbestos-containing Transite board on the exterior soffit.

3.8 Vinyl Floor Tile and Mastic

Vinyl floor tiles and mastic are present as follows:

Size, Pattern, Colour Locations (Quantity)

Sample Number (tile)

Sample Number (mastic)

Asbestos Type (tile)

Asbestos Type (mastic)

VFT-01 12” x 12’ beige mottled

Room 107, 211, 313, 313A, 506, 507, 509, 510, 511, 5TH Floor Corridor

040724014 514-BS-07A-C

A0011A-C None None

VFT-02 9” x 9” beige marble

Room 512, 513, 514, 515, 5TH Floor Corridor, 502, 511, 801

040724014 514-BS-08A-C

A0002A-C None None

VFT-03 9” x 9” grey with white streaks Room 511

040724014 514-BS-90A-C

A0012A-C Chrysotile Chrysotile

VFT-04 12” x 12” grey mottled

Room 209, 311, 408, 409, 503 A0003A-C A0003A-C None None

VFT-05 12” x 12’ pink Room 502A A0004A-C A0004A-C None None

Page 15: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 10 of 14

Size, Pattern, Colour Locations (Quantity)

Sample Number (tile)

Sample Number (mastic)

Asbestos Type (tile)

Asbestos Type (mastic)

with blue flecks

VFT-06 9” x 9” grey with white and black streaks

Room 109B, 109C, 109D, 116, 117, 118, 806A

040724014 514-BS04A-C

A0006A-C Chrysotile None

VFT-07 9” x 9” beige with grey and white streaks

Room 403, 404 040724014 514-BS-03A-C

A0007A-C Chrysotile Chrysotile

VFT-08 12” x 12” brown with brown and beige flecks

Room 207, 302, 303, 306, 307, 402, 405, 412, 417

Installed 2015

Installed 2015

Presumed non-asbestos

Presumed non-asbestos

VFT-09 12” x 12” beige with brown flecks

Room 102, 103, 104, 121A, 121B, 121C, 121D, 121E, 121G, 121H, 122, 214D, 305, 406, 413, 414, 415, 416

Installed 2015

Installed 2015

Presumed non-asbestos

Presumed non-asbestos

VFT-10 12” x 12’ grey with white flecks

Room 308, 309, 310, 312, 410, 411 A0013A-C A0013A-C None Chrysotile

VFT-11 12” x 12” white with black flecks Room 311

040724014514-BS-02A-C

A0014A-C None None

VFT-12 12” x 12” blue with red and blue flecks

Room 212C A0015A-C A0015A-C None Chrysotile

VFT-13 12” x 12” blue with white and blue flecks

Room 212, 212A A0016A-C A0016A-C None Chrysotile

VFT-14 12” x 12” pink mottled Room 212, 212A

040724014 514-BS-10A-C & A0017A-C

A0017A-C None None

VFT-15 12” x 12” white with large black flecks

Room 204, 204A, 204B, 204C, 204D, 204E, 204F, 205, 205A, 205B, 205C, 206, 206B, 206C, 206D, 206E

A0018A-C A0018A-C None None

Page 16: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 11 of 14

Size, Pattern, Colour Locations (Quantity)

Sample Number (tile)

Sample Number (mastic)

Asbestos Type (tile)

Asbestos Type (mastic)

VFT-16 12” x 12” brown and beige mottled

Room 206A 040724014 514-BA-05A-C

A0019A-C None Chrysotile

VFT-17 12” x 12” beige with black specks

Room 105, 123 A0020A-C A0020A-C None Chrysotile

VFT-18 9” x 9” brown with beige and brown streaks

Room 104, 040724014 514-BS-01A-C

A0021A-C Chrysotile Chrysotile

The vinyl floor tiles and mastic are non-friable and are in good condition.

Vinyl floor tiles which were presumed to be non-asbestos were done so based on historical knowledge of

the date of installation as described by the client.

If either the vinyl floor tile or the mastic contains asbestos, the composite of the materials are considered

an asbestos-containing material.

In areas of the building where mastic was not sampled and analyzed, it is presumed to contain asbestos

unless further sampling proves otherwise.

Non-asbestos VFT-01.

Non-asbestos VFT-02.

Refer to additional photographs in Appendix IV.

3.9 Levelling Compound

Two samples of levelling compound were found in the vinyl floor tiles samples collected during the

assessment. Both samples were found to be non-asbestos. Additional samples of levelling compound

are required to prove that the material is non-asbestos.

Page 17: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 12 of 14

Levelling compound is often used in random and isolated areas and without removing all flooring may not

always be detected.

3.10 Caulking

Interior hard grey caulking along windows contains chrysotile asbestos (previously sampled 551302871

212A-CLK-1A). Caulking is non-friable and is in good condition.

Grey caulking along door contains chrysotile asbestos (previously sampled 551302871 2nd Stair B-CLK-

2A). Caulking is non-friable and is in good condition.

Exterior grey caulking along windows contains chrysotile asbestos (previously sampled 551302871 305-

CLK-8A). Caulking is non-friable and is in good condition.

Remaining exterior and interior caulking is presumed to contain asbestos until further sampling proves

otherwise.

3.11 Presumed Asbestos Materials

A number of materials which might contain asbestos were not sampled during our assessment due to

limitations in scope and methodology. Where present, these materials must be presumed to be an

asbestos material and are best sampled during project planning and preparation of contract documents

for their removal. Materials presumed to contain asbestos include:

• roofing, felts and tar

• concrete floor levelling compound

• vinyl floor tiles mastic

• elevator and lift brakes

• electrical components or wiring within control centers, breakers, motors or lights,

insulation on wiring

• moulded plastic components (laboratory bench tops)

• vermiculite in concrete block wall cavities

• adhesives and duct mastics

• caulking

• fibre reinforced paints and coatings

• paper products under wood flooring or metal or slate roofing

• mechanical packing, ropes and gaskets

Page 18: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 13 of 14

• fire resistant doors or metal clad finishes

4.0 RECOMMENDATIONS

4.1 General

Perform a detailed intrusive assessment prior to building renovation or demolition operations. The

assessment should include destructive testing (i.e. coring and/or removal of building finishes and

components), and sampling of other hazardous materials (lead, mercury, PCBs, mould, etc.) and

materials not tested in this study (e.g. roofing materials, caulking, mastics).

4.2 On-going Management and Maintenance

The following recommendations are made regarding on-going management and maintenance work

involving the asbestos materials identified.

4.2.1 Asbestos

Perform a reassessment of asbestos materials on an annual basis. The next re-assessment of ACM

should be performed prior to March 2018 to remain in compliance.

Remove all ACM prior to alteration or maintenance work or if ACM may be disturbed by the work. Follow

appropriate asbestos precautions for the classification of work being performed.

Update the asbestos inventory report upon completion of any abatement and removal of ACM.

5.0 TERMS AND LIMITATIONS

This work was performed subject to the Terms and Limitations presented or referenced in the proposal for

this project.

Information provided by Pinchin is intended for Client use only. Pinchin will not provide results or

information to any party unless disclosure by Pinchin is required by law. Any use by a third party of

reports or documents authored by Pinchin or any reliance by a third party on or decisions made by a third

party based on the findings described in said documents, is the sole responsibility of such third parties.

Pinchin accepts no responsibility for damages suffered by any third party as a result of decisions made or

actions conducted. No other warranties are implied or expressed.

The information provided in this report is partially based upon analysis of available documents, analytical

results, records and drawings, and personal contacts and interviews. In performing the assessment,

Pinchin has relied in good faith on information provided by other individuals noted in this report. Pinchin

has assumed that the documents, analytical results, records and drawings, and information provided by

Page 19: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 St. Joseph’s College Catholic Secondary School, 74 Wellesley Street West, Toronto, Ontario Pinchin File: 201408

Toronto Catholic District School Board

© 2017 Pinchin Ltd. Page 14 of 14

other individuals noted in this report, including information provided in contacts and personal interviews is

factual and accurate. Pinchin accepts no responsibility for any deficiency, misstatement or inaccuracy

contained in this report as a result of negligence, omissions, misinterpretations or fraudulent acts of

persons interviewed or contacted, or contained in reports that were reviewed, and makes no

representation or warranty as to the qualifications of any such persons or the reliability of information or

reports provided by them, whether or not such persons were introduced to the Client by Pinchin.

6.0 REFERENCES

The following legislation and documents were referenced in completing the assessment and this report:

1. Asbestos on Construction Projects and in Buildings and Repair Operations, Ontario

Regulation 278/05.

2. Designated Substances, Ontario Regulation 490/09.

J:\201000s\0201408.000 TCDSB,VariousSites,Haz,AsbAss\Deliverables\74 Wellesley Street West\201408 - Asbestos Assessment - St Joseph's College - 74 Wellesley Street West - TCDSB.docx

Template: Master Report for Asbestos Assessment, Haz, January 16, 2017

Page 20: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

APPENDIX I Drawings

Page 21: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

A0019B

A0019A

A0019C

A0012A

A0020A

A0020B

A0020C

A0012B

A0012C

A0009A A0009C

A0009B

A0021A

A0021B

A0021C

A0008A A0008B A0008C

A0010A

A0010B

A0010CA0011CA0011B

A0011A

NOTE: ASBESTOS-CONTAINING PIPE INSULATIONS ARE PRESUMED TO BE PRESENT ABOVE SOLID CEILINGS.

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

FIRST FLOOR

2017/04/05

JL

MH

201408

1 OF 8

Page 22: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

A0016A

A0016B

A0015A-C

A0016C

A0017A

A0017B

A0017C

A0019A

A0019B

A0019C

A0018A A0018B

A0018C

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

SECOND FLOOR

2017/04/05

JL

MH

201408

2 OF 8

Page 23: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

A0013A

A0013B

A0013C

A0014A

A0014B

A0014C

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

THIRD FLOOR

2017/04/05

JL

MH

201408

3 OF 8

Page 24: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

A0007C

A0007B

A0007A

405 406 407 407 406

409

410

411

412413414

415416417

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

FOURTH FLOOR

2017/04/05

JL

MH

201408

4 OF 8

Page 25: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

A0001B

A0001C

A0001AA0005C

A0004A

A0004B

A0004C

A0003B

A0003A

A0012A-C

A0003C

A0005B

A0005A

A0002A

A0002B

A0002C

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

FIFTH FLOOR

2017/04/05

JL

MH

201408

5 OF 8

Page 26: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

SIXTH FLOOR

2017/04/05

JL

MH

201408

6 OF 8

Page 27: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

ASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

SEVENTH FLOOR

2017/04/05

JL

MH

201408

7 OF 8

Page 28: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

A0006A-CASBESTOS BULK SAMPLE

OUTSIDE ASSESSMENT SCOPE

NOT ALL KNOWN OR SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS MAY BE DEPICTED ON THEDRAWING. REFER TO THE ASBESTOSASSESSMENT REPORT FOR A COMPLETELIST OF KNOWN AND SUSPECTEDASBESTOS-CONTAINING BUILDINGMATERIALS.

LEGEND IS COLOUR DEPENDENT.NON-COLOUR COPIES MAY ALTERINTERPRETATION.

BASE PLAN PROVIDED BY CLIENT.

ASBESTOS-CONTAINING MATERIALS:

VINYL FLOOR TILES

VINYL FLOOR TILES & MASTIC

TRANSITE

PIPE INSULATION

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:NTS

TORONTO CATHOLICDISTRICT SCHOOL

BOARD

JOSEPH'S COLLEGE74 WELLESLEY STREET WEST

TORONTO, ONTARIO

ASEBESTOS BUILDINGMATERIALS ASSESSMENT

EIGHTH FLOOR

2017/04/05

JL

MH

201408

8 OF 8

Page 29: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

APPENDIX II Asbestos Analytical Certificates

Page 30: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0001A

ACT-06 24" x 48" FissuresLengthwise and pinholes -Room 503

GrayFibrousHomogeneous

Ashed1705827PLM_1

Cellulose Fiber Glass

Perlite Other

40% 40%

10% 10%

None DetectedA0001B

ACT-06 24" x 48" FissuresLengthwise and pinholes -Room 503

GrayFibrousHomogeneous

Ashed1705827PLM_2

Cellulose Fiber Glass

Perlite Other

40% 40%

10% 10%

None DetectedA0001C

ACT-06 24" x 48" FissuresLengthwise and pinholes -Room 503

GrayFibrousHomogeneous

Ashed1705827PLM_3

Cellulose Fiber Glass

Perlite Other

40% 40%

10% 10%

None DetectedA0002A

VFT-02 9" x 9" Beige Marble- Room 512 (Mastic OnlyPlease)

felt/mastic

BlackFibrousHomogeneous

Dissolved1705827PLM_4

Cellulose Synthetic Fibers

Other 60% 10%

30%

None DetectedA0002B

VFT-02 9" x 9" Beige Marble- Room 512 (Mastic OnlyPlease)

felt/mastic

BlackFibrousHomogeneous

Dissolved1705827PLM_5

Cellulose Synthetic Fibers

Other 60% 10%

30%

None DetectedA0002C

VFT-02 9" x 9" Beige Marble- Room 512 (Mastic OnlyPlease)

felt/mastic

BlackFibrousHomogeneous

Dissolved1705827PLM_6

Cellulose Synthetic Fibers

Other 60% 10%

30%

None DetectedA0003A - A

VFT-04 12" x 12" Grey withGrey and White Flecks -Room 209

tile

GrayNon FibrousHomogeneous

Dissolved1705827PLM_7

Other 100%

None DetectedA0003A - B

VFT-04 12" x 12" Grey withGrey and White Flecks -Room 209

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_64

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 31: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0003B - A

VFT-04 12" x 12" Grey withGrey and White Flecks -Room 209

tile

GrayNon FibrousHomogeneous

Dissolved1705827PLM_8

Other 100%

None DetectedA0003B - B

VFT-04 12" x 12" Grey withGrey and White Flecks -Room 209

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_65

Other 100%

None DetectedA0003C - A

VFT-04 12" x 12" Grey withGrey and White Flecks -Room 209

tile - ashed

GrayNon FibrousHomogeneous

Ashed1705827PLM_9

Other 100%

None DetectedA0003C - B

VFT-04 12" x 12" Grey withGrey and White Flecks -Room 209

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_66

Other 100%

None DetectedA0004A - A

VFT-05 12" x 12" Pink withBlue Flecks - Room 502A

tile

BeigeNon FibrousHomogeneous

Dissolved1705827PLM_10

Other 100%

None DetectedA0004A - B

VFT-05 12" x 12" Pink withBlue Flecks - Room 502A

mastic

YellowNon FibrousHomogeneous

Dissolved1705827PLM_67

Other 100%

None DetectedA0004B - A

VFT-05 12" x 12" Pink withBlue Flecks - Room 502A

tile

BeigeNon FibrousHomogeneous

Dissolved1705827PLM_11

Other 100%

None DetectedA0004B - B

VFT-05 12" x 12" Pink withBlue Flecks - Room 502A

mastic/leveling compound

Yellow, GrayNon FibrousHeterogeneous

Dissolved, Crushed1705827PLM_68

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 2 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 32: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0004C - A

VFT-05 12" x 12" Pink withBlue Flecks - Room 502A

tile - ashed

BeigeNon FibrousHomogeneous

Ashed1705827PLM_12

Other 100%

None DetectedA0004C - B

VFT-05 12" x 12" Pink withBlue Flecks - Room 502A

mastic/leveling compound

Yellow, GrayNon FibrousHeterogeneous

Dissolved, Crushed1705827PLM_69

Other 100%

None DetectedA0005A

DWJC - 5th Floor CorridorWhiteNon FibrousHomogeneous

Crushed1705827PLM_13

Other 100%

None DetectedA0005B

DWJC - 5th Floor - Room 515WhiteNon FibrousHomogeneous

Crushed1705827PLM_14

Other 100%

None DetectedA0005C

DWJC - 5th Floor - Room501A

WhiteNon FibrousHomogeneous

Crushed1705827PLM_15

Other 100%

None DetectedA0006A

VFT-06 9" x 9" Grey withWhite and Black Streaks -Room 109B (Mastic Only Plea

BlackNon FibrousHomogeneous

Dissolved1705827PLM_16

Other 100%

None DetectedA0006B

VFT-06 9" x 9" Grey withWhite and Black Streaks -Room 109B (Mastic Only Plea

BlackNon FibrousHomogeneous

Dissolved1705827PLM_17

Other 100%

None DetectedA0006C

VFT-06 9" x 9" Grey withWhite and Black Streaks -Room 109B (Mastic Only Plea

BlackNon FibrousHomogeneous

Dissolved1705827PLM_18

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 3 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 33: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

3% Chrysotile

A0007A

VFT-07 9" x 9" Beige withGrey and White Streaks -Room 403 (mastic Only Pleas

BlackNon FibrousHomogeneous

Dissolved1705827PLM_19

Other 97%

Not AnalyzedA0007B

VFT-07 9" x 9" Beige withGrey and White Streaks -Room 403 (mastic Only Pleas

1705827PLM_20

Not AnalyzedA0007C

VFT-07 9" x 9" Beige withGrey and White Streaks -Room 403 (mastic Only Pleas

1705827PLM_21

None DetectedA0008A

Brown Acoustic Ceiling TileMastic - Room 121C

BrownNon FibrousHomogeneous

Dissolved1705827PLM_22

Other 100%

None DetectedA0008B

Brown Acoustic Ceiling TileMastic - Room 121C

BrownNon FibrousHomogeneous

Dissolved1705827PLM_23

Other 100%

None DetectedA0008C

Brown Acoustic Ceiling TileMastic - Room 121B

BrownNon FibrousHomogeneous

Dissolved1705827PLM_24

Other 100%

None DetectedA0009A

Grey Cementitious SprayedFireproofing - Room 123

GrayNon FibrousHeterogeneous

Crushed1705827PLM_25

Other Vermiculite

60% 40%

None DetectedA0009B

Grey Cementitious SprayedFireproofing - Room 123

GrayNon FibrousHeterogeneous

Crushed1705827PLM_26

Other Vermiculite

60% 40%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 4 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 34: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0009C

Grey Cementitious SprayedFireproofing - Room 123

GrayNon FibrousHeterogeneous

Crushed1705827PLM_27

Other Vermiculite

60% 40%

None DetectedA0010A

ACT-07 1' x 1' Pockmark andPinhole - Room 112

GrayFibrousHomogeneous

Ashed1705827PLM_28

Cellulose Fiber Glass

Perlite Other

40% 30%

20% 10%

None DetectedA0010B

ACT-07 1' x 1' Pockmark andPinhole - Room 112

GrayFibrousHomogeneous

Ashed1705827PLM_29

Cellulose Fiber Glass

Perlite Other

40% 30%

20% 10%

None DetectedA0010C

ACT-07 1' x 1' Pockmark andPinhole - Room 112

GrayFibrousHomogeneous

Ashed1705827PLM_30

Cellulose Fiber Glass

Perlite Other

40% 30%

20% 10%

None DetectedA0011A

VFT-01 12" x 12" BeigeMottled - Room 107 (MasticOnly Please)

YellowNon FibrousHomogeneous

Dissolved1705827PLM_31

Other 100%

None DetectedA0011B

VFT-01 12" x 12" BeigeMottled - Room 107 (MasticOnly Please)

YellowNon FibrousHomogeneous

Dissolved1705827PLM_32

Other 100%

None DetectedA0011C

VFT-01 12" x 12" BeigeMottled - Room 107 (MasticOnly Please)

YellowNon FibrousHomogeneous

Dissolved1705827PLM_33

Other 100%

4% Chrysotile

A0012A

VFT-03 9" x 9" Grey withWhite Streaks - Room 511(Mastic Only Please)

BlackNon FibrousHomogeneous

Dissolved1705827PLM_34

Other 96%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 5 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 35: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

Not AnalyzedA0012B

VFT-03 9" x 9" Grey withWhite Streaks - Room 511(Mastic Only Please)

1705827PLM_35

Not AnalyzedA0012C

VFT-03 9" x 9" Grey withWhite Streaks - Room 511(Mastic Only Please)

1705827PLM_36

None DetectedA0013A - A

VFT-10 12" x 12" Grey withWhite Flecks - Room 308

tile

TanNon FibrousHomogeneous

Dissolved1705827PLM_37

Other 100%

3% Chrysotile

A0013A - BVFT-10 12" x 12" Grey withWhite Flecks - Room 308

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_70

Other 97%

None DetectedA0013B - A

VFT-10 12" x 12" Grey withWhite Flecks - Room 308

tile

TanNon FibrousHomogeneous

Dissolved1705827PLM_38

Other 100%

Not AnalyzedA0013B - B

VFT-10 12" x 12" Grey withWhite Flecks - Room 308

mastic1705827PLM_71

None DetectedA0013C - A

VFT-10 12" x 12" Grey withWhite Flecks - Room 308

tile - ashed

TanNon FibrousHomogeneous

Ashed1705827PLM_39

Other 100%

Not AnalyzedA0013C - B

VFT-10 12" x 12" Grey withWhite Flecks - Room 308

mastic1705827PLM_72

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 6 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 36: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0014A

VFT-11 12" x 12" White withBlack Flecks - Room 311(Mastic Only Please)

Black, YellowNon FibrousHeterogeneous

Dissolved1705827PLM_40

Other 100%

None DetectedA0014B

VFT-11 12" x 12" White withBlack Flecks - Room 311(Mastic Only Please)

Black, YellowNon FibrousHeterogeneous

Dissolved1705827PLM_41

Other 100%

None DetectedA0014C

VFT-11 12" x 12" White withBlack Flecks - Room 311(Mastic Only Please)

Black, YellowNon FibrousHeterogeneous

Dissolved1705827PLM_42

Other 100%

None DetectedA0015A - A

VFT-12 12" x 12" Blue withRed and Blue Flecks - Room305

tile

BlueNon FibrousHomogeneous

Dissolved1705827PLM_43

Other 100%

2% Chrysotile

A0015A - B

VFT-12 12" x 12" Blue withRed and Blue Flecks - Room305

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_73

Other 98%

None DetectedA0015B - A

VFT-12 12" x 12" Blue withRed and Blue Flecks - Room305

tile

BlueNon FibrousHomogeneous

Dissolved1705827PLM_44

Other 100%

Not AnalyzedA0015B - B

VFT-12 12" x 12" Blue withRed and Blue Flecks - Room305

mastic1705827PLM_74

None DetectedA0015C - A

VFT-12 12" x 12" Blue withRed and Blue Flecks - Room305

tile - ashed

BlueNon FibrousHomogeneous

Ashed1705827PLM_45

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 7 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 37: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

Not AnalyzedA0015C - B

VFT-12 12" x 12" Blue withRed and Blue Flecks - Room305

mastic1705827PLM_75

None DetectedA0016A - A

VFT-13 12" x 12" Blue withWhite and Blue Flecks - Room212B

tile

BlueNon FibrousHomogeneous

Dissolved1705827PLM_46

Other 100%

3% Chrysotile

A0016A - B

VFT-13 12" x 12" Blue withWhite and Blue Flecks - Room212B

mixed mastics

Black, YellowNon FibrousHeterogeneous

Dissolved1705827PLM_76

Other 97%

None DetectedA0016B - A

VFT-13 12" x 12" Blue withWhite and Blue Flecks - Room212B

tile

BlueNon FibrousHomogeneous

Dissolved1705827PLM_47

Other 100%

Not AnalyzedA0016B - B

VFT-13 12" x 12" Blue withWhite and Blue Flecks - Room212B

mixed mastics1705827PLM_77

None DetectedA0016C - A

VFT-13 12" x 12" Blue withWhite and Blue Flecks - Room212B

tile - ashed

BlueNon FibrousHomogeneous

Ashed1705827PLM_48

Other 100%

Not AnalyzedA0016C - B

VFT-13 12" x 12" Blue withWhite and Blue Flecks - Room212B

mixed mastics1705827PLM_78

None DetectedA0017A - A

VFT-14 12" x 12" PinkMottled - Room 212

tile

PinkNon FibrousHomogeneous

Dissolved1705827PLM_49

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 8 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 38: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0017A - B

VFT-14 12" x 12" PinkMottled - Room 212

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_79

Other 100%

None DetectedA0017B - A

VFT-14 12" x 12" PinkMottled - Room 212

tilr

PinkNon FibrousHomogeneous

Dissolved1705827PLM_50

Other 100%

None DetectedA0017B - B

VFT-14 12" x 12" PinkMottled - Room 212

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_80

Other 100%

None DetectedA0017C - A

VFT-14 12" x 12" PinkMottled - Room 212

tile - ashed

PinkNon FibrousHomogeneous

Ashed1705827PLM_51

Other 100%

None DetectedA0017C - B

VFT-14 12" x 12" PinkMottled - Room 212

mastic

BlackNon FibrousHomogeneous

Dissolved1705827PLM_81

Other 100%

None DetectedA0018A - A

VFT-15 12" x 12" White withLarge Black Flecks - Room204

tile

WhiteNon FibrousHomogeneous

Dissolved1705827PLM_52

Other 100%

None DetectedA0018A - B

VFT-15 12" x 12" White withLarge Black Flecks - Room204

mastic

WhiteNon FibrousHomogeneous

Dissolved1705827PLM_82

Other 100%

None DetectedA0018B - A

VFT-15 12" x 12" White withLarge Black Flecks - Room204

tile

WhiteNon FibrousHomogeneous

Dissolved1705827PLM_53

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 9 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 39: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0018B - B

VFT-15 12" x 12" White withLarge Black Flecks - Room204

mastic

YellowNon FibrousHomogeneous

Dissolved1705827PLM_83

Other 100%

None DetectedA0018C - A

VFT-15 12" x 12" White withLarge Black Flecks - Room204

tile -ashed

WhiteNon FibrousHomogeneous

Ashed1705827PLM_54

Other 100%

None DetectedA0018C - B

VFT-15 12" x 12" White withLarge Black Flecks - Room204

mastic

YellowNon FibrousHomogeneous

Dissolved1705827PLM_84

Other 100%

3% Chrysotile

A0019A

VFT-16 12" x 12" Brown andBeige Mottled - Room 206A(Mastic Only Please)

BlackNon FibrousHomogeneous

Dissolved1705827PLM_55

Other 97%

Not AnalyzedA0019B

VFT-16 12" x 12" Brown andBeige Mottled - Room 206A(Mastic Only Please)

1705827PLM_56

Not AnalyzedA0019C

VFT-16 12" x 12" Brown andBeige Mottled - Room 206A(Mastic Only Please)

1705827PLM_57

None DetectedA0020A - A

VFT-17 12" x 12" Beige withBlack Specks - Room 105

tile

BeigeNon FibrousHomogeneous

Dissolved1705827PLM_58

Other 100%

2% Chrysotile

A0020A - BVFT-17 12" x 12" Beige withBlack Specks - Room 105

mixed mastics

Black, YellowNon FibrousHeterogeneous

Dissolved1705827PLM_85

Other 98%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 10 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 40: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 600/M4-82-020

201408 Toronto Catholic School Board St Joseph's College 74 Wellesley Street WestToronto Ontario

Project:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Mike HorobinAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1705827_PLM

Date Amended: 4/17/2017

Date Reported: 3/24/2017

Date Received: 3/21/2017

Lab Order ID: 1705827

None DetectedA0020B - A

VFT-17 12" x 12" Beige withBlack Specks - Room 105

tile

BeigeNon FibrousHomogeneous

Dissolved1705827PLM_59

Other 100%

Not AnalyzedA0020B - B

VFT-17 12" x 12" Beige withBlack Specks - Room 105

mixed mastics1705827PLM_86

None DetectedA0020C - A

VFT-17 12" x 12" Beige withBlack Specks - Room 105

tile - ashed

BeigeNon FibrousHomogeneous

Ashed1705827PLM_60

Other 100%

Not AnalyzedA0020C - B

VFT-17 12" x 12" Beige withBlack Specks - Room 105

mixed mastics1705827PLM_87

3% Chrysotile

A0021A

VFT-18 9" x 9" Brown withBeige and Brown Streaks -Room 104 (Mastic Only Pleas

BlackNon FibrousHomogeneous

Dissolved1705827PLM_61

Other 97%

Not SubmittedA0021B

VFT-18 9" x 9" Brown withBeige and Brown Streaks -Room 104 (Mastic Only Pleas

1705827PLM_62

Not SubmittedA0021C

VFT-18 9" x 9" Brown withBeige and Brown Streaks -Room 104 (Mastic Only Pleas

1705827PLM_63

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 11 of 11

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (87)

P-F-002 r15 1/15/2018

Page 41: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

APPENDIX III Methodology

Page 42: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment Methodology April 19, 2017 Methodology Appendix Pinchin File: 201408

© 2017 Pinchin Ltd. Page 1 of 3

1.0 GENERAL

Pinchin conducts a room-by-room survey (rooms, corridors, service areas, exterior, etc.) to identify the

asbestos building materials defined by the scope of the work. All work is conducted in accordance with

our own internal Standard Operating Procedures.

Information regarding the location and condition of asbestos building materials encountered and visually

estimated quantities are recorded. The locations of any samples collected are recorded on small-scale

plans.

As-built drawings and previous reports are referenced where provided.

1.1 Scope Limitations

The assessment excludes the following:

• Articles belonging to the owner, tenant or occupant (e.g. stored items, furniture,

appliances, etc.);

• Underground materials or equipment (e.g. vessels, drums, underground storage tanks,

pipes, etc.);

• Building envelope, structural components, inaccessible or concealed materials or other

items where sampling may cause consequential damage to the property.

• Energized systems (e.g. internal boiler components, elevators, mechanical or electrical

components);

• Controlled products (e.g. stored chemicals, operational or process-related substances);

and

• Materials not typically associated with construction (e.g. settled dust, spills, residual

contamination from prior spills, etc.).

The assessment is limited to non-intrusive testing. Concealed spaces such as those above solid ceilings

and within shafts and pipe chases are accessed via existing access panels only Pinchin does not conduct

demolition of walls, solid ceilings, structural items, interior finishes or exterior building finishes, to

determine the presence of concealed materials.

1.2 Detailed Methodology

Pinchin conducts an inspection for the presence of friable and non-friable asbestos-containing materials

(ACM). A friable material is a material that when dry can be crumbled, pulverized or powdered by hand

pressure.

Page 43: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment Methodology April 19, 2017 Methodology Appendix Pinchin File: 201408

© 2017 Pinchin Ltd. Page 2 of 3

A separate set of samples is collected of each type of homogenous material suspected to contain

asbestos. A homogenous material is defined by the US EPA as material that is uniform in texture and

appearance, was installed at one time, and is unlikely to consist of more than one type or formulation of

material. The homogeneous materials are determined by visual examination and available information on

the phases of construction and prior renovations.

Pinchin collects samples at a rate that is in compliance with Table 1 of O.Reg. 278/05.

The sampling strategy is also based on known ban dates and phase out dates of the use of asbestos;

sampling of certain building materials is not conducted after specific construction dates. In addition, to be

conservative, several years past these dates are added to account for some uncertainty in the exact

start/finish date of construction and associated usage of ACM.

In some cases, manufactured products such as asbestos cement pipe are visually identified without

sample confirmation.

Drywall joint compound is sampled at exterior walls, columns or other locations that are unlikely to have

been renovated in an attempt to determine the presence of asbestos in the original drywall compound.

Delineation of asbestos-containing drywall compound from newer, non-asbestos drywall compound is not

conducted.

Flooring mastic or adhesive is sampled and analyzed if present on the underside of flooring samples

(vinyl floor tile and vinyl sheet flooring).

If present, the following materials are presumed to be asbestos-containing and are best sampled

immediately prior to commencing renovation/disturbance:

• roofing, felts and tar

• concrete floor levelling compound

• elevator and lift brakes

• electrical components or wiring within control centers, breakers, motors or lights,

insulation on wiring

• moulded plastic components (laboratory bench tops)

• refractory materials and insulations in boilers, incinerators and stacks

• insulation under metal clad boilers and vessels

• vermiculite in concrete block wall cavities

• adhesives and duct mastics

• caulking

Page 44: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment Methodology April 19, 2017 Methodology Appendix Pinchin File: 201408

© 2017 Pinchin Ltd. Page 3 of 3

• fibre reinforced paints and coatings

• paper products under wood flooring or metal or slate roofing

• soffit and fascia boards at elevated heights

• mechanical packing, ropes and gaskets

• fire resistant doors or metal clad finishes

• exterior cladding

Pinchin submits the bulk samples to a NVLAP accredited laboratory for analysis. The analysis is

performed in accordance with Test Method EPA/600/R-93/116: Method for the Determination of Asbestos

in Bulk Building Materials, July 1993.

In Ontario an ACM is defined as materials containing 0.5% or more asbestos by weight.

The asbestos analysis is completed using a stop positive approach. Only one result meeting the above

regulated criteria is required to determine that a material is asbestos-containing, but all samples must be

analyzed to conclusively determine that a material is non-asbestos. The laboratory stops analyzing

samples from a homogeneous material once a result equal to or greater than the regulated criteria is

detected in any of the samples of that material. All samples of a homogeneous material are analyzed if no

asbestos is detected. In some cases, all samples are analyzed in the sample set regardless of result.

Where building materials are described in the report as non-asbestos, this means that either no asbestos

was detected by the analytical method utilized in any of the multiple samples or, if detected, it is below the

lower limit of an asbestos-containing material in the applicable regulation.

Asbestos materials are evaluated in order to make recommendations regarding remedial work. The

priority for remedial action is based on several factors:

• Friability (friable or non-friable).

• Condition (good, fair, poor, debris).

• Accessibility (ranking from accessible to all building users to inaccessible).

• Visibility (whether the material is obscured by other building components).

• Efficiency of the work (for example, if damaged ACM is being removed in an area, it may

be most practical to remove all ACM in the area even if it is in good condition).

Master Template: Methodology Document for Asbestos Assessment, HAZ, October 18, 2016

Page 45: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

APPENDIX IV Photographs

Page 46: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 1 of 7

Non-asbestos ACT-03.

Non-asbestos ACT-04.

Non-asbestos ACT-05.

Page 47: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 2 of 7

Non-asbestos ACT-06.

Non-asbestos ACT-07.

Non-asbestos brown ceiling tile mastic.

Page 48: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 3 of 7

Asbestos-containing VFT-03.

Non-asbestos VFT-04.

Non-asbestos VFT-05.

Page 49: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 4 of 7

Asbestos-containing VFT-06.

Asbestos-containing VFT-07.

Non-asbestos VFT-08.

Page 50: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 5 of 7

Asbestos-containing VFT-10.

Non-asbestos VFT-11.

Asbestos-containing VFT-12.

Page 51: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 6 of 7

Non-asbestos VFT-13.

Non-asbestos VFT-14.

Non-asbestos VFT-15.

Page 52: Asbestos Assessment - Toronto Catholic District School Board · Toronto Catholic District School Board (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials

Asbestos Assessment April 19, 2017 74 Wellesley Street West Pinchin File: 201408 Toronto Catholic District School Board Appendix IV

© 2017 Pinchin Ltd. Page 7 of 7

Asbestos-containing VFT-18.

J:\201000s\0201408.000 TCDSB,VariousSites,Haz,AsbAss\Deliverables\74 Wellesley Street West\Appendix IV\201408 - 74 Wellesley St W Photo Appendix.docx

Template: Master Photo Appendix, HazMat, February 10, 2016